Instruction/ maintenance manual of the product TopClean AS Johnson Pump
Go to page of 31
IM-AS/02.00 GB-JPAB (0412) Instruction Manual T opClean AS Hygienic, Self-priming Liquid Ring Pumps.
CE – Declaration of conformity Manufacturer Johnson Pump Box 1436 SE- 701 14 Örebro Sweden W e declare under our sole responsibility that the product: Pump Series AS CE declaration of conformity (Ann.
1 IM-AS/02.00 GB (0412) Index 1.0 Introduction ...................................................................................................... 3 2.0 Symbols .......................................................................................
2 IM-AS/02.00 GB (0412) 11.5.3.1 T execution .......................................................................... 14 11.5.3.2 V execution .......................................................................... 14 11.5.3.3 Q execution ........
3 IM-AS/02.00 GB (0412) To pClean Item No. r.p.m. kW Volt Hz Nastagatan 19, Örebro, Sweden · Tel +46 (0)19 21 83 00 Pump type Serial No. Name plate Warning : Pay great attention to the text parts indicated by this symbol. Danger : The non-observance of instructions can cause serious damage to persons and/or objects.
4 IM-AS/02.00 GB (0412) Before carrying out any operation which requires to disassembly of the pump (inspection, cleaning, seal replacement, etc.), the following preliminary operations have to be carried out: • Switch off engine tension and disinsert electric connection.
5 IM-AS/02.00 GB (0412) 5.0 Description The pumps of series AS are centrifugal side channel self-priming with star-shaped impeller; the ports are located on the longitudinal axe with the suction located on the front of the pump cover. All models have threaded connections for fittings according to DIN 11851 standard (unless otherwise requested).
6 IM-AS/02.00 GB (0412) Fig. 1 NO YES 6.0 Non-permitted uses Do not use the pump with a suction pressure greater than the specified value (0.5 times the discharge head generated by the pump). The pump must always be used in an environment appropriate to the level of protection of the motor.
7 IM-AS/02.00 GB (0412) 7.3 Electrical connection Make the electrical connection only after the hydraulic connection has been completed; set up the motor control system in conformity with the technica.
8 IM-AS/02.00 GB (0412) • The pump must always work smoothly and without vibrations. •D o not operate without liquid and in any case avoid prolonged operation with the discharge gate valve closed. • With series AS pumps never close discharge side completely.
9 IM-AS/02.00 GB (0412) 10.0 Seals All centrifugal pumps of the AS series are fitted with unified mechanical seals according to DIN 24960 - ISO 3069 standards, in order to grant the interchangeability (subject to verification of axial space). The type of mechanical seal and material are chosen according to the liquid to be pumped.
10 IM-AS/02.00 GB (0412) 11.0 Disassembly and Assembly AS-series 11.1 General instructions Assembly and disassembly may be preformed by qualified personnel only. Always wear appropriate safety clothing. Make sure that personnel are instructed and educated.
11 IM-AS/02.00 GB (0412) 4. Isolate and depressurize flushing/quench system. 5. Close the inlet and discharge valves. 6. Drain and purge the pump casing and pipe work.
12 IM-AS/02.00 GB (0412) 11.4.3 Seal disassembly 11.4.3.1 T execution 1. AS 42 and AS 52 only. Push back the ring retainer (31) to remove the circlip (32) from the shaft (4). 2. Remove the rotating seal half by turning the spring clockwise and at the same time pull the spring and the seal over the shaft end.
13 IM-AS/02.00 GB (0412) 11.4.4 Bearing removal 1. Remove shroud adapter (43) (if assembled) by loosening the screws (45). 2. Unscrew the screws (27). 3. Remove the bearing cover (8). 4. Press out the shaft and bearing assembly from the bearing housing (5).
14 IM-AS/02.00 GB (0412) 11.5.3.2 V execution 1. Press the radial seal (66) into the mechanical seal cover (65). 2. Fasten the stud bolt (68) on the pump casing (1). 3. Slide the mechanical seal cover (65) on the stud bolts (68) and tighten them. 4. Insert the stationary seal part into the pump casing (1) by gently pushing it.
15 IM-AS/02.00 GB (0412) 11.5.4 Assembly of pump casing and impeller assembly – AS 40, AS 50, AS 60, AS 65 and AS 80 1. Fit the correct clearance shims (19) (adjusted from pre-fitting) 2. Fit the impeller key (11) and push on the impeller (3). 3. Fit the O-ring (16) in the impeller nut (10) and tighten the impeller (3).
16 IM-AS/02.00 GB (0412) 11.5.5 Pump cover and Impeller assembly – AS 42 and AS 52 See drawing 1. Fit the first impeller key (11) and push on the impeller (3) on the shaft (4). 2. Fit the O-ring in the pump casing (1) groove and assemble the inter-suction casing (34).
17 IM-AS/02.00 GB (0412) 12.0 Spare parts lists and sectional drawings 12.1 Spare part list AS 40, 50, 60-65, 80 Pos Qty Description Material 11 Casing, pump CF-3M / 1.4409 1 Q 1 Casing, pump Q-execution CF-3M / 1.4409 1 V 1 Casing, pump V-execution CF-3M / 1.
