EN
Graco logo
Official user manual

Graco Air Regulator (220-569)

48 pages·819 KB·Heat Pump·PDF·ENDEFRITNLJA
Graco Air Regulator (220-569)
Table of Contents 80 sections INSTRUCTIONS-PARTS LIST · 307–809 · Rev. T Supersedes N · and PCN R (includes Rev . S · … ShowHide
INSTRUCTIONS-PARTS LISTp.1307–809p.1Rev. T Supersedes Np.1and PCN R (includes Rev . Sp.1changes)p.1LOW PRESSURE, MEDIUM VOLUME HIGH-FLO Pumpsp.1Model 220–569 Shownp.1Table of Contentsp.2Pump Modelsp.3CARBON STEEL MODELSp.3SEVERE-DUTY ELECTROPOLISHED STAINLESS STEEL MODELSp.3Symbolsp.4Warning Symbolp.4Caution Symbolp.4WARNINGp.4CAUTIONp.4FIRE AND EXPLOSION HAZARDp.5TOXIC FLUID HAZARDp.5Notesp.6Installation (All Pumps)p.7Typical Installationp.7Mount the Pumpp.7Plumbingp.7Groundingp.7Installation (Air-Powered Pumps)p.8Air Line to Motorp.8Fluid Line from Pumpp.8KEYp.9C Dp.9Installation (Hydraulic-Powered Pumps)p.10Hydraulic Power Supplyp.10Hydraulic Return from Motorp.10Hydraulic Supply to Motorp.10K Lp.11Operation (All Pumps)p.12Before Y ou Start the Pumpp.12Flush the Pump Before First Usep.12Pressure Relief Procedurep.12Operation (Air-Powered Pumps)p.13Starting and Adjusting the Pumpp.13Shutdownp.13Operation (Hydraulic-Powered Pumps)p.14Maintenancep.15Excessive Leaking at Throatp.15Flushingp.15Packing Nut Tightnessp.15Air Line Lubricatorp.16Stop the Pump at the Bottom of Its Strokep.16Air Line Filterp.16Hydraulic Power Supply Checkp.16Mix Tank Volumep.16Troubleshootingp.17PROBLEM CAUSE SOLUTIONp.17Servicep.18Disconnecting the Displacement Pumpp.18Reassembling a Motor with an Adapter Platep.18Reconnecting the Displacement Pumpp.18Model 220–569p.19Senator Pumpp.19Shownp.19Model 220–564 President Pump Shownp.19Repair Kitsp.20Disassembling the Displacement Pumpp.20Cleaning and Inspecting Partsp.20Model 220–555 Severe–Duty Electropolished Stainless Steel Pump Shownp.21INLETp.21Reassembling the Displacement Pumpp.22Parts (President Pumps)p.24CARBON STEEL PUMPSp.24SEVERE-DUTY, ELECTROPOLISHED STAINLESS STEEL PUMPSp.24Model 220–559, Series A, 1.5:1 Ratiop.24Model 220–562, Series A, 1.5:1 Ratiop.24Model 220–563, Series A, 2:1 Ratiop.24Model 220–560, Series A, 2:1 Ratiop.24Model 220–564, Series A, 3:1 Ratiop.24Model 220–561, Series A, 3:1 Ratiop.24Model 239–819, Series A, 3:1 Ratiop.24Model 237–222, Series A, 3:1 Ratiop.24Model 237–223, Series A, 3:1 Ratiop.24Parts (Quiet Senator Pumps)p.28
Page 1 of the Graco Air Regulator (220-569) user manual — Model 220–569 Shown
Page 1 · click to enlarge
Page 1

INSTRUCTIONS-PARTS LIST

307–809

Graco Air Regulator (220-569) — INSTRUCTIONS-PARTS LIST diagram (page 1)
Fig. 1

Rev. T Supersedes N

This manual contains important warnings and information. READ AND KEEP FOR REFERENCE.

and PCN R (includes Rev . S

quality counts.

changes)

LOW PRESSURE, MEDIUM VOLUME HIGH-FLO Pumps

Graco Air Regulator (220-569) — changes) diagram (page 1)
Fig. 2 · changes)

Refer to page 2 for the Table of Contents.

For Pump Model Nos., Ratios and Working Pressures, refer to page 3.

Model 220–569 Shown

GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440–1441 COPYRIGHT 1987, GRACO INC. Graco Inc. is registered to I.S. EN ISO 9001

First choice when · Patent Pending

Page 2 of the Graco Air Regulator (220-569) user manual — Table of Contents
Page 2 · Contents
Contents

Contents

INSTRUCTIONS-PARTS LISTp.1307–809p.1Rev. T Supersedes Np.1and PCN R (includes Rev . Sp.1changes)p.1LOW PRESSURE, MEDIUM VOLUME HIGH-FLO Pumpsp.1Model 220–569 Shownp.1Table of Contentsp.2Pump Modelsp.3CARBON STEEL MODELSp.3SEVERE-DUTY ELECTROPOLISHED STAINLESS STEEL MODELSp.3Symbolsp.4Warning Symbolp.4Caution Symbolp.4WARNINGp.4CAUTIONp.4FIRE AND EXPLOSION HAZARDp.5TOXIC FLUID HAZARDp.5Notesp.6Installation (All Pumps)p.7Typical Installationp.7Mount the Pumpp.7Plumbingp.7Groundingp.7Installation (Air-Powered Pumps)p.8Air Line to Motorp.8Fluid Line from Pumpp.8KEYp.9C Dp.9Installation (Hydraulic-Powered Pumps)p.10Hydraulic Power Supplyp.10Hydraulic Return from Motorp.10Hydraulic Supply to Motorp.10K Lp.11Operation (All Pumps)p.12Before Y ou Start the Pumpp.12Flush the Pump Before First Usep.12Pressure Relief Procedurep.12Operation (Air-Powered Pumps)p.13Starting and Adjusting the Pumpp.13Shutdownp.13Operation (Hydraulic-Powered Pumps)p.14Maintenancep.15Excessive Leaking at Throatp.15Flushingp.15Packing Nut Tightnessp.15Air Line Lubricatorp.16Stop the Pump at the Bottom of Its Strokep.16Air Line Filterp.16Hydraulic Power Supply Checkp.16Mix Tank Volumep.16Troubleshootingp.17PROBLEM CAUSE SOLUTIONp.17Servicep.18Disconnecting the Displacement Pumpp.18Reassembling a Motor with an Adapter Platep.18Reconnecting the Displacement Pumpp.18Model 220–569p.19Senator Pumpp.19Shownp.19Model 220–564 President Pump Shownp.19Repair Kitsp.20Disassembling the Displacement Pumpp.20Cleaning and Inspecting Partsp.20Model 220–555 Severe–Duty Electropolished Stainless Steel Pump Shownp.21INLETp.21Reassembling the Displacement Pumpp.22Parts (President Pumps)p.24CARBON STEEL PUMPSp.24SEVERE-DUTY, ELECTROPOLISHED STAINLESS STEEL PUMPSp.24Model 220–559, Series A, 1.5:1 Ratiop.24Model 220–562, Series A, 1.5:1 Ratiop.24Model 220–563, Series A, 2:1 Ratiop.24Model 220–560, Series A, 2:1 Ratiop.24Model 220–564, Series A, 3:1 Ratiop.24Model 220–561, Series A, 3:1 Ratiop.24Model 239–819, Series A, 3:1 Ratiop.24Model 237–222, Series A, 3:1 Ratiop.24Model 237–223, Series A, 3:1 Ratiop.24Parts (Quiet Senator Pumps)p.28
Page 3 of the Graco Air Regulator (220-569) user manual — SEVERE-DUTY ELECTROPOLISHED STAINLESS STEEL MODELS
Page 3 · click to enlarge
Page 3

Pump Models

CARBON STEEL MODELS

Model No.SeriesRatio and Type (parts list pages)Maximum Air (or Hydraulic*) Working PressureMaximum Fluid Working Pressure MPa, bar (psi)MPa, bar (psi) 220–559A1.5:1 President (24)1.2, 12 (180)1.9, 19 (270) 220–560A2:1 President (24)1.2, 12 (180)2.5, 25 (360) 220–561A3:1 President (24)1.1, 11 (166)3.4, 34 (500) 237–223A3:1 President, w/PTFE packings (24)1.1, 11 (166)3.4, 34 (500) 220–574B3:1 President with drum cover, agitator, and return tube (26, 27)1.1, 11 (166)3.4, 34 (500) 220–565A3.5:1 Quiet Senator (28)0.7, 7.0 (100)2.4, 24 (350) 220–566A5:1 Quiet Senator (28)0.7, 7.0 (100)3.4, 34 (500) 220–567A2.5:1 Quiet Senator (28)0.7, 7.0 (100)1.7, 17 (250) 220–577A4:1 Quiet Bulldog (29)0.7, 7.0 (100)2.8, 28 (400) 236–601AViscount I+ (31)10.3, 103 (1500)*3.1, 31 (450) 236–605AViscount I+ (31)10.3, 103 (1500)*2.1, 21 (300) 236–712AViscount I+ (31)10.3, 103 (1500)*1.5, 15 (225)

SEVERE-DUTY ELECTROPOLISHED STAINLESS STEEL MODELS

Model No.SeriesRatio and Type (parts list pages)Maximum Air (or Hydraulic*) Working PressureMaximum Fluid Working Pressure MPa, bar (psi)MPa, bar (psi) 220–562A1.5:1 President (24)1.2, 12 (180)1.9, 19 (270) 220–563A2:1 President (24)1.2, 12 (180)2.5, 25 (360) 220–564A3:1 President (24)1.1, 11 (166)3.4, 34 (500) 239–819A3:1 President (24)1.1, 11 (166)3.4, 34 (500) 237–222A3:1 President, w/PTFE packings (24)1.1, 11 (166)3.4, 34 (500) 220–575B3:1 President with drum cover, agitator, and return tube (26, 27)1.1, 11 (166)3.4, 34 (500) 220–568A3.5:1 Quiet Senator (28)0.7, 7.0 (100)2.4, 24 (350) 220–569A5:1 Quiet Senator (28)0.7, 7.0 (100)3.4, 34 (500) 220–570A2.5:1 Quiet Senator (28)0.7, 7.0 (100)1.7, 17 (250) 220–578A4:1 Quiet Bulldog (29)0.7, 7.0 (100)2.8, 28 (400) 239–815A4:1 Quiet Bulldog (29)0.7, 7.0 (100)2.8, 28 (400) 236–602AViscount I+ (31)10.3, 103 (1500)*3.1, 31 (450) 236–606AViscount I+ (31)10.3, 103 (1500)*2.1, 21 (300) 236–713AViscount I+ (31)10.3, 103 (1500)*1.5, 15 (225)

Page 4 of the Graco Air Regulator (220-569) user manual — Warning Symbol
Page 4 · click to enlarge
Page 4

Symbols

Warning Symbol

Caution Symbol

WARNING

CAUTION

This symbol alerts you to the possibility of serious injury or death if you do not follow the instructions.

This symbol alerts you to the possibility of damage to or destruction of equipment if you do not follow the instructions.

WARNING INSTRUCTIONSEQUIPMENT MISUSE HAZARD Equipment misuse can cause the equipment to rupture or malfunction and result in serious injury. This equipment is for professional use only. Read all instruction manuals, tags, and labels before operating the equipment. Use the equipment only for its intended purpose. If you are uncertain about usage, call your Graco distributor. Do not alter or modify this equipment. Use only genuine Graco parts and accessories. Check equipment daily. Repair or replace worn or damaged parts immediately. Do not exceed the maximum working pressure stated on the equipment or in the Technical Data for your equipment. Do not exceed the maximum working pressure of the lowest rated component in your system. Use fluids and solvents which are compatible with the equipment wetted parts. Refer to the Technical Data section of all equipment manuals. Read the fluid and solvent manufacturer’s warnings. Do not use hoses to pull equipment. Route hoses away from traffic areas, sharp edges, moving parts, and hot surfaces. Do not expose Graco hoses to temperatures above 82C (180F) or below –40C (–40F). Wear hearing protection when operating this equipment. Do not lift pressurized equipment. Comply with all applicable local, state, and national fire, electrical, and safety regulations. MOVING PARTS HAZARD Moving parts, such as the air motor piston, can pinch or amputate your fingers. Keep clear of all moving parts when starting or operating the pump. Before servicing the equipment, follow the Pressure Relief Procedure on page 12 to prevent the equipment from starting unexpectedly.

Page 5 of the Graco Air Regulator (220-569) user manual — TOXIC FLUID HAZARD
Page 5 · click to enlarge
Page 5

WARNING

FIRE AND EXPLOSION HAZARD

Improper grounding, poor ventilation, open flames or sparks can cause a hazardous condition and re- sult in a fire or explosion and serious injury.

Ground the equipment and the object being sprayed. Refer to Grounding on page 7.

If there is any static sparking or you feel an electric shock while using this equipment, stop spray- ing/dispensing immediately. Do not use the equipment until you identify and correct the problem.

Provide fresh air ventilation to avoid the buildup of flammable fumes from solvents or the fluid be- ing sprayed/dispensed.

Keep the spray/dispense area free of debris, including solvent, rags, and gasoline.

Electrically disconnect all equipment in the spray/dispense area.

Extinguish all open flames or pilot lights in the spray/dispense area.

