Table of Contents 56 sections Liability · Copyright · Environmental information · The screenshots in this manual · … ShowHide
Liabilityp.2Copyrightp.2Environmental informationp.2The screenshots in this manualp.2Table of contentsp.3Introductionp.4Notes on this manualp.4Writings in this manualp.5Notes on the symbolsp.5Safety requirementsp.5System requirementsp.6Scope of deliveryp.7Functions of the scannerp.8Chapter I. Installation of the scannerp.10Installation requirementsp.10Hardware requirementsp.10Installing and setting up scannersp.11First, choose a suitable location!p.11Step 1. Unlocking scannerp.11Step 2. Connecting the scanner to your computerp.12Step 3. Installing softwarep.13Step 4. Testing scannersp.14Test flatbed mode:p.15Installation of additional softwarep.15Chapter II. Scanningp.16Preparing documentsp.17Verification of document propertiesp.17Place documentsp.17Use of the flat bedp.17Scanning documentsp.17Scanning with the TWAIN user interfacep.18Scanning within the NewSoft Presto! ImageFolio:p.18Scanning with I.R.I.S. Readiris Pro 10 Corporate Edition:p.19Scanning with Plustek DI Capturep.20Scanning via the control panel or program DocActionp.22Configuration of button settingsp.22Scanning with the keysp.22Chapter III. Maintenance and carep.24Cleaning scannersp.24Cleaning materialsp.24Cleaning the flat bedp.24Cleaning of the document pad and scanning glass:p.25Orienting the scannerp.25The adjustment for the flatbed scan:p.25Energy saving modep.26Locking of the scanner headp.27Always unlocked:p.27Always blocked:p.28Chapter IV. Incident correctionp.29Connection to the scannerp.29Annex A: Technical datap.30Plustek OpticPro A360p.30Annex B: Customer servicep.31Limited guarantee declarationp.31FCC declarationp.32How to reach Plustekp.34
Page 1 of the Plustek A360 user manual — 9 Installation 9 Handling and care
Page 1 · click to enlarge
Page 1
Plustek A360 diagram (page 1)
Fig. 1

9 Installation 9 Handling and care

Page 2 of the Plustek A360 user manual — Liability
Page 2 · click to enlarge
Page 2

© 2008 Plustek Inc. All rights reserved. Copying this document is only permitted with express permission. All trademarks and brand names mentioned in this documentation are the property of each company. Liability

Although every effort has been made to ensure the correctness of the contents of this document, we do not guarantee any errors, omissions or statements in this document of any kind, whether they are omission or statement based on negligence, accident, or other causes. The content of this guide may be changed without prior notice. Copyright

Scanning of certain documents, e.g. B. Checks, banknotes, ID cards, federal bonds or public documents may be prohibited by law and/or subject to criminal prosecution. We recommend that you show yourself responsible and respect copyright when scanning books, magazines, journals and other things. Environmental information

The product is designed and produced to ensure environmentally sound use. We make it important that our products meet global environmental standards. Take disposal according to local regulations. The product packaging can be recycled. Note for disposal Protect your environment too. After termination of use, the device does not belong in household waste. Please use the free return options at the acceptance points in your community. The screenshots in this manual

The screenshots in this guide are about Windows XP. If you are using Windows 2000 or Vista, the screen interfaces look a little different but work in exactly the same way.

Trademark protection

Page 3 of the Plustek A360 user manual — Table of Contents
Page 3 · Contents
Contents

Contents

Liabilityp.2Copyrightp.2Environmental informationp.2The screenshots in this manualp.2Table of contentsp.3Introductionp.4Notes on this manualp.4Writings in this manualp.5Notes on the symbolsp.5Safety requirementsp.5System requirementsp.6Scope of deliveryp.7Functions of the scannerp.8Chapter I. Installation of the scannerp.10Installation requirementsp.10Hardware requirementsp.10Installing and setting up scannersp.11First, choose a suitable location!p.11Step 1. Unlocking scannerp.11Step 2. Connecting the scanner to your computerp.12Step 3. Installing softwarep.13Step 4. Testing scannersp.14Test flatbed mode:p.15Installation of additional softwarep.15Chapter II. Scanningp.16Preparing documentsp.17Verification of document propertiesp.17Place documentsp.17Use of the flat bedp.17Scanning documentsp.17Scanning with the TWAIN user interfacep.18Scanning within the NewSoft Presto! ImageFolio:p.18Scanning with I.R.I.S. Readiris Pro 10 Corporate Edition:p.19Scanning with Plustek DI Capturep.20Scanning via the control panel or program DocActionp.22Configuration of button settingsp.22Scanning with the keysp.22Chapter III. Maintenance and carep.24Cleaning scannersp.24Cleaning materialsp.24Cleaning the flat bedp.24Cleaning of the document pad and scanning glass:p.25Orienting the scannerp.25The adjustment for the flatbed scan:p.25Energy saving modep.26Locking of the scanner headp.27Always unlocked:p.27Always blocked:p.28Chapter IV. Incident correctionp.29Connection to the scannerp.29Annex A: Technical datap.30Plustek OpticPro A360p.30Annex B: Customer servicep.31Limited guarantee declarationp.31FCC declarationp.32How to reach Plustekp.34
Page 4 of the Plustek A360 user manual — H INDICATIONS TO THIS H ANDBUCH
Page 4 · click to enlarge
Page 4

E IMPLEMENTATION

We thank you for choosing us when buying your scanner. With your new scanner, you can handle a variety of daily office tasks professionally, such as reading pictures and texts into your computer.

