Instruction/ maintenance manual of the product JSAYDL Pentair
Go to page of 16
DURA-JET TM PUMP O W N E R’ S M A N U A L INST ALLA TION, OPERA TION & P AR TS MODELS 1/2 HP 3/4 HP 3/4 HP 1 HP 1 HP 1-1/2 HP (2-Speed) (2-Speed) JSA CL JSADL JSA YDL JSAEL JSA YEL JSAFL JSADL-2.
2 DURA-JET SP A PUMP To avoid unneeded service calls, prevent possible injuries, and get the most out of your pump, READ THIS MANUAL CAREFULLY! The Sta-Rite ‘JS’ Series Tub Pump: • Is designed to circulate hot water in spas and hot tubs. • Is an excellent performer; durable, reliable.
3 READ AND FOLLO W ALL INSTR UCTIONS! This is the safety alert symbol. When you see this symbol on your sys- tem or in this manual, look for one of the following signal words and be alert to the potential for personal injury. warns about hazards that will cause death, serious personal in- jury, or major property damage if ignored.
4 INST ALLA TION Installation and wiring of pump should only be done by qualified, licensed personnel. Pump mount must: Be Solid - Level - Rigid - Vibration free. (To reduce vibration and pipe stress, bolt pump to mount.) Be installed with pump suction inlet below water level at all times (this al- lows pump to prime).
5 ELECTRICAL Ground motor before connecting to electrical power supply! Failure to ground pump motor can cause serious or fatal electrical shock hazard! Do not ground to a gas supply line! To avoid dangerous or fatal electrical shock, turn OFF power to motor before working on electrical connections.
6 V oltage: Voltage at motor must be not more than 10% above or below motor name- plate rated voltage or motor may overheat, causing overload tripping and re- duced component life. If voltage is less than 90% or more than 110% of rated voltage when motor is running at full load, consult power company.
7 OPERA TION Priming Pump: NEVER run pump dry! Running pump dry may damage seals, causing leakage and flooding! Fill pump with water before starting motor. Do not add chemicals to spa system directly in front of pump suction. Adding undiluted chemicals may damage pump and voids warranty.
8 Pump should only be serviced by qualified personnel. To avoid dangerous or fatal electrical shock hazard, disconnect power to motor before working on pump or motor! No lubrication or regular maintenance are needed. If shaft seal is damaged, repair as follows: Removing Old Seal: 1.
9 5. Screw impeller onto shaft until it seats against shaft shoulder. Work slinger over end of impeller sleeve so it rides on sleeve (Figure 6). 6. Remount front plate; using pattern, shown in Figure 7, torque bolts to 30 inch-lbs. (34.5 cm-kg). BE SURE to start with bolt in 3 o’clock position as shown.
10 Draining Pump: To avoid dangerous or fatal electrical shock hazard, turn OFF power to motor before draining pump. NOTICE: Do not use anti-freeze solutions (except propylene glycol) in your spa system. Most anti-freezes are hightly toxic and may damage plastic components in the system.
11 TR OUBLESHOO TING GUIDE Read and understand safety and operating instructions in this manual before doing any work on pump! A. PUMP DOES NO T OPERA TE 1. Check GFCI for proper operation according to GFCI manufacturer’s in- structions. 2. Check for plugged impeller.
12 1161 0695 1 5 8 9 7 3 4 6 2 11 11 12 1 2 13 7A • Not illustrated. * JSAFL-A, JSAEFL-A only. REP AIR P AR TS LIST DURA-JET TM SP A PUMP 3/4 through 1-1/2 HP Models Parts are common to all models listed except as noted; Key Nos. 1, Motor; and 8, Impeller, are listed below.
13.
14.
15.
S196 (Rev . A) 04-15-10 *S 196 *.
An important point after buying a device Pentair JSAYDL (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Pentair JSAYDL yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Pentair JSAYDL - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Pentair JSAYDL you will learn all the available features of the product, as well as information on its operation. The information that you get Pentair JSAYDL will certainly help you make a decision on the purchase.
If you already are a holder of Pentair JSAYDL, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Pentair JSAYDL.
However, one of the most important roles played by the user manual is to help in solving problems with Pentair JSAYDL. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Pentair JSAYDL along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center