Do not smoke in the spray/dispense area.

Do not turn on or off any light switch in the spray/dispense area while operating or if fumes are present.

Do not operate a gasoline engine in the spray/dispense area.

TOXIC FLUID HAZARD

Hazardous fluid or toxic fumes can cause serious injury or death if splashed in the eyes or on the skin, inhaled, or swallowed.

Know the specific hazards of the fluid you are using.

Store hazardous fluid in an approved container. Dispose of hazardous fluid according to all local, state and national guidelines.

Always wear protective eyewear, gloves, clothing and respirator as recommended by the fluid and solvent manufacturer.

Page 6 of the Graco Air Regulator (220-569) user manual — Notes
Page 6 · click to enlarge
Page 6

Notes

Page 7 of the Graco Air Regulator (220-569) user manual — WARNING
Page 7 · click to enlarge
Page 7

Installation (All Pumps)

Typical Installation

Z

Y

The Typical Installations shown in Figs. 2 and 3, and the following installation information are only guides. Proper sizing of the pump, accessories and lines is essential to get the maximum performance from your system. Contact your Graco distributor for assistance in designing a system to meet your needs.

Mount the Pump

This pump can be mounted on a floor stand, cart, wall bracket, or drum. The floor stand shown in the Typical Installation is Part. No. 220–581.

W

Instructions for mounting the pump are supplied with the mounting accessory.

2. Air and fluid hoses: use only electrically conductive hoses.

Plumbing

The pump has a 1–1/2 in. npt(f) fluid inlet and a 1 in. npt(f) fluid outlet. Use a minimum 25 mm (1 in.) diame- ter pipe or hose between the pump outlet and any supply line accessories. Use a minimum 38 mm (1–1/2 in.) diameter pipe or hose between the mix tanks and pump inlet.

3. Air compressor or hydraulic power supply: follow manufacturer’ s recommendations.
4. Surge tank: use a ground wire and clamp. See Fig. 1.

When using a stainless steel pump, use stainless steel plumbing to maintain a corrosion-resistant system.

5. Spray gun: ground through connection to a prop - erly grounded fluid hose and pump.

Grounding

6. Fluid supply container: follow your local code.

WARNING

7. Object being sprayed: follow your local code.

FIRE AND EXPLOSION HAZARD Before operating the pump, ground the system as explained below. Also read the section FIRE AND EXPLOSION HAZARD on page 5.

8. Solvent pails used when flushing: follow your local code. Use only metal pails, which are conductive, placed on a grounded surface. Do not place the pail on a nonconductive surface, such as paper or cardboard, which interrupts the grounding continu - ity.
1. Pump: use the ground wire and clamp. See Fig. 1. Loosen the grounding lug locknut (W) and washer (X). Insert one end of a 12 ga (1.5 mm ) minimum ground wire (Y) into the slot in lug (Z) and tighten the locknut securely . Connect the other end of the wire to a true earth ground. For a ground wire and clamp, order Part No. 237–569.
9. T o maintain grounding continuity when flushing or relieving pressure, hold a metal part of the spray gun firmly to the side of a grounded metal pail, then trigger the gun.

Page 8 of the Graco Air Regulator (220-569) user manual — Fluid Line from Pump
Page 8 · click to enlarge
Page 8

Installation (Air-Powered Pumps)

Air Line to Motor

5. The air filter (K) removes harmful dirt and moisture from the compressed air supply .

WARNING

6. The air supply line (J) must be large enough to supply the proper volume of air to the motor .

A bleed-type master air valve (D) is required in your system, to help reduce the risk of serious injury including splashing fluid in the eyes or on the skin, and injury from moving parts if you are adjust- ing or repairing the pump.

Fluid Line from Pump

WARNING

The bleed-type master air valve relieves air trapped between this valve and the pump after the air is shut off. Trapped air can cause the pump to cycle unexpectedly. Locate the valve close to the pump. Order Part No. 113–333.

A fluid drain valve (J) is required in your system, to help reduce the risk of serious injury including splashing in the eyes or on the skin if the pump cycles unexpectedly.

Locate one valve downstream from the pump outlet and another valve downstream from the surge tank (G). These drain valves are used to relieve fluid pressure in the pump and surge tank during shut- down.

1. The air line lubricator (N) automatically lubricates the air motor to prevent corrosion. See Fig. 2.
2. The bleed-type master air valve (M) relieves air trapped between itself and the motor , when the valve is closed. Install one valve close to the pump, downstream from the air regulator . Install a second bleed valve upstream from all other air line accessories, to isolate the accessories for servic - ing.
1. The surge tank (G) reduces fluid surging to pre - vent backflow into the pump. Mounting instructions are supplied with the tank.
2. The shutoff valves (D) before and after the surge tank, and between each mix tank and the pump fluid inlet, isolate these components for servicing.
3. The air regulator (L) controls pump speed.
4. The pump runaway valve (P) shuts of f the air to the pump if the pump speed exceeds your pre-ad - justed setting. Running a pump too fast can dam - age it.
3. Be sure the supply line (C) between the pump and mix tanks is level.

Page 9 of the Graco Air Regulator (220-569) user manual — C D
Page 9 · click to enlarge
Page 9

Installation (Air-Powered Pumps)

KEY

A Mix Tank B Pump Stand C Fluid Supply Line; 38 mm (1–1/2 in.) minimum diameter D Fluid Shutoff Valve E Fluid Line; 25 mm (1 in.) minimum diameter F Surge Tank Stand G Surge Tank H Ground Wire (required; see page 7 for installation) J Air Supply Line K Airline Filter L Air Regulator and Gauge M Bleed-Type Master Air Valve (required) N Airline Lubricator P Pump Runaway Control Valve Q Fluid Drain Valve (required)

Graco Air Regulator (220-569) — KEY diagram (page 9)
Fig. 3

C D

D

Page 10 of the Graco Air Regulator (220-569) user manual — Fluid Line from Pump
Page 10 · click to enlarge
Page 10

Installation (Hydraulic-Powered Pumps)

Hydraulic Power Supply

Hydraulic Return from Motor

CAUTION

The Hydraulic Power Supply must be kept clean at all times to avoid damage to the motor and hydraulic power supply.

1. The shutof f valve (R) isolates the motor when servicing the system.
1. Blow out hydraulic lines with air and flush thor - oughly before connection to the motor .

CAUTION

To avoid damage to the pump, never use the return line shutoff valve to control the hydraulic flow. Do not install any flow control devices on the hydraulic re- turn line.

2. Plug hydraulic inlets, outlets, and line ends when disconnecting them for any reason.
1. Be sure the power supply can provide suf ficient power to the motor .
2. The 10 micron size return filter (J) removes resi - due from the hydraulic fluid to help keep the sys - tem running smoothly .
2. Be sure the power supply is equipped with a suction filter to the hydraulic pump.

Fluid Line from Pump

Hydraulic Supply to Motor

WARNING

A fluid drain valve (J) is required in your system, to help reduce the risk of serious injury including splashing in the eyes or on the skin if the pump cycles unexpectedly.

1. The shutof f valve (R) isolates the motor when servicing the system. See Fig. 3.

Locate one valve downstream from the pump outlet and another valve downstream from the surge tank (G). These drain valves are used to relieve fluid pressure in the pump and surge tank during shut- down.

2. The hydraulic fluid pressure gauge (Q) monitors the hydraulic oil pressure to the motor . This helps avoid overpressurizing the motor or displacement pump.
1. The surge tank (G) reduces fluid surging to pre - vent backflow into the pump. Mounting instructions are supplied with the tank.
3. The pressureand temperature-compensated flow control valve (S) prevents the motor from running too fast, which can damage it.
2. The shutoff valves (D) before and after the surge tank, and between each mix tank and the pump fluid inlet, isolate these components for servicing.
4. The pressure reducing valve (P) which has a drain line (M) running to the return line (K), controls the hydraulic pressure to the motor .
3. Be sure the supply line (C) between the pump and mix tanks is level.

Page 11 of the Graco Air Regulator (220-569) user manual — K L
Page 11 · click to enlarge
Page 11

Installation (Hydraulic-Powered Pumps)

KEY

A Mix Tank B Pump Stand C Fluid Supply Line; 38 mm (1–1/2 in.) minimum diameter D Fluid Shutoff Valve

E Fluid Line; 25 mm (1 in.) minimum diameter F Surge Tank Stand G Surge Tank H Ground Wire (required; see page 7 for installation)

J 10 Micron Return Filter K Hydraulic Return Line; 16 mm (5/8 in.) minimum diameter L Hydraulic Supply Line; 13 mm (1/2 in.) minimum diameter M Drain Line

P Pressure Reducing Valve Q Hydraulic Pressure Gauge R Hydraulic Shutoff Valve S Flow Control Valve T Fluid Drain Valve (required)

K L

Graco Air Regulator (220-569) — K L diagram (page 11)
Fig. 4

Page 12 of the Graco Air Regulator (220-569) user manual — Pressure Relief Procedure
Page 12 · click to enlarge
Page 12

Operation (All Pumps)

Before Y ou Start the Pump

1. Shut of f the power to the pump.

Read and follow all instruction manuals, labels and tags supplied with this pump and with all the accesso- ries you add to the system, before operating the sys- tem.

2. In an air-powered system, close the air regulator and close the bleed-type master air valve.
3. In a hydraulic-powered system, close the hy - draulic supply line shutof f valve first, then the return line shutof f valve. In a multi-pump system, do this at each pump to isolate the pumps.

Flush the Pump Before First Use

The pump was tested in lightweight oil. If the oil will contaminate the fluid you are pumping, flush it out with a compatible solvent.

4. Close the fluid shutof f valves from the supply tanks.

Pressure Relief Procedure

WARNING

5. T rigger the gun at the last gun station to relieve fluid pressure. Maintain firm metal-to-metal contact between the gun and a grounded waste pail. Repeat for all gun stations.

PRESSURIZED EQUIPMENT HAZARD The system pressure must be manually relieved to prevent the system from starting or spraying acci- dentally. To reduce the risk of an injury from acci- dental spray from the gun, splashing fluid, or moving parts, follow the Pressure Relief Proce- dure whenever you:

6. Open the pump drain valve to relieve fluid pres - sure which may be trapped in the pump or hose.

are instructed to relieve the pressure, stop spraying, check or service any of the system equipment, or install or clean the spray nozzle.

If you suspect that pressure is not fully relieved after following the steps above, wrap a fitting near the pump outlet with a rag, and slowly and carefully loosen the fitting to relieve pressure. Be careful to protect your eyes from splashing.

Page 13 of the Graco Air Regulator (220-569) user manual — WARNING
Page 13 · click to enlarge
Page 13

Operation (Air-Powered Pumps)

Starting and Adjusting the Pump

1. Charge the surge tank, if you are using one. See the separate instruction manual, 307–707.
2. Open all shutof f valves (D).
3. Open the dispensing valve/spray gun at the last gun station and keep it open while starting the pump.

WARNING

COMPONENT RUPTURE HAZARD To reduce the risk of overpressurizing your system, which could cause component rupture and serious injury, never exceed the specified maximum air input pressure to the pump (see Technical Data on pages 40–45).

4. Open the bleed-type master air valves (M).
5. Adjust the air regulator (L) to the minimum pres - sure necessary for the pump to cycle slowly .
6. When fluid is flowing smoothly from the gun, release the gun trigger .

Shutdown

7. One at a time, open any other guns in the system to purge air from the lines.

WARNING

8. Adjust the pump runaway valve (P) according to the instructions supplied with it.

To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 12.

9. Adjust the lubricator (N) according to the instruc - tions supplied with it.

Relieve the pressure.

Page 14 of the Graco Air Regulator (220-569) user manual — WARNING
Page 14 · click to enlarge
Page 14

Operation (Hydraulic-Powered Pumps)

Starting and Adjusting the Pump

12. Release the gun trigger .
1. Charge the surge tank, if you are using one. See the separate instruction manual, 307–707.
2. Open all shutof f valves (D).
3. T urn on the hydraulic power supply .
4. Open the flow control valve (S) all the way .
5. Open the return line shutof f valve first, then open the supply line shutof f valve.

WARNING

COMPONENT RUPTURE HAZARD To reduce the risk of overpressurizing your system, which could cause component rupture and serious injury, never exceed the specified maximum hydraulic input pressure to the pump (see Technical Data on page 46).

6. Open the dispensing valve/spray gun at the last gun station and keep it open while starting the pump.
7. Adjust the pressure reducing valve (P) until you get the desired fluid pressure.
8. When fluid is flowing smoothly from the gun, release the gun trigger .

Shutdown

9. One at a time, open any other guns in the system to purge air from the lines.

WARNING

10. With a gun triggered open (dead-end systems only) or with the pump running in a circulating system, count the cycle rate of the pump for one minute. Close the flow control valve (S) until the cycle rate drops to below the desired cycle rate.

To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 12.

11. Open the flow control valve (S) slowly until the cycle rate and fluid pressure return to the desired level. This method of setting the hydraulic controls ensures proper pump operation and prevents pump runaway and damage if the fluid supply runs dry.

Relieve the pressure.

Always shut off the supply line shutoff valve first, and then the return line shutoff valve. This is to prevent overpressurizing the motor or its seals.

Page 15 of the Graco Air Regulator (220-569) user manual — Packing Nut Tightness
Page 15 · click to enlarge
Page 15

Maintenance

The operating conditions of your particular system determine how often maintenance is required. Estab- lish a good maintenance schedule during the first several weeks of operation by recording when and what kind of maintenance is needed, and then deter- mine a regular schedule for checking your system. Your maintenance schedule should include the follow- ing:

Excessive Leaking at Throat

To monitor leaking at the throat, remove one of the small plugs (31) from the packing nut (21). Place one end of a drain tube in the hole and the other end in a container. See Fig. 4. Monitor the drainage. If it seems excessive, and tightening the packing nut does not help, replace the throat packings. See page 20.

Graco Air Regulator (220-569) — Excessive Leaking at Throat diagram (page 15)
Fig. 5 · Excessive Leaking at Throat

1 Torque to 34–40 Nm (25–30 ft–lb).

Flushing

Graco Air Regulator (220-569) — Flushing diagram (page 15)
Fig. 6 · Flushing

FIRE AND EXPLOSION HAZARD Before flushing, read the section FIRE AND EXPLOSION HAZARD on page 5. Be sure the entire system and flush- ing pails are properly grounded. Refer to Grounding on page 7.

1. Flush before shutting down the system for an extended period of time.
2. Flush before repairing the pump, if possible.
3. Flush before the fluid you are pumping can dry out, settle or set up in the pump and hoses.

Packing Nut Tightness

The packing nut (21) should be tight enough to stop leakage, but no tighter. Overtightening compresses and damages the packings, and may cause the pump to leak, reducing performance. See Fig. 4.

To check the adjustment of the packing nut, first re- lieve fluid pressure. If you have a torque wrench, tighten the packing nut to 34–40 Nm (25–30 ft–lb).

Page 16 of the Graco Air Regulator (220-569) user manual — Mix Tank Volume
Page 16 · click to enlarge
Page 16

Maintenance

Air Line Lubricator

Stop the Pump at the Bottom of Its Stroke

WARNING

Keep properly filled for automatic air motor lubrication.

To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 12.

Air Line Filter

Drain and clean as necessary.

Whenever you stop the pump for any reason, relieve the pressure. Stop the pump on the downstroke, before the air motor changes over. If the pump is stopped on the upstroke a pressure relief seat causes the piston to creep until it reaches the up position. Following the Pressure Relief Procedure helps stop the pump at the bottom of its stroke.

Hydraulic Power Supply Check

Carefully follow the hydraulic power supply manufac- turer’s recommendations on reservoir and filter clean- ing, and periodic changes of hydraulic fluid.

Mix Tank Volume

CAUTION

Don’t let the mix tank run dry. When the tank is empty, the pump demands more power as it tries to suck in some fluid. This causes the pump to run too fast, which can seriously damage the pump.

Failure to stop the pump at the bottom of its stroke allows fluid to dry on the piston rod, which can cause damage to the throat packings when the pump is restarted.

Page 17 of the Graco Air Regulator (220-569) user manual — PROBLEM CAUSE SOLUTION
Page 17 · click to enlarge
Page 17

Troubleshooting

1. Relieve the pressure.

WARNING

2. Check all possible problems and solutions before disassembling pump.

To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 12.

PROBLEM CAUSE SOLUTION

Pump output low on both strokes. Restricted air or hydraulic supply lines.

Clear any obstructions; be sure all shut- off valves are open; increase pressure, but do not exceed maximum working pressure.

Exhausted fluid supply. Refill and reprime pump.

Clogged fluid outlet line, valves, etc. Clear.

Worn piston packing (15). Replace. See page 20.

Pump output low on only one stroke.

Held open or worn check valve. Check and repair.

Worn piston packing (15). Replace. See page 20.

Pump operates erratically. Exhausted fluid supply. Refill and reprime pump.

Held open or worn check valves. Check and repair.

Worn piston packing (15). Replace. See page 20.

Excessive hydraulic fluid supply pres- sure to Viscount motor.

See Viscount motor manual.

Pump will not operate. Restricted air or hydraulic supply lines.

Clear any obstructions; be sure all shut- off valves are open; increase pressure, but do not exceed maximum working pressure.

Exhausted fluid supply. Refill and reprime pump.

Clogged fluid outlet line, valves, etc. Clear.

Damaged air motor or hydraulic mo- tor.

See motor manual.

Fluid dried on piston rod (17). Disassemble and clean pump (see page 20). In future, stop pump at bottom of stroke.

Pump will not prime. Suction line clogged. Clear. Flush more frequently.

Held open or worn check valves. Check and repair.

Piston assembled with wrong nut. Use only the large, round, special nut (12).

Excessive throat leakage. Worn piston rod (17) or throat pack- ings.

Replace. See page 20.

Page 18 of the Graco Air Regulator (220-569) user manual — Reconnecting the Displacement Pump
Page 18 · click to enlarge
Page 18

Service

Disconnecting the Displacement Pump

adapter plate (L) as shown in Fig. 6. Position the displacement pump (D) on the tie rods (C). Lubri- cate the threads of the tie rods. Screw the locknuts (B) onto the tie rods loosely. Screw the coupling nut (K) onto the piston rod (H) and torque to 102–109 Nm (75–80 ft-lb). Torque the tie rod locknuts to 68–75 Nm (50–55 ft-lb).

WARNING

To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 12.

For Viscount hydraulic-powered pumps: Orient the displacement pump (D) to the motor (E) and adapter plate (L) as shown in Fig. 7. Position the displacement pump (D) on the tie rods (C). Lubri- cate the threads of the tie rods. Screw the locknuts (B) onto the tie rods loosely. Screw the coupling nut (K) onto the piston rod (H) and torque to 102–109 Nm (75–80 ft-lb). Torque the tie rod locknuts to 68–75 Nm (50–55 ft-lb).

1. Relieve the pressure.
2. Disconnect the hoses from the displacement pump and plug the ends to prevent fluid contamination.
3. Disconnect the displacement pump from the motor as follows:
2. Flush and test the pump before reinstalling it in the system. Connect hoses for flushing. Flush the pump. While it is pressurized, check for smooth operation and leaks. Adjust or repair as necessary before reinstalling in the system. Reconnect the pump ground wire before operating.

For Senator and Bulldog air-powered pumps: Unscrew the coupling nut (A). Unscrew the lock- nuts (B) from the tie rods (C). Pull the displace- ment pump (D) off the motor (E). Remove the pin (F) and screw the coupling (G) off the piston rod (H). See Fig. 5.

Reassembling a Motor with an Adapter Plate

For President air-powered pumps: Unscrew the coupling nut (K) of the coupling rod (G) from the piston rod (H). Unscrew the locknuts (B) from the tie rods (C). Pull the displacement pump (D) off the motor (E). See Fig. 6.

If your motor has an adapter plate, use this procedure when reassembling the motor and pump, to ensure proper alignment of the motor shaft to the piston rod.

1. Loosen the screws (M) holding the adapter plate (L) to the motor (E). See Fig. 8.

For Viscount hydraulic-powered pumps: Unscrew the coupling nut (K) of the coupling rod (G) from the piston rod (H). Unscrew the locknuts (B) from the tie rods (C). Pull the displacement pump (D) off the motor (E). See Fig. 7.

2. Screw the tie rods (C) into the adapter plate (L) and torque to 68–75 N m (50–55 ft-lb). On V iscount I+ pumps, the tie rods will engage threaded holes in the base of the motor .

Reconnecting the Displacement Pump

3. Fill the cavity in the bottom of the motor shaft with grease. Screw the coupling (G) into the motor shaft until the pin holes align. Install the pin (F) in the second hole from the end of the coupling for President pumps, and in the first hole from the end of the coupling for V iscount pumps.
1. Reconnect the displacement pump to the motor as follows:

For Senator and Bulldog air-powered pumps: Make sure the o-ring (J) is in place in the coupling (G). Screw the coupling onto the piston rod (H) and install the pin (F). Orient the displacement pump (D) to the motor (E) as shown in Fig. 5. Position the displacement pump (D) on the tie rods (C). Lubricate the threads of the tie rods. Screw the locknuts (B) onto the tie rods loosely. Screw the coupling nut (A) onto the motor shaft and torque to 102–109 Nm (75–80 ft-lb). Torque the tie rod locknuts to 68–75 Nm (50–55 ft-lb).

4. Align the tie rods (C) with the displacement pump and loosely install the locknuts (B).
5. Screw the coupling nut (K) onto the piston rod (H) and torque to 102–109 N m (75–80 ft-lb).
6. T orque the screws (M) holding the adapter plate (L) to the motor (E) to 20–23 N m (15–17 ft-lb). T orque the tie rod locknuts (B) to 68–75 N m (50–55 ft-lb).
For President air-powered pumpsOrient the displacement pump (D) to the motor (E) and

Page 19 of the Graco Air Regulator (220-569) user manual — Model 220–564 President Pump Shown
Page 19 · click to enlarge
Page 19

Service

Graco Air Regulator (220-569) — Service diagram (page 19)
Fig. 7 · Service
Graco Air Regulator (220-569) — Service diagram (page 19)
Fig. 8 · Service

Model 220–569

Senator Pump

Shown

E

G

J

F

A

H

Torque to 102–109 Nm (75–80 ft-lb).

B

Lubricate threads.

Torque to 68–75 Nm (50–55 ft-lb).

Torque to 102–109 Nm (75–80 ft-lb).

D

Torque to 68–75 Nm (50–55 ft-lb).

Graco Air Regulator (220-569) — D diagram (page 19)
Fig. 9
Graco Air Regulator (220-569) — D diagram (page 19)
Fig. 10

Model 220–564 President Pump Shown

Torque to 102–109 Nm (75–80 ft-lb).

Lubricate threads.

Torque to 68–75 Nm (50–55 ft-lb).

Torque to 102–109 Nm (75–80 ft-lb).

Torque to 68–75 Nm (50–55 ft-lb).

For President Pumps, install in second hole from end of coupling (G); for Viscount Pumps, use first hole.

Page 20 of the Graco Air Regulator (220-569) user manual — Cleaning and Inspecting Parts
Page 20 · click to enlarge
Page 20

Service

Repair Kits

9. Remove the four capscrews (9) and washers (8) from the intake housing (10). Use a flatblade screwdriver inserted between the lower pump housing (1 1) and the intake housing (10) to sepa - rate the parts.

A pump seal kit is available for each pump size. Throat packing kits are also available, one for UHMWPE/ leather pumps and one for PTFE pumps. The piston seals may also be converted to PTFE. Refer to page 36 for ordering.

10. Remove the balls (5), seats (6 and 32) and gas - kets (7).

Parts supplied in the pump seal kit are marked with one asterisk in the text and drawings, for example (2*). Parts supplied in the throat packing kit are marked with a symbol, for example (19). For the best results, use all the parts in the kit.

WARNING

Disassembling the Displacement Pump

COMPONENT RUPTURE HAZARD The vented ball seat (32) must be in- stalled at the fluid inlet. This valve relieves pressure trapped in the pump cylinder when the pump is shut off, and reduces the risk of pump overpressurization. The seat cannot relieve pressure if installed in any other position.

1. Remove the pump from the motor as explained on page 18.
2. Secure the displacement pump intake housing (10) in a vise.
3. Refer to Fig. 9. Remove the four capscrews (9) and washers (8) from around the pump outlet housing (22).

NOTE: Inspect the parts of the piston assembly (items 12, 15 and 16) in place before disassembling the piston. The piston seal (15) is included in the Seal Repair Kit. If it or any other parts of the piston show wear or damage, proceed to step 11. If no damage is apparent, it is not necessary to disassemble the piston.

4. Remove the outlet housing (22), balls (23), seats (24) and gaskets (7).
5. Remove the three tie bolts (13) and lockwashers (14). Lift of f the upper pump housing (1), along with the fluid tubes (3), cylinder (4), and piston assembly (16).
11. Place the flats of the piston nut (12) in a vise. Unscrew the rod (17) from the nut. Disassemble the two halves of the piston (16) and remove the seal (15).
6. Remove the packing nut (21), glands (19, 26) and packings (20, 25) from the upper housing (1).

Cleaning and Inspecting Parts

Clean all parts in a compatible solvent. Inspect all parts for wear or damage. If you are using a repair kit, use all the new parts in the kit, discarding the old ones they replace. Replace any other parts as needed. Worn or damaged parts may cause the pump to per- form poorly or cause premature wear of the new seals and packings.

7. Remove the tubes (3) and cylinder (4) from the housing.
8. Remove the intake housing (10) from the vise.

Page 21 of the Graco Air Regulator (220-569) user manual — INLET
Page 21 · click to enlarge
Page 21

Service

Model 220–555 Severe–Duty Electropolished Stainless Steel Pump Shown

Lips of v-packings must face down.

Vented seat.

Non-vented seat.

Graco Air Regulator (220-569) — Model 220–555 Severe–Duty Electropolished Stainless Steel Pump Shown diagram (page 21)
Fig. 11 · Model 220–555 Severe–Duty Electropolished Stainless…

31 4 Models 237–220 and 237–221 use 5 PTFE v-packings, instead of 3 UHMWPE (20) and 2 leather (25).

