As of date of manufacture, meets all ANSI/UL 325 Safety Requirements for Vehicular door operators.


Momentary Contact To Close: Standard operating mode. Requires a photo-beam as described above or one of the Miller Edge family of Door Edge devices as described on this page to be properly installed on the door and connected to the operator. See Page 12 for the entrapment protection installation guide. JACKSHAFT OPERATOR APPLICATIONS
The purpose of this booklet is to provide assembly, installation and operation information concerning Model AUJ-S & AUH-S Commercial Vehicular Garage Door Operators and related Accessory Products.
IT IS IMPORTANT THAT THIS INSTRUCTION MANUAL BE
Jackshaft operators are intended for commercial and industrial use to raise or lower sectional overhead doors by chain coupling or direct coupling to the door shaft. Jackshaft operators are suitable where all or part of the door remains in a vertical position when fully open such as doors with at least 18 inches of lift clearance or full vertical lift doors. Jackshaft operators may also be used with roll up service doors and grills when appropriately modified at the factory to obtain the correct speeds. A jackhaft operator DOES NOT LOCK THE DOOR IN ITS CLOSED POSITION. However, because the cross-header shaft is prevented by the operator from turning, the torsion springs provide no assistance in lifting the door should an attempt be made to raise it manually. The jackshaft operators as described in this manual are used in the following applications: - Continuous Duty, Medium Cycle Commercial
READ AND UNDERSTOOD COMPLETELY BEFORE INSTALLATION OR OPERATION IS ATTEMPTED. IT IS INTENDED THAT THE INSTALLATION OF THIS UNIT WILL
IN THE INSTALLATION, ADJUSTMENT AND SERVICE OF
COMMERCIAL OVERHEAD DOORS AND DOOR OPERATORS AND BY QUALIFIED ELECTRICIANS.
THE IMPORTANT SAFEGUARDS AND INSTRUCTIONS IN
THIS MANUAL CANNOT COVER ALL POSSIBLE CONDITIONS AND SITUATIONS WHICH MAY OCCUR
DURING ITS USE. IT MUST BE UNDERSTOOD THAT COMMON SENSE AND CAUTION MUST BE EXERCISED
BY THE PERSON(S) INSTALLING, MAINTAINING AND OPERATING THE EQUIPMENT DESCRIBED HEREIN. DO
NOT USE THIS EQUIPMENT FOR ANY OTHER THAN ITS
COMMERCIAL VEHICULAR GARAGE DOORS.
installations only - Indoor Use Only - Up to 24 foot high doors with a maximum area of 480
Solid State Controls: The openers employ solid state technology with advanced standard features to provide for a complete commercial door operating system.
square feet for 3/4 HP, 280 square feet for 1/2 HP and 200 square feet for 1/3 HP - maximum area slightly higher for lighter doors - consult factory - To operate in Momentary Contact To Close mode and comply with the UL325 Entrapment Protection requirements effective Aug. 29, 2010, the door system must include one of the following (a, b, or c): (a) Linear Corp. Photo-Beam System that consists of an emitter, Part No. 217792 and detector, Part No. 217800 for doors as described above up to 30 FT wide. See Page 13. (b) Any Miller Edge ME, MT/MU, and CPT family of edges, with suffix T2, must be connected to the SM-102 Edge Module, Recognized by UL as per UL325 2010 on 08-29- 2010 for door as described above. See Page 13. (c) A Vitector Fraba OSE 2-wire Photosystem as Recognized by UL as per UL325 2010 on 08-29-2010 for door as described above. See Page 13. - The manufacturer of this operator strongly recommends installation of one of the entrapment protection device above and states that one is REQUIRED where any automatic, remote or manual control is used to activate the door.
Switch Selectable Operating Modes: Six distinct base operation modes can be selected by resetting the switches on the motor control board: a standard Open, Close, Stop (B2, momentary button push); three constant pressure modes (C2, D1, and E2); two Timer to Close modes (T and TS). See page 17 for complete description of the modes.
Switch Selectable Characteristic Modes: Five different operating characteristics can be activated and/or modified through the switches on the motor control board: Delay On Reverse, Close Limit Delay, Mid Stop Travel, Timer to Close, Maximum Run Timer.
Limit Switches: Driven limit switches, easily adjusted over a wide range. The motor may be removed without affecting the limit switch adjustments
Manual Release: Permits manual operation of the door in the event of a power failure. The Model AUH-S is equipped with a chain hoist to aid in manual operation.
Control Circuit: Standard three button open, close and stop. 5 Volts DC.
Digital Radio Controls: Open, Close and Stop operation. Radio units are available to control up to 27 doors from one transmitter
Connections For Auxiliary Entrapment Protection Devices: For the ultimate in protection, terminals are provided to connect a Linear Corp. Photo-Beam System that consists of an emitter, Part No. 217792 and detector, Part No. 217800. This device when connected is a monitored photo-beam system. Additional connection terminals for a Normally Open and Normally Closed reversing devices such as a reversing door edge or a three wire photo-beam are provided.
Keyless Entry System: Connection terminals provided for hard wired or wireless keyless entry systems.
Direct Coupling (FS or FC Mount): Must be pre-ordered from the factory. Flange couplers direct connect the operator output shaft and the door shaft. Door shaft speed is 30 RPM unless otherwise specified.

verify that it is the correct model for the intended application and that the voltage and phase are in accordance with electrical power provided at the job site. If the operator was ordered with the optional chain hoist, ..H.. suffix, see that it is so equipped. A chain hoist CANNOT be added in the field.
PROPERLY COUNTERBALANCED AND PROPERLY ADJUSTED IN ACCORDANCE
INSTALLATION INSTRUCTIONS.
Before starting the installation of the operator, the door must be in good working condition and properly counterbalanced. Inspect the door and track for loose or missing hardware. Test the door manually for balance and ease of operation. Lubricate door hinges and rollers. If necessary, employ a qualified technician to adjust the springs for proper counterbalance of the door. Stops should be installed at the top end of each track to prevent the possibility of the door rollers moving beyond the ends of the track. If the cross header shaft is made from hollow tubing rather than solid rod, it is recommended that it be plugged with a short length of solid bar for a more secure installation of the shaft sprocket or flange coupler. Before removing the operator powerhead from the shipping carton, inspect the nameplate on the cover of the operator control box to
ADJUSTMENTS MUST BE MADE
ONLY BY A QUALIFIED PROFESSIONAL DOOR INSTALLER.
DEVICES FROM DOOR AND REMOVE
ALL ROPES


