3:1 Ratio President Pump
307674R
Used for transfer, supply, and recirculation of compatible fluids. For professional use only.
360 psi (2.5 MPa, 25 bar) Maximum Fluid Working Pressure 120 psi (0.8 MPa, 8.3 bar) Maximum Air Input Pressure
* Part No. 218747, Series C Stainless Steel, Stubby Size, UHMWPE and Leather Packed
* Part No. 237142, Series A Carbon Steel, Stubby Size, Leather Packed with PTFE Backup
* Part No. 237143, Series A Carbon Steel, Stubby Size, Leather and PTFE Packed
* Part No. 237146, Series A Stainless Steel, Stubby Size, PTFE Packed
** Part No. 218795, Series C Stainless Steel, 55 Gallon (200 Liter) Drum Size, UHMWPE and Leather Packed
** Part No. 237144, Series A Carbon Steel, 55 Gallon (200 Liter) Drum Size, Leather Packed with PTFE Backup
Part No. 237145, Series A Stainless Steel, 55 Gallon (200 Liter) Drum Size, PTFE Packed
*This model is
T6
**This model is
ITS03ATEX11228
Model 218747 Shown


Equipment misuse can cause the equipment to rupture or malfunction and result in serious injury.
This equipment is for professional use only.
Read all instruction manuals, tags, and labels before operating the equipment.
Use the equipment only for its intended purpose. If you are not sure, call your Graco distributor.
Do not alter or modify this equipment.
Check equipment daily. Repair or replace worn or damaged parts immediately.
Do not exceed the maximum working pressure of the lowest rated system component. Refer to the Technical Data on page 17 for the maximum working pressure of this equipment.
Use fluids and solvents which are compatible with the equipment wetted parts. Refer to the Tech- nical Data section of all equipment manuals. Read the fluid and solvent manufacturer’s warnings.
Do not use 1,1,1–trichloroethane, methylene chloride, other halogenated hydrocarbon solvents or fluids containing such solvents in aluminum equipment. Such use could result in a serious chemical reaction, with the possibility of explosion.
Do not use hoses to pull equipment.
Route hoses away from traffic areas, sharp edges, moving parts, and hot surfaces. Do not expose Graco hoses to temperatures above 82C (180F) or below –40C (–40F).
Wear hearing protection when operating this equipment.
Do not lift pressurized equipment.
Comply with all applicable local, state, and national fire, electrical, and safety regulations.
307674 3

4 307674

Z
W
Fig. 2 is only a guide for selecting and installing sys- tem components and accessories. Contact your Graco distributor for assistance in designing a system to suit your particular needs.
All persons who operate the equipment must be trained in the safe, efficient operation of all system components as well as the proper handling of all fluids. All operators must thoroughly read all instruction manuals, tags, and labels before operating the equip- ment.
FIRE AND EXPLOSION HAZARD Before operating the pump, ground the system as explained below. Also read the section FIRE AND EXPLOSION HAZARD on page 4.
Mount the pump to suit the type of installation planned. The pump dimensions and mounting hole layout are shown on page 16.
If the pump is immersed, be sure the pump intake is 1/2 in. (13 mm) off the bottom of the fluid container.
If the pump is mounted on the wall or on a stand, connect a suction line to the pump’s 1–1/2” npt(f) fluid inlet and place the other end of the line in the fluid container.
307674 5

A Bleed-Type Master Air Valve (required, for pump) B Air Filter/Regulator C Air Line Lubricator D Fluid Drain Valve (required) E Surge Tank
F Fluid Shutoff Valves G Fluid Filter H Fluid Pressure Regulator J Air Spray Gun K Back Pressure Regulator L Pump
M Air Supply Line N Bleed-Type Master Air Valves (for accessories) P Main Fluid Supply Line R Pump Runaway Valve
S Main Fluid Return Line T Secondary Fluid Return Line Y Ground Wire (required; see page 5 for installation instructions)
N
H
F
M
N
M
B
P
J
Y
L M
F
E F G
R
K
F
K
F
F
T
D
A
S
6 307674

