Table of Contents 86 sections Hardware User Manual · Revisions · 1.0 SPECIFICATIONS · 1.1 Technical Specifications · … ShowHide
Hardware User Manualp.1Revisionsp.51.0 SPECIFICATIONSp.71.1 Technical Specificationsp.71.2 Ordering Informationp.102.0 Introductionp.152.1 Inspecting the Package and Productp.152.2 Product Description –p.16Magnum 6K32FC / FRC (Convection cooled - No-fans) Managed Switchp.162.2.1a Magnum 6K32F / FR (Fan cooled) Managed Switch Chassisp.182.2.2 Eight-port SFF fiber modules (6KP8-MTRJ, 6KP8-MLC), 100Mb fiberp.192.2.3 Eight-Port Copper Module, 6KP8-RJ45 (MDIX)p.202.2.3a PoE(Power Inside), model PI6KP8-45RJ (MDIX), 8-port 10/100Mbp.212.2.3b PoE(Power Pass-through), model P6KP8-RJ45 (MDIX), 10/100Mb 8-portp.212.2.4 Six-Port “4 + 2”Combo Modules,p.224@ 10/100 RJ-45 and 2@100Mb fiber (ST or SC)p.222.2.5 Four-Port 10 Mb mm Fiber ST Modulesp.232.2.6 Gigabit (1000Mbps) port modulesp.232.2.7 Packet Prioritization, 802.1p QOSp.242.2.8 Frame Buffering and Flow Controlp.242.2.9 Managed Network Software (MNS-6K) for Magnum 6K32F Seriesp.252.3 Features and Benefitsp.262.4 Applicationsp.273.0 Installationp.323.1 Locating Magnum 6K32F Series Switchesp.323.2.1 Connecting Fiber Optic ST-type, “twist-lock”p.333.2.2 Connecting Fiber Optic SC-type, "Snap-In"p.343.2.3 Connecting Single-Mode Fiber Opticp.343.2.4 Connecting Twisted Pair (RJ-45,CAT3, CAT5, Unshielded or Shielded)p.343.2.5 Connecting Twisted Pair (CAT-5e or better, Unshielded or Shielded)p.353.2.6 Gigabit SFP (Small Form-factor Pluggable) Optical Transceiversp.363.2.7 Power Budget Calculations for Magnum 6K32F Series PM’s with Fiber Mediap.373.3 Table-Top or Shelf Mountingp.393.3.1 Rack-mounting (for 19” RETMA racks) Magnum 6K32F & 6K32FCp.393.3.2 Rack-mounting, Reverse version of the Magnum 6K32FR & 6K32FRCp.40Fig 3.3.2 Reverse Magnum 6K32F Seriesp.403.4 Powering the Magnum 6K32F Series Managed Switchp.403.4.1 Alarm Contacts for monitoring internal power, and Software Trapsp.413.5 6K32F Series Port Module (6KPM) Installationp.423.5.1 Preparation for Installing and Removing 6KPMsp.423.5.2 Installing 6KPM Cards in the Magnum 6K32F Seriesp.443.5.3 Removing 6KPM Cardsp.463.6 Connecting the Console Terminal to Magnum 6K32F Series (Management)p.483.6.1 RS-232 (DB-9) Console Com port (Serial port) pin assignments.p.484.1 Switching Functionalityp.504.2 Status LEDsp.514.3 Auto-Cross (MDIX)Auto-negotiation, for 10/100Mbps RJ-45 portsp.514.4 Flow-control, IEEE 802.3x standardp.525.0 Magnum 6K32F Series Managed Switch Port Modulesp.535.1 Inspecting the Package and Productp.535.2 6KPM Module Descriptionp.535.2.1 6KP6-RJMST, 4@10/100Mbps RJ-45 and 2@100Mb multi-mode FX-ST “twist lock” Combo Modulep.545.2.1a 6KP6-RJ10ST, 4@10/100Mbps RJ-45 and 2@10Mb multi-mode FX-ST “twist lock” Combo Modulep.545.2.1b 6KP4-F10ST, 4@10Mb multi-mode FX-ST “twist lock” Modulep.555.2.1c 6KP4-FLSTFX, 2@10Mb and 2@100Mb multi-mode FX-ST “twist lock” Modulep.555.2.2. 6KP6-RJMSC 4@10/100Mbps RJ-45 and 2@100Mb multi-mode FX-SCp.56“snap-in” Fiber connectorp.565.2.3 6KP6-RJSSC 4@ 10/100Mbps RJ-45 Ports and 2@100Mbps single-mode FX-SC-type, “snap-in” connectorp.565.2.4 6KP6-RJSSCL 4 @ 10/100 Mb copper port and 2@100Mbps single-modep.57FX-SC-type, “snap-in” connectorp.575.2.4a 6KP6-RJ10ST 4 @ 10/100 Mb copper port and 2@10Mbps multi-modep.57FL-ST-type, “twist-lock” connectorp.575.2.5 6KP8-MTRJ, 8 @100Mb multi-mode FX , MTRJ Small-Form-factorp.585.2.5a 6KP6-MT10ST, 4 @100Mb multi-mode FX , MTRJ Small-Form-p.58Factor and 2@ 10Mb Multi-mode ST-Fiber portp.585.2.6 6KP8-45MT, 4@ 10/100Mbps RJ-45 and 4@100Mb multi-mode FX , MTRJ Small-Form-Factorp.595.2.7 6KP8-MLC, 8 ports @ 100Mbps multi-modep.59LC Small-Form Factorp.595.2.8 6KP8-45LC, Combo 4@ 100Mbps multi-mode -LC small-formp.60factor and 4@ 10/100 Mbps RJ-45 Connectorp.605.2.9 6KP8-RJ45 (Twisted Pair), 10/100Mb 8-Portp.605.2.10a. PoE (Power Pass-through), model P6KP8V-RJ45 (MDIX), 10/100Mb 8-portp.615.2.10b. PoE(Power Inside), model PI6KP8-45RJ (MDIX), 10/100Mb 8-portp.625.2.11 6KP8-45-2MT, 6@ 10/100Mbps RJ-45 and 2@100Mb multi-mode FX , MTRJ Small-Form-Factorp.635.2.11a 6KP8-45-2LC, 6@ 10/100Mbps RJ-45 and 2@100Mb single-mode FX , LC Small-Form-Factorp.645.2.12 GBIC-SXSC Gigabit fiber(1000Mb), multi-mode SC Connectorp.645.2.12a GBPM-2OTX (Two Gigabit option)p.655.2.12b GBIC-LXSC Gigabit fiber (1000Mb), multi-mode SC Connectorp.655.2.13 6KM-BLNKp.666.0 TROUBLESHOOTINGp.666.1 Before Calling for Assistancep.676.2 When Calling for Assistancep.676.3 Return Material Authorization (RMA) Procedurep.686.4 Shipping and Packaging Informationp.69APPENDIX A: WARRANTY INFORMATIONp.69APPENDIX B : Internal DC Power Supply Optionsp.70
Page 1 of the GarrettCom Managed Ethernet Switch (6K32FR) user manual — email support@garrettcom.com
Page 1 · click to enlarge
Page 1

Magnum 6K32F, 6K32FR, 6K32FC &

Industrial Managed Switch

GarrettCom Managed Ethernet Switch (6K32FR) — Magnum 6K32F, 6K32FR, 6K32FC & diagram (page 1)
Fig. 1 · Magnum 6K32F, 6K32FR, 6K32FC &
GarrettCom Managed Ethernet Switch (6K32FR) — Magnum 6K32F, 6K32FR, 6K32FC & diagram (page 1)
Fig. 2 · Magnum 6K32F, 6K32FR, 6K32FC &

Hardware User Manual

Installation and User Guide

GarrettCom Managed Ethernet Switch (6K32FR) — Hardware User Manual diagram (page 1)
Fig. 3 · Hardware User Manual

6K32FRC

Websitehttp://www.GarrettCom.com

email [email protected]

47823 Westinghouse Dr. Fremont, CA 94539-7437

GarrettCom, Inc.

