Page 1 of the Harbor Freight Tools 04041 user manual — TO PREVENT SERIOUS INJURY, READ AND UNDERSTAND ALL WARNINGS
Page 1 · click to enlarge
Page 1

FRAMING NAILER 21 DEGREE ANGLED / 10 GAUGE

Model 04041

ASSEMBLY AND OPERATING INSTRUCTIONS

Harbor Freight Tools 04041 — ASSEMBLY AND OPERATING INSTRUCTIONS diagram (page 1)
Fig. 1

3491 Mission Oaks Blvd., Camarillo, CA 93011 Visit our Web site at http://www.harborfreight.com

TO PREVENT SERIOUS INJURY, READ AND UNDERSTAND ALL WARNINGS

AND INSTRUCTIONS BEFORE USE.

Copyright© 2004 by Harbor Freight Tools®. All rights reserved. No portion of this manual or any artwork contained herein may be reproduced in any shape or form

without the express written consent of Harbor Freight Tools.

For technical questions, please call 1-800-444-3353.

Revised Manual 01/04, 05/04, 09/04

®

Page 2 of the Harbor Freight Tools 04041 user manual — REV 01/04 REV 08/05 REV 01/06 REV 11/06
Page 2 · click to enlarge
Page 2

PRODUCT SPECIFICATIONS

Nail Size (.113” to .131” Thick), 10 Gauge (Round Head), 2-3/16” to 3-1/2” Long; 21o Full Head Nails Magazine Capacity 60 Nails Operating PSI 70 to 125 PSI* Required Air CFM Intake 3 - 3.5 CFM at 90 PSI Accessories Carrying Case, Safety Goggles, Machine Oil, 180 Nails Features Single Sequential Safety Trip Mechanism, 360o Exhaust Flow Adjustment, Soft Rubber Grip, 1/4” NPT (18 TPI) Air Inlet with Screen, Adjustable Depth Drive Weight 9.9 Lbs.

* The air pressure setting must not exceed job site regulations/restrictions. The air pressure setting must not exceed 90 PSI when being used with work pieces that have a thickness of less than 1-3/4”.

Save This Manual

You will need the manual for the safety warnings and precautions, assembly instructions, operating and maintenance procedures, parts list and diagram. Keep your invoice with this manual. Write the invoice number on the inside of the front cover. Keep the manual and invoice in a safe and dry place for future reference.

Safety Warnings and Precautions

Read all instructions before using this tool!

1. Keep work area clean . Cluttered areas invite injuries.
2. Observe work area conditions . Do not use machines or power tools in damp or wet locations. Do not expose to rain. Keep work area well lit. Do not use electrically powered tools in the presence of flammable gases or liquids.
3. Keep children away . Children must never be allowed in the work area. Do not let them handle machines, tools, extension cords, or air hoses.
4. Store idle equipment . When not in use, tools must be stored in a dry location to inhibit rust. Always lock up tools and keep out of reach of children.
5. Use the right tool for the job . Do not attempt to force a small tool or attachment to do the work of a larger industrial tool. There are certain applications for which this tool was designed. It will do the job better and more safely at the rate for which it was intended. Do not modify this tool and do not use this tool for a purpose for which it was not intended.
6. Dress properly . Do not wear loose clothing or jewelry as they can be caught in moving parts. Protective, electrically non-conductive clothes and non-skid footwear are recommended when working. Wear restrictive hair covering to contain long hair.
7. Do not overreach . Keep proper footing and balance at all times. Do not reach over or across running machines or air hoses.

REV 01/04 REV 08/05 REV 01/06 REV 11/06

Page 3 of the Harbor Freight Tools 04041 user manual — PRODUCT SPECIFICATIONS
Page 3 · click to enlarge
Page 3

Use eye and ear protection. Always wear ANSI approved impact safety goggles and appropriate hearing protection. Wear a full face shield if you are producing metal filings or wood chips. Wear an ANSI approved dust mask or respirator when working around metal, wood, and chemical dusts and mists. Other people in the work area must also wear ANSI approved impact safety goggles.

9. Maintain tools with care . Keep tools clean for better and safer performance. Follow instructions for lubricating and changing accessories. Inspect tool cords and air hoses periodically and, if damaged, have them repaired by an authorized technician. The handle must be kept clean, dry, and free from oil and grease at all times. Do not operate a tool if any portion of the tool’s operating controls are inoperable, disconnected, altered or not working properly.
10. Disconnect Air Hose and release any built-up air pressure . Never service the Nailer, clear jams, or disassemble with the air hose attached. Always release any built-up air even after disconnecting hose. Disconnect the Nailer when not in use.
11. Remove adjusting keys and wrenches . Check that keys and adjusting wrenches are removed from the tool or machine work surface before attaching to an air source.
12. Avoid unintentional starting . Be sure the trigger is in the Off position when not in use and before plugging in. Do not carry any tool with your finger on the trigger, whether it is attached to an air source or not. Do not point the tool towards yourself or anyone whether it contains fasteners or not.
13. Stay alert . Watch what you are doing, use common sense. Do not operate any tool when you are tired.

14. Check for damaged parts. Before using any tool, any part that appears damaged should be carefully checked to determine that it will operate properly and perform its intended function. Check for alignment and binding of moving parts; any broken parts or mounting fixtures; and any other condition that may affect proper operation. Any part that is damaged should be properly repaired or replaced by a qualified technician. Do not use the tool if the trigger does not operate properly.

15. Guard against electric shock . Prevent body contact with grounded surfaces such as pipes, radiators, ranges, and refrigerator enclosures.
16. Replacement parts and accessories . This product is to be repaired and serviced only by a qualified technician. When this product is serviced, only identical replacement parts should be used. Use of any other parts will void the warranty. Only use accessories intended for use with this tool. Approved accessories are available from Harbor Freight Tools.
17. Do not operate tool if under the influence of alcohol or drugs . Read warning labels if taking prescription medicine to determine if your judgement or reflexes are impaired while taking drugs. If there is any doubt, do not operate the tool.
Page 4 of the Harbor Freight Tools 04041 user manual — PRODUCT SPECIFICATIONS
Page 4 · click to enlarge
Page 4

18. Use proper size and type extension cord. If an extension cord is required, it must be of the proper size and type to supply the correct current to the compressor without heating up. Otherwise, the extension cord could melt and catch fire, or cause electri- cal damage to the tool. Check your air compressor’s manual for the appropriate size cord. It is also possible that the use of an extension cord may cause your circuit breaker to trip or your panel fuse to break. If this happens, either use the compres-

sor without an extension cord or find a larger amperage circuit to use.

19. Maintenance . The maintenance outlined in the maintenance section should be performed regularly. For your safety, this product should be serviced or repaired regularly only by a qualified technician.
20. Compressed air only . Never use combustible gas as a power source.

Do not load nails with the trigger or safety depressed. Unintentional firing may occur. Do not load nails when the air hose is connected to the tool. Always assume that the tool contains fasteners.

22. Disconnect air supply before loading Nailer . Before reloading (or making any adjustments to) the Nailer make sure that the compressed air is disconnected.
23. Fire nails into an appropriate work surface only . Do not attempt to fire nails into surfaces too hard to penetrate. Do not drive nails on top of other nails, or at too steep of an angle. Nails can ricochet causing personal injury. Never fire the Nailer into the air, or point it toward yourself or another person. Always wear ANSI approved safety goggles during use, maintenance, and reloading.
24. Do not fire nails too close to the edge of a workpiece . They may split the workpiece and fly free, causing personal injury.
25. Take caution as some woods contain preservatives such as copper chromium arsenate (CCA) which can be toxic . When or nailing these materials extra care should be taken to avoid inhalation and minimize skin contact.

construction activities, contain chemicals known [to the State of California] to cause cancer, birth defects or other reproductive harm. Some examples of these chemicals are:

  • Lead from lead-based paints
  • Crystalline silica from bricks and cement or other masonry products
  • Arsenic and chromium from chemically treated lumber (California Health & Safety Code 25249.5, et seq. )
26. Stay within air pressure capacity . Never operate the Nailer above 120 PSI.
27. Hold tool away from head and body . During operation the Nailer may kick back causing injury.
Page 5 of the Harbor Freight Tools 04041 user manual — 1/4”-18 NPT
Page 5 · click to enlarge
Page 5
28. Transport Nailer safely . Always disconnect air supply when moving the tool in the workplace. Carry the tool by the handle and avoid contact with the trigger.

variations in local line voltage. Extension cord usage may also affect tool performance.

UNPACKING

When unpacking, check to make sure all the parts shown on the Parts List on page 11 are included. If any parts are missing or broken, please call Harbor Freight Tools at the number shown on the cover of this manual as soon as possible.

OPERATION

Harbor Freight Tools 04041 — OPERATION diagram (page 5)
Fig. 2

1/4”-18 NPT

FIGURE A

For best service you should incorporate an oiler, regulator, and inline filter, as shown in the Figure A above. Hoses, couplers, oilers, regulators, and filters are all available at Harbor Freight Tools. 1. You will need to prepare a 1/4” air connector (sold separately) to connect to the air inlet on the Nailer. First, wrap the 1/4” air connector (not included) with pipe thread seal tape before connecting to a 3/8” ID Air Source Hose (not included). Connect the Air Source Hose to the Air Plug (79).

Pneumatic Tool Oil to the airline connection. Add a few drops more after each hour of continual use.

2. Set the air pressure on your compressor to 70 - 125 PSI. Do not exceed the maximum air pressure of 125 PSI.
3. Check the air connection for leaks.

suggested that you experiment on scrap material.

4. Check the air connection for leaks and disconnect the Nailer.

Nailer/

Page 6 of the Harbor Freight Tools 04041 user manual — Loading Nails
Page 6 · click to enlarge
Page 6

Testing The Single Sequential Safety Trip Mechanism

point the Nailer at a piece of scrap wood when testing.

1. The Nailer should not fire if the nose is not depressed against the workpiece. This tool has a single sequential safety trip mechanism, which is designed to prevent inadvertent firing. The tool will only fire if the Safety (38) is resting on the workpiece prior to pulling the Trigger (44).
2. Make sure the tool is disconnected from the air supply. 3. Empty the magazine of nails or staples.
4. Check that the Trigger (44) and the Safety (38) on the nose of the tool, move freely, without sticking.
5. Connect the air supply to the tool at the Air Plug (79) and set at the recommended 70125 PSI, and not over the maximum 125 PSI.
6. Test the tool by depressing the Safety (38) on the nose of the tool against the workpiece without pulling the Trigger (44). The tool must not cycle (fire) . If it cycles (fires), stop immediately and take the tool to a qualified service technician for repair.
7. Hold the tool away, or off of the workpiece. The Safety (38) or nose of the tool should return to its original position. Squeeze the Trigger (44). The tool should not cycle (fire). If it cycles (fires), stop immediately and take the tool to a qualified service technician.
8. Depress the Safety (38) against the workpiece and squeeze the Trigger (44). The tool must cycle (fire) once only . Release the trigger and squeeze it again. The tool must cycle (fire) again only once. With the Trigger held, carefully lift the nailer and press it against the workpiece again. The tool must not cycle (fire) . If it fails to act in the manner explained in bold, have it repaired by a qualified service technician.

Loading Nails

ALWAYS WEAR ANSI APPROVED IMPACT SAFETY GOGGLES WHEN RELOADING OR DOING ANY OTHER MAINTENANCE ON THIS TOOL. Other people in the work area must also wear ANSI approved impact safety goggles.

Warning! Make sure the Nailer is not attached to the air hose whenever loading the tool. 1. CAUTION: Make sure to keep the Framing Nailer pointed away from you and others at all times. Always disconnect the Framing Nailer from its air supply before loading nails. Do not load nails with the Trigger (part #44), or Bracket B (part #35), or Safety (part #38) depressed. (See Figure B)

2. Pull the Feeder Shoe (part #52) all the way to the rear, until it latches. (See Figure B.)
Page 7 of the Harbor Freight Tools 04041 user manual — OPERATION
Page 7 · click to enlarge
Page 7

Loading Nails (continued)

3. Orient a strip of nails with the points down, and drop the strip of nails into the Magazine (part #71). (See Figure C.)
4. Slide the strip of nails forward in the Magazine (part #71). NOTE: The Magazine will hold 60, 10 gauge nails. (See Figure C.)
5. Unlatch the Feeder Shoe (part #52), and allow the Feeder Shoe to slide forward against the strip of nails. (See Figure C.)

OPERATION

1. Adjust the Exhaust Cover (4) to direct exhaust as desired.
2. To fire a nail, place the nose of the Nailer on the workpiece. The Nailer should not fire if the Safety (38) is not depressed. Once the Safety is depressed, gently and briefly squeeze the Trigger once to fire one nail. Release the Trigger . Do not fire repeatedly; nails could bounce off on one another, damaging the workpeice or causing personal injury.
3. With the nose of the Nailer on the workpiece, squeeze the Trigger again to fire another nail. Continue firing nails as needed.
4. When the work is completed, disconnect the air supply and remove the nails from the nailer.
Page 8 of the Harbor Freight Tools 04041 user manual — QUICK COUPLER &
Page 8 · click to enlarge
Page 8
Harbor Freight Tools 04041 — EXHAUST COVER (#4) diagram (page 8)
Fig. 3

EXHAUST COVER (#4)

NAILS (10 GAUGE) (2-3/16” TO 3-1/2” LONG)

(#52) NOSE (#29)

FEEDER SHOE

Harbor Freight Tools 04041 — EXHAUST COVER (#4) diagram (page 8)
Fig. 4

QUICK COUPLER &

AIR SUPPLY HOSE

TRIGGER

(NOT INCLUDED)

BRACKET A

NOSE (#29)

SAFETY (38)

FIGURE B

To Adjust The Depth To Which A Nail Is Driven

1. The depth to which a nail is driven is controlled by the Safety (part #38). (See Figures B and C).
2. To adjust the depth of drive, loosen the Screw (part #37). Slide Safety (part #38) up or down to the desired position. Then, re-tighten the Screw. Note : Sliding Safety (38) upward increases the depth of drive. Sliding Safety downward decreases the depth of drive. (See Figure C) .
3. Test fire a nail, and check its depth of drive. Repeat Step #2 as necessary to achieve the desired depth of drive. (See Figure C) .

(#44) · (#35)

Page 9 of the Harbor Freight Tools 04041 user manual — SCREW (#37)
Page 9 · click to enlarge
Page 9
Harbor Freight Tools 04041 — SCREW (#37) diagram (page 9)
Fig. 5

SCREW (#37)

SAFETY

RUBBER COVER (39)

FIGURE C

Anytime any maintenance or repairs are done (including clearing jams), FIRST:

1. Disconnect the Nailer from the air hose. 2. Empty the Magazine (71) completely. 3. Attempt to fire the Nailer into a piece of scrap wood to ensure that it is disconnected and is incapable of firing any brads. 4. Always leave the Magazine (71) open during maintenance. The Magazine is springloaded and may cause parts or a nail to fly out of the Nailer.

Clearing Jams 1. Disconnect tool from air hose. Always fire the trigger repeatedly to make sure all of the air is expended from the Nailer.

2. If a nail is jammed in the discharge area, simply remove it with pliers.

3. If a nail is jammed in the magazine, pull the Feeder Shoe (#52) all the way back to the engaged position. Using a screwdriver, attempt to release the jammed nail by probing either or all of the openings in the magazine (see Figure D ) to release the nail. Pull out the jammed nail and the remainder of the nail strip that is still in the magazine. Dispose of the remaining nail strip; it may be bent or damaged in some other way. Reload the magazine with a new nail strip. Pull back on the Feeder Shoe (#52) and with your other hand, pull the tab down on the Lock (#67), and guide the Feeder Shoe (#52) back into position. If you are unable to clear the nail jam using the method prescribed above, the tool should be taken to a qualified service technician for proper servicing.

(#38)

Page 10 of the Harbor Freight Tools 04041 user manual — INSPECTION, MAINTENANCE, AND CLEANING
Page 10 · click to enlarge
Page 10

FIGURE D

Probe in these areas with a screwdriver to release jammed nails.

Anytime any maintenance or repairs are done (including clearing jams), FIRST:

1. Disconnect the Nailer from the air hose. 2. Empty the Magazine (71) completely. 3. Attempt to fire the Nailer into a piece of scrap wood to ensure that it is disconnected and is incapable of firing any brads. 4. Always leave the Magazine (71) open during maintenance. The Magazine is springloaded and may cause parts or a nail to fly out of the Nailer.

INSPECTION, MAINTENANCE, AND CLEANING

1. CAUTION: Always disconnect the Framing Nailer from its compressed air supply source before performing any inspection, maintenance, or cleaning.
2. BEFORE EACH USE, inspect the general condition of the Framing Nailer. Check for loose screws, misalignment or binding of moving parts, jammed nails, cracked or broken parts, damaged air supply hose, and any other condition that may affect the safe operation of this tool. If abnormal noise or vibration occurs, immediately disconnect the Framing Nailer from its compressed air supply source and have the problem corrected before further use. Do not use damaged equipment.
3. PERIODICALLY, use a premium quality, lightweight oil to lubricate all moving parts.
4. When necessary, wipe with a damp cloth, using a mild detergent or mild solvent.
5. When storing, keep the Framing Nailer in its Carrying Case (part #80) or covered with a clean cloth.
Page 11 of the Harbor Freight Tools 04041 user manual — FIGURE D
Page 11 · click to enlarge
Page 11
Harbor Freight Tools 04041 — FIGURE D diagram (page 11)
Fig. 6
Page 12 of the Harbor Freight Tools 04041 user manual — PLEASE READ THE FOLLOWING CAREFULLY
Page 12 · click to enlarge
Page 12

PLEASE READ THE FOLLOWING CAREFULLY

THE MANUFACTURER AND/OR DISTRIBUTOR HAS PROVIDED THE PARTS LIST AND ASSEMBLY DIAGRAM IN THIS MANUAL AS A REFERENCE TOOL ONLY. NEITHER THE MANUFACTURER OR DISTRIBUTOR MAKES ANY REPRESENTATION OR WARRANTY OF ANY KIND TO THE BUYER THAT HE OR SHE IS QUALIFIED TO MAKE ANY REPAIRS TO THE PRODUCT, OR THAT HE OR SHE IS QUALIFIED TO REPLACE ANY PARTS OF THE PRODUCT. IN FACT, THE MANUFACTUER AND/ OR DISTRIBUTOR EXPRESSLY STATES THAT ALL REPAIRS AND PARTS REPLACEMENTS SHOULD BE UNDERTAKEN BY CERTIFIED AND LICENSED TECHNICIANS, AND NOT BY THE BUYER. THE BUYER ASSUMES ALL RISK AND LIABILITY ARISING OUT OF HIS OR HER REPAIRS TO THE ORIGINAL PRODUCT OR REPLACEMENT PARTS THERETO, OR ARISING OUT OF HIS OR HER INSTALLATION OF REPLACEMENT PARTS THERETO.

Ask about the Harbor Freight Tools 04041

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Harbor Freight Tools 04041

Be the first to ask — other owners or our team will answer.

Original document

Harbor Freight Tools 04041 manual PDF

12 pages·193 KB·Nail Gun·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…