Like all our products, the scanner has been developed with a view to ease of use and extreme reliability. We stand for this with our good reputation in terms of customer satisfaction. We hope that you will be as satisfied with this product as many other users and therefore also choose us in the future.

H INDICATIONS TO THIS H ANDBUCH

This user manual describes the installation and operation of the scanner in detail and easily understood. It is assumed that you are familiar with Windows Vista, XP or 2000 Professional. If this is not the case, check out your Microsoft Windows guide to help you deal with Windows before using the scanner.

The first sections of this manual describe the scope and system requirements for your computer to use this scanner. Check the completeness of the shipment before you start installing Plustek scanner. If parts are missing or damaged, contact the dealer from whom you purchased the scanner or directly contact customer service at your nearest Plustek office (addresses can be found at the end of this guide).

Chapter I contains information on how to connect the scanner to the computer and install the scan software. Note: The data transmission between the scanner and computer takes place via USB (Universal Serial Bus). If your computer does not support the USB standard, you will need to purchase a USB interface card in order to upgrade it accordingly. If your computer’s motherboard is already USB-capable, you still need the USB ports. This guide assumes that your computer is USB compatible and has a free USB port.

Chapter II describes how to use the scanner.

Chapter III describes how to maintain and clean your scanner.

In Chapter IV, you will find troubleshooting information and the technical data that may be useful to you in solving any problems.

Appendix A contains the specifications of your purchased scanner.

Page 5 of the Plustek A360 user manual — S REGULATIONS OF THE COURT
Page 5 · click to enlarge
Page 5

Appendix B includes our customer service and limited warranty declaration.

S SCRIPTURES IN THIS H ANDBUCH

Fatty fat To display commands, or screen messages are used.

BIG LABEL —Used to highlight important information.

Italics —Represents buttons on your scanner or important clues.

Notes on the symbols

This manual uses the following symbols to highlight specific information:

Shows how you need to proceed exactly in order to avoid injury or accident.

Points out information you should remember and that can help prevent error.

Optional information and guidance.

S REGULATIONS OF THE COURT

Before using the device, read important information to avoid or reduce any risk of injury or damage.

1. The following conditions may result in moisture fogging inside the apparatus which causes a malfunction:

when the device is moved from a cold place to a warm one; after heating up of a cold room; if accommodated in a damp room.

To avoid moisture fogging, proceed as described: i. Seal the device in a plastic bag before moving it to another room. ii. Wait 1-2 hours before you remove the device from your plastic bag.

take out.

Page 6 of the Plustek A360 user manual — S YSTEM REQUIREMENTS
Page 6 · click to enlarge
Page 6
2. Use only the original power supply, electric cable and USB cable that comes with it. When using other power supplies and cables, the scanner may not work.
3. Keep the power connection free if you need to unplug it during unforeseen emergencies.
4. Damaged cables can cause a fire or an electric shock. Avoid twisting, bending or damaging the power cord.
5. Remove the power cord if you are not using it for a long time, e.g. B. overnight or on weekends to avoid the risk of a fire.
6. Do not try to take the scanner apart. There is a risk of electrical shocks. Opening the scanner also leads to loss of warranty.
7. Do not bump or knock on the scan surface. It is very sensitive and could break.
8. Do not expose the scanner to extreme vibrations. Internal components can be damaged as a result.

S YSTEM REQUIREMENTS

z PC with Intel Pentium® IV 2.0 GHz processor or equivalent

Z 512 MB RAM

z 2.0 connection available

z 800 MB hard disk memory

z Graphic card with at least 16 bit color depth

z Operating system: Windows 2000 Professional, Windows XP Home Edition, Windows xp Professional or Windows Vista (equivalent)

For optimal performance, systems with Pentium® IV 3.0 GHz or better processor (or equivalent), 1GB of RAM and 1 GB of free hard disk space are recommended.

1 For scanning or editing large amounts of image data, the requirements may be higher. The specified system requirements are only a guideline. In general, the better the computer (main circuit board, processor, hard drive, RAM, video card), the better results.

z CD-ROM or DVD drive

Page 7 of the Plustek A360 user manual — L LIP CIRCUMFERENCE
Page 7 · click to enlarge
Page 7

L LIP CIRCUMFERENCE

Plustek A360 — L LIP CIRCUMFERENCE diagram (page 7)
Fig. 2
1. Scanner 3
2. USB connection cable
3. Electrical cables
4. Netting
5. Scanner user manual
6. Program and driver CD-ROM

2 Pick up the packaging materials for possible future transports. 3 The illustrations in this manual may differ from their scanner.

