EN
Omega Engineering logo
Official user manual

Omega Engineering Security Alarm System (ISD9001)

6 pages·2.3 MB·Smoke Alarm·PDF·EN
Omega Engineering Security Alarm System (ISD9001)
Table of Contents 6 sections SM · User’s Guide · OM-EL-WiFi-TC WiFi Thermocouple Temperature Data Logging Sensor · FEATURES · … ShowHide
Page 1 of the Omega Engineering Security Alarm System (ISD9001) user manual — SM
Page 1 · click to enlarge
Page 1

SM

User’s Guide

Omega Engineering Security Alarm System (ISD9001) — SM diagram (page 1)
Fig. 1

Extended Warranty · Program

Page 2 of the Omega Engineering Security Alarm System (ISD9001) user manual — SM
Page 2 · click to enlarge
Page 2
Omega Engineering Security Alarm System (ISD9001) — SM diagram (page 2)
Fig. 2
Page 3 of the Omega Engineering Security Alarm System (ISD9001) user manual — www.omega.com
Page 3 · click to enlarge
Page 3

OM-EL-WiFi-TC WiFi Thermocouple Temperature Data Logging Sensor

Omega Engineering Security Alarm System (ISD9001) — OM-EL-WiFi-TC WiFi Thermocouple Temperature Data Logging Sensor diagram (page 3)
Fig. 3 · OM-EL-WiFi-TC WiFi Thermocouple Temperature Data Log…
Omega Engineering Security Alarm System (ISD9001) — OM-EL-WiFi-TC WiFi Thermocouple Temperature Data Logging Sensor diagram (page 3)
Fig. 4 · OM-EL-WiFi-TC WiFi Thermocouple Temperature Data Log…

FEATURES

Omega Engineering Security Alarm System (ISD9001) — FEATURES diagram (page 3)
Fig. 5
  • Temperature data logging sensor with K type thermocouple probe and integrated display
  • Supports J,K,N,T type thermocouple probes
  • Easy sensor set-up using the free PC software application (downloadable from <a href="http://www.omega.com" rel="nofollow noopener" target="_blank">www.omega.com</a>)
  • Wirelessly stream data to PC via WiFi
  • View and analyze multiple sensors, including immediate graphing of historic data
  • Selectable measurement scale °C / °F
  • Temperature accuracy ±1.5°C /0.1°F(probe dependent)
  • Temperature measurement resolution to 0.1°C
  • Temperature display resolution to 0.1°C (-99.9 to +999.9°C)
Omega Engineering Security Alarm System (ISD9001) — FEATURES diagram (page 3)
Fig. 6
  • Temperature measurement range -270 to +1300°C (-454 to +2372°F) (probe dependent)
  • Operating temperature range -20 to +60°C (-4 to +140°F)
  • Configurable high and low alarms with indicator
  • Delayed alarms capability
  • Audit function
  • Maximum and minimum readings
  • Low battery indicator
  • WiFi connection indicator
  • Signal strength indicator
  • 802.11b compliant
  • Rechargeable internal lithium polymer battery
Omega Engineering Security Alarm System (ISD9001) — FEATURES diagram (page 3)
Fig. 7
  • Fully featured LCD segment display
  • Sensor memory stores all data even if WiFi is temporarily disconnected
  • USB port used for recharging (can only be recharged when unit is between 0 - 40˚C)
  • Firmware upgradable via USB (downloadable from the Omega website)
  • PC can be switched off without loss of data
  • Supplied with wall bracket, sticky pad, micro USB lead and thermocouple probe (type K)
  • Supported Security Protocols WEP, WPA/WPA2 – PSK

The OM-EL-WiFi-TC sensor measures the temperature of the environment in which the probe is situated. Data is streamed wirelessly over any WiFi network and can be viewed on a PC using our free software package. During configuration, the sensor will search for an existing wireless network while physically connected to the PC. It can then be placed anywhere within range of the network. If the sensor temporarily loses connectivity with the network, it will log readings until it is able to communicate again with the PC application (max 30 days at 10 second sample interval). Logged data is retained if the battery goes flat. Although the OM-EL-WiFi sensors have an impressive range this can be increased by using WiFi extenders.