TO REDUCE THE RISK OF SEVERE INJURY OR DEATH: WARNING
READ AND FOLLOW ALL INSTALLATION INSTRUCTIONS!
Do not overtighten the clutch adjustment to compensate for a poorly working door.
Install the Entrapment Warning Placard next to the control station in a prominent location.
All warning signs and placards must be installed so they are visible in the area of the door.
After installing the opener, all safety features must be tested for proper operation (see page 22).
For products having a manual release, instruct the end user on the operation of the manual release.

SPRINGS, PULLEYS, CABLES AND MOUNTING HARDWARE USED TO BALANCE YOUR GARAGE DOOR ARE UNDER EXTREME TENSION AT ALL
TIMES AND CAN CAUSE SEVERE INJURY OR DEATH IF DISTURBED.
Figure 4, page 8 illustrates several positions suitable for mounting the operator; right hand or left hand, either wall mount or ceiling mount and center mount with direct coupling to the torsion shaft. Direct coupling may also be used in a side mount installation. Operators intended for direct coupling require an internal speed modification and must be ordered from the factory. CHAIN COUPLING MOUNTING Refer to Figure 2 (at right), Figure 1, page 4 and Figure 5, page 9 for component identification and the operator mounting slot locations. Place the sprockets [ 3 ] and [ 4 ] on the chosen side of the torsion shaft of the door and on the corresponding end of the output shaft of the operator. The sprockets should be kept as close as possible to the bearings. Fasten the connecting link to each end of the door chain and loop the chain over the sprocket [ 3 ] on the torsion shaft. Temporarily suspend the operator in its mounting position using the chain over the sprocket [ 4 ] at one end of the jackshaft and a rope or chain at the mid point (to support the operator weight). With the chain tight and straight and the jackshaft parallel with the torsion shaft, trace the mounting slot on the mounting surface then lower the operator to the floor. IT IS ESSENTIAL THAT THE SURFACE SUPPORTING THE OPERATOR BE RIGID AND SECURE. FAILURE TO PROVIDE A FIRM MOUNTING SURFACE WILL RESULT IN DAMAGE TO THE DOOR TORSION SHAFT AND THE PREMATURE FAILURE OF THE OPERATOR. If the construction permits, the operator should be mounted with 3/8 inch diameter bolts through the wall. If it is not feasible to go through the wall, then use lag bolts to fasten the operator to the mounting surface. Locate the four holes within the tracings of the slots made in the previous step at the positions which will allow for adjust-ment of the chain tension. After drilling the mounting holes and instal-ling lag shields, if necessary, bolt the operator to the mounting surface but do not completely tighten the bolts at this time. Check the alignment of the sprockets, adjust their positions on the shafts if necessary and tighten the set screws securely on both sprockets. pulling downward on the operator to remove slack from the chain, tighten the four mounting bolts. Inspect the installation. There should be no slack in the chain but neither should it be under severe tension which might shorten the life of the bearings. If there is any flexibility in the system due to
construction of the surface supporting the operator or noticeable deflection of the door shaft, it is advisable to install a shaft support between the operator jackshaft and the door shaft to prevent the loss of limit settings due to the possibility of the chain jumping over the sprocket teeth. Shaft supports are available from the factory. BEFORE PROCEEDING WITH THE OPERATOR INSTALLATION AND SETTINGS, MAKE A FINAL CHECK FOR TIGHTNESS OF ALL MOUNTING HARDWARE AND SET SCREWS. Proceed to “Chain Hoist and Floor Disconnect Installation”.

DIRECT COUPLING MOUNTING Figure 4, page 8 illustrates several positions suitable for mounting the operator including center mount with direct coupling to the torsion shaft. Direct coupling may also be used in a side mount installation. Operators intended for direct coupling require an internal speed modification and must be ordered from the factory. Refer to Figure 2, page 6 and Figure 5, page 9 and Figure 6, Page 10 for the location of the operator mounting holes. IT IS ESSENTIAL THAT THE OUTPUT SHAFT OF THE OPERATOR AND THE DOOR SHAFT BE CAREFULLY ALIGNED. MISALIGNMENT OF THE SHAFTS WILL CAUSE EXCESSIVE STRESS AND WEAR. Raise the operator to a position which brings the door and operator shafts into alignment and connect them together with the flange coupling supplied with operator. Support the other end of the operator jackshaft from the ceiling with a chain or rope. Holding the operator in a vertical position, carefully measure the distance from the operator mounting plates to the wall. Lower the operator to the floor and construct a secure mounting surface using the dimension measured in the previous step. Again raise the operator to its mounting position and re-connect the shafts. Mark the mounting slots in the support structure, drill and securely bolt the operator into place. BEFORE PROCEEDING WITH THE OPERATOR INSTALLATION AND SETTINGS, MAKE A FINAL CHECK FOR TIGHTNESS OF ALL MOUNTING HARDWARE.
CHAIN HOIST AND FLOOR DISCONNECT INSTALLATION If the operator is furnished with a chain hoist (Model AUH-S), pass the hand chain over the chain wheel and through the chain guides on the operator clutch shaft (opposite end from the large pulley). Fasten the ends of the chain together by opening and re-closing one link using two pairs of pliers. If the chain is too long (standard length for 16 foot high doors and below is 26 feet total length of chain), shorten it to the desired length using the method described above and discard the unused portion. Fasten the chain hoist holding bracket furnished with the operator to the wall approximately four feet from the floor. This bracket is also used to hold in place the release chain for both the chain hoist equipped units (Model AUH-S) and floor disconnect models (Model AUJ-S).