18 IM-AS/02.00 GB (0412) 12.2 AS 40 – Execution T , Q, V 44 50 17 8 26 45 46 43 15 4 1 6 12 11 10 2 20 27 25 28 5 7 14 29 21 30 19 13 9 3 16 60 Q 61 Q 6 Q 1 Q 71 Q 68 Q 66 V 71 V 70 V 65 V 68 V 1 V .
19 IM-AS/02.00 GB (0412) 12.3 AS 50 – Execution T , Q, V 44 50 17 7 26 45 46 43 15 14 6 19 11 2 1 1 1 6 2 23 25 8 27 28 5 4 30 29 20 21 3 13 9 10 Execution T 62 Q 60 Q 6 Q 1 Q 61 Q 71 Q 66 V 71 V 65.
20 IM-AS/02.00 GB (0412) 12.4 AS 60-65 – Execution T , Q, V 44 50 17 7 28 45 46 43 15 14 1 6 12 16 2 25 23 23 25 8 27 26 5 4 30 29 20 21 19 3 13 9 11 10 Execution T 60 Q 71 Q 1 Q 61 Q 68 Q 6 Q 66 V .
21 IM-AS/02.00 GB (0412) 12.5 AS 80 – Execution T , Q, V 44 50 8 26 5 45 46 43 15 14 40 1 6 9 12 4 16 2 23 25 17 27 28 7 18 33 30 29 20 21 3 19 13 11 10 Execution T 61 Q 71 Q 6 Q 1 Q 60 Q 68 Q 87 V .
22 IM-AS/02.00 GB (0412) 12.6 Spare part list AS 42, 52 Pos. Q.ty Denomination Material 11 Casing, pump CF-3M / 1.4409 1 Q 1 Casing, pump Q-execution CF-3M / 1.4409 1 V 1 Casing, pump V -execution CF-3M / 1.4409 21 Cover , casing CF-3M / 1.4409 32 Impeller CF-3M / 1.
23 IM-AS/02.00 GB (0412) 12.7 AS 42 – Execution T , Q, V 50 17 8 7 26 45 46 43 15 14 1 13 34 35 36 3 11 2 25 44 23 28 27 5 29 21 20 30 31 32 4 38 39 6 60 Q 61 Q 6 Q 1 Q 71 Q 68 Q 66 V 71 V 70 V 65 V.
24 IM-AS/02.00 GB (0412) 12.8 AS 52 – Execution T , Q, V 44 50 17 7 26 45 46 43 15 14 6 32 1 31 3 34 35 36 11 2 23 25 8 27 28 5 4 30 29 20 21 31 38 39 62 Q 60 Q 6 Q 1 Q 61 Q 71 Q 66 V 71 V 65 V 1 V .
25 IM-AS/02.00 GB (0412) 13.0 Dimensions and weights 13.1 AS 40-50-60-65-80 with shroud 1450 rpm Dimensions not binding – DN = DIN 11851 male threaded connection – exec. with standar d IEC/EN motors 13.2 AS 40-50-60-65-80 without shroud 1450 rpm Dimensions not binding – DN = DIN 11851 male threaded connection – exec.
26 IM-AS/02.00 GB (0412) 13.3 AS 42-52 with shroud 1450 rpm Dimensions not binding – DN = DIN 11851 male threaded connection – exec. with standar d IEC/EN motors 13.4 AS 42-52 with shroud 1450 rpm Dimensions not binding – DN = DIN 11851 male threaded connection – exec.
27 IM-AS/02.00 GB (0412) 14.0 T rouble shooting chart The pump does not prime • Air has entered the suction piping; check the seals on the fittings and tighten them sufficiently. • Suction pipe not submerged in liquid. • Clearances between impeller/cover and impeller/body have increased.
28 IM-AS/02.00 GB (0412) 15.0 Disposal of the pump For disposing the pump please observe the following instructions: • Disconnect electrical and hydraulic connections according to technical rules and laws in force. • Disassemble all components of the pump for separate dismantling; wash the components and clean the structure accurately.
Johnson Pump Industry Group National Sales Organisations AUSTRALIA Johnson Pump (Australia) Pty . Ltd. T el. +61 (0)7 3899 9933 Fax +61 (0)7 3899 8574 BELGIUM Johnson Pump N.V ./S.A. T el. +32 (0)2 422 15 50 Fax +32 (0)2 422 15 59 DENMARK Johnson Pumper A/S T el.
An important point after buying a device Johnson Pump TopClean AS (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Johnson Pump TopClean AS yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Johnson Pump TopClean AS - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Johnson Pump TopClean AS you will learn all the available features of the product, as well as information on its operation. The information that you get Johnson Pump TopClean AS will certainly help you make a decision on the purchase.
If you already are a holder of Johnson Pump TopClean AS, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Johnson Pump TopClean AS.
However, one of the most important roles played by the user manual is to help in solving problems with Johnson Pump TopClean AS. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Johnson Pump TopClean AS along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center