10:1 Fire–Ball 425 Pump
309407E

Low–pressure, medium volume pump used to transfer grease.
1800 psi (12.4 MPa, 124 bar) Maximum Working Pressure 180 psi (1.3 MPa, 13 bar) Maximum Air Inlet Pressure
Model No. 965129, Series B, 400 lb (180 Kg) drum length For Closed Drum Mounting
This pump is designed to be used only in pumping non-corrosive and non-abrasive lubricants. Any other use of the pump can cause unsafe operating conditions and component rupture, which can re- sult in fluid injection or other serious injury or fire or explosion.


Improper grounding, poor ventilation, open flames, or sparks can cause a hazardous condition and result in a fire or explosion and serious injury.
Ground the equipment and the object being dispensed to. Refer to Grounding on page 5.
If there is any static sparking or you feel an electric shock while using this equipment, stop dis- pensing immediately. Do not use the equipment until you identify and correct the problem.
Provide fresh air ventilation to avoid the buildup of flammable fumes from solvents or the fluid being dispensed.
Keep the dispensing area free of debris, including solvent, rags, and gasoline.
Do not smoke in the dispensing area.
Do not turn on or off any light switch in the area while dispensing if fumes are present.
Never use 1.1.1–trichloroethane, methylene chloride, other halogenated hydrocarbon solvents, or fluids containing such solvents in pressurized aluminum equipment. Such use could result in a chemical reaction, with the possibility of explosion.
Hazardous fluid or toxic fumes can cause serious injury or death if splashed in the eyes or on the skin, inhaled, or swallowed.
Know the specific hazards of the fluid you are using.
Store hazardous fluid in an approved container. Dispose of hazardous fluid according to all local, state, and national guidelines.
Always wear protective eyewear, gloves, clothing, and respirator as recommended by the fluid and solvent manufacturer.
The air motor exhausts any fluids added to the input air.
Graco does not manufacture or supply the reactive chemical components that may be used in this equipment and is not responsible for injury or property loss, damage, expense, or claims (direct or consequential) that arise from the use of such chemical components.
3 309407

Equipment misuse can cause the equipment to rupture or malfunction and result in serious injury.
This equipment is for professional use only.
Read all instruction manuals, tags, and labels before operating the equipment.
Use the equipment only for its intended purpose. If you are not sure, call your Graco distributor.
Do not alter or modify this equipment.
Check equipment daily. Repair or replace worn or damaged parts immediately.
Do not exceed the maximum working pressure stated on the equipment or in the Technical Data for your equipment. Do not exceed the maximum working pressure of the lowest rated component in your system.
Use fluids and solvents which are compatible with the equipment wetted parts. Refer to the Tech- nical Data section of all equipment manuals. Read the fluid and solvent manufacturer’s warnings.
Handle hoses carefully. Do not pull on hoses to move equipment.
Route hoses away from traffic areas, sharp edges, moving parts, and hot surfaces. Do not expose Graco hoses to temperatures above 66C (150F) or below –40C (–40F).
Wear hearing protection when operating this equipment.
Do not move or lift pressurized equipment.
Comply with all applicable local, state, and national fire, electrical, and safety regulations.
4 309407

Dispensing valve: Ground through connection to a properly grounded fluid hose and pump.
Object being dispensed to: Follow your local code.
Solvent pails used when flushing: Follow your local code. Use only metal pails, which are conductive, placed on a grounded surface. Do not place the pail on a nonconductive surface, such as paper or cardboard, which interrupts the grounding continuity.
FIRE AND EXPLOSION HAZARD Before operating the pump, ground the system as explained below. Also read the section FIRE OR EXPLOSION HAZ- ARD on page 3.
To maintain grounding continuity when flushing or relieving pressure, hold a metal part of the dispensing gun firmly to the side of a grounded metal pail, then trigger the gun to ground the pump.
To ground the pump, remove the ground screw (Z) and insert through the eye of the ring terminal at end of ground wire (Y). Fasten the ground screw back onto the pump and tighten securely. Connect the other end of the ground wire to a true earth ground. See Fig. 1. To order a ground wire and clamp, order Part No. 222011.
Pump: Use a ground wire and clamp as shown below.
Mounting the Pump
Mount the pump securely so that it cannot move around during operation. Failure to do so could result in personal injury or equipment damage.
Air and fluid hoses: Use only electrically conductive hoses.
Select a convenient location for the equipment to ensure easy operator access to the pump air controls, sufficient room to change supply containers, and a secure mounting platform.
Air compressor: Follow manufacturer’s recommendations.
If you are mounting the pump directly on the supply tank, position the pump so its intake valve is no more than 1 in. (25 mm) from the bottom of the container. Mount the pump to the cover or other suitable mounting device.
5 309407

Mount the pump to suit the type of installation planned. Very heavy lubricants may require an inductor plate. See page 16 for the mounting hole layout and dimensions
A bleed-type master air valve (B) is required to shut off and relieve air pressure that may be trapped in the air motor. Trapped air could cause the pump to cycle unexpectedly and cause serious bodily injury, including amputation.
Install the air line accessories in the approximate order shown in the Typical Installation. Install a bleed-type master air valve (B) within easy reach of the pump, upstream from the air regulator. Install an air filter (C) to remove harmful dirt and moisture from your compressed air supply. For automatic air motor lubrication, install an air line oiler (D) close to the pump air inlet. Install an air regulator (E) to control pump speed.
Be sure the air hose is properly sized to deliver an adequate supply of air to the motor. Refer to the Technical Data on page 17.
Connect a dispensing hose to the 3/4 npt(f) pump outlet. Install an appropriate gun or dispensing valve to the hose.
Ground the pump as explained on page 5.
A B C D E F H J K L
Grounded Air Line Bleed-type Master Air Valve Air Filter Air Line Oiler Air Regulator Grounded Dispensing Hose Elevator Assy. 241663 Ground Wire Follow Plate 223701 Drum Cover 200326
C D
J
E
B
F
K
H
TI2371A
Key · 6 309407

Open the bleed-type master air valve. Open the dispensing valve, and slowly open the air regulator until the pump is running smoothly. After all the air is purged, close the dispensing valve. The pump will start and stop as the valve is opened and closed.
This pump is designed to be used ONLY in pumping non-corrosive and non-abrasive lubri- cants and greases. Any other use of this pump can cause unsafe operating conditions and result in component rupture, fire, or explosion, which can can cause serious bodily injury, including injection.
Never allow the pump to run dry of the fluid being pumped. A dry pump quickly accelerates to a high speed and may damage itself. If your pump acceler- ates quickly or is running too fast, stop it immediately and check the fluid supply. If the supply container is empty and air has been pumped into the lines, prime the pump and lines with fluid, or flush the pump and leave it filled with a compatible solvent. Be sure to eliminate all air from the fluid system.
Moving parts can pinch or amputate your fin- gers or other body parts. When the pump is operating, the priming piston (located at the pump intake) and the air motor piston (located behind the air motor plates) move. NEVER Operate the pump with the air motor plates removed, and keep your fingers and hands away from the priming piston.
Use the air regulator (E) to control the pump speed and fluid pressure. See Fig. 2. Always use the lowest pressure necessary to obtain the desired results.
When you are finished using the pump for the day, always follow the Pressure Relief Procedure at left.
SKIN INJECTION HAZARD Fluid under high pressure can be in- jected through the skin and cause serious injury. To reduce the risk of an injury from injection, splashing fluid, or moving parts, follow the Pressure Relief Procedure whenever you
The Accessory air line oiler (D) provides automatic air motor lubrication. For daily manual lubrication, disconnect the air hose, place about 15 drops of light machine oil in the air inlet, reconnect the hose, and turn on the air supply to blow oil into the motor.
Are instructed to relieve the pressure Stop dispensing Check or service any of the system equipment Install or clean the dispensing nozzles
If you suspect that the dispensing valve, extension, or grease fitting coupler is clogged, or that pressure has not been fully relieved after following the steps above, VERY SLOWLY loosen the coupler or hose end coupling and relieve pressure gradually, then loosen completely, then clear the clog.
7 309407

Before servicing this equipment always make sure to Relieve the Pressure.
To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 7.
* Follow the Pressure Relief Procedure, and disconnect the fluid line. If the pump starts when the air is turned back on, the fluid line, hose, valve, etc. was clogged.
8 309407

9 309407


TI2148A Fig. 3
10 309407

To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 7.
Before you start:
1. Reassemble the piston, using all the new parts from the kit and any other new parts needed. Oil the leather cup packings (36*) first. Then assemble the parts on the piston housing (16) in this order: backup washer (35*), spreader (34*), leather packing (36*), cup spacer (20) with new o–ring (33*) installed in it, another leather packing (36*), spreader (34*), and backup washer (35*). NOTE: To replace the throat packings, follow the procedure given in your separate air motor manual (306982) before continuing with the procedure.
To reduce down time, be sure you have all necessary repair parts available.
Repair Kit 237498 is available. If you have a repair kit, use all the new parts for the best results. Parts included in the kit are marked with an asterisk (*).
When cleaning parts, use a compatible solvent. Inspect parts for wear or damage and replace as necessary. Scoring or irregular surfaces on the priming rod (8) or polished inner wall of the riser tube (2) causes premature packing wear and leaking. Check these parts by rubbing a finger on the surface and by holding the parts up to the light at a slight angle.
Use light, waterproof grease wherever grease is mentioned.
11 309407

This pump has an adjustable piston ball check.
To change the piston ball travel, loosen the locknut (4). Turn the piston valve housing (14) counterclockwise to increase and clockwise to decrease. Medium viscosity fluids should have a 3/16 in. (5 mm) ball travel. Decreasing the ball travel minimizes surging at stroke changeover; however, too short of ball travel restricts the flow and slows down the pump.
12 309407

13 309407


14 309407

Model 965124, Series B stubby length
Model 965129, Series B 400 lb. (180 Kg) drum length
Ref No. Part No. Description Qty.
Ref No. Part No. Description Qty.
1 AIR MOTOR 1 2 183010 CYLINDER, pump, displacement
30 603778 PACKING, foot valve 2 31 222308 ADAPTER, bung; 2 in. npt
(model 965124 only) 1 160917 CYLINDER, pump, displacement
(model 965129 only) 1 33* 154662 O-RING 1 34* 171590 SPREADER, cup 2 35* 171594 WASHER, piston 2 36* 158402 CUP; leather 2
(model 965129 only) 1 3 624936 ROD, connecting (for 965124) 1 624952 ROD, connecting (for 965129) 1 4 100111 NUT 1 5 624943 BEARING, rod guide, 10:1 shovel 1 6 624938 POPPET, foot valve 1 7 624935 VALVE, foot 1 8 624937 ROD, priming 1 9 624939 PLATE, priming; aluminum 1 10 100077 NUT, hex 1 11 156633 O-RING 1 12 100103 PIN, cotter 1 13 156641 O-RING 1 14 624941 HOUSING, valve 1 15 100279 BALL, metallic 1 16 624942 HOUSING, valve piston 1 20 158857 SPACER, cup 1
* These parts are included in Repair Kit 237498, which may be purchased separately. See Graco Manual 306982 to order replacement air motor parts. Air motor 205647 is identical to the one on 965124 and 965129 with the following exceptions:
205647 Ref No. Part No. Description
32 15E954 CYLINDER, motor, air 34 15F982 BASE, motor, air 36 15E555 PLATE, identification 53 116343 SCREW, ground 54 omitted NO WASHER, tab
15 309407

1” npt(f) Fluid Outlet
14 .6 in. (371 mm)
6.5 in. (165 mm) Diameter
28.5 in.
1/2 npt(f) Air Inlet
13.9 in.
50.8 in. 1290 mm)
37.3 in. (947.4 mm)
Mounting Hole Layout
3 1/4” (82.6 mm) DIA. TWO 5/16” (7.94 mm) DIAMETER HOLES ON 4 1/4” (108 mm) BOLT CIRCLE
2–3/32” (53.18 mm) 45o
7/8” (22.2 mm) DIA.

