INGERSOLL RAND COMP ANY L TD 209 NORTH MAIN STREET – BRY AN, OHIO 43506 (800) 495-0276 F AX (800) 892-6276 © 2012 CCN 46750519 www.ingersollrandproducts.c om OPERA T OR’S M ANU AL PH15F- X X X - XX X -X INCL UDING: OPERA TION, INST ALLA TION & MAINTENANCE RELEASED: 12-14-12 (REV .
Page 2 of 8 PH15F-X XX- XX X- X (en) W ARNING EX CESSIVE AIR PRESSURE. Can cause per- sonal injury , pump damage or property damage. Do not exc eed the maximum inlet air pressure as stated on the pump model plat e. Be sure material hoses and other components are able to withstand fluid pressures developed b y this pump.
PH15F-X XX- XX X- X (en) Page 3 of 8 Hytrel® and Viton® are r egistered trademarks of the DuP ont Compan y Loctite® and 242® are regist ered trademarks of Henkel Loctite Corporation Santoprene® is a regist ered trademark of Monsanto Compan y , licensed to Advanced Elast omer Systems, L.
Page 4 of 8 PH15F-X XX- XX X- X (en) P ARTS LIST / PH15F- XX X - XX X- X FL UID SEC TION 637445- XX Flu id Section Service Kits include: Balls (see Ball Option, ref er to -XX X in char t below ), .
PH15F-X XX- XX X- X (en) Page 5 of 8 15 181 70 1 68 26 144 175 43 78 27 131 180 21 21 19 22 61 26 78 60 63 60 5 69 195 19 70 144 126 � 77 77 76 15a 76 9 14 29 26 6 8 19 19 (models PH15F-AXX-XXX and PH15F-BXX-XXX) (model PH15F-FXX-XXX) 2 61 (model PH15F-FXX-XXX) ASSEMBL Y T ORQUE REQUIREMENTS NO TE: DO NO T OVERTIGHTEN F ASTENERS.
Page 6 of 8 PH15F-X XX- XX X- X (en) P ARTS LIST / PH15F- XX X - XX X- X AIR SECTION Indicates parts included in 637389 air section ser vice kit shown below and items 70, 144, 175 and 180 shown on page 4.
PH15F-X XX- XX X- X (en) Page 7 of 8 P ARTS LIST / PH15F- XX X - XX X- X AIR SECTION ASSEMBL Y T ORQUE REQUIREMENTS NO TE: DO NO T OVERTIGHTEN F ASTENERS. ALL F ASTENERS ARE METRIC. T orque (105 and 134) screw s to 35 - 40 in. lbs (4.0 - 4.5 Nm).
Page 8 of 8 PH15F-X XX- XX X- X (en) PN 97999-1647 TROUBLE SHOO TING Product discharged from e xhaust outlet. Check for diaphrag m rupture. Check tightness of (14) cap screw . Air bubbles in product discharge. Check connections of suction plumbing. Check “O” rings between intake manifold and uid caps .
An important point after buying a device Ingersoll-Rand PH15F-XXX-XXX-X (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Ingersoll-Rand PH15F-XXX-XXX-X yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Ingersoll-Rand PH15F-XXX-XXX-X - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Ingersoll-Rand PH15F-XXX-XXX-X you will learn all the available features of the product, as well as information on its operation. The information that you get Ingersoll-Rand PH15F-XXX-XXX-X will certainly help you make a decision on the purchase.
If you already are a holder of Ingersoll-Rand PH15F-XXX-XXX-X, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Ingersoll-Rand PH15F-XXX-XXX-X.
However, one of the most important roles played by the user manual is to help in solving problems with Ingersoll-Rand PH15F-XXX-XXX-X. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Ingersoll-Rand PH15F-XXX-XXX-X along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center