EN
Patton electronic logo
Official user manual

Patton electronic Modem Eliminator (1000)

8 pages·75 KB·Network Card·PDF·ENDEFRITNLJA
Patton electronic Modem Eliminator (1000)
Table of Contents 36 sections MODEL 1000 and 1000S · Ultra Miniature Asynchronous · TECHNICAL SUPPORT · Short Range Modems · … ShowHide
Page 1 of the Patton electronic Modem Eliminator (1000) user manual — SALES OFFICE
Page 1 · click to enlarge
Page 1

MODEL 1000 and 1000S

Ultra Miniature Asynchronous

Patton electronic Modem Eliminator (1000) — MODEL 1000 and 1000S diagram (page 1)
Fig. 1 · MODEL 1000 and 1000S

TECHNICAL SUPPORT

Short Range Modems

http://www.patton.com

SALES OFFICE

MANUAL

USER

Doc. #023021UC

C E R T I F I E D

We manufacture one of the widest selections of data communications

powered and self-powered short range modems, fiber optic modems, interface

following ways to tell us how you like this product and how we can meet your

Electronics is BABT and ISO 9001 certified. We meet and exceed the highest

multiplexers, transceivers, hubs, print servers and much more. We produce

We would like to hear from you. Please contact us in any of the

We are committed to a quality product at a quality price. Patton

It is our business to serve you. If you are not satisfied with any

aspect of this product or the service provided from Patton Electronics or its

Thank you for purchasing Patton Electronics products! We do

appreciate your business. I trust that you find this user manual helpful.

products in the world including CSU/DSU's, network termination units,

converters, baluns, electronic data switches, data-line surge protectors,

these products at our Gaithersburg, MD, USA, facility, and can custom

7622 Rickenbacker Drive Gaithersburg, MD 20879 USA

MailPatton Electronics Company
Webhttp://www.patton.com

P.S. Please tell us where you purchased this product:

Support E-mailsupport@ patton.com
Sales E-mailsales@ patton.com

Phone - Sales (301) 975-1000

Phone - Support (301) 975-1007

Fax(301) 869-9293

manufacture products for your unique needs.

product needs today and in the future.

standards in the industry (CE, UL, etc.).

distributors, please let us know.

Thank you.

Burton A.Patton

Show 14 more labels / short text on this page
(301) 975-1000 · (301) 975-1007 · Part #07M1000-C · Revised 7/29/97 · Certified Company · An ISO-9001 · _________________________________________________________ · _________________________________________________________ · _________________________________________________________ · _________________________________________________________ · _________________________________________________________ · _________________________________________________________ · Dear Valued Customer, · Vice President
Page 2 of the Patton electronic Modem Eliminator (1000) user manual — 1.2 CE NOTICE
Page 2 · click to enlarge
Page 2

Return Materials Authorization number on the outside of the shipping

Patton Electronics' technical staff is also available to answer any

questions that might arise concerning the installation or use of your

Model 1000. Technical Service hours8AM to 5PM EST, Monday

All warranty and non-warranty repairs must be returned freight

prepaid and insured to Patton Electronics. All returns must have a

Technical Service at (301) 975-1007; http://www.patton.com: or,

container. This number may be obtained from Patton Electronics

support@patton.com.

through Friday.

1.2 SERVICE

accepted.

free from defects, and will—at our option—repair or replace the product

This warranty is limited to defects in workmanship or materials, and

product. Patton Electronics specifically disclaims all other warranties,

expressed or implied, and the installation or use of this product shall be

The Model 1000 generates and uses radio frequency energy, and if

one of the following measuresmoving the computing equipment away

from the receiver, re-orienting the receiving antenna and/or plugging the

does not cover customer damage, abuse or unauthorized modification.