Corporate Headquarters · Phone (510) 438-9071 · Fax (510) 438-9072

Page 2 of the GarrettCom Managed Ethernet Switch (6K32FR) user manual — Managed Switch Hardware
Page 2 · click to enlarge
Page 2

Magnum ™ 6K32F, 6K32FR, 6K32FC & 6K32FRC

Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08)

GarrettCom, Magnum, Personal Switch, S-Ring, Link-Loss-Learn, Converter

Switch and Convenient Switch are trademarks and Personal Hub is a registered

shall render all warranties null and void. If problems are experienced

user serviceable parts. Attempted service by unauthorized personnel

with Magnum 6K32F Series of Switch products, consult Section 6,

GarrettCom, Inc. reserves the right to change specifications, performance

Copyright © 2008 GarrettCom, Inc. All rights reserved. No part of this

publication may be reproduced without prior written permission from

Managed Switch Hardware

Installation and User Guide

UL is a registered trademark of Underwriters Laboratories

Part #84-00103Z (Rev. A)

characteristics and/or model offerings without notice.

NEBS is a trademark of Telcordia Technologies

Troubleshooting, of this User Guide.

Ethernet is a trademark of Xerox Corporation

Printed in the United States of America.

trademark of GarrettCom, Inc.

GarrettCom, Inc.

Trademarks

Page 3 of the GarrettCom Managed Ethernet Switch (6K32FR) user manual — Phone (510) 438-9071
Page 3 · click to enlarge
Page 3

Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08)

This equipment generates, uses and can radiate frequency energy and if

not installed and used properly, that is in strict accordance with the manufacturer's

instructions, may cause interference to radio communication. It has been tested

and found to comply with the limits for a Class A computing device in accordance

with the specifications in Subpart J of Part 15 of FCC rules, which are designed to

provide reasonable protection against such interference when operated in a

commercial environment. Operation of this equipment in a residential area is

likely to cause interference, in which case the user at his own expense will be

Cet appareil respecte toutes les exigences du Réglement sur le matériel du

Please use the mailing address, phone and fax numbers and email address listed

required to take whatever measures may be required to correct the interference.

This Class A digital apparatus meets all requirements of the Canadian

Websitehttp://www.GarrettCom.com

Radio Frequency Interference Statement

email support@garrettcom.com

below: GarrettCom, Inc.

47823Westinghouse Dr. Fremont, CA 94539-7437

Phone (510) 438-9071

Interference-Causing Equipment Regulations.

Canada. Cet appareil est Classe A.

Show 4 more labels / short text on this page
Federal Communications Commission · Fax (510) 438-9072 · Canadian Emission · Contacting GarrettCom, Inc
Page 4 of the GarrettCom Managed Ethernet Switch (6K32FR) user manual — Table of contents
Page 4 · click to enlarge
Page 4

Table of contents

Hardware User Manualp.1Revisionsp.51.0 SPECIFICATIONSp.71.1 Technical Specificationsp.71.2 Ordering Informationp.102.0 Introductionp.152.1 Inspecting the Package and Productp.152.2 Product Description –p.16Magnum 6K32FC / FRC (Convection cooled - No-fans) Managed Switchp.162.2.1a Magnum 6K32F / FR (Fan cooled) Managed Switch Chassisp.182.2.2 Eight-port SFF fiber modules (6KP8-MTRJ, 6KP8-MLC), 100Mb fiberp.192.2.3 Eight-Port Copper Module, 6KP8-RJ45 (MDIX)p.202.2.3a PoE(Power Inside), model PI6KP8-45RJ (MDIX), 8-port 10/100Mbp.212.2.3b PoE(Power Pass-through), model P6KP8-RJ45 (MDIX), 10/100Mb 8-portp.212.2.4 Six-Port “4 + 2”Combo Modules,p.224@ 10/100 RJ-45 and 2@100Mb fiber (ST or SC)p.222.2.5 Four-Port 10 Mb mm Fiber ST Modulesp.232.2.6 Gigabit (1000Mbps) port modulesp.232.2.7 Packet Prioritization, 802.1p QOSp.242.2.8 Frame Buffering and Flow Controlp.242.2.9 Managed Network Software (MNS-6K) for Magnum 6K32F Seriesp.252.3 Features and Benefitsp.262.4 Applicationsp.273.0 Installationp.323.1 Locating Magnum 6K32F Series Switchesp.323.2.1 Connecting Fiber Optic ST-type, “twist-lock”p.333.2.2 Connecting Fiber Optic SC-type, "Snap-In"p.343.2.3 Connecting Single-Mode Fiber Opticp.343.2.4 Connecting Twisted Pair (RJ-45,CAT3, CAT5, Unshielded or Shielded)p.343.2.5 Connecting Twisted Pair (CAT-5e or better, Unshielded or Shielded)p.353.2.6 Gigabit SFP (Small Form-factor Pluggable) Optical Transceiversp.363.2.7 Power Budget Calculations for Magnum 6K32F Series PM’s with Fiber Mediap.373.3 Table-Top or Shelf Mountingp.393.3.1 Rack-mounting (for 19” RETMA racks) Magnum 6K32F & 6K32FCp.393.3.2 Rack-mounting, Reverse version of the Magnum 6K32FR & 6K32FRCp.40Fig 3.3.2 Reverse Magnum 6K32F Seriesp.403.4 Powering the Magnum 6K32F Series Managed Switchp.403.4.1 Alarm Contacts for monitoring internal power, and Software Trapsp.413.5 6K32F Series Port Module (6KPM) Installationp.423.5.1 Preparation for Installing and Removing 6KPMsp.423.5.2 Installing 6KPM Cards in the Magnum 6K32F Seriesp.443.5.3 Removing 6KPM Cardsp.463.6 Connecting the Console Terminal to Magnum 6K32F Series (Management)p.483.6.1 RS-232 (DB-9) Console Com port (Serial port) pin assignments.p.484.1 Switching Functionalityp.504.2 Status LEDsp.514.3 Auto-Cross (MDIX)Auto-negotiation, for 10/100Mbps RJ-45 portsp.514.4 Flow-control, IEEE 802.3x standardp.525.0 Magnum 6K32F Series Managed Switch Port Modulesp.535.1 Inspecting the Package and Productp.535.2 6KPM Module Descriptionp.535.2.1 6KP6-RJMST, 4@10/100Mbps RJ-45 and 2@100Mb multi-mode FX-ST “twist lock” Combo Modulep.545.2.1a 6KP6-RJ10ST, 4@10/100Mbps RJ-45 and 2@10Mb multi-mode FX-ST “twist lock” Combo Modulep.545.2.1b 6KP4-F10ST, 4@10Mb multi-mode FX-ST “twist lock” Modulep.555.2.1c 6KP4-FLSTFX, 2@10Mb and 2@100Mb multi-mode FX-ST “twist lock” Modulep.555.2.2. 6KP6-RJMSC 4@10/100Mbps RJ-45 and 2@100Mb multi-mode FX-SCp.56“snap-in” Fiber connectorp.565.2.3 6KP6-RJSSC 4@ 10/100Mbps RJ-45 Ports and 2@100Mbps single-mode FX-SC-type, “snap-in” connectorp.565.2.4 6KP6-RJSSCL 4 @ 10/100 Mb copper port and 2@100Mbps single-modep.57FX-SC-type, “snap-in” connectorp.575.2.4a 6KP6-RJ10ST 4 @ 10/100 Mb copper port and 2@10Mbps multi-modep.57FL-ST-type, “twist-lock” connectorp.575.2.5 6KP8-MTRJ, 8 @100Mb multi-mode FX , MTRJ Small-Form-factorp.585.2.5a 6KP6-MT10ST, 4 @100Mb multi-mode FX , MTRJ Small-Form-p.58Factor and 2@ 10Mb Multi-mode ST-Fiber portp.585.2.6 6KP8-45MT, 4@ 10/100Mbps RJ-45 and 4@100Mb multi-mode FX , MTRJ Small-Form-Factorp.595.2.7 6KP8-MLC, 8 ports @ 100Mbps multi-modep.59LC Small-Form Factorp.595.2.8 6KP8-45LC, Combo 4@ 100Mbps multi-mode -LC small-formp.60factor and 4@ 10/100 Mbps RJ-45 Connectorp.605.2.9 6KP8-RJ45 (Twisted Pair), 10/100Mb 8-Portp.605.2.10a. PoE (Power Pass-through), model P6KP8V-RJ45 (MDIX), 10/100Mb 8-portp.615.2.10b. PoE(Power Inside), model PI6KP8-45RJ (MDIX), 10/100Mb 8-portp.625.2.11 6KP8-45-2MT, 6@ 10/100Mbps RJ-45 and 2@100Mb multi-mode FX , MTRJ Small-Form-Factorp.635.2.11a 6KP8-45-2LC, 6@ 10/100Mbps RJ-45 and 2@100Mb single-mode FX , LC Small-Form-Factorp.645.2.12 GBIC-SXSC Gigabit fiber(1000Mb), multi-mode SC Connectorp.645.2.12a GBPM-2OTX (Two Gigabit option)p.655.2.12b GBIC-LXSC Gigabit fiber (1000Mb), multi-mode SC Connectorp.655.2.13 6KM-BLNKp.666.0 TROUBLESHOOTINGp.666.1 Before Calling for Assistancep.676.2 When Calling for Assistancep.676.3 Return Material Authorization (RMA) Procedurep.686.4 Shipping and Packaging Informationp.69APPENDIX A: WARRANTY INFORMATIONp.69APPENDIX B : Internal DC Power Supply Optionsp.70
Page 5 of the GarrettCom Managed Ethernet Switch (6K32FR) user manual — 6.1 Before Calling for Assistance.............................................................61
Page 5 · click to enlarge
Page 5

