EN
Patton electronic logo
Official user manual

Patton electronic 49040

59 pages·860 KB·Universal Remote·PDF·ENDEFRITNLJA
Patton electronic 49040
Table of Contents 104 sections Summary Table of Contents · Table of Contents · List of Figures · List of Tables · … ShowHide
Summary Table of Contentsp.3Table of Contentsp.4List of Figuresp.7List of Tablesp.8About this guidep.9Audiencep.9Structurep.9Precautionsp.10Safety when working with electricityp.11General observationsp.12Typographical conventions used in this documentp.12General conventionsp.12Chapter 1 General informationp.13SmartNode 4940 overviewp.14SN4940 model codesp.15SN4941 model codesp.15SmartNode 4940 rear panelp.16SmartNode 4940 front panelp.18Chapter 2 Applications overviewp.20Introductionp.21Application-Convert Legacy PBX to VoIPp.21Chapter 3 SmartNode installationp.22Planning the installationp.23Site logp.23Network informationp.23Network Diagramp.23IP related informationp.23Software toolsp.24AC Power Mainsp.24Location and mounting requirementsp.24Installing the gatewayp.24Placing the SmartNodep.24Installing cablesp.24Connecting the PRIp.25Connecting the 10/100/1000Base-T Ethernet cablep.25Connecting the power supplyp.26Chapter 4 Initial configurationp.27Introductionp.28Configuring the desired IP addressp.28Factory-default IP settingsp.28Connecting the SmartNode to the networkp.28Loading the configuration (optional)p.29Bootloaderp.30Start Bootloaderp.30Start-up with factory configurationp.30Load a new application image (SmartWare) via TFTPp.30Load a new application image (SmartWare) via the serial linkp.32Additional informationp.33Chapter 5 Contacting Patton for assistancep.34Introductionp.35Contact informationp.35Patton support headquarters in the USAp.35Alternate Patton support for Europe, Middle East, and Africa (EMEA)p.35Warranty Service and Returned Merchandise Authorizations (RMAs)p.35Warranty coveragep.35Out-of-warranty servicep.36Returns for creditp.36Return for credit policyp.36RMA numbersp.36Shipping instructionsp.36Appendix A Compliance informationp.37Compliancep.38EMCp.38Safetyp.38PSTN Regulatoryp.38Radio and TV Interferencep.38FCC Part 68 (ACTA) Statementp.39Industry Canada Noticep.39CE Declaration of Conformityp.40Authorized European Representativep.40Appendix B Specificationsp.41Voice connectivityp.42Data connectivityp.42Voice processing (signalling dependent)p.42Fax and modem supportp.42Voice signallingp.43Voice routing-session routerp.43IP servicesp.43Managementp.44Systemp.44Physicalp.44Identification of the SmartNode devices via SNMPp.45Appendix C Cablingp.47Introductionp.48Consolep.48Ethernetp.49E1 PRIp.50T1 PRIp.51Appendix D Port pin-outsp.52Introductionp.53Console portp.53Ethernetp.53PRI portp.54Appendix E SmartNode 4940 factory configurationp.55Introductionp.56Appendix F End user license agreementp.57End User License Agreementp.581. Definitionsp.582. Titlep.583. Termp.584. Grant of Licensep.585. Warrantyp.586. Terminationp.597. Other licensesp.59
Page 1 of the Patton electronic 49040 user manual — For Quick
Page 1 · click to enlarge
Page 1

For Quick

Start Installation

SmartNode 4940 Series Multi-Port T1/E1/PRI Enterprise VoIP Media Gateway

User Manual

Patton electronic 49040 — For Quick diagram (page 1)
Fig. 1 · For Quick
Sales Office+1 (301) 975-1000 Technical Support: +1 (301) 975-1007
E-mailsupport@ patton.com
WWWwww.patton.com
Part Number07MSN4940-GS, Rev. B
RevisedFebruary 7, 2012
Page 2 of the Patton electronic 49040 user manual
Page 2 · click to enlarge
Page 2

Patton Electronics Company, Inc.

7622 Rickenbacker Drive Gaithersburg, MD 20879 USA

Tel+1 (301) 975-1000 Fax: +1 (301) 869-9293 Support: +1 (301) 975-1007
Webwww.patton.com E-mail: support@ patton.com

Trademark Statement The terms SmartNode and SmartWare are trademarks of Patton Electronics Company. All other trademarks presented in this document are the property of their respective owners.

Copyright © 2012, Patton Electronics Company. All rights reserved. The information in this document is subject to change without notice. Patton Elec- tronics assumes no liability for errors that may appear in this document.

Warranty Information The software described in this document is furnished under a license and may be used or copied only in accordance with the terms of such license. For information about the license, see Appendix F, "End user license agreement" on page 57 or go to www.patton.com.

Patton Electronics warrants all SmartNode router components to be free from defects, and will—at our option—repair or replace the product should it fail within one year from the first date of the shipment.

This warranty is limited to defects in workmanship or materials, and does not cover customer damage, abuse or unauthorized modification. If the product fails to perform as warranted, your sole recourse shall be repair or replacement as described above. Under no condition shall Patton Electronics be liable for any damages incurred by the use of this product. These damages include, but are not limited to, the following: lost profits, lost savings and incidental or consequential damages arising from the use of or inability to use this product. Patton Electronics specifically disclaims all other warran- ties, expressed or implied, and the installation or use of this product shall be deemed an acceptance of these terms by the user.

Page 3 of the Patton electronic 49040 user manual — Summary Table of Contents
Page 3 · click to enlarge
Page 3

Summary Table of Contents

1 General information 13

2 Applications overview 20

3 SmartNode installation 22

4 Initial configuration 27

5 Contacting Patton for assistance 34

A Compliance information 37

B Specifications 41

C Cabling 47

D Port pin-outs 52

E SmartNode 4940 factory configuration 55

F End user license agreement 57

Page 4 of the Patton electronic 49040 user manual — Table of Contents
Page 4 · Contents
Contents

Contents

Summary Table of Contentsp.3Table of Contentsp.4List of Figuresp.7List of Tablesp.8About this guidep.9Audiencep.9Structurep.9Precautionsp.10Safety when working with electricityp.11General observationsp.12Typographical conventions used in this documentp.12General conventionsp.12Chapter 1 General informationp.13SmartNode 4940 overviewp.14SN4940 model codesp.15SN4941 model codesp.15SmartNode 4940 rear panelp.16SmartNode 4940 front panelp.18Chapter 2 Applications overviewp.20Introductionp.21Application-Convert Legacy PBX to VoIPp.21Chapter 3 SmartNode installationp.22Planning the installationp.23Site logp.23Network informationp.23Network Diagramp.23IP related informationp.23Software toolsp.24AC Power Mainsp.24Location and mounting requirementsp.24Installing the gatewayp.24Placing the SmartNodep.24Installing cablesp.24Connecting the PRIp.25Connecting the 10/100/1000Base-T Ethernet cablep.25Connecting the power supplyp.26Chapter 4 Initial configurationp.27Introductionp.28Configuring the desired IP addressp.28Factory-default IP settingsp.28Connecting the SmartNode to the networkp.28Loading the configuration (optional)p.29Bootloaderp.30Start Bootloaderp.30Start-up with factory configurationp.30Load a new application image (SmartWare) via TFTPp.30Load a new application image (SmartWare) via the serial linkp.32Additional informationp.33Chapter 5 Contacting Patton for assistancep.34Introductionp.35Contact informationp.35Patton support headquarters in the USAp.35Alternate Patton support for Europe, Middle East, and Africa (EMEA)p.35Warranty Service and Returned Merchandise Authorizations (RMAs)p.35Warranty coveragep.35Out-of-warranty servicep.36Returns for creditp.36Return for credit policyp.36RMA numbersp.36Shipping instructionsp.36Appendix A Compliance informationp.37Compliancep.38EMCp.38Safetyp.38PSTN Regulatoryp.38Radio and TV Interferencep.38FCC Part 68 (ACTA) Statementp.39Industry Canada Noticep.39CE Declaration of Conformityp.40Authorized European Representativep.40Appendix B Specificationsp.41Voice connectivityp.42Data connectivityp.42Voice processing (signalling dependent)p.42Fax and modem supportp.42Voice signallingp.43Voice routing-session routerp.43IP servicesp.43Managementp.44Systemp.44Physicalp.44Identification of the SmartNode devices via SNMPp.45Appendix C Cablingp.47Introductionp.48Consolep.48Ethernetp.49E1 PRIp.50T1 PRIp.51Appendix D Port pin-outsp.52Introductionp.53Console portp.53Ethernetp.53PRI portp.54Appendix E SmartNode 4940 factory configurationp.55Introductionp.56Appendix F End user license agreementp.57End User License Agreementp.581. Definitionsp.582. Titlep.583. Termp.584. Grant of Licensep.585. Warrantyp.586. Terminationp.597. Other licensesp.59
Page 7 of the Patton electronic 49040 user manual — List of Figures
Page 7 · click to enlarge
Page 7

List of Figures

1 SmartNode 4940 14 2 SN4940 rear panel 16 3 SmartNode 4940 front panel 18 4 Internet telephony IAD application 21 5 Power connector location on rear panel 26 6 Connecting the SmartNode to the network 29 7 Connecting a serial terminal 48 8 Typical Ethernet straight-through cable diagram for 10/100Base-T 49 9 Typical Ethernet straight-through cable diagram for 1000Base-T 49 10 Connecting an E1 PRI port to an NT1 50 11 E1 PRI port crossover cable 50 12 Connecting a T1 PRI port to an NT device 51 13 T1 PRI crossover cable 51 14 EIA-561 (RJ-45 8-pin) port 53

Page 8 of the Patton electronic 49040 user manual — List of Tables
Page 8 · click to enlarge
Page 8

List of Tables

1 General conventions 12 2 SmartNode 4940 PRI Ports and Voice Channels 15 3 Rear panel ports 17 4 SN4940 Front and Rear panel LEDs 19 5 Sample site log entries 23 6 Factory default IP address and network mask configuration 28 7 SmartNode Models and their Unique sysObjectID 45 8 RJ45 socket 10/100Base-T 53 9 RJ45 socket 1000Base-T 54 10 RJ-45 socket 54

Page 9 of the Patton electronic 49040 user manual — Structure
Page 9 · click to enlarge
Page 9

About this guide

This guide describes the SmartNode 4940 hardware, installation and basic configuration. For detailed software configuration information refer to the SmartWare Software Configuration Guide and the available Configura- tion Notes.

Audience

This guide is intended for the following users:

  • Operators
  • Installers
  • Maintenance technicians

Structure

This guide contains the following chapters and appendices:

  • Chapter 1 on page 13 provides information about router features and capabilities
  • Chapter 2 on page 20 contains an overview describing router operation and applications
  • Chapter 3 on page 22 provides hardware installation procedures
  • Chapter 4 on page 27 provides quick-start procedures for configuring the SmartNode router
  • Chapter 5 on page 34 contains information on contacting Patton technical support for assistance
  • Appendix A on page 37 contains compliance information for the router
  • Appendix B on page 41 contains specifications for the routers
  • Appendix C on page 47 provides cable recommendations
  • Appendix D on page 52 describes the router’s ports and pin-outs
  • Appendix E on page 55 lists the factory configuration settings for SmartNode 4940
  • Appendix F on page 57 provides license information that describes acceptable usage of the software provided with the SmartNode 4940 For best results, read the contents of this guide before you install the router.
Page 10 of the Patton electronic 49040 user manual — WARNING
Page 10 · click to enlarge
Page 10

SmartNode 4940 User Manual

Precautions

The alert symbol and IMPORTANT heading calls attention to important information.

IMPORTANT

The alert symbol and CAUTION heading indicate a potential haz- ard. Strictly follow the instructions to avoid property damage.

CAUTION

The shock hazard symbol and CAUTION heading indicate a potential electric shock hazard. Strictly follow the instructions to avoid property damage caused by electric shock.

CAUTION

The alert symbol and WARNING heading indicate a potential safety hazard. Strictly follow the warning instructions to avoid personal injury.