Figure 5 NOTE: Dimensions for Model AUJ-S are similar to above, Model AUJ-S is not provided with a chain hoist.



TO AVOID RISK OF ENTRAPMENT AND POSSIBLE DAMAGE TO THE DOOR AND OPERATOR THE LIMITS MUST BE ADJUSTED
OPERATOR.
SETTING THE LIMIT SWITCHES 1) With the cover open on the electrical enclosure, reference Figure 7 below. There are two (2) switches (A and B) mounted to the „V‟ bracket (F). The Close Limit switch (B) and the Open Limit switch (A) are mounted to the top side of the „V‟ bracket as shown. These switches are activated by the two limit nuts (E & C) on the threaded shaft which move laterally along the shaft as the operator opens and closes the door. When a limit nut nears the end of the shaft it activates a switch.
8) If needed, a fine adjustment of the Close Limit switch (B) or Open Limit switch (A) is possible by loosening the screws slightly that hold the switch to the V bracket and moving the switch within its mounting slots. Ensure to retighten the switch mounting screw. Moving the Reverse Cutout switch closer to the center of the box will increase the point where the reversing feature cuts out (to allow for irregularity in the floor, etc.). The reverse cutout point is factory adjusted to approx. 4 inches off the floor.
A
C D
B
A - OPEN LIMIT SWITCH B - CLOSE LIMIT SWITCH C - CLOSE LIMIT NUT D - LIMIT NUT RETAINING PLATE E - OPEN LIMIT NUT F - “V” BRACKET
F

DEATH. DISCONNECT POWER TO THE
OPENER BEFORE AND DURING INSTALLATION OF AN ACCESSORY
REVERSING DOOR EDGE OR PHOTOELECTRIC DEVICE. DO NOT RECONNECT POWER TO OPENER UNTIL INSTRUCTED TO DO SO. ENSURE DOORWAY
WARNING: The AUJ-S and AUH-S Series operators have been designed and constructed for use with voltages from 115 Volts AC to 480 Volts AC, in single or three phase. Check the operator nameplate label on the control box cover for the proper voltage and phase. The application of an improper input voltage or phase will result in catastrophic failure to the internal electrical components. Observe local electrical codes when wiring the operator. When hard wiring, observe state and local electrical codes. A wiring diagram is attached to the inside of the control box cover. Connect the appropriate voltage and phase power leads to the appropriate terminals as per the wiring diagram and connect a ground wire to the grounding screw. On three phase units, incorrect phasing of the power supply will cause the motor to rotate in the wrong direction (open when CLOSE button is pushed and vice versa). To correct this, interchange any two of the incoming three phase conductors. The wiring diagram attached inside the cover of the control box details all of the field wiring terminal connections for the operator. Always connect the wires to the push-button controls and auxiliary devices exactly as shown. Warning: Control voltage of the opener is 5 volts DC, Class 2. Do not run the power leads and control circuit wiring in the same electrical conduit.
Note: AUJ-S and AUH-S Series model operators are pre-wired for entrapment protection devices. To operate in Momentary Contact To Close mode and comply with the UL325 Entrapment Protection requirements effective Aug. 29, 2010, an approved external entrapment device as described on Page 3 must be installed and connected to the operator. Refer to Figure 8 and the manufacturer‟s instructions to install and connect one of the approved door edge devices. One or more contact sensors shall be located at the bottom edge of a vertically moving door. Refer to the instructions on Page 13 & 14 for the Linear photoelectric system installation and wiring. If the external entrapment protection device is connected, the selector switches are set properly (Page 17) and the device detects an obstruction or becomes inactive, an opening door continues to open and a closing door stops, pauses and starts open. While in this mode, if a problem is detected while the operator is stopped, a close will require constant activation of the control Close button. If an entrapment protection device as described above is attached and is properly working for 1 second, it will be auto detected and the monitored function will be turned on. Once the monitoring function is active, it will remain active even if the power is removed and the entrapment protection device is disconnected and power is restored. While in this mode, if a problem is detected while the operator is stopped, a close will require constant activation . Operators which have an operational entrapment protection device as described above may have one or more additional means of control which should be wired in accordance with the diagram supplied in the opener and also illustrated on Pages 23 & 24. To add a second three button station, refer to Figure 11. Number 22 gauge wire or heavier must be used for wiring the control stations and auxiliary control devices to the operator. Smaller gauge wire will cause operational problems, especially when multiple push-button stations are used or during summer months.
AND/OR DAMAGE TO DOOR OR PROPERTY,
ONLY OPERATE DOOR CONTROL WHEN
DOOR IS IN CLEAR VIEW. IF CONTROL STATION CANNOT BE LOCATED WHERE THE DOOR IS VISIBLE OR IF ANY OTHER DEVICE IS
ENTRAPMENT DEVICE (DOOR EDGE OR PHOTOELECTRIC) MUST BE CONNECTED.

Note: See the door edge manufacturer‟s installation instructions for the complete installation procedure. See Figure 9 for connecting the edge to the operator. See Page 17 for proper setting of the selector switches. These switches must be properly set and an approved photo- electric device or approved door edge device connected to the operator to obtain B2 Mode of Operation, Momentary Contact to Close.

DISABLED. USE AN INTERLOCK SWITCH IF A LOCK IS


Any Miller Edge ME, MT/MU, and CPT family of edges, must be connected to the SM-102 Edge Module, Recognized by UL as per UL325 2010 on 08-29-2010. See Note A to the left.
TB1
COM
24 VAC
ILOCK
SINGLE
COM
PHOTO
NC REV
NO REV
COM
STOP
CLOSE
OPEN
2 Wire Door Edge Protection Device wiring. Note: This device can be used for additional Entrapment protection but connection of this device will not enable the Momentary Contact to Open Mode.
Entrapment Protection Device See Note A above
3 Wire Photoelectric Entrapment Protection Device wiring. Note: This device can be used for additional Entrapment protection but connection of this device will not enable the Momentary Contact to Open Mode.
After properly connecting an approved Entrapment Protection Device (see above and Page 3) to the operator, see Page 17 for setting of the selector switches. These switches must be properly set and an approved photoelectric device or approved door edge device connected to the operator to obtain B2 Mode of Operation, Momentary Contact to Close.