recourse shall be repair or replacement as described above. Under no

condition shall Patton Electronics be liable for any damages incurred

by the use of this product. These damages include, but are not limited

interference will not occur in a particular installation. If the Model 1000

receiving equipment into a different AC outlet (such that the computing

consequential damages arising from the use of or inability to use this

not installed and used properly—that is, in strict accordance with the

with the specifications in Subpart J of Part 15 of FCC rules, which are

designed to provide reasonable protection from such interference in a

does cause interference to radio or television reception, which can be

that it is in compliance with the Electromagnetic Compatibility (EMC)

directive and the Low Voltage Directive (LVD) of the Union European

Patton Electronics warrants all Model 1000 components to be

television reception. The Model 1000 has been tested and found to

comply with the limits for a Class A computing device in accordance

interface, the user is encouraged to try to correct the interference by

The CE symbol on your Patton Electronics equipment indicates

(EU). A Certificate of Compliance is available by contacting Patton

manufacturer's instructions—may cause interference to radio and

determined by turning the power off or disconnecting the RS-232

If this product fails or does not perform as warranted, your sole

commercial installation. However, there is no guarantee that

should it fail within one year from the first date of shipment.

to, the followinglost profits, lost savings and incidental or

1.0 WARRANTY INFORMATION

deemed an acceptance of these terms by the user.

equipment and receiver are on different branches).

1.1 RADIO AND TV INTERFERENCE

Technical Support.

1.2 CE NOTICE

Page 3 of the Patton electronic Modem Eliminator (1000) user manual — 2.2 DESCRIPTION
Page 3 · click to enlarge
Page 3

connected to the Model 1000 is a modem or multiplexer (or is wired like

internal jumpers or configuration switches to set, so there is no need to

open the case to configure the unit (you may need to open the case for

Figure 1, below, shows the location of the DCE/DTE switch on the

If the device connected to the Model 1000 is a PC, terminal or host

one), set the switch to "DTE". This setting causes the Model 1000 to

computer (or is wired like one), set the switch to "DCE". This setting

The Model 1000 is designed to be easy to use. There are no

necessary for operation is proper setting of the external DCE/DTE

Figure 1Location of Key Components on Model 1000 Printed Circuit Board

PC board, as well as the location of the terminal block and surge

behave like Data Terminal Equipment and transmit data on pin 2.

Equipment and transmit data on pin 3 (Default Setting is “DCE”).

accessible DCE/DTE switch (see diagram below). If the device

wire connection—refer to section 4.0). The only configuration

For your convenience, the Model 1000 has an externally

causes the Model 1000 to behave like Data Communications

Figure 2Model 1000 DCE/DTE Switch

3.0 CONFIGURATION

DCE DTE

DCE DTE

3.1 SETTING THE DCE/DTE SWITCH

suppressors ("S" model only).

DCE/DTE

switch.

arise during installation or use of this product, please do not hesitate to

duplex at data rates to 19.2 Kbps over 2 twisted pair. Requiring no AC

enclosure options allow terminations to be via RJ-11, RJ-45 or terminal

blocks. A unique strain relief prevents thin twisted pairs from breaking

that uses the latest in bi-directional, clamping, transient suppressors to

warranted for One Year parts and labor. If any questions or problems

The Model 1000 Asynchronous Short Range Modem uses the

allows easy connection to any device without opening the unit. Three

The Model 1000S is a surge protected version of the Model 1000

Thank you for your purchase of this Patton Electronics product.

modem performance in a low profile package. The unit operates full

With an externally accessible DCE/DTE switch, the Model 1000

power or batteries, the Model 1000 supports distances to 17 miles

contact Patton Electronics Technical Support at (301) 975-1007.

latest surface mount technology to attain high quality short range

protect itself and connected equipment against harmful transient

  • 2.1 FEATURES
  • New design uses Surface Mount Technology
  • Full duplex
  • Data rates to 19.2 Kbps
  • Range to 17 miles (27.2 km)
  • No AC power required
  • External DCE/DTE switch
  • Uses modular plugs (RJ-11 or RJ-45) or terminal posts for twisted pair connections

discharges. For surge handling capability, the Model 1000S is

This product has been thoroughly inspected and tested and is

  • Very thin case (.75") for closely spaced computer ports
  • New snap-together, pop-open case
  • Surge protected (Model 1000S only)
  • Made in USA

2.0 GENERAL INFORMATION

compliant with IEC 801.5 level 2, 1kV.