A fluid drain valve (D) is required in your system to help reduce the risk of serious injury, including splashing of fluid in the eyes or on the skin.
A bleed-type master air valve (A) is required in your system to help reduce the risk of serious injury, including splashing of fluid in the eyes or on the skin, and injury from moving parts if you are adjust- ing or repairing the pump.
The fluid drain valve assists in relieving fluid pres- sure in the displacement pump, hose, and gun. Triggering the gun to relieve pressure may not be sufficient.
The bleed-type master air valve relieves air trapped between this valve and the pump after the air is shut off. Trapped air can cause the pump to cycle unexpectedly. Locate the valve close to the pump.
The fluid drain valve (D) is required in your sys- tem to relieve fluid pressure in the hose and gun (see the WARNING above).
Install a surge tank (E) to reduce fluid line pulsa- tions.
The bleed-type master air valve (A) is required in your system to relieve air trapped between it and the air motor when the valve is closed (see the WARNING above). Be sure the bleed valve is easily accessible from the pump, and is located downstream from the air filter/regulator (B). Order Part No. 113269 Bleed Valve.
Install two fluid filters (G) to remove impurities from the fluid before it reaches the spray gun (J). Install fluid shutoff valves (F) upstream and down- stream from each filter; this arrangement enables you to continue spraying while cleaning a filter.
The air filter/regulator (B) controls pump speed and outlet pressure by adjusting the air pressure to the pump and the air spray gun. It also removes harmful dirt and moisture from the compressed air supply. Locate the pump air filter/regulator up- stream from the pump’s bleed-type master air valve (A). Also, supply an air filter/regulator at each spray booth.
Install a fluid pressure regulator (H) to provide precise fluid pressure control at each spray booth.
Install fluid shutoff valves (F) where shown.
Install a main fluid return line (S) to circulate fluid back to the pump’s return port.
A pump runaway valve (R) automatically shuts off the pump if it starts running too fast. A pump which runs too fast can be seriously damaged.
Install a secondary fluid return line (T) to circu- late fluid from the spray guns back to the fluid supply container.
An air line lubricator (C) provides automatic air motor lubrication. Install downstream from the pump air filter/regulator (B).
Install a back pressure regulator (K) on each fluid return line, after the last gun station, to provide constant system back pressure for all spray guns and proper pressure for fluid circulation.
Install additional air bleed valves (N) at each air line drop, to isolate accessories for servicing.

If the pump is not immersed, fill the packing nut/wet- cup 1/2 full with a compatible solvent. Keep the cup filled at all times to help prevent the fluid you are pumping from drying on the exposed displacement rod and damaging the throat packings.
PRESSURIZED EQUIPMENT HAZARD The system pressure must be manually relieved to prevent the system from starting or spraying acci- dentally. To reduce the risk of an injury from acci- dental spray from the gun, splashing fluid, or moving parts, follow the Pressure Relief Proce- dure whenever you:
The pump is tested with lightweight oil, which is left in to protect the pump parts. If the fluid you are using may be contaminated by the oil, flush it out with a compatible solvent. See Flushing on page 10.
are instructed to relieve the pressure, stop spraying, check or service any of the system equipment, or install or clean the spray nozzle.
If you suspect that the spray nozzle or hose is com- pletely clogged, or that pressure has not been fully relieved after following the steps above, very slowly loosen the nozzle retaining ring or hose end coupling and relieve pressure gradually, then loosen completely. Now clear the nozzle or hose.
Packing Nut
To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure at left.
Check the tightness of the packing nut/wet-cup (U) periodically. The nut should be tight enough to prevent leakage. Torque the nut to 20–24 ft-lb (27–33 N.m); do not overtighten or you may damage the packings. Relieve pressure before adjusting the nut. See Fig. 3.
06110 Fig. 3
Model 218747 Shown · 8 307674

