TEMPERATURE

Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies Wire: Thermocouple, RTD & Thermistor Calibrators & Ice Point References Recorders, Controllers & Process Monitors Infrared Pyrometers

PRESSURE, STRAIN AND FORCE

Transducers & Strain Gauges Load Cells & Pressure Gauges Displacement Transducers Instrumentation & Accessories

FLOW/LEVEL

Rotameters, Gas Mass Flowmeters & Flow Computers Air Velocity Indicators Turbine / Paddlesheel Systems Totalizers & Batch Controllers

pH/CONDUCTIVITY

An OMEGA Technologies Company

pH Electrodes, Testers & Accessories Benchtop/Laboratory Meters Controllers, Calibrators, Simulators & Pumps Industrial pH & Conductivity Equipment

http://www.omega.com e-mail: [email protected]

DATA ACQUISITION

Data Acquisition & Engineering Software Communications-Based Acquisition Systems Plug-in Cards for Apple, IBM & Compatibles Datalogging Systems Recorders, Printers & Plotters

HEATERS

Heating Cable Cartridge & Strip Heaters Immersion & Band Heaters Flexible Heaters Laboratory Heaters

ENVIRONMENTAL MONITORING AND CONTROL

Metering & Control Instrumentation Refractometers Pumps & Tubing Air, Soil & Water Monitors Industrial Water & Wastewater Treatment pH, Conductivity & Dissolved Oxygen Instruments

TX802RTDF-CU10-F-2 SERIES

2 WIRE RTD TRANSMITTER

M-3789/0302

Page 2 of the Omega Engineering Temperature Transmitter (TX802RTDF) user manual — WARRANTY/DISCLAIMER
Page 2 · click to enlarge
Page 2

omega.com TM

WARRANTY/DISCLAIMER

OMEGA

OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA Warranty adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA’s customers receive maximum coverage on each product.

OMEGAnetSM On-Line Service http://www.omega.com

Internet e-mail info@omega.com

Servicing North America: USA: One Omega Drive, Box 4047 ISO 9001 Certified Stamford, CT 06907-0047 Tel: (203) 359-1660 FAX: (203) 359-7700 e-mail: info@omega.com

If the unit should malfunction, it must be returned to the factory for evaluation. OMEGA’s Customer Service Department will issue an Authorized Return (AR) number immediately upon phone or written request. Upon examination by OMEGA, if the unit is found to be defective it will be repaired or replaced at no charge. OMEGA’s WARRANTY does not apply to defects resulting from any action of the purchaser, including but not limited to mishandling, improper interfacing, operation outside of design limits, improper repair, or unau- thorized modification. This WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence of being damaged as a result of excessive corrosion; or current, heat, moisture or vibra- tion; improper specification; misapplication; misuse or other operating conditions outside of OMEGA’s con- trol. Components which wear are not warranted, including but not limited to contact points, fuses, and triacs.

Canada: 976 Bergar Laval (Quebec) H7L 5A1 Tel: (514) 856-6928 FAX: (514) 856-6886 e-mail: canada@omega.com For immediate technical or application assistance: USA and Canada: Sales Service: 1-800-826-6342 / 1-800-TC-OMEGASM Customer Service: 1-800-622-2378 / 1-800-622-BESTSM Engineering Service: 1-800-872-9436 / 1-800-USA-WHENSM TELEX: 996404 EASYLINK: 62968934 CABLE: OMEGA

OMEGA is pleased to offer suggestions on the use of its various products. However, OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for any damages that result from the use of its products in accordance with information provided by OMEGA, either verbal or written. OMEGA warrants only that the parts manufactured by it will be as specified and free of defects. OMEGA MAKES NO OTHER WARRANTIES OR REPRESEN- TATIONS OF ANY KIND WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT THAT OF TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DIS- CLAIMED. LIMITATION OF LIABILITY: The remedies of purchaser set forth herein are exclusive and the total liability of OMEGA with respect to this order, whether based on contract, warranty, negliegence, indemnification, strict liability or otherwise, shall not exceed the purchase price of the component upon which liability is based. In no event shall OMEGA be liable for consequential, incidental or special damages.