4.4 Flow-control, IEEE 802.3x standard 46

5.0 6K32F SERIES MANAGED SWITCH PORT MODULES 47 5.1 Inspecting the Package and Product 47

5.2 6KPM Module Description 47 5.2.1 6KP6-RJMST multi-mode FX-ST “twist lock” Module 48 5.2.1a 6KP6-RJ10ST multi-mode FX-ST “twist lock” Combo 48 5.2.1b 6KP4-F10ST multi-mode FX-ST “twist lock” Module 49 5.2.1c 6KP4-FLSTFX multi-mode FX-ST “twist lock” Module 49 5.2.2. 6KP6-RJMSC multi-mode FX-SC “snap-in” Module 50 5.2.3 6KP6-RJSSC Mbps single-mode FX-SC-type, “snap-in” 50 5.2.4 6KP6-RJSSCL FX-SC-type, “snap-in” connector 51 5.2.4a 6KP6-RJ10ST FL-ST-type, “twist-lock” connector 51 5.2.5 6KP8-MTRJJ Small-Form-factor 52 5.2.5a 6KP6-MT10STmode FX Factor 52 5.2.6 6KP8-45MT MTRJ Small-Form-Factor 53 5.2.7 6KP8-MLC LC connector Small- 53 5.2.8 6KP8-45LC 10/100 Mbps RJ-45 Connector 54 5.2.9 6KP8-RJ45 (Twisted Pair), 10/100Mb 8-Port 54 5.2.10a. PoE (Power Pass-through)P6KP8V-RJ45 (MDIX) 55 5.2.10b. PoE(Power Inside), model PI6KP8-45RJ (MDIX) 56 5.2.11 6KP8-45-2MT MTRJ Small-Form-Factor 57 5.2.11a 6KP8-45-2LC single-mode FX , LC Small-Form-Factor 58 5.2.12 GBIC-SXSC Gigabit fiber(1000Mb), multi-mode SC 58

5.2.12a GBPM-2OTX (Two Gigabit option) 59 5.2.12b GBIC-LXSC Gigabit fiber (1000Mb), multi-mode SC 59 5.2.13 6KM-BLNK 60 6.0 TROUBLESHOOTING 60

6.1 Before Calling for Assistance 61

6.2 When Calling for Assistance..............................................................61

6.3 Return Material Authorization (RMA) Procedure..............................62

6.4 Shipping and Packaging Information.................................................63

APPENDIX A: WARRANTY INFORMATION .........................................63

APPENDIX B : INTERNAL DC POWER SUPPLY OPTIONS.................64

APPENDIX C: INTERNAL DC DUAL-SOURCE POWER OPTION ......67

Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08)

Rev A 05/08 : Initial release of the Magnum 6K32F Series manual.

Revisions

Page 6 of the GarrettCom Managed Ethernet Switch (6K32FR) user manual — OVERVIEW
Page 6 · click to enlarge
Page 6

Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08)

GarrettCom, Inc. offers the premium-quality Magnum™ line of

INDUSTRIAL connectivity products with industry-standard functionality and

built-in fiber configurability. Magnum products are designed for use in

demanding Industrial Grade, Carrier Class, POWER UTILITY and OEM

4K-Series Switches, 100 and 10 Mbps, copper ports with optional fiber port, with auto-negotiating

Quad-Series Fiber Switches, 100 & 10Mbps, fiber and copper ports, mixed-speed and mixed-media

mP62 and P62F “Outdoor” Ethernet SwitchES, for temperature uncontrolled locations, 6 10/100

Personal Hubs, 10Mb series 8-port + AUI, stackable to 5 high, + optional BNC of fiber port 8 or 9-

6K-Series Managed Field Switches, Gigabit, 100 and 10 Mbps, fiber and copper ports, mix-and

APR, 07

Media Converters, 10Mb and 100Mb series, All media combinations, incl. fiber ST, SC, mm.,

Personal Hubs, 100Mb or 10/100Mb 8-port, with 2 switched ports (1 fiber built in)

INDUSTRIAL NETWORKING PRODUCTS

"DESIGNED AND MANUFACTURED IN THE USA"

The Magnum Line

applications where reliability is a primary consideration.

