Model 66902

Read this material before using this product.
Failure to do so can result in serious injury. Save this manual.
Copyright© 2009 by Harbor Freight Tools®. All rights reserved. No portion of this manual or any artwork contained herein may be reproduced in any shape or form without the express written consent of Harbor Freight Tools. Diagrams within this manual may not be drawn proportionally. Due to continuing improve ments, actual product may differ slightly from the product described herein. Tools required for assembly and service may not be included.
For technical questions or replacement parts, please call 1-800-444-3353.
Revised Manual 09l

Keep this manual for the safety warn ings and precautions, assembly, operat ing, inspection, maintenance and cleaning procedures. Write the product’s serial number in the back of the manual near the assembly diagram (or month and year of purchase if product has no number). Keep this manual and the receipt in a safe and dry place for future reference.
INSTRUCTIONS Instructions Pertaining
Words
to a Risk of Fire, Electric Shock, or
In this manual, on the labeling, and all other information provid ed with this product:
This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death.
To reduce the risks of electric a.
shock, fire, and injury to persons, read all the instructions before us ing the tool.
Keep the work area clean and well a.
lighted. Cluttered benches and dark areas increase the risks of electric shock, fire, and injury to persons.
Do not operate the tool in explo b.
sive atmospheres, such as in the presence of flammable liquids, gases, or dust. The tool is able to create sparks resulting in the ignition of the dust or fumes.
Keep bystanders, children, and c.
visitors away while operating the

tool. Distractions are able to result in the loss of control of the tool.
g. Always wear hearing protection when using the tool. Prolonged expo sure to high intensity noise is able to cause hearing loss.
Stay alert. Watch what you are do a.
ing and use common sense when operating the tool. Do not use the tool while tired or under the influ ence of drugs, alcohol, or medica tion. A moment of inattention while operating the tool increases the risk of injury to persons.
Do not attach the hose or tool to h.
your body. Attach the hose to the structure to reduce the risk of loss of balance if the hose shifts.
Always assume that the tool con i.
tains fasteners. Do not point the tool toward yourself or anyone whether it contains fasteners or not.
Dress properly. Do not wear loose b.
clothing or jewelry. Contain long hair. Keep hair, clothing, and gloves away from moving parts. Loose clothes, jewelry, or long hair increases the risk of injury to persons as a result of being caught in moving parts.
top of another fastener. This is able to cause the fastener to be deflected and hit someone, or cause the tool to react and result in a risk of injury to persons.
Avoid unintentional starting. Be c.
the Trigger when not driving fas teners. Never carry the tool with finger on trigger, the tool is able to fire a fastener.
sure the Trigger (42) is off before connecting to the air supply. Do not carry the tool with your finger on the trigger or connect the tool to the air supply with the trigger on.
Do not overreach. Keep proper d.
footing and balance at all times. Proper footing and balance enables better control of the tool in unexpect ed situations.
Use clamps or another practical a.
way to secure and support the workpiece to a stable platform. Holding the work by hand or against the body is unstable and is able to lead to loss of control.
e. Use safety equipment. A dust mask, non-skid safety shoes and a hard hat must be used for the applicable conditions. Wear heavy-duty work gloves during use.
Do not force the tool. b. Use the correct tool for the application. The correct tool will do the job better and safer at the rate for which the tool is designed.
f. Always wear eye protec tion. Wear ANSI-ap proved safety goggles.
Do not use the tool if the Trigger c.
does not turn the tool on or off. Any tool that cannot be controlled

