User Manual

This is a Class A device and is not intended for use in a residential environment.

Patton Electronics Company, Inc.
7622 Rickenbacker Drive Gaithersburg, MD 20879 USA
Trademark Statement The term SmartNode is a trademark of Patton Electronics Company. All other trade- marks presented in this document are the property of their respective owners.
Copyright © 2012, Patton Electronics Company. All rights reserved. The information in this document is subject to change without notice. Patton Elec- tronics assumes no liability for errors that may appear in this document.
Warranty Information The software described in this document is furnished under a license and may be used or copied only in accordance with the terms of such license.
Patton Electronics warrants all SN10200 components to be free from defects, and will—at our option—repair or replace the product should it fail within one year from the first date of the shipment.
This warranty is limited to defects in workmanship or materials, and does not cover customer damage, abuse or unauthorized modification. If the product fails to perform as warranted, your sole recourse shall be repair or replacement as described above. Under no condition shall Patton Electronics be liable for any damages incurred by the use of this product. These damages include, but are not limited to, the following: lost profits, lost savings and incidental or consequential damages arising from the use of or inability to use this product. Patton Electronics specifically disclaims all other warran- ties, expressed or implied, and the installation or use of this product shall be deemed an acceptance of these terms by the user.

1 General Information 13
2 Hardware Installation 16
3 Initial Setup and Web Management 29
4 Contacting Patton 49
A Compliance information 52
B Specifications 54


1 Mounting the SN10200 to a rack 18 2 Connecting the management interface 19 3 Computer to SN10200 Serial Port Connection 20 4 Console pinout 20 5 Connecting to a VoIP network 21 6 SCSI interface to the PSTN 23 7 DS3 interface to the PSTN 24 8 Optical interface to the PSTN 25 9 AC Power Connection 26 10 DC Power Connection 27 11 SN10200 Ethernet Management Interface 33 12 SN10200 Web Portal Navigation 35 13 SN10200 Web Portal Menus 35 14 SN10200 User Access Levels 36 15 Global > Users 36 16 User List 37 17 User List > Create New User 37 18 User List > Delete User 38 19 Navigation Menu: Logout 38 20 Global > Backups 39 21 Backups > Create new database backup 39 22 Database Backup Message 39 23 Database Backup List 39 24 Download Database Backup 40 25 Upload Database Backup File 40 26 Restore Database Backup File 40 27 Applications > Instances 41 28 Application Instance List 41 29 Application Instance List > Edit 42 30 Application Status 42 31 Apply States 42 32 SN10200 Interfaces 43 33 Application Status List 43 34 Global > Systems 44 35 System List 44 36 Name and Activate Configuration 44 37 Successful Activation 45 38 Global > Status 45 39 Status: General View 46 40 Status: Detailed View 46 41 Menu > IP Interfaces 47 42 IP Interface List 47 43 Editing an IP Interface 48

1 General conventions 12 2 SmartNode 10200 PSTN Ports and Voice Channels 15 3 SmartNode 10200 Height Requirements 18 4 Optical Interfaces 25 5 DC Power Cables 27 6 Configuration Parameters for IP Interfaces 48

This guide describes the SmartNode 10200 hardware, installation and basic configuration. For detailed soft- ware configuration information refer to the Smart Media Software Configuration Guide located online at http:/ /www.patton.com/manuals/Smart Media-scg.pdf.
This guide is intended for the following users:
This guide contains the following chapters and appendices:
For best results, read the contents of this guide before you install the SN10200.

SmartNode 10200 Series User Manual About this guide
The alert symbol and IMPORTANT heading calls attention to important information.
The alert symbol and CAUTION heading indicate a potential haz- ard. Strictly follow the instructions to avoid property damage.
The shock hazard symbol and CAUTION heading indicate a potential electric shock hazard. Strictly follow the instructions to avoid property damage caused by electric shock.
The alert symbol and WARNING heading indicate a potential safety hazard. Strictly follow the warning instructions to avoid personal injury.
The shock hazard symbol and WARNING heading indicate a potential electric shock hazard. Strictly follow the warning instructions to avoid injury caused by electric shock.