Stackable Concentrators, SNMP optional, 13-Ports

OVERVIEW

Dual Speed 8-port and 16-port, 10/100 auto-sensing HUBS

Repeater Port Modules (RPMs), 6 types for Ethernet media

Mixed-Media Fiber Hub, 16-port, 10/100 auto-sensing

The “X-line” of configurable MiXed Media products:

DX-Series Serial Device Routers, Ethernet and Serial

port and 4 or 5-Port Personal Hubs, w/ man. up-link sw.

match. Features SFF fiber and DC power in 1U units.

and 2 100Mb fiber ports, can be connected in strings

8 port dual-speed, Auto-negotiable with fiber option

Mini-Concentrators, 7 Ports, Repeaters, 2-Ports

Personal Switches, 10/100/1000Mb

COAX Transceivers, 10Mb series

types, full switching performance.

full switching performance.

single mode

Page 7 of the GarrettCom Managed Ethernet Switch (6K32FR) user manual — 1.0 SPECIFICATIONS
Page 7 · click to enlarge
Page 7
Switching Processing TypeStore and Forward with IEEE 802.3x full-

Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08)

Latency: 6 μs + packet time (TX – TX, TX – FX, FX – FX, TX - G, G - G)

100BASE-FX, full-duplex, single-mode - 20.0 km (65,620 ft)

100BASE-FX, full-duplex, Long Reach - 40.0 km (131,240 ft)

Unshielded twisted pair - 100 m (328 ft)

10BASE-FL multi-mode fiber optic - 2 km (6,562 ft)

10BASE-FL single-mode fiber optic - 10 km (32,810 ft)

10BASE-T (CAT 3, 4, 5 UTP) - 100 m (328 ft)

100BASE-TX (CAT 5 UTP) - 100 m (328 ft)

Packet buffer size240KB for 10/100 and 120KB for 1000Mb

100BASE-FX, half-duplex, multi-mode - 412 m (1350 ft)

100BASE-FX, full-duplex, multi-mode - 2.0 km (6,562 ft)

Shielded twisted pair - 150 m (492 ft)

Shielded twisted pair - 150 m (492 ft)

100BASE-FX, half-duplex, single-mode - 412 m (1350 ft)

Address Table Capacity4K node, self-learning with address aging

Throughput with 16 10/100 and 4 Glink max- 8.33M pps (Transmit)

IEEE 802.3z1000BASE-X Ethernet(Auto-negotiation)

Maximum Standard Fast Ethernet Segment Lengths:

IEEE 802.1xPort based Network access control
Ethernet V1.0/V2.0 IEEE 802.310BASE-T,
IEEE 802.3adLink Aggregation (Trunking)

Maximum 10 Mbps Ethernet Segment Lengths

duplex flow -control, non-blocking

IEEE 802.1wRapid Spanning tree protocol
Data Rate10Mbps,100Mbps and 1000Mbps
IEEE 802.3u100Base-TX, 100BASE-FX
IEEE 802.3afPower over Ethernet(PoE)

Back plane- 2.66Gb/s per slot

IEEE 802.3ab1000BASE-X Ethernet
IEEE 802.1dSpanning tree protocol
Gigabit Ethernet1,488,000 pps

Filtering / Forwarding Rate:

Network Standards and Compliance

Fast Ethernet148,800 pps
IEEE 802.1pPriority protocol
IEEE 802.1qVLAN Tagging

1.1 Technical Specifications

IEEE 802.3xFlow Control

Ethernet:14,880 pps

1.0 SPECIFICATIONS

Performance

Page 8 of the GarrettCom Managed Ethernet Switch (6K32FR) user manual — 1.0 SPECIFICATIONS
Page 8 · click to enlarge
Page 8

with adjacent manual ON-OFF switch (optional if no Alarms Cont.)

DB-9 for RS-232 “ null-modem“ cable (sometimes called an X-modem cable)

Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08)

EnclosureRugged High strength metal. Suitable for stand-alone

1000BASE-T (CAT5E or higher is recommended) - 100 m

30 watts max (fully-loaded copper only modules)

1000BASE-SX, full-duplex, multi-mode(62.5μm cable) - 220m

1000BASE-SX, full-duplex, multi-mode(50μm cable) - 550m

1000BASE-LX, full-duplex, single-mode(9μm cable) -5Km

Conformal Coating (Humidity Protection) option: Request quote

Power Consumption60 watts max (fully-loaded with fiber modules)
AC Power ConnectorIEC-type, male recessed at rear of chassis,

IEC 60068 “Type Test” ratings:- -40°to 185°F (-40°to 85°C)

Ambient Relative Humidity5% to 95% (non-condensing)

UL 60950 “Component Parts” temp. ratings: 140° F (60°C)

Maximum Standard Gigabit Ethernet Segment Lengths:

-48VDC Power Input Voltage-36 to -70 VDC
LKSteady ON when media link is operational
24VDC Power Input Voltage20 to 40VDC
Dimensions1.70in. H x 17.0in. W x 9.0in. D
Altitude-200 to 13,000 ft. (-60 to 4000m)

4.32cm H x 43.2cm W x 22.9cm D Cooling method: Fan cooled, @ 25 cfm ea.

Input Voltage100 to 240 VAC (auto-ranging)

OFF = Half-Duplex Mode

Input Frequency47 to 63 Hz (auto-ranging)
FDX/HDXON = Full-Duplex Mode

MTRJ-type Small Form Factor (SFF)

LC-type Small Form Factor (SFF)

ACTON with receiver port activity

Fuse required for replacement- 1 Amp

Fiber connector types supported:

100/10ON = 100Mbps speed OFF = 10 Mbps

Fuse Required – 2 Amps

DC Power Supply (Options)

LEDsPer Port
Show 8 more labels / short text on this page
or rack-mounting · Management Console connector · ST-type (twist-lock) · Operating Environment · Power Supply (Internal) · SC-type (snap-in) · GBIC modules · Packaging
Page 9 of the GarrettCom Managed Ethernet Switch (6K32FR) user manual — Cooling Method-
Page 9 · click to enlarge
Page 9

For (Optional) DC internal power supplies at –48VDC, 24VDC and 125VDC,

The Alarm Contact option is offered as a configuration option. The alarms can be

The copper daughter board has MDI-MDIX Auto-crossover on all the RJ-45

ports which eliminates the use of cross-over cable between the devices. Also

IEEE 1613 Classs 2 Environmental Standard for Electric Power Substations.

initiated through two normally closed Form-C contacts, one loss of power alarm

port-specific user settings (such as FDX or HDX, copper 10/100 speed) can

including Dual Source options (for continuity of operation when either of the DC

6K32FC / 6K32FRC(Reverse)- Convection cooled (No fans) Static Thermal design techniques

See also Note for Power Substations in Section 3.2.4, 3.6.1, and 5.2.9

IEC61850 EMC and Operating Conditions Class C for Power Substations

http://www.garrettcom.com/techsupport/insertion_guides/6k32fcg.pdf (6K32F /

Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08)

UL listed (UL60950), cUL, CE, Emissions meet FCC Part 15, Class A

http://www.garrettcom.com/techsupport/insertion_guides/6k32fccg.pdf

NEBS L3 and ETSI Compliant, NEMA TS-2 for traffic control

WarrantyThree years, return to factory Made in USA
Power Consumptionsame as for AC models, see above
125VDC and 100VDC Input Voltage88 to 300VDC Fuse Required – 1 Amp

and one software alarm through user selectable software traps.