Fluid pressure ratio 10:1 Air pressure operating range 40–180 psi (0.3–1.2 MPa, 3–12.4 bar) Maximum working pressure 1800 psi (12.4 MPa, 124 bar) Maximum delivery 5.2 gpm (19.7 lpm) Cycles per gallon (per liter) 20 (6) Max. recommended pump speed 60 cycles per minute Air motor effective diameter 4.25 in (108 mm) Stroke 4 in. (102 mm) Air consumption approx. 13 cfm per gallon (6 m/hr/liter)
of fluid at 100 psi (0.7 MPa, 7 bar) Wetted parts steel, brass, aluminum, leather, Buna–N Weight 38 lb (17 kg)
Sound Pressure Level (measured at 1 meter from unit)
Input Air Pressures at 15 cycles per minute
40 psi (0.28 MPa, 2.8 bar) 70 psi (0.48 MPa, 4.8 bar) 100 psi (0.7 MPa, 7 bar)
73.6 dB(A) 78.34 dB(A) 80.85 dB(A)
Sound Power Level (tested in accordance with ISO 9614–2)
Input Air Pressures at 15 cycles per minute
40 psi (0.28 MPa, 2.8 bar) 70 psi (0.48 MPa, 4.8 bar) 100 psi (0.7 MPa, 7 bar)
87.4 dB(A) 92.09 dB(A) 94.62 dB(A)
17 309407

Graco warrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written recommendations.
This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco.
This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.
THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.
Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.
Graco makes no warranty, and disclaims all implied warranties of merchantability and fitness for a particular purpose in connection with accessories, equipment, materials or components sold but not manufactured by Graco. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these warranties.
In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the negligence of Graco, or otherwise.
FOR GRACO CANADA CUSTOMERS The parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés à la suite de ou en rapport, directement ou indirectement, avec les procedures concernées.
TO PLACE AN ORDER, contact your Graco distributor, or call one of the following numbers
to identify the distributor closest to you:
1–800–533–9655 Toll Free 612–623–6928 612–378–3590 Fax
All written and visual data contained in this document reflects the latest product information available at the time of publication.
Graco reserves the right to make changes at any time without notice.
This manual contains English. MM 309407 Graco Headquarters: Minneapolis International Offices: Belgium, Korea, China, Japan
18 309407
Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| Pump fails to operate. | Inadequate air supply pressure or restricted air lines | Increase air supply; clear | p.8 |
| Pump fails to operate. | Closed or clogged valves | Open; clean | p.8 |
| Pump fails to operate. | Clogged fluid lines, hoses, valves, etc. | Clear* | p.8 |
| Pump fails to operate. | Damaged air motor | Service air motor | p.8 |
| Pump fails to operate. | Exhausted fluid supply | Refill and reprime, or flush | p.8 |
| Continuous air exhaust | Worn or damaged air motor gasket, packing, seal, etc. | Service air motor | p.8 |
| Erratic pump operation | Exhausted fluid supply | Refill and reprime, or flush | p.8 |
| Erratic pump operation | Held open or worn intake valve or piston packings | Clear; service | p.8 |
| Pump operates, but output low on upstroke | Held open or worn piston or packings | Clear; service | p.8 |
| Pump operates, but output low on downstroke | Held open or worn intake valve | Clear; service | p.8 |
| Pump operates, but output low on both strokes | Inadequate air supply or restricted air lines | Increase air supply; clear | p.8 |
| Pump operates, but output low on both strokes | Closed or clogged valves | Open; clean | p.8 |
| Pump operates, but output low on both strokes | Exhausted fluid supply | Refill and reprime, or flush | p.8 |
| Pump operates, but output low on both strokes | Clogged fluid lines, hoses, valves, etc. | Clear* | p.8 |
| Pump operates, but output low on both strokes | Loose packing nut or worn packings | Tighten; replace | p.8 |
Owners and our team usually reply within a day — and your question helps the next person too.