Mexico and Latin AmericaTel: (95) 800-TC-OMEGA SM FAX: (95) 203-359-7807 En Espanol: (203) 359-7803 e-mail: espanol@ omega.com

Servicing Europe:

Benelux: Postbus 8034, 1180 LA Amstelveen, The Netherlands Tel: (31) 20 6418405 FAX: (31) 20 6434643 Toll Free in Benelux: 06 0993344 e-mail: nl@omega.com

CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a “Basic Component” under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) in medical applications or used on humans, or misused in any way, OMEGA assumes no responsibility as set forth in our basic WARRANTY/DISCLAIMER language, and additionally, purchaser will indemnify OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the Product(s) in such a manner.

Czech Republic: ul. Rude armady 1868, 733 01 Karvina-Hranice, Czech Republic Tel: 420 (69) 6311627 FAX: 420 (69) 6311114 e-mail: czech@omega.com

France: 9, rue Denis Papin, 78190 Trappes Tel: (33) 130-621-400 FAX: (33) 130-699-120 Toll Free in France: 0800-4-06342 e-mail: france@omega.com

RETURN REQUESTS/INQUIRIES Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department. BEFORE RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN AUTHORIZED RETURN (AR) NUMBER FROM OMEGA’S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID PROCESSING DELAYS). The assigned AR number should then be marked on the outside of the return package and on any correspondence. The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent break- age in transit.

Germany/Austria: Daimlerstrasse 26, D-75392 Deckenpfronn, Germany Tel: 49 (07056) 3017 FAX: 49 (07056) 8540 Toll Free in Germany: 0130 11 21 66 e-mail: germany@omega.com

FOR NON-WARRANTY REPAIRS, consult OMEGA for current repair charges. Have the following information available BEFORE con tacting OMEGA: 1. P.O. number to cover the COST of the repair, 2. Model and serial number of product, and 3. Repair instructions and/or specific problems relative to the product.

FOR WARRANTY RETURNS, please have the following information available BEFORE contact- ing OMEGA: 1. P.O. number under which the product was PUR CHASED, 2. Model and serial number of the product under warranty, and 3. Repair instructions and/or specific problems relative to the product.

United Kingdom: 25 Swannington Road, P.O. Box 7, Omega Drive, ISO 9001 Certified Broughton Astley, Leicestershire, Irlam, Manchester, LE9 6TU, England M44 5EX, England Tel: 44 (1455) 285520 Tel: 44 (161) 777-6611 FAX: 44 (1455) 283912 FAX: 44 (161) 777-6622 Toll Free in England: 0800-488-488

e-mailuk@ omega.com

It is the policy of OMEGA to comply with all worldwide safety and EMC/EMI regulations that apply. OMEGA is constantly pursuing certification of its products to the European New Approach Directives. OMEGA will add the CE mark to every appropriate device upon certification.

OMEGA’s policy is to make running changes, not model changes, whenever an improvement is possible. This affords our customers the latest in technology and engineering. OMEGA is a registered trademark of OMEGA ENGINEERING, INC. Copyright 1996 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied, photocopied, reproduced, translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without prior written consent of OMEGA ENGINEERING, INC.

The information contained in this document is believed to be correct but OMEGA Engineering, Inc. accepts no liability for any errors it contains, and reserves the right to alter specifications without notice. WARNING: These products are not designed for use in, and should not be used for, patient connected applications.

Page 3 of the Omega Engineering Temperature Transmitter (TX802RTDF) user manual — (Ω)
Page 3 · click to enlarge
Page 3

TX802RTD(F) CU10-F-2 Transmitter.

The Proper Installation & Maintenance.

Isolating Linearised, 3 Wire RTD

Input, to 4~20 Output Loop Powered Transmitter.

MOUNTING. (1) Mount in a clean environment in an electrical cabinet on DIN or EN mounting rail. (2) Do not subject to vibration or excess temperature or humidity variations. (3) Avoid mounting in cabinets with power control equipment. (4) To maintain compliance with the EMC Directives the transmitter must be mounted in a fully enclosed steel cabinet. The cabinet must be properly earthed, with appropriate input \ output entry points, filtering, and cabling.