WARNING

The shock hazard symbol and WARNING heading indicate a potential electric shock hazard. Strictly follow the warning instructions to avoid injury caused by electric shock.

WARNING

Page 11 of the Patton electronic 49040 user manual — WARNING
Page 11 · click to enlarge
Page 11

SmartNode 4940 User Manual

Safety when working with electricity

  • Do not open the device when the power cord is connected. For systems without a power switch and without an external power adapter, line voltages are present within the device when the power cord is connected.
  • For devices with an external power adapter, the power adapter shall be a listed Limited Power Source The mains outlet that is utilized to power the device shall be within 10 feet (3 meters) of the device, shall be easily accessible, and protected by a circuit breaker in compliance with local regulatory requirements.
  • For AC powered devices, ensure that the power cable used meets all applicable standards for the country in which it is to be installed.
  • For AC powered devices which have 3 conductor power plugs (L1, L2 & GND or Hot, Neutral & Safety/Protective Ground), the wall outlet (or socket) must have an earth ground.
  • For DC powered devices, ensure that the interconnecting cables are rated for proper voltage, current, anticipated temperature, flammability, and mechanical serviceability.
  • WAN, LAN & PSTN ports (connections) may have hazardous voltages present regardless of whether the device is powered ON or OFF. PSTN relates to interfaces such as telephone lines, FXS, FXO, DSL, xDSL, T1, E1, ISDN, Voice, etc. These are known as “hazardous network voltages” and to avoid electric shock use caution when working near these ports. When disconnecting cables for these ports, detach the far end connection first.
  • Do not work on the device or connect or disconnect cables during periods of lightning activity

WARNING

This device contains no user serviceable parts. This device can only be repaired by qualified service personnel.

WARNING

In accordance with the requirements of council directive 2002/ 96/EC on Waste of Electrical and Electronic Equipment (WEEE), ensure that at end-of-life you separate this product from other waste and scrap and deliver to the WEEE collection system in your country for recycling.

Page 12 of the Patton electronic 49040 user manual — Typographical conventions used in this document
Page 12 · click to enlarge
Page 12

SmartNode 4940 User Manual

Always follow ESD prevention procedures when removing and replacing cards.

CAUTION

Wear an ESD-preventive wrist strap, ensuring that it makes good skin contact. Connect the clip to an unpainted surface of the chassis frame to safely channel unwanted ESD voltages to ground.

To properly guard against ESD damage and shocks, the wrist strap and cord must operate effectively. If no wrist strap is avail- able, ground yourself by touching the metal part of the chassis.

  • General observations
  • Clean the case with a soft slightly moist anti-static cloth
  • Place the unit on a flat surface and ensure free air circulation
  • Avoid exposing the unit to direct sunlight and other heat sources
  • Protect the unit from moisture, vapors, and corrosive liquids

Typographical conventions used in this document

This section describes the typographical conventions and terms used in this guide.

General conventions The procedures described in this manual use the following text conventions:

Table 1. General conventions

ConventionMeaning Garamond blue typeIndicates a cross-reference hyperlink that points to a figure, graphic, table, or section heading. Clicking on the hyperlink jumps you to the reference. When you have finished reviewing the reference, click on the Go to Previous View button in the Adobe® Acrobat® Reader toolbar to return to your starting point. Futura bold typeCommands and keywords are in boldface font. Futura bold-italic typeParts of commands, which are related to elements already named by the user, are in boldface italic font. Italicized Futura typeVariables for which you supply values are in italic font Futura typeIndicates the names of fields or windows. Garamond bold typeIndicates the names of command buttons that execute an action. < >Angle brackets indicate function and keyboard keys, such as <SHIFT>, <CTRL>, <C>, and so on. [ ]Elements in square brackets are optional. {a | b | c}Alternative but required keywords are grouped in braces ({ }) and are separated by vertical bars ( | ) screenTerminal sessions and information the system displays are in screen font. nodeThe leading IP address or nodename of a SmartNode is substituted with node in boldface italic font. SNThe leading SN on a command line represents the nodename of the SmartNode #An hash sign at the beginning of a line indicates a comment line.
Page 13 of the Patton electronic 49040 user manual — Table of contents
Page 13 · click to enlarge
Page 13

Table of contents

Summary Table of Contentsp.3Table of Contentsp.4List of Figuresp.7List of Tablesp.8About this guidep.9Audiencep.9Structurep.9Precautionsp.10Safety when working with electricityp.11General observationsp.12Typographical conventions used in this documentp.12General conventionsp.12Chapter 1 General informationp.13SmartNode 4940 overviewp.14SN4940 model codesp.15SN4941 model codesp.15SmartNode 4940 rear panelp.16SmartNode 4940 front panelp.18Chapter 2 Applications overviewp.20Introductionp.21Application-Convert Legacy PBX to VoIPp.21Chapter 3 SmartNode installationp.22Planning the installationp.23Site logp.23Network informationp.23Network Diagramp.23IP related informationp.23Software toolsp.24AC Power Mainsp.24Location and mounting requirementsp.24Installing the gatewayp.24Placing the SmartNodep.24Installing cablesp.24Connecting the PRIp.25Connecting the 10/100/1000Base-T Ethernet cablep.25Connecting the power supplyp.26Chapter 4 Initial configurationp.27Introductionp.28Configuring the desired IP addressp.28Factory-default IP settingsp.28Connecting the SmartNode to the networkp.28Loading the configuration (optional)p.29Bootloaderp.30Start Bootloaderp.30Start-up with factory configurationp.30Load a new application image (SmartWare) via TFTPp.30Load a new application image (SmartWare) via the serial linkp.32Additional informationp.33Chapter 5 Contacting Patton for assistancep.34Introductionp.35Contact informationp.35Patton support headquarters in the USAp.35Alternate Patton support for Europe, Middle East, and Africa (EMEA)p.35Warranty Service and Returned Merchandise Authorizations (RMAs)p.35Warranty coveragep.35Out-of-warranty servicep.36Returns for creditp.36Return for credit policyp.36RMA numbersp.36Shipping instructionsp.36Appendix A Compliance informationp.37Compliancep.38EMCp.38Safetyp.38PSTN Regulatoryp.38Radio and TV Interferencep.38FCC Part 68 (ACTA) Statementp.39Industry Canada Noticep.39CE Declaration of Conformityp.40Authorized European Representativep.40Appendix B Specificationsp.41Voice connectivityp.42Data connectivityp.42Voice processing (signalling dependent)p.42Fax and modem supportp.42Voice signallingp.43Voice routing-session routerp.43IP servicesp.43Managementp.44Systemp.44Physicalp.44Identification of the SmartNode devices via SNMPp.45Appendix C Cablingp.47Introductionp.48Consolep.48Ethernetp.49E1 PRIp.50T1 PRIp.51Appendix D Port pin-outsp.52Introductionp.53Console portp.53Ethernetp.53PRI portp.54Appendix E SmartNode 4940 factory configurationp.55Introductionp.56Appendix F End user license agreementp.57End User License Agreementp.581. Definitionsp.582. Titlep.583. Termp.584. Grant of Licensep.585. Warrantyp.586. Terminationp.597. Other licensesp.59
Page 14 of the Patton electronic 49040 user manual — SmartNode 4940 overview
Page 14 · click to enlarge
Page 14

SmartNode 4940 User Manual 1 • General information

SmartNode 4940 overview

As enterprises move toward unified communications, the SmartNode™ 4940 Enterprise VoIP Media Gate- way (see figure 1) provides a smooth transition by either IP-enabling traditional PBX systems for SIP trunking over existing Internet connection, adding PSTN-breakout for number portability, or enabling PSTN access for IP PBX and unified communications systems. Preserve investment in legacy phone equipment while taking the next step toward unified communications with Patton’s proven SmartNode™ VoIP solutions. .

Patton electronic 49040 — SmartNode 4940 overview diagram (page 14)
Fig. 2 · SmartNode 4940 overview

Figure 1. SmartNode 4940

The SmartNode 4940 performs the following major functions:

  • Up to 120 VoIP Calls —With four T1/E1/PRI ports and one Gigabit Ethernet port.
  • Proven Interoperability —Interoperable with all the major-brand softswitches and IP-PBXs.
  • Comprehensive Signaling Protocol Support —Supports SIP, H.323, ISDN, and T1/E1 telephony—plus T.38 and SuperG3 FAX—over TDM/PSTN and IP/Ethernet services simultaneously.
  • Transparent Telephony Features —Complex number manipulation and mapping for seamless integration with existing infrastructures, CLIP, CLIR, hold, transfer and much more.
  • High Precision Clock —Delivers DECT PBX interoperability with reliable fax performance.

SmartNode 4940 overview 14

Page 15 of the Patton electronic 49040 user manual — SN4940/1E24V/EUI 1 24
Page 15 · click to enlarge
Page 15

SmartNode 4940 User Manual 1 • General information

SN4940 model codes The SmartNode 4940 series consists of several models. They differ in the number of PRI ports and voice chan- nels supported. All models come equipped with one 10/100/1000Base-T Ethernet port. The SmartNode 4940 PRI ports and voice channels are listed in table 2.

Table 2. SmartNode 4940 PRI Ports and Voice Channels

Model PRI Ports Voice Channels

SN4940/1E24V/EUI 1 24

SN4940/1E30V/EUI 1 30

SN4940/4E24V/EUI 4 24

SN4940/4E30V/EUI 4 30

SN4940/4E48V/EUI 4 48

SN4940/4E60V/EUI 4 60

SN4940/4E96V/EUI 4 96

SN4940/4E120V/EUI 4 120

SN4941 model codes The high precision SmartNode 4941 models have a Stratum III clock. The Stratum III clock provides a clock source of < 5 ppm. For PBXs that used to rely on PSTN for accurate clock source, the SmartNode 4941 can provide a PSTN-equivalent high precision clock. The popular DECT PBX needs such high precision clocks.

SmartNode 4940 overview 15

Page 16 of the Patton electronic 49040 user manual — SmartNode 4940 rear panel
Page 16 · click to enlarge
Page 16

SmartNode 4940 User Manual 1 • General information

SmartNode 4940 rear panel

The SmartNode 4940 rear panel ports are described in table 3.

Patton electronic 49040 — SmartNode 4940 rear panel diagram (page 16)
Fig. 3 · SmartNode 4940 rear panel

Figure 2. SN4940 rear panel

SmartNode 4940 rear panel 16

Page 17 of the Patton electronic 49040 user manual — SmartNode 4940 rear panel
Page 17 · click to enlarge
Page 17

SmartNode 4940 User Manual 1 • General information

Table 3. Rear panel ports

ETH 0/0 Auto-MDX Gigabit-Ethernet port, RJ-45 (see figure 2), connects the unit to an Ethernet WAN device (for example, a cable modem, DSL modem, or fiber modem). Note: Only full duplex modes are supported.

PRI 0/0 RJ-45 connector providing E1 (2.048Mbps) or T1(1.533 Mbps) PRI interface, meet- ing all requirements of ITU-T recommendations for G.703. Use a shielded E1 or T1 interface cable for 120 Ohm balanced connections to connect the SmartNode with an NT or ET, e.g. a PBX or LE.

PRI 0/1 RJ-45 connector providing E1 (2.048Mbps) or T1(1.533 Mbps) PRI interface, meet- ing all requirements of ITU-T recommendations for G.703. Use a shielded E1 or T1 interface cable for 120 Ohm balanced connections to connect the SmartNode with an NT or ET, e.g. a PBX or LE.

PRI 0/2 RJ-45 connector providing E1 (2.048Mbps) or T1(1.533 Mbps) PRI interface, meet- ing all requirements of ITU-T recommendations for G.703. Use a shielded E1 or T1 interface cable for 120 Ohm balanced connections to connect the SmartNode with an NT or ET, e.g. a PBX or LE.

PRI 0/3 RJ-45 connector providing E1 (2.048Mbps) or T1(1.533 Mbps) PRI interface, meet- ing all requirements of ITU-T recommendations for G.703. Use a shielded E1 or T1 interface cable for 120 Ohm balanced connections to connect the SmartNode with an NT or ET, e.g. a PBX or LE.