SmartNode 10200 Series User Manual About this guide
In accordance with the requirements of council directive 2002/ 96/EC on Waste of Electrical and Electronic Equipment (WEEE), ensure that at end-of-life you separate this product from other waste and scrap and deliver to the WEEE collection system in your country for recycling.
This device is NOT intended nor approved for connection to the PSTN. It is intended only for connection to customer premise equipment.

SmartNode 10200 Series User Manual About this guide
Always follow ESD prevention procedures when removing and replacing cards.
Wear an ESD-preventive wrist strap, ensuring that it makes good skin contact. Connect the clip to an unpainted surface of the chassis frame to safely channel unwanted ESD voltages to ground.
To properly guard against ESD damage and shocks, the wrist strap and cord must operate effectively. If no wrist strap is avail- able, ground yourself by touching the metal part of the chassis.
This section describes the typographical conventions and terms used in this guide.
General conventions The procedures described in this manual use the following text conventions:
Table 1. General conventions


SmartNode 10200 Series User Manual 1 • General Information
Service providers are adding VoIP capabilities to their networks, whether to reduce costs when inter- connecting with other carriers, to cost-effectively build out their net- work footprints, or simply to trans- port voice traffic across their IP backbones. This can be best accom- plished using a 16 to 64 E1/T1 SmartNode 10200 Series media gateway, which enables the delivery of VoIP services by bridging voice traffic between the public switched telephone network (PSTN)—based on time-division multiplexing (TDM)—and IP networks such as the Internet. Whether sitting at the network core or at the edge, SmartNode media gate- ways enable service providers to introduce VoIP into their networks while maintaining the quality and the reli- ability of traditional TDM networks.

Features • TDM Interfaces Service providers, whether providing local, long-distance or international voice services, are interconnected with a multitude of other providers using T1/E1, DS3 or STM-1 links. It is critical for service providers to be able to rapidly establish new interconnections without having to always deploy new devices. SmartNode 10200 Series media gateways therefore offer flexibility and can be configured to support T1/E1, DS-3 or STM-1 interfaces.
In parallel with the TDM and IP signaling protocols mentioned above, SN10200 devices also support the H.248 media gateway control protocol, which enables any H.248-compliant 3-party softswitch to control a media gateway. While the softswitch manages call control interactions, the SN10200 handles transmission of call media as well as any required transcoding.
SmartNode 10200 gateways feature extensive support for various wireline, mobile and IP telephony audio formats, delivering seamless transcoding in real-time. The media gateways ship with support for G.711, G723.1, G.726, and G.729ab right out of the box, with no additional license fee required. They also offer optional support for mobile and IP vocoders such as AMR, AMR-WB (G.722.2), GSM-FR/GSM-EFR,
SN10200 overview 14

SmartNode 10200 Series User Manual 1 • General Information
EVRC/QCELP, G.728, G.729eg, and iLBC. SN10200 gateways offer independent dynamic codec selec- tion per channel. This means that it is possible to assign different vocoders to different channels, on a chan- nel-by-channel basis. The devices can then run all of these codecs concurrently and do so with no impact on system performance.
SN10200 gateways also provide unparalleled support for Internet-based fax, also known as Fax over IP or Fax relay, using the T.38 protocol, which is used to carry fax communications over an IP network. (They also support the T.30 protocol for fax over the PSTN.)
SN10200 model codes The SmartNode 10200 series consists of several models. They differ in the type and number of PSTN inter- faces and voice channels supported. All models come equipped with one serial console management port, one Ethernet management port, two 100/1000/Base-T VoIP ports and two 100/1000/Base-T Ethernet ports.
The SN10200 models are listed in table 2.
Table 2. SmartNode 10200 PSTN Ports and Voice Channels
SN10200/16E/UI 16 - - 512
SN10200/32E/UI 32 - - 1024
SN10200/48E/UI 48 - - 1536
SN10200/64E/UI 64 - - 2048
SN10200/1DS3/UI - 1 - 672
SN10200/2DS3/UI - 2 - 1344
SN10200/3DS3/UI - 3 - 2016
SN10200/STM1/UI - - 1 2016


SmartNode 10200 Series User Manual 2 • Hardware Installation
Supplies In the SN10200 box, you will find:
Not included with the SN10200:
Procedures To install the SmartNode 10200, follow these steps:
Planning the installation 17

