Owner’s Manual SUBMERSIBLE PUMP WSP50 l WSPlOO I I I I I I I I I I I I I I I I I I I I I I i i i i i i i i i i i i i i i i i i i i i I.
.
USE AND MAINTENANCE INSTRUCTIONS MANUAL 1.1 MANUFACTURER DATA EBARA INTERNATIONAL CORPORATION 1651 CEDAR LINE DRIVE ROCK HILL, SC 29730 1.2 PUMP DATA Description: SUBMERSIBLE SOLIDS PUMP Model: WSP5OAM, WSP50AA, WSPI OOAM, WSPI OOAA Year of manufacture: see plate on the pump.
7. TECHNICAL DATA CARD 7.1. Pump technical data 7.2. Motor technical data 8. RECOMMENDED AND NON-RECOMMENDED USES 8.1. Recommended conditions of use 8.2. Non-recommended conditions of use 9. HANDLING AND TRANSPORT 9.1. Unpacking 9.2. Handling and disconnecting 9.
FAILURE TO OBSERVE THESE WARNINGS AND /OR TAMPERING WITH THE PUMP RELIEVES THE MANUFACTURER OF ANY RESPONSIBILITY IN THE EVENT OF DAMAGE TO PERSONS OR OBJECTS AND/OR TO THE PUMP.
6.1 GENERAL DESCRIPTION WSPSO and WSPl 00 series pumps are all similar from the functional and constructive point of view; the only differences are the following: -power -flow rate -head -weight -dimensions WSP50 and WSPlOO series pumps are used for handling water, even at high temperatures (chapter 7.
7.2. MOTOR TECHNICAL DATA WSP5O/WSPlOO Power (Versions) l/2 hp 7 hp 7% Poles Insulation class Degree of protection Type of duty Phase-frequency-voltage Overload protection Motor structure material Shaft material Cable material THE MANUFACTURER RESERVES THE RIGHT TO ALTER THE TECHNICAL DATA IN ORDER TO MAKE IMPROVEMENTS AND BRING THEM UP-TO- DATE.
9.1. UNPACKING Check that there are no breaks or severe dents in the packing; if there are, point this out immediately to the person who delivers the material. After removing the pump from the package, check that it has not suffered any dam- age during transport; if damage is found, inform the dealer within 8 days of delivery.
-ITO LIFT OR LOWER THE PUMP, USE A ROPE FIXED TO THE HANDLE; NEVER USE THE ELECTRIC POWER CABLE. 70.1. FIXED INSTALLATION a) The pump must be placed on a level surface. b) Lower the pump with a cable fixed to the handle. c) When positioning the pump, observe the minimum required distancesGig.
b) The outlet must have an efficient ground system complying with the electrical standards in force in the user’s country; the installer is responsible for checking this. c) The WSPSO and WSPlOO pumps have a plug with ground contact; ground- ing is provided by the plug itself when it is inserted in the socket.
a) If the intake mouth is blocked it must be cleaned; always wear gloves to protect your hands. b) If the impeller is dirty proceed as follows (fig. 4): -wear protective gloves to avoid cutting your h.
TYPE OF FAULT The pump stops after brief periods of operation (tripping of the thermal protection) CAUSE REMEDY Impeller blocked by foreign bodies. Remove the foreign bodies (ch. 74). Be certain to disconnect power. Liquid temperature too high. The temperature exceeds the technical limits of the pump.
15.1. DIAGRAM FOR INSTALLATION WITH MINIMUM FUNCTIONAL SPACES (fig. 1) 11.
15.2. WIRING DIAGRAM WSP50AA AND WSPIOOAA (fig. 2) 15.3. WIRING DIAGRAM FOR WSP50AM AND WSPlOOAM (fig. 3) 1 115v 1 Bmm, 2 Q I Main I Auxl I , 12.
15.4. DIAGRAM FOR PUMP IMPELLER COVER DISASSEMBLY (fig. 4) 13.
Honda Power Equipment dealership personnel are trained professionals. They should be able to answer any question you may have. If you encounter a problem that your dealer does not solve to your satisfaction, please discuss it with the deal- ership’s management.
Current customer service contact information: United States, Puerto Rico, and U.S. Virgin Islands: Honda Power Equipment dealership personnel are trained professionals.
.
.
.
III Ill 11 11 I I I 11 l . HONDA 00X31 -WSP-8000 I I I I Recycled Paper I I I PRINTED IN U.S.A. I I I I I.
An important point after buying a device Honda Automobiles WSP50 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Honda Automobiles WSP50 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Honda Automobiles WSP50 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Honda Automobiles WSP50 you will learn all the available features of the product, as well as information on its operation. The information that you get Honda Automobiles WSP50 will certainly help you make a decision on the purchase.
If you already are a holder of Honda Automobiles WSP50, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Honda Automobiles WSP50.
However, one of the most important roles played by the user manual is to help in solving problems with Honda Automobiles WSP50. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Honda Automobiles WSP50 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center