For a Configuration Guide, see the GarrettCom web site at

6K32F/ 6K32FR(Reverse)- Fan cooled (3 fans inside)

Email mktg@GarrettCom.com for additional details.

input sources are interrupted), see Appendices B and C.

Std. Terminal Block“ -, GND, + ”

be fixed using software commands.

Relay Alarm Contact (Optional)

Per-port MDI or MDIX on RJ-45

Fuse Required – 3 Amps

Cooling Method-

(6K32FC / FRC)

FR)

Agency Approvals

Page 10 of the GarrettCom Managed Ethernet Switch (6K32FR) user manual — MODEL DESCRIPTION
Page 10 · click to enlarge
Page 10

10/100/1000Mb fiber and copper connector types, max. 32 ports 10/100 or 8 ports Gigabit max., or combination.

10/100/1000Mb fiber and/or copper connector types, max. 32 ports 10/100 fiber or copper or 8 Gigabit ports.

Magnum 6K32FRC-125VDC:Same as 6K32FC except reverse &power input is 125VDC

Magnum 6K32F or 6K32FR (Reverse model) 32-10/100 RJ-45 ports or 8 Gigabit ports

Magnum 6K32FR-48VDC:Same as 6K32F except reverse and power input is –48VDC

Magnum 6K32FR-125VDC:Same as 6K32F except reverse and power input is 125VDC

Magnum 6K32FRC-48VDC:Same as 6K32FC except reverse &power input is –48VDC

Each Magnum 6K32F Series base unit has four configurable port modules slot to

Magnum 6K32FR-24VDC:Same as 6K32F except reverse and power input is 24VDC

Magnum 6K32FRC-24VDC:Same as 6K32FC except reverse &power input is 24VDC

6KP4-FXSC “2+2” 100Mb Fiber module, w/ four 100Mb 2km FX SC connectors

managed switch with four modular slots which may be configured with a selection of

managed switch, with four modular slots which may be configured with a selection of

6KP4-FLSTFX “2+2” ST Fiber module, w/ two 100Mb and two 10Mb ports, 2km 6KP6-RJMST “4+2” module, w/four RJ-45 ports and two 2km mm FX SC’s

Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08)

6KP4-F10ST “2+2” 10Mb Fiber module, w/ four 10Mb 2km FL ST connectors

6KP4-FXST “2+2” ST Fiber module, w/ s, four 100Mb 2km FX ST connectors

6KP6-RJSSC “4+2” module, w/four RJ-45 ports and two 20km Sgl.m FX SC’s

6KP6-RJSSCL “4+2” module, w/four RJ-45 ports and two 40km Sgl.m FX SC’s

Magnum 6K32FC or 6K32FRC (Reverse model)- Convection cooled (no fans)

6KP8-RJ45 TP Module, w/eight 10/100Mbps auto-negotiating RJ-45 ports

6KP6-RJMSC “4+2” module, w/four RJ-45 ports and two 2km mm FX ST‘s

Magnum 6K32FC-125VDC:Same as 6K32FC except power input is 125VDC

Magnum 6K32FC-48VDC:Same as 6K32FC except power input is –48VDC

Magnum 6K32F-125VDC:Same as 6K32F except power input is 125VDC

Magnum 6K32FC-24VDC:Same as 6K32FC except power input is 24VDC

Magnum 6K32F-48VDC:Same as 6K32F except power input is –48VDC

Magnum 6K32F Series Port Modules (all modules include front panel)

Magnum 6K32F-24VDC:Same as 6K32F except power input is 24VDC

Magnum Managed Switch

be configured with any one of the port modules listed below:

MODEL DESCRIPTION

1.2 Ordering Information

Configuration Options:

Page 11 of the GarrettCom Managed Ethernet Switch (6K32FR) user manual — 1.2 Ordering Information
Page 11 · click to enlarge
Page 11

Gigabit Modules, fixed ports, using Small form factor (SFP) transceivers (all modules

6KP5-G4RJ “G+4” module, with one GBIC open transceiver and four 10/100 RJ-45

6KP3-G2SC “G+2” module, with one GBIC transceiver and two 100Mb 2km FX SC

GBPM-2OTX Two port Gigabit module provides two GBIC open transceiver ports for

GBIC-SXSC GBIC transceiver module for use in GBPM-xOTX. One 1000BASE-SX

GBIC-ZXSC40 GBIC transceiver module for use in GBPM-xOTX. One 1000BASE-ZX

GBIC-ZXSC70 GBIC transceiver module for use in GBPM-xOTX. One 1000BASE-ZX

GBIC-ZXSC120 GBIC transceiver module for use in GBPM-xOTX. One 1000BASE-ZX

6KP8-45-2MT “6+2” module, w/six RJ-45 ports and two 2km mm MTRJ connectors

6KP8-45-2SLC “6+2” module, w/six RJ-45 ports and two 100Mb 15km sgl. mode FX LC connectors

6KP2-2GSFP two port in one slot Gigabit 6K module, uses one 6K slot and provides

provides one SFP Gb Fiber (1000BASE-SX Multi-mode) port and one

6KP1-1GSFP one port in one slot Gigabit 6K module, uses one 6K slot and provides

6KP1-1GCU one port in one slot Gigabit 6K module, uses one 6K slot and provides

GBPM-COTX One slot Gigabit 6K module provides one GBIC open transceiver port

6KP8-45MLC “4+4” module, w/four RJ-45 ports and four 2km mm LC connectors

6KP8-45SLC “4+4” module, w/four RJ-45 ports and four 15km Sm LC connectors

GBIC-LXSC10 GBIC transceiver module for use in GBPM-xOTX. One 1000BASE-

GBIC-LXSC25 GBIC transceiver module for use in GBPM-xOTX. One 1000BASE-

6KP8-45MT “4+4” module, w/four RJ-45 ports and four 2km mm FX MT-RJ’s

Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08)

6KP6-MT10ST “4+2” module, w/four MTRJ ports and two 10Mb 2km FL ST’s 6KP6-RJ10ST “4+2” module, w/four RJ-45 ports and two 10Mb 2km FL ST ‘s

6KP2-1GCU1SFP two port in one slot Gigabit 6K module, uses one 6K slot and

LX/LH port with 1310nm single mode SC(10km) fiber connector

LX/LH port with 1310nm single mode SC(25km) fiber connector

6KP8-MTRJ SFF Fiber module, w/eight 100Mb mm FX MT-RJ connectors

6KP8-SLC SFF Fiber module, w/eight 100Mbps sgl-m FX LC connectors

6KP8-MLC SFF Fiber module, w/eight 100Mbps mm FX LC connectors

port with 1550nm, single. mode SC(120km) fiber connector.