SmartNode 10200 Series User Manual 2 • Hardware Installation
The SN10200 is mounted on a customer provided equipment rack using the mounting hardware packaged in the box. To rack mount the SN10200, you will need:
The SN10200 is housed in a 2U chassis, as described in table 3. It is important that you provide for enough room on the equipment rack to allow for the installation of the SN10200. Consider the available space on your equipment rack and the height of the SN10200. Due to the rear-exhaust, heat vents and the efficient heat dis- sipation design, there is no need to leave any physical vertical space above or below the placement of the SN10200 on the equipment rack.
Table 3. SmartNode 10200 Height Requirements

a. SN10200 models configured with a 32 to 64 T1/E1 TDM mod-
ule require one patch panel for each 32 E1/T1 line grouping.
The SN10200 is mounted on the 19” equipment rack using the angle brackets and screws provided in the box. To mount the SN10200, follow these steps:

Figure 1. Mounting the SN10200 to a rack
Mounting the SN10200 to a rack 18

SmartNode 10200 Series User Manual 2 • Hardware Installation
The SmartNode 10200 Management Interface enables administrators to perform management tasks on the SN10200. To communicate with the Smart Media Management Interface for a SN10200, you will need a CAT5 Ethernet cable with RJ45 male-male terminations.
The SN10200 provides a Management Interface, using one Gigabit Ethernet network link, as shown in Figure 2. To communicate with the Management Interface:
TDM+VoIP Smart Media Gateway
Figure 2. Connecting the management interface
Connecting the management interface 19

SmartNode 10200 Series User Manual 2 • Hardware Installation
The serial port interface enables administrators to perform management tasks on the SN10200. To connect to the serial port of a SN10200:

Serial Terminal (PC) Note A Patton Model 16F-561 RJ45 to DB-9 adapter is included with
Figure 4. Console pinout
Baud rate Data rate Parity Stop bits Flow control
9600 8 bits None 1 None
Connecting to the console serial port 20

SmartNode 10200 Series User Manual 2 • Hardware Installation
The SN10200 features dual GigE ports for connection to different VoIP networks. This provides an access point to manage VoIP traffic. Should one of the IP networks fail, the SN10200 will continue to manage VoIP traffic using the alternate network.
To connect the SN10200 to the VoIP network, you will need:
The SN10200 is connected to the VoIP network by one or optionally two Ethernet GigE network links, as shown in Figure 5. To connect the SN10200 to the VoIP network:
0/0 0/1 0/0 0/1 0/0 0/1 49-64
Figure 5. Connecting to a VoIP network
Connecting to a VoIP network 21

SmartNode 10200 Series User Manual 2 • Hardware Installation
The SN10200 features a variety of interfaces to the PSTN network. To connect the SN10200 to the PSTN network, you must comply with one of the following:
Connecting to the PSTN 22

SmartNode 10200 Series User Manual 2 • Hardware Installation
SCSI Interface (T1/E1) A SN10200-xxE with 4 SCSI connectors enables the connection to T1/E1 lines. The termination impedance is set at 120 ohms. It is possible to connect an external balun in order to convert to 75 ohms (Figure 6).
To connect the SN10200 (SCSI) to the PSTN:
0/0 0/1 0/0 0/1 0/0 0/1
SCSI Patch Panel 1 (Rear)
SCSI Patch Panel 2 (Rear)
Figure 6. SCSI interface to the PSTN
Connecting to the PSTN 23
ETH VoIP SMP

SmartNode 10200 Series User Manual 2 • Hardware Installation
Dual BNC Interface (DS3) A SN10200-DS3 with 3 sets of BNC connectors enables the connection to DS3 lines (Figure 7).
To connect the SN10200-DS3 to the PSTN:
0/0 0/1 0/0 0/1 0/0 0/1
Rx Tx Rx Tx
DS3 Dual BNC connectors
Figure 7. DS3 interface to the PSTN
Connecting to the PSTN 24
Rx Tx BIT1 · ETH VoIP SMP