Page 8 of the Plustek A360 user manual — F UNCTIONS OF THE S CANNER
Page 8 · click to enlarge
Page 8

F UNCTIONS OF THE S CANNER

Plustek A360 — F UNCTIONS OF THE S CANNER diagram (page 8)
Fig. 3
1. DOCUMENT-ABSELVATION – Keeps the paper in place and protects the glass of the scanner.
2. DOCUMENT POSTER – Keeps the paper in place and improves quality.
3. SCANNER-GLAS – Here you place the objects that you want to scan flatbed.
4. Paper Size Markings – Adjust your paper to this size mark if you want to do the flatbed scanning.
Plustek A360 — F UNCTIONS OF THE S CANNER diagram (page 8)
Fig. 4
Page 9 of the Plustek A360 user manual — Functions of the scanner
Page 9 · click to enlarge
Page 9
5. OPERATIONAL INFORMATION – Displays the scanner status.
LampStatus AnThe scanner is on, ready to scan images. ExciseThe scanner is off, either because it’s not switched on or because the power cable wasn’t plugged into the power supply outlet correctly.
6. Scanner buttons – You can press any key to perform a pre-configured scanning action.
7. TRAINING OF THE SKNESS (located at the bottom of the scanner) – This allows to lock the scanning head during transport.
8. ON/OFF Switch – Here the scanner is switched on and off.
Plustek A360 — Functions of the scanner diagram (page 9)
Fig. 5 · Functions of the scanner
9. NETWORK CONNECTION – Here the scanner is connected to a normal socket via the supplied power supply.
10. USB LINK – The scanner is connected to the computer’s USB port via the included USB cable.
Page 10 of the Plustek A360 user manual — Attention
Page 10 · click to enlarge
Page 10

K APITEL I. I INSTALLATION OF THE S CANNER

Before you start installing the scanner, you need to make sure that all necessary components are available. A list of components included in the package can be found under “Scope of Delivery” section.“ At the beginning of this manual.

INSTALLATION REQUIREMENTS

The scanner is equipped with the scanning software (Plustek DI Capture), task management software (plustek DocAction) and image processing program (NewSoft Presto! ImageFolio), the OCR program (I.R.I.S. Readiris Pro 10 Corporate Edition, the Document Management Program (NewSoft Presto!) PageManager), Adobe Reader and the scanner driver. For a full installation of these programs, you need about 400 MB space on the hard drive. To have enough space for software installation and document scanning and storage, there should be at least 1 GB of free space.

The USB scanner only works on Windows vista, XP or 2000 Professional.

Please do not use multiple USB scanners with Windows XP at the same time! For more information, please click the following URL... http://www.microsoft.com

Attention

H ARDWARE REQUIREMENTS

This scanner transmits data via USB (Universal Serial Bus), which Connecting when operating without restart (Hot Plug and Play) is possible. To determine your computer’s USB capability, check to see if there is a USB port on the back of the computer that matches the figure below. If you have trouble identifying your computer’s USB port, see the hardware documentation on the computer.

The computer should have one or two rectangular USB ports that usually look like this picture.

Page 11 of the Plustek A360 user manual — Step 1. Unlocking scanner
Page 11 · click to enlarge
Page 11
Plustek A360 — Installing and setting up scanners diagram (page 11)
Fig. 6 · Installing and setting up scanners
Plustek A360 — Installing and setting up scanners diagram (page 11)
Fig. 7 · Installing and setting up scanners

If your computer does not have such a USB port, you will need to purchase a certified USB interface card in order to upgrade the computer for USB.

S CANNER INSTALL AND SET UP

Follow these step-by-step instructions to install the USB scanner.

First, choose a suitable location! z Always place your scanner on a flat, smooth and stable surface before you start using the scanning device or any scanner application. Leaning or uneven surfaces could cause paper intake disturbance, scanner damage or bodily injury. (z) The scanner shall not be used in a highly dust-contaminated environment. Dust particles and other foreign bodies could damage the device.

Step 1. Unlocking scanner

This scanner is equipped with a locking mechanism in order to fix the scanner head during transport. Before connecting to the computer, you need to unlock the scanner.

To unlock the scanner, slide the shutter on the bottom of the scan toward the back of the scanning device until it snaps. Refer to the chapter “Locking of the scanner head” on page 24 of this guide for more information.

USB ports

Page 12 of the Plustek A360 user manual — Step 2. Connecting the scanner to your computer
Page 12 · click to enlarge
Page 12
Plustek A360 — Step 2. Connecting the scanner to your computer diagram (page 12)
Fig. 8 · Step 2. Connecting the scanner to your computer

Step 2. Connecting the scanner to your computer

Plustek A360 — Step 2. Connecting the scanner to your computer diagram (page 12)
Fig. 9 · Step 2. Connecting the scanner to your computer

Make sure the scanner is off before you remove the power supply.

1. Connect the power supply to the mains connection on the scanner.
2. Attach the power cable to the power supply.
3. Connect the other end of the power cable to a standard
Page 13 of the Plustek A360 user manual — Step 3. Installing software
Page 13 · click to enlarge
Page 13

AC socket.

4. Connect the rectangularly shaped plug of the supplied USB cable to the USB port of the scanner.
5. Connect the rectangular end of the USB cable to a free USB port on the back of your computer.
6. If you want to connect the scanner to a USB console 4, make sure that it is connected to your computer. Then connect the scanner to the USB console.

Step 3. Installing software

1. Turn on the scanner at the side.
2. If your computer’s USB components are working fine, the scanner will be automatically detected and the wizard started to add new hardware.

If the computer was turned off when you installed the scanner, after Windows next launches it will display a “Hardware Assistant” message.