Gigabit Options (Modules using GBIC) (all modules include front panel)

port with 1550nm, single mode SC(40km) fiber connector

port with 1550nm, single. mode SC(70km) fiber connector.

one Gb Copper (1000 BASE-RJ45 Auto-negotiating) port

two SFP Gb Fiber (1000BASE-SX Multi-mode) ports

Gb Copper (1000BASE-RJ45 Auto-negotiating) port

one SFP Gb Fiber (1000BASE-SX Multi-mode) port

for a user-selectable GBIC transceiver module

a user-selectable GBIC transceiver module

port with multimode SC fiber connector

fiber ports connectors · include front panel) · connectors

Page 12 of the GarrettCom Managed Ethernet Switch (6K32FR) user manual — 1.2 Ordering Information
Page 12 · click to enlarge
Page 12

6KP2-1CU1SX two-port in one slot Gigabit 6K module, uses one 6K slot and provides one Gb Fiber SXSC (1000BASE-SX Multi-mode) port and one Gb

MNS-6K License(Management software)- Preloaded with the latest firmware, license

6KP5-1CU4RJ “G+4” module, with one GBIC copper (Auto-negotiating) transceiver

6KP5-1CU4MT “G+4” module, with one GBIC copper (Auto-negotiating) transceiver and four 100Mb MTRJ Fx-Multi-mode connectors

6KP3-1CU2FXT “G+2” module, with one GBIC copper (Auto-negotiating) transceiver and four 100Mb ST Fx-Multi-mode connectors

6KP2-2GSX two-port in one slot Gigabit 6K module, uses one 6K slot and provides

6KP2-2GCU two-port in one slot Gigabit 6K module, uses one 6K slot and provides

6KM-BLNK Blank cover for one 6K32F Series module slot opening in a Magnum

CONSOLE USB Console attachment cable, serial to USB, cable with one DB9 for the

managed Switch and a USB interface for the USB connector to a PC.

modem “ connection (sometimes called an Xmodem cable), used to

costs included with each 6K base unit.

Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08)

6K32F Series chassis CONSOLE CBL Industry standard serial cable, DB-9 connectors for RS-232 “ null-

GBIC-TP GBIC transceiver module for use in GBPM-xOTX. One 802.3ab

connect a PC or a character terminal to the Management port.

two Gb Copper (1000BASE-RJ45 Auto-negotiating) ports

two Gb Fiber SXSC (1000BASE-SX Multi-mode) ports

Modules with Gb, not using GBICs (all modules include front panel)

Copper (1000BASE-RJ45 Auto-negotiating) port

1000BASE-T port with RJ-45 connector

and four 10/100 RJ-45 connectors

Page 13 of the GarrettCom Managed Ethernet Switch (6K32FR) user manual — 1.2 Ordering Information
Page 13 · click to enlarge
Page 13

6K32F Series PoE Modules with 48VDC Pass-Through Configuration options: All module slots of 6K32F Series switch with 48VDC power

input may be configured with a PoE Module (typical configuration has slot A loaded

P6KP8-RJ45 8 port PoE module for 6Ks with 48vdc PS, w/eight PoE power source 10/100 auto-negotiating auto cross RJ-45 ports. P6KP8-45RJ “4+4” port PoE module for 6Ks with 48vdc PS, w/four PoE power

source and two normal RJ-45 10/100 ports +two100 Mb 2km mm FX

P6KP8-45MT “4+4” port PoE module for 6Ks with 48vdc PS, w/four PoE power

P6KP8-45MLC “4+4” port PoE module for 6Ks with 48vdc PS, w/four PoE power

P6KP8-45SLC “4+4” port PoE module for 6Ks with 48vdc PS, w/four PoE power

P6KP8-45-2MT “6+2” port PoE module for 6Ks with 48vdc PS, w/four PoE power

P6KP8-452SLC “6+2” port PoE module for 6Ks with 48vdc PS, w/four PoE power

P6KP6-RJMST “4+2” port PoE module for 6Ks with 48vdc PS, w/four PoE power

P6KP6-RJMSC “4+2” port PoE module for 6Ks with 48vdc PS, w/four PoE power

P6KP6-RJSSC “4+2” port PoE module for 6Ks with 48vdc PS, w/four PoE power

P6KP6-RJSSCL “4+2” port PoE module for 6Ks with 48vdc PS, w/four PoE power

P6KP6-RJ10ST “4+2” port PoE module for 6Ks with 48vdc PS, w/four PoE power

Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08)

source and four 10/100 auto-negotiating auto cross RJ-45 ports

source and four 100 Mb 2km mm FX MTRJ connectors

source and four 100 Mb 15km Sm FX LC connectors

source and four 100 Mb 2km mm FX LC connectors

source and four 100 Mb 15km sm FX LC connectors

source and two 100 Mb 2km mm FX ST connectors

source and two 100 Mb 2km mm FX SC connectors

source and two 100 Mb 20km sm FX SC connectors

source and two 100 Mb 40km sm FX SC connectors

source and two 10 Mb 2km sm FL ST connectors

first with PoE module)

MTRJ connectors

Page 14 of the GarrettCom Managed Ethernet Switch (6K32FR) user manual — 1.2 Ordering Information
Page 14 · click to enlarge
Page 14

6KAC-PoE-PS Power supply for PoE to 4 ports, 60 watts, mounts inside of a full-width

6K125VDC-PoE-PS Power supply for PoE to 4 ports, 60 watts, mounts inside of a full- width rack-mount 6K switch with 125VDC power input.

source and two normal RJ-45 10/100 ports +two100 Mb 2km mm FX

Configuration optionsonly one A, B, C or D (left to right) module slot of 6K32F

PI6KP8-45RJ “4+4” port PoE module for 6Ks with 48vdc PS, w/four PoE power

PI6KP8-45MT “4+4” port PoE module for 6Ks with 48vdc PS, w/four PoE power

PI6KP8-45MLC “4+4” port PoE module for 6Ks with 48vdc PS, w/four PoE power

PI6KP8-45SLC “4+4” port PoE module for 6Ks with 48vdc PS, w/four PoE power

PI6KP8-45-2MT “6+2” port PoE module for 6Ks with 48vdc PS, w/four PoE power

PI6KP8-452SLC “6+2” port PoE module for 6Ks with 48vdc PS, w/four PoE power

PI6KP6-RJMST “4+2” port PoE module for 6Ks with 48vdc PS, w/four PoE power

PI6KP6-RJMSC “4+2” port PoE module for 6Ks with 48vdc PS, w/four PoE power

PI6KP6-RJSSC “4+2” port PoE module for 6Ks with 48vdc PS, w/four PoE power

PI6KP6-RJSSCL “4+2” port PoE module for 6Ks with 48vdc PS, w/four PoE power

PI6KP6-RJ10ST “4+2” port PoE module for 6Ks with 48vdc PS, w/four PoE power

Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08)

Series switch with 48VDC power input may be configured with a PoE Module

source and four 10/100 auto-negotiating auto cross RJ-45 ports

6K32F Series PoE Modules with 48VDC Power Inside NOTE: For configuring in 6K Switches having AC /125VDC power input

GarrettCom, Inc. reserves the right to change specifications, performance

source and four 100 Mb 2km mm FX MTRJ connectors

source and four 100 Mb 2km mm FX LC connectors

source and four 100 Mb 15km sm FX LC connectors

source and four 100 Mb 15km sm FX LC connectors

source and two 100 Mb 2km mm FX ST connectors

source and two 100 Mb 2km mm FX SC connectors

source and two 100 Mb 20km sm FX SC connectors

source and two 100 Mb 40km sm FX SC connectors

source and two 10 Mb 2km sm FL ST connectors

rack-mount 6K switch with AC power input.

(typical configuration has slot A loaded with PoE module)

characteristics and/or model offerings without notice.