Console Used for service and maintenance, the Console port (see figure 2), an RS-232 RJ-45 connector, connects the product to a serial terminal such as a PC or ASCII terminal (also called a dumb terminal).

DC power input Electricity supply socket. (see figure 2).

  • Reset The reset button (see figure 2 ) has three functions:
  • Restart the unit with the current startup configuration—Press (for less than 1 second) and release the Reset button to restart the unit with the current startup configuration.
  • Restart the unit with factory default configuration—Press the Reset button for 5 seconds until the Power LED (see figure 3 on page 18) starts blinking to restart the unit with factory default configuration.
  • Restart the unit in bootloader mode (to be used only by trained SmartNode technicians)—Starting with the unit powered off, press and hold the Reset button as you apply power to the unit. Release the Reset button when the Power LED starts blinking so the unit will enter bootloader mode.

SmartNode 4940 rear panel 17

Port Description

Page 18 of the Patton electronic 49040 user manual — SmartNode 4940 front panel
Page 18 · click to enlarge
Page 18

SmartNode 4940 User Manual 1 • General information

SmartNode 4940 front panel

Figure 3 shows SmartNode 4940 front panel LEDs, the LED definitions are listed in table 4.

Patton electronic 49040 — SmartNode 4940 front panel diagram (page 18)
Fig. 4 · SmartNode 4940 front panel

SmartNode 4940 Multi-Port T1/E1/PRI VoIP Enterprise VoIP Media Gateway

Figure 3. SmartNode 4940 front panel

SmartNode 4940 front panel 18

Page 19 of the Patton electronic 49040 user manual — SmartNode 4940 front panel
Page 19 · click to enlarge
Page 19

SmartNode 4940 User Manual 1 • General information

Table 4. SN4940 Front and Rear panel LEDs

Power When lit, indicates power is applied.

Run When lit, the unit is in normal operation. Flashes once per second during boot (startup).

VoIP Link • On indicates the gateway is registered to an H.323 gatekeeper/SIP server, or, in the case of direct routing, has at least one active VoIP connection.

  • Off indicates the unit is not configured or registered, or has no active directrouted VoIP connection.
  • Flashing green indicates that the unit is attempting to register or has failed to register.

Ethernet Link • On when the Ethernet connection on the corresponding port has a link indication.

Ethernet Speed 10/100 When the Ethernet Link LED is on, then:

  • On when the Ethernet is connected to a 100Mb network.
  • Off when the Ethernet is connected to a 10Mb network.

Ethernet Speed 1000 • On when the Ethernet is connected to a 1000Mb network.

Ethernet Activity • Flashes when data is received or transmitted at the corresponding Ethernet port.

PRI Link/Status • On = in frame, no errors

  • Flash = Error
  • Fast Flash = Signal detected but no frame synchronization or aquisition is in process
  • Slow Flash = Framing synchronized, Signaling not established

SmartNode 4940 front panel 19

LED Description

Page 20 of the Patton electronic 49040 user manual — Chapter contents
Page 20 · click to enlarge
Page 20

Chapter 2 Applications overview

Chapter contents

Introduction 21 Application—Convert Legacy PBX to VoIP 21

Page 21 of the Patton electronic 49040 user manual — Application—Convert Legacy PBX to VoIP
Page 21 · click to enlarge
Page 21

SmartNode 4940 User Manual 2 • Applications overview

Introduction

Patton’s SmartNode Enterprise VoIP Media Gateways deliver the features you need for advanced multiservice voice and data network applications. They combine high quality voice-over-IP with powerful quality of service routing functions to build professional and reliable VoIP and data networks. This chapter describes typical applications for which this SmartNode is uniquely suited.

Application—Convert Legacy PBX to VoIP

The SmartNode 4940 Series can be used to make and receive calls to and from the public ISDN network and Internet Telephony services on any ISDN Terminal (Phone or PBX) (see figure 4). Using individually config- urable routing tables, an outbound call can be directed to the local PSTN connection or to an Internet tele- phony service provider (ISTP). Inbound calls from the Internet and the PSTN can ring the same phone.

Patton electronic 49040 — Application—Convert Legacy PBX to VoIP diagram (page 21)
Fig. 5 · Application—Convert Legacy PBX to VoIP

Figure 4. Internet telephony IAD application

For an installation where there are existing routers and access modems, the SN4940 is a cost-effective solution to bring SIP-trunking service to a traditional PBX. .

Introduction 21

Page 22 of the Patton electronic 49040 user manual — Table of contents
Page 22 · click to enlarge
Page 22

Table of contents

Summary Table of Contentsp.3Table of Contentsp.4List of Figuresp.7List of Tablesp.8About this guidep.9Audiencep.9Structurep.9Precautionsp.10Safety when working with electricityp.11General observationsp.12Typographical conventions used in this documentp.12General conventionsp.12Chapter 1 General informationp.13SmartNode 4940 overviewp.14SN4940 model codesp.15SN4941 model codesp.15SmartNode 4940 rear panelp.16SmartNode 4940 front panelp.18Chapter 2 Applications overviewp.20Introductionp.21Application-Convert Legacy PBX to VoIPp.21Chapter 3 SmartNode installationp.22Planning the installationp.23Site logp.23Network informationp.23Network Diagramp.23IP related informationp.23Software toolsp.24AC Power Mainsp.24Location and mounting requirementsp.24Installing the gatewayp.24Placing the SmartNodep.24Installing cablesp.24Connecting the PRIp.25Connecting the 10/100/1000Base-T Ethernet cablep.25Connecting the power supplyp.26Chapter 4 Initial configurationp.27Introductionp.28Configuring the desired IP addressp.28Factory-default IP settingsp.28Connecting the SmartNode to the networkp.28Loading the configuration (optional)p.29Bootloaderp.30Start Bootloaderp.30Start-up with factory configurationp.30Load a new application image (SmartWare) via TFTPp.30Load a new application image (SmartWare) via the serial linkp.32Additional informationp.33Chapter 5 Contacting Patton for assistancep.34Introductionp.35Contact informationp.35Patton support headquarters in the USAp.35Alternate Patton support for Europe, Middle East, and Africa (EMEA)p.35Warranty Service and Returned Merchandise Authorizations (RMAs)p.35Warranty coveragep.35Out-of-warranty servicep.36Returns for creditp.36Return for credit policyp.36RMA numbersp.36Shipping instructionsp.36Appendix A Compliance informationp.37Compliancep.38EMCp.38Safetyp.38PSTN Regulatoryp.38Radio and TV Interferencep.38FCC Part 68 (ACTA) Statementp.39Industry Canada Noticep.39CE Declaration of Conformityp.40Authorized European Representativep.40Appendix B Specificationsp.41Voice connectivityp.42Data connectivityp.42Voice processing (signalling dependent)p.42Fax and modem supportp.42Voice signallingp.43Voice routing-session routerp.43IP servicesp.43Managementp.44Systemp.44Physicalp.44Identification of the SmartNode devices via SNMPp.45Appendix C Cablingp.47Introductionp.48Consolep.48Ethernetp.49E1 PRIp.50T1 PRIp.51Appendix D Port pin-outsp.52Introductionp.53Console portp.53Ethernetp.53PRI portp.54Appendix E SmartNode 4940 factory configurationp.55Introductionp.56Appendix F End user license agreementp.57End User License Agreementp.581. Definitionsp.582. Titlep.583. Termp.584. Grant of Licensep.585. Warrantyp.586. Terminationp.597. Other licensesp.59
Page 23 of the Patton electronic 49040 user manual — Planning the installation
Page 23 · click to enlarge
Page 23

SmartNode 4940 User Manual 3 • SmartNode installation

Planning the installation

Before installing the gateway router device, the following tasks should be completed:

  • Create a network diagram (see section “Network information” on page 23)
  • Gather IP related information (see section “IP related information” on page 23 for more information)
  • Install the hardware and software needed to configure the SmartNode . (See section “Software tools” on page 24)
  • Verify power source reliability (see section “Power source” on page 26).

After you have finished preparing for gateway router installation, go to section “Installing the gateway” on page 24 to install the device.

Site log Patton recommends that you maintain a site log to record all actions relevant to the system, if you do not already keep such a log. Site log entries should include information such as listed in table 5.

Table 5. Sample site log entries

Installation Make a copy of the installation checklist and insert it into the site log

Upgrades and maintenance Use the site log to record ongoing maintenance and expansion history

Configuration changes Record all changes and the reasons for them

Maintenance Schedules, requirements, and procedures performed

Comments Notes, and problems

Software Changes and updates to SmartWare software

Network information Network connection considerations that you should take into account for planning are provided for several types of network interfaces are described in the following sections.

Network Diagram Draw a network overview diagram that displays all neighboring IP nodes, connected elements and telephony components.

IP related information Before you can set up the basic IP connectivity for your SmartNode 4940 you should have the following infor- mation:

  • IP addresses used for Ethernet port
  • Subnet mask used for Ethernet port

Planning the installation 23

Entry Description

Page 24 of the Patton electronic 49040 user manual — WARNING
Page 24 · click to enlarge
Page 24

SmartNode 4940 User Manual 3 • SmartNode installation

  • IP addresses of central H.323 gatekeeper (if used)
  • IP addresses and/or URL of SIP servers or Internet telephony services (if used)
  • Login and password for SIP or H.323 based telephony services
  • IP addresses of central TFTP server used for configuration upload and download (optional)

Software tools You will need a PC (or equivalent) with Windows Telnet or a program such as Tera Term Pro Web to config- ure the software on your SmartNode router.

AC Power Mains If you suspect that your AC power is not reliable, for example if room lights flicker often or there is machinery with large motors nearby, have a qualified professional test the power. Patton recommends that you include an uninterruptible power supply (UPS) in the installation to ensure that VoIP service is not impaired if the power fails. Refer to “Connecting the power supply” on page 26.

Location and mounting requirements The SmartNode router is intended to be placed on a desktop or similar sturdy, flat surface that offers easy access to the cables. Allow sufficient space at the rear of the chassis for cable connections. Additionally, you should consider the need to access the unit for future upgrades and maintenance.

Installing the gateway SmartNode hardware installation consists of the following:

  • Placing the device at the desired installation location (see section “Placing the SmartNode” on page 24)
  • Connecting the interface and power cables (see section “Installing cables” )

When you finish installing the SmartNode, go to chapter 4, “Initial configuration” on page 27.

Placing the SmartNode Place the unit on a desktop or similar sturdy, flat surface that offers easy access to the cables. The unit should be installed in a dry environment with sufficient space to allow air circulation for cooling.

Installing cables

Do not work on the system or connect or disconnect cables during periods of lightning activity.

WARNING

Installing the gateway 24

Page 25 of the Patton electronic 49040 user manual — Connecting the PRI
Page 25 · click to enlarge
Page 25

SmartNode 4940 User Manual 3 • SmartNode installation

Connect the cables in the following order:

The interconnecting cables shall be acceptable for external use and shall be rated for the proper application with respect to volt- age, current, anticipated temperature, flammability, and mechanical serviceability. CAUTION

1. Connect the T1/E1 cables to the PRI T1/E1 ports (see Appendix C on page 47 and Appendix D on page 52 ).
2. Connect the 10/100/1000Base-T Ethernet (see section “Connecting the 10/100/1000Base-T Ethernet cable” on page 25)
3. Connect the power mains cable (see section “Connecting the power supply” on page 26)

Connecting the PRI The SmartNode comes with one or four PRI ports. These ports are usually connected to a PBX or switch (local exchange (LE) ). Each PRI T1/E1 port is a RJ-48C receptacle. In most cases, a straight-through RJ-45 can be used to connect the PRI. Each port can be configured as NT (clock master) or TE (clock slave).

For details on the PRI port pin-out and ISDN cables, refer to Appendix C, “Cabling” on page 43 and Appen- dix D, “port pin-outs” on page 47.

Connecting the 10/100/1000Base-T Ethernet cable The SmartNode 4940 has automatic MDX (auto-crossover) detection and configuration on the Ethernet port. The port can be connected to a host or hub/switch with a straight-through or cross-over wired cable. Connect the LAN network to ETH 0/0.

For details on the Ethernet port pinout and cables, refer to Appendix C, “Cabling” on page 47 and Appendix D, “Port pin-outs” on page 52.