with the trigger is dangerous and must be repaired.
Tool service must be performed a.
Disconnect the tool from the air d.
only by qualified repair personnel.
source before making adjust ments, doing tool maintenance, clearing jams, touching the safety, leaving work area, loading, or un loading the tool. Such precautionary measures reduce the risk of injury to persons.
When servicing a tool, use only b.
identical replacement parts. Use only authorized parts.
Use only the lubricants supplied c.
with the tool or specified by the manufacturer.
Store the tool when it is idle out of e.
reach of children and other un trained persons. A tool is dangerous in the hands of untrained users.
a. Never connect to an air source that is capable of exceeding 90 PSI. Over pressurizing the tool may cause bursting, abnormal operation, breakage of the tool or serious injury to persons. Use only clean, dry, regulated compressed air at the rated pressure or within the rated pressure range as marked on the tool. Always verify prior to using the tool that the air source has been adjusted to the rated air pressure or within the rated air-pressure range.
Maintain the tool with care. f. A prop erly maintained tool is more efficient and reduces the risk of binding and is easier to control.
Check for misalignment or bind g.
ing of moving parts, breakage of parts, and any other condition that affects the tool’s operation. If dam aged, have the tool serviced before using. Many accidents are caused by poorly maintained tools. There is a risk of bursting if the tool is damaged.
Never use oxygen, carbon dioxide, b.
Use only accessories that are h.
combustible gases or any bottled gas as an air source for the tool. Such gases are capable of explosion and serious injury to persons.
identified by the manufacturer for the specific tool model. Use of an accessory not intended for use with the specific tool model, increases the risk of injury to persons.
Use only those fasteners listed i.
in the Accessories section of this manual. Fasteners not identified for use with this tool by the tool manu facturer are able to result in a risk of injury to persons or tool damage when used in this tool.

Keep fingers away from Trigger 2. when not driving fasteners to avoid accidental firing.
Always assume the tool contains 3. fasteners.
Do not point the tool toward yourself 4. or anyone whether it contains fasten ers or not.
Do not actuate the tool unless the 5. tool is placed firmly against the work piece.
Respect tool as a working implement. 6.
No horseplay. This tool is not a toy 7. and can be deadly if misused.
Do not load the tool with fasteners 8. when any one of the operating con trols is activated.
Do not remove, tamper with, or other 9. wise cause the tool operating controls to become inoperable.
Do not operate the tool if any portion 10. of the tool operating controls is inop erable, disconnected, altered, or not working properly.
Disconnect the tool from the power 11. source when:
Unattended. a.
Performing any maintenance or b.
repair.
Clearing a jam. c.
Moving the tool to a new location. d.
Operators and others in work area 1. MUST wear ANSI-approved safety goggles with side shields during use. The employer is responsible to enforce use of eye protection by the operator and others in the work area.
The written approval of the tool man 12. ufacturer must be obtained prior to making any modifications to the tool.
Refer to the tool maintenance instruc 13. tions for detailed information on the proper maintenance of the tool.

Fire fasteners into an appropriate 14. work surface only. Do not attempt to fire fasteners into surfaces too hard to penetrate. Do not drive fasteners on top of other fasteners, or at too steep of an angle. Fasteners can ricochet causing personal injury.
Do not fire fasteners too close to the 15. edge of a workpiece. They may split the workpiece and fly free, causing personal injury.
Transport Tool safely. Always dis 16. connect air supply when moving the tool. Carry the tool by the handle and avoid contact with the trigger.
Hold tool away from head and body. 17. During operation the Tool may kick back causing injury.
Do not fire fasteners into a workpiece 18. that has people, utility lines, or other objects behind or inside it.
Keep balance while using this tool. 19. Keep area below clear if working in a high location, and secure air hose to prevent falls from bystanders acci dentally pulling on it.
The warnings and precautions dis 25. cussed in this manual cannot cover all possible conditions and situations that may occur. It must be under stood by the operator that common sense and caution are factors which cannot be built into this product, but must be supplied by the operator.
Obey the manual for the air compres 20. sor used to power this tool.
Install in-line shutoff valve to allow im 21. mediate control over air supply in an emergency, even if hose is ruptured.
This tool vibrates during use. Re peated or long-term exposure to vibra tion may cause temporary or permanent physical injury, particularly to the hands, arms and shoulders. To reduce the risk of vibration-related injury:
Do not engrave or stamp anything 22. into the housing to prevent weaken ing of the housing.
Anyone using vibrating tools regu 1. larly or for an extended period should
Vibration Precautions

first be examined by a doctor and then have regular medical check- ups to ensure medical problems are not being caused or worsened from use. Pregnant women or people who have impaired blood circulation to the hand, past hand injuries, ner vous system disorders, diabetes, or Raynaud’s Disease should not use this tool. If you feel any symptoms related to vibration (such as tingling, numbness, and white or blue fingers), seek medical advice as soon as pos sible.
Do not smoke during use. Nico 2. tine reduces the blood supply to the hands and fingers, increasing the risk of vibration-related injury.
Safety - Also called the workpiece contact, the safety helps prevent the tool from firing unless it is pressed against an object.

