23833A343 JET TANK SYSTEM with 7-gallon diaphragm pressure tank MODEL R-30-T7 1/3 Horse P ower Convertible Pump W A TER A CE PUMP COMP ANY • ASHLAND , OHIO 44805-1969 JET T ANK SYSTEM INST ALLA TION.
23833A343 IMPORTANT INSTRUCTIONS BEFORE INSTALLATION Failure to follow these instructions may cause serious bodily injury and/or property damage. 2 Warranty void if product modified, drilled, painted,.
23833A343 3 IMPORTANT SELECT CORRECT VOLTAGE USE COPPER CONDUCTORS ONLY VOLTAGE SELECTOR AT REAR OF MOTOR (USE NEEDLE NOSE PLIERS) PULL SELECTOR - ROTATE - REINSERT 115 230 115V 230V L2 L1 HIGH VOLTAG.
23833A343 4 STEP 1 Thread 1-1/4" male PVC adapter into foot valve. Hand tighten, then tighten 1/4 turn with crescent wrench. Subtract five feet from the depth of your well (See page 3 "Finding the Depth of Your Well").
23833A343 STEP 4 Remove pipe clamp and slide Well Seal #RWS4-12 over PVC pipe and onto well casing. Position assembly so twelve inches of PVC pipe pro- trude from well seal. Alternately turn bolts on well seal counterclockwise until rubber gaskets are tight against well casing and PVC pipe.
23833A343 DEEP WELL PUMP INSTALLATION (4" DIAMETER CASED WELL) For wells over 25, but not exceeding 60 feet in depth, the twin ejector must be installed down inside the well rather than attached to the front of the pump. Materials with part numbers are quality Water Ace parts.
23833A343 7 STEP 8 Thread 1-1/4" male PVC adapter into top hole in front of tank-mounted pump. Thread 1" x 4" nipple into bottom hole in front of pump. 1-1/4" PVC ELBOW 1" PVC ELBOW STEP 7 Cut 1" pipe 2" shorter than the 1-1/4" pipe.
23833A343 PROBLEM POSSIBLE CAUSES Pump will not prime • Not enough water. Stop motor, remove pressure gauge plug, and fill case with water. • Pump wired incorrectly. • Plugged venturi tube or nozzle. • Foot valve is sitting in sand or mud, or is stuck shut, or leaks.
REPLACEMENT PARTS 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 REF. NO. REF. NO. 24859C500 19101A019 14740A001 15760A510 19277A001 19100A029 19109A012 23188A002 25579A108 08728A00.
23833A343 REVISION TO PARTS LIST If a 3/4" x 3/4" regulator is used, f ollow the replacement par ts list f ound in the jet tank system installation manual. If a 1" x 1" regulator is used, the follo wing par ts will be different than the parts list found in the jet tank system installation manual.
An important point after buying a device Ace Hardware R-30-T7 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Ace Hardware R-30-T7 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Ace Hardware R-30-T7 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Ace Hardware R-30-T7 you will learn all the available features of the product, as well as information on its operation. The information that you get Ace Hardware R-30-T7 will certainly help you make a decision on the purchase.
If you already are a holder of Ace Hardware R-30-T7, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Ace Hardware R-30-T7.
However, one of the most important roles played by the user manual is to help in solving problems with Ace Hardware R-30-T7. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Ace Hardware R-30-T7 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center