Instruction/ maintenance manual of the product PH10A-X-X Ingersoll-Rand
Go to page of 8
E 2010 CCN 99755480 (800) 276-4658 D F AX (800) 266-7016 INGERSOLL RAND COMP ANY L TD 209 NORTH MAIN STREET - - BRY AN, OHIO 43506 OPERA T OR’S MANUAL P H 1 0 A -X -X RE LE ASE D: 7 -7 -00 REVISED: 10-15-10 (REV .
PH10A-XXX-XXX (en) Page 2 of 8 OPERA TING AND SAFETY PRECAUTIONS READ, UNDERST AND, AND FOLLOW THIS INFORMA TION TO A VOID INJURY AND PROPERTY DAMAGE. EXCESSIVE INLET AIR PRESSURE ST A TIC SPARK EXPLOSION HAZARD HAZARDOUS MA TERIALS HAZARDOUS PRESSURE INJECTION HAZARD W ARNING EXCESSIVE AIR PRESSURE.
Page 3 of 8 PH10A-XXX-XXX (en) GENERAL DESCRIPTION The 1” metallic diaphragm pump offers high volume delivery even at low air pressures, easy self priming, the ability to pump various viscosity ma- terials and the ability to pass solids (as stated in the chart above).
PH10A-XXX-XXX (en) Page 4 of 8 P ARTS LIST / PH10A -XXX-XXX FLUID SECTION FLUID SECTION P ARTS Item Description (size) Qty Part No. [Mtl] L Fluid Section Service Kit 637339-( ) V 1 Rod (1) 98724-1 [C] n 2 “O” Ring (3/32” x 3/4” o.d.) (1) Y330-1 13 [B] L 3 “O” Ring (3/32” x 11/16” o.
Page 5 of 8 PH10A-XXX-XXX (en) P ARTS LIST / PH10A -XXX-XXX FLUID SECTION . TORQUE REQUIREMENTS , NOTE: DO NOT OVERTIGHTEN F ASTENERS. (14) Bolt, 49 - 52 ft lbs (66.4 - 70.5 Nm). (26) Bolts, 120 - 140 in. lbs (13.6 - 15.8 Nm). (29) Flange nuts, 280 - 300 in.
PH10A-XXX-XXX (en) Page 6 of 8 P ARTS LIST / PH10A -XXX-XXX AIR MOT OR SECTION n Indicates parts included in 637338 Air Section Repair Kit. Item Description (size) Qty Part No. Mtl Item Description (size) Qty Part No. Mtl 101 Motor Center Body (1) 95122 -1 [A] n 102 “O” Ring (1/16” x 1” o.
Page 7 of 8 PH10A-XXX-XXX (en) P ARTS LIST / PH10A -XXX-XXX AIR MOT OR SECTION Figure 3 127 201 l 126 109 j 111 102 jm 103 11 8 137 j 136 109 121 MAJOR V AL VE See cross section detail figure 4.
PH10A-XXX-XXX (en) Page 8 of 8 TROUBLE SHOOTING Product discharged from exhaust outlet. S Check for diaphragm rupture. S Check tightness of bolt (14). Air bubbles in product discharge. S Check connections of suction plumbing. S Check “O” rings between intake manifold and fluid caps.
An important point after buying a device Ingersoll-Rand PH10A-X-X (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Ingersoll-Rand PH10A-X-X yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Ingersoll-Rand PH10A-X-X - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Ingersoll-Rand PH10A-X-X you will learn all the available features of the product, as well as information on its operation. The information that you get Ingersoll-Rand PH10A-X-X will certainly help you make a decision on the purchase.
If you already are a holder of Ingersoll-Rand PH10A-X-X, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Ingersoll-Rand PH10A-X-X.
However, one of the most important roles played by the user manual is to help in solving problems with Ingersoll-Rand PH10A-X-X. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Ingersoll-Rand PH10A-X-X along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center