2.2 DESCRIPTION

or pulling loose.

(27.2km).

Show 6 more labels / short text on this page
Suppressors · (1000S only) · Surge · Terminal · Block · Switch
Page 4 of the Patton electronic Modem Eliminator (1000) user manual — 4.0 INSTALLATION
Page 4 · click to enlarge
Page 4

should be constructed for an environment where both Model 1000s use

SIGNAL PIN# COLOR ‡ COLOR PIN# SIGNAL

bare wires to the Model 1000, you will need to open the case to access

a 4-wire RJ-11 connector. Similar logic should be followed when using

the terminal blocks. The following instructions will tell you how to open

the case, connect the bare wires to the terminal blocks, and fasten the

"crossover" cable. The diagram below shows how a crossover cable

GND† 1 Blue White 6 GND†

RCV- 2 Yellow Red 4 XMT-

XMT+ 3 Green Black 5 RCV+

XMT- 4 Red Yellow 2 RCV-

RCV+ 5 Black Green 3 XMT+

GND† 6 White Blue 1 GND†

4.1.2 TWISTED PAIR CONNECTION USING TERMINAL BLOCKS

If your RS-232 application requires you to connect two pairs of

When connecting two Model 1000s, it is necessary to use a

RJ-11 SIGNAL RJ-45 SIGNAL

1----------------GND † 1----------------N/C 2----------------RCV2----------------GND †

3----------------XMT+ 3----------------RCV4----------------XMT4----------------XMT+ 5----------------RCV+ 5----------------XMT6----------------GND † 6----------------RCV+ 7----------------GND †

strain relief collar in place so that the wires won't pull loose. 1 2 3 4 5 6 7 8

8 N/C

RJ-45 connectors or a combination of the two.

‡Standard color codes—yours may be different

†Connection to ground is optional

ready to connect the Model 1000 to your system. This section tells you

how to properly connect the Model 1000 to the twisted pair and RS-232

gauges may limit distance). Standard dial-up telephone circuits, or

The RJ-11 and RJ-45 connectors on the Model 1000's twisted pair

interface are pre-wired for a standard TELCO wiring environment (see

Once you have properly configured the DTE/DCE switch, you are

The Model 1000 supports data-only communication between two

1. These units work in pairs. Therefore, you must have one Model 1000 at each end of a two twisted pair interface.
2. To function properly, the Model 1000 needs two twisted pair of metallic wire. The pairs must be unconditioned, dry metallic wire,

leased circuits that run through signal equalization equipment are

RS-232 devices at distances to 17 miles (27.2 km) and data rates to

different twisted pair interfacesRJ-11 jack, RJ-45 jack and terminal

between 19 and 26 AWG (.4mm to .9mm) (the higher number

For your convenience, the Model 1000 is available with three

19.2 Kbps. There are two essential requirements for installation:

4.1.1 TWISTED PAIR CONNECTION USING RJ-11 OR RJ-45

Figure 3). The table on the following page shows the signal/pin

Figure 3. Pin Number Assignments for RJ11 and RJ45 Modular Jacks

4.1 CONNECTION TO THE TWISTED PAIR INTERFACE

RJ-11 Jack RJ-45 Jack

interfaces, and how to operate the Model 1000.

4.0 INSTALLATION

1 2 3 4 5 6

blocks with strain relief.

not acceptable.

relationships.

Page 5 of the Patton electronic Modem Eliminator (1000) user manual — SIGNAL PIN# COLOR ‡ COLOR PIN# SIGNAL
Page 5 · click to enlarge
Page 5
Patton electronic Modem Eliminator (1000) — SIGNAL PIN# COLOR ‡ COLOR PIN# SIGNAL diagram (page 5)
Fig. 2
Patton electronic Modem Eliminator (1000) — SIGNAL PIN# COLOR ‡ COLOR PIN# SIGNAL diagram (page 5)
Fig. 3