MTRJ connectors

Page 15 of the GarrettCom Managed Ethernet Switch (6K32FR) user manual — 2.0 Introduction
Page 15 · click to enlarge
Page 15

1 Magnum 6K32F, 6K32FR, 6K32FC or 6K32FRC Managed Switch, base

In the event there are items missing or damaged, contact the party from whom

product; notify the carrier of any damage that you believe occurred during shipment or

delivery. Inspect the contents of this package for any signs of damage and ensure that

unit (configured with user-selected port module option in modular slot)

Remove the items from the shipping container. Be sure to keep the shipping

shipping container if possible. Refer to Section 6, Troubleshooting, for specific return

Examine the shipping container for obvious damage prior to installing this

Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08)

you purchased the product. If the unit needs to be returned, please use the original

1 AC Power Cord (U.S. and other 115 VAC only)

container should you need to re-ship the unit at a later date.

1 Set of metal “Ears” for 19” rack mounting

1 Installation and User Guide (this manual)

2.1 Inspecting the Package and Product

This package should contain:

the items listed below are included.

2.0 Introduction

procedures.

Page 16 of the GarrettCom Managed Ethernet Switch (6K32FR) user manual — Switch
Page 16 · click to enlarge
Page 16

All of the Magnum 6K32F Series of Ethernet Switches comply with IEC61850

multiple secured managed features is able to handle industry-standard IEEE 802.1p QOS

Magnum 6K32FC / FRC (Convection cooled - No-fans) Managed

convection cooling thermal design techniques to minimize heat build up providing an

efficient, economical, highly reliable, long lived and secure Ethernet solution for heavy

6K32FC/FRC is proudly offered with modularity, port density (up to 32 ports max.) and

The Magnum 6K32F Series has the flexibility to configure up to thirty two 100Mb Fiber

ports, or thirty two 10/100Mb Copper ports, or eight Gigabit(1000Mb) ports providing a

The preloaded robust and intuitive MNS-6K Managed Network firmware with

The Magnum 6K32FC/FRC Managed Switches are specially designed with

duty Industrial, Power sub-stations and temp-uncontrolled outdoor applications.

combination of options to handle high and low bandwidth applications efficiently. The

prioritization and non-blocking wire speed on all ports. It provides high performance

managed switch family, with additional modularity in all 4 slots providing increased

Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08)

Figure 2.2.1aA typical 6K32FC Switch front view, 4 RJ-45 10/100 ports, 2 ST

various Power over Ethernet (PoE) modules add the advantage for Magnum 6K32F

Specially designed and enclosed in a standard and “Reverse” aluminum case, the

The Magnum 6K32F Series are derived from the highly successful 6K

Series users of providing secure and economical solutions for critical remote

10Mb FL ports, 8 ST 100Mb FX ports and 2 RJ45 Gigabit ports.

and IEEE1613 Utility Automation and other industry standards.

configurability provided by the numerous 6KP modules available.

security in a 1U rack-mount package.

2.2 Product Description –

applications.

Switch

Page 17 of the GarrettCom Managed Ethernet Switch (6K32FR) user manual — (CLI)
Page 17 · click to enlarge
Page 17

features include SNMPv3, SSL/SSH, 802.1X, TACACS+, Port Security, and Tagged

The port flexibility feature is achieved using a large family of 6K modules with

product adaptable to almost any network need. Modules are factory configured in a base

the Magnum 6K32F Series for heavy-duty applications. The chassis rack mounting style

of the 6K32FR / FRC is “Reverse” (with the ports and LEDs and the power-input and the

switching services for both “smooth” streaming and “bursty” data traffic. For redundant

Magnum 6K-Switches thus enabling an economical solution without Routers or Layer 3

http://www.garrettcom.com/techsupport/software/userguides/mns6k_webmanual.p

including -48VDC, 24VDC, 125/110 VDC, 250VDC and universal 110/240VAC target

management console connector all in the rear and a duplicate set of LEDs in the front).

LANs it offers S-ring, RS-Ring, Link-Loss-Learn, STP and RSTP. Optional Security

Evolving mixed-media requirements for 10Mb and 100Mb fiber, copper, and

various copper and fiber capabilities built-in. High fiber port density is achieved using

combinations. Fixed one and two Gigabit fiber and copper modules are available along

chassis (or may be changed in the field by trained technicians) to adapt the unit to the

Rack widths accommodated include standard 19” RETMA, ETSI, and 23” Telco. The

VLANs as well as a secure, user friendly web based option. IGMP Snooping and

1000Mb Gigabit Ethernet can be simply and reliably handled by the Magnum 6K32F

networks from 2 to over 100km are accommodated. Each module can support up to 8

Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08)

IGMP-L2 features provide most IGMP Layer 3 functions for multicast traffic with

http://www.garrettcom.com/techsupport/software/userguides/mns6k_CLI.pdf

with modules for use with GBIC and SFP fiber and copper transceivers making this

See MNS-6K materials for further details about management software.

Small Form Factor LC or MTRJ connectors and multimode and single-mode fiber

The strong aluminum case and wide selection of power-input options

ports of fiber or RJ-45 copper connectors as well as various fiber and copper

user’s specific Ethernet media requirements.

switches for streaming video applications.

Series products.

(CLI)

df (web)

Page 18 of the GarrettCom Managed Ethernet Switch (6K32FR) user manual — 2.2.1a Magnum 6K32F / FR (Fan cooled) Managed Switch Chassis
Page 18 · click to enlarge
Page 18

play hardware operation, 802.1p packet prioritization in hardware, and industry-standard

Figure 2.2.1b6K32F front view, configured for 2 RJ-45 Gigabit ports, 4 ST 100Mb

of ease of use through “Secure Web based management and scripts feature to manage the

6K32F switch remotely”. The 6K32F loaded with robust MNS-6K firmware is specially

capability to meet any 10, 100 or Gigabit requirement effectively, satisfying almost any

through port security, Radius X, Tacacs+ and Snmpv3 and provide an effective solution

AC, and –48VDC power input options are designed for Telco environments, while the

applications, the Magnum 6K32FC / FRC provides secure, high performance plug-and-

managed networks software functionality with plenty of secure and remote monitoring

The high port density and fan cooled Magnum 6K32F / FR was designed for

reliability. This rack mountable managed switch comes with a wide variety of AC/DC

The modular option with four slots exemplifies this managed switch’s extra

demand for complex Ethernet networks. The bandwidth demand of Triple Play “voice-

heavy duty Carrier class and Industrial applications that require high port density and

The fan-cooled 6K32F/FR Series have the same four modular configurable

slots as the 6K32FC/FRC models and offer the same flexibility of configuration. (see

features of this managed switch. The switch allows the users to secure their network

Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08)

24VDC is designed for Industrial/Control Room applications. The 125 & 250VDC

Designed primarily for use in harsh, un-controlled temperature industrial

GarrettCom Managed Ethernet Switch (6K32FR) — 2.2.1a Magnum 6K32F / FR (Fan cooled) Managed Switch Chassis diagram (page 18)
Fig. 4 · 2.2.1a Magnum 6K32F / FR (Fan cooled) Managed Switch…

2.2.1a Magnum 6K32F / FR (Fan cooled) Managed Switch Chassis

The growing demand of security and “Ease of use” are the other adding

secure devices which save in cost, rack space and run cool to provide long term

options to deliver effective and efficient solutions tailored to specific industrial

FX ports, 8 MTRJ 100Mb FX ports and 8 LC 100Mb FX ports

features, all in convenient 1U rack-mount packages.

data-video” over Ethernet will be handled efficiently.

versions are for power sub stations applications.

applications.

above).

