Instruction/ maintenance manual of the product 66610X-X-C Ingersoll-Rand
Go to page of 8
E 2006 CCN 81376642 & (800) 276-4658 D F AX (800) 266-7016 INGERSOLL RAND COMP ANY LT D P .O. BOX 151 D ONE ARO CENTER D BRY AN, OHIO 43506-0151 OPERA T OR’S MANUAL 66610X-X-C RELEASED: 8-24-89 REVISED: 5-25-06 (REV .
66610X-X-C Page 2 of 8 OPERA TING AND SAFETY PRECAUTIONS READ, UNDERST AND, AND FOLLOW THIS INFORMA TION TO A VOID INJURY AND PROPERTY DAMAGE . EXCESSIVE AIR PRESSURE ST ATIC SP ARK HAZARDOUS MA TERIALS HAZARDOUS PRESSURE W ARNING EXCESSIVE AIR PRESSURE.
Page 3 of 8 66610X-X-C GENERAL DESCRIPTION The ARO diaphragm pump offers high volume delivery even at low air pressure and a broad range of material compatibility options available. Refer to the model and option chart. ARO pumps feature stall resistant design, modular air motor / fluid sections.
MA TERIAL CODE [A] = Aluminum [B] = Nitrile [C] = Carbon Steel [CI] = Cast Iron [Co] = Copper [D] = Acetal [E] = E.P .R. [H] = Hytrel [K] = P .V .D.F .
Page 5 of 8 66610X-X-C P ARTS LIST / 66610X-X-C FLUID SECTION 2 k d 5 7 8 9 14 , z 15 16 18 19 k 21 22 24 29 , 21 22 FOR THE AIR MOTOR SECTION SEE P AGES 6 & 7 View for -X44 (T eflon diaphragm) configuration only . d NOTE: Radius edge of parts (5 and 6) is against diaphragm.
66610X-X-C Page 6 of 8 P ARTS LIST / 66610X-X-C AIR MOTOR SECTION n Indicates parts included in 6371 18-C Air Section Service Kit. SER VICE KIT NOTE: Service Kit 6371 18-C is a general repair kit for all 1" and larger ARO diaphragm pump air motors.
Page 7 of 8 66610X-X-C P ARTS LIST / 66610X-X-C AIR MOTOR SECTION MAJOR V AL VE See cross section detail, figure 4. PILOT V AL VE 101 1 18 k 111 11 2 k 11 3 k 11 4 11 5 11 6 11 7 1 19 k 103 k 104 123 H 121 122 k 120 107 108 109 1 10 k 106 .
66610X-X-C Page 8 of 8 TROUBLE SHOOTING Product discharged from exhaust outlet. S Check for diaphragm rupture. S Check tightness of (14) diaphragm screw . Air bubbles in product discharge. S Check connections of suction plumbing. S Check O" rings between intake manifold and fluid caps.
An important point after buying a device Ingersoll-Rand 66610X-X-C (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Ingersoll-Rand 66610X-X-C yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Ingersoll-Rand 66610X-X-C - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Ingersoll-Rand 66610X-X-C you will learn all the available features of the product, as well as information on its operation. The information that you get Ingersoll-Rand 66610X-X-C will certainly help you make a decision on the purchase.
If you already are a holder of Ingersoll-Rand 66610X-X-C, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Ingersoll-Rand 66610X-X-C.
However, one of the most important roles played by the user manual is to help in solving problems with Ingersoll-Rand 66610X-X-C. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Ingersoll-Rand 66610X-X-C along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center