Instruction/ maintenance manual of the product PD05P-XXX-XXX Ingersoll-Rand
Go to page of 8
CCN 99713398 OPERA T OR’S MANU AL PD05P - X X X -X X X INCL UDING: OPERA TION, INST ALLA TION & MAINTENANCE RELEASED: 5-15-98 REVISED: 11-12-10 (REV . J) 1/2" DIAPHRA GM PUMP 1:1 RA TIO (MET ALLIC) READ THIS MANUAL CAREFULL Y BEFORE INST ALLING, OPERA TING OR SERVICING THIS EQUIPMENT .
Page 2 of 8 PD05P-X XX- XXX (en) W ARNING EX CESSIVE AIR PRESSURE. C an cause per- sonal injury , pump damage or property damage. Do not ex ceed the maximum inlet air pr essure as stated on the pump model plate . Be sure material hoses and other componen ts are able to withstand fluid pressures dev eloped by this pump .
PD05P-X XX- XXX (en) Page 3 of 8 OPERA TING INSTRUCTIONS Always flush the pump with a solvent c ompatible with the material being pumped if the material being pumped is subject to “setting up ” when not in use for a period of time. Disconnect the air supply from the pump if it is to be in- active for a few hours .
Page 4 of 8 PD05P-X XX- XXX (en) P ARTS LIST / PD05P- XX X- XX X FL UID SEC TION 637140-X X Fluid Section Ser vic e Kits include: Balls (see Ball Option, refer to - XX in chart below), Diaphragms (see Diaphragm O p- tion, refer to - XX in chart below), and items 2 and 19 (listed below) plus 93706-1 K ey-Lube gr ease packet (page 6).
PD05P-X XX- XXX (en) Page 5 of 8 19 62 15 22 22 12 21 12 21 19 61 (models PD05P-AAS- XX X) 26 61 (models PD05P-ASS- XX X) 43 26 60 (models PD05P-ASS- XX X) 63 .
Page 6 of 8 PD05P-X XX- XXX (en) P ARTS LIST / PD05P- XX X- XX X AIR MO TOR SECTION 9 Indicates par ts included in 637141 air sec tion repair kit. MA TERIAL CODE [B] = Nitrile [D] = Acetal [SY ] = Syn.
PD05P-X XX- XXX (en) Page 7 of 8 P ARTS LIST / PD05P- XX X- XX X AIR MO TOR SECTION ) T ORQUE REQUIREMENTS ( NO TE: DO NOT O VERTIGHTEN F ASTENERS. (134) T orque to 15 - 20 in. lbs (1.7 - 2.3 Nm), wait 10 minutes, then re-torque to 15 - 20 in. lbs (1.
Page 8 of 8 PD05P-X XX- XXX (en) PN 97999-781 TROUBLE SHOO TING Product discharged from air e xhaust. Check for diaphragm ruptur e. Check tightness of (14) bolt. Air bubbles in product discharge. Check connections of suction plumbing. Check “O” rings between intake manifold and uid caps.
An important point after buying a device Ingersoll-Rand PD05P-XXX-XXX (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Ingersoll-Rand PD05P-XXX-XXX yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Ingersoll-Rand PD05P-XXX-XXX - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Ingersoll-Rand PD05P-XXX-XXX you will learn all the available features of the product, as well as information on its operation. The information that you get Ingersoll-Rand PD05P-XXX-XXX will certainly help you make a decision on the purchase.
If you already are a holder of Ingersoll-Rand PD05P-XXX-XXX, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Ingersoll-Rand PD05P-XXX-XXX.
However, one of the most important roles played by the user manual is to help in solving problems with Ingersoll-Rand PD05P-XXX-XXX. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Ingersoll-Rand PD05P-XXX-XXX along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center