Video Security Intercom System for the Home

USA & Canada (800) 421-1587 & (800) 392-0123
(760) 438-7000 - Toll Free FAX (800) 468-1340

SHOCK HAZARD
This sign alerts user about un-insulated “dangerous voltage” that poses risk of electric shock.
this product.
Read Instructions - All safety and operating instructions should be read before installing or operating the VMC1 Video Intercom system. Retain Instructions - The safety and operating instructions should be retained for future reference. Heed Warnings - All warnings on the appliance and in the operating instructions should be adhered to. Follow Instructions - All operating and use instructions should be followed. Water and Moisture - The appliance should not be used near water - for example: near bathtub, washbowl, kitchen sink, laundry tub, in a wet basement, or near a swimming pool, and the like. Doing so can create fire or shock hazards and impair the warranty. Attachments - Do not use attachments not recommended by the product manufacturer as they may cause hazards. Ventilation - The appliance should be situated so that its location or position does not interfere with its proper ventilation. For example, the appliance should not be situated on a bed, sofa, rug, or similar surface that may block the ventilation openings: or, placed in a built in installation, such as a bookcase or cabinet that may impede the flow of air to the ventilation openings. Heat - The appliance should be situated away from heat sources such as radiators, heat registers, stoves, or other appliances (including amplifiers) that produce heat. Power Sources - The appliance should be connected to a power supply only of the type described in the operating instructions or as marked on the appliance. Grounding or Polarization - Precautions should be taken so that the grounding or polarization means of an appliance is not defeated.

Power Lines - Locate outdoor antennas away from power lines. Outdoor Antenna Grounding - If an outside antenna is connected to the receiver, be sure the antenna system is grounded so as to provide some protection against voltage surges and built up static charges. Section 810 of the National Electrical Code, ANSI/NFPA No. 70 1984, provides information with respect to proper grounding of the mast and supporting structure, grounding of the lead in wire to an antenna discharge unit, size of grounding conductors, location of antenna discharge unit, connection to grounding electrodes, and requirements for the grounding electrode (see fi gure). Object and Liquid Entry - Never push objects of any kind into this product through openings as they may touch dangerous voltage points or short out parts that could result in a fi re or electric shock. Never spill liquid of any kind on the product.
Keep this manual in a safe place for future reference. To replace this manual, download available from Linear Web site:www.linearcorp.com

