Instruction/ maintenance manual of the product PH30F-XXX-XXX-C Ingersoll-Rand
Go to page of 8
INGERSOLL RAND COMP ANY L TD 209 NORTH MAIN STREET – BRY AN, OHIO 43506 (800) 276-4658 y F AX (800) 266-7016 © 2010 CCN 15307648 www.ingersollrandproducts.com OPERA T OR’S MANU AL PH30F-X XX - XX X -C INCL UDING: OPERA TION, INST ALLA TION & MAINTENANCE RELEASED: 5-28-08 REVISED: 11 -1 3 -10 (REV .
Page 2 of 8 PH30F-XX X-X XX-C (en) W ARNING EX CESSIVE AIR PRESSURE. Can cause per- sonal injury , pump damage or property damage. Do not ex ceed the maximum inlet air pressure as stated on the pump model plate . Be sure material hoses and other componen ts are able to withstand fluid pressures dev eloped by this pump .
PH30F-XX X-X XX-C (en) Page 3 of 8 y Hytrel® and V iton® are register ed trademarks of the DuPont Company y L octite® and 242® are registered trademarks of Henkel L octite Corporation y y Santoprene® is a regist ered trademark of Monsanto Company , licensed to Advanced Elastomer Sy stems, L.
Page 4 of 8 PH30F-XX X-X XX-C (en) P ARTS LIST / PH30F- XXX -X XX -C FLUID SECTION c 637441-X X Fluid Section S ervice Kits include: Balls (see Ball Option, refer to - XXX in chart below), Diaphragms .
PH30F-XX X-X XX-C (en) Page 5 of 8 ) ASSEMBL Y T ORQUE REQUIREMENTS ( NO TE: DO NOT OVERTIGHTEN F ASTENERS. ALL F ASTENERS ARE METRIC. (14) Cap screw , 65 - 70 ft lbs (88.1 - 94.9 Nm). (26) Manifold screw , 60 - 70 ft lbs (81.4 - 94.9 Nm). (27) Fluid cap screw , 60 - 70 ft lbs (81.
Page 6 of 8 PH30F-XX X-X XX-C (en) P ARTS LIST / PH30F- XXX -X XX -C AIR SEC TION d Indicates parts included in 637369 air sec tion service kit shown below and items 70, 144, 175 and 180 shown on page 4.
PH30F-XX X-X XX-C (en) Page 7 of 8 P ARTS LIST / PH30F- XXX -X XX -C AIR SEC TION ) ASSEMBL Y T ORQUE REQUIREMENTS ( NO TE: DO NOT OVERTIGHTEN F ASTENERS. ALL F ASTENERS ARE METRIC. (105) Screw , 15 - 20 in. lbs (1.7 - 2.3 Nm). (134) Screw , 40 - 50 in.
Page 8 of 8 PH30F-XX X-X XX-C (en) PN 97999-1381 TROUBLE SHOO TING Product discharged from e xhaust outlet. Check for diaphragm ruptur e. Check tightness of (14) cap screw . Air bubbles in product discharge. Check connections of suction plumbing. Check “O” rings between intake manifold and uid caps.
An important point after buying a device Ingersoll-Rand PH30F-XXX-XXX-C (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Ingersoll-Rand PH30F-XXX-XXX-C yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Ingersoll-Rand PH30F-XXX-XXX-C - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Ingersoll-Rand PH30F-XXX-XXX-C you will learn all the available features of the product, as well as information on its operation. The information that you get Ingersoll-Rand PH30F-XXX-XXX-C will certainly help you make a decision on the purchase.
If you already are a holder of Ingersoll-Rand PH30F-XXX-XXX-C, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Ingersoll-Rand PH30F-XXX-XXX-C.
However, one of the most important roles played by the user manual is to help in solving problems with Ingersoll-Rand PH30F-XXX-XXX-C. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Ingersoll-Rand PH30F-XXX-XXX-C along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center