Model 04041

3491 Mission Oaks Blvd., Camarillo, CA 93011 Visit our Web site at http://www.harborfreight.com
AND INSTRUCTIONS BEFORE USE.
Copyright© 2004 by Harbor Freight Tools®. All rights reserved. No portion of this manual or any artwork contained herein may be reproduced in any shape or form
without the express written consent of Harbor Freight Tools.
For technical questions, please call 1-800-444-3353.
Revised Manual 01/04, 05/04, 09/04
®

Nail Size (.113” to .131” Thick), 10 Gauge (Round Head), 2-3/16” to 3-1/2” Long; 21o Full Head Nails Magazine Capacity 60 Nails Operating PSI 70 to 125 PSI* Required Air CFM Intake 3 - 3.5 CFM at 90 PSI Accessories Carrying Case, Safety Goggles, Machine Oil, 180 Nails Features Single Sequential Safety Trip Mechanism, 360o Exhaust Flow Adjustment, Soft Rubber Grip, 1/4” NPT (18 TPI) Air Inlet with Screen, Adjustable Depth Drive Weight 9.9 Lbs.
* The air pressure setting must not exceed job site regulations/restrictions. The air pressure setting must not exceed 90 PSI when being used with work pieces that have a thickness of less than 1-3/4”.
You will need the manual for the safety warnings and precautions, assembly instructions, operating and maintenance procedures, parts list and diagram. Keep your invoice with this manual. Write the invoice number on the inside of the front cover. Keep the manual and invoice in a safe and dry place for future reference.
Read all instructions before using this tool!

Use eye and ear protection. Always wear ANSI approved impact safety goggles and appropriate hearing protection. Wear a full face shield if you are producing metal filings or wood chips. Wear an ANSI approved dust mask or respirator when working around metal, wood, and chemical dusts and mists. Other people in the work area must also wear ANSI approved impact safety goggles.
14. Check for damaged parts. Before using any tool, any part that appears damaged should be carefully checked to determine that it will operate properly and perform its intended function. Check for alignment and binding of moving parts; any broken parts or mounting fixtures; and any other condition that may affect proper operation. Any part that is damaged should be properly repaired or replaced by a qualified technician. Do not use the tool if the trigger does not operate properly.

18. Use proper size and type extension cord. If an extension cord is required, it must be of the proper size and type to supply the correct current to the compressor without heating up. Otherwise, the extension cord could melt and catch fire, or cause electri- cal damage to the tool. Check your air compressor’s manual for the appropriate size cord. It is also possible that the use of an extension cord may cause your circuit breaker to trip or your panel fuse to break. If this happens, either use the compres-
sor without an extension cord or find a larger amperage circuit to use.
Do not load nails with the trigger or safety depressed. Unintentional firing may occur. Do not load nails when the air hose is connected to the tool. Always assume that the tool contains fasteners.
construction activities, contain chemicals known [to the State of California] to cause cancer, birth defects or other reproductive harm. Some examples of these chemicals are:

variations in local line voltage. Extension cord usage may also affect tool performance.
When unpacking, check to make sure all the parts shown on the Parts List on page 11 are included. If any parts are missing or broken, please call Harbor Freight Tools at the number shown on the cover of this manual as soon as possible.

FIGURE A
For best service you should incorporate an oiler, regulator, and inline filter, as shown in the Figure A above. Hoses, couplers, oilers, regulators, and filters are all available at Harbor Freight Tools. 1. You will need to prepare a 1/4” air connector (sold separately) to connect to the air inlet on the Nailer. First, wrap the 1/4” air connector (not included) with pipe thread seal tape before connecting to a 3/8” ID Air Source Hose (not included). Connect the Air Source Hose to the Air Plug (79).
Pneumatic Tool Oil to the airline connection. Add a few drops more after each hour of continual use.
suggested that you experiment on scrap material.
Nailer/

point the Nailer at a piece of scrap wood when testing.
ALWAYS WEAR ANSI APPROVED IMPACT SAFETY GOGGLES WHEN RELOADING OR DOING ANY OTHER MAINTENANCE ON THIS TOOL. Other people in the work area must also wear ANSI approved impact safety goggles.
Warning! Make sure the Nailer is not attached to the air hose whenever loading the tool. 1. CAUTION: Make sure to keep the Framing Nailer pointed away from you and others at all times. Always disconnect the Framing Nailer from its air supply before loading nails. Do not load nails with the Trigger (part #44), or Bracket B (part #35), or Safety (part #38) depressed. (See Figure B)



NAILS (10 GAUGE) (2-3/16” TO 3-1/2” LONG)
(#52) NOSE (#29)
FEEDER SHOE

AIR SUPPLY HOSE
TRIGGER
(NOT INCLUDED)
BRACKET A
NOSE (#29)
SAFETY (38)
FIGURE B
To Adjust The Depth To Which A Nail Is Driven
(#44) · (#35)


SAFETY
RUBBER COVER (39)
FIGURE C
Anytime any maintenance or repairs are done (including clearing jams), FIRST:
Clearing Jams 1. Disconnect tool from air hose. Always fire the trigger repeatedly to make sure all of the air is expended from the Nailer.
3. If a nail is jammed in the magazine, pull the Feeder Shoe (#52) all the way back to the engaged position. Using a screwdriver, attempt to release the jammed nail by probing either or all of the openings in the magazine (see Figure D ) to release the nail. Pull out the jammed nail and the remainder of the nail strip that is still in the magazine. Dispose of the remaining nail strip; it may be bent or damaged in some other way. Reload the magazine with a new nail strip. Pull back on the Feeder Shoe (#52) and with your other hand, pull the tab down on the Lock (#67), and guide the Feeder Shoe (#52) back into position. If you are unable to clear the nail jam using the method prescribed above, the tool should be taken to a qualified service technician for proper servicing.
(#38)

Probe in these areas with a screwdriver to release jammed nails.



THE MANUFACTURER AND/OR DISTRIBUTOR HAS PROVIDED THE PARTS LIST AND ASSEMBLY DIAGRAM IN THIS MANUAL AS A REFERENCE TOOL ONLY. NEITHER THE MANUFACTURER OR DISTRIBUTOR MAKES ANY REPRESENTATION OR WARRANTY OF ANY KIND TO THE BUYER THAT HE OR SHE IS QUALIFIED TO MAKE ANY REPAIRS TO THE PRODUCT, OR THAT HE OR SHE IS QUALIFIED TO REPLACE ANY PARTS OF THE PRODUCT. IN FACT, THE MANUFACTUER AND/ OR DISTRIBUTOR EXPRESSLY STATES THAT ALL REPAIRS AND PARTS REPLACEMENTS SHOULD BE UNDERTAKEN BY CERTIFIED AND LICENSED TECHNICIANS, AND NOT BY THE BUYER. THE BUYER ASSUMES ALL RISK AND LIABILITY ARISING OUT OF HIS OR HER REPAIRS TO THE ORIGINAL PRODUCT OR REPLACEMENT PARTS THERETO, OR ARISING OUT OF HIS OR HER INSTALLATION OF REPLACEMENT PARTS THERETO.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.