Features. l CU10 input. l Isolated Input to Output 2.0kV l Field Programmable Input Ranges. TX802RTD l High Accuracy. l Linear With Temperature l 40~200mV Output Test Signal. l LED Indication of Loop Current. l Low Cost. l Compact DIN Rail Mount Enclosure. l Available Standard or Special Calibration. l Reverse Polarity Protection. l Corrosion Proofed Circuit Board & Components by Isonel 642. (Except Terminals & DIP Switches)

WIRING. (1) All cables should be good quality overall screened INSTRUMENTATION CABLE with the screen earthed at one end only. (2) Signal cables should be laid a minimum distance of 300mm from any power cables. (3) For 2 wire current loops Austral Standard Cables B5102ES is recommended. For 3 wire transmitters and RTD's Austral Standard Cables B5103ES is recommended. (4) It is recommended that you do not ground current loops and use power supplies with ungrounded outputs. (5) Lightning arrestors should be used when there is a danger from this source. (6) Refer to diagrams for connection information.

RTD'S. (1) Avoid locating the RTD where it will be in a direct flame. (2) Locate it where the average temperature will be measured. It should be representative of the mass. (3) Immerse the RTD far enough so that the measuring point is entirely in the temperature to be measured; nine to ten times the diameter of the protection tube is recommended. Heat that is conducted away from the measuring point causes an error in reading.

COMMISSIONING. (1) Once all the above conditions have been carried out and the wiring checked apply power to the transmitter loop and allow five minutes for it to stabilize. (2) Due to differences in cable resistance in the RTD legs or errors within the RTD itself a small zero error may occur (usually less than 0.5C). To remove this error use a calibration standard RTD at the same immersion depth and adjust the Zero trimpot in the top of the transmitter enclosure with a small screwdriver, until the two levels agree. (Clockwise to increase the output reading and anticlockwise to decrease the output reading)

Graph Of Maximum Load Enclosure Dimensions. Versus Power Supply.

Omega Engineering Temperature Transmitter (TX802RTDF) — (Ω) diagram (page 3)
Fig. 2

1 6 0 0

Omega Engineering Temperature Transmitter (TX802RTDF) — (Ω) diagram (page 3)
Fig. 3

1 4 0 0

1 2 0 0

MAINTENANCE. (1) Check RTD's in place - with a calibration RTD at the same immersion depth. (2) Do it regularly - at least once every 6 months. (3) Replace defective protection tubes - even if they look good they may not be air or gas tight. (4) Check cables entering the RTD sensor head.

1 0 0 0

(Ω)

1 2 8 1 6 2 0 2 4 2 8 3 2 3 6 4 0

Quality Assurance Programme. The modern technology and strict procedures of the ISO9001 Quality Assurance Programme applied during design, development, production and final inspection grant the long term reliability of the instrument.

Maximum Load · Power Supply (Vdc)

Page 4 of the Omega Engineering Temperature Transmitter (TX802RTDF) user manual — 3 B
Page 4 · click to enlarge
Page 4

TX802RTD ONLY

Input Programming Pt100 only If the input range is not listed in the programming table, use the following formulae to work out the Zero and Span DIP switch settings for gain.

TX802RTD Specifications. RTD Input CU10 RTD (3 Wire Type) Standard. Sensor Current = 0.8mA. Lead Wire Resistance = 10Ω/Wire Max. Field Programmable Zero: -200C (-400F) to 200C (400F). (TX802RTD Only.) Field Programmable Span: 20C (40F) to 400C (800F). (TX802 RTD Only.) Suitable for 2 Wire Connection. (Offset Calibration needed.) Other Types of RTD Available. JIS Pt100, Pt250, Pt500, Pt1000, CU10, CU100, Ni100 or specify. Output -mA 2 wire 4~20mA. (Loop Powered.) -mV 40~200mV µ 4~20mA. (Indicative Test Signal Only.) Other Output Voltages Available. e.g. 1~5V. Power Supply 8~40Vdc. Supply Voltage Sensitivty

deg C Span Gain = 1200 deg F Spain Gain = 2400 deg C High - deg C Low deg F High - deg F Low

deg C Zero Gain = deg C Low deg F Zero Gain = deg F Low 5 10

Gain Value12481632 DIP Switch No.123456

If Zero Gain is 1/ +ve Put S3-1 OFF (Positive Offset) 2/ -ve Put S3-1 ON (Negative Offset)

So if a gain value of 28 is required, put DIP switch No's 3, 4, 5 OFF (ie, gains of 4 + 8 + 16 = 28) and all the other DIP switches ON. Dip switches are accessed by seperating the two halves of the enclosure

Input Range Programming Table Pt100 only. Notes:1/ Switch status 1 = ON, 0 = OFF, X = DON'T CARE. 2/ Input ranges with '*' beside them require more adjustment by the Span trimpot.