SmartNode 10200 Series User Manual 2 • Hardware Installation
Optical Interface (OC3/STM-1) A SN10200-STM-1, with one main and one backup OC3 or STM1 port enables connection to OC3/STM1 lines (Figure 8). Refer to table 4 for a listing of optical interfaces. The default SFP module for OC3/STM1 connection is SMF, intermediate reach, (SFP-OC3-IR1) 1310 nm with LC type connectors.
Automatic Protection Switching: The APS port is used for OC3/STM1 redundancy. Switchover occurs automatically based on configurable parameters. It is recommended that APS be used if the installation pro- vides this feature.
To connect the SN10200-STM1 (Optical Interface) to the PSTN:
0/0 0/1 0/0 0/1 0/0 0/1
APS MAIN
Figure 8. Optical interface to the PSTN
Table 4. Optical Interfaces
Model Description Spec Mode Type Range
SFP-OC3-IR1 OC3/STM1 Hot Pluggable Single-mode Intermediate reach
Hot Pluggable 75 ohms Copper
Max 180m Variable range N/A DIN (mini-coax)
Connecting to the PSTN 25

SmartNode 10200 Series User Manual 2 • Hardware Installation
The SN10200 is furnished with two AC or DC power connections. Only once all other equipment installation work has been completed should the SN10200 be powered up.
To power the SN10200, you will need:
Refer to the following sections for information about power:
Connecting to AC Power The SN10200 AC model is furnished with two AC power connectors. To connect the SN10200 to AC Power:
0/0 0/1 0/0 0/1 0/0 0/1
Figure 9. AC Power Connection

SmartNode 10200 Series User Manual 2 • Hardware Installation
Connecting to DC Power The SN10200 DC models are furnished with two DC power connection ports. In addition, each DC powered SN10200 is supplied with two DC power cables.
To connect the SN10200 to DC power:
0/0 0/1 0/0 0/1 0/0 0/1 49-64
Figure 10. DC Power Connection
Table 5. DC Power Cables

SmartNode 10200 Series User Manual 2 • Hardware Installation
Powering Down Powering down the SN10200 requires that the Linux embedded host be shut down. In order to do this, you must connect to the management interface using SSH, and enter:
DO NOT TURN OFF the power to the SN10200 using the power switch located at the rear, unless the Linux host has been properly shut down beforehand, using the reset button display, or manually using the shutdown command.
Allow enough time for the Linux host to shut down before turning the power to the SN10200 off (e.g. 1 min). Be aware that the shutdown procedure of the unit is logged and traceable for sup- port and warranty purposes.
shutdown -hp now · Connecting power 28


This chapter explains how to connect the SmartNode 10200 to the network, and how to access and manage the SmartNode Web Interface. Refer to the following sections for more details on:
You may access the SmartNode through the console management port, or through the Ethernet management port. Refer to the following sections for more information:
Logging into the SmartNode Console 1. To physically connect the console serial port, follow the instructions in “Connecting to the console serial port” on page 20.
Baud rate Data rate Parity Stop bits Flow control
9600 8 bits None 1 None
IP Address Network Mask
Ethernet Management (ETH 0/0) DHCP 255.255.255.0
DHCP address range 192.168.1.10–192.168.1.19 255.255.255.0
Overview 30

Changing the IP address 1. After logging into the console port, enter the following command to view the eth0 configuration:
IPADDR=192.168.1.10
NETMASK=255.255.255.0
IPV6ADDR=
IPV6PREFIX=
HOSTNAME=TB005376
GATEWAY=192.168.1.1
vi /etc/resolv.conf
Example (DNS configuration file without DNS server):
; generated by /sbin/dhclient-script
Example (DNS configuration file containing a DNS server):
; generated by /sbin/dhclient-script
nameserver 4.2.2.2
/etc/init.d/network restart
Accessing the SN10200 31

Setting the IP address to DHCP 1. To change the IP address from static to DHCP, enter the following command to modify the eth0 config- uration:
IPV6ADDR=
IPV6PREFIX=
DHCP_HOSTNAME=TB005376
HOSTNAME=TB005376
vi /etc/resolv.conf
Example (DNS configuration file without DNS server):
; generated by /sbin/dhclient-script
Example (DNS configuration file containing a DNS server):
; generated by /sbin/dhclient-script
nameserver 4.2.2.2
Accessing the SN10200 32