D3
R5
R57
R65
R25
MOTOR CONTROL
RADIO
R84 R2
PCB 112695 REV B TSLK OPEN
D2
D8
U5
R3
COM
RM3
BOARD
U1
RM2
PB1 PB2 PB3
D12
RM1
BOARD
P7
STOP CLOSE OPEN
R38
R54
R87
U4
R26
R29
R30
R55
R94
R56
R95
R2
R3
PCB 112695 REV B TSLK OPEN
PB1 PB2 PB3
D12
PHOTO
NC REV
NO REV
COM
STOP
CLOSE
STOP CLOSE OPEN
NC REV
NO REV
COM
STOP
CLOSE
Single 3 Button Station
Multiple 3 Button Station Figure 11
c.p. ALLSTAR CORP
CDOMCB 2005
D1
MOTOR CONTROL
R8
R24
P5
BOARD
TB1
Single Button and External Interlock Wiring
COM
24 VAC
ILOCK
SINGLE
COM
PHOTO
TURNING ON THE POWER TO THE OPERATOR
NOTE: It is now necessary to turn on the power in order to change the Operating Mode (if applicable), program any changes desired to the operator’s other settings, check for proper performance of all the operator’s features to include the brake (if applicable) and clutch (adjusting settings if necessary); and to set and finalize any adjustments to the limit settings. Before doing so, ensure that all mounting hardware are installed and properly tightened, that all electrical connections are per local code requirements, and that proper wiring practices have been followed. Also, double-check that all ropes have been removed from the door and that the doorway is clear.

TO REDUCE THE RISK OF SEVERE INJURY OR DEATH: WARNING
READ AND FOLLOW ALL INSTRUCTIONS!
Understand all of the operating features of your door control system at the time of its installation. Your installing dealer will demonstrate them for you.
NEVER let children operate or play with door controls. Keep the Remote Control (where provided) away from children.
Personnel should keep away from a door in motion and keep the moving door in sight until the door is completely closed or opened. NO ONE SHOULD CROSS THE PATH OF A MOVING DOOR.
TEST THE DOOR OPENER’S SAFETY FEATURES AT LEAST ONCE A MONTH. After adjusting either the force setting or the limit of travel, ALWAYS RETEST the Operator’s safety features. Failure to ADJUST THE OPERATOR PROPERLY may cause SEVERE INJURY OR DEATH.
DO NOT over adjust the force setting to compensate for a poorly working door.
If possible, USE THE MANUAL RELEASE only when the door is closed. Use caution when using this release when the door is open. WEAK OR BROKEN SPRINGS MAY ALLOW THE DOOR TO CLOSE RAPIDLY, CAUSING SEVERE INJURY OR DEATH.
KEEP THE GARAGE DOOR PROPERLY BALANCED. See the door manufacturer’s owner's manual. An improperly balanced door COULD CAUSE SEVERE INJURY OR DEATH. Have a TRAINED DOOR SYSTEMS TECHNICIAN MAKE REPAIRS TO CABLES, SPRING ASSEMBLIES AND OTHER HARDWARE.
Inspect and maintain your door system as described in this manual.
AVOID ELECTROCUTION: DO NOT ROUTE LOW VOLTAGE WIRES IN
FAILURE TO TEST REVERSING SYSTEM COULD RESULT IN DEATH
SAME CONDUIT AS HIGH VOLTAGE
WIRES. FOLLOW ALL LOCAL ELECTRICAL CODES OR THE NATIONAL
OR SERIOUS INJURY. TEST THIS
SYSTEM ONCE A MONTH.
ELECTRICAL CODE.

Changing the Switch Selectable Operation Modes The following modes are selected by setting the on-board dip switches, Figure 20 at right shows where the switches are located on the operator control board. For each Operational Mode, the switches are set to either ON or OFF according to the table at right below. For all the modes, if an approved entrapment protection (EP) reversing device as described on page 3 of this manual is attached to the input labeled “Photo”, it will function as noted. Once an approved EP device is recognized by the control board it is monitored for correct operation. If the device becomes inactive then the mode will default to constant pressure activation for close regardless of the dip switch setting. In order for any of the Momentary Contact to Close operation modes (B2, TS, T) to become active an approved Entrapment Protection (EP) Reversing device (see Page 3) must be properly installed and connected to the operator. The switches must be set to one of the six Operational Mode combinations for the operator to function. In order for the NO (Normally Open) Reverse or NC (Normally Close) Reverse inputs to function, you must first install an operational approved Entrapment Protection (EP) Reversing Device. B2 Operation (Factory Default) Open Button: Momentary activation; open override of closing door. Close Button: Momentary activation. Stop Button: Momentary activation; stops open, close or reverse action. Single Button: Momentary activation to open; open override of closing door, closes door from mid-stop or open limit. EP Reverse (Photo Input): Momentary activation will reverse a closing door, reverse to full open (ignores mid-stop) unless stopped by stop pushbutton input. Mid-Stop: Activation stops an opening door; momentary contact of open button at mid stop will restart door to full open position; if door is moving open, constant pressure on open button will bypass mid-stop. Auto Close Timer: N/A. C2 Operation Open Button: Momentary activation; open override of closing door. Close Button: Constant activation, door will stop when button is released. Stop Button: Momentary activation; stops open, close or reverse action. Single Button: Momentary activation to open; open override of closing door. EP Reverse (Photo Input): Momentary activation will reverse a closing door, reverse to full open (ignores mid-stop) unless stopped by stop pushbutton input. Mid-Stop: Activation stops an opening door; momentary contact of open button at mid stop will restart door to full open position; if door is moving open, constant pressure on open button will bypass mid-stop. Auto Close Timer: N/A.
P4
Location
K2 K4 K3 K5 K6
HIGH VOLTAGE