Installing the gateway 25

Page 26 of the Patton electronic 49040 user manual — RS-232
Page 26 · click to enlarge
Page 26

SmartNode 4940 User Manual 3 • SmartNode installation

Connecting the power supply

  • Do not connect power to the AC Mains at this time.
  • The external power adapter shall be a listed Limited Power Source.

CAUTION WARNING

  • The 4940 external power supply automatically adjusts to accept an input voltage from 100 to 240 VAC (50/60 Hz). Verify that the proper voltage is present before plugging the power cord into the receptacle. Failure to do so could result in equipment damage.
1. Insert the barrel type connector end of the AC power cord into the external power supply connector (see figure 5 ).
2. Insert the female end of the power cord into the internal power supply connector.

12V, 1.25A

3 2 1 0

T1/E1

0 ETH

ETH 0 10/100/1000Base-T port

RS-232

Figure 5. Power connector location on rear panel

3. Verify that the AC power cord included with your router is compatible with local standards. If it is not, refer to chapter 5, “Contacting Patton for assistance” on page 32 to find out how to replace it with a compatible power cord.
4. Connect the male end of the power cord to an appropriate power outlet.
5. Verify that the green Power LED is lit (see figure 5 ).

Installing the gateway 26

Show 7 more labels / short text on this page
– + · Power · T1/E1 Ports 0-3 · Reset · Console · Console RS-232 port · RESET button
Page 27 of the Patton electronic 49040 user manual — Table of contents
Page 27 · click to enlarge
Page 27

Table of contents

Summary Table of Contentsp.3Table of Contentsp.4List of Figuresp.7List of Tablesp.8About this guidep.9Audiencep.9Structurep.9Precautionsp.10Safety when working with electricityp.11General observationsp.12Typographical conventions used in this documentp.12General conventionsp.12Chapter 1 General informationp.13SmartNode 4940 overviewp.14SN4940 model codesp.15SN4941 model codesp.15SmartNode 4940 rear panelp.16SmartNode 4940 front panelp.18Chapter 2 Applications overviewp.20Introductionp.21Application-Convert Legacy PBX to VoIPp.21Chapter 3 SmartNode installationp.22Planning the installationp.23Site logp.23Network informationp.23Network Diagramp.23IP related informationp.23Software toolsp.24AC Power Mainsp.24Location and mounting requirementsp.24Installing the gatewayp.24Placing the SmartNodep.24Installing cablesp.24Connecting the PRIp.25Connecting the 10/100/1000Base-T Ethernet cablep.25Connecting the power supplyp.26Chapter 4 Initial configurationp.27Introductionp.28Configuring the desired IP addressp.28Factory-default IP settingsp.28Connecting the SmartNode to the networkp.28Loading the configuration (optional)p.29Bootloaderp.30Start Bootloaderp.30Start-up with factory configurationp.30Load a new application image (SmartWare) via TFTPp.30Load a new application image (SmartWare) via the serial linkp.32Additional informationp.33Chapter 5 Contacting Patton for assistancep.34Introductionp.35Contact informationp.35Patton support headquarters in the USAp.35Alternate Patton support for Europe, Middle East, and Africa (EMEA)p.35Warranty Service and Returned Merchandise Authorizations (RMAs)p.35Warranty coveragep.35Out-of-warranty servicep.36Returns for creditp.36Return for credit policyp.36RMA numbersp.36Shipping instructionsp.36Appendix A Compliance informationp.37Compliancep.38EMCp.38Safetyp.38PSTN Regulatoryp.38Radio and TV Interferencep.38FCC Part 68 (ACTA) Statementp.39Industry Canada Noticep.39CE Declaration of Conformityp.40Authorized European Representativep.40Appendix B Specificationsp.41Voice connectivityp.42Data connectivityp.42Voice processing (signalling dependent)p.42Fax and modem supportp.42Voice signallingp.43Voice routing-session routerp.43IP servicesp.43Managementp.44Systemp.44Physicalp.44Identification of the SmartNode devices via SNMPp.45Appendix C Cablingp.47Introductionp.48Consolep.48Ethernetp.49E1 PRIp.50T1 PRIp.51Appendix D Port pin-outsp.52Introductionp.53Console portp.53Ethernetp.53PRI portp.54Appendix E SmartNode 4940 factory configurationp.55Introductionp.56Appendix F End user license agreementp.57End User License Agreementp.581. Definitionsp.582. Titlep.583. Termp.584. Grant of Licensep.585. Warrantyp.586. Terminationp.597. Other licensesp.59
Page 28 of the Patton electronic 49040 user manual — Connecting the SmartNode to the network
Page 28 · click to enlarge
Page 28

SmartNode 4940 User Manual 4 • Initial configuration

Introduction

This chapter leads you through the basic steps to set up a new SmartNode and to download a configuration. Setting up a new SmartNode consists of the following main steps:

  • Configuring the desired IP address
  • Connecting the SmartNode to the network
  • Loading the configuration (optional)

Configuring the desired IP address

Factory-default IP settings The factory default configuration for the Ethernet interface IP addresses and network masks are listed in table 6. The Ethernet 0/0 port uses the DHCP client to automatically assign the IP address and network mask.

Table 6. Factory default IP address and network mask configuration

IP Address Network Mask

Ethernet 0 (ETH 0/0) DHCP DHCP

Connecting the SmartNode to the network

The SmartNode 4940 Series is equipped with an Auto-MDX Ethernet port, so you can use straight-through or crossover cables for host or hub/switch connections (see figure 6).

The interconnecting cables shall be acceptable for external use and shall be rated for the proper application with respect to volt- age, current, anticipated temperature, flammability, and mechanical serviceability. CAUTION

Introduction 28

Page 29 of the Patton electronic 49040 user manual — Loading the configuration (optional)
Page 29 · click to enlarge
Page 29

SmartNode 4940 User Manual 4 • Initial configuration

Patton electronic 49040 — Loading the configuration (optional) diagram (page 29)
Fig. 6 · Loading the configuration (optional)

Figure 6. Connecting the SmartNode to the network

You can check the connection with the ping command from the SmartNode to another host on the network.

172.16.1.99(if-ip)[LAN]#ping

Loading the configuration (optional)

Patton provides a collection of configuration templates on the support page at www.patton.com/smart- node—one of which may be similar enough to your application that you can use it to speed up configuring the SmartNode. Simply download the configuration note that matches your application to your PC. Adapt the configuration as described in the configuration note to your network (remember to modify the IP address) and copy the modified configuration to a TFTP server. The SmartNode can now load its configuration from this server.

In this example we assume the TFTP server on the host with the IP address 172.16.1.11 and the configuration named SN.cfg in the root directory of the TFTP server.

172.16.1.99(if-ip)[WAN]#copy tftp://172.16.1.11/SN.cfg startup-config Download...100% 172.16.1.99(if-ip)[WAN]# After the SmartNode has been rebooted the new startup configuration will be activated.

Patton electronic 49040 — Loading the configuration (optional) diagram (page 29)
Fig. 7 · Loading the configuration (optional)

When you issue the reload command, the SmartNode will ask if you want to copy the running configuration to the startup con- figuration. Since you just downloaded a configuration file to the startup configuration you must answer this question with NO. Otherwise, the downloaded configuration will be overwritten and lost!

Loading the configuration (optional) 29

Page 30 of the Patton electronic 49040 user manual — Start-up with factory configuration
Page 30 · click to enlarge
Page 30

SmartNode 4940 User Manual 4 • Initial configuration

172.16.1.99(if-ip)[WAN]#reload Running configuration has been changed. Do you want to copy the 'running-config' to the 'startup-config'? Press 'yes' to store, 'no' to drop changes : no Press 'yes' to restart, 'no' to cancel : yes The system is going down

Bootloader

The bootloader ensures that basic operations, network access, and downloads are possible in case of interrupted or corrupted application image downloads. It offers console access to the Bootloader and the capability for downloading application images (e.g. SmartWare) via the serial link of the console.

Start Bootloader To start the Bootloader, power on the SmartNode while pressing the reset button. Open a Telnet session to the SmartNode via one of the Ethernet interfaces, or open a CLI session via the console port (if available on the SmartNode). The login display will appear. Using the credentials admin / patton , log in to the SmartNode. The following prompt will be displayed:

Type help to display an overview of the available commands.

Start-up with factory configuration

1 RedBoot> fis load Copies the SmartWare application image from the persistent memory (flash:) to the volatile memory (RAM) from where it will be executed.

2 RedBoot> go -s factory-config Starts the SmartWare application telling it to use ‘factory-config’ as startup configuration. You can also start-up with any other configuration available in the persistent memory (nvram:) by pro- viding its name instead of ‘factory-config’.

Load a new application image (SmartWare) via TFTP The following procedure downloads the application image (SmartWare) for the mainboard. See the note below on how to download the respective CLI description file.

RedBoot> ip_address - l local_ip_address [/mask_len]

Sets the IP address and subnet mask of the Ethernet interface 0/0 which shall be used to receive the new application image. mask_len is the length of the network address (or the number of 1’s within the subnet mask). See Note below.

Show 5 more labels / short text on this page
RedBoot> · Step Command Purpose · Step Command Purpose · 1 optional · Bootloader 30
Page 31 of the Patton electronic 49040 user manual — Bootloader
Page 31 · click to enlarge
Page 31

SmartNode 4940 User Manual 4 • Initial configuration

RedBoot> ip_address -g gateway Sets the IP address of the default gateway.

RedBoot> ping -h tftp-server_ip_address Tests the connectivity to the TFTP server.

4 RedBoot> load -r -v -h host -b base_address file_name

Downloads an application image into the vola- tile memory (RAM) from where the SmartNode could directly execute it. host: IP address of the TFTP server base_address: memory location where to store the application image. Use the default address 0x1800100 file_name: path and name of the file on the TFTP server. Note: use the image file that con- tains the whole application, not the image parts.

5 RedBoot> fis delete -n 1 Deletes the first application image. Reply with ‘y’ to the confirmation request.

6 RedBoot> fis create Stores the downloaded application image to the permanent memory (flash:). Reply with ‘y’ to the confirmation request.

7 RedBoot> fis list -l Checks whether the image has been success- fully stored, whether it is the desired Release and Build, and whether it is valid.

8 RedBoot> go Starts the application image that was down- loaded into the volatile memory (RAM).

Note With the Bootloader, only the Ethernet interface 0/0 is available. The Boot- loader applies the IP address, subnet mask, and default gateway that were last configured by the Bootloader itself or by another application (e.g. Smart- Ware). If an application configured the Ethernet interface 0/0 to use DHCP, the Bootloader will also use DHCP to learn the interface configuration. It can receive and apply the IP address, subnet mask, default gateway, and default (TFTP) server (transmitted as basic DHCP information ‘Next server IP address’).

ExampleDownloading and storing a new application image (SmartWare)

RedBoot> ip -l 172.16.40.98/19 RedBoot> ip -g 172.16.32.1 RedBoot> ping -h 172.16.32.100 Network PING - from 172.16.40.98 to 172.16.32.100 PING - received 10 of 10 expected

RedBoot> load -r -v -h 172.16.32.100 -b 0x1800100 /Sn4xxx/image.bin

Show 4 more labels / short text on this page
Step Command Purpose · 2 optional · 3 optional · Bootloader 31
Page 32 of the Patton electronic 49040 user manual — Load a new application image (SmartWare) via the serial link
Page 32 · click to enlarge
Page 32

SmartNode 4940 User Manual 4 • Initial configuration

Using default protocol (TFTP) - Raw file loaded 0x01800100-0x0199ca6b, 1689964 bytes, assumed entry at 0x01800100

RedBoot> fis delete -n 1 Delete image 1 - continue (y/n)? y ... Erase from 0x60030000-0x601cc974:

RedBoot> fis create Use address 0x01800100, size 1684402 ? - continue (y/n)? y ... Erase from 0x60030000-0x601cb3ba: Program from 0x00011eec-0x00011ef4 at 0x60030000: Program from 0x01800100-0x0199b4b2 at 0x60030008: Program from 0x00011eec-0x00011ef4 at 0x60030000: . Image successfully written to flash

RedBoot> fis list -l Id Address Length State Description Entry Load Addr Version 1 0x60030000 1693438 valid SmartWare R5.T BUILD28015 0x01800100 0x01800100 V5.T

RedBoot> go Starting 'SmartWare R5.T BUILD28015' at 0x01800100 via 0x01800100

Load a new application image (SmartWare) via the serial link The Bootloader supports the ‘X-Modem’ and ‘Y-Modem’ protocols to download application images via the serial link of the console. Do the following to initiate the download:

1 RedBoot> load -r -v -m { xmodem | ymodem } -b base_address

Downloads an application image into the volatile memory (RAM) from where the SmartNode could directly execute it. ‘xmodem’ or ‘ymodem’: Specify the protocol to be used, X- Modem or Y-Modem base_address: memory location where to store the application image. Use the default address 0x1800100 Execute the above RedBoot command first, then start the trans- fer from the terminal program with the command ‘Send file via X-Modem’ (or similar).

