Instruction/ maintenance manual of the product INTELLISENSE HEM-705CP Omron
Go to page of 28
A utoma tic Blood Pr essure Monit or with Prin ter Model HEM-705CP INSTRUCTION MANU AL R ENGLISH ESP AÑOL HEM-705CP-IM-US 7/19/05 9:26 AM Page 1.
TITLE 2 TITLE T ABLE OF C ONTENTS Bef or e Using the Monitor Introduction ........................................................................................ 3 Important Safety Notes ...............................................................
INTRODUCTION 3 Thank you for purchasing the Omron ® HEM-705CP Intellisense ® Automatic Blood Pressure Monitor with Printer F ill in for futur e ref erence DA TE PURCHASED: ______ SERIAL NUMBER: ________ Staple y our purchase rec eipt here . Y our ne w digital blood pressure monitor uses the oscillometric method of blood pressure measurement.
4 IMPORT ANT SAFET Y NO TES T o assur e the corr ect use of the pr oduct basic safety measur es should always be followed including the pr ecautions listed below: þ Read all information in the instruction book and an y other literature included in the box before using the unit.
BEFORE T AKING A MEASUREMENT 5 T o ensure a reliable reading follow these recommendations: 1. A void eating, smoking, and e x ercising for 30 minutes before taking a measurement. Rest for at least 15 minutes before taking the measurement. 2. Stress raises blood pressure.
TITLE TITLE KNOW Y OUR UNIT ST AR T Button Paper Feed Pulse Rate Print Graph Date/T ime Display Heart Symbol Air T ube Memory Button S ystolic Blood Pressure ON/OFF Button Set Date/T ime Adjust Date/T.
TITLE TITLE BA T TERY INST ALL A TION/REPLA CEMENT 1. Press the ▼ OPEN indicator on the battery co ver and slide the cov er of f in the direction of the arro w . 2. Install 4 “ AA” size batteries so the + (positi v e) and - (neg ati ve) polarities match the polarities of the battery compartment as indicated.
TITLE 8 TITLE C ONNEC TING THE PRINTER 1. Remov e the printer cord from around the printer unit. 2. Connect the printer to the blood pressure monitor . Insert the cable plug with the indicator facing upw ard. CA UTION: Inserting the cable plug in an y other position will damage the monitor .
9 L O ADING THE PRINTER P APER This printer uses OMR ON ® thermal paper , part number 90TRP . Use only this thermal paper or thermal paper of similar size, width 38mm, roll diameter not to e xceed 26mm. NO TE: For information on where to purchase printer paper visit our website at www .
SET TING THE D A TE AND TIME 10 The Blood Pressure Monitor automatically stores up to 28 measurement v alues with the date and time. Set the monitor to the current date and time before taking a measurement for the f irst time. If the current date and time is not set, a default date and time will display .
TITLE SET TING THE D A TE AND TIME 11 3. SETTING THE MONTH Press the ADJUST b utton to adv ance by increments of one month. Press the SET b utton to set the current month. The day flashes on the display . 4. SETTING THE D A Y Press the ADJUST b utton to adv ance by increments of one day .
TITLE 12 TITLE TITLE APPL Y ING THE ARM CUFF 1. Make sure the air plug is securely inserted in the main unit. 2. Remo ve tight-f itting clothing from your upper arm. 3. Sit in a chair with your feet flat on the floor . Place your arm on a table so the cuf f is le v el with your heart.
5. Pull the cuf f so the top and bottom edges are tightened e v enly around your arm. 6. When the cuf f is positioned correctly , press the se wn hook material FIRML Y against the pile side of the cuf f. 7. Make certain the cuf f fits snugly around your arm.
TITLE 14 TITLE TITLE T AKING A MEASUREMENT The monitor automatically determines your ideal inflation le v el. In rare circumstances when a higher inflation may be necessary , the monitor automatically re-inflates the cuf f up to 30mmHg higher than the initial inflation and restarts the measurement.
15 TITLE TITLE TITLE T AKING A MEASUREMENT ST ART 4. When the measurement is complete, the arm cuf f completely deflates. Y our blood pressure and pulse rate are displayed. 5. Pr ess the ON/OFF button to turn the monitor of f. NO TE: The monitor will automatically turn of f after f i ve minutes.