Wear suitable gloves to reduce the 3. vibration effects on the user.
Use tools with the lowest vibration 4. when there is a choice between dif ferent processes.
Include vibration-free periods each 5. day of work.
Grip tool as lightly as possible (while 6. still keeping safe control of it). Let the tool do the work.
To reduce vibration, maintain tool as 7. explained in this manual. If abnormal vibration occurs, stop immediately.
Assembly
Read the entire Important
Safety Information section at the beginning of this manual including all text under subheadings therein before set up or use of this product.

the diagram above. An in-line shut off valve is an important safety device because it controls the air supply even if the air hose is rup tured.
the parts listed in the following pages, refer to the Assembly Diagram near the end of this manual.
used, add a few drops of Pneumatic Tool Oil to the airline connection be fore operation. Add a few more drops after each hour of continual use.
When unpacking, make sure item is intact and undamaged. If any parts are missing or broken, call Harbor Freight Tools at 1-800-444-3353.
This air tool may be shipped with a • protective plug covering the air inlet. Remove this plug before set up.
Attach an air hose to the compres 2. sor’s air outlet. Connect the air hose to the air inlet of the tool. Other components, such as a connector, air hose and quick coupler, will make operation more efficient, but are not required.
To prevent explosion: Use only clean, dry, regulated, compressed air to power tool. Do not use oxygen, carbon dioxide, combustible gases, or any other bottled gas as a power source for this tool.
injury from accidental operation: Do not install a female quick coupler on the tool. Such a coupler contains an air valve that will allow the air tool to retain pressure and operate accidentally after the air supply is disconnected.
mance, can be hindered by under sized air supply components.
The air hose must be long enough 3. to reach the work area with enough extra length to allow free movement while working.
Release the tool’s trigger. 4.
Close the in-line safety valve be 5. tween the compressor and the tool.
Turn on the air compressor according 6. to the manufacturer’s directions and allow it to build up pressure until it cycles off.

Adjust the air compressor’s output 7. regulator so that the air output is enough to properly power the tool, but the output will not exceed the tool’s maximum air pressure at any time. Adjust the pressure gradually, while checking the air output gauge to set the right pressure range.
are found, do not use tool until repaired.
Designate a work area that is clean 1. and well-lit. The work area must not allow access by children or pets to prevent injury and distraction.
The air pressure setting must not ex 8. ceed job site regulations/restrictions. The air pressure setting must not exceed 90 PSI when being used with work pieces that have a thickness of less than 1-3/4”.
Route the air hose along a safe route 2. to reach the work area without creat ing a tripping hazard or exposing the air hose to possible damage. The air hose must be long enough to reach the work area with enough extra length to allow free movement while working.
Inspect the air connections for leaks. 9. Repair any leaks found.
If the tool will not be used at this 10. time, turn off and detach the air sup ply, safely discharge any residual air pressure, and release the trigger to prevent accidental operation.
Secure loose workpieces using 3. clamps (not included) to prevent movement while working.
There must not be hazardous ob 4. jects (such as utility lines or foreign objects) nearby that will present a hazard while working.
present after the tool is disconnected from the air supply. However, it is a good safety measure to attempt to discharge the tool in a safe fashion after disconnecting to ensure that the tool is disconnected and unpowered.
Mechanism Definition
This tool has a full sequential safety trip mechanism, which is designed to prevent inadvertent firing. The tool should only fire if the Safety Nosepiece is pressed against the workpiece prior to pulling the Trigger. It should only fire again if both Trigger and Safety Nosepiece are re leased first. The Tool should not fire if the Safety Nosepiece is not pressed against the workpiece.
Read the entire Important
Safety Information section at the beginning of this manual including all text under subheadings therein before set up or use of this product.
Inspect tool before use, looking for damaged, loose, and missing parts. If any problems
Rev 09d