✔DO ensure that all instructions have been followed before
✔DO NOT SPLICE CABLES. Splices are unreliable and
power is applied to system. The installation shall be carried out in accordance with all applicable installation rules. ✔DO use only Cat-5 & RG-6 and specifi ed wires called out in
defeat the signal isolation properties of the cable. ✔DO keep cables at least 18 inches from fl uorescent light
fi xtures, Dimmer controls, and all other wiring. This includes AC wiring, security cable, and other control wires. These can cause a “hum” or “buzzing” sound. ✔DO keep cables away from objects such as heating and air
these instructions. The cable is designed and constructed with electrical specifi cations necessary for proper audio performance. ✔DO use only a damp cloth to clean the exterior plastics on
conditioning ducts, metal construction plates, and anything else with sharp edges that can damage the cables. ✔DO follow the grounding and bonding requirements
the VMC1 Master Station and Room Stations. ✔DO NOT use liquid or aerosols.
✔DO make gradual bends of the cable where necessary -- no
established by Electrical Code TIA standard 607, and equipment manufacturer’s specifi cations. ✔DO NOT locate the VMC1 Master Station or Room Stations
sharper than 1” radius. ✔DO dress the cables neatly with cable ties or Velcro™
on an exterior wall. ✔DO NOT locate the VMC1 Master Station or Room Stations
wraps. Use loose or moderate pressure. ✔DO use cable-pulling lubricant only for cable runs that may
otherwise require great force to install. When cable lubricant is used, read the instructions to be sure it is compatible with the cable jacket material (PVC or FEP). ✔DO avoid stressing cable conductors, limit pulling tension to
in any wall cavity with any other electrical wiring in the cavity. ✔DO NOT attach non line-level audio devices or non M&S
authorized equipment to the system. ✔DO NOT power up Master Station until all stations are
25 pounds or less as specifi ed by EIA/TIA-568A standard. Pull cables gradually and with constant tension, taking care not to crush or pinch bundles. ✔DO use grommets to protect the cable where passing
connected. ✔DO NOT splice or repair cables damaged during wire
pulling, install a new cable. ✔DO NOT coil or bundle the cables. This can cause electronic
through metal studs or anything that can possibly damage them. ✔DO test every installed cable run with a cable tester. “Toning”
feedback. ✔DO NOT over-tighten the screws for the stations or the
alone is not acceptable. ✔DO label every termination point. Use a unique identifi er
intercom Master Station to prevent cracking. ✔DO NOT install any station or speaker cables inside the 120
for each cable run. It will make moves, adds, changes, and troubleshooting easier. ✔DO support horizontal cable bundles using board supports,
VAC transformer enclosure. ✔DO NOT tie cables to electrical conduits or lay cables on
electrical fi xtures. ✔DO NOT allow the cable to be sharply bent or kinked at any
J-hooks, or cable trays. ✔DO have signal cables cross at right angles to power cables
time. ✔DO NOT install cables “taut” anywhere. Good installation
to minimize induced interference. ✔DO always obey all local and national fi re and building
should have cables loose, but never sagging. ✔DO NOT run signal and power cables parallel without
codes. Be sure to “fi re-stop” all cables that penetrate a fi re- wall. Use plenum-rated cable where mandated. ✔DO have a licensed electrician to run a 120 VAC line from A
adequate separation to minimize interference. ✔DO NOT exert more than 25 pounds of tension on 4-pair
DEDICATED 15-AMP BREAKER to the VMC1 power supply. ✔DO Use Cat-5 wire for all VMC1 wire runs.
cables. ✔DO NOT step on Cat-5 cable during installation.
✔DO label all wire runs. Connecting the wires to the VMC1
✔DO NOT overtighten the cable ties, apply cable ties loosely,
master, room station, or door station incorrectly may result in system damage. ✔DO NOT STAPLE CABLES. Staples cause shorts.
with random spacing. ✔DO NOT untwist the wire pairs in Cat-5 cable more than 1/2”
to avoid crosstalk.
Keep this manual in a safe place for future reference. To replace this manual, download available from Linear Web site:www.linearcorp.com





The VMC1H installation rough-in prepares the home to accommodate the video intercom system. A VMC1MB mounting bracket is necessary for the Master Station. Room stations and the Alloy Color Video Door Station (VMC1VDS) can be mounted directly onto fi nished walls. All other door stations require a rough-in enclosure (VMC1HR). The VMC1HR is also recommended for installing room stations in new construction or installations where the drywall has not yet been installed.





226804 250106-2

Tools Most are required for purposes of this installation, but may vary according to installer preferences.

500 50 250 10 50 250 600 + -

The VMC1 System Designed for installation in new homes, the VMC1 is a Whole House Color Video Security Intercom system that provides room to room communication, multiple camera support, basic home automation controls, and video security for mid to large residential applications. VMC1 provide years of service and security for the homeowner as many people move into ‘smart home’ environment. New housing takes advantage of state of the art electronics, internet, and security applications such as video surveillance and monitoring. VMC1 provides up to 20 remote intercom stations, three video camera stations, and offers music and communication for the whole house. With multiple 12 volt Control Outputs, VMC1 can trigger lights, monitors, voice and text message alerts, and e-mail door chime alerts delivered to a smart phone. VMC1 offers a wide range of capacities with expanded options, accessories, and recommended parts. (See Appendix A).
Room Stations To avoid audio feedback, Room Stations should be kept at least 10 feet away from other stations. Never have more than one station in any one room and avoid mounting stations in the same wall cavity (i.e. directly below and above one another in a two-story house). A suitable height is generally 4.5 feet from the fl oor to the center of the unit. For Room Stations mounted on wood frame walls, place near a stud to allow for adequate support. For tiled surfaces, install a wall box before lining or tiling the walls. Cut the tiles to the inside dimensions of the wall box. Where Room Stations are mounted outside and are exposed to the weather, the fi tting of weatherproof covers is recommended (p/n DSWS). Stations must not be installed in saunas.
Door Stations Door Stations are best located adjacent to the front door or at the front gate at a suggested height of 4’-6” and may require a wall box depending upon the surface to which they are to be affi xed. Door Stations are weather resistant, but should not be exposed directly to rain or extreme weather. Any station exposed to the weather requires a weather shield. When equipped with the appropriate weather shield the Door Station is designed to meet ANSI/IEC 60529 IP31 weather proof standards.
It is important that each step of the installation be carefully completed by the installer. In the event you need troubleshooting assistance, please call our technical support staff at 1-800-421-1587.
General Information The following general procedures must be observed in relation to the location and installation of VMC1 components:
Where stations are to be installed outdoors, appropriate measures to provide protection from the weather are to be taken.
Gates and Entrances Where stations are to be installed in brick or concrete columns at a front gate, the cable should be run in conduit from the station to below ground level and back to the house.
The power supply should be located in an area with suffi cient space for heat dissipation.
Cameras For Door Stations fi tted with cameras, consideration must be given to the viewing area of the camera taking factors such as lighting and sun exposure into account.
Guidelines for maximum cable lengths as set out in this manual are to be observed to avoid the possibility of operating problems due to excessive cable voltage drop.
Interference The circuitry of the intercom is designed to minimize the effects of Radio Frequency Interference (RFI); and there will be minimal and occasional radio frequency interference as power outages, lightning storms, and any electrical apparatus can affect the system. To reduce instances of interference, reduce any unwanted audible buzz in audio appliances such as microphone amplifi er, speaker amplifi er, car radio, telephones etc, you add on-board EMI fi lters or special layout techniques to help bypass EMI or improving RF immunity. Most circuits have integrated RF fi lters or special design that prevents demodulation of high-frequency carriers. The use of microwaves, cell phones, cable television, bug zappers, even heating pads in close proximity, can create interference.
Power Supply The Power Supply should be attached to the VMC1MB as directed. Improper installation of the Power Supply can lead to unit malfunction and void the warranty. The Power Supply needs suffi cient space to dissipate heat effectively.
AM & FM Antennas The antenna arrangement is critical to the installation for quality radio reception. Place AM and FM antennas at the highest point of the roof and at least 6 feet away from any electrical or intercom wiring. Both AM and FM antennas are directional, and correct positioning requires some experimentation to achieve the best possible result. Antenna wires should also be positioned at the highest and most accessible point in the roof. Allow additional cable at the mounting bracket for termination, at least 3 feet for the Master Station.
Master Station The Master Station should be positioned at a suggested height of 4-1/2’ to 5-1/2’ from the fl oor to the center of the unit. As all wiring from other stations is generally terminated at the rear of the Master Station, the wall should be no less than 3 inches in depth. Use the VMC1MB to provide adequate support for the unit.

Cables and Wiring Excellent locations to run cables include:
Cable Type and Confi guration The general intercom functions for VMC1 can be cabled using Cat-5 or Cat-6 cables. If required, 6-conductor telephone cables can be used provided the system is confi gured for 6-wire operation.
Be sure to clearly tag all cables to identify any damaged cables or other system faults. See the table below for Cat-5 wire color recommendations.


VMC1MB Master Station Mounting Bracket The VMC1MB mounts fl ush with the wall stud and holds the Master Station and Power Supply (See Figure 1). Position the VMC1MB at a suggested height of 4-1/2 to 5-1/2 feet from the fl oor to center of the unit. As all wiring from other stations is generally terminated at the rear of the Master Station, the wall should be no less than 3 inches deep. If required, install additional wood shims or metal rough-in enclosures to allow for adequate support of the Master Station.
VMC1MB Installation - Unfi nished Wall Install the VMC1MB fl ush with the front of the wall stud and fasten in place with screws as shown. After drywall has been installed, cut out an opening to the inside dimensions of the VMC1MB (7-1/4” x 11.”).
wiring behind it. Do not install in a brick wall. For wall tiling around the Master Station, ensure that it is mounted either completely within or clear of tile to avoid an uneven surface. Be sure to allow at least 10” of space below Master Station Bracket and fi rebreaks for Power Supply. This is also necessary for clearance when installing the Master Station Mounting Bracket into pre-cut drywall opening.
The VMC1MB has a correct orientation, so review Figures 1 and 2 to be sure it is right side up.

MASTER STATION BRACKET MOUNT BRACKET FLUSH WITH FRONT OF WALL STUD
TRACE THIS AREA AS A TEMPLATE FOR MASTER STATION OPENING ON DRYWALL (7-1/4” x 11”)
POWER SUPPLY (TE6D) MOUNTS TO FLANGE ON MASTER STATION BRACKET
MOUNTING HEIGHT FROM FLOOR TO CENTER LINE OF BRACKET

VMC1MB Installation - Finished Wall Cut out an opening in the drywall (Height 7-1/4” x Width 11”) but do not cut right up against the wall stud. Allow 5/8” clearance between drywall opening and stud. This ensures that drywall will overlap bracket (See Figure 2). Slide the VMC1MB vertically, then turn clockwise 90˚. Mount in place onto stud using fasteners as shown. Hang Power Supply on VMC1MB in the lower right corner as shown. It may be necessary to lightly tap Power Supply in place onto VMC1MB fl ange with a hammer.

TRACE THIS AREA AS A TEMPLATE FOR MASTER STATION OPENING ON DRYWALL (7-1/4” x 11”)
THEN TURN BRACKET 90° CLOCKWISE AND MOUNT TO STUD
DRYWALL OVERLAPS BRACKET HANG POWER SUPPLY ON VMC1MB BRACKET AS SHOWN. USE HAMMER TO LIGHTLY TAP INTO PLACE ON MASTER STATION BRACKET FLANGE

Room Station Mounting The Room Stations are normally mounted at a height from the fl oor of: 4-1/2’ to 5’. The Room Stations are not designed to be installed outdoors.
Room Station Installation - Finished Wall Identify the location where the Room Station is to be installed.
Cut a 3-1/2” x 7-3/4” rectangular hole in the drywall. When possible, one short edge should be situated against a wall stud to provide added support when installing the Room Station.
Room Station Installation - Unfi nished Wall For an unfi nished wall it is recommended that the VMC1HR rough-in enclosure be used. Identify the location where the Room Station is to be installed.
Pull the wire through the hole and attach to the drywall so it will not fall back into the wall cavity.
Room Station Auxiliary Activation When operating in single digit mode, each Room Station can activate the Auxiliary Control Output (CO) triggers at the Master Station.
Attach the Rough-In Enclosure to the stud using the two inner pre-punched holes (see Figure 3). The outside holes on the wings of the box are to be used to mount the room station and not to attach the Rough-in Enclosure to the stud.
Pull a yellow 18 gauge wire from the VMC1MB to the Room Station location. Following this color convention will assist in the fi nal installation of the VMC1 system.
Pull the Cat-5 wires through the hole in the back of the Rough- in Enclosure and make a knot so they do not fall back into the wall once the drywall is installed.
Pull the yellow wire through the hole in the back of the Rough-In Enclosure and loop it through so it does not fall back into the wall once the drywall is installed.
After drywall is installed, cut out an opening to the inside dimensions of the VMC1HR utilizing the inside of the box as a guide (see Figure 3 ).

USE INNER HOLES FOR MOUNTING ROUGH-IN ENCLOSURE TO STUD

VMC1VDS Door Station Rough-in The VMC1VDS is a metal door station with a 90 degree horizontal viewing area. It is normally mounted at a height from the fl oor of: 55” – 60”. When installing the VMC1VDS be aware of the camera location and the direction of sunlight and other ambient light. Direct sun or lighting into the lens of the VMC1VDS camera may impact the video quality. Additionally, exposure to extreme weather conditions is not recommended. For added protection against weather, the VMC1VDS should be equipped with a VDSWS-T weather shield. The installation of the VDSWS-T is shown in Figure 4.
small metal tab will drop out of the chassis. Be sure to re-install tab into camera chassis slot before re-assembly.


VMC1VDS-S/BZ Door Station Rough-in The VMC1VDS-S and VMC1VDS-BZ incorporate a wide angle 120 degree horizontal viewing camera into a Door Station. It is normally mounted at a height from the fl oor of: 55” – 60”. Installation of this unit on an exterior wall requires 4 screws and anchors (See Figure 6). When installing these units, be aware of the camera location and the direction of sunlight and other ambient light. Direct sun or light pointed into the lens of the VMC1VDS camera may impact video quality. Additionally, exposure to extreme weather conditions is not recommended. For added protection against weather, the VMC1VDS-S and VMC1VDS-BZ should be equipped with a DSWS weather shield. The installation of the DSWS is provided in the VMC1 Finish Out Guide.

USE INNER HOLES FOR MOUNTING ROUGH-IN ENCLOSURE TO STUD

TE6D Power Supply The Power Supply unit is pre-wired and self contained, and the wires are tucked inside. To access connection wires, open the Power Supply unit by removing four screws as shown in Figure 6. In the unlikely case that the TE6D electrical connectors become unplugged, the 3-pin and 6-pin connector blocks can be re-installed in their respective locations on the power supply board. Plug connectors in as shown.
Power Supply Connections The 6-pin connector is the low voltage (13.8 VDC, 3.8 amp) output from the TE6D Power Supply unit:
The 3-pin connector is for the 110/120 High Voltage input:



secured with cable strain reliefs.

FEED WIRES THROUGH STRAIN RELIEFS ON TOP HOUSING AS SHOWN. CONNECT WIRES USING WIRE NUTS, THEN RE-INSTALL TOP HOUSING WITH 4 SCREWS

H628 Data Hub The H628 Data Hub is used to connect each station to the Master Station.

Pull Wires Pull all the Door and Room Station cables to the location of the Master Station Mounting Bracket (VMC1MB).
If the installation consists of more than 5 room stations, Linear recommends using the optional Linear DMD-16 (16 stations) Data Distribution module and the Model H275 Universal Bracket (Optional, see Appendix A).

1 BROWN 2 WHITE/BROWN 3 GREEN 4 WHITE/GREEN 5 ORANGE

Radio Antennas VMC1 requires two antennas, one for AM and one for FM reception. The AM antenna is a 25-foot wire the FM antenna is a 25-foot length of coax with a “T” shaped wire dipole at one end that attaches between rafters in the attic.

Antenna arrangement is crucial to quality radio reception. AM and FM antennas should be placed at the highest point of the roof and at least six feet away from any electrical or intercom wiring.
✓IMPORTANT! Isolate the antenna leads from the intercom station cables
by running them through a separate hole in the ceiling plate. If grouped together, the intercom station cables can shield the antenna leads resulting in poor radio reception. Also keep the antenna leads away from metal duct work and aluminum backed insulation, which reduces reception.
on to the ‘open’ end of antenna with insulated wire. The gauge end of the wire should be strong enough to support it without breaking.
or vertical amplifi ed broadband antenna. Refer to those manufacturer’s installation instructions for further information.

Door Release Rough-in The Door Release Trigger can be activated from the VMC1 Master or any remote room station by pressing the Lock button. The Trigger will deactivate after 4 seconds and can be activated multiple times while the intercom is active.
Chime Activated Control Output Rough-In The Chime Activated Control Output allows for any number of security related automation functions including 10 available door chimes. To connect an auxiliary Chime refer to Figure 10. Refer to the hook-up instructions supplied with the chime.
To connect the optional Linear Model DRW Door Release Mechanism, refer to Figure 10 For controlling other door release devices, refer to the hook-up instructions supplied with the device.
MODEL DRW ELECTRONIC DOOR STRIKE
OR CHIME
VMC1VDS
GRAY
DOOR STATION
N/C NORMALLY CLOSED
BLUE
COMMON GREEN NORMALLY OPEN
BLUE
RED
WHITE
WHITE BLACK
MODEL 284 12V 5 AMP RELAY
USE WHITE WIRE FOR DOOR RELEASE USE BLACK WIRE FOR AUXILIARY CONTROL OUTPUT
MODEL RT11 OR RT35
PLUG-IN TRANSFORMER
Figure 10. Electric Door Strike Wiring

System Master Station with 5.6” TFT LED color screen supporting up to 20 remote stations. Point-to-Point, Point-to-Group and All Call

intercom with hands free response.
VMC1-BK (Black) VMC1-BZ (Bronze)

Color Video Door Station with 10 different door chimes, 90º horizontal and 50º degree vertical viewing angle. Standard
(VMC1VDS)
Color video door station with 10 door chimes, a

Bronze (pictured)(VMC1VDS-BZ)
Silver (VMC1VDS-S)

5 pack of alternative color room station faceplates VMC1RST-WH-5 White VMC1RST-AL-5 Almond (pictured)

security and automation functions
White (pictured)
(VMC1RS-WH)


one (1) Master, one (1) Alloy Door Station and
four (4) room stations
White(VMC1PACK)
Non-video door station. Basic doorbell intercom

weather resistance IP30
(VMC1DS-BZ Bronze) (VMC1DS-S Silver) pictured

use on a nightstand or desk
Black (VMC1TTS)

resistance of VMC1VDS to IP31 Smoke Color
(VDSWS-T)
Plexiglas weather shield increases the weather

Clear (DSWS)


Steel (VMC1MB)

Rough in kit for the VMC1 Master.

FM Dipole antenna, AM antenna wire and

(VMC1H)

except VMC1VDS
(VMC1HR Steel)

Data Hub Installation

(MLTL2DN49IR)


w/power supplies Remote Door Lock
(DRW)

12V Control Output switched 110V outlets for lights and other “notifi cation” devices
MFG: Xantec/Niles


(DXS-32)
Wire Relay The 284 Leaded Accessory Relay is a 5 amp

Form C relay with wire leads pre-attached.

door camera image to TV or get Video on TV
Single channel video modulator
(5415)
www.linearcorp.com

Linear LLC warrants these products to be free of defects for 2 years. The warranty period begins on either (a) the date of purchase or installation date of this product or (b) the date of closing on a new residence in which this product was originally installed. The warranty extends to the original user of the product and to each subsequent owner of the product during the term of the warranty. Linear LLC will repair or replace, at its option, parts and materials at no charge. Parts supplied under this warranty may be new or rebuilt at the option of Linear LLC.
ANY PRODUCT RETURNED TO LINEAR LLC WITHOUT A RPA NUMBER WILL BE REFUSED. This limited warranty is in lieu of any other warranties, express or implied, including any implied warranty of merchantability or fi tness for a particular purpose or otherwise, and of any other obligations or liability on the seller’s part. This limited warranty does not cover damage caused by improper installation, acts of God, criminal acts, the violation of applicable building or electrical codes or the use of non-recommended wire, cable (excluding Cat-5 and RG-6) or wall housings. Under no circumstances shall Linear LLC be liable for consequential, incidental or special damages arising in connection with use, or inability to use this product. In no event shall Linear LLC liability hereunder exceed the cost of the product covered hereby. No person is authorized to assume for us or obligate us for any other liability in connection with the sale of this product. Some states do not allow the exclusion or limitation of consequential, incidental or special damages, so the above limitation or exclusion may not apply to you. This limited warranty gives you specifi c legal rights, and you may also have other rights, which vary from state to state. This Linear LLC Warranty is in lieu of all other warranties express or implied.
If during the warranty period the product appears to have a defect, please call our toll free service number (800-421-1587) prior to dismantling. Dismantling the product prior to calling our service number may void the warranty. Before returning any product to Linear LLC, contact your local dealer or distributor. Linear LLC will return the repaired product freight prepaid within the continental United States. There are no obligations or liabilities on the part of Linear LLC for consequential damages arising out of or in connection with use or performance of this product or other indirect damages with respect to loss of property, revenue, or profi t, or cost of removal, installation, or reinstallation.
USA & Canada (800) 421-1587 & (800) 392-0123
(760) 438-7000 - Toll Free FAX (800) 468-1340
Copyright © 2012 Linear LLC 233254 AX3