Accessing the SmartNode via the Ethernet Management port The SN10200 is shipped with the SN-CTRL pre-installed. In order to make changes to the system configura- tion, you must connect to the Management port labeled Ethernet on the front of the SN10200 to a terminal.
To access the SN10200, you must use an SSH connection. The password is set at the factory and is indicated on the shipment sheet.
TDM+VoIP Smart Media Gateway
Figure 11. SN10200 Ethernet Management Interface
Accessing the SN10200 33
![Page 34 of the Patton electronic 10200 user manual — – http://[DEVICE HOST NAME]:12358](/cdn/reader/63/63a0871c0dd3e749589ec2447cb81010cdaf4d0f57eaa95cc2b3528070d8652c/images/page-34.webp?w=400)
This section describes how to login and navigate the SmartNode 10200 Web Portal.
Connecting to the web server and logging on to the Web Portal The first step involved in initially configuring any Smart Media system involves logging on to the Web Portal. This can be divided into two distinct tasks: Connecting to the web server, and logging on to the Web Portal.
Connecting to the web server Using a web browser, connect to the Web Portal by typing the following in your address bar:
– http://[DEVICE IP ADDRESS]:12358
Logging on to the Web Portal In order to log on to the Web Portal configuration tool, enter the root user ID and password. The default values for these parameters are:
Navigating the Web Portal Effective use of the Web Portal requires a basic understanding of the physical elements of the tool, how to access its various components and knowing your current location in the Web Portal display. The following topics are covered: Navigation and Information Panels and Knowing Your Location.
Navigation and Information Panels The Web Portal has been designed with a consistent streamlined approach for the presentation of Smart Media configuration data. Information related to the hierarchy of data is displayed in the left-hand navigation panel, while information related to a selected category is displayed in the information panel found on the right side of the window.
Selecting a category in the navigation panel causes related configuration and status information to be dynami- cally displayed. The navigation panel displays information in a tree-like structure enabling you to understand how configuration parameters are contained by others.
Accessing and Navigating the Web Interface 34
or, alternately,


Figure 12. SN10200 Web Portal Navigation
Knowing Your Location As you navigate the Web Portal, it is important that you understand how to determine your current location. The Web Portal has been designed to make this easy for you. When you browse through the navigation panel, your current selection is always indicated by a graphical highlight. In addition, the system configuration that you are using and the specific Smart Media unit that is being configured is always displayed, as shown in the figure below.

Figure 13. SN10200 Web Portal Menus
Accessing and Navigating the Web Interface 35

This section describes how to mange user access levels in the SN10200 Web Portal. (Refer to “Connecting to the web server and logging on to the Web Portal” on page 34 for information about how to login to the Web Portal).
Understanding User Access Levels The Web Portal is designed to provide varying degrees of write and read privileges to users. By default, the root user is given full read and write access. This is required so that the root user can function as the system admin- istrator without any restrictions imposed. Subsequent users can be created with the ability to read and write, or just to read. An integer value from 0 - 9 is assigned to each user.

Figure 14. SN10200 User Access Levels
Viewing the User List It is possible to create an unlimited list of users, each with an assignment from 0-9. Any user can view the entire list of users, however only a root user with an access level of 0 can modify the access rights of other users.
To view the user list:

Figure 15. Global > Users
Managing Users 36


Figure 16. User List
Creating a New User 1. Select Users from the navigation panel.

Figure 17. User List > Create New User
Managing Users 37

Deleting a User 1. Select Users from the navigation panel.

Figure 18. User List > Delete User
Logging Off When you are finished working in the Web Portal, it is recommended that you log out from your session. If you do not log out, the session between the Web Browser on your PC and the Web Portal remains active.
To log out from the Web Portal, select Logout from the navigation panel.

Managing Users 38

After carrying out system modifications, it is recommended that you back up the SQL database. This section describes how to back up the database for the first time, retrieve a saved backup file, upload a new backup file, and restore the database from a backup file.
Carrying out a First Database Backup To create a backup file of the database:

Figure 20. Global > Backups

Figure 21. Backups > Create new database backup
Figure 22. Database Backup Message

Figure 23. Database Backup List
Managing the Database Backup 39

Downloading a Database Backup Once you have created a backup of your database, it is recommended that you download it to store it to an external storage device.

Figure 24. Download Database Backup
Uploading a Database Backup An external backup of your database can be uploaded to your SmartNode 10200.

Figure 25. Upload Database Backup File
Restoring a Database Backup The configuration settings of your system can be restored from a local or remote copy of your database.