3. In Windows 2000:

a. Click on it FurtherOnce the Hardware Assistant dialog box has been

appears.

b. Select the “Find for the Best Driver” option

(Recommended) and click on Further.

c. In the next dialog box, you will be asked to send your target drive to

Driver search. Select the option CD-ROM drive and deactivate the option Disk drive (if marked).

d. Place the CD-ROM supplied with the scanner to set up the

Scanners into the CD-ROM drive and click Further.

e. Click on the button in the following window Further.

f. During the installation process, a message "Digital Signature required" is displayed. Ignore them and click on Yesto proceed with the installation. The correct scanner function is nevertheless ensured. Then proceed to step 6.

4. On Windows XP:

a. Insert the supplied CD-ROM into the CD drive.

4 A USB console is not included.

Page 14 of the Plustek A360 user manual — Step 4. Testing scanners
Page 14 · click to enlarge
Page 14

b. Select Automatic Software Installation [Recommended] and click

on Further.

c. Click on the button in the following window Further. Drive

then proceed to step 6.

5. On Windows Vista:

a. Select the option “Automatically Install Software [RECOMMENDED]”

(Locate and install driver software) as soon as the dialog box of “Found New Hardware” appears.

b. Click on [Continue] when the “User Account Control” is activated.

The dialog window opens.

c. Insert the supplied CD-ROM into the CD drive if

The window will appear: “Insert the disc that came with your USB Scanner” and click [Next].

d. During the installation process, a message is sent: “Windows can

Publishers of this driver software do not check (Windows can’t verify the publisher of this driven software) displayed. Ignore them, and click [Install this driver software anyway] to proceed with the installation. The correct scanner function is nevertheless ensured.

6. After the installation is complete, click Finish to close the Hardware Assistant.
7. To install the required software for your new USB scanner, follow on-screen instructions.
8. After installing the software, close all open applications and click on the Finish button to restart your computer now.

If the scanner installation and corresponding screen messages should be omitted, click on StartSelect the option Executions and give them D: Install a (where D: must indicate the drive letter of the CD-ROM drive).

Step 4. Testing scanners

The following instructions show how to check that the scanner works correctly with your computer and scanning software by taking your first scan using our bundled image processing application, NewSoft Presto! ImageFolio. Before testing the scanner, you should check again that all cables are permanently connected.

Page 15 of the Plustek A360 user manual — I.E. INSTALLATION OF ADDITIONAL PRODUCTS
Page 15 · click to enlarge
Page 15

Test flatbed mode:

1. Open the document cover of the scanner. Place a document face down on the glass plate so that the top left corner of the document is against the arrow for marking.
Plustek A360 — Test flatbed mode: diagram (page 15)
Fig. 10 · Test flatbed mode:
2. Carefully close the scanner cover.
3. Under Start – Programs – Select the NewSoft Presto program! ImageFolio and start it.
4. (If only one scanner is connected to your computer, please skip point 5) If you have more than one scan or any other image processing device installed on your computer: Click Select Source from the File Menu of Presto! ImageFolio program and then select this scanner as your predefined scanning source.
5. Click on the Presto program! ImageFolio on File > Import > Import .
6. Select flatbed reflectively as the scan type in the open Twain window.
7. Click on the Scan button.
8. If an image is displayed on the screen, your scanner will work properly.

I.E. INSTALLATION OF ADDITIONAL PRODUCTS

Our scanners are TWAIN-compatible and therefore work together with virtually all TWAINE-compatible programs. If you purchase additional software for use with the scanner, make sure that it complies with TWAIN standard.

Page 16 of the Plustek A360 user manual — (K) APITEL II. S CANNEN
Page 16 · click to enlarge
Page 16

(K) APITEL II. S CANNEN

In principle, the scanner must be controlled via a software program. Since all scanned documents (whether text or graphics) are treated by the computer as image files, scanning is usually carried out via an image processing program with which the scan results can be viewed, post-edited, saved and printed. On the included CD-ROM with installation and application programs is an image editing program. They can use it to modify and correct scanned images by using filters and tools.

You want to scan text documents and process them further in your word processing? Then you need an automatic text recognition (OCR) program. OCR programs convert the graphics files created after scanning text documents into text files that can be viewed, edited and stored with word processors. An OCR program is also already on the CD-ROM included in your scanner. Install it if you want to use the scanner for scanning and processing text documents.

As the name suggests, DI Capture is a specialized document image recording and processing program that allows you to digitize your documents conveniently and automatically save their electronic files in an order. If you are not used to scanning, no problem : the Scan Wizard will guide you how to do each scanning task.

The DocAction program, which seamlessly integrates the handling of your scanner with that of computer and other devices, provides a quick and convenient way to perform various scanning functions. Thanks to DocAction, you don’t have to reset the settings every time you want to scan something. Just press any button on the front panel of your scanner or click any DocAction Scan menu icon on your screen. The scanner begins to scan your paper documents and transfer them to your assigned destination. The target can be a printer, your email program, files on your hard drives, an image editing program, etc. be.

Please contact the respective online help of each program to answer your questions, which may be available. occur during scanning.

This chapter describes three important steps of the scanner operations. Read the steps thoroughly and follow the instructions to ensure proper use and optimal scanner performance.