INLET

17 (Ref) ·

Page 22 of the Graco Air Regulator (220-569) user manual — CAUTION
Page 22 · click to enlarge
Page 22

Service

Reassembling the Displacement Pump

7. Lubricate the throat packings and glands. Install them one at a time in the throat of the upper pump housing (1). Make sure the lips of the vpackings face down into the housing, and use a finger to seat the parts: the male gland (19 ), one UHMWPE packing (20 ), one leather packing (25 ), UHMWPE, leather , UHMWPE, and the female gland (26 ). Install the packing nut (21) finger-tight.
1. Place the two halves of the piston (16) around the packing (15*) and snap them together . See Fig. 10.
2. Apply thread sealant to the piston rod (17) threads. Screw the rod through the piston and packings and into the special piston nut (12). T orque the nut to 68–81 N m (50–60 ft-lb).
8. Install the upper pump housing (1). It may not seat well on the tubes and cylinder . Apply thread sea - lant to the threads of the three tie bolts (13). Install the bolts and lockwashers (14) from the lower pump housing (1 1). As you tighten the bolts into the upper housing (1), they will draw the housings firmly onto the tubes and cylinders. T ighten the bolts uniformly and torque to 34–40 N m (25–30 ft-lb).
3. With the lower pump housing (1 1) turned upside down, install the balls (5). Install the seats; place the vented seat (32) in the left side as viewed in Fig. 9 (housing has a label to identify the correct side), and the non-vented seat (6) in the right side. Install the gaskets (7*).
9. T orque the packing nut (21) to 68–74 N m (50–55 ft-lb).
10. Place a ball (23), seat (24) and gasket (7*) in each side of the outlet housing (22). Install the outlet housing on the upper pump housing (1). Note that the flatter side of the housing faces the outside edge of the pump. Install the lockwashers (8) and screws (9), and torque to 34–40 N m (25–30 ft-lb).
4. Place the intake housing (10) on the lower pump housing (1 1). Install the lockwashers (8) and capscrews (9). T orque to 34–40 N m (25–30 ft-lb). See Fig. 10.
5. Place the intake housing (10) in a vise. Place one o-ring (2*) in each side of the lower pump housing (11) where the tubes (3) sit. Place anoth - er o-ring (2*) in the grooves at each end of the tubes. Place a gasket (18*) in both the upper and lower housings (1 and 1 1). Position the tubes and cylinder (4) in the lower housing (1 1).

CAUTION

When installing the outlet adapters in the pump, be sure to hold the flats of both parts with wrenches. Overtightening the pump adapter into the outlet housing adapter may crack the housing.

6. Lubricate the inside of the cylinder (4). Slide the piston assembly into the cylinder .
11. Reconnect the displacement pump to the motor as explained on page 18.

Page 23 of the Graco Air Regulator (220-569) user manual — Service
Page 23 · click to enlarge
Page 23

Service

Graco Air Regulator (220-569) — Service diagram (page 23)
Fig. 12 · Service

Torque to 34–40 Nm (25–30 ft-lb).

Torque to 68–81 Nm (50–60 ft-lb).

Models 237–220 and 237–221 use 5 PTFE v-packings, instead of 3 UHMWPE (20) and 2 leather (25).

Page 24 of the Graco Air Regulator (220-569) user manual — Model 220–559, Series A, 1.5:1 Ratio
Page 24 · click to enlarge
Page 24

Parts (President Pumps)

CARBON STEEL PUMPS

SEVERE-DUTY, ELECTROPOLISHED STAINLESS STEEL PUMPS

Model 220–559, Series A, 1.5:1 Ratio

Model 220–562, Series A, 1.5:1 Ratio

Model 220–563, Series A, 2:1 Ratio

Model 220–560, Series A, 2:1 Ratio

Model 220–564, Series A, 3:1 Ratio

Model 220–561, Series A, 3:1 Ratio

Model 239–819, Series A, 3:1 Ratio

Model 237–222, Series A, 3:1 Ratio

Model 237–223, Series A, 3:1 Ratio

Ref Part No. No. Description Qty

Ref Part No. No. Description Qty

101 205–038 MOTOR, President; see 306–982 1 102 183–089 ROD, tie; 13.625” (346 mm) between shoulders 3 103 101–946 PIN, cotter; 1/8” dia x 1–1/2” 1 104 156–082 PACKING, o-ring; buna-N 1 105 220–883 COUPLING 1 106 100–450 CAPSCREW, hex hd; 5/16–18 unc–2a x 1” long 3 107 220–557 DISPLACEMENT PUMP for Model 220–562; see page 34 1 220–555 DISPLACEMENT PUMP for Model 220–563; see page 34 1 220–553 DISPLACEMENT PUMP for Model 220–564; see page 34 1 239–820 DISPLACEMENT PUMP for Model 239–819; see page 34 1 237–220 DISPLACEMENT PUMP for Model 237–222; see page 34 1 108 108–683 NUT, lock, hex; 9/16–12 unc 3 113 100–214 LOCKWASHER; 0.318” 3 114 186–071 PLATE, adapter 1 115 183–351 LABEL, ID (not shown) 1

101 205–038 MOTOR, President; see 306–982 1 102 183–033 ROD, tie; 13.625” (346 mm) between shoulders 3 103 100–103 PIN, cotter; 1/8” dia x 1–1/2” 1 104 156–082 PACKING, o-ring; buna-N 1 105 220–883 COUPLING 1 106 100–450 CAPSCREW, hex hd; 5/16–18 unc–2a x 1” long 3 107 220–551 DISPLACEMENT PUMP for Model 220–559; see page 32 1 220–549 DISPLACEMENT PUMP for Model 220–560; see page 32 1 220–547 DISPLACEMENT PUMP for Model 220–561; see page 32 1 237–221 DISPLACEMENT PUMP for Model 237–223; see page 32 1 108 108–527 NUT, lock, hex; 9/16–12 unc 3 113 100–214 LOCKWASHER; 0.318” 3 114 186–071 PLATE, adapter 1 115 183–351 LABEL, ID (not shown) 1

Page 25 of the Graco Air Regulator (220-569) user manual — Model 220–559, Series A, 1.5:1 Ratio
Page 25 · click to enlarge
Page 25

Parts (President Pumps)

CARBON STEEL PUMPS

Graco Air Regulator (220-569) — CARBON STEEL PUMPS diagram (page 25)
Fig. 13

Model 220–559, Series A, 1.5:1 Ratio

Model 220–560, Series A, 2:1 Ratio

Model 220–561, Series A, 3:1 Ratio

Model 237–223, Series A, 3:1 Ratio

SEVERE-DUTY, ELECTROPOLISHED STAINLESS STEEL PUMPS

Model 220–562, Series A, 1.5:1 Ratio

Model 220–563, Series A, 2:1 Ratio

Model 220–564, Series A, 3:1 Ratio

Model 239–819, Series A, 3:1 Ratio

Model 237–222, Series A, 3:1 Ratio

Page 26 of the Graco Air Regulator (220-569) user manual — Parts (President Pumps)
Page 26 · click to enlarge
Page 26

Parts (President Pumps)

Model 220–574, Series B 3:1 Ratio Carbon Steel President Pump, with 55 gal. drum cover and agitator

Model 220–575, Series B 3:1 Ratio Stainless Steel President Pump, with 55 gal. drum cover and agitator

Ref Part No. No. Description Qty

Ref Part No. No. Description Qty

201 220–561 PUMP, President See page 24 for parts 1 202 237–309 COVER, drum, 55 gal. (200 liter) See 308–466 for parts 1 203 222–698 AGITATOR See 306–840 for parts 1 204 220–580 RISER TUBE KIT See 307–837 for parts 1 205 223–180 AIR REGULATOR KIT Includes items 205a–205c 1 205a 203–716 REGULATOR, air See 308–167 for parts 1 205b 205–418 HOSE, air; buna-N; 1/2” ID; coupled 1/2 npt (mbe); 6 ft (1.9 m) lg 1 205c 158–491 NIPPLE; 1/2 npt 1 206 223–319 RETURN TUBE KIT Includes items 206a–206d 1 206a 185–393 TUBE, return; sst; 1” npt(m) 1 206b 178–941 NUT, hex; 1–5/8–18 unef–2b 1 206c 185–394 ADAPTER, return; 1–5/8–18 unef–2a(m) x 1” npt(f) x 1” npt(f) 1 206d 108–761 ELBOW, street; 1” npt (m x f) 1 207 185–466 NIPPLE, half; 1–1/2” npt 1 208 100–839 ELBOW; 1/8 npt (m x f) 1

201 220–564 PUMP, President See page 24 for parts 1 202 237–309 COVER, drum, 55 gal. (200 liter) See 308–466 for parts 1 203 222–698 AGITATOR See 306–840 for parts 1 204 220–580 RISER TUBE KIT See 307–837 for parts 1 205 223–180 AIR REGULATOR KIT Includes items 205a–205c 1 205a 203–716 REGULATOR, air See 308–167 for parts 1 205b 205–418 HOSE, air; buna-N; 1/2” ID; coupled 1/2 npt (mbe); 6 ft (1.9 m) lg 1 205c 158–491 NIPPLE; 1/2 npt 1 206 223–319 RETURN TUBE KIT Includes items 206a–206d 1 206a 185–393 TUBE, return; sst; 1” npt(m) 1 206b 178–941 NUT, hex; 1–5/8–18 unef–2b 1 206c 185–394 ADAPTER, return; 1–5/8–18 unef–2a(m) x 1” npt(f) x 1” npt(f) 1 206d 108–761 ELBOW, street; 1” npt (m x f) 1 207 185–466 NIPPLE, half; 1–1/2” npt 1 208 100–839 ELBOW; 1/8 npt (m x f) 1 Assembly Procedure

1. Screw the half nipple (207) into the pump’ s fluid inlet. Refer to the parts drawing on page 27.
6. Remove the 1/2 x 3/8 npt nipple from the outlet of the air regulator (205a). This nipple will not be used.
2. Remove the four nuts and lockwashers from the posts of the drum cover (202) and save them for use in step 3.
7. Screw the 1/2 npt nipple (205c) into the outlet of the air regulator (205a), then install the regulator assembly into the pump’ s air inlet. Connect the air hose (205b) to the swivel inlet (B) of the air regula - tor.
3. Install the President pump (201) through the hole in the drum cover (202). The four posts on the drum cover must engage the four holes in the pump adapter plate (1 14), and the notch in the drum cover hole must align with the large hole in the pump adapter plate. Secure the pump to the drum cover with the lockwashers and nuts re - moved in step 2.
8. Insert the male end of the return adapter (206c) in the outermost hole of the drum cover . Secure the adapter to the underside of the cover with the hex nut (206b).
4. Install the agitator (203) on the drum cover (202), using the screws, washers and nuts supplied with the drum cover .
9. Screw the return tube (206a) up into the adapter (206c). Install the street elbow (206d) in the adapt - er.
5. Assemble the riser tube kit (204) to the pump adapter plate (1 14) and pump fluid outlet (A) as described in the separate kit manual, 307–837.
10. Install the pump/cover/agitator assembly on a 55 gal. (200 liter) drum. Connect the air , fluid, and return lines.

Page 27 of the Graco Air Regulator (220-569) user manual — B
Page 27 · click to enlarge
Page 27

Parts (President Pumps)

Model 220–574, Series B 3:1 Ratio Carbon Steel President Pump, with 55 gal. drum cover and agitator Includes items 201–208

Remove and discard 1/2 x 3/8 npt nipple from outlet of air regulator (205a), and replace with 1/2 npt nipple (205c). Then connect air regulator assy to pump air inlet.

Connect air hose (205b–not shown) to air regulator inlet fitting (B).

Model 220–575, Series B 3:1 Ratio Stainless Steel President Pump, with 55 gal. drum cover and agitator Includes items 201–208

3 Agitator (203) is tilted at a 6 angle.

Graco Air Regulator (220-569) — Parts (President Pumps) diagram (page 27)
Fig. 14 · Parts (President Pumps)

Ref No. 205 includes items 205a–205c.

Ref No. 206 includes items 206a–206d.

B

Show 5 more labels / short text on this page
205a · 206d · 206b · 206a ·
Page 28 of the Graco Air Regulator (220-569) user manual — Model 220–568, Series A, 3.5:1 Ratio
Page 28 · click to enlarge
Page 28

Parts (Quiet Senator Pumps)

CARBON STEEL PUMPS Model 220–565, Series A, 3.5:1 Ratio

Model 220–566, Series A, 5:1 Ratio

Model 220–567, Series A, 2.5:1 Ratio

Ref Part No. No. Description Qty

Graco Air Regulator (220-569) — Model 220–566, Series A, 5:1 Ratio diagram (page 28)
Fig. 15 · Model 220–566, Series A, 5:1 Ratio

101 220–571 MOTOR, Quiet Senator See 307–592 for parts 1 102 183–033 ROD, tie; 13.625” (346 mm) between shoulders 3 103 100–103 PIN, cotter; 1/8” dia x 1–1/2” 1 104 108–284 PACKING, o-ring; buna-N 1 105 183–041 COUPLING 1 106 183–042 NUT, coupling 1 107 220–549 DISPLACEMENT PUMP Used on Model 220–565 See separate parts list on page 32 1 220–547 DISPLACEMENT PUMP Used on Model 220–566 See separate parts list on page 32 1 220–551 DISPLACEMENT PUMP Used on Model 220–567 See separate parts list on page 32 1 108 108–527 NUT, lock, hex; 9/16–12 unc 3 113 181–096 LABEL, ID (not shown) 1

SEVERE-DUTY, ELECTROPOLISHED STAINLESS STEEL PUMPS

Model 220–568, Series A, 3.5:1 Ratio

Model 220–569, Series A, 5:1 Ratio

Model 220–570, Series A, 2.5:1 Ratio

Ref Part No. No. Description Qty

101 220–571 MOTOR, Quiet Senator See 307–592 for parts 1 102 183–089 ROD, tie; 13.625” (346 mm) between shoulders 3 103 101–946 PIN, cotter; 1/8” dia x 1–1/2” 1 104 108–284 PACKING, o-ring; buna-N 1 105 183–084 COUPLING 1 106 183–079 NUT, coupling 1 107 220–555 DISPLACEMENT PUMP Used on Model 220–568 See separate parts list on page 34 1 220–553 DISPLACEMENT PUMP Used on Model 220–569 See separate parts list on page 34 1 220–557 DISPLACEMENT PUMP Used on Model 220–570 See separate parts list on page 34 1 108 108–683 NUT, lock, hex; 9/16–12 unc 3 113 181–096 LABEL, ID (not shown) 1

·

Page 29 of the Graco Air Regulator (220-569) user manual — Model 220–578, Series A , 4:1 Ratio
Page 29 · click to enlarge
Page 29

Parts (Quiet Bulldog Pumps)

CARBON STEEL PUMPS

Graco Air Regulator (220-569) — CARBON STEEL PUMPS diagram (page 29)
Fig. 16

Model 220–577, Series A, 4:1 Ratio

Ref Part No. No. Description Qty

101 215–255 MOTOR, Quiet Bulldog See 307–304 for parts 1 102 183–033 ROD, tie; 13.625” (346 mm) between shoulders 3 103 100–103 PIN, cotter; 1/8” dia x 1–1/2” 1 104 108–284 PACKING, o-ring; buna-N 1 105 183–041 COUPLING 1 106 183–042 NUT, coupling 1 107 220–551 DISPLACEMENT PUMP See separate parts list on page 32 1 108 108–527 NUT, lock, hex; 9/16–12 unc 3 113 181–096 LABEL, ID (not shown) 1

SEVERE-DUTY, ELECTROPOLISHED STAINLESS STEEL PUMPS

Model 220–578, Series A , 4:1 Ratio

Model 239–815, Series A , 4:1 Ratio

Ref Part No. No. Description Qty

101 215–255 MOTOR, Quiet Bulldog See 307–304 for parts 1 102 183–089 ROD, tie; 13.625” (346 mm) between shoulders 3 103 101–946 PIN, cotter; 1/8” dia x 1–1/2” 1 104 108–284 PACKING, o-ring; buna-N 1 105 183–084 COUPLING 1 106 183–079 NUT, coupling 1 107 220–557 DISPLACEMENT PUMP for Model 220–578; See separate parts list on page 34 1 239–816 DISPLACEMENT PUMP for Model 239–815; See separate parts list on page 34 1 108 108–683 NUT, lock, hex; 9/16–12 unc 3 113 181–096 LABEL, ID (not shown) 1

Page 30 of the Graco Air Regulator (220-569) user manual — Notes
Page 30 · click to enlarge
Page 30

Notes

Page 31 of the Graco Air Regulator (220-569) user manual — Model 236–602, Series A
Page 31 · click to enlarge
Page 31

Parts (V iscount I+ Pumps)

CARBON STEEL PUMPS Model 236–601, Series A

Model 236–605, Series A

Model 236–712, Series A

Graco Air Regulator (220-569) — Model 236–605, Series A diagram (page 31)
Fig. 17 · Model 236–605, Series A

Ref Part No. No. Description Qty

101 236–417 MOTOR, hydraulic, Viscount I+ See 308–330 for parts 1 102 183–033 ROD, tie; 13.625” (346 mm) between shoulders 3 103 100–103 PIN, cotter; 1/8” dia x 1–1/2” 1 104 156–082 PACKING, o-ring; buna-N 1 105 220–883 COUPLING 1 107 220–549 DISPLACEMENT PUMP Used on Model 236–605 See separate parts list on page 32 1 220–547 DISPLACEMENT PUMP Used on Model 236–601 See separate parts list on page 32 1 220–551 DISPLACEMENT PUMP Used on Model 236–712 See separate parts list on page 32 1 108 108–527 NUT, lock, hex; 9/16–12 unc 3 112 100–001 SCREW, cap, hex hd; 5/16–18 unc–2a x 0.625 in. (16 mm) 4 113 100–214 LOCKWASHER; 0.318” 4 114 189–206 PLATE, adapter 1

SEVERE-DUTY, ELECTROPOLISHED STAINLESS STEEL PUMPS

Model 236–602, Series A

Model 236–606, Series A

Model 236–713, Series A

Ref Part No. No. Description Qty

101 236–417 MOTOR, hydraulic, Viscount I+ See 308–330 for parts 1 102 183–089 ROD, tie; 13.625” (346 mm) between shoulders 3 103 101–946 PIN, cotter; 1/8” dia x 1–1/2” 1 104 156–082 PACKING, o-ring; buna-N 1 105 220–883 COUPLING 1 107 220–555 DISPLACEMENT PUMP Used on Model 236–606 See separate parts list on page 34 1 220–553 DISPLACEMENT PUMP Used on Model 236–602 See separate parts list on page 34 1 220–557 DISPLACEMENT PUMP Used on Model 236–713 See separate parts list on page 34 1 108 108–683 NUT, lock, hex; 9/16–12 unc 3 112 100–001 SCREW, cap, hex hd; 5/16–18 unc–2a x 0.625 in. (16 mm) 4 113 100–214 LOCKWASHER; 0.318” 4 114 189–206 PLATE, adapter 1 03248

Page 32 of the Graco Air Regulator (220-569) user manual — 237–221 181–899 187–761 PTFE
Page 32 · click to enlarge
Page 32

Parts

CARBON STEEL DISPLACEMENT PUMPS Model 220–549, Series D For Pump Models 220–560, 220–565, and 236–605

Model 220–551, Series D For Pump Models 220–559, 220–567, 220–577, and 236–712

Model 220–547, Series D For Pump Models 220–561, 220–566, and 236–601

Model 237–221, Series A For Pump Model 237–223

Ref Part No. No. Description Qty

Ref Part No. No. Description Qty

1 181–727 HOUSING, pump, upper 1 2* 108–526 PACKING, o-ring; PTFE 6 3 183–085 TUBE, fluid 2 4 See Matrix CYLINDER, pump 1 5 101–968 BALL; sst; 1.25” dia. 2 6 181–686 SEAT, valve, non-vented 1 7* 181–877 GASKET, seat, valve; UHMWPE 4 8 111–003 WASHER, flat; 8.4 mm; sst 8 9 107–558 CAPSCREW, hex hd; M8 x 1.25 x 25 8 10 181–729 HOUSING, intake 1 11 181–730 HOUSING, pump, lower 1 12 108–528 NUT, piston 1 13 108–524 CAPSCREW, hex hd; 9/16–12 unc x 7.75” long 3 14 101–333 LOCKWASHER, spring; 9/16” 3 15* See Matrix PACKING, piston 1 16 See Matrix PISTON 2 17 181–898 ROD, piston 1 18* See Matrix GASKET, cylinder; UHMWPE 2 19 183–293 GLAND, male; sst 1 20 See Matrix V-PACKING, throat See Matrix 21 181–684 NUT, packing 1

22 181–728 HOUSING, outlet 1 23 110–259 BALL; sst; 1” dia. 2 24 183–095 SEAT, valve; sst 2 25 See Matrix V-PACKING, throat See Matrix 26 187–117 GLAND, female; sst 1 31 110–208 PLUG, pipe, headless; 1/8 npt; sst 2 32 220–996 SEAT, valve, vented 1 33 183–478 PLATE, warning 1 34 100–508 SCREW, drive, type U; 3/16” long 2

* These parts are included in the Seal Repair Kit, which

may be purchased separately. Refer to the Parts Matrix to determine the correct kit for your pump. See also page 36.

These parts are included in the Throat Packing Repair Kit, which may be purchased separately. Refer to the Parts Matrix to determine the correct kit for your pump. See also page 36.

Replacement Danger and Warning labels, tags and cards

are available at no cost.

Parts Matrix

Find the part number of your pump in the left column. Read across from left to right to find the applicable part num- bers for ref. numbers 4, 15, 16, 18, 20, 25, the Seal Repair Kit, and the Throat Repair Kit.

Ref. No. 15* Piston Packing

Ref. No. 18* Cylin- der Gasket

Ref. No. 20 V-Packing

Ref. No. 25 V-Packing

Ref. No. 4 Cylinder

Ref No. 16 Piston

220–549 183–032 183–039 uhmwpe

183–040 183–094 183–295 uhmwpe (3)

220–551 181–900 181–793 uhmwpe

181–792 181–876 183–295 uhmwpe (3)

220–547 181–899 181–680 uhmwpe

181–685 181–875 183–295 uhmwpe (3)

237–221 181–899 187–761 PTFE

181–685 181–875 None 183–352 PTFE (5)

* These parts are included in the Seal Repair Kit, which may be purchased separately. Refer to page 36.

These parts are included in the Throat Packing Repair Kit, which may be purchased separately. Refer to page 36.

Show 11 more labels / short text on this page
Pump Model · Seal Repair Kit · Throat Repair Kit · 183–294 Leather (2) · 220–588 220–586 · 183–294 Leather (2) · 220–587 220–586 · 183–294 Leather (2) · 220–589 220–586 · 224–934 220–585 ·
Page 33 of the Graco Air Regulator (220-569) user manual — Parts
Page 33 · click to enlarge
Page 33

Parts

CARBON STEEL DISPLACEMENT PUMPS Model 220–549, Series D For Pump Models 220–560, 220–565, and 236–605

Model 220–551, Series D For Pump Models 220–559, 220–567, 220–577, and 236–712

Model 220–547, Series D For Pump Models 220–561, 220–566, and 236–601

Model 237–221, Series A For Pump Model 237–223

4 Model 237–221 uses 5 PTFE v-packings, instead of 3 UHMWPE (20) and 2 leather (25).

Graco Air Regulator (220-569) — Parts diagram (page 33)
Fig. 18 · Parts
Show 4 more labels / short text on this page
17 (Ref) · 15* · *7 ·
Page 34 of the Graco Air Regulator (220-569) user manual — 237–220 183–049 187–761 PTFE
Page 34 · click to enlarge
Page 34

Parts

SEVERE-DUTY ELECTROPOLISHED STAINLESS STEEL DISPLACEMENT PUMPS

Model 220–555, Series E; for Pump Models 220–563, 220–568, and 236–606

Model 220–557, Series E; for Pump Models 220–562, 220–570, 220–578, and 236–713

Model 239–816, Series A; for Pump Model 239–815

Model 220–553, Series E; for Pump Models 220–564, 220–569, and 236–602

Model 239–820, Series A; for Pump Model 239–819

Model 237–220, Series A; for Pump Model 237–222

Ref Part No. No. Description Qty

Ref Part No. No. Description Qty

1 181–906 HOUSING, pump, upper 1 2* 108–526 PACKING, o-ring; PTFE 6 3 183–085 TUBE, fluid 2 4 See Matrix CYLINDER, pump 1 5 101–968 BALL; sst; 1.25” dia. 2 6 181–686 SEAT, valve, non-vented 1 7* 181–877 GASKET, seat, valve; UHMWPE 4 8 111–003 WASHER, flat; 8.4 mm; sst 8 9 112–084 CAPSCREW, hex hd; M8 x 1.25 x 25 8 10 188–103 HOUSING, intake 1 239–817 HOUSING, intake; used on Models 239–816 and 239–820 only 1 11 181–905 HOUSING, pump, lower 1 12 108–528 NUT, piston 1 13 108–523 CAPSCREW, hex hd; 9/16–12 unc x 7.75” long 3 14 108–525 LOCKWASHER, spring; 9/16” 3 15* See Matrix PACKING, piston 1 16 See Matrix PISTON 2 17 181–898 ROD, piston 1 18* See Matrix GASKET, cylinder; UHMWPE 2 19 183–293 GLAND, male; sst 1 20 See Matrix V-PACKING, throat See Matrix 21 181–684 NUT, packing 1

22 188–104 HOUSING, outlet 1 239–818 HOUSING, outlet; used on Models 239–816 and 239–820 only 1 23 110–259 BALL; sst; 1” dia. 2 24 183–095 SEAT, valve; sst 2 25 See Matrix V-PACKING, throat See Matrix 26 187–117 GLAND, female; sst 1 31 110–208 PLUG, pipe, headless; 1/8 npt; sst 2 32 220–996 SEAT, valve, vented 1 33 183–478 PLATE, warning 1 34 103–972 SCREW, drive, type U; 3/16” long 2

* These parts are included in the Seal Repair Kit, which

may be purchased separately. Refer to the Parts Matrix to determine the correct kit for your pump. See also page 36.

These parts are included in the Throat Packing Repair Kit, which may be purchased separately. Refer to the Parts Matrix to determine the correct kit for your pump. See also page 36.

Replacement Danger and Warning labels, tags and cards

are available at no cost.

Parts Matrix

Find the part number of your pump in the left column. Read across from left to right to find the applicable part num- bers for ref. numbers 4, 15, 16, 18, 20, 25, the Seal Repair Kit, and the Throat Repair Kit.

Ref. No. 15* Piston Packing

Ref. No. 18* Cylin- der Gasket

Ref. No. 20 V-Packing

Ref. No. 25 V-Packing

Ref. No. 4 Cylinder

Ref No. 16 Piston

Throat Repair Kit

220–555 183–047 183–039 uhmwpe

183–082 183–094 183–295 uhmwpe (3)

220–557 & 239–816 183–048 181–793 uhmwpe

183–083 181–876 183–295 uhmwpe (3)

220–553 & 239–820 183–049 181–680 uhmwpe

183–081 181–875 183–295 uhmwpe (3)

237–220 183–049 187–761 PTFE

183–081 181–875 None 183–352 PTFE (5)

* These parts are included in the Seal Repair Kit, which may be purchased separately. Refer to page 36.

These parts are included in the Throat Packing Repair Kit, which may be purchased separately. Refer to page 36.

Show 10 more labels / short text on this page
Pump Model · Seal Repair Kit* · 183–294 Leather (2) · 220–588 220–586 · 183–294 Leather (2) · 220–587 220–586 · 183–294 Leather (2) · 220–589 220–586 · 224–934 220–585 ·
Page 35 of the Graco Air Regulator (220-569) user manual — SEVERE-DUTY ELECTROPOLISHED STAINLESS STEEL DISPLACEMENT PUMPS
Page 35 · click to enlarge
Page 35

Parts

SEVERE-DUTY ELECTROPOLISHED STAINLESS STEEL DISPLACEMENT PUMPS

Model 220–555, Series E; for Pump Models 220–563, 220–568, and 236–606

Model 220–557, Series E; for Pump Models 220–562, 220–570, 220–578, and 236–713

Model 239–816, Series A; for Pump Model 239–815

Model 220–553, Series E; for Pump Models 220–564, 220–569, and 236–602

Model 239–820, Series A; for Pump Model 239–819

Model 237–220, Series A; for Pump Model 237–222

Graco Air Regulator (220-569) — SEVERE-DUTY ELECTROPOLISHED STAINLESS STEEL DISPLACEMENT PUMPS diagram (page 35)
Fig. 19

4 Model 237–220 uses 5 PTFE v-packings, instead of 3 UHMWPE (20) and 2 leather (25).

This style manifold used on Models 239–816 and 239–820 only.

Show 4 more labels / short text on this page
17 (Ref) · 15* · 7* ·
Page 36 of the Graco Air Regulator (220-569) user manual — Repair Kits
Page 36 · click to enlarge
Page 36

Repair Kits

Pump Seal Kit 220–589 For Pump Models 220–566, 220–569, 220–561, 220–564, 239–819, 236–601, and 236–602.

Pump PTFESeal Conversion Kit 224–936 For Pump Models 220–577, 220–578, 239–815, 220–567, 220–570, 220–559, 220–562, 236–712 and 236–713.

Ref Part No. No. Description Qty

2 108–526 Packing 6 7 181–877 Gasket 4 15 181–680 Packing; UHMWPE 1 18 181–875 Gasket 2

Ref Part No. No. Description Qty

2 108–526 Packing 6 7 181–877 Gasket 4 15 187–763 Packing; PTFE 1 18 181–876 Gasket 2

Pump Seal Kit 220–588 For Pump Models 220–565, 220–568, 220–560, 220–563, 236–605, and 236–606.

Ref Part No. No. Description Qty

High Temperature Seal Conversion Kit 236–057 For Pump Models 220–566, 220–569, 220–561, 220–564, 239–819, 236–601, and 236–602.

2 108–526 Packing 6 7 181–877 Gasket 4 15 183–039 Packing; UHMWPE 1 18 183–094 Gasket 2

Pump Seal Kit 220–587 For Pump Models 220–577, 220–578, 239–815, 220–567, 220–570, 220–559, 220–562, 236–712 and 236–713.

Ref Part No. No. Description Qty

2 108–526 Packing 6 7 181–877 Gasket 4 15 188–851 Packing; UHMWPE 1 18 181–875 Gasket 2

Ref Part No. No. Description Qty

2 108–526 Packing 6 7 181–877 Gasket 4 15 181–793 Packing; UHMWPE 1 18 181–876 Gasket 2

Throat Packing Kit 220–586 For all pumps.

Pump PTFESeal Kit 224–934 To repair Pump Models 237–222 and 237–223, or con- vert Models 220–566, 220–569, 220–561, 220–564, 239–819, 236–601, and 236–602 to PTFE piston packing.

Ref Part No. No. Description Qty

19 183–293 Gland 1 20 183–295 Packing 3 25 183–294 Packing 2 26 187–117 Gland 1

Ref Part No. No. Description Qty

2 108–526 Packing 6 7 181–877 Gasket 4 15 187–761 Packing; PTFE 1 18 181–875 Gasket 2

Throat Packing PTFE Kit 220–585 With PTFE packings. For all pumps. Throat packing repair kit for Models 237–222 and 237–223.

Pump PTFESeal Conversion Kit 224–935 For Pump Models 220–565, 220–568, 220–560, 220–563, 236–605, and 236–606.

Ref Part No. No. Description Qty

Ref Part No. No. Description Qty

2 108–526 Packing 6 7 181–877 Gasket 4 15 187–762 Packing; PTFE 1 18 183–094 Gasket 2

19 183–293 Gland 1 25 183–352 Packing 5 26 187–117 Gland 1

Page 37 of the Graco Air Regulator (220-569) user manual — Surge Stand
Page 37 · click to enlarge
Page 37

Dimensions

Graco Air Regulator (220-569) — Dimensions diagram (page 37)
Fig. 20 · Dimensions
Graco Air Regulator (220-569) — Dimensions diagram (page 37)
Fig. 21 · Dimensions

1–1/2 in. npt(f)

Surge Stand

Bolt Pattern

Mounting Hole

Diagram

Graco Air Regulator (220-569) — Surge Stand diagram (page 37)
Fig. 22 · Surge Stand
Graco Air Regulator (220-569) — Surge Stand diagram (page 37)
Fig. 23 · Surge Stand

247.7 mm (9.75 in.)

185.0 mm (7.4 in.) Radius

Four 11.1 mm (0.437 in.) diameter holes on 10.5 in. Bolt Circle

Three 17 mm (0.68 in.) Holes

Gasket 161–806 ·

Page 38 of the Graco Air Regulator (220-569) user manual — Fluid Supply Hose
Page 38 · click to enlarge
Page 38

Accessories

Use Only Genuine Graco Parts and Accessories

Grounding W ire and Clamp 237–569

Pump Runaway V alve 224–040

0.8 MPa, 8.4 bar (120 psi) Maximum Working Pressure

7.6 m (25 ft) long

Shuts off air supply to the pump if the pump accelerates beyond the pre-adjusted setting due to an empty supply container, interrupted fluid supply to the pump, or excessive cavitation. 3/4 npt(f) inlet and outlet. Includes optional 90 3/4 npsm swivel outlet fitting. See instruction manual 308–201.

Bleed-T ype Master Air V alve

2.1 MPa, 21 bar (300 psi) Maximum Working Pressure

Relieves air trapped in the air line between the pump air inlet and this valve when closed.

Air Line Lubricator

1.75 MPa, 17.5 bar (250 psi) Maximum Working Pressure

107–141 3/4 npt (mxf) inlet and outlet 107–142 1/2 npt (mxf) inlet and outlet

For automatic air motor lubrication.

214–848 1/2 npt(f) inlet and outlet 214–849 3/4 npt(f) inlet and outlet

Air Control Kit 207–651

2.1 MPa, 21 bar (300 psi) Maximum Working Pressure 0.1–0.9 MPa, 1–9 bar (10–125 psi) Adjustable Outlet Pressure Range

Medium V olume High-Flo Surge T ank 220–157

Reduces fluid pulsation in the fluid line. Stainless steel. 1 in. npt(f) inlet; 1–1/2 npt(f) outlet. Refer to manual 307–707.

Graco Air Regulator (220-569) — Medium V olume High-Flo Surge T ank 220–157 diagram (page 38)
Fig. 24 · Medium V olume High-Flo Surge T ank 220–157

Includes air regulator, gauge, bleed-type master air valve, hose, and manifold. Inlet: 3/4 npsm(f) swivel; Outlet: 3/4 npt(m). See manual 308–168.

Riser T ube Kits

Adapts medium volume High-Flo displacement pump outlet to motor level when the pump is drum mounted.

220–580 For President and Viscount Pumps

220–584 For Senator and Bulldog Pumps

Air Line Filter

Refer to medium volume High-Flo Accessories Manual 307–837.

1.75 MPa, 17.5 bar (250 psi) Maximum Working Pressure

Fluid Supply Hose

Removes harmful moisture and contaminants from the compressed air supply.

3.5 MPa, 35 bar (500 psi) Maximum Working Pressure

1 in. ID, coupled 1–11 1/2 npt(mbe).

106–149 1/2 npt(f) inlet and outlet 106–150 3/4 npt(f) inlet and outlet

220–997 0.6 m (2 ft) long

214–959 1.8 m (6 ft) long

Page 39 of the Graco Air Regulator (220-569) user manual — Throat Seal Liquid (TSL)
Page 39 · click to enlarge
Page 39

Accessories

Use Only Genuine Graco Parts and Accessories

Graco-Approved Hydraulic Fluid

Mounting Stand Kit 218–742

169–236 20 liter (5 gal.)

For mounting the surge tank to the floor.

207–428 3.8 liter (1 gal.)

Hydraulic Shutoff V alve 102–644

For hydraulic supply or return line. 3/4 npt(f).

Hydraulic Supply and Return Hose

10.5 MPa, 105 bar (1500 psi) Maximum Working Pressure

Pump Floor Stand 220–581

For mounting medium volume High-Flo pumps in a suction feed system. Refer to the Medium Volume High-Flo Accessories Manual, 307–837.

5/8 in. ID, coupled 3/4 npt x 7/8–14, 90 swivel elbow, grounded, for return line.

180–091 0.9 m (3 ft) long

180–092 1.8 m (6 ft) long

13.8 MPa, 138 bar (2000 psi) Maximum Working Pressure

1/2 in. ID, coupled 1/2 npt(m) x 3/4–16, 90 swivel elbow, grounded, for supply line.

180–090 0.9 m (3 ft) long

Stationary Stand 207–872

For President, Bulldog, and Senator Pumps.

180–093 1.8 m (6 ft) long

Pump Mounting Adapter Kits

W all Bracket 206–221

Provides adapter plate and tie rods for retrofitting existing motor to a High-Flo displacement pump. Refer to Medium Volume High-Flo Accessories Manual 307–837.

For mounting medium volume High-Flo pump to a wall.

Portable Cart 218–028

220–579 For Series A, B, C, or D Bulldog Mo- tors, Part No. 208–356, and Series A Senator Motor, Part No. 217–540. More recent series of these motors do not require this kit.

For President, Bulldog, and Senator Pumps.

Packing Nut Wrench 1 10–335

For tightening the packing nut.

221–159 Required for all Viscount I and Presi- dent Motors.

Siphon T ube Kit 213–099

To draw fluid from a 200 liter (55 gallon) drum.

Throat Seal Liquid (TSL)

Non-evaporating liquid for packing nut/wet-cup.

206–995 0.95 liter (1 quart)

206–996 3.8 liter (1 gal.)

Page 40 of the Graco Air Regulator (220-569) user manual — AIR CONSUMPTION
Page 40 · click to enlarge
Page 40

Technical Data

1.5:1 Ratio President Pumps, Models 220–559 and 220–562

Maximum Working Pressure 1.9 MPa, 19 bar (270 psi) Air Operating Range 0.1–1.2 MPa, 1.4–12 bar (20–180 psi) . Air Consumption See Performance Chart Continuous Duty Delivery 75 liter/min (20 gpm) Pump Cycles Per Liter (gallon) 0.80 (3.0) Maximum Recommended Pump Speed 60 cycles/min Air Inlet 1/2 npt(f)

Fluid Inlet 1–1/2” npt(f) Fluid Outlet 1” npt Wetted Parts

Model 220–559 Carbon Steel, Stainless Steel, Ultra-High Molecular Weight Polyethylene, Leather, PTFE Model 220–562 Chrome-Plated Stainless Steel, Ultra-High Molecular Weight Polyethylene, Leather, PTFE

CPM

CFM m3/min PSI

10 18 27 36 45 54

2.8, 28

Graco Air Regulator (220-569) — CPM diagram (page 40)
Fig. 25

A 0.7 MPa, 7 bar (100 psi) air pressure B 0.49 MPa, 4.9 bar (70 psi) air pressure C 0.28 MPa, 2.8 bar (40 psi) air pressure

PUMP OUTLET PRESSURE

2.1, 21

To find Outlet Pressure (MPa/bar/psi) at a specific delivery (liter/min or gpm) and operating air pressure (MPa/bar/psi): 1. Locate desired delivery along bottom of chart. 2. Read vertical line up to intersection with selected fluid outlet pressure curve (black curves). Curve slopes from left to right. Follow left to scale and read outlet pressure.

60 1.68

AIR CONSUMPTION

1.7, 17

50 1.40

1.4, 14

40 1.12

1.05, 10.5

To find Pump Air Consumption (m3/min or CFM/min) at a specific delivery (liter/min or gpm) and operating air pressure (MPa/bar/psi): 1. Locate desired delivery along bottom of chart. 2. Read vertical line up to intersection with selected air consumption curve (gray curves). Curve slopes from right to left. Follow right to scale and read air consumption.

0.7, 7

0.35, 3.5

11 23 34 46 57 68 79 GPM l/min

0 3 6 9 12 15 18 21

PUMP DELIVERY (T est FluidNo. 10 Motor Oil)

2:1 Ratio President Pumps, Models 220–560 and 220–563

Maximum Working Pressure 2.5 MPa, 25 bar (360 psi) Air Operating Range 0.1–1.2 MPa, 1.4–12 bar (20–180 psi) . Air Consumption See Performance Chart Continuous Duty Delivery 55 liter/min (14.6 gpm) Pump Cycles Per Liter (gallon) 1.0 (4.1) Maximum Recommended Pump Speed 60 cycles/min Air Inlet 1/2 npt(f)

Fluid Inlet 1–1/2” npt(f) Fluid Outlet 1” npt Wetted Parts

Model 220–560 Carbon Steel, Stainless Steel, Ultra-High Molecular Weight Polyethylene, Leather, PTFE Model 220–563 Chrome-Plated Stainless Steel, Ultra-High Molecular Weight Polyethylene, Leather, PTFE

8 16 25 33 41 49 CPM

PSI

CFM m3/min

A 0.7 MPa, 7 bar (100 psi) air pressure B 0.49 MPa, 4.9 bar (70 psi) air pressure C 0.28 MPa, 2.8 bar (40 psi) air pressure

2.8, 28

Graco Air Regulator (220-569) — 8 16 25 33 41 49 CPM diagram (page 40)
Fig. 26

2.45, 24.5

To find Outlet Pressure (MPa/bar/psi) at a specific delivery (liter/min or gpm) and operating air pressure (MPa/bar/psi): 1. Locate desired delivery along bottom of chart. 2. Read vertical line up to intersection with selected fluid outlet pressure curve (black curves). Curve slopes from left to right. Follow left to scale and read outlet pressure.

PUMP OUTLET PRESSURE

2.1, 21

60 1.68

AIR CONSUMPTION

1.7, 17

50 1.40

1.4, 14

40 1.12

1.05, 10.5

To find Pump Air Consumption (m3/min or CFM/min) at a specific delivery (liter/min or gpm) and operating air pressure (MPa/bar/psi): 1. Locate desired delivery along bottom of chart. 2. Read vertical line up to intersection with selected air consumption curve (gray curves). Curve slopes from right to left. Follow right to scale and read air consumption.

0.7, 7

0.35, 3.5

0 2 4 6 8 10 12 14 16

8 15 23 30 38 46 54 GPM l/min 62

PUMP DELIVERY (T est FluidNo. 10 Motor Oil)

MPa, BAR · MPa, BAR ·

Page 41 of the Graco Air Regulator (220-569) user manual — B
Page 41 · click to enlarge
Page 41

Technical Data

3:1 Ratio President Pumps, Models 220–561, 220–564, 237–222, 237–223, and 239–819

Maximum Working Pressure 3.4 MPa, 34 bar (500 psi) Air Operating Range 0.1–1.1 MPa, 1.4–11 bar (20–166 psi) . Air Consumption See Performance Chart Continuous Duty Delivery 35.3 liter/min (9.3 gpm) Pump Cycles Per Liter (gallon) 1.7 (6.25) Maximum Recommended Pump Speed 60 cycles/min Air Inlet 1/2 npt(f) Fluid Inlet 1–1/2” npt(f) Fluid Outlet 1” npt

Model 220–561 Carbon Steel, Stainless Steel, Ultra-High Molecular Weight Polyethylene, Leather, PTFE Model 220–564 Chrome-Plated Stainless Steel, Ultra-High Molecular Weight Polyethylene, Leather, PTFE Model 237–223 Carbon Steel, Stainless Steel, Ultra-High Molecular Weight Polyethylene, PTFE Model 237–222 Chrome-Plated Stainless Steel, Ultra-High Molecular Weight Polyethylene, PTFE

12 25 37 50 62 74 CPM

PSI

2.8, 28

CFM m3/min

A 0.7 MPa, 7 bar (100 psi) air pressure B 0.49 MPa, 4.9 bar (70 psi) air pressure C 0.28 MPa, 2.8 bar (40 psi) air pressure

2.45, 24.5

PUMP OUTLET PRESSURE

2.1, 21

60 1.68 A

To find Outlet Pressure (MPa/bar/psi) at a specific delivery (liter/min or gpm) and operating air pressure (MPa/bar/psi): 1. Locate desired delivery along bottom of chart. 2. Read vertical line up to intersection with selected fluid outlet pressure curve (black curves). Curve slopes from left to right. Follow left to scale and read outlet pressure.

AIR CONSUMPTION

1.7, 17

50 1.40

A

1.4, 14

40 1.12

B

B

1.05, 10.5

To find Pump Air Consumption (m3/min or CFM/min) at a specific delivery (liter/min or gpm) and operating air pressure (MPa/bar/psi): 1. Locate desired delivery along bottom of chart. 2. Read vertical line up to intersection with selected air consumption curve (gray curves). Curve slopes from right to left. Follow right to scale and read air consumption.

0.7, 7

0.35, 3.5

8 15 23 30 38 46 54 GPM l/min

0 2 4 6 8 10 12 14

PUMP DELIVERY (T est FluidNo. 10 Motor Oil)

Wetted Parts · MPa, BAR ·

Page 42 of the Graco Air Regulator (220-569) user manual — AIR CONSUMPTION
Page 42 · click to enlarge
Page 42

Technical Data

3.5:1 Ratio Quiet Senator Pumps, Models 220–565 and 220–568

Maximum Working Pressure 2.45 MPa, 24.5 bar (350 psi) . . Air Operating Range 0.28–0.7 MPa, 2.8–7 bar (40–100 psi) . Air Consumption See Performance Chart Continuous Duty Delivery 65.8 liter/min (17.4 gpm) Pump Cycles Per Liter (gallon) 0.91 (3.44) Maximum Recommended Pump Speed 60 cycles/min Air Inlet 3/4 npsm(f)

Fluid Inlet 1–1/2” npt(f) Fluid Outlet 1” npt Wetted Parts

Model 220–565 Carbon Steel, Stainless Steel, Ultra-High Molecular Weight Polyethylene, Leather, PTFE Model 220–568 Chrome-Plated Stainless Steel, Ultra-High Molecular Weight Polyethylene, Leather, PTFE

CPM

2.45, 24.5 MPa, BAR

PSI

10 21 31 41 52 62

A 0.7 MPa, 7 bar (100 psi) air pressure B 0.49 MPa, 4.9 bar (70 psi) air pressure C 0.28 MPa, 2.8 bar (40 psi) air pressure

Graco Air Regulator (220-569) — PSI diagram (page 42)
Fig. 27

CFM m3/min

2.1, 21

PUMP OUTLET PRESSURE

To find Outlet Pressure (MPa/bar/psi) at a specific delivery (liter/min or gpm) and operating air pressure (MPa/bar/psi): 1. Locate desired delivery along bottom of chart. 2. Read vertical line up to intersection with selected fluid outlet pressure curve (black curves). Curve slopes from left to right. Follow left to scale and read outlet pressure.

1.7, 17

AIR CONSUMPTION

1.4, 14

1.05, 10.5

To find Pump Air Consumption (m3/min or CFM/min) at a specific delivery (liter/min or gpm) and operating air pressure (MPa/bar/psi): 1. Locate desired delivery along bottom of chart. 2. Read vertical line up to intersection with selected air consumption curve (gray curves). Curve slopes from right to left. Follow right to scale and read air consumption.

0.7, 7

0.35, 3.5

11 23 34 46 57 68 GPM l/min

0 3 6 9 12 15 18 21

PUMP DELIVERY (T est FluidNo. 10 Motor Oil)

2.5:1 Ratio Quiet Senator Pumps, Models 220–567 and 220–570

Maximum Working Pressure 1.7 MPa, 17 bar (250 psi) Air Operating Range 0.28–0.7 MPa, 2.8–7 bar (40–100 psi) . Air Consumption See Performance Chart Continuous Duty Delivery 89.9 liter/min (24 gpm) Pump Cycles Per Liter (gallon) 0.66 (2.5) Maximum Recommended Pump Speed 60 cycles/min Air Inlet 3/4 npsm(f)

Fluid Inlet 1–1/2” npt(f) Fluid Outlet 1” npt Wetted Parts

Model 220–567 Carbon Steel, Stainless Steel, Ultra-High Molecular Weight Polyethylene, Leather, PTFE Model 220–570 Chrome-Plated Stainless Steel, Ultra-High Molecular Weight Polyethylene, Leather, PTFE

CPM

CFMm3/min PSI

13 25 38 50 63 75 88

1.7, 17

Graco Air Regulator (220-569) — CPM diagram (page 42)
Fig. 28

A 0.7 MPa, 7 bar (100 psi) air pressure B 0.49 MPa, 4.9 bar (70 psi) air pressure C 0.28 MPa, 2.8 bar (40 psi) air pressure

1.4, 14

PUMP OUTLET PRESSURE

To find Outlet Pressure (MPa/bar/psi) at a specific delivery (liter/min or gpm) and operating air pressure (MPa/bar/psi): 1. Locate desired delivery along bottom of chart. 2. Read vertical line up to intersection with selected fluid outlet pressure curve (black curves). Curve slopes from left to right. Follow left to scale and read outlet pressure.

AIR CONSUMPTION

1.05, 10.5

0.7, 7

To find Pump Air Consumption (m3/min or CFM/min) at a specific delivery (liter/min or gpm) and operating air pressure (MPa/bar/psi): 1. Locate desired delivery along bottom of chart. 2. Read vertical line up to intersection with selected air consumption curve (gray curves). Curve slopes from right to left. Follow right to scale and read air consumption.

0.35, 3.5

0 5 10 15 20 25 30 35

19 38 57 76 95 114 133 GPM l/min

PUMP DELIVERY (T est FluidNo. 10 Motor Oil)

MPa, BAR ·

Page 43 of the Graco Air Regulator (220-569) user manual — B
Page 43 · click to enlarge
Page 43

Technical Data

5:1 Ratio Quiet Senator Pumps, Models 220–566 and 220–569

Maximum Working Pressure 3.4 MPa, 34 bar (500 psi) Air Operating Range 0.28–0.7 MPa, 2.8–7 bar (40–100 psi) . Air Consumption See Performance Chart Continuous Duty Delivery 45.4 liter/min (12 gpm) Pump Cycles Per Liter (gallon) 1.3 (5.0) Maximum Recommended Pump Speed 60 cycles/min Air Inlet 3/4 npsm(f)

Fluid Inlet 1–1/2” npt(f) Fluid Outlet 1” npt Wetted Parts

Model 220–566 Carbon Steel, Stainless Steel, Ultra-High Molecular Weight Polyethylene, Leather, PTFE Model 220–569 Chrome-Plated Stainless Steel, Ultra-High Molecular Weight Polyethylene, Leather, PTFE

CPM

10 20 30 40 50 60 70

PSI

CFM m3/min

3.4, 34

A 0.7 MPa, 7 bar (100 psi) air pressure B 0.49 MPa, 4.9 bar (70 psi) air pressure C 0.28 MPa, 2.8 bar (40 psi) air pressure

3.15, 31.5

A

PUMP OUTLET PRESSURE

2.8, 28 To find Outlet Pressure (MPa/bar/psi) at a specific delivery (liter/min or gpm) and operating air pressure (MPa/bar/psi): 1. Locate desired delivery along bottom of chart. 2. Read vertical line up to intersection with selected fluid outlet pressure curve (black curves). Curve slopes from left to right. Follow left to scale and read outlet pressure.

A

AIR CONSUMPTION

2.45, 24.5

B

2.1, 21

1.7, 17

B

1.4, 14

1.05, 10.5

To find Pump Air Consumption (m3/min or CFM/min) at a specific delivery (liter/min or gpm) and operating air pressure (MPa/bar/psi): 1. Locate desired delivery along bottom of chart. 2. Read vertical line up to intersection with selected air consumption curve (gray curves). Curve slopes from right to left. Follow right to scale and read air consumption.

0.7, 7

0.35, 3.5

8 15 23 30 38 46 54 GPM l/min

0 2 4 6 8 10 12 14

PUMP DELIVERY (T est FluidNo. 10 Motor Oil)

MPa, BAR ·

Page 44 of the Graco Air Regulator (220-569) user manual — Notes
Page 44 · click to enlarge
Page 44

Notes

Page 45 of the Graco Air Regulator (220-569) user manual — B
Page 45 · click to enlarge
Page 45

Technical Data

4:1 Ratio Quiet Bulldog Pumps, Models 220–577, 220–578, and 239–815

Maximum Working Pressure 2.8 MPa, 28 bar (400 psi) Air Operating Range 0.28–0.7 MPa, 2.8–7 bar (40–100 psi) . Air Consumption See Performance Chart Continuous Duty Delivery 90.8 liter/min (24 gpm) Pump Cycles Per Liter (gallon) 0.66 (2.5) Maximum Recommended Pump Speed 60 cycles/min Air Inlet 3/4 npsm(f)

Fluid Inlet 1–1/2” npt(f) Fluid Outlet 1” npt Wetted Parts

Model 220–577 Carbon Steel, Stainless Steel, Ultra-High Molecular Weight Polyethylene, Leather, PTFE Model 220–578 Chrome-Plated Stainless Steel, Ultra-High Molecular Weight Polyethylene, Leather, PTFE

CPM

PSI

8 15 23 30 38 45 53

CFM m3/min

3.4, 34

A 0.7 MPa, 7 bar (100 psi) air pressure B 0.49 MPa, 4.9 bar (70 psi) air pressure C 0.28 MPa, 2.8 bar (40 psi) air pressure

3.15, 31.5

2.8, 28 To find Outlet Pressure (MPa/bar/psi) at a specific delivery (liter/min or gpm) and operating air pressure (MPa/bar/psi): 1. Locate desired delivery along bottom of chart. 2. Read vertical line up to intersection with selected fluid outlet pressure curve (black curves). Curve slopes from left to right. Follow left to scale and read outlet pressure.

A

PUMP OUTLET PRESSURE

A

AIR CONSUMPTION

2.45, 24.5

2.1, 21

B

1.7, 17

B

1.4, 14

To find Pump Air Consumption (m3/min or CFM/min) at a specific delivery (liter/min or gpm) and operating air pressure (MPa/bar/psi): 1. Locate desired delivery along bottom of chart. 2. Read vertical line up to intersection with selected air consumption curve (gray curves). Curve slopes from right to left. Follow right to scale and read air consumption.

1.05, 10.5

0.7, 7

0.35, 3.5

11 23 34 46 57 68 79 GPM l/min

0 3 6 9 12 15 18 21

PUMP DELIVERY (T est FluidNo. 10 Motor Oil)

MPa, BAR ·

Page 46 of the Graco Air Regulator (220-569) user manual — HYDRAULIC OIL CONSUMPTION
Page 46 · click to enlarge
Page 46

Technical Data

Viscount I+ Pumps, Models 236–601 and 236–602

Maximum Working Pressure 3.1 MPa, 31 bar (450 psi) Maximum Hydraulic Working Pressure 10.3 MPa, 103 bar . .

Hydraulic Fluid Inlet 3/4”, (37 flare) Hydraulic Fluid Outlet 7/8”, (37 flare) Wetted Parts

(1500 psi) Continuous Duty Delivery 36.5 liter/min (9.6 gpm) Pump Cycles Per Liter (gallon) 1.64 (6.2) Maximum Recommended Pump Speed 60 cycles/min Maximum Hydraulic Motor Fluid Temperature 54C (134F) .

Model 236–601 Carbon Steel, Stainless Steel, Ultra-High Molecular Weight Polyethylene, Leather, PTFE Model 236–602 Chrome-Plated Stainless Steel, Ultra-High Molecular Weight Polyethylene, Leather, PTFE

CPM

A 10.3 MPa, 103 bar (1500 psi) hydraulic oil pressure B 6.9 MPa, 69 bar (1000 psi) hydraulic oil pressure C 3.4 MPa, 34 bar (500 psi) hydraulic oil pressure

PSI

19 37 56 74

3.4, 34

Graco Air Regulator (220-569) — PSI diagram (page 46)
Fig. 29

3.15, 31.5

HYDRAULIC OIL CONSUMPTION

2.8, 28

To find Outlet Pressure (MPa/bar/psi) at a specific delivery (liter/min or gpm) and operating hydraulic pressure (MPa/bar/ psi): 1. Locate desired delivery along bottom of chart. 2. Read vertical line up to intersection with selected fluid outlet pressure curve (black urves). Curve slopes from left to right. Follow left to scale and read outlet pressure.

PUMP OUTLET PRESSURE

2.45, 24.5

2.1, 21

1.7, 17

1.4, 14

1.05, 10.5

0.7, 7

To find Motor Hydraulic Oil Consumption (liter/min or gpm) at a specific delivery (liter/min or gpm) : 1. Locate desired delivery along bottom of chart. 2. Read vertical line up to intersection with hydraulic oil consumption curve (gray curve). Curve slopes from right to left. Follow right to scale and read hydraulic oil consumption.

0.35, 3.5

11 23 34 46 57 GPM l/min

0 3 6 9 12 15

PUMP DELIVERY (T est FluidNo. 10 Motor Oil)

Viscount I+ Pumps, Models 236–605 and 236–606

Maximum Working Pressure 2.1 MPa, 21 bar (300 psi) Maximum Hydraulic Working Pressure 10.3 MPa, 103 bar . .

Hydraulic Fluid Inlet 3/4”, (37 flare) Hydraulic Fluid Outlet 7/8”, (37 flare) Wetted Parts

(1500 psi) Continuous Duty Delivery 55.6 liter/min (14.7 gpm) Pump Cycles Per Liter (gallon) 1.1 (4.1) Maximum Recommended Pump Speed 60 cycles/min Maximum Hydraulic Motor Fluid Temperature 54C (134F) .

Model 236–605 Carbon Steel, Stainless Steel, Ultra-High Molecular Weight Polyethylene, Leather, PTFE Model 236–606 Chrome-Plated Stainless Steel, Ultra-High Molecular Weight Polyethylene, Leather, PTFE

A 10.3 MPa, 103 bar (1500 psi) hydraulic oil pressure B 6.9 MPa, 69 bar (1000 psi) hydraulic oil pressure C 3.4 MPa, 34 bar (500 psi) hydraulic oil pressure

CPM

PSI

12 25 37 49

2.1, 21

Graco Air Regulator (220-569) — CPM diagram (page 46)
Fig. 30

1.7, 17

5 19.0 To find Outlet Pressure (MPa/bar/psi) at a specific delivery (liter/min or gpm) and operating hydraulic pressure (MPa/bar/ psi): 1. Locate desired delivery along bottom of chart. 2. Read vertical line up to intersection with selected fluid outlet pressure curve (black urves). Curve slopes from left to right. Follow left to scale and read outlet pressure.

HYDRAULIC OIL CONSUMPTION

PUMP OUTLET PRESSURE

1.4, 14

1.05, 10.5

0.7, 7

To find Motor Hydraulic Oil Consumption (liter/min or gpm) at a specific delivery (liter/min or gpm) : 1. Locate desired delivery along bottom of chart. 2. Read vertical line up to intersection with hydraulic oil consumption curve (gray curve). Curve slopes from right to left. Follow right to scale and read hydraulic oil consumption.

0.35, 3.5

0 3 6 9 12 15

11 23 34 46 57 GPM l/min

PUMP DELIVERY (T est FluidNo. 10 Motor Oil)
Show 5 more labels / short text on this page
MPa, BAR · GPM l/min · MPa, BAR · GPM l/min ·
Page 47 of the Graco Air Regulator (220-569) user manual — Manual Change Summary
Page 47 · click to enlarge
Page 47

Technical Data

Viscount I+ Pumps, Models 236–712 and 236–713

Maximum Working Pressure 1.55 MPa, 15.5 bar (225 psi) . . Maximum Hydraulic Working Pressure 10.3 MPa, 103 bar . .

Model 236–712 Carbon Steel, Stainless Steel, Ultra-High Molecular Weight Polyethylene, Leather, PTFE Model 236–713 Chrome-Plated Stainless Steel, Ultra-High Molecular Weight Polyethylene, Leather, PTFE

(1500 psi) Continuous Duty Delivery 75.6 liter/min (20 gpm) Pump Cycles Per Liter (gallon) 0.8 (3.0) Maximum Recommended Pump Speed 60 cycles/min Maximum Hydraulic Motor Fluid Temperature 54C (134F) . Hydraulic Fluid Inlet 3/4”, (37 flare) Hydraulic Fluid Outlet 7/8”, (37 flare)

PTFE PTFE PTFE

is a registered trademark of the DuPont Co. Loctite is a registered trademark of the Loctite Corp.

CPM

12 24 36 48

A 10.3 MPa, 103 bar (1500 psi) hydraulic oil pressure B 6.9 MPa, 69 bar (1000 psi) hydraulic oil pressure C 3.4 MPa, 34 bar (500 psi) hydraulic oil pressure

2.1, 21

1.7, 17

To find Outlet Pressure (MPa/bar/psi) at a specific delivery (liter/min or gpm) and operating hydraulic pressure (MPa/bar/ psi): 1. Locate desired delivery along bottom of chart. 2. Read vertical line up to intersection with selected fluid outlet pressure curve (black urves). Curve slopes from left to right. Follow left to scale and read outlet pressure.

A

1.4, 14

1.05, 10.5

B

0.7, 7

0.35, 3.5

To find Motor Hydraulic Oil Consumption (liter/min or gpm) at a specific delivery (liter/min or gpm) : 1. Locate desired delivery along bottom of chart. 2. Read vertical line up to intersection with hydraulic oil consumption curve (gray curve). Curve slopes from right to left. Follow right to scale and read hydraulic oil consumption.

15 30 46 62 76 GPM l/min

PUMP DELIVERY (T est FluidNo. 10 Motor Oil)

Manual Change Summary

Model 239–815 4:1 Bulldog Pump and Model 239–816 Displacement Pump are added to the manual.

Ref. No.

Part No. Name

Models 220–574 & 220–575 President Pumps, to Series B

Drum Cover Drum Cover Elbow

Model 239–819 3:1 President Pump and Model 239–820 Displacement Pump are added to the manu- al.

Show 17 more labels / short text on this page
Wetted Parts · PSI MPa, BAR · GPM l/min · · · · · · · · · Assembly Changed · Part Status · Old New Added · 202 202 208 · 214–034 237–309 100–839 ·
Page 48 of the Graco Air Regulator (220-569) user manual — Graco Phone Number
Page 48 · click to enlarge
Page 48

The Graco Warranty and Disclaimers

Graco warrants all equipment listed in this manual which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale by an authorized Graco distributor to the original purchaser for use. With the exception of any special extended or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written recommendations.

This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or maintenance or structures, accessories, equipment or materials not supplied by Graco.

This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.

Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.

GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT MANUFACTURED BY GRACO. These items sold, but not manufactured by Graco (such as electric motors, gas engines, switches, hose, etc.), are subject to the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these warranties.

In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the negligence of Graco, or otherwise.

FOR GRACO CANADA CUST OMERS

The parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés à la suite de ou en rapport, directement ou indirectement, avec les procédures concernées.

Graco Phone Number

TO PLACE AN ORDER, contact your Graco distributor, or call this number to identify the distributor closest to you: 1–800–367–4023 Toll Free

All written and visual data contained in this document reflects the latest product information available at the time of publication.

Graco reserves the right to make changes at any time without notice.

Sales Offices: Minneapolis, Detroit, Los Angeles Foreign Offices: Belgium, Canada, England, Korea, France, Germany, Hong Kong, Japan

GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440–1441 PRINTED IN U.S.A. 307–809 July 1987, Revised May 1997

Fix-it

Troubleshooting

Common problems, likely causes, and what to do.

ProblemPossible causeRemedy
Pump output low on both strokes.Restricted air or hydraulic supply lines.Clear any obstructions; be sure all shut- off valves are open; increase pressure, but do not exceed maximum working pressure. p.17
Pump output low on both strokes.Exhausted fluid supply.Refill and reprime pump. p.17
Pump output low on both strokes.Clogged fluid outlet line, valves, etc.Clear. p.17
Pump output low on both strokes.Worn piston packing (15).Replace. See page 20. p.17
Pump output low on only one stroke.Held open or worn check valve.Check and repair. p.17
Pump output low on only one stroke.Worn piston packing (15).Replace. See page 20. p.17
Pump operates erratically.Exhausted fluid supply.Refill and reprime pump. p.17
Pump operates erratically.Held open or worn check valves.Check and repair. p.17
Pump operates erratically.Worn piston packing (15).Replace. See page 20. p.17
Pump operates erratically.Excessive hydraulic fluid supply pres- sure to Viscount motor.See Viscount motor manual. p.17
Pump will not operate.Restricted air or hydraulic supply lines.Clear any obstructions; be sure all shut- off valves are open; increase pressure, but do not exceed maximum working pressure. p.17
Pump will not operate.Exhausted fluid supply.Refill and reprime pump. p.17
Pump will not operate.Clogged fluid outlet line, valves, etc.Clear. p.17
Pump will not operate.Damaged air motor or hydraulic mo- tor.See motor manual. p.17
Pump will not operate.Fluid dried on piston rod (17).Disassemble and clean pump (see page 20). In future, stop pump at bottom of stroke. p.17
Pump will not prime.Suction line clogged.Clear. Flush more frequently. p.17
Pump will not prime.Held open or worn check valves.Check and repair. p.17
Pump will not prime.Piston assembled with wrong nut.Use only the large, round, special nut (12). p.17
Excessive throat leakage.Worn piston rod (17) or throat pack- ings.Replace. See page 20. p.17

Ask about the Graco Air Regulator (220-569)

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Graco Air Regulator (220-569)

Be the first to ask — other owners or our team will answer.

Original document

Graco Air Regulator (220-569) manual PDF

48 pages·819 KB·Heat Pump·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…