E 2010 CCN 15197213 (800) 495-0276 D F AX (800) 892-6276 INGERSOLL RAND COMP ANY L TD 209 NORTH MAIN STREET - - BRY AN, OHIO 43506 1 - 1/2” DIAPHRAGM PUMP OPERA T OR’S MANUAL PD15X - XXX - XXX RE LE A SE D: 8 -7 -0 3 REVISED: 5-12-10 (REV .
PD15X-XXX-XXX (en) Page 2 of 8 OPERA TING AND SAFETY PRECAUTIONS READ, UNDERST AND, AND FOLLOW THIS INFORMA TION TO A VOID INJURY AND PROPERTY DAMAGE. EXCESSIVE AIR PRESSURE ST A TIC SPARK HAZARDOUS MA TERIALS HAZARDOUS PRESSURE W ARNING EXCESSIVE AIR PRESSURE.
Page 3 of 8 PD15X -XXX-XXX ( en) GENERAL DESCRIPTION The ARO diaphragm pump offers high volume delivery even at low air pressure and a broad range of material compatibility options available. Refer to the model and option chart. ARO pumps feature stall resistant design, modular air motor / fluid sections.
MA TERIAL CODE [A] = Aluminum [B] = Nitrile [C] = Carbon Steel [CI] = Cast Iron [Co] = Copper [E] = E.P .R. [H] = Hytrel [Ha] = Hastelloy-C [K] = Kynar R PVDF [MSp] = M edical Grade Santoprene [P] = P.
Page 5 of 8 PD15X -XXX-XXX ( en) P ARTS LIST / PX15X -XXX-XXX FLUID SECTION COLOR CODE 15 FOR THE AIR MOTOR SECTION SEE P AGES 6 & 7 Santoprene 8 PTFE 7 131 , x 175 k Figure 2 View of two piece PTFE diaphragm 29 , 144 k 70 k . TORQUE REQUIREMENTS , NOTE: DO NOT OVERTIGHTEN F ASTENERS.
PD15X-XXX-XXX (en) Page 6 of 8 P ARTS LIST / PX15X -XXX-XXX AIR SECTION n Indicates parts included in 637389 Air Section Service Kit shown below and items (70), (144), (175) and (180) shown on page 4. AIR MOTOR P ARTS Item Description (size) Qty Part No.
Page 7 of 8 PD15X -XXX-XXX ( en) P ARTS LIST / PX15X -XXX-XXX AIR SECTION 168 k . TORQUE REQUIREMENTS , NOTE: DO NOT OVERTIGHTEN F ASTENERS. ALL F ASTENERS ARE METRIC. PX15A -XXX-XXX and PX15S -XXX-XXX: T orque (105 and 134) screws to 40 - 50 in. lbs (4.
PD15X-XXX-XXX (en) Page 8 of 8 TROUBLE SHOOTING Product discharged from exhaust outlet. S Check for diaphragm rupture. S Check tightness of (14) diaphragm screw . Air bubbles in product discharge. S Check connections of suction plumbing. S Check “O” rings between intake manifold and inlet side fluid caps.
An important point after buying a device Ingersoll-Rand PD15X-XXX-XXX (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Ingersoll-Rand PD15X-XXX-XXX yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Ingersoll-Rand PD15X-XXX-XXX - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Ingersoll-Rand PD15X-XXX-XXX you will learn all the available features of the product, as well as information on its operation. The information that you get Ingersoll-Rand PD15X-XXX-XXX will certainly help you make a decision on the purchase.
If you already are a holder of Ingersoll-Rand PD15X-XXX-XXX, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Ingersoll-Rand PD15X-XXX-XXX.
However, one of the most important roles played by the user manual is to help in solving problems with Ingersoll-Rand PD15X-XXX-XXX. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Ingersoll-Rand PD15X-XXX-XXX along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center