held, carefully lift the tool and press it against the workpiece again. The tool must not cycle (fire). If it fails to perform in the manner explained in bold, have it repaired by a qualified service technician.
To prevent serious injury from accidental operation: Empty the tool before this procedure. Point the tool at a piece of scrap wood when testing.
Disconnect 1. the tool from the air sup ply.
Empty the Magazine of fasteners. 2.
Check that the Trigger and the Safety 3. Nosepiece move freely, without stick ing.
Connect the air supply to the tool and 4. set within the Operating Air Pressure indicated on the Specification chart.
Test the tool by pressing the Safety 5. Nosepiece against the workpiece without pulling the Trigger. The Tool must not cycle (fire). If it cycles (fires), stop immediately and have it repaired by a qualified service techni cian.
To prevent serious injury from accidental operation: Release the trigger, detach the air supply, and safely discharge any residual air pressure in the tool before loading. Keep the Tool pointed away from yourself and others at all times. Do not load fasteners with the Trigger or Safety depressed.
Hold the tool away or off of the work 6. piece. The Safety Nosepiece should return to its original position. Squeeze the Trigger. The tool must not cycle (fire). If the tool fires, stop immedi ately and have it repaired by a quali fied service technician.
Press the Safety Nosepiece against 7. the workpiece and squeeze the Trigger. The tool must cycle (fire) only once. Release the Trigger and squeeze it again. The tool must not cycle (fire). With the Trigger
Depress the Click Lever (74) to 1. release the spring-loaded Magazine (67) from the Magazine Cover (61).
Slide the Magazine out. 2. Rev 09d

Insert the required size Fasteners 3. (3/4” - 2” L 16-gauge Brad Nails or 1/2” - 1-1/2” L18-gauge Crown Nar row Staples) into the Magazine.
use the supplied Plastic Cap (86) on the Safety.
If the tool requires more force to 8. accomplish the task, verify that the tool receives sufficient, unobstructed airflow (CFM) and increase the pressure (PSI) output of the regulator up to the maximum air pressure rating of this tool. CAUTION! To prevent tool and accessory failure, resulting in injury: Do not exceed the tool’s maximum air pressure rating. If the tool still does not have sufficient force at maximum pressure and sufficient airflow, then a larger tool may be required.
Slide the Magazine back into place 4. until it clicks.
Before each use, test the Tool, as 1. directed in the prior section.
If an automatic oiler is not used, 2. add a few drops of Pneumatic Tool Oil to the airline connection before use. Add a few drops more after each hour of continual use.
Grip the Body (24) of the Nailer with 3. both hands and press the nose piece against the surface you wish to fas ten. Be sure to keep hands, fingers and other body parts away from Nozzle.
To prevent accidents, turn off the 9. tool, detach the air supply, safely discharge any residual air pressure in the tool, and release the trigger after use. Clean external surfaces of the tool with clean, dry cloth, and apply a thin coat of tool oil. Then store the tool indoors out of children’s reach.
Push the nose piece on a scrap 4. material, preferably the same thick ness and type of material as the workpiece. Press the Trigger (42) to activate the Nailer. Performing this test-firing will help you to set the cor rect air pressure (not exceeding 90 PSI) to properly drive the fastener.
Grip the Body (24) of the Nailer with 5. both hands and press the Nozzle against the surface you wish to fas ten. Be sure to keep hands, fingers and other body parts away from the Nozzle.
explained in this manual must be performed only by a qualified technician.
To prevent serious injury from accidental operation, BEFORE ANY MAINTENANCE OR REPAIRS ARE DONE (including clearing jams):
Press the Trigger (42) to activate the 6. Nailer.
To avoid indenting or marring when 7. working on the face of fine surfaces,
Procedures not specifically · Rev 09d, 09l

explained as part of the regular op eration of the air-operated tool.
Daily - Air Supply Maintenance: 1. Every day, perform maintenance on the air supply according to the com ponent manufacturers’ instructions. The lubricator’s oil level needs to be maintained and the moisture filter must be regularly drained. Perform ing routine maintenance on the air supply will allow the tool to operate more safely and will also reduce wear on the tool.
To prevent serious injury from tool failure: Do not use damaged equipment. If abnormal noise, vibration, or leaking air occurs, have the problem corrected before further use.
To prevent explosion: Lubricate only with specified lubricants. Lubricate the air inlet using only pneumatic tool oil. Lubricate the internal mechanism using only white lithium grease. Other lubricants may damage the mechanism and may be highly flammable, causing an explosion.
Lubrication
If a fastener is jammed in the dis 1. charge area, remove it with pliers.
the regular checks and maintenance
If a fastener is jammed in the maga 2. zine, pull the Pusher all the way

back to the engaged position. Use a screwdriver to release the jammed fastener by probing the openings in the magazine.
remaining fastener strip; it may be bent or damaged in some other way.
If unable to clear jam using the meth 4. od prescribed above, the tool should be repaired by a qualified service technician.
Pull out the jammed fastener and the 3. remainder of the fastener strip that is still in the magazine. Dispose of the
Problem Possible Causes Likely Solutions
Insufficient fastener depth.
Incorrect tool depth setting. 1. Not enough air pressure. 2.
Adjust depth setting, if available. 1. Check for loose connections and make 2. sure that air supply is providing enough air pressure (PSI) to the tool’s air inlet. Do not exceed maximum air pressure. Lubricate using air tool oil and grease 3. according to directions. Clean air inlet screen of buildup. 4.
Incorrect lubrication or not 3. enough lubrication. Blocked air inlet screen (if 4. equipped). Mechanism contaminated. 5.
Have qualified technician clean and lubricate 5. mechanism. Install in-line filter in air supply as stated in Initial Set Up: Air Supply.
Fasteners drive too deeply.
Incorrect tool depth setting. 1. Too much air pressure. 2. Adjust depth setting, if available. 1. Reduce air supply pressure (PSI). 2.
Tool cycles without firing fastener.
Tool empty. 1. Incorrect fastener used. 2. Magazine dirty or not 3. lubricated properly. Insufficient air flow. 4.
Fill with correct fastener. 1. Empty, then fill with correct fastener. 2. Clean and lubricate magazine and pusher. 3.
Check for loose connections and make 4. sure that air supply is providing enough air flow (CFM) and pressure (PSI) to the tool’s air inlet. Do not exceed maximum air pressure.
Frequent jamming.
Incorrect fastener type. Confirm fastener diameter, type, length, angle, and collation type. Correct as needed.
Severe air leakage. (Slight air leakage is normal, especially on older tools.)
Cross-threaded housing 1. components.
Check for incorrect alignment and uneven 1. gaps. If cross-threaded, disassemble and replace damaged parts before use. Tighten housing assembly. If housing cannot 2. tighten properly, internal parts may be misaligned. Replace damaged components. 3. Clean or replace valve assembly. 4.
Loose housing. 2.
Damaged valve or housing. 3. Dirty, worn or damaged valve. 4.
Follow all safety precautions whenever diagnosing or servicing the tool. Disconnect air supply before service.

Part Description Q’ty 1 Shoulder Screw 1 2 Exhaust Deflector 1 3 O-Ring 1 4 Spring Washer 4 5 Hex Bolt 4 6 Head Cap 1 7 O-Ring 1 8 Gasket 1 10 Seal 1 11 Spring 1 12 Head Valve Piston 1 13 O-Ring 1 14 O-Ring 1 15 O-Ring 1 16 Collar 1 17 O-Ring 1 18 O-Ring 1 19 Driver Unit 1 20 O-Ring 1 21 Cylinder 1 22 O-Ring 1 23 Bumper 1 24 Body 1 25 Nozzle 1 26 Seal 1 27 Upper Trigger Valve 1 28 O-Ring 1 29 O-Ring 1 30 Trigger Valve Piston 1 31 O-Ring 1 32 O-Ring 1 33 Spring 1 34 Trigger Plunger 1 35 O-Ring 2 36 O-Ring 1 37 Lower Trigger Valve 1 38 Pin 1 39 Spring 1 40 Trigger Plate 1 41 O-Ring 1 42 Trigger 1 43 Retainer Pin 1 44 Safety Guide 1 45 Pin 1
Part Description Q’ty 46 Spring Washer 2 47 Head Screw 2 48 Head Cover 1 49 Hex Bolt 3 50 Safety 1 51 Depth Adjusting Knob 1 52 Adjusting Guide 1 53 E-Ring 1 54 Spring 1 55 Spacer A 1 56 Hex Bolt 2 57 Driver Guide Cover 1 58 Driver Guide 1 59 Hex Bolt 1 60 Spacer B 1 61 Magazine Cover 1 62 Steel Bar 1 63 Pusher Unit 1 64 Spring Holder 2 65 O-Ring 1 66 Spring 2 67 Magazine 1 68 Hex Bolt 2 69 Nail Positioner 1 70 Tail Hanger 1 71 Nut 1 72 Hex Bolt 1 73 Retainer Pin 1 74 Click Lever 1 75 Spring 1 76 O-Ring 1 77 Hex Bolt 1 78 Cylinder Pin 1 79 Tail Cover 1 80 Nut 2 81 Rubber Grip 1 82 Packing 1 83 End Cap 1 84 Hex Bolt 3 85 Air Plug 1 86 Plastic Cap 1 87 Nut 1 88 Hex Bolt 1
Record Product’s Serial Number Here:
able individually as replacement parts.


The manufacturer and/or distributor has provided the parts list and assembly diagram in this manual as a reference tool only. Neither the manufacturer or distributor makes any representation or warranty of any kind to the buyer that he or she is qualified to make any repairs to the product, or that he or she is qualified to replace any parts of the product. In fact, the manufacturer and/ or distributor expressly states that all repairs and parts replacements should be undertaken by certified and licensed technicians, and not by the buyer. The buyer assumes all risk and liability arising out of his or her repairs to the original product or replacement parts thereto, or arising out of his or her installation of replacement parts thereto.

Harbor Freight Tools Co. makes every effort to assure that its products meet high quality and durability standards, and warrants to the original purchaser that this product is free from defects in materials and workmanship for the period of one year from the date of purchase (90 days if used by a professional contractor or if used as rental equip ment). This warranty does not apply to damage due directly or indirectly, to misuse, abuse, negligence or accidents, repairs or alterations outside our facilities, normal wear and tear, or to lack of maintenance. We shall in no event be liable for death, injuries to persons or property, or for incidental, contingent, special or consequential damages arising from the use of our product. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation of exclusion may not ap ply to you. This warranty is expressly in lieu of all other warranties, express or implied, including the warranties of merchantability and fitness.
To take advantage of this warranty, the product or part must be returned to us with transportation charges prepaid. Proof of purchase date and an explanation of the com plaint must accompany the merchandise. If our inspection verifies the defect, we will ei ther repair or replace the product at our election or we may elect to refund the purchase price if we cannot readily and quickly provide you with a replacement. We will return re paired products at our expense, but if we determine there is no defect, or that the defect resulted from causes not within the scope of our warranty, then you must bear the cost of returning the product.
This warranty gives you specific legal rights and you may also have other rights which vary from state to state.
Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| Insufficient fastener depth. | 1. Incorrect tool depth setting. 2. Not enough air pressure. 3. Incorrect lubrication or not enough lubrication. 4. Blocked air inlet screen (if equipped). 5. Mechanism contaminated. | 1. Adjust depth setting, if available. 2. Check for loose connections and make sure that air supply is providing enough air pressure (PSI) to the tool’s air inlet. Do not exceed maximum air pressure. 3. Lubricate using air tool oil and grease according to directions. 4. Clean air inlet screen of buildup. 5. Have qualified technician clean and lubricate mechanism. Install in-line filter in air supply as stated in Initial Set Up: Air Supply. | p.13 |
| Fasteners drive too deeply. | 1. Incorrect tool depth setting. 2. Too much air pressure. | 1. Adjust depth setting, if available. 2. Reduce air supply pressure (PSI). | p.13 |
| Tool cycles without firing fastener. | 1. Tool empty. 2. Incorrect fastener used. 3. Magazine dirty or not lubricated properly. 4. Insufficient air flow. | 1. Fill with correct fastener. 2. Empty, then fill with correct fastener. 3. Clean and lubricate magazine and pusher. 4. Check for loose connections and make sure that air supply is providing enough air flow (CFM) and pressure (PSI) to the tool’s air inlet. Do not exceed maximum air pressure. | p.13 |
| Frequent jamming. | Incorrect fastener type. | Confirm fastener diameter, type, length, angle, and collation type. Correct as needed. | p.13 |
| Severe air leakage. (Slight air leakage is normal, especially on older tools.) | 1. Cross-threaded housing components. 2. Loose housing. 3. Damaged valve or housing. 4. Dirty, worn or damaged valve. | 1. Check for incorrect alignment and uneven gaps. If cross-threaded, disassemble and replace damaged parts before use. 2. Tighten housing assembly. If housing cannot tighten properly, internal parts may be misaligned. 3. Replace damaged components. 4. Clean or replace valve assembly. | p.13 |
| Follow all safety precautions whenever diagnosing or servicing the tool. Disconnect air supply before service. | p.13 |
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.