To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 8.
COMPONENT RUPTURE HAZARD To reduce the risk of overpressurizing your system, which could cause compo- nent rupture and serious injury, never exceed 120 psi (8 bar) air supply pressure to the pump.
Do not allow the pump to run dry. It will quickly accelerate to a high speed, causing damage. If your pump is running too fast, stop it immediately and check the fluid supply. If the container is empty and air has been pumped into the lines, refill the con- tainer and prime the pump and the lines, or flush and leave it filled with a compatible solvent. Eliminate all air from the fluid system.
In a circulating system, the pump will run continu- ously and slow down or speed up on demand, until the air supply is shut off.
In a direct supply system, with adequate air pres- sure supplied to the motor, the pump will start and stop as you open and close the gun.
307674 9

CAUTION
Never leave water or water-base fluid in the pump overnight. If you are pumping water-base fluid, flush with water first, then with a rust inhibitor such as mineral spirits. Relieve the pressure, but leave the rust inhibitor in the pump to protect the parts from corrosion.
To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 8.
For overnight shutdown, stop the pump at the bottom of its stroke to prevent fluid from drying on the ex- posed displacement rod and damaging the throat packings. Relieve the pressure.
To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 8.
Always flush the pump before the fluid dries on the displacement rod. See Flushing below.
FIRE AND EXPLOSION HAZARD Before flushing, read the section FIRE AND EXPLOSION HAZARD on page 4. Be sure the entire system and flush- ing pails are properly grounded. Refer to Grounding on page 5.
Flush the pump:
Before the first use
When changing colors or fluids
Water, or even moist air, can cause your pump to corrode. To help prevent corrosion, never leave the pump filled with water or air. Follow the instructions under Flushing, at left.
Before fluid can dry or settle out in a dormant pump (check the pot life of catalyzed fluids)
Before storing the pump.
Flush with a fluid that is compatible with the fluid you are pumping and with the wetted parts in your system. Check with your fluid manufacturer or supplier for recommended flushing fluids and flushing frequency.
The fluid piston and intake valves are factory set for pumping medium viscosity fluids. See the separate displacement pump manual, 307652, for adjustment procedures to pump lighter or heavier viscosity fluids.
10 307674

To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 8.
* To determine if the fluid hose or gun is obstructed, follow the Pressure Relief Procedure on page 8. Discon- nect the fluid hose and place a container at the pump fluid outlet to catch any fluid. Turn on the air just enough to start the pump (about 20–40 psi [1.4–2.8 bar]). If the pump starts when the air is turned on, the obstruction is in the fluid hose or gun.
307674 11

Reconnecting the Displacement Pump
To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 8.
If you are removing the mounting tubes, wrench the tubes close to the motor base to prevent thread damage in the base. Use thread sealant on the male threads when reinstalling.
12 307674

Torque to 65–75 ft-lb (88–102 N.m).
Apply thread sealant.
Lubricate.
S
06108 Fig. 4
Model 218747 Shown · 307674 13

Model 218747, Series C 3:1 Ratio President Pump, Stubby Size; UHMWPE and Leather Packed
Model 237142, Series A 3:1 Ratio President Pump, Stubby Size; Leather Packed with PTFE Backup
Model 237143, Series A 3:1 Ratio President Pump, Stubby Size; Leather and PTFE Packed
Model 237146, Series A 3:1 Ratio President Pump, Stubby Size; PTFE Packed
Ref Part No. No. Description Qty
1 Used on Models 2218747, 237142, and 237143 only.
2 Used on Model 237146 only.
1 210007 AIR MOTOR, President; used on 218747; see 307157 1 205038 AIR MOTOR, President used on 237142, 237143, and 237146; see 306982 1 2 190116 ROD, connecting; 5.69” (144.5 mm) long 1 3 218746 PUMP, displacement; used on 218747; see 307652 1 237140 PUMP, displacement; used on 237142; see 307652 1 237141 PUMP, displacement; used on 237143; see 307652 1 237199 PUMP, displacement; used on 237146; see 307652 1 4 100579 PIN, cotter 1 6 156082 O-RING; nitrile rubber 1 8 166443 NIPPLE, hex, reducing; 3/4 x 1/2 npt 1 10 180986 TUBE, return; 12.812” (325.4 mm) long 1 11 189215 TUBE, supply; 6.75” (171.5 mm) long; used on 218747, 237142, and 237143 only 1 112919 TUBE, supply; 1” npt(f) fluid outlet; 6.75” (171.5 mm) long; used on 237146 only 1 12 118160 LOCKWASHER, ext shakeproof 2 13 171217 NUT, lock; 3/4–11 2 14 171439 NIPPLE, hex, reducing; 1” x 3/4 npt 1 15 158256 UNION; straight adapter; 1/2 npt(m) x 3/8 npsm(f) 1 20 190117 NUT, coupling 1 21 190119 COLLAR, coupling 2
14 307674

Model 218795, Series C 3:1 Ratio President Pump, 55 Gallon (200 Liter) Drum Size; UHMWPE and Leather Packed
Model 237144, Series A 3:1 Ratio President Pump, 55 Gallon (200 Liter) Drum Size; Leather Packed with PTFE Backup
Model 237145, Series A 3:1 Ratio President Pump, 55 Gallon (200 Liter) Drum Size; PTFE Packed
1 Used on Models 237144 and 237145 only.
2 Used on Model 218795 only (not shown).
3 Used on Models 218795 and 237144 only.
Ref Part No. No. Description Qty
4 Used on Model 237145 only.
1 210007 AIR MOTOR, President; used on 218795; see 307157 1 205038 AIR MOTOR, President; used on 237144 and 237145; see 306982 1 2 190115 ROD, connecting; 18.25” (463.6 mm) long 1 3 218746 PUMP, displacement; used on 218795; see 307652 1 237140 PUMP, displacement; used on 237144; see 307652 1 237199 PUMP, displacement; used on 237145; see 307652 1 4 100579 PIN, cotter 1 6 156082 O-RING; nitrile rubber 1 7 100081 BUSHING; 1/2 npt(m) x 3/8 npt(f); used on 218795 only 1 8 160032 NIPPLE; 3/4 npt 1 10 180990 TUBE, return; 25.375” (644.5 mm) long 1 11 189216 TUBE, supply; 19.312” (490.52 mm) long; used on 218795 and 237144 only 1 112918 TUBE, supply; 1” npt(f) fluid outlet; 19.312” (490.52 mm) long; used on 237145 only 1 12 118160 LOCKWASHER, ext shakeproof 2 13 171217 NUT, lock; 3/4–11 2 15 158256 UNION; straight adapter; 1/2 npt(m) x 3/8 npsm(f); used on 237144 and 237145 only 1 20 190117 NUT, coupling 1 21 190119 COLLAR, coupling 2
15 or 7 · 307674 15

Mounting Hole
Layout
0.375” (9.52 mm)
2.254” (57.25 mm)
2.254” (57.25 mm)
3.188” (80.97 mm)
2.625” (66.67 mm)
5.250” (133.4 mm)
1” npt(f) outlet 3/4 npt(f) return
Model No. A B C
218795 48.88 in. (1242 mm)
16.38 in. (416 mm)
32.5 in. (826 mm)
237144, 237145 48.95 in. (1244 mm)
16.45 in. (418 mm)
32.5 in. (826 mm)
218747 36.38 in. (924 mm)
16.38 in. (416 mm)
20 in. (508 mm)
36.45 in. (926 mm)
16.45 in. (418 mm)
20 in. (508 mm)
diameter · 237142, 237143, 237146 · 16 307674

Ratio 3:1
Maximum fluid working pressure 360 psi (2.5 MPa, 25 bar)
Maximum air input pressure 120 psi (0.8 MPa, 8.3 bar)
Pump cycles per 1 gallon (3.8 liters) 6
Fluid flow at 60 cycles per minute 10 gpm (38 liters/min)
Fluid inlet size 1–1/2 npt(f)
Fluid outlet size 1 in. npt(f)
Air inlet size 3/8 npsm(f)
Weight 47 lb (21.32 kg)
Maximum pump operating temperature 180F (82C)
* Sound level at 100 psi, 60 cycles per minute 94 dBa
* Sound power level at 100 psi, 60 cycles per minute 109 dBa
Wetted parts Supply and Return Tubes: Stainless steel Air Motor Base: Aluminum Displacement Pump: Refer to manual 307652
* Tested in accordance with ISO 3744.
A 100 psi (7 bar) air pressure B 70 psi (4.9 bar) air pressure C 40 psi (2.8 bar) air pressure
Fluid Outlet Pressure Chart Air Consumption Chart
cycles per min 15 30 45 60 bar
cycles per min 15 30 45 60
AIR CONSUMPTION
A
A
B B
0.0 2.5 5.0 7.5 10.0 0
0.0 2.5 5.0 7.5 10.0
9.5 19 29 38 liters/min
9.5 19 29 38 liters/min
FLUID FLOW (TEST FLUID: NO 10 MOTOR OIL)
To find Fluid Outlet Pressure (bar/psi) at a specific fluid flow (lpm/ gpm) and operating air pressure (bar/psi):
To find Pump Air Consumption (m/min or scfm) at a specific fluid flow (lpm/gpm) and operating air pressure (bar/psi):

Graco warrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written recommendations.
This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or sub- stitution of non–Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco.
This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.
THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.
Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.
Graco makes no warranty, and disclaims all implied warranties of merchantability and fitness for a particular purpose in connection with accessories, equipment, materials or components sold but not manufactured by Graco. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these warranties.
In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the negligence of Graco, or otherwise.
FOR GRACO CANADA CUSTOMERS The parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnais- sent avoir convenu que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés à la suite de ou en rapport, directement ou indirectement, avec les procedures concernées.
For the latest information about Graco products, visit www.graco.com For patent information, see www.graco.com/patents
TO PLACE AN ORDER, contact your Graco distributor or call to identify the distributor closest to you: Phone: 612–623–6921 or Toll Free: 1–800–328–0211 Fax: 612–378–3505
All written and visual data contained in this document reflects the latest product information available at the time of publication.
Graco reserves the right to make changes at any time without notice.
Original instructions. This manual contains English. MM 307674
GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440–1441 Copyright 1985, Graco Inc. is registered to ISO 9001
www.graco.com Revision R, July 2013
18 307674
Pages referenced in this manual — manufacturer, support and downloads.
Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| Pump fails to operate. | Restricted line or inadequate air supply. | Clear; increase air supply. | p.11 |
| Pump fails to operate. | Dirty or damaged air motor. | Service air motor (see 306982 or 307157). | p.11 |
| Pump fails to operate. | Clogged fluid hose, gun, or nozzle. | Clear.* | p.11 |
| Pump operates but output is low on both strokes. | Restricted line or inadequate air supply. | Clear; increase air supply. | p.11 |
| Pump operates but output is low on both strokes. | Exhausted fluid supply. | Refill; reprime or flush. | p.11 |
| Pump operates but output is low on both strokes. | Clogged fluid hose, gun, or nozzle. | Clear.* | p.11 |
| Pump operates but output is low on both strokes. | Loose packing nut or worn throat packings. | Tighten packing nut (see page 8); replace throat packings. | p.11 |
| Pump operates but output is low on both strokes. | Piston and intake valves need ad- justment. | Adjust; see manual 307652. | p.11 |
| Pump operates but output is low on downstroke. | Held open or worn intake valve. | Clear; service. See manual 307652. | p.11 |
| Pump operates but output is low on upstroke. | Held open or worn fluid piston valve or packings. | Clear; service. See manual 307652. | p.11 |
| Erratic or accelerated operation. | Exhausted fluid supply. | Refill; reprime or flush. | p.11 |
| Erratic or accelerated operation. | Piston and intake valves need ad- justment. | Adjust; see manual 307652. | p.11 |
| Erratic or accelerated operation. | Held open or worn intake valve. | Clear; service. See manual 307652. | p.11 |
| Erratic or accelerated operation. | Held open or worn fluid piston valve or packings. | Clear; service. See manual 307652. | p.11 |
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.