5 RedBoot> fis delete -n 1 Deletes the first application image. Reply with ‘y’ to the confirmation request.

6 RedBoot> fis create Stores the downloaded application image to the permanent memory (flash:). Reply with ‘y’ to the confirmation request.

7 RedBoot> fis list -l Checks whether the image has been successfully stored, whether it is the desired Release and Build, and whether it is valid.

Step Command Purpose · Bootloader 32

Page 33 of the Patton electronic 49040 user manual — Additional information
Page 33 · click to enlarge
Page 33

SmartNode 4940 User Manual 4 • Initial configuration

8 RedBoot> go Starts the application image that was downloaded to the vola- tile memory (RAM).

Additional information

For detailed information about configuring and operating guidance, set up procedures, and troubleshooting, refer to the SmartNode Series SmartWare Software Configuration Guide available online at www.patton.com/ manuals.

Step Command Purpose · Additional information 33

Page 34 of the Patton electronic 49040 user manual — Table of contents
Page 34 · click to enlarge
Page 34

Table of contents

Summary Table of Contentsp.3Table of Contentsp.4List of Figuresp.7List of Tablesp.8About this guidep.9Audiencep.9Structurep.9Precautionsp.10Safety when working with electricityp.11General observationsp.12Typographical conventions used in this documentp.12General conventionsp.12Chapter 1 General informationp.13SmartNode 4940 overviewp.14SN4940 model codesp.15SN4941 model codesp.15SmartNode 4940 rear panelp.16SmartNode 4940 front panelp.18Chapter 2 Applications overviewp.20Introductionp.21Application-Convert Legacy PBX to VoIPp.21Chapter 3 SmartNode installationp.22Planning the installationp.23Site logp.23Network informationp.23Network Diagramp.23IP related informationp.23Software toolsp.24AC Power Mainsp.24Location and mounting requirementsp.24Installing the gatewayp.24Placing the SmartNodep.24Installing cablesp.24Connecting the PRIp.25Connecting the 10/100/1000Base-T Ethernet cablep.25Connecting the power supplyp.26Chapter 4 Initial configurationp.27Introductionp.28Configuring the desired IP addressp.28Factory-default IP settingsp.28Connecting the SmartNode to the networkp.28Loading the configuration (optional)p.29Bootloaderp.30Start Bootloaderp.30Start-up with factory configurationp.30Load a new application image (SmartWare) via TFTPp.30Load a new application image (SmartWare) via the serial linkp.32Additional informationp.33Chapter 5 Contacting Patton for assistancep.34Introductionp.35Contact informationp.35Patton support headquarters in the USAp.35Alternate Patton support for Europe, Middle East, and Africa (EMEA)p.35Warranty Service and Returned Merchandise Authorizations (RMAs)p.35Warranty coveragep.35Out-of-warranty servicep.36Returns for creditp.36Return for credit policyp.36RMA numbersp.36Shipping instructionsp.36Appendix A Compliance informationp.37Compliancep.38EMCp.38Safetyp.38PSTN Regulatoryp.38Radio and TV Interferencep.38FCC Part 68 (ACTA) Statementp.39Industry Canada Noticep.39CE Declaration of Conformityp.40Authorized European Representativep.40Appendix B Specificationsp.41Voice connectivityp.42Data connectivityp.42Voice processing (signalling dependent)p.42Fax and modem supportp.42Voice signallingp.43Voice routing-session routerp.43IP servicesp.43Managementp.44Systemp.44Physicalp.44Identification of the SmartNode devices via SNMPp.45Appendix C Cablingp.47Introductionp.48Consolep.48Ethernetp.49E1 PRIp.50T1 PRIp.51Appendix D Port pin-outsp.52Introductionp.53Console portp.53Ethernetp.53PRI portp.54Appendix E SmartNode 4940 factory configurationp.55Introductionp.56Appendix F End user license agreementp.57End User License Agreementp.581. Definitionsp.582. Titlep.583. Termp.584. Grant of Licensep.585. Warrantyp.586. Terminationp.597. Other licensesp.59
Page 35 of the Patton electronic 49040 user manual — Warranty Service and Returned Merchandise Authorizations (RMAs)
Page 35 · click to enlarge
Page 35

SmartNode 4940 User Manual 5 • Contacting Patton for assistance

Introduction

This chapter contains the following information:

  • “Contact information” —describes how to contact Patton technical support for assistance.
  • “Warranty Service and Returned Merchandise Authorizations (RMAs)” —contains information about the warranty and obtaining a return merchandise authorization (RMA).

Contact information

Patton Electronics offers a wide array of free technical services. If you have questions about any of our other products we recommend you begin your search for answers by using our technical knowledge base. Here, we have gathered together many of the more commonly asked questions and compiled them into a searchable database to help you quickly solve your problems.

Patton support headquarters in the USA • Online support: available at www.patton.com

  • E-mail support: e-mail sent to support@<a href="http://patton.com" rel="nofollow noopener" target="_blank">patton.com</a> will be answered within 1 business day
  • Telephone support: standard telephone support is available five days a week—from 8:00 am to 5:00 pm EST ( 1300 to 2200 UTC/GMT )—by calling +1 (301) 975-1007
  • Fax: +1 (253) 663-5693

Alternate Patton support for Europe, Middle East, and Africa (EMEA) • Online support: available at www.patton-inalp.com

  • E-mail support: e-mail sent to support@<a href="http://patton-inalp.com" rel="nofollow noopener" target="_blank">patton-inalp.com</a> will be answered within 1 business day
  • Telephone support: standard telephone support is available five days a week—from 8:00 am to 5:00 pm CET ( 0900 to 1800 UTC/GMT )—by calling +41 (0)31 985 25 55
  • Fax: +41 (0)31 985 25 26

Warranty Service and Returned Merchandise Authorizations (RMAs)

Patton Electronics is an ISO-9001 certified manufacturer and our products are carefully tested before ship- ment. All of our products are backed by a comprehensive warranty program.

Warranty coverage Our products are under warranty to be free from defects, and we will, at our option, repair or replace the prod- uct should it fail within one year from the first date of shipment. Our warranty is limited to defects in work- manship or materials, and does not cover customer damage, lightning or power surge damage, abuse, or unauthorized modification.

Introduction 35

Page 36 of the Patton electronic 49040 user manual — Out-of-warranty service
Page 36 · click to enlarge
Page 36

SmartNode 4940 User Manual 5 • Contacting Patton for assistance

Out-of-warranty service Patton services what we sell, no matter how you acquired it, including malfunctioning products that are no longer under warranty. Our products have a flat fee for repairs. Units damaged by lightning or other catastro- phes may require replacement.

Returns for credit Customer satisfaction is important to us, therefore any product may be returned with authorization within 30 days from the shipment date for a full credit of the purchase price. If you have ordered the wrong equipment or you are dissatisfied in any way, please contact us to request an RMA number to accept your return. Patton is not responsible for equipment returned without a Return Authorization.

Return for credit policy • Less than 30 days: No Charge. Your credit will be issued upon receipt and inspection of the equipment.

  • 30 to 60 days: We will add a 20% restocking charge (crediting your account with 80% of the purchase price).
  • Over 60 days: Products will be accepted for repairs only.

RMA numbers RMA numbers are required for all product returns. You can obtain an RMA by doing one of the following:

  • Completing a request on the RMA Request page in the Support section at <a href="http://www.patton.com" rel="nofollow noopener" target="_blank">www.patton.com</a>
  • By calling +1 (301) 975-1007 and speaking to a Technical Support Engineer
  • By sending an e-mail to returns@<a href="http://patton.com" rel="nofollow noopener" target="_blank">patton.com</a>

All returned units must have the RMA number clearly visible on the outside of the shipping container. Please use the original packing material that the device came in or pack the unit securely to avoid damage during shipping.

Shipping instructions The RMA number should be clearly visible on the address label. Our shipping address is as follows:

Patton Electronics Company RMA#xxxx 7622 Rickenbacker Dr. Gaithersburg, MD 20879-4773 USA

Patton will ship the equipment back to you in the same manner you ship it to us. Patton will pay the return shipping costs.

Warranty Service and Returned Merchandise Authorizations (RMAs) 36

Page 37 of the Patton electronic 49040 user manual — Table of contents
Page 37 · click to enlarge
Page 37

Table of contents

Summary Table of Contentsp.3Table of Contentsp.4List of Figuresp.7List of Tablesp.8About this guidep.9Audiencep.9Structurep.9Precautionsp.10Safety when working with electricityp.11General observationsp.12Typographical conventions used in this documentp.12General conventionsp.12Chapter 1 General informationp.13SmartNode 4940 overviewp.14SN4940 model codesp.15SN4941 model codesp.15SmartNode 4940 rear panelp.16SmartNode 4940 front panelp.18Chapter 2 Applications overviewp.20Introductionp.21Application-Convert Legacy PBX to VoIPp.21Chapter 3 SmartNode installationp.22Planning the installationp.23Site logp.23Network informationp.23Network Diagramp.23IP related informationp.23Software toolsp.24AC Power Mainsp.24Location and mounting requirementsp.24Installing the gatewayp.24Placing the SmartNodep.24Installing cablesp.24Connecting the PRIp.25Connecting the 10/100/1000Base-T Ethernet cablep.25Connecting the power supplyp.26Chapter 4 Initial configurationp.27Introductionp.28Configuring the desired IP addressp.28Factory-default IP settingsp.28Connecting the SmartNode to the networkp.28Loading the configuration (optional)p.29Bootloaderp.30Start Bootloaderp.30Start-up with factory configurationp.30Load a new application image (SmartWare) via TFTPp.30Load a new application image (SmartWare) via the serial linkp.32Additional informationp.33Chapter 5 Contacting Patton for assistancep.34Introductionp.35Contact informationp.35Patton support headquarters in the USAp.35Alternate Patton support for Europe, Middle East, and Africa (EMEA)p.35Warranty Service and Returned Merchandise Authorizations (RMAs)p.35Warranty coveragep.35Out-of-warranty servicep.36Returns for creditp.36Return for credit policyp.36RMA numbersp.36Shipping instructionsp.36Appendix A Compliance informationp.37Compliancep.38EMCp.38Safetyp.38PSTN Regulatoryp.38Radio and TV Interferencep.38FCC Part 68 (ACTA) Statementp.39Industry Canada Noticep.39CE Declaration of Conformityp.40Authorized European Representativep.40Appendix B Specificationsp.41Voice connectivityp.42Data connectivityp.42Voice processing (signalling dependent)p.42Fax and modem supportp.42Voice signallingp.43Voice routing-session routerp.43IP servicesp.43Managementp.44Systemp.44Physicalp.44Identification of the SmartNode devices via SNMPp.45Appendix C Cablingp.47Introductionp.48Consolep.48Ethernetp.49E1 PRIp.50T1 PRIp.51Appendix D Port pin-outsp.52Introductionp.53Console portp.53Ethernetp.53PRI portp.54Appendix E SmartNode 4940 factory configurationp.55Introductionp.56Appendix F End user license agreementp.57End User License Agreementp.581. Definitionsp.582. Titlep.583. Termp.584. Grant of Licensep.585. Warrantyp.586. Terminationp.597. Other licensesp.59
Page 38 of the Patton electronic 49040 user manual — Radio and TV Interference
Page 38 · click to enlarge
Page 38

SmartNode 4940 User Manual A • Compliance information

Compliance

EMC • FCC Part 15, Class A

  • EN55022, Class A
  • EN55024

Safety • UL 60950-1/CSA C22.2 N0. 60950-1

  • IEC/EN60950-1
  • AS/NZS 60950-1

PSTN Regulatory • FCC Part 68

  • CS-03
  • TBR 4
  • AS/ACIF S016
  • AS/ACIF S038
  • NZ ISDN Layer 3 Supplement

Radio and TV Interference

The SmartNode router generates and uses radio frequency energy, and if not installed and used properly-that is, in strict accordance with the manufacturer’s instructions-may cause interference to radio and television reception. The SmartNode router have been tested and found to comply with the limits for a Class A comput- ing device in accordance with specifications in Subpart B of Part 15 of FCC rules, which are designed to pro- vide reasonable protection from such interference in a commercial installation. However, there is no guarantee that interference will not occur in a particular installation. If the SmartNode router does cause interference to radio or television reception, which can be determined by disconnecting the unit, the user is encouraged to try to correct the interference by one or more of the following measures: moving the computing equipment away from the receiver, re-orienting the receiving antenna and/or plugging the receiving equipment into a different AC outlet (such that the computing equipment and receiver are on different branches).