Figure 26. Restore Database Backup File
Managing the Database Backup 40

This section explains how to manage applications and instances on the SN10200 Web Portal, how to activate a configuration, and how to configure IP interfaces. Refer to the following sections for information on:
Managing Applications This section explains how to start up and verify applications and instances on the Smart Media application server.
Viewing the List of Installed Applications The Smart Media application server is designed to run a large variety of applications. Before you can run an application, you must first be able to view it from a list of applications. To view the selection of applications:

Figure 27. Applications > Instances

Figure 28. Application Instance List
Applications are displayed in one of three states:
– Run (application is operating)
– Management (application is installed but not in operation)
– Fault (application has an operation fault)
Working with Configurations 41

Starting an Application In order to be able to load and start an application, it will need to have been installed on the Smart Media application server. In addition, at least one Smart Media unit must have been configured on the Smart Media application server so that you are able to connect to it.
When you first log on to the Web Portal, your system application will have been installed on the Smart Media application server, and it will be in a management state. This means that the application is not yet operating and controlling your system. In order to start an application, its state must be changed from Management to Run. To start an application:

Figure 29. Application Instance List > Edit

Figure 30. Application Status

Figure 31. Apply States
Working with Configurations 42

Verifying that an Application is Operating When an application’s target state is set to run, there are a number of crucial verifications that you should con- duct in order to know that an application is running properly. These verifications are as follows:

Figure 32. SN10200 Interfaces
Verifying the Application Path One important indication of the normal operation of an application is when the application path is displayed in the hardware status window. To verify that the application path is displayed:

Figure 33. Application Status List
Working with Configurations 43

Activating the Configuration Changes made to the configuration of the Smart Media units are stored on the OAM&P Configuration and Logging database. In order for changes to be used by the system, they must first be activated. This is done at the system level and accessed from the Navigation panel.

Figure 34. Global > Systems

Figure 35. System List

Figure 36. Name and Activate Configuration
Working with Configurations 44

Figure 37. Successful Activation
Verifying status General and detailed status information about the applications that are run by one or more host machine(s) is accessible from the Applications tab of the Global-->Status menu.

Figure 38. Global > Status
You may view the status in General View or Detailed View.
Working with Configurations 45

General View: The general view, shown below, lists the applications, and their current general status (ready, fault, not running. This window also provides a count of all applications with ready or fault status.

Detailed View: A more detailed description of each application can be viewed by following the appropriate link in the general window (shown above). The detailed status screen, shown below, lists the states of the appli- cation, its name, the host machine and the location of the application on the host.
From this detailed view, the Oam target state may be changed.
To modify the Oam target state of an application: Select a state from the Oam target state combo box. Click Apply States to change the states.

Working with Configurations 46

Configuring IP Interfaces The IP interface of the VoIP0 and VoIP1 ports can be configured by setting the following:
To configure a VoIP0 or VoIP1 port:

Figure 41. Menu > IP Interfaces

Figure 42. IP Interface List
– Indicate whether or not to use DHCP on this port
– Enter an IP address
– Enter a Netmask
– Enter a gateway address
Working with Configurations 47
– Click Save


Figure 43. Editing an IP Interface
The system will display the following notice, describing steps to apply your new configuration:
Table 6. Configuration Parameters for IP Interfaces
Use DHCP Indicates that the DHCP autoconfiguration protocol is to be used on an IP port.
IP Address Sets an address for accessing a new media gateway controller (MGC).
Netmask Sets a subnetwork mask number on an IP port.
Gateway Associates the address of a TCP/IP network gateway with an IP port.
Working with Configurations 48
List of Parameters · Parameter Description


SmartNode 10200 Series User Manual 4 • Contacting Patton
This chapter contains the following information:
Patton Electronics offers a wide array of free technical services. If you have questions about any of our other products we recommend you begin your search for answers by using our technical knowledge base. Here, we have gathered together many of the more commonly asked questions and compiled them into a searchable database to help you quickly solve your problems.
Patton support headquarters in the USA • Online support: available at www.patton.com
Alternate Patton support for Europe, Middle East, and Africa (EMEA) • Online support: available at www.patton.com
Patton Electronics is an ISO-9001 certified manufacturer and our products are carefully tested before ship- ment. All of our products are backed by a comprehensive warranty program.
Warranty coverage Our products are under warranty to be free from defects, and we will, at our option, repair or replace the prod- uct should it fail within one year from the first date of shipment. Our warranty is limited to defects in work- manship or materials, and does not cover customer damage, lightning or power surge damage, abuse, or unauthorized modification.
Introduction 50