Every time you complete a measurement the monitor store s t h e b l o o d pressure and pulse rate in the memory . The Blood Pressure Monitor automatically stores up to 28 measurement v alues. When 28 sets of measurement v alues are stored in the memory , the oldest record is deleted to sa ve the most recent measurement v alues.
17 TITLE TITLE USING THE PRINTER The HEM-705CP printer unit has the capability to print all the of measurement v alues stored in the memory of the Blood Pressure Monitor . NO TES: • The correct date and time must be set up on the monitor before taking a reading.
TITLE 18 TITLE USING THE PRINTER 2. T O PRINT ALL THE MEASUREMENT V ALUES Pr ess the ALL D A T A button. The numeric printout will list all of the readings stored in the memory starting with the oldest reading to the most recent reading follo wed by the a verage of all the stored readings.
19 TITLE TITLE USING THE PRINTER 3 . T O PRINT A GRAPH OF ALL MEASUREMENT V ALUES Pr ess the GRAPH button. The graph will list all of the readings stored in the memory .
TITLE TITLE CARE AND MAINTENANCE T o keep your digital blood pr essur e monitor in the best condition and pr otect the unit fr om damag e follow the dir ections listed below: • K eep the monitor in the storage case when not in use. • Do not f or cefully bend the arm cuf f or air tube.
21 TITLE TITLE TITLE ERROR INDICA T ORS SY MBOL CA USE C ORREC TION Monitor did not detect pulse rate Remov e the arm cuf f. Refer to “ Applying the arm cuff” on page 12. W ait 2-3 minutes. T ake another measurement. Cuf f under -inflated Remove the arm cuf f.
TITLE 22 22 TITLE TITLE TROUBLESHOO TING TIPS PROBLEM CA USES SOL UTIONS No po wer . W orn batteries Incorrect battery installation Replace all 4 "AA" batteries. Reference page 7. Check the battery installation or proper placement of the battery polarities.
QUICK REFERENCE GUIDE T o ensure a reliable reading, av oid eating, smoking, and e xercising for 30 minutes before taking a measurement. Y ou should try to measure your blood pressure at the same time each day . A v oid taking measurements during stressful times.
QUICK REFERENCE GUIDE 24 5. Press the ON/OFF b utton. Display symbols appear . 6. Press the ST AR T b utton. The cuf f starts to inflate automatically . Remain still and do not talk during the measurement. NO TE: T o stop the inflation or measurement, push the ST AR T/ST OP b utton.
25 TITLE TITLE TITLE FCC ST A TEMENT Note: PO TENTIAL FOR RADIO/TELEVISION INTERFERENCE (for U.S.A. only) This product has been tested and found to comply with the limits for a Class B digital de vice, pursuant to part 15 of the FCC rules.
TITLE 26 TITLE W ARRANTY Y our HEM-705CP , IntelliSense Automatic Blood Pressure Monitor , excluding the monitor cuf f, is warranted to be free from defects in materials and w orkmanship appearing within 5 years from the date of purchase, when used in accordance with the instructions provided with the monitor .
NO TE: These specif ications are subject to change without notice. 27 TITLE TITLE SPECIFICA TIONS Model: HEM-705CP Display: LCD Digital Display Measurement Range: Pressure: 0 to 299 mmHg Pulse: 40 to .
Made in China Manufactured by OMR ON Distrib uted by: OMR ON HEAL THCARE, INC. 1200 Lak eside Dri ve Bannockb urn, Illinois 60015-1243 www .omronhealthcare.
An important point after buying a device Omron INTELLISENSE HEM-705CP (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Omron INTELLISENSE HEM-705CP yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Omron INTELLISENSE HEM-705CP - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Omron INTELLISENSE HEM-705CP you will learn all the available features of the product, as well as information on its operation. The information that you get Omron INTELLISENSE HEM-705CP will certainly help you make a decision on the purchase.
If you already are a holder of Omron INTELLISENSE HEM-705CP, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Omron INTELLISENSE HEM-705CP.
However, one of the most important roles played by the user manual is to help in solving problems with Omron INTELLISENSE HEM-705CP. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Omron INTELLISENSE HEM-705CP along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center