Input Range C (Put S5-2 OFF)Input Range F (Put S5-2 ON)S1-ZeroS2-SpanS3-Function 1234561234561234 0~20C0~40F111111110000X 0~25C0~50F111111111100X.k.k. 0~30C0~60F111111111010XITeaea 0~40C0~80F111111100001XErBr 0~50C0~100F111111111001XHr Br 0~60C0~120F111111110101XNoso 0~70C*0~140F*111111011101XEnsn 0~75C0~150F111111111101XRSeSe 0~80C0~160F111111000011XHEE 0~90C*0~180F*111111010011XFAALAL 0~100C0~200F111111110011XCC 0~110C0~220F111111001011XRSNS 0~120C0~240F111111101011XOWNW 0~125C*0~250F*111111101011XFOO 0~150C0~300F111111111011X1'DD 0~200C 0~250C*0~400F 0~500F*1 11 00 10 01 11 11 1X XO '' for' for 0~300C 0~400C 0~600C0~600F 0~800F 0~1200F1 1 11 1 11 1 11 1 11 1 11 1 11 0 11 0 00 1 11 1 11 1 11 1 1X X XET Tto '1to '0 -10~10C-20~20F1011111100001SSetSet -10~20C-20~40F1011111110101S..k. -10~40C-20~80F1011111110011Uaka -20~20C-40~40F1101111000011Irere -20~30C-40~60F1101111110011LCBr B -25~25C-50~50F0101111110011Eoro -25~50C-50~100F0101111111011Cnsns -30~20C-60~40F1001111110011RSeSe -50~50C -50~100C-100~100F -100~200F1 10 01 10 01 11 11 11 10 10 01 11 11 1FOLELE -50~150C -100~100C-100~300F -200~200F1 10 11 00 11 01 11 10 00 01 11 11 11 1'0'PSCAPSCA -100~200C -200~200C -200~400C-200~400F -400~400F -400~800F1 1 11 1 10 1 11 0 00 1 11 0 01 0 11 0 00 1 11 1 11 1 11 1 11 1 1TOfor Ufor U 20~40C40~80F1101111100000T0'1' 50~100C100~200F1010111110010Eo 'o ' 50~150C100~300F1010111100110Stt 100~200C200~400F1101011100110etet 100~500C200~1000F1101010011110SS

Accurate to

Examples of Input Connection.

Terminations.

Omega Engineering Temperature Transmitter (TX802RTDF) — TX802RTD ONLY diagram (page 4)
Fig. 4
Input Output 1 A T 6 2 B - 5 3 B + 4 ZERO SPAN+ mV - 16 2 35 4E.g. Loop Indicator, + With 4~20mA Input. - 2000V Isolation Barrier 3 Wire RTD-8~40Vdc Power Supply +

1 A

I n p u t 1 A 2 B 3 B

2 B

Link 2 & 3

O u t p u t 4 +mA 5 -mA 6 mV TEST

3 B

Plan View of TX802RTD Adjustments (Pt100 only)

Omega Engineering Temperature Transmitter (TX802RTDF) — 3 B diagram (page 4)
Fig. 5

OFF ON Gain = 1 Gain = 0 Gain = 2 Gain = 0 Gain = 4 Gain = 0 Gain = 8 Gain = 0 Gain = 16 Gain = 0 Gain = 32 Gain = 0

OFF ON - Ve Offset + Ve Offset Celsius Fahrenheit Upscale Break Downscale Break 1 2 3 4 5 6 ON

OFF ON Gain = 1 Gain = 0 Gain = 2 Gain = 0 Gain = 4 Gain = 0 Gain = 8 Gain = 0 Gain = 16 Gain = 0 Gain = 32 Gain = 0

25 Turn Trimpot for ZERO ±10% 25 Turn Trimpot for SPAN ±10%

Input

Ask about the Omega Engineering Temperature Transmitter (TX802RTDF)

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Omega Engineering Temperature Transmitter (TX802RTDF)

Be the first to ask — other owners or our team will answer.

Original document

Omega Engineering Temperature Transmitter (TX802RTDF) manual PDF

4 pages·580 KB·Sensor·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…