SmartNode 10200 Series User Manual 4 • Contacting Patton
Out-of-warranty service Patton services what we sell, no matter how you acquired it, including malfunctioning products that are no longer under warranty. Our products have a flat fee for repairs. Units damaged by lightning or other catastro- phes may require replacement.
Returns for credit Customer satisfaction is important to us, therefore any product may be returned with authorization within 30 days from the shipment date for a full credit of the purchase price. If you have ordered the wrong equipment or you are dissatisfied in any way, please contact us to request an RMA number to accept your return. Patton is not responsible for equipment returned without a Return Authorization.
Return for credit policy • Less than 30 days: No Charge. Your credit will be issued upon receipt and inspection of the equipment.
RMA numbers RMA numbers are required for all product returns. You can obtain an RMA by doing one of the following:
All returned units must have the RMA number clearly visible on the outside of the shipping container. Please use the original packing material that the device came in or pack the unit securely to avoid damage during shipping.
Shipping instructions The RMA number should be clearly visible on the address label. Our shipping address is as follows:
Patton will ship the equipment back to you in the same manner you ship it to us. Patton will pay the return shipping costs.
Warranty Service and Returned Merchandise Authorizations (RMAs) 51


SmartNode 10200 Series User Manual A • Compliance information
EMC • FCC Part 15, Class A
This device generates and uses radio frequency energy, and if not installed and used properly-that is, in strict accordance with the manufacturer’s instructions-may cause interference to radio and television reception. The device has been tested and found to comply with the limits for a Class A computing device in accordance with specifications in Subpart B of Part 15 of FCC rules, which are designed to provide reasonable protection from such interference in a commercial installation. However, there is no guarantee that interference will not occur in a particular installation. If the device does cause interference to radio or television reception, which can be determined by disconnecting the unit, the user is encouraged to try to correct the interference by one or more of the following measures: moving the computing equipment away from the receiver, re-orienting the receiving antenna and/or plugging the receiving equipment into a different AC outlet (such that the computing equip- ment and receiver are on different branches).
Patton Electronics, Inc declares that this device is in compliance with the essential requirements and other rel- evant provisions of Directive 1999/5/EC. The Declaration of Conformity may be obtained from Patton Elec- tronics, Inc at www.patton.com/certifications
The safety advice in the documentation accompanying this device shall be obeyed. The conformity to the above directive is indicated by CE mark on the device.
D R M Green
European Compliance Services Limited.
Avalon House, Marcham Road
Oxon OX14 1UD, UK
Abingdon, · Compliance 53


SmartNode 10200 Series User Manual B • Specifications
VoIP channels—512 to 2,016
VoIP interfaces—Dual 100/1000Base-T • RJ45 connectors on rear of unit
Vocoding—Universal codecs: G.711, G.723.1, G.726, G.729ab, T.38 • Other codecs: G.722.2 (AMR-WB), G.728, G.729eg, iLBC, clear mode (RFC 4040)
Management interfaces—Dual 100/1000Base-T for OAM&P
SIP—Supported RFCs: 2327, 2976, 3261, 3262, 3263, 3264, 3311*, 3323*, 3325*, 3398, 3515*, 3578*, 3764, 3891, 4028 (*partial compliance)
SIGTRAN—M2PA, M2UA, M3UA, IUA • SS7 termination and/or relay supported
ISDN PRI—Q.931 ISDN PRI: NI-2, 4ESS, 5ESS, DMS-100, DMS-250, Euro ISDN ETSI NET5 (France, Germany, UK, China, Hong Kong, Korea), NTT (Japan), Australia
CAS—MFC R2 (standard ITU, Brazil) • Customizable protocol script files
Capacity and voice processing 55

SmartNode 10200 Series User Manual B • Specifications
Provisioning—Web-based interface for configuration • Dynamic activation
Operating temperature—32–131°F (0–55°C)
Operating humidity—95% (non condensing)
Dimensions—2U, 3.5H x 17.4W x 16D in. (88.9H x 442W x 406D mm)
Weight—20 lbs (9.1 kg)