1. Preparing documents Step 2. Place documents step 3. Scanning documents
Page 17 of the Plustek A360 user manual — D OKUMENTE SCANNING
Page 17 · click to enlarge
Page 17

D PREPARING THE OKUMENTE

Adequate document preparation before scanning can prevent paper jams and damage to the scanner.

Review of document properties

Verification of document properties

Make sure that the paper formats of your documents can be processed by the scanner. Refer to “Appendix A: Technical Data” of this manual for more detailed information.

D PLACEMENT OF OKUMENTS

Use of the flat bed

1. Open the document cover of your scanner.
2. Place a document face down on the glass plate so that the top left corner of the document is against the arrow for marking.
3. Carefully close the scanner cover.

D OKUMENTE SCANNING

There are four different ways to use the scanner:

1. By scanning images with the help of our TWAIN interface, within any TWAINE-compliant application program.
2. By scanning images within our DI capture software.
Page 18 of the Plustek A360 user manual — Scanning within the NewSoft Presto! ImageFolio:
Page 18 · click to enlarge
Page 18
3. When scanning via the buttons on the scanner.
4. Scanning on the screen via DocAction.

The TWAIN interface, DI Capture software and DocAction software are automatically installed on your system along with the scanner driver.

Before you start scanning, check the following:

z Your scanner has already been unlocked and both your computer and scanner are on.

It appears on your Windows taskbar. z The paper is properly placed on the flat-bed scanner glass.

Scanning with the TWAIN user interface

The TWAIN driver is a very important program that comes with your scanner. This program controls communication between the scanner hardware and software used to view, edit, output or transfer your documents. The TWAIN driver allows you to control the scanning process and operate the scanner. Not only can you specify what type of template to scan, but also make a number of settings that affect the quality of your scanning result.

The following describes how you use our included image editing application (NewSoft Presto!) ImageFolio) and OCR software (I.R.I.S. Readiris Pro 10 Corporate Edition) can be used for scanning with TWAIN surface. Once you are familiar with scanning, you can also use other TWAIN-compatible scan tools or image processing applications for your scanning projects.

Scanning within the NewSoft Presto! ImageFolio:

1. Select Start Æ Program: Presto! ImageFolio and start this.

z The symbol

Page 19 of the Plustek A360 user manual — Scanning with I.R.I.S. Readiris Pro 10 Corporate Edition:
Page 19 · click to enlarge
Page 19

If more than one scanner or image processing device is connected to the computer, you must set this scanner as a standard scanner before TWAIN program capture occurs.

1. Click Select Source on the Presto File Menu! ImageFolio. 2. Select this scanner in the window that appears and click on the OK button to set this scan as the default can source.
2. Click on the Presto program! ImageFolio on File > Import > Import .
3. Please select flat bed reflectively as the scan type in the opening TWAIN window.
Plustek A360 — Scanning with I.R.I.S. Readiris Pro 10 Corporate Edition: diagram (page 19)
Fig. 11 · Scanning with I.R.I.S. Readiris Pro 10 Corporate Edi…
4. Adjust the scanner settings.
5. Click on the Preview button. The scanned image should now appear in the preview window. Using the mouse, you can set the exact dimensions of the cutout to be scanned or cut out areas that you do not want to scan. Adjust the scan settings again if the preview does not meet your requirements.
6. Click on the Scan button.
7. When the scan is finished, please click on the Finish button to close the TWAIN window. The scanned images are in the Presto! ImageFolio, and you can now start editing the image.
Page 20 of the Plustek A360 user manual — Scanning with Plustek DI Capture
Page 20 · click to enlarge
Page 20

Scanning with I.R.I.S. Readiris Pro 10 Corporate Edition:

1. Under Start Æ Programs: Iris Applications, select Readiris Pro 10 Corporate Edition.

If more than one scanner or image processing device is connected to the computer, you must set this scanner as a standard scanner before TWAIN program capture occurs.

1. Click in Readiris Pro 10 Corporate Edition

on the left. 2. Please click on the button Scanner type. Select in the type window Show Twain user interface Then click on the OK button. 3. In the next window that opens, please click on the button Configuration. 4. Select this scanner in the dialog window and click on the button Choosing, to set this scanner as your standard source of the scanner. 5. Click on it OK And you'll get back to the workspace of Readiris.

2. Within the Readiris Pro 10 Corporate Edition program, please click

on the left.

3. Select flatbed reflectively as the scan type in the open TWAINDialog window.

4. Adjust the scan settings. 5. Click on the button Preview. The scanned image should now appear in the preview window. Using the mouse, you can set the exact dimensions of the cutout to be scanned or cut out areas that you do not want to scan. Adjust the scan settings again if the preview image does not meet your requirements. 6. Click on the button Scanning. 7. The scanned images are displayed in the Readiris main window, and you can now proceed with OCR to convert the pictures into PDF or text formats.

Scanning with Plustek DI Capture

1. Click the Windows Start button Æ Programs to launch DI Capture.

the scanner button · on the scanning icon

Page 21 of the Plustek A360 user manual — Scanning with Plustek DI Capture
Page 21 · click to enlarge
Page 21
Plustek A360 — Scanning with Plustek DI Capture diagram (page 21)
Fig. 12 · Scanning with Plustek DI Capture
2. Within the DI Capture, select this scanner in the drop-down list

Off.