Page 19 of the GarrettCom Managed Ethernet Switch (6K32FR) user manual — fiber
Page 19 · click to enlarge
Page 19

The Magnum 6K32F is preloaded with robust and intuitive MNS-6K Managed

GarrettCom Managed Ethernet Switch (6K32FR) — 2.2.2 Eight-port SFF fiber modules (6KP8-MTRJ, 6KP8-MLC), 100Mb fiber diagram (page 19)
Fig. 5 · 2.2.2 Eight-port SFF fiber modules (6KP8-MTRJ, 6KP8-…

designed to meet the future demand of Ethernet requirements with cost-effective secure

LEDs are on the front and the available ports along with the power supply area found on

Network Software to handle industry-standard IEEE 802.1p QOS prioritization and non-

both “smooth” streaming and “bursty” data traffic. For redundant LANs, it offers S-ring,

2.2.2 Eight-port SFF fiber modules (6KP8-MTRJ, 6KP8-MLC), 100Mb

The 100Mb fiber eight-port modules for the Magnum 6K32F Series normally

There are three LED’s per fiber port. The Link (LK) LED indicates “ready for

solutions. The Magnum 6K32F is also available in a Reverse model option, where the

blocking wire speed on all ports. It provides high performance switching services for

In an eight-port SFF fiber port module, all of the fiber ports are of the same

speed (100Mb), mode, and connector type. Models that are available with Small Form

Factor (SFF) are multi-mode MT-RJ or LC-type connectors, and single-mode LC-type

performance. Using the 6K32F Series MNS software, the user may select full- or half-

Software Manual for the flexibility to adapt to any FDX or HDX type of Fast Ethernet

operation” on that port when lit, the F/H LED indicates operation in full-duplex mode

The modules which may be configured and used in the modular slots of the

duplex mode per-port through the set-up of the software (See the Magnum MNS-6K

Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08)

SSL/SSH, 802.1X, TACACS+, Port Security, and Tagged VLANs. See MNS-6K

are set (factory default) to operate in full-duplex mode for best fiber distance and

RS-Ring, Link-Loss-Learn, STP and RSTP. Security features include SNMPv3,

the rear side. This configuration is mostly used for the carrier-class market.

Fig.2.2.2SFF Fiber Port Modules, 6KP8-MTRJ (left) and

6KP8-MLC or -SLC (right)

Magnum 6K32F Series are described here.

materials for further details about software.

GarrettCom Managed Ethernet Switch (6K32FR) — 2.2.2 Eight-port SFF fiber modules (6KP8-MTRJ, 6KP8-MLC), 100Mb diagram (page 19)
Fig. 6 · 2.2.2 Eight-port SFF fiber modules (6KP8-MTRJ, 6KP8-…

fiber

connectors.

devices).

Page 20 of the GarrettCom Managed Ethernet Switch (6K32FR) user manual — 2.2.3 Eight-Port Copper Module, 6KP8-RJ45 (MDIX)
Page 20 · click to enlarge
Page 20

(See Section 4.3 for auto-negotiation and MDIX details). The auto-crossover feature will

Mb speed when OFF (when auto-negotiation is not disabled). The FDX/HDX LED is ON

cable must be connected into an RJ-45 port and the Link (LK) indicator for that port must

Activity on the port. A fiber cable must be connected into a SFF port and the Link (LK)

GarrettCom Managed Ethernet Switch (6K32FR) — 2.2.3 Eight-Port Copper Module, 6KP8-RJ45 (MDIX) diagram (page 20)
Fig. 7 · 2.2.3 Eight-Port Copper Module, 6KP8-RJ45 (MDIX)

the connector and two separate. The LK (Link) LED indicates “ready for operation” on

that port when lit. The blinking ACT (Activity) LED indicates receiving Activity on that

port when lit. The 10/100 LED indicates operation at 100Mb speed when ON and at 10

Using the 6K8-Series (MNS-6K) management software, the user may disable

auto-negotiation and fix the desired operation of each RJ-45 port. User may select 10Mb

indicator for that port must be ON (indicating there is a powered-up device at the other

ts a mode and speed to match the device at

On the model 6KP8-RJ45 module, there are four LEDs for each port, two in

to indicate full-duplex operation and OFF to indicate half-duplex mode. A twisted pair

automatically determine the other side of the connection to make the connection, and

or 100Mb speed and full- or half-duplex mode per-port as per user requirement. (See

Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08)

when ON (half-duplex when OFF), and the blinking ACT LED indicates receiving

end of the cable) in order for a LK LED to provide valid indications of operating

be ON (indicating there is a powered-up device at the other end of the cable)

to provide valid indications of operating conditions on that port.

2.2.3 Eight-Port Copper Module, 6KP8-RJ45 (MDIX)

Magnum MNS-6K Software Manual for details info.).

10 or 100Mb speed in full- or half- duplex mode, i.e., each independently selec

the other end of the twisted pair cable.

eliminate the need of a cross-over cable.

provides eight 10/100Mb switched

crossover(MDIX) for operation at

The 6K-Series 8-port Copper port

N-way auto-negotiating, and auto-

RJ-45 ports. The 10/100Mb

switched ports normally (as

default setting) are indepen

conditions on that port.

Show 5 more labels / short text on this page
in order for · dently · a · module, model 6KP8-RJ45, · a LK LED
Page 21 of the GarrettCom Managed Ethernet Switch (6K32FR) user manual — 2.2.3a PoE(Power Inside), model PI6KP8-45RJ (MDIX), 8-port 10/100Mb
Page 21 · click to enlarge
Page 21

PoE LED is ON when connected properly to an 803.af compliant PD device on that port.

except they have capability of providing power on each port to power up the PD devices,

The New PoE RJ-45 ports act similar to regular RJ-45 ports, except they have capability

standard. Only 4 x RJ-45 (10/100) ports max. support POE(Power Inside) option in one

rack mounted 6K-unit. The power inside PoE option is factory configured and equipped

POE module are also available with mix –n-match with fiber modules. Please check the

When non-PoE devices are connected, the PoE LED is OFF. Operation of Ethernet data

LINK and ACTIVITY LEDS are combined on the PoE modules into one LED

2.2.3b PoE(Power Pass-through), model P6KP8-RJ45 (MDIX), 10/100Mb 8-port

The PoE (Power-pass-through) RJ-45 ports act similar to regular RJ-45 ports,

(10/100) ports. Each port requires at least 15watts to power up the PoE PD devices max.

of providing power on each port to power up the PD devices, per the IEEE802.3af PoE

regular (non-PoE) RJ-45 modules as shown in Fig 2. When the PoE port is in use, the

with the necessary power option to support four 802.3af PoE pd devices. The 4-RJ45

per the IEEE802.3af PoE standard. The Power Pass-through PoE modules are totally

Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08)

GarrettCom Managed Ethernet Switch (6K32FR) — 2.2.3a PoE(Power Inside), model PI6KP8-45RJ (MDIX), 8-port 10/100Mb diagram (page 21)
Fig. 8 · 2.2.3a PoE(Power Inside), model PI6KP8-45RJ (MDIX),…

The LEDs on 6KP8-RJ45- PoE module are slightly different compared to

dependent upon the powerful -48VDC input power supply to support more RJ-45

2.2.3a PoE(Power Inