Page 1 of the Patton electronic 1006 user manual — USER MANUAL
Page 1 · click to enlarge
Page 1

USER MANUAL

MODEL 1006 DB-9 Async. Short Range Modem with Carrier Sense

Patton electronic 1006 — USER MANUAL diagram (page 1)
Fig. 1

Part #07M1006-C Doc. #060011UC Revised 4/29/98

SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 http://www.patton.com

An ISO-9001 Certified Company

Page 2 of the Patton electronic 1006 user manual — 1.2 CE NOTICE
Page 2 · click to enlarge
Page 2

1.0 WARRANTY INFORMATION

1.3 SERVICE

Patton Electronics warrants all Model 1006 components to be free from defects, and will—at our option—repair or replace the product should it fail within one year from the first date of shipment.

All warranty and non-warranty repairs must be returned freight prepaid and insured to Patton Electronics. All returns must have a Return Materials Authorization number on the outside of the shipping container. This number may be obtained from Patton Electronics Technical Service at

This warranty is limited to defects in workmanship or materials, and does not cover customer damage, abuse or unauthorized modification. If this product fails or does not perform as warranted, your sole recourse shall be repair or replacement as described above. Under no condition shall Patton Electronics be liable for any damages incurred by the use of this product. These damages include, but are not limited to, the following: lost profits, lost savings and incidental or consequential damages arising from the use of or inability to use this product. Patton Electronics specifically disclaims all other warranties, expressed or implied, and the installation or use of this product shall be deemed an acceptance of these terms by the user.

telephone: (301) 975-1007, web address: http://www.patton.com email: support@patton.com.

Patton Electronics’ technical staff is also available to answer any questions that might arise concerning the installation or use of your Model 1006. Technical Service hours: 8AM to 5PM EST, Monday through Friday.

1.1 RADIO AND TV INTERFERENCE

The Model 1006 generates and uses radio frequency energy, and if not installed and used properly—that is, in strict accordance with the manufacturer's instructions—may cause interference to radio and television reception. The Model 1006 has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in Subpart J of Part 15 of FCC rules, which are designed to provide reasonable protection from such interference in a commercial installation. However, there is no guarantee that interference will not occur in a particular installation. If the Model 1006 does cause interference to radio or television reception, which can be determined by turning the power off or removing the card, the user is encouraged to try to correct the interference by one or more of the following measures: moving the computing equipment away from the receiver, re-orienting the receiving antenna and/or plugging the receiving equipment into a different AC outlet (such that the computing equipment and receiver are on different branches).

1.2 CE NOTICE

The CE symbol on your Patton Electronics equipment indicates that it is in compliance with the Electromagnetic Compatibility (EMC) directive and the Low Voltage Directive (LVD) of the Union European (EU). A Certificate of Compliance is available by contacting Patton Technical Support.

Page 3 of the Patton electronic 1006 user manual — 2.2 DESCRIPTION
Page 3 · click to enlarge
Page 3

2.0 GENERAL INFORMATION

3.0 INSTALLATION

Thank you for your purchase of this Patton Electronics product. This product has been thoroughly inspected and tested and is warranted for One Year parts and labor. If any questions or problems arise during installation or use of this product, please do not hesitate to contact Patton Electronics Technical Support at (301) 975-1007.

The Model 1006 is easy to install. This section tells you how to properly connect the Model 1006 to the twisted pair and RS-232 interfaces, and how to operate the Model 1006.