3. Select a document from the window folder around the scanned images

To save, click the button

on the toolbar.

4. Choose an appropriate scan profile. (You can click the Scan Settings Shield window to check if the current settings of your chosen scan profile meet your needs.) If not, you can click the Create or Edit button next to your scan profile to create a new profile or modify an existing one.
5. Click on the

button on the toolbar.

6. When the scan is complete, all of the images that have been scanned will be displayed in the browser window. The last scanned image appears in the View window (large window).

Click the button on the toolbar so that Scan Wizard accompanies you through the entire scanning process.

As an alternative, you can also

You can also tailor your own user interface of the DI Capture such as for example the toolbar buttons, window view, browser window, etc.

Show 9 more labels / short text on this page
Scan Profile · Toolbar · Select Scanners · Window View · Windows · Folders · Browsers · Windows Scan Settings · and/or
Page 22 of the Plustek A360 user manual — Scanning with the keys
Page 22 · click to enlarge
Page 22

Please refer to DI Capture’s online help to find out more about this feature!

Scanning via the control panel or program DocAction

The settings for each button on the scanner can be configured in DocAction. DocAction provides quick access to the most common scanning features. They are especially useful if you need to scan repeatedly with the same settings and send results to the same destination.

The buttons on the scanner are used in this guide to demonstrate the possibilities of the scan. You could also use DocAction’s Run screen menu to perform the same scanning tasks.

Configuration of button settings

Before you run your first scan via scanning buttons, it is recommended that you configure the key settings according to your requirements and preferences. There are two ways to view or configure DocAction key settings:

z Double-click the icon

in the Windows system bar.

z Click right on the icon

in the Windows system bar, and select Configuration of buttons in the pop-up menu.

Within the "Configuration of buttons" window, you can find a series of icons in the left section of the window. Each icon represents a button on the scanner control panel (as well as in DocActions’ Run screen menu). Click any button on the left section and its current key settings will immediately appear in the right section. Adjust the special functions that belong to the function key.

Click the Help button within the “Configuration of Buttons” window to get more information.

Scanning with the keys

Scanning documents or images with this scanner is very easy. Follow the two steps described below:

1. Place the document or image on the scanner. (Refer to “Chapter II”). Scanning" this guide for more information about the proper placement of paper on flatbed glass.
Page 23 of the Plustek A360 user manual — Scanning via the control panel or program DocAction
Page 23 · click to enlarge
Page 23

For OCR purposes, place text documents only. Do not scan a photo with the OCR button.

2. Run one of the following instructions to start the scan: z Press the button on the control panel of the scanner.

z Right-click on the symbol

in the Windows system bar, and select Executions in the pop-up menu that opens. Click the desired function key icons in the pop-up menu.

The scanner starts scanning immediately and performs the corresponding action according to the settings you have set in the "Configuration of buttons" window.

Page 24 of the Plustek A360 user manual — Cleaning the flat bed
Page 24 · click to enlarge
Page 24

K APITEL III. W SPECIES AND P FLEGE

Your scanner is designed to be maintenance-free. Nevertheless, regular maintenance and care can significantly extend the life of your scanner and ensure a smooth workflow.

S CANNER CLEANSING

Paper dust, dust ink and toner from the scanned paper can contaminate the scanning glass which may lead to poor image quality or paper jam.

Perform the following steps to clean the scanner surface and glass. Swipe the described parts gently. Don't rub too hard.

Before cleaning the scanner, turn off the scan and remove the power and USB cables, and wait a few minutes for the glass to cool down to room temperature. z Wash your hands with soap and water after cleaning your scanner.

Cleaning materials

Keep the following cleaning materials ready to clean the scanner:

a soft, dry lint-free cloth (or Q tip) A non-aggressive cleaner Isopropyl alcohol (95%) Do not use water.

Alternatively, you can use glass cleaners or a natural window cleaning agent to clean the scanner glass.

Using other cleaning materials could harm your scanner.

Cleaning the flat bed

1. Open the document cover.
2. Wipe over the following surfaces with the cleaning liquid moistened cloth.
Page 25 of the Plustek A360 user manual — The adjustment for the flatbed scan:
Page 25 · click to enlarge
Page 25

Cleaning of the document pad and scanning glass:

Plustek A360 — Cleaning of the document pad and scanning glass: diagram (page 25)
Fig. 13 · Cleaning of the document pad and scanning glass:
3. Wait until the cleaned surfaces are properly dried.
4. Carefully close the scanner cover.

S CANNERS ALIGN

In most cases, the scanner does not need to be aligned but it may happen that an orientation is necessary. An alignment of the scanner is only necessary if parts of the original are not scanned at the edges. For example, scanning does not skip the header of a document.

The adjustment for the flatbed scan:

1. Place a document face down on the glass plate so that the top left corner of the document is against the arrow for marking.
2. Click the icon

on the Windows taskbar.

3. Click Scanner Utility in the open menu.
4. The scanner utility window opens. Find the Scan Start PositionAlignment section and select Flat Bed reflectively as a source.

Document cushion · scanner glass

Page 26 of the Plustek A360 user manual — E ENERGY SAVING MODE
Page 26 · click to enlarge
Page 26
Plustek A360 — Energy saving mode diagram (page 26)
Fig. 14 · Energy saving mode
5. Click on the Scan button. Part of the document is displayed in the Adjust window field.
6. Click the Adjustment Keys (Up, Down, Left, Right) until the top left corner of the scanned document nestles against the upper left corner in the adjust window field.
7. Once the adjustment is ready, please click on the OK button to save and complete the settings.

E ENERGY SAVING MODE

You can decide whether you want to keep the scanner lamp always on or define an empty time for the lamp so that it automatically turns off.

1. Click on the icon

in your Windows taskbar.

2. Click Scanner Utility in the pop-up menu.
3. Please click on the button of your choice in the standby section of the opening Scanner Utility window:

Template for alignment · Adjusted keys Window Adjust

Page 27 of the Plustek A360 user manual — V LOCKING OF THE S CANNERKOPF
Page 27 · click to enlarge
Page 27

a. To keep the lamp always on: Click on this

Box before ‘lamp always on”.

b. To turn off the lamp automatically: Click on the box

before ‘Turn off lamp after scanner ... minutes unused” and then click on the up or down arrow to set a standard time for the lamp after which it should turn off.

4. Please click on the OK button to save and complete settings.

z To completely shut down the scanner, press the off button on the side of the scan. z If the scanner is not to be used for a long time, turn off the scan and then remove the power cord from the socket.

To turn the lamp back on, you can simply perform any scanning task.

V LOCKING OF THE S CANNERKOPF

The scanner is equipped with three different locking statuses to protect the optical parts. For the scanner to function properly, you need to choose the appropriate locking status depending on the situation.

Always unlocked: A scan-ready state. If you permanently install your scanner at one location, you can leave the scanner lock in this status. Rear

Page 28 of the Plustek A360 user manual — Always blocked:
Page 28 · click to enlarge
Page 28

Unlock the scanner, slide the shutter on the bottom of the scan toward the back of the scanning until it snaps.

Plustek A360 — Always blocked: diagram (page 28)
Fig. 15 · Always blocked:

Always blocked: This measure keeps the scanner head in place during a transport or journey. The scanner is kept in a state of disability. To secure the scanner, slide the shutter on the bottom of the scan toward the front of the scanning device.

Plustek A360 — Always blocked: diagram (page 28)
Fig. 16 · Always blocked:

If you want to reposition the scanner, please lock the scan in order to maintain accurate and problem-free use of your scanner.

Page 29 of the Plustek A360 user manual — V CONNECTION WITH THE S CANNER
Page 29 · click to enlarge
Page 29

(K) APITEL IV. S TROUBLESHOOTING

If a problem arises during the operation of your scanner, read again the instructions for installation or re-installation. for problem analysis in the relevant chapters of this manual.

Before contacting customer service, please read the information in this chapter and look up our FAQ (Frequently Asked Questions) where you can find useful information. The FAQs can be found under Windows STARTING Menu Æ Programmes > The folder of your scanner, and there please click FAQ.

V CONNECTION WITH THE S CANNER

If connection problems occur, check all of them first

cable connections. The symbol

in the Windows taskbar indicates whether the scanner software has been started correctly and that the computer and the scan communicate with each other.

The software was successfully launched. The scanner is connected to the computer and ready for use.

There is no connection between the computer and scanner. Or the power supply to the scanner was not switched on. No ads You have terminated the software – regardless of whether

Scanner is connected to the computer or not.

Display status

Page 30 of the Plustek A360 user manual — Plustek OpticPro A360
Page 30 · click to enlarge
Page 30

A NHANG A: TECHNISCHE D ATEN 5

Plustek OpticPro A360

Optical resolution600 dpi max. Hardware resolution: flatbed: 600 x 1200 dpi

Input format 48-bit color, output format 24 bit input format 16-bit grayscales, output style 8 bit black/white: 1 bit (dash drawings)

Scanning range (B x L)

Maximum 304.8 x 431.8 mm Minimum 12.7 x 12.11 mm

Supported paper format (B x L) Maximum 304.8 x 431.8 mm

Input voltage/frequency:

100Vac – 240Vac (-10 % to +10 %) 47 to 63 Hz output voltage/Watt:

Energy consumption Operation< 36 W standby mode: 8 watts

Interface USB 2.0 HighSpeed

Operating temperature from 5°C to 35°C

Relative humidity 20% to 80% (non-condensing)

Dimensions (BxTxH) 623 x 400 x 133 mm

EMV FCC Class A, CE

5 The hardware specifications can be changed at any time without prior notice.

Show 6 more labels / short text on this page
Scan modes · Cold cathode lamp type · Power supply · 24Vdc, 1.67A · Weight 7.7 Kgs · Protocols TWAIN compatible
Page 31 of the Plustek A360 user manual — E RESTRICTED G ARANTIE DECLARATION
Page 31 · click to enlarge
Page 31

A NHANG B: K UNDDIENST

If you need further help, go to our WWW homepage or contact one of our customer service representatives (see last page of this guide). Our employees are happy to be at your disposal from Monday to Friday during business hours.