recommend connecting the shield at one end only. A ground wire is not

Patton electronic Modem Eliminator (1000) — SIGNAL PIN# COLOR ‡ COLOR PIN# SIGNAL diagram (page 5)
Fig. 4
3. Strip the insulation on each of the twisted pair wires about .25" as shown in Figure 7.
4. Connect one pair of wires to XMT+ and XMT- (transmit positive and negative) on the terminal block, making careful note of which color
5. Connect the other pair of wires to RCV+ and RCV- (receive positive and negative) on the terminal block, again making careful note
7. When you finish connecting the wires to the terminal block, the assembly should resemble the diagram in Figure 8, below:
6. If there is a shield around the telephone cable, it may be connected to "G" on the terminal block. To avoid ground loops, we
Figure 8Proper Twisted Pair Connections to the Model 1009 Terminal Blocks
Figure 7Stripping the Insulation from Each Twisted Pair

of which color is positive and which color is negative.

necessary for proper operation of the Model 1000.

is positive, and which color is negative.

Figure 5How to Use a Small Flathead Screwdriver to Finish Opening the Model 2070 Case

Figure 4: How to Use a Small Flathead Screwdriver to Begin to Open the Model 2070 Case

1. Open the unit by gently inserting a screwdriver between the DB-25 connector and the lip of the plastic case (see Figures 4 and 5,
2. Strip the outer insulation from the twisted pairs about one inch from the end as shown in Figure 6.

below). You don't have to worry about breaking the plastic, but be

Once the unit has been opened, you will be able to see the

Figure 6Stripping the Outer Insulation from the Twisted Pair

terminal blocks located at the rear of the PC board.

careful not to bend the D-sub connector.

Page 6 of the Patton electronic Modem Eliminator (1000) user manual — +RCVG -XMT+
Page 6 · click to enlarge
Page 6
Patton electronic Modem Eliminator (1000) — 4.2 CONNECTION TO THE RS-232 INTERFACE diagram (page 6)
Fig. 5

RS-232, make sure it is a straight through cable of the shortest possible

connected the twisted pair wires correctly, simply plug the Model 1000

power is derived from the RS-232 data and control signals; there is no

10. TIP the top half of the case as necessary to place it over the strain relief assembly (see Figure 11, below). Do not snap the case
11. Insert one captive screw through a saddle washer and then insert the entire piece through the hole in the DB-25 end of the case.
(NoteIf you must use a cable to connect the Model 1000 to the

Snap that side of the case closed. Repeat the process for the other

Once you have configured the Model 1000 for DTE or DCE and

transparently—as if it were a standard cable connection. Operating

remember to insert and tighten the two captive connector screws.

directly into the DB-25 port of the RS-232 device. After doing so,

Once the Model 1000 is properly installed, it should operate

4.2 CONNECTION TO THE RS-232 INTERFACE

side. This completes cable installation.

length—we recommend 6 feet or less).

4.3 OPERATING THE MODEL 1000

"ON/OFF" switch.

together yet.

8. Place the 2 halves of the strain relief assembly on either side of the telephone wire and press together very lightly (See Figure 9,

support. We have strain relief assemblies to accommodate most cable

terminal posts and press together firmly. If your cable diameter is too

9. Insert the strain relief assembly with the wire going through it into the slot in the bottom half of the modem case and set it into the

small or too large for our strain relief, please contact our technical

below). Slide the assembly so that it is about 2 inches from the

Figure 10Positioning the Model 1000 Inside the Plastic Case
Figure 9Re-connecting the Strain Relief Assembly

recess in the case (see Figure 10, below).

+RCVG -XMT+

diameters.