3.1 CONNECTION TO THE TWISTED PAIR INTERFACE

2.1 FEATURES

The Model 1006 supports carrier sense handshaking between two DB-9 RS-232 devices at distances to 17 miles (27.2 km) and data rates to 19.2 Kbps. There are two requirements for installing the Model 1006:

  • Ideal for UNIX operating systems
  • Range to 17 miles (27.2 km)
  • Data rates to 19,200 bps
  • No AC power or batteries required
1. These units work in pairs. Therefore, you must have one Model 1006 at each end of a two twisted pair interface.
  • Carrier sense handshaking
  • Useful for troubleshooting or monitoring a line
2. To function properly, the Model 1006 needs two twisted pairs of metallic wire. The pairs must be unconditioned, dry metallic wire, between 19 and 26 AWG (the higher number gauges may limit distance). Standard dial-up telephone circuits, or leased circuits that run through signal equalization equipment are not acceptable.
  • Very thin case for closely spaced computer ports
  • Available with RJ-11, RJ-45 or terminal block with strain relief
  • Connects directly to the RS-232 port via DB-9 connector
  • Surge protection (Model 1006S only)
  • Made in USA

For your convenience, the Model 1006 is available with three different twisted pair interfaces: RJ-11 jack, RJ-45 jack and terminal blocks with strain relief.

2.2 DESCRIPTION

3.1.1 TWISTED PAIR CONNECTION USING RJ-11 OR RJ-45

The Patton Model 1006 Carrier Sense Short Range Modem allows RS-232 UNIX systems to communicate up to 17 miles (27.2 km) over two unconditioned twisted pair cable. Supporting data rates to 19.2 Kbps, the Model 1006 requires no AC power or batteries.

The RJ-11 and RJ-45 connectors on the Model 1006's twisted pair interface are pre-wired for a standard TELCO wiring environment (see Figure 1). The tables on the following page show the signal/pin relationships:

The Model 1006 has a special carrier sense feature, which automatically detects the presence of a carrier on the line. This is useful in UNIX environments, where the host must see a carrier before it will send a logon screen to the terminal. The carrier sense feature also plays an important role in troubleshooting, where the presence or absence of a carrier indicates the validity of your line connection.

Patton electronic 1006 — 2.2 DESCRIPTION diagram (page 3)
Fig. 2
Patton electronic 1006 — 2.2 DESCRIPTION diagram (page 3)
Fig. 3
1. Blue 2 - Orange 3 - Black 4 - Red 5 - Green 6 - Yellow 7 - Brown 8 - Slate
1. Blue 2 - Yellow 3 - Green 4 - Red 5 - Black 6 - White

Measuring only 2.5” x 1.2” x .75” (6.4 x 3.0 x 1.9 cm), the Model 1006 is housed in a pop-open ABS plastic case. The Model 1006 comes with a male or female DB-9 connector and a choice of interfaces (RJ-11 jack, RJ-45 jack or terminal blocks with strain relief). For surge handling capability, the Model 1006S is compliant with IEC 801.5 level 2, 1kV.

Figure 1. AT&T standard modular color codes

Page 4 of the Patton electronic 1006 user manual — 3.1.2 TWISTED PAIR CONNECTION USING TERMINAL BLOCKS
Page 4 · click to enlarge
Page 4
1. Open the unit by gently inserting a screwdriver between the DB-9 connector and the lip of the plastic case (see below). You don't have to worry about breaking the plastic, but be careful not to bend the D-sub connector.

RJ-1 1 SIGNAL RJ-45 SIGNAL

1----------------GND † 1----------------N/C 2----------------RCV2----------------GND †

3----------------XMT+ 3----------------RCV4----------------XMT4----------------XMT+ 5----------------RCV+ 5----------------XMT6----------------GND † 6----------------RCV+ 7----------------GND †

Patton electronic 1006 — RJ-1 1 SIGNAL RJ-45 SIGNAL diagram (page 4)
Fig. 4
Patton electronic 1006 — RJ-1 1 SIGNAL RJ-45 SIGNAL diagram (page 4)
Fig. 5

8 N/C

When connecting two Model 1006s, it is necessary to use a “cross- over” cable. The diagram below shows how a crossover cable should be constructed for an environment where both Model 1006s use a 4-wire RJ-11 connector. Similar logic should be followed when using RJ-45 connectors or a combination of the two.

SIGNAL PIN# COLOR ‡ COLOR PIN# SIGNAL

GND† 1 Blue White 6 GND†

RCV- 2 Yellow Red 4 XMT- XMT+ 3 Green Black 5 RCV+ XMT- 4 Red Yellow 2 RCV- RCV+ 5 Black Green 3 XMT+ GND† 6 White Blue 1 GND†

Once the unit has been opened, you will be able to see the terminal blocks located at the rear of the PC board.

†Connection to ground is optional

‡Standard color codes—yours may be different

2. Strip the outer insulation from the twisted pairs about one inch from the end.

3.1.2 TWISTED PAIR CONNECTION USING TERMINAL BLOCKS

If your RS-232 application requires you to connect two pairs of bare wires to the Model 1006, you will need to open the case to access the terminal blocks. The following instructions will tell you how to open the case, connect the bare wires to the terminal blocks and fasten the strain relief collar in place so that the wires won't pull loose.

Patton electronic 1006 — 3.1.2 TWISTED PAIR CONNECTION USING TERMINAL BLOCKS diagram (page 4)
Fig. 6
Patton electronic 1006 — 3.1.2 TWISTED PAIR CONNECTION USING TERMINAL BLOCKS diagram (page 4)
Fig. 7
3. Strip the insulation on each of the twisted pair wires about .25”.
Page 5 of the Patton electronic 1006 user manual — RJ-1 1 SIGNAL RJ-45 SIGNAL
Page 5 · click to enlarge
Page 5
4. Connect one pair of wires to XMT+ and XMT- (transmit positive and negative) on the terminal block, making careful note of which color is positive, and which color is negative.
8. Place the 2 halves of the strain relief assembly on either side of the telephone wire and press together very lightly. Slide the assembly so that it is about 2 inches from the terminal posts and press together firmly. If your cable diameter is too small or too large for our strain relief, please contact our technical support. We have strain relief assemblies to accommodate most cable diameters.
5. Connect the other pair of wires to RCV+ and RCV- (receive positive and negative) on the terminal block, again making careful note of which color is positive and which color is negative.
Patton electronic 1006 — RJ-1 1 SIGNAL RJ-45 SIGNAL diagram (page 5)
Fig. 8

Ultimately, you will want to construct a two pair crossover cable

that connects the two short hauls as shown below:

Patton electronic 1006 — RJ-1 1 SIGNAL RJ-45 SIGNAL diagram (page 5)
Fig. 9

XMT + RCV+ XMT - RCV - G G RCV - XMT - RCV + XMT +

6. If there is a shield around the telephone cable, it may be connected to “G” on the terminal block. To avoid ground loops, we recommend connecting the shield only at the computer end. A ground wire is not necessary for proper operation of the Model 1006.
9. Insert the strain relief assembly with the wire going through it into the slot in the bottom half of the modem case and set it into the recess in the case.
7. When you finish connecting the wires to the terminal block, the assembly should resemble the diagram below:
Patton electronic 1006 — RJ-1 1 SIGNAL RJ-45 SIGNAL diagram (page 5)
Fig. 10
Patton electronic 1006 — RJ-1 1 SIGNAL RJ-45 SIGNAL diagram (page 5)
Fig. 11
Page 6 of the Patton electronic 1006 user manual — 3.3 OPERATING THE MODEL 1006
Page 6 · click to enlarge
Page 6

APPENDIX A

10. TIP the top half of the case as necessary to place it over the strain relief assembly. Do not snap the case together yet.

PATTON MODEL 1006 SPECIFICATIONS

Transmission FormatAsynchronous
Data Rate0 to 19,200 bps (no strapping)
DistanceSee table below
Surge ProtectionCompliant with IEC 801.5 level 2, 1kV (Model
Control SignalCTS (Pin 8) turns ON immediately after the terminal

raises RTS (Pin 7); DSR (Pin 6) turns on when it is powered-up (connected); DCD (Pin 1) turns ON after detecting the receive signal from the line

11. Insert one captive screw through a saddle washer and then insert the entire piece through the hole in the DB-9 end of the case. Snap that side of the case closed. Repeat the process for the other side. This completes cable installation.