To avoid delays, you should provide the following information before calling:

Product name and model numberSerial number of the scanner (located at the back of the device)Scanner CD version and single part numberDetailed description of problemManufacturer's name and designation of your computerSpeed of CPUThe operating system used and BIOS designation for the computer (optional)Designation of software packages with version numbers and manufacturer of softwareOther installed USB devices

E RESTRICTED G ARANTIE DECLARATION

This declaration applies exclusively to products that were originally purchased for their own use (not resale) by an authorized dealer.

For scanning or editing large amounts of image data, the requirements may be higher. The specified system requirements are only a guideline. In general, the better the computer (main circuit board, processor, hard drive, RAM, video card), the better results.

If the product is passed on to another user, he/she shall be entitled to guarantee services for the remainder of the warranty period. The proof of purchase and this declaration should be transferred to his possession upon transfer.

We guarantee that this program is in working condition and technically complies with the descriptions contained in the attached documentation. The remaining warranty period shall be transferred to the corresponding spare parts upon presentation of proof of purchase of original parts.

If you submit this product for warranty, you must first remove all programs, data and removable storage media. Products sent in without accessories will be replaced without accessory.

Page 32 of the Plustek A360 user manual — FCC-E CLARIFICATION
Page 32 · click to enlarge
Page 32

This limited warranty does not apply in the event that the problem is caused by an accident, a disaster, vandalism, abuse, improper use, unsuitable environment, modification through a program or another device or by other modifications not caused by the Seller.

If this product is an extension, the warranty applies only if it was used in a device for which it has been designed.

If you have any questions regarding this Limited Warranty Statement, contact the Authorized Dealer from whom you purchased the product or our telephone customer service whose phone number is listed on the last page of this guide.

THIS LIMITED WARRANTY STATEMENT SUPERSEDES ANY OTHER WARRANTIES OF AN EXPRESS OR IMPLICIT NATURE: THIS INCLUDES THE GUARANTEE OF SALEABILITY OR SUITABILITY FOR A PARTICULAR PURPOSE; HOWEVER, IT IS NOT LIMITED TO SUCH. IN SOME COUNTRIES, THE EXCLUSION OF IMPLICIT GUARANTEES IS NOT PERMITTED BY LAW. IN THIS CASE, THE VALIDITY OF ALL EXPRESS AND IMPLIED WARRANTIES IS LIMITED TO THE WARRANTY PERIOD. UPON EXPIRATION OF THIS PERIOD, ALL WARRANTIES SHALL CEASE TO BE VALID.

In some countries, a limitation of the validity period of implied guarantees is not legally permitted and therefore the above restriction does not enter into force.

We are not liable under any circumstances for:

1. Claims against you from third parties for loss or damage.
2. Loss or damage to your records or data.
3. Consequential economic damage (including lost profit or saving) or accompanying losses, even in the event that Plustek is informed of the possibility of such damage.

In some countries, the exclusion or limitation of accompanying damages or consequential harm is not legally permitted so that the above restriction does not enter into force.

You have specific rights due to this limited warranty statement. You may also have other rights that differ depending on the legislation applicable to you.

FCC-E CLARIFICATION

This is a Class A product. This device generates and uses radio frequency energy, which can radiate it.

Page 33 of the Plustek A360 user manual — FCC declaration
Page 33 · click to enlarge
Page 33

This device generates, uses and can emit radio frequency energy and - if not installed and used in accordance with the operating instructions - may cause interference of radio communication. However, there is no guarantee that it will not cause any malfunctions in certain installations. If this equipment causes radio or television reception interference, which can be easily detected by switching it off and on, the user is advised to eliminate the disturbance by one or more of the following measures:

Re-align the receiving antenna or place it in another location. Increase the distance between the device and the receiver. Connect the device and receiver to two different circuits. The shielded connection cable and the shielded power cord must be used with this device to ensure that legal regulations are complied with. Contact a specialist dealer or an experienced radio/television technician. In the event of changes that have not been expressly approved by the manufacturer or an authorized specialist dealer, the user loses his operating license. This device complies with Part 15 of the FCC regulations. Operation shall be subject to the following two conditions: (1) This equipment must not cause any malfunction. (2) This equipment shall be capable of absorbing all malfunctions, including those resulting in undesirable operation.

Page 34 of the Plustek A360 user manual — S O REACHING THE P LUSTEK
Page 34 · click to enlarge
Page 34

S O REACHING THE P LUSTEK

Europe: Plustek Technology GmbH Gutenbergring 38 22848 Norderstedt Germany Tel: +49 (0) 40 523 03 130 Fax: + 49 (0)40 52303 500 E-mail: [email protected] Internet hompage www.plustek.de North America: Plustek Technology Inc. 17517 Fabrica Way, Suite B Cerritos, CA 90703 U.S.A. Tel: +1 -714-670-7713 Fax: + 1 -715-670 - 7756 Email: supportusa@plustek.com Worldwide except Europe &

Plustek Inc. 13F-1, No.3 (Building F), Yuan Qu Street 115 Nankang, Taipei Taiwan Tel: +886-2-2655 7866 fax: + 886-2-3655 7833 Internet hompage: www.plustek.com

North America:

Visit our website http://www.plustek.com/support/support.htm

For further customer service information

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Plustek A360

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Plustek A360

Be the first to ask — other owners or our team will answer.

Original document

Plustek A360 manual PDF

34 pages·1.9 MB·Scanner·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…