TR3
COM
CLS
OLS
COM
MO4
MO3
POWER
STATUS
S4 S3 S2 S1
SW1
MO2
MO1
R89
R49
LD3 LD2 P2 P3
R10
R34
LD4
ILK
TR1
R62
R47
R22
R27 C16
R23
R33
R83
OFF
R53
COM
R51
R9
R28
R61
R46
R48 C13
TR2
R19
R17
R20
R18
R82
D3
R60
R5
R45
R57
R13
R1
R14
R21
R65
R25
RADIO
R52 C14
TR4
RO1
D2
D8
COM
R31
U1
RM3
EDGE
FRA
RM1
RM2
COM
S1
R85
R38
P7
R54
P6
R58
R16 R15
R11 R12
R87
U4
R26
R29
R30
R55
Q1
R7 R6
R94
R95
R56
c.p. ALLSTAR CORP.
R93
R90
U5
R84
R2
R3
PCB 112695 REV B TSLK
CDOMCB 2005
R8
R4
R24
PB1 PB2 PB3
D12
P5
TB1
STOP CLOSE OPEN
COM
24 VAC
ILOCK
SINGLE
COM
PHOTO
NC REV
NO REV
COM
STOP
CLOSE
OPEN
MOTOR CONTROL BOARD Figure 13
Operating Mode Switch 1 Switch 2 Switch 3 Switch 4
B2 Operation ON OFF OFF OFF
C2 Operation OFF
D1 Operation OFF ON OFF OFF
E2 Operation ON ON OFF OFF
TS Operation OFF OFF ON OFF
T Operation ON OFF ON OFF
D1 Operation Open Button: Constant activation; open override of closing door. Close Button: Constant activation, door will stop when button is released. Stop Button: Momentary activation; stops open, close or reverse action (not required). Single Button: N/A. EP Reverse (Photo Input): Momentary activation will stop a closing door. Mid-Stop: Activation stops an opening door; after the door stops at the mid stop, constant contact of open button at mid stop will restart door to full open position. Auto Close Timer: N/A. E2 Operation (roll-back) Open Button: Momentary activation; open override of closing door. Close Button: Constant activation, door will reverse to full open (ignores mid-stop) when button is released. Stop Button: Momentary activation; stops open, close or reverse action. Single Button: N/A. EP Reverse (Photo Input): Momentary activation to reverse a closing door, reverse to full open (ignores mid-stop) unless stopped by stop pushbutton input.

Mid-Stop: Activation stops an opening door; momentary contact of open button at mid stop will restart door to full open position; if door is moving open, constant pressure on open button will bypass mid-stop. Auto Close Timer: N/A TS Operation Open Button: Momentary activation; open override of closing door. Close Button: Momentary activation. Stop Button: Momentary activation; stops open, close or reverse action. Single Button: Momentary activation to open; open override of closing door, closes door from mid-stop or open limit. EP Reverse (Photo Input): Momentary activation will reverse a closing door, reverse to full open (ignores mid-stop) unless stopped by stop pushbutton input. Mid-Stop: Activation stops an opening door; momentary contact of open button at mid stop will restart door to full open position; if door is moving open, constant pressure on open button will bypass mid-stop. Auto Close Timer: Closes door from mid-stop or open limit after pre-set time. Stop will deactivate the auto close timer. Open will reactivate the auto close timer or reset the auto close timer when the door is at the mid-stop or open limit. Single button will reset the auto close timer from the mid-stop or open limit. Reverse
will reactivate the auto close timer or reset the auto close timer when the door is at the mid-stop or open limit. T Operation, Dip-Switch Setting Open Button: Momentary activation; open override of closing door. Close Button: Momentary activation. Stop Button: Momentary activation; stops open, close or reverse action. Single Button: Momentary activation to open; open override of closing door, closes door from mid-stop or open limit. EP Reverse (Photo Input): Momentary activation will reverse a closing door, reverse to full open (ignores mid-stop) unless stopped by stop pushbutton input. Mid-Stop: Activation stops an opening door; momentary contact of open button at mid stop will restart door to full open position; if door is moving open, constant pressure on open button will bypass mid-stop. Auto Close Timer: Closes door from mid-stop or open limit after pre-set time. Stop will deactivate the auto close timer. Open will reactivate the auto close timer or reset the auto close timer when the door is at the open limit. Single button will reset the auto close timer from the mid-stop or open limit. Reverse deactivates the auto close timer if the door is closing. Reverse will reset the auto close timer at the mid-stop or open limit if the auto close timer has not been previously deactivated.
Setup Modes Various operating characteristics can be modified via the setup modes. The operator is moved to the close limit position and the on-board dip switches (see Figure 13, page 17) are TEMPORARILY set according to the table at right to enter a Setup Mode. The on board OPEN and STOP buttons are used to modify the characteristic. Once set, the values are stored in non- volatile memory. These values are set to factory defaults that should be satisfactory for many applications. ALL VALUES AS DESCRIBED HERE CAN BE RESET TO THE FACTORY DEFAULTS AS FOLLOWS:
Delay on Reverse ON
Close Limit Delay OFF ON ON ON
Mid-Stop Limit ON OFF ON ON
Auto Close Timer OFF OFF ON ON
Remove 24 VAC power from the control board. Press and hold the on-board stop button. Re-apply 24 VAC while holding the on-board stop button. After completing the procedure to modify the operating characteristic the switches must be returned to the originally set Operating Mode setting (see section previous).
Changing the dip-switch setting to any other setting will save the new time. Return the dip switches to the originally set Operating Mode setting (see section previous).
Close Limit Delay Setup To provide for irregularities in the floor, this feature allows for the door to continue to travel down after the Reverse Cutout Limit is activated. The factory default time is 0.32 seconds; the minimum time is 0.12 seconds; the maximum time is 0.66 seconds.
Delay on Reverse Setup To help prevent stress on the door components, this feature allows for a delay time between the door stopping and reversing when a command to reverse is received as the door is closing. The factory default time is 0.75 seconds; the minimum time is 0.4 seconds; the maximum time is 2 seconds. After moving the door to the close position and temporarily setting the switches to the appropriate settings in the table, pressing STOP will reset the time to the minimum setting.
After moving the door to the close position and temporarily setting the switches to the appropriate settings in the table, pressing STOP will reset the time to the minimum setting.
Every time OPEN is pressed, 0.02 seconds are added to the time (up to the maximum).
Changing the dip-switch setting to any other setting will save the new time. Return the dip switches to the originally set Operating Mode setting (see section previous).
Every time OPEN is pressed, 200 mS is added to the time (up to the maximum).