www.omega.com

Specifications liable to change without prior warning Data Sheet - Issue 03L 08/2013 SL Applies to OM-EL-WiFi-TC Page 1 of 2

Page 4 of the Omega Engineering Security Alarm System (ISD9001) user manual — www.omega.com
Page 4 · click to enlarge
Page 4

The OM-EL-WiFi-TC is a low powered battery device. When configured using typical transmission periods (e.g. once every hour) the sensor will operate for up to one year (at room temperature). The battery can then be recharged via a PC or USB +5V wall adapter using the USB lead provided or can be permanently powered by the USB wall adapter.

The software installed on the PC will allow set-up, data logging and data review. Set-up features will include sensor name, °C/°F, sample rate, and high/low alarms. Once configured, historic data can be viewed via the graphing tool or exported into Excel. This software is available to download for free from www.omega.com

The sensor is a freestanding unit, however, it can be attached to a wall or vertical surface using the bracket and screws / sticky pad provided.

It is supplied with a thermocouple probe with an attachment so that it can be securely fixed to flat surfaces. It is perfect for a wide range of temperature monitoring situations e.g. manufacturing processes, cold/hot storage and laboratory conditions. The probe is removable so alternatives can also be used to meet specific requirements providing they operate within the same temperature range. The OM-EL-WiFi-TC supports J, K, N and T thermocouple probes.

SpecificationsMinimumTypicalMaximumUnit Battery life1*Year USB supply voltage4.555.5Vdc Operating temperature range (sensor only)-20 (-4)+60 (+140)°C (°F) Logging period (user configurable)10 sec10 min12 hrs Transmission period (user configurable)1 min1 hr24 hrs Temperature measurement range (probe dependent)-270 (-454)+1300 (+2372)°C (°F) Temperature measurement resolution0.1°C Temperature display resolution (-99.9 to 999.9°C)0.1°C Temperature accuracy (probe dependent)±1.5°C

* Dependant on transmission rate, may be less with frequent transmissions Warning - do not exceed operating temperatures

PHYSICAL DIMENSIONS All dimensions in inches (mm)

Omega Engineering Security Alarm System (ISD9001) — PHYSICAL DIMENSIONS All dimensions in inches (mm) diagram (page 4)
Fig. 8 · PHYSICAL DIMENSIONS All dimensions in inches (mm)

3.83” (97.3)

Omega Engineering Security Alarm System (ISD9001) — PHYSICAL DIMENSIONS All dimensions in inches (mm) diagram (page 4)
Fig. 9 · PHYSICAL DIMENSIONS All dimensions in inches (mm)

1.03” (26.36)

2.80” (71.3)

www.omega.com

Specifications liable to change without prior warning Data Sheet - Issue 03L 08/2013 SL Applies to OM-EL-WiFi-TC Page 2 of 2

Page 5 of the Omega Engineering Security Alarm System (ISD9001) user manual — PHYSICAL DIMENSIONS All dimensions in inches (mm)
Page 5 · click to enlarge
Page 5
Omega Engineering Security Alarm System (ISD9001) — PHYSICAL DIMENSIONS All dimensions in inches (mm) diagram (page 5)
Fig. 10 · PHYSICAL DIMENSIONS All dimensions in inches (mm)
Page 6 of the Omega Engineering Security Alarm System (ISD9001) user manual — PHYSICAL DIMENSIONS All dimensions in inches (mm)
Page 6 · click to enlarge
Page 6
Omega Engineering Security Alarm System (ISD9001) — PHYSICAL DIMENSIONS All dimensions in inches (mm) diagram (page 6)
Fig. 11 · PHYSICAL DIMENSIONS All dimensions in inches (mm)

Ask about the Omega Engineering Security Alarm System (ISD9001)

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Omega Engineering Security Alarm System (ISD9001)

Be the first to ask — other owners or our team will answer.

Original document

Omega Engineering Security Alarm System (ISD9001) manual PDF

6 pages·2.3 MB·Smoke Alarm·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…