GENERATOR PROTECTION

G60 GENERATOR PROTECTION SYSTEM Comprehensive protection for AC generators. 17

The G60 Generator Protection System, a member of the UR Family of protection relays, provides protection for AC generators. It may be used on any size of generator driven by steam, gas, hydraulic or other turbines.

G30 GENERATOR PROTECTION SYSTEM Cost effective protection of small to medium sized generators, includes unit transformer protection. 24

The G30 Generator Protection System, part of the UR family of protection relays, provides protection for small to medium sized generators and for applications needing combined generator and transformer protection.

489 GENERATOR PROTECTION SYSTEM Economical protection, monitoring and metering for generators. 31

The 489 Generator Protection System, a member of the SR Family of protection relays, provides economical protection, monitoring, and metering functions. It can be used as primary or backup protection on synchronous or induction generators of 25, 50, or 60 Hz. It may be applied in primary, backup and co-generator applications.

G650 GENERATOR PROTECTION SYSTEM High performance generation protection relay. 39

The G650 Generator Protection System, a member of the 650 Family of protection relays, provides protection and management capabilities for small to medium sized generators. It combines protection with external communications and a distributed I/O capability.

W650 GENERATOR PROTECTION SYSTEM Advanced wind turbine protection and control system. 47

The W650 Generator Protection System, a member of the 650 Family of protection relays, is a machine controller management device. It may be used to protect and control wind generating machines, and can operate as a packaged generator sets mains failure detector.

MIGII GENERATOR PROTECTION SYSTEM Three-phase protection for small generators. 55

The MIGII, a member of the M II Family of protection relays, provides protection for small generators.

15 www.GEMultilin.com

Page 2 of the GE G30 user manual — G60
Page 2 · click to enlarge
Page 2

GENERATOR Product Selector Guide

GE G30 — GENERATOR Product Selector Guide diagram (page 2)
Fig. 2 · GENERATOR Product Selector Guide

G60

G30 489

G650

W650

MIG II

FEATURES DEVICE MIG W650 G650 489 G30 G60 PROTECTIONOverspeed12Q Speed Switch14Q Distance Backup21QQ Overexcitation24QQQ Synchronism check25QQQQ Phase/Auxiliary Undervoltage27P/APPPP/AP/A Stator Ground (3rt Harmonic)27TNQQQ Ground Undervoltage (Fundamental)27GNQQ Sensitive Directional Power (F/R/LF)32QQQQQ Bearing RTD38QQQ Loss of Excitation Impedance or React. Power40QQQQ Current Unbalance46QQQQQQ Negative Sequence Overcurrent50 2/51 2QQQQ Voltage phase reversal_47 _QQQQQ Inadvertent/Accidental Energization50/27QQQ IOC, Ground/Neutral/Phase/Negative Sequence50G/N/P/QP/NG/N/PG/N/P/QG/N/P/QG/N/PG/N/P IOC, Sensitive Ground50SGQQQQ TOC, Ground/Neutral/Phase/Negative Sequence51G/N/P/QP/NG/N/PG/N/PG/N/PG/N/PG/N/P TOC, Sensitive Ground51SGQQQ Split Phase50SPQQ Voltage Restraint Overcurrent51VQQQQQ Breaker Failure50BFQQQLogic Phase/Auxiliary/Neutral Overvoltage59P/A/NP/A/NP/NPP/A/NP/A/N Ground Overvoltage59GNQQQ 100% Stator Ground64GQQQ Current Directional, Ground/Neutral/Phase/Neg. Seq.67P/G/N/QP/G/NGP/N/QP/N/Q Out of Step Blocking68Q Out of Step Tripping78QQ Voltage Transformer Fuse FailureVTFFQOptionalQQQ Under/Overfrequency81U/O3U & 3O3U & 3O2U & 2OQQ Anti-Islanding Protection/Rate of Change of Frequency 81RQQQ Lockout Functionality86QQ Ground Differential87NQQQQ Differential87SQQ Group Differential87TQ Monitoring of Reactive PowerQQQ CONTROLRemote DisplayQ Redundant Power SupplyOptionalOptionalOption Non-volatile latchesQQ Programmable Elements Programmable LogicQQQQQ FlexElements™QQ Digital Inputs2Up to 32Up to 3278080 Contact Outputs5Up to 16Up to 1666464 Virtual Inputs/OutputsUp to 32Up to 3232/6432/64 Direct Inputs/OutputsUp to 512Up to 5123232 Trip/Close Coil SupervisionOptionalOptionalTripTrip/CloseTrip/Close User-Programmable LEDsQQQQQ User-Programmable Push ButtonsQQQQ User-Programmable Self TestQQ Selector SwitchQQ Digital CountersQQQQQ Digital ElementsQQQQ IRIG-B InputQQQQQ Analog Inputs/OutputsQQQ RTD Inputs1288 MONITORING & METERINGPower FactorQQQQQ CurrentQQQQQQ VoltageQQQQQ Voltage 3rd HarmonicQQ Power - Apparent, Real, ReactiveQQQQQ Current, MW, MVA, Mvar DemandQQQ EnergyQQQQQ FrequencyQQQQQ TemperatureQQQ User Programmable Fault ReportsQQ Event Recorder - Number of Events244794794010241024 Oscillography - Cycles/Sampling Rate24128/64128/6464/1293.5/1693.5/16 Trip CountersQQQQQ Data LoggerQQQQQ COMMUNICATIONSRS232/RS485 PortsQQQQQQ Ethernet CommunicationsQQQQQ Fiber Optic PortOptionalOptionalQQ GE Modem ModBus ProtocolQQQQQQ ModBus User MapQQQQQQ DNP3 ProtocolQQQQQ EGD ProtocolQQ Peer-to-peer communication (Goose)QQQQ IEC 60870-104QQQQ IEC 61850 ProtocolQQQQ Simple Network Time ProtocolQQQ

* For the most current comparison list, access us online at: www.GEMultilin.com/selector/generator.pdf

Ask about the GE G30

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the GE G30

Be the first to ask — other owners or our team will answer.

Original document

GE G30 manual PDF

2 pages·142 KB·Portable Generator·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…