Mid-Stop Limit Setup This features provides a timing function to stop a door as it is traveling open at a Mid Stop position instead of the full open position. The door can then be moved to the full open position if desired by pressing the Open button. A single button input when the door is at the mid stop position will cause the door to begin moving in the close direction. The factory default is not set; the minimum run time to mid-stop limit is 6 seconds.
After moving the door to the close position and temporarily setting the switches to the appropriate settings in the table, pressing STOP will clear and turn off the auto close timer.
Every time OPEN is pressed, 5 seconds is added to the time. Changing the dip-switch settings to any other settings will save the new time. Return the dip switches to the originally set Operating Mode setting (see section previous).
Maximum Run Time Setup This feature provides for a maximum amount of time the motor will be energized after an input is recognized. The factory default time is 30 seconds; the maximum time is 60 seconds.
After moving the door to the close position and temporarily setting the switches to the appropriate settings in the table, pressing STOP will remove the mid-stop limit setting.
Pressing OPEN will start the door open. When the door reaches the desired mid-stop position, press STOP.
After moving the door to the close position and temporarily setting the switches to the appropriate settings in the table, pressing STOP will reset the time to the factory default setting.
Changing the dip-switch setting to any other setting will save the mid-stop limit position. Return the dip switches to the originally set Operating Mode setting (see section previous).
Pressing OPEN will start the door open. The run time will be recorded when the door reaches the open limit. To prevent nuisance problems, 0.75 seconds are added to this time. Pressing stop before the door reaches the open limit will stop the door and reset the time to the factory default. Changing the dip-switch setting to any other setting will save the new time. Return the dip switches to the originally set Operating Mode setting (see section previous).
Auto Close Timer Setup This feature allows for a modification of the amount of time between the door reaching either the Mid Stop or the Full Open position and automatically starting in the close direction. The Auto Close feature is only active when the operator is set to the T or TS Operating Mode (see section previous). The factory default is 30 seconds; the minimum time is 5 seconds; the maximum time is 5 minutes.

The solenoid operated brake may require occasional adjustment. Adjustment is necessary if door tends to drift downward after reaching the open limit. Follow the instructions below and use Figure 14 as a guide. (1) Loosen shoe adjusting screw and bottom bracket arm of solenoid. (2) Move tab until drum has a slight drag. (3) Reverse drag slightly from tab and tighten shoe adjustment screw.

RUBBING AGAINST THE DOOR STOPS OR DEFECTIVE OR MISADJUSTED SPRINGS. ANY SERVICE REQUIRED TO THE DOOR, DOOR SPRINGS OR DOOR OPERATOR MUST BE PREFORMED BY A QUALIFIED PROFESSIONAL DOOR INSTALLER. The clutch pad will wear during normal operation and should be replaced when it becomes difficult or impossible to sufficiently tighten the clutch to obtain smooth operation of the door when it is in good working condition. To replace the clutch pad, first loosen the motor mounting bolts and remove the V-belt then the clutch adjusting nuts, spring and clutch pulley. Check condition of V-belt before reassembly and replace if required. After reassembly, adjust clutch as described above.
RISK OF ENTRAPMENT THAT MAY RESULT IN SERIOUS PERSONAL INJURY OR DEATH.
BEFORE SERVICING OR MAKING ADJUSTMENTS. ENSURE DOORWAY IS CLEAR BEFORE STARTING TESTING OF UNIT.
ADJUSTMENTS
The clutch serves to protect the door, the electric operator and other equipment from undue stress or damage caused by starting forces and/or an obstruction to the door. It should be set no tighter than is necessary to smoothly and consistently move the door throughout its full range of travel. When properly set, it will slip freely if the door should encounter an obstruction, and it should be possible to stop the travel of the door by hand. WARNING: Before adjustment remove power to the operator. To adjust the clutch, loosen the jamb nut, and turn the adjusting nut, as shown at right Make adjustments in 1/4 turn increments. Always re-tighten the jamb nut before running the operator to prevent clutch from changing its setting. CAUTION NEVER COMPRESS CLUTCH SPRING BEYOND POINT LIMITED BY THE DESIGN OF THE OPERATOR OR REPLACE IT WITH A HEAVIER SPRING Due to changing conditions of the door and normal wear, it may be necessary to occasionally readjust the clutch to obtain dependable operation. WARNING: BEFORE DOING SO BE CERTAIN THAT THE DOOR IS IN GOOD WORKING CONDITION, PROPERLY COUNTERBALANCED AND THAT THE CLUTCH IS NOT SLIPPING BECAUSE OF LOOSE OR MISSING HARDWARE, BINDING IN THE TRACK,
INJURY OR DEATH. SET CLUTCH ADJUSTMENT FOR JUST ENOUGH FORCE TO OPERATE THE DOOR RELIABLY, BUT NO STRONGER. Contact a service professional to correct any binding,
OVER-ADJUST CLUTCH SETTING TO COMPENSATE FOR A POORLY WORKING
DOOR.