Compliance 38

Page 39 of the Patton electronic 49040 user manual — Industry Canada Notice
Page 39 · click to enlarge
Page 39

SmartNode 4940 User Manual A • Compliance information

FCC Part 68 (ACTA) Statement

This equipment complies with Part 68 of FCC rules and the requirements adopted by ACTA. On the bottom side of this equipment is a label that contains—among other information—a product identifier in the format US: AAAEQ##TXXXX. If requested, this number must be provided to the telephone company.

The method used to connect this equipment to the premises wiring and telephone network must comply with the applicable FCC Part 68 rules and requirements adopted by the ACTA.

If this equipment causes harm to the telephone network, the telephone company will notify you in advance that temporary discontinuance of service may be required. But if advance notice isn’t practical, the telephone company will notify the customer as soon as possible. Also, you will be advised of your right to file a complaint with the FCC if you believe it is necessary.

The telephone company may make changes in its facilities, equipment, operations or procedures that could affect the operation of the equipment. If this happens the telephone company will provide advance notice in order for you to make necessary modifications to maintain uninterrupted service.

If trouble is experienced with this equipment, for repair or warranty information, please contact our company. If the equipment is causing harm to the telephone network, the telephone company may request that you dis- connect the equipment until the problem is resolved.

Connection to party line service is subject to state tariffs. Contact the state public utility commission, public service commission or corporation commission for information.

Industry Canada Notice

This equipment meets the applicable Industry Canada Terminal Equipment Technical Specifications. This is confirmed by the registration number. The abbreviation, IC, before the registration number signifies that reg- istration was performed based on a Declaration of Conformity indicating that Industry Canada technical speci- fications were met. It does not imply that Industry Canada approved the equipment.

This Declaration of Conformity means that the equipment meets certain telecommunications network protec- tive, operational and safety requirements. The Department does not guarantee the equipment will operate to the user's satisfaction. Before installing this equipment, users should ensure that it is permissible to be con- nected to the facilities of the local telecommunications company. The equipment must also be installed using an acceptable method of connection. In some cases, the company’s inside wiring associated with a single line individual service may be extended by means of a certified connector assembly (telephone extension cord). The customer should be aware that compliance with the above condition may not prevent degradation of service in some situations. Repairs to some certified equipment should be made by an authorized maintenance facility designated by the supplier. Any repairs or alterations made by the user to this equipment, or equipment mal- functions, may give the telecommunications company cause to request the user to disconnect the equipment. Users should ensure for their own protection that the ground connections of the power utility, telephone lines and internal metallic water pipe system, are connected together. This protection may be particularly important in rural areas.

FCC Part 68 (ACTA) Statement 39

Page 40 of the Patton electronic 49040 user manual — Authorized European Representative
Page 40 · click to enlarge
Page 40

SmartNode 4940 User Manual A • Compliance information

CE Declaration of Conformity

This equipment conforms to the requirements of Council Directive 1999/5/EC on the approximation of the laws of the member states relating to Radio and Telecommunication Terminal Equipment and the mutual rec- ognition of their conformity.

The safety advice in the documentation accompanying this product shall be obeyed. The conformity to the above directive is indicated by CE sign on the device.

The signed Declaration of Conformity can be downloaded at www.patton.com/certifications

Authorized European Representative

D R M Green European Compliance Services Limited. Oakdene House, Oak Road Watchfield, Swindon, Wilts SN6 8TD, UK

CE Declaration of Conformity 40

Page 41 of the Patton electronic 49040 user manual — Table of contents
Page 41 · click to enlarge
Page 41

Table of contents

Summary Table of Contentsp.3Table of Contentsp.4List of Figuresp.7List of Tablesp.8About this guidep.9Audiencep.9Structurep.9Precautionsp.10Safety when working with electricityp.11General observationsp.12Typographical conventions used in this documentp.12General conventionsp.12Chapter 1 General informationp.13SmartNode 4940 overviewp.14SN4940 model codesp.15SN4941 model codesp.15SmartNode 4940 rear panelp.16SmartNode 4940 front panelp.18Chapter 2 Applications overviewp.20Introductionp.21Application-Convert Legacy PBX to VoIPp.21Chapter 3 SmartNode installationp.22Planning the installationp.23Site logp.23Network informationp.23Network Diagramp.23IP related informationp.23Software toolsp.24AC Power Mainsp.24Location and mounting requirementsp.24Installing the gatewayp.24Placing the SmartNodep.24Installing cablesp.24Connecting the PRIp.25Connecting the 10/100/1000Base-T Ethernet cablep.25Connecting the power supplyp.26Chapter 4 Initial configurationp.27Introductionp.28Configuring the desired IP addressp.28Factory-default IP settingsp.28Connecting the SmartNode to the networkp.28Loading the configuration (optional)p.29Bootloaderp.30Start Bootloaderp.30Start-up with factory configurationp.30Load a new application image (SmartWare) via TFTPp.30Load a new application image (SmartWare) via the serial linkp.32Additional informationp.33Chapter 5 Contacting Patton for assistancep.34Introductionp.35Contact informationp.35Patton support headquarters in the USAp.35Alternate Patton support for Europe, Middle East, and Africa (EMEA)p.35Warranty Service and Returned Merchandise Authorizations (RMAs)p.35Warranty coveragep.35Out-of-warranty servicep.36Returns for creditp.36Return for credit policyp.36RMA numbersp.36Shipping instructionsp.36Appendix A Compliance informationp.37Compliancep.38EMCp.38Safetyp.38PSTN Regulatoryp.38Radio and TV Interferencep.38FCC Part 68 (ACTA) Statementp.39Industry Canada Noticep.39CE Declaration of Conformityp.40Authorized European Representativep.40Appendix B Specificationsp.41Voice connectivityp.42Data connectivityp.42Voice processing (signalling dependent)p.42Fax and modem supportp.42Voice signallingp.43Voice routing-session routerp.43IP servicesp.43Managementp.44Systemp.44Physicalp.44Identification of the SmartNode devices via SNMPp.45Appendix C Cablingp.47Introductionp.48Consolep.48Ethernetp.49E1 PRIp.50T1 PRIp.51Appendix D Port pin-outsp.52Introductionp.53Console portp.53Ethernetp.53PRI portp.54Appendix E SmartNode 4940 factory configurationp.55Introductionp.56Appendix F End user license agreementp.57End User License Agreementp.581. Definitionsp.582. Titlep.583. Termp.584. Grant of Licensep.585. Warrantyp.586. Terminationp.597. Other licensesp.59
Page 42 of the Patton electronic 49040 user manual — RTP/RTCP (RFC 1889)
Page 42 · click to enlarge
Page 42

SmartNode 4940 User Manual B • Specifications

Voice connectivity

1 or 4 PRI T1/E1 ports on RJ48C connectors

Net/User configurable per port

Each port can be slave or master clock

Each port can be used to synchronize to an external clock master

Failover relay between ports 0/0 and 0/1 for specific models

Data connectivity

One 10/100/1000Base-Tx Gigabit Ethernet port

All ports full duplex, autosensing, auto-MDX

Voice processing (signalling dependent)

Four or eight full-duplex channels with Voice CODECS:

  • G.711 A-Law/ -Law (64 kbps)
  • G.726 (ADPCM 16, 24, 32, 40 kbps)
  • G.723.1 (5.3 or 6.3 kbps)
  • G.729ab (8 kbps)
  • Transparent ISDN data

G.168 echo cancellation (128 ms)

Up to 120 simultaneous voice or T.38 fax calls

DTMF detection and generation

Carrier tone detection and generation

Silence suppression and comfort noise

Adaptive and configurable dejitter buffer

Configurable tones (dial, ringing, busy)

Configurable transmit packet length

RTP/RTCP (RFC 1889)

Fax and modem support

Automatic fax and modem detection

Codec fallback for modem-bypass

T.38 Fax-Relay (Gr. 3 Fax, 9.6 k, 14.4 k)

Voice connectivity 42

Page 43 of the Patton electronic 49040 user manual — IP services
Page 43 · click to enlarge
Page 43

SmartNode 4940 User Manual B • Specifications

G.711 Fax-Bypass

Voice signalling

H.323v4

SIP call transfer, redirect

Overlap or en-bloc dialing

Voice routing—session router

Call Routing Criteria:

  • Interface
  • Calling/called party number
  • Time of day, day of week, date
  • ISDN bearer capability
  • Various other information elements (IEs) of the ISDN setup
  • Wildcard and regular expression matching

Regular expression number manipulation functions:

  • Replace numbers
  • Add/remove digits
  • Pattern matching and replacement

IP services

DiffServe/ToS set per header bits

802.1p VLAN tagging

IPSEC AH & ESP Modes

Show 11 more labels / short text on this page
SIPv2 · DTMF in-band, out-of-band · Configurable progress tones · Local switching (hairpinning) · Least cost routing · Interface huntgroups · Call-Distribution groups · Number blocking · Manual Key; IKE · AES/DES/3DES Encryption · Voice signalling 43
Page 44 of the Patton electronic 49040 user manual — Physical
Page 44 · click to enlarge
Page 44

SmartNode 4940 User Manual B • Specifications

Management

Industry standard CLI with local console (RJ-45, RJ-231, 9600 bps, 8, N, 1) and remote Telnet access, fully documented

HTTP web management and firmware loading

TFTP configuration & firmware loading

SNMP v1 agent (MIB II and private MIB)

Built-in diagnostic tools (trace, debug)

System

CPU Motorola MPC8360 series operating at 266/400 MHz

Memory:

  • 128 Mbytes RAM (DDR, 266MHz)
  • 8 Mbytes Flash

Physical

Dimensions11.9W x 1.71H x 7.16D inch (302W x 44H x 182mm)
Weight<21 oz. (<600g)
Power Consumption< 16W
Operating temperature32–104°F (0–40°C)
Operating humidityup to 90%, non condensing

Web-based GUI · Secure Auto-provisioning · Management 44

Page 45 of the Patton electronic 49040 user manual — Identification of the SmartNode devices via SNMP
Page 45 · click to enlarge
Page 45

SmartNode 4940 User Manual B • Specifications

Identification of the SmartNode devices via SNMP

All SmartNode devices have assigned sysObjectID (.iso.org.dod.internet.mgmt.mib-2.system.sysObjectID) numbers (see table 7).

Table 7. SmartNode Models and their Unique sysObjectID

SN4940/1E15V .iso.org.dod.internet.private.enterprises.patton.products.sn49xx.1 1.3.6.1.4.1.1768.100.4.16.1

SN4940/1E24V .iso.org.dod.internet.private.enterprises.patton.products.sn49xx.2 1.3.6.1.4.1.1768.100.4.16.2

SN4940/1E30V .iso.org.dod.internet.private.enterprises.patton.products.sn49xx.3 1.3.6.1.4.1.1768.100.4.16.3

SN4940/4E15V .iso.org.dod.internet.private.enterprises.patton.products.sn49xx.4 1.3.6.1.4.1.1768.100.4.16.4

SN4940/4E24V .iso.org.dod.internet.private.enterprises.patton.products.sn49xx.5 1.3.6.1.4.1.1768.100.4.16.5

SN4940/4E30V .iso.org.dod.internet.private.enterprises.patton.products.sn49xx.6 1.3.6.1.4.1.1768.100.4.16.6

SN4940/4E48V .iso.org.dod.internet.private.enterprises.patton.products.sn49xx.7 1.3.6.1.4.1.1768.100.4.16.7

SN4940/4E60V .iso.org.dod.internet.private.enterprises.patton.products.sn49xx.8 1.3.6.1.4.1.1768.100.4.16.8

SN4940/4E96V .iso.org.dod.internet.private.enterprises.patton.products.sn49xx.9 1.3.6.1.4.1.1768.100.4.16.9

SN4940/4E120V .iso.org.dod.internet.private.enterprises.patton.products.sn49xx.10 1.3.6.1.4.1.1768.100.4.16.10

SN4951/1E15V .iso.org.dod.internet.private.enterprises.patton.products.sn49xx.11 1.3.6.1.4.1.1768.100.4.16.11

SN4951/1E24V .iso.org.dod.internet.private.enterprises.patton.products.sn49xx.12 1.3.6.1.4.1.1768.100.4.16.12

SN4951/1E30V .iso.org.dod.internet.private.enterprises.patton.products.sn49xx.13 1.3.6.1.4.1.1768.100.4.16.13

SN4951/4E15V .iso.org.dod.internet.private.enterprises.patton.products.sn49xx.14 1.3.6.1.4.1.1768.100.4.16.14

SN4951/4E24V .iso.org.dod.internet.private.enterprises.patton.products.sn49xx.15 1.3.6.1.4.1.1768.100.4.16.15

SN4951/4E30V .iso.org.dod.internet.private.enterprises.patton.products.sn49xx.16 1.3.6.1.4.1.1768.100.4.16.16

SN4951/4E48V .iso.org.dod.internet.private.enterprises.patton.products.sn49xx.17 1.3.6.1.4.1.1768.100.4.16.17

SN4951/4E60V .iso.org.dod.internet.private.enterprises.patton.products.sn49xx.18 1.3.6.1.4.1.1768.100.4.16.18

SN4951/4E96V .iso.org.dod.internet.private.enterprises.patton.products.sn49xx.19 1.3.6.1.4.1.1768.100.4.16.19

Identification of the SmartNode devices via SNMP 45

SmartNode Model SysObjectID

Page 46 of the Patton electronic 49040 user manual — IMPORTANT
Page 46 · click to enlarge
Page 46

SmartNode 4940 User Manual B • Specifications

Table 7. SmartNode Models and their Unique sysObjectID (Continued)

SN4941/4E120V .iso.org.dod.internet.private.enterprises.patton.products.sn49xx.20 1.3.6.1.4.1.1768.100.4.16.20

According to table 7, an SNMP get request to .iso.org.dod.internet.mgmt.mib-2.system.sysObjectID of a Smart- Node 4940/1E15V/EUI device reads out a numeric OID of 1.3.6.1.4.1.1768.100.4.16.1, which represents a SmartNode 4940/1E15V/EUI device. The mapping of the sysObjectID to each of the SmartNode model is realized with the SmartNode product identification MIB.

The SNMP agent running in SmartWare is SNMP version 1 (SNMPv1) compliant. SNMP version 2 (SNMPv2) and SNMP version 3 (SNMPv3) are not currently supported.

IMPORTANT

Identification of the SmartNode devices via SNMP 46

SmartNode Model SysObjectID

Page 47 of the Patton electronic 49040 user manual — Table of contents
Page 47 · click to enlarge
Page 47

Table of contents

Summary Table of Contentsp.3Table of Contentsp.4List of Figuresp.7List of Tablesp.8About this guidep.9Audiencep.9Structurep.9Precautionsp.10Safety when working with electricityp.11General observationsp.12Typographical conventions used in this documentp.12General conventionsp.12Chapter 1 General informationp.13SmartNode 4940 overviewp.14SN4940 model codesp.15SN4941 model codesp.15SmartNode 4940 rear panelp.16SmartNode 4940 front panelp.18Chapter 2 Applications overviewp.20Introductionp.21Application-Convert Legacy PBX to VoIPp.21Chapter 3 SmartNode installationp.22Planning the installationp.23Site logp.23Network informationp.23Network Diagramp.23IP related informationp.23Software toolsp.24AC Power Mainsp.24Location and mounting requirementsp.24Installing the gatewayp.24Placing the SmartNodep.24Installing cablesp.24Connecting the PRIp.25Connecting the 10/100/1000Base-T Ethernet cablep.25Connecting the power supplyp.26Chapter 4 Initial configurationp.27Introductionp.28Configuring the desired IP addressp.28Factory-default IP settingsp.28Connecting the SmartNode to the networkp.28Loading the configuration (optional)p.29Bootloaderp.30Start Bootloaderp.30Start-up with factory configurationp.30Load a new application image (SmartWare) via TFTPp.30Load a new application image (SmartWare) via the serial linkp.32Additional informationp.33Chapter 5 Contacting Patton for assistancep.34Introductionp.35Contact informationp.35Patton support headquarters in the USAp.35Alternate Patton support for Europe, Middle East, and Africa (EMEA)p.35Warranty Service and Returned Merchandise Authorizations (RMAs)p.35Warranty coveragep.35Out-of-warranty servicep.36Returns for creditp.36Return for credit policyp.36RMA numbersp.36Shipping instructionsp.36Appendix A Compliance informationp.37Compliancep.38EMCp.38Safetyp.38PSTN Regulatoryp.38Radio and TV Interferencep.38FCC Part 68 (ACTA) Statementp.39Industry Canada Noticep.39CE Declaration of Conformityp.40Authorized European Representativep.40Appendix B Specificationsp.41Voice connectivityp.42Data connectivityp.42Voice processing (signalling dependent)p.42Fax and modem supportp.42Voice signallingp.43Voice routing-session routerp.43IP servicesp.43Managementp.44Systemp.44Physicalp.44Identification of the SmartNode devices via SNMPp.45Appendix C Cablingp.47Introductionp.48Consolep.48Ethernetp.49E1 PRIp.50T1 PRIp.51Appendix D Port pin-outsp.52Introductionp.53Console portp.53Ethernetp.53PRI portp.54Appendix E SmartNode 4940 factory configurationp.55Introductionp.56Appendix F End user license agreementp.57End User License Agreementp.581. Definitionsp.582. Titlep.583. Termp.584. Grant of Licensep.585. Warrantyp.586. Terminationp.597. Other licensesp.59
Page 48 of the Patton electronic 49040 user manual — Console
Page 48 · click to enlarge
Page 48

SmartNode 4940 User Manual C • Cabling

Introduction

This section provides information on the cables used to connect the SmartNode and the interface cards to the existing network infrastructure and to third party products.

Console

The SmartNode can be connected to a serial terminal over its serial console port, as depicted in figure 7.

Patton electronic 49040 — Console diagram (page 48)
Fig. 8 · Console

The interconnecting cables shall be acceptable for external use and shall be rated for the proper application with respect to volt- age, current, anticipated temperature, flammability, and mechanical serviceability. CAUTION

Patton electronic 49040 — Console diagram (page 48)
Fig. 9 · Console

Figure 7. Connecting a serial terminal

Introduction 48

Page 49 of the Patton electronic 49040 user manual — Ethernet
Page 49 · click to enlarge
Page 49

SmartNode 4940 User Manual C • Cabling

Ethernet

Ethernet devices (10Base-T/100Base-T/1000Base-T) are connected to the SmartNode over a cable with RJ-45 plugs. The Ethernet port on the SN4940 is Auto-MDX and uses any straight or crossover cable to connect to hubs, switches, PCs or other devices.

Patton electronic 49040 — Ethernet diagram (page 49)
Fig. 10 · Ethernet

The interconnecting cables shall be acceptable for external use and shall be rated for the proper application with respect to volt- age, current, anticipated temperature, flammability, and mechanical serviceability. CAUTION

Patton electronic 49040 — Ethernet diagram (page 49)
Fig. 11 · Ethernet

Figure 8. Typical Ethernet straight-through cable diagram for 10/100Base-T

Patton electronic 49040 — Ethernet diagram (page 49)
Fig. 12 · Ethernet

Figure 9. Typical Ethernet straight-through cable diagram for 1000Base-T

Ethernet 49

Page 50 of the Patton electronic 49040 user manual — E1 PRI 50
Page 50 · click to enlarge
Page 50

SmartNode 4940 User Manual C • Cabling

E1 PRI

The E1 PRI is usually connected to a PBX or switch—local exchange (LE). Type and pin outs of these devices vary depending on the manufacturer. In most cases, a straight-through RJ-45 to RJ-45 can be used to connect the PRI with a PBX. A cross-over cable is required to connect to an NT device, as illustrated in figure 10 on page 50.

Patton electronic 49040 — E1 PRI diagram (page 50)
Fig. 13

Hazardous network voltages are present in the PRI cables. If you detach the cable, detach the end away from the SmartNode or interface card first to avoid possible electric shock. Network hazardous voltages may be present on the device in the area of the PRI port, regardless of when power is turned OFF.

To prevent damage to the system, make certain you connect the PRI cable to the PRI port only and not to any other RJ-45 socket.

Patton electronic 49040 — E1 PRI diagram (page 50)
Fig. 14

Figure 10. Connecting an E1 PRI port to an NT1

Patton electronic 49040 — E1 PRI diagram (page 50)
Fig. 15

Figure 11. E1 PRI port crossover cable

E1 PRI 50

Page 51 of the Patton electronic 49040 user manual — T1 PRI 51
Page 51 · click to enlarge
Page 51

SmartNode 4940 User Manual C • Cabling

T1 PRI

The T1 PRI is usually connected to a PBX or switch—local exchange (LE). Type and pin outs of these devices vary depending on the manufacturer. In most cases, a straight-through RJ-45 to RJ-45 can be used to connect the PRI with a PBX. A cross-over cable is required to connect to an NT device, as illustrated in figure 12 on page 51.

Patton electronic 49040 — T1 PRI diagram (page 51)
Fig. 16

Hazardous network voltages are present in the PRI cables. If you detach the cable, detach the end away from the SmartNode or interface card first to avoid possible electric shock. Network hazardous voltages may be present on the device in the area of the PRI port, regardless of when power is turned OFF.

To prevent damage to the system, make certain you connect the PRI cable to the PRI port only and not to any other RJ-45 socket.

Figure 12. Connecting a T1 PRI port to an NT device

Patton electronic 49040 — T1 PRI diagram (page 51)
Fig. 17

Figure 13. T1 PRI crossover cable

T1 PRI 51

Page 52 of the Patton electronic 49040 user manual — Table of contents
Page 52 · click to enlarge
Page 52

Table of contents

Summary Table of Contentsp.3Table of Contentsp.4List of Figuresp.7List of Tablesp.8About this guidep.9Audiencep.9Structurep.9Precautionsp.10Safety when working with electricityp.11General observationsp.12Typographical conventions used in this documentp.12General conventionsp.12Chapter 1 General informationp.13SmartNode 4940 overviewp.14SN4940 model codesp.15SN4941 model codesp.15SmartNode 4940 rear panelp.16SmartNode 4940 front panelp.18Chapter 2 Applications overviewp.20Introductionp.21Application-Convert Legacy PBX to VoIPp.21Chapter 3 SmartNode installationp.22Planning the installationp.23Site logp.23Network informationp.23Network Diagramp.23IP related informationp.23Software toolsp.24AC Power Mainsp.24Location and mounting requirementsp.24Installing the gatewayp.24Placing the SmartNodep.24Installing cablesp.24Connecting the PRIp.25Connecting the 10/100/1000Base-T Ethernet cablep.25Connecting the power supplyp.26Chapter 4 Initial configurationp.27Introductionp.28Configuring the desired IP addressp.28Factory-default IP settingsp.28Connecting the SmartNode to the networkp.28Loading the configuration (optional)p.29Bootloaderp.30Start Bootloaderp.30Start-up with factory configurationp.30Load a new application image (SmartWare) via TFTPp.30Load a new application image (SmartWare) via the serial linkp.32Additional informationp.33Chapter 5 Contacting Patton for assistancep.34Introductionp.35Contact informationp.35Patton support headquarters in the USAp.35Alternate Patton support for Europe, Middle East, and Africa (EMEA)p.35Warranty Service and Returned Merchandise Authorizations (RMAs)p.35Warranty coveragep.35Out-of-warranty servicep.36Returns for creditp.36Return for credit policyp.36RMA numbersp.36Shipping instructionsp.36Appendix A Compliance informationp.37Compliancep.38EMCp.38Safetyp.38PSTN Regulatoryp.38Radio and TV Interferencep.38FCC Part 68 (ACTA) Statementp.39Industry Canada Noticep.39CE Declaration of Conformityp.40Authorized European Representativep.40Appendix B Specificationsp.41Voice connectivityp.42Data connectivityp.42Voice processing (signalling dependent)p.42Fax and modem supportp.42Voice signallingp.43Voice routing-session routerp.43IP servicesp.43Managementp.44Systemp.44Physicalp.44Identification of the SmartNode devices via SNMPp.45Appendix C Cablingp.47Introductionp.48Consolep.48Ethernetp.49E1 PRIp.50T1 PRIp.51Appendix D Port pin-outsp.52Introductionp.53Console portp.53Ethernetp.53PRI portp.54Appendix E SmartNode 4940 factory configurationp.55Introductionp.56Appendix F End user license agreementp.57End User License Agreementp.581. Definitionsp.582. Titlep.583. Termp.584. Grant of Licensep.585. Warrantyp.586. Terminationp.597. Other licensesp.59
Page 53 of the Patton electronic 49040 user manual — 1 TX+
Page 53 · click to enlarge
Page 53

SmartNode 4940 User Manual D • Port pin-outs

Introduction

This section provides pin-out information for the ports of the SmartNode.

Console port

Configuration settings9600 bps, 8 bits, no parity, 1 stop bit, no flow control

8–RTS (N/C) 7–CTS (N/C) 6–TD 5–RD 4–SG 3–DTR 2–CD (N/C) 1–DSR

1 2 3 4 5 6 7 8

Pins 1 & 3 are connected together

Figure 14. EIA-561 (RJ-45 8-pin) port

Ethernet

Table 8. RJ45 socket 10/100Base-T

1 TX+

2 TX-

3 RX+

6 RX-

Pin Signal · Introduction 53

Page 54 of the Patton electronic 49040 user manual — 1 TRD0+
Page 54 · click to enlarge
Page 54

SmartNode 4940 User Manual D • Port pin-outs

Table 9. RJ45 socket 1000Base-T

1 TRD0+

2 TRD0-

3 TRD1+

6 TRD1-

4 TRD2+

5 TRD2-

7 TRD3+

8 TRD3-

PRI port

Table 10. RJ-45 socket

Show 9 more labels / short text on this page
Pin Signal · Pin USR · 1 RX Ring · 2 RX Tip · 3 RX Shield · 4 TX Ring · 5 TX Tip · 6 TX Shield · PRI port 54
Page 55 of the Patton electronic 49040 user manual — Chapter contents
Page 55 · click to enlarge
Page 55

Appendix E SmartNode 4940 factory

configuration

Chapter contents

Introduction 56

Page 56 of the Patton electronic 49040 user manual — Introduction
Page 56 · click to enlarge
Page 56

SmartNode 4940 User Manual E • SmartNode 4940 factory configuration

Introduction

The factory configuration settings for SmartNode 4940 are as follows:

# 4940 Series # # Factory configuration file # sntp-client sntp-client server primary 129.132.2.21 port 123 version 4 system ic voice 0 low-bitrate-codec g729 context ip router interface eth0 ipadress dhcp tcp adjust-mss rx mtu tcp adjust-mss tx mtu port ethernet 0 0 medium auto encapsulation ip bimd interface eth0 router no shutdown

Introduction 56

Page 57 of the Patton electronic 49040 user manual — Table of contents
Page 57 · click to enlarge
Page 57

Table of contents

Summary Table of Contentsp.3Table of Contentsp.4List of Figuresp.7List of Tablesp.8About this guidep.9Audiencep.9Structurep.9Precautionsp.10Safety when working with electricityp.11General observationsp.12Typographical conventions used in this documentp.12General conventionsp.12Chapter 1 General informationp.13SmartNode 4940 overviewp.14SN4940 model codesp.15SN4941 model codesp.15SmartNode 4940 rear panelp.16SmartNode 4940 front panelp.18Chapter 2 Applications overviewp.20Introductionp.21Application-Convert Legacy PBX to VoIPp.21Chapter 3 SmartNode installationp.22Planning the installationp.23Site logp.23Network informationp.23Network Diagramp.23IP related informationp.23Software toolsp.24AC Power Mainsp.24Location and mounting requirementsp.24Installing the gatewayp.24Placing the SmartNodep.24Installing cablesp.24Connecting the PRIp.25Connecting the 10/100/1000Base-T Ethernet cablep.25Connecting the power supplyp.26Chapter 4 Initial configurationp.27Introductionp.28Configuring the desired IP addressp.28Factory-default IP settingsp.28Connecting the SmartNode to the networkp.28Loading the configuration (optional)p.29Bootloaderp.30Start Bootloaderp.30Start-up with factory configurationp.30Load a new application image (SmartWare) via TFTPp.30Load a new application image (SmartWare) via the serial linkp.32Additional informationp.33Chapter 5 Contacting Patton for assistancep.34Introductionp.35Contact informationp.35Patton support headquarters in the USAp.35Alternate Patton support for Europe, Middle East, and Africa (EMEA)p.35Warranty Service and Returned Merchandise Authorizations (RMAs)p.35Warranty coveragep.35Out-of-warranty servicep.36Returns for creditp.36Return for credit policyp.36RMA numbersp.36Shipping instructionsp.36Appendix A Compliance informationp.37Compliancep.38EMCp.38Safetyp.38PSTN Regulatoryp.38Radio and TV Interferencep.38FCC Part 68 (ACTA) Statementp.39Industry Canada Noticep.39CE Declaration of Conformityp.40Authorized European Representativep.40Appendix B Specificationsp.41Voice connectivityp.42Data connectivityp.42Voice processing (signalling dependent)p.42Fax and modem supportp.42Voice signallingp.43Voice routing-session routerp.43IP servicesp.43Managementp.44Systemp.44Physicalp.44Identification of the SmartNode devices via SNMPp.45Appendix C Cablingp.47Introductionp.48Consolep.48Ethernetp.49E1 PRIp.50T1 PRIp.51Appendix D Port pin-outsp.52Introductionp.53Console portp.53Ethernetp.53PRI portp.54Appendix E SmartNode 4940 factory configurationp.55Introductionp.56Appendix F End user license agreementp.57End User License Agreementp.581. Definitionsp.582. Titlep.583. Termp.584. Grant of Licensep.585. Warrantyp.586. Terminationp.597. Other licensesp.59
Page 58 of the Patton electronic 49040 user manual — End User License Agreement
Page 58 · click to enlarge
Page 58

SmartNode 4940 User Manual F • End user license agreement

End User License Agreement

By opening this package, operating the Designated Equipment or downloading the Program(s) electronically, the End User agrees to the following conditions:

1. Definitions A) Effective Date shall mean the earliest date of purchase or download of a product containing the Patton Electronics Company Program(s) or the Program(s) themselves.

B) Program(s) shall mean all software, software documentation, source code, object code, or executable code.

C) End User shall mean the person or organization which has valid title to the Designated Equipment.

D) Designated Equipment shall mean the hardware on which the Program(s) have been designed and pro- vided to operate by Patton Electronics Company.

2. Title Title to the Program(s), all copies of the Program(s), all patent rights, copyrights, trade secrets and proprietary information in the Program(s), worldwide, remains with Patton Electronics Company or its licensors.
3. Term The term of this Agreement is from the Effective Date until title of the Designated Equipment is transferred by End User or unless the license is terminated earlier as defined in section “6. Termination” on page 59.
4. Grant of License A) During the term of this Agreement, Patton Electronics Company grants a personal, non-transferable, non-assignable and non-exclusive license to the End User to use the Program(s) only with the Designated Equipment at a site owned or leased by the End User.

B) The End User may copy licensed Program(s) as necessary for backup purposes only for use with the Des- ignated Equipment that was first purchased or used or its temporary or permanent replacement.

C) The End User is prohibited from disassembling; decompiling, reverse-engineering or otherwise attempt- ing to discover or disclose the Program(s), source code, methods or concepts embodied in the Program(s) or having the same done by another party.

D) Should End User transfer title of the Designated Equipment to a third party after entering into this license agreement, End User is obligated to inform the third party in writing that a separate End User License Agreement from Patton Electronics Company is required to operate the Designated Equipment.

5. Warranty The Program(s) are provided as is without warranty of any kind. Patton Electronics Company and its licensors disclaim all warranties, either express or implied, including but not limited to the implied warranties of mer- chantability, fitness for a particular purpose or non-infringement. In no event shall Patton Electronics Com- pany or its licensors be liable for any damages whatsoever (including, without limitation, damages for loss of business profits, business interruption, loss of business information, or other pecuniary loss) arising out of the use of or inability to use the Program(s), even if Patton Electronics Company has been advised of the possibil- ity of such damages. Because some states do not allow the exclusion or limitation of liability for consequential or incidental damages, the above limitation may not apply to you.

End User License Agreement 58

Page 59 of the Patton electronic 49040 user manual — 6. Termination
Page 59 · click to enlarge
Page 59

SmartNode 4940 User Manual F • End user license agreement

If the Program(s) are acquired by or on behalf of a unit or agency of the United States Government, the Gov- ernment agrees that such Program(s) are commercial computer software or computer software documentation and that, absent a written agreement to the contrary, the Government’s rights with respect to such Program(s) are limited by the terms of this Agreement, pursuant to Federal Acquisition Regulations 12.212(a) and/or DEARS 227.7202-1(a) and/or sub-paragraphs (a) through (d) of the “Commercial Computer Software - Restricted Rights” clause at 48 C.F.R. 52.227-19 of the Federal Acquisition Regulations as applicable.

6. Termination A) The End User may terminate this agreement by returning the Designated Equipment and destroying all copies of the licensed Program(s).

B) Patton Electronics Company may terminate this Agreement should End User violate any of the provi- sions of section “4. Grant of License” on page 58.

C) Upon termination for A or B above or the end of the Term, End User is required to destroy all copies of the licensed Program(s)

7. Other licenses The Program may be subject to licenses extended by third parties. Accordingly, Patton Electronics Company licenses the Programs subject to the terms and conditions dictated by third parties. Third party software identified to the Programs includes:
  • A routing license is included at no charge.
  • MGCP capabilities will require the purchase of an additional license.
  • The LGPL (Lesser General Public License) open source license distributed to you pursuant to the LGPL license terms ( <a href="http://www.gnu.org/licenses/lgpl.html" rel="nofollow noopener" target="_blank">http://www.gnu.org/licenses/lgpl.html</a>).
  • RedBoot (Red Hat Embedded Debug and Bootstrap) embedded system debug/bootstrap environment from Red Hat distributed to you pursuant to the eCos license terms ( <a href="http://ecos.sourceware.org/licenseoverview.html" rel="nofollow noopener" target="_blank">http://ecos.sourceware.org/licenseoverview.html</a> ) and GNU General Public License (GPL) terms ( <a href="http://www.gnu.org/copyleft/gpl.html" rel="nofollow noopener" target="_blank">http://www.gnu.org/copyleft/gpl.html</a> ). Source code is available upon request.

End User License Agreement 59

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Patton electronic 49040

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Patton electronic 49040

Be the first to ask — other owners or our team will answer.

Original document

Patton electronic 49040 manual PDF

59 pages·860 KB·Universal Remote·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…