Page 7 of the Patton electronic Modem Eliminator (1000) user manual — APPENDIX A
Page 7 · click to enlarge
Page 7
  • Environmental factors too numerous to mention can affect the maximum distances obtainable at a particular site. Use “maximum

and has been performance tested by Patton technicians using twisted-

The Patton Model 1000 operates at frequencies of 20kHz or less

24 AWG/.5mm 83nf/mi or 15.72 pf/ft. .05165 Ohms/ft.

To gain optimum performance from the Model 1000, please keep

  • Avoid twisted pair wire thinner than 26 AWG (i.e. avoid higher AWG numbers than 26)

19 AWG/.9mm 83nf/mi or 15.72 pf/ft. .0163 Ohms/ft.

22 AWG/.6mm 83nf/mi or 15.72 pf/ft. .0326 Ohms/ft.

PATTON MODEL 1000 CABLE RECOMMENDATIONS

  • Use of twisted pair with a resistance greater than the above specifications may cause a reduction in maximum distance

Wire Gauge Capacitance Resistance

  • Use twisted pair wire with a capacitance of 20pf/ft or less.
  • Always use twisted pair wire—this is not an option.

obtainable. Functionality should not be affected.

distance” figures as a general guideline only.

APPENDIX B

pair cable with the following characteristics:

the following guidelines in mind:

power from EIA data and control

Line ConnectionRJ-11 or RJ-45 jack or 5 screw

ground) and a strain relief insert

Data Rate (bps)Wire Gauge 19 AWG ( 0.9 mm)24 AWG (0.5 mm)26 AWG (0.4 mm) 19,2006.2(9.9)3.7(5.9)1.2(1.9) 9,600 4,800 2,400 1,2007.5(12.0) 8.7(13.9) 11.8(18.9) 17.0(27.2)4.9(7.8) 5.6(9.0) 8.0(12.8) 11.8(18.9)2.5(4.0) 3.7(5.9) 4.9(7.8) 8.0(12.8)
DTE/DCE ConnectionEither a male or female DB-25

terminal posts (4 wires and 1

Power SupplyNone required, uses ultra low

PATTON MODEL 1000 SPECIFICATIONS

Size2.2" x 1.75" x 0.75" (5.6 x 4.4 x 1.9 cm)

24 AWG (0.5 mm) 26 AWG (0.4 mm) 19 AWG ( 0.9 mm)

19,200 6.2(9.9) 3.7(5.9) 1.2(1.9) 9,600 7.5(12.0) 4.9(7.8) 2.5(4.0) 4,800 8.7(13.9) 5.6(9.0) 3.7(5.9) 2,400 11.8(18.9) 8.0(12.8) 4.9(7.8) 1,200 17.0(27.2) 11.8(18.9) 8.0(12.8)

Model 1000 Distance Table in Miles (km)

Transmission FormatAsynchronous
Data Rate0 to 19.2 Kbps

APPENDIX A

Transmit Level0 dBm
Show 4 more labels / short text on this page
Wire Gauge · signals · Data Rate · (bps)
Page 8 of the Patton electronic Modem Eliminator (1000) user manual — PATTON MODEL 1000 INTERFACE SETTINGS
Page 8 · click to enlarge
Page 8
Patton electronic Modem Eliminator (1000) — PATTON MODEL 1000 BLOCK DIAGRAM diagram (page 8)
Fig. 6

PATTON MODEL 1000 BLOCK DIAGRAM

APPENDIX D

Patton electronic Modem Eliminator (1000) — PATTON MODEL 1000 BLOCK DIAGRAM diagram (page 8)
Fig. 7
Patton electronic Modem Eliminator (1000) — PATTON MODEL 1000 BLOCK DIAGRAM diagram (page 8)
Fig. 8
1. (FG) Frame Ground 2- (TD) Transmit Data To Model 1000
7. (SG) Signal Ground 8- (DCD) Data Carrier Detect From Model 1000 To Model 1000 Data Term. Ready (DTR) - 20
1. (FG) Frame Ground 2- (TD) Transmit Data From Model 1000
7. (SG) Signal Ground 8- (DCD) Data Carrier Detect To Model 1000 From Model 1000 Data Term. Ready (DTR) - 20

PATTON MODEL 1000 INTERFACE SETTINGS

APPENDIX C

Patton Electronics Company · All Rights Reserved · Copyright ©

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Patton electronic Modem Eliminator (1000)

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Patton electronic Modem Eliminator (1000)

Be the first to ask — other owners or our team will answer.

Original document

Patton electronic Modem Eliminator (1000) manual PDF

8 pages·75 KB·Network Card·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…