Following installation, the operator MUST be tested and respond correctly to all controls as specified on the wiring diagram. KEEP personnel and equipment clear of the area beneath the door when performing the tests. When testing the 3 -button wall station, first observe that each button operates the door in the direction indicated and that the STOP button performs that function. With the door stopped at its full open position, the OPEN button should be inoperative. This should be verified and, likewise, the CLOSE button should be inoperative with the door fully closed. Certain operator control circuits use only a single button or a two button control station and may be designed to function differently than the more common three-button circuit described above. Test the controls in accordance with the description of operation as indicated on the wiring diagram and as selected on pages 17, 18, and 19, OPERATING and SET-UP MODES. Observe the door when traveling in each direction for smoothness of operation. Test the setting of the clutch by restraining the door by hand. The clutch should slip. Re-check the limit settings. The door should close tightly at the floor without excessive impact. Likewise, it should fully clear the door opening without the carrier striking the stops on the rail. The AUJ-S and AUH-S series operators are equipped with a reversing circuit and to allow for Momentary Close Contact operation an approved entrapment protection device as described on Page 3 needs to be properly installed and connected to the operator. To test it for proper reversal, place an object beneath the leading edge of the door. The door should instantly reverse when it comes into contact with the object provided the height of the object exceeds the cut out point built into the close limit switch (approximately four inches).
USE A CORRUGATED BOX OR OTHER SIMILAR OBJECT
If the operator is equipped with other means of control, such as additional 3 button stations or radio controls, each of these should be tested separately for proper operation. To test the manual disconnect first move the door to the fully closed position. Then disconnect the power to the operator. Manual door operation mode should engage when the release chain is pulled. The door can then be manually opened or closed by physically moving the door (Model AUJ-S) or using the hoist chain (Model AUH-S). If it is difficult to engage and/ or the jackshaft to doorshaft chain appears to be under compression, reset the CLOSE limit slightly to reduce the door travel in the close direction.
CONNECTING ACCESSORY DEVICES
OR MAKING ADJUSTMENTS.
Normally, very little maintenance is required. A monthly visual inspection must be made for loose or missing hardware and for excessive slack in the V-Belt and jackshaft chain. The clutch must be tested periodically and adjustments made if necessary (see page 20). The brake is adjusted at the factory and will need periodic adjustment for wear. When adjustment becomes necessary see Figure 14 on page 19 for the adjustment procedure. Test the reversing edge circuit at least once a month by permitting the door to contact an obstruction while closing.
OR OTHER SIMILAR OBJECT Lubrication of the operator is not required. It is important, for trouble free service from the operator, that the door be kept free from binding, properly counter balanced and periodically lubricated. An annual inspection of the door by a qualified overhead door professional is recommended. Warning: Repairs and adjustments to the door and operator should be performed only by someone qualified to service commercial overhead doors and operators.


OPERATING MODES SWITCH SETTINGS MODE S1 S2 S3 S4 C2 OFF B2 ON OFF OFF OFF D1 OFF ON OFF OFF E2 ON ON OFF OFF TS OFF OFF ON OFF T ON OFF ON OFF
Terminals “COM” and “PHOTO” - additional devices may be connected

MOTOR WIRING CHART CDO OPERATORS WITH CDO-MCB MOTOR CONTROL SYSTEM
A.O. SMITH SINGLE VOLTAGE - 115 VAC, 1P MOTOR

TO REVERSE MOTOR DIRECTION, SWITCH INCOMING LEADS TO TERMINALS 5 AND 8.
TO REVERSE MOTOR, SWITCH LEADS 3/4 & 2/1 TO REVERSE MOTOR, SWITCH LEADS L1 & L2
DUAL VOLTAGE MOTOR 208/230 VOLTS, 3 PHASE 460 VOLTS, 3 PHASE DUAL VOLTAGE MOTOR
ANY TWO INCOMING LEADS. TO REVERSE MOTOR DIRECTION, SWITCH
TO REVERSE MOTOR DIRECTION, SWITCH ANY TWO INCOMING LEADS.
TO REVERSE MOTOR DIRECTION, SWITCH ANY TWO INCOMING LEADS.
TO REVERSE MOTOR DIRECTION, SWITCH INCOMING LEADS TO TERMINALS 5 AND 8.


+CONNECTION SHOWN FOR 208 & 230V - FOR 460V SEE MOTOR DIAG. ON INSIDE OF CONT. BOX COVER
OPERATING MODES SWITCH SETTINGS MODE S1 S2 S3 S4 C2 OFF B2 ON OFF OFF OFF D1 OFF ON OFF OFF E2 ON ON OFF OFF TS OFF OFF ON OFF T ON OFF ON OFF
Terminals “COM” and “PHOTO” - additional devices may be connected

MOTOR WIRING CHART CDO OPERATORS WITH CDO-MCB MOTOR CONTROL SYSTEM
A.O. SMITH SINGLE VOLTAGE - 115 VAC, 1P MOTOR
TO REVERSE MOTOR DIRECTION, SWITCH INCOMING LEADS TO TERMINALS 5 AND 8.
TO REVERSE MOTOR, SWITCH LEADS 3/4 & 2/1 TO REVERSE MOTOR, SWITCH LEADS L1 & L2
DUAL VOLTAGE MOTOR 208/230 VOLTS, 3 PHASE 460 VOLTS, 3 PHASE DUAL VOLTAGE MOTOR
ANY TWO INCOMING LEADS. TO REVERSE MOTOR DIRECTION, SWITCH
TO REVERSE MOTOR DIRECTION, SWITCH ANY TWO INCOMING LEADS.
TO REVERSE MOTOR DIRECTION, SWITCH ANY TWO INCOMING LEADS.
TO REVERSE MOTOR DIRECTION, SWITCH INCOMING LEADS TO TERMINALS 5 AND 8.

1 009020 Shaft Collar, 3/4”
2 008071 Flange Bearing, 3/4”
A 109351 Frame Assembly w/Shafts. AUJ
3 106810 Pillow Block Bearing, 1”
109358 Frame Assembly w/Shafts, AUH
4 105549 Snap Ring, 3/4”
C 110076 Clutch Shaft Assembly, AUJ
5 100315 Hand Chain, AUH
110077 Clutch Shaft Assembly w/Hoist, AUH
6 106814 Sprocket, 65B10, 3/4” Bore, AUJ / H
7 106815 Sprocket, 65B27, 3/4” Bore, AUJ / H
E 109848 Secondary Shaft Assembly, AUJ / H (1/3 HP)
8 100210 Sprocket, 65B10, 3/4” Bore, AUJ Disconnect
109274 Secondary Shaft Assembly, AUJ / H (1/2 & 3/4 HP)
9 009070 Sprocket, 65B30, 1” Bore, AUJ / H (1/3 HP)
G 109273 Brake Assembly, AUJ / H, 115 VAC
10 100134 Sprocket, 41B10, 3/4” Bore, AUJ / H (1/2 & 3/4 HP)
109274 Brake Assembly, AUJ / H, 230 / 460 VAC
11 009062 Sprocket, 41B30, 1” Bore, AUJ / H (1/2 & 3/4 HP)
I CALL Control Box Assembly
12 009061 Drive Sprocket, 41B20, 1” Bore, AUJ / H (1/3 HP)
13 009062 Driven Sprocket, 41B30, 1” Bore, AUJ/H (1/3 HP)
K 100465 Motor, 1/3 HP, 48 ODP, 115 VAC, 1 PH
14 009057 Drive Sprocket, 40B20, 1” Bore, AUJ/H (1/2 & 3/4 HP)
100466 Motor, 1/2 HP, 48 ODP, 115 VAC, 1 PH
15 009136 Driven Sprocket, 40B30, 1” Bore, AUJ/H (1/2 & 3/4 HP)
005156 Motor, 1/3 HP, 56 ODP, 115/230 VAC, 1 PH
16 107144 Limit Chain, #65, 17” with Master Link
005026 Motor, 1/2 HP, 56 ODP, 115/230 VAC, 1 PH
17 009246 Secondary Chain, #40, 18”, AUJ
005027 Motor, 3/4 HP, 56 ODP, 115/230 VAC, 1 PH
009244 Secondary Chain, #41, 18”, AUH
19 009249 Primary Chain, #65, 24”, AUJ / H (1/3 HP)
30 009087 V Belt, 4L390
009242 Primary Chain, #41, 24”, AUJ / H (1/2 & 3/4 HP)
31 009155 Clutch Pulley w/Bushing, 4L
21 009239 Drive Chain, #41, 4’, AUJ / H, (1/3 HP)
32 009028 Clutch Fiber Disk
009240 Drive Chain, #40, 4’, AUJ / H, (1/2 & 3/4 HP)
33 100133 Clutch Plate
23 105385 Brake Solenoid, 115 VAC
34 105308 Clutch Spring
105386 Brake Solenoid, 230 VAC (also used on 460 VAC units)
35 100636 Clutch Lock Nut
25 110042 Brake Shoe
36 107517 Clutch Adjusting Nut
26 106806 Brake Drum w/4L Pulley, 5/8” Bore

MODEL : AUJ_ _ _ _S HP:_____
VOLTS : _____ PHASE : _____
* UL AND CANADIAN UL LISTED * HIGH STARTING TORQUE, CONTINUOUS DUTY MOTOR * MOTOR OVERLOAD PROTECTION * CLASS 2 (24 VOLT) CONTROL CIRCUIT * SOLENOID BRAKE * SOLID STATE MOTOR CONTROL CIRCUITRY WITH
* UL AND CANADIAN UL LISTED * HIGH STARTING TORQUE, CONTINUOUS DUTY MOTOR * MOTOR OVERLOAD PROTECTION * CLASS 2 (24 VOLT) CONTROL CIRCUIT * SOLENOID BRAKE * SOLID STATE MOTOR CONTROL CIRCUITRY WITH
ADVANCED OPERATIONAL FEATURES STANDARD
* THREE BUTTON CONTROL: OPEN, CLOSE, STOP
* THREE BUTTON CONTROL: OPEN, CLOSE, STOP
* WIRED TO ACCEPT REVERSING EDGE INPUT
* WIRED TO ACCEPT REVERSING EDGE INPUT
* HEAVY GAUGE, POWDER-COATED STEEL
* HEAVY GAUGE, POWDER-COATED STEEL FRAME
FRAME RAILS AND CONTROL BOX
RAILS AND CONTROL BOX
* ALL SPROCKETS AND PULLEYS PINNED OR KEYED,
* ALL SPROCKETS AND PULLEYS PINNED OR KEYED,
SOLID STEEL DRIVE SHAFTS
SOLID STEEL DRIVE SHAFTS
* FULLY ADJUSTABLE FRICTION CLUTCH * HEAVY DUTY PILLOW BLOCK BEARINGS ON OUTPUT SHAFT
* FULLY ADJUSTABLE FRICTION CLUTCH * HEAVY DUTY PILLOW BLOCK BEARINGS ON OUTPUT SHAFT
* FLOOR LEVEL DISCONNECT * FULLY ADJUSTABLE, INTERNAL, SHAFT DRIVEN LIMITS
* FULLY ADJUSTABLE, INTERNAL, SHAFT DRIVEN LIMITS ENGAGEMENT AND DISCONNECT.
LINEAR LIMITED WARRANTY This Linear product is warranted against defects in material and workmanship for 2 years. This warranty extends only to wholesale customers who buy direct from Linear or through Linear‟s normal distribution channels. Linear does not warrant this product to consumers. Consumers should inquire from their selling dealer as to the nature of the dealer‟s warranty, if any. There are no obligations or liabilities on the part of Linear LLC for consequential damages arising out of or in connection with use or performance of this product or other indirect damages with respect to loss of property, revenue, or profit, or cost of removal, installation, or reinstallation. All implied warranties, including implied warranties for merchantability and implied warranties for fitness, are valid only until the warranty expires. This Linear LLC Warranty is in lieu of all other warranties express or implied.
All products returned for warranty service require a Return Product Authorization Number (RPA#).
Contact Linear Technical Services at 1-800-421-1587 for an RPA# and other important details.
P/N 230769 REV X7 April 2011 Copyright © 2011 Linear LLC
Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.