Transmit Line: 4-wire, unconditioned line Transmit Mode: Full duplex, 4-wire Transmit Level: 0 dBm RS-232 Connection: DB-9 Line Connection: RJ-11 or RJ-45 jack or 5 screw terminal posts

3.2 CONNECTION TO THE RS-232 INTERFACE

(4 wires and 1 ground) and a strain relief insert Power Supply: No external power required, uses ultra low power

Once you have connected the twisted pair wires correctly, simply plug the Model 1006 directly into the DB-9 port of the RS-232 device. Remember to insert and tighten the two captive connector screws.

from EIA data and control signals Size: 2.5” x 1.2” x 0.75” (6.4 x 3.0 x 1.9 cm)

3.3 OPERATING THE MODEL 1006

Once the Model 1006 is properly installed, it should operate transparently—as if it were a standard cable connection. Operating power is derived from the RS-232 data and control signals; there is no “ON/OFF” switch.

1006S Only)

Page 7 of the Patton electronic 1006 user manual — DIRECTION STANDARD “DTE” SETTING DIRECTION
Page 7 · click to enlarge
Page 7

APPENDIX B

APPENDIX C

PATTON MODEL 1006 CABLE RECOMMENDATIONS

PATTON MODEL 1006 PIN/SIGNAL ASSIGNMENTS

DIRECTION STANDARD “DCE” SETTING DIRECTION

The Patton Model 1005 operates at frequencies of 20kHz or less and has been performance tested by Patton technicians using twisted- pair cable with the following characteristics:

1. (FG) Frame Ground 2- (TD) Transmit Data To Model 1006 3- (RD) Receive Data From Model 1006 4- (RTS) Request to Send To Model 1006 5- (CTS) Clear to Send From Model 1006 6- (DSR) Data Set Ready From Model 1006 7- (SG) Signal Ground 8- (DCD) Data Carrier Detect From Model 1006 To Model 1006 Data Term. Ready (DTR) - 20
Patton electronic 1006 — APPENDIX B diagram (page 7)
Fig. 12
Patton electronic 1006 — APPENDIX B diagram (page 7)
Fig. 13

Wire Gauge Capacitance Resistance

19 AWG/.9mm 83nf/mi or 15.72 pf/ft. .0163 Ohms/ft. 22 AWG/.6mm 83nf/mi or 15.72 pf/ft. .0326 Ohms/ft. 24 AWG/.5mm 83nf/mi or 15.72 pf/ft. .05165 Ohms/ft.

To gain optimum performance from the Model 1006, please keep the following guidelines in mind:

  • Always use twisted pair wire —this is not an option.
  • Use twisted pair wire with a capacitance of 20pf/ft or less.

DIRECTION STANDARD “DTE” SETTING DIRECTION

  • Avoid twisted pair wire thinner than 26 AWG (i.e. avoid higher AWG numbers than 26)
1. (FG) Frame Ground 2- (TD) Transmit Data From Model 1006 3- (RD) Receive Data To Model 1006 4- (RTS) Request to Send From Model 1006 5- (CTS) Clear to Send To Model 1006 6- (DSR) Data Set Ready To Model 1006 7- (SG) Signal Ground 8- (DCD) Data Carrier Detect To Model 1006 From Model 1006 Data Term. Ready (DTR) - 20
  • Use of twisted pair with a resistance greater than the above specifications may cause a reduction in maximum distance obtainable. Functionality should not be affected.
  • Environmental factors too numerous to mention can affect the maximum distances obtainable at a particular site. Use “maximum distance” figures as a general guideline only.
Page 8 of the Patton electronic 1006 user manual — APPENDIX B
Page 8 · click to enlarge
Page 8

APPENDIX B

PATTON MODEL 1006 BLOCK DIAGRAM

Patton electronic 1006 — APPENDIX B diagram (page 8)
Fig. 14

Copyright © 1998 Patton Electronics Company

All Rights Reserved

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Patton electronic 1006

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Patton electronic 1006

Be the first to ask — other owners or our team will answer.

Original document

Patton electronic 1006 manual PDF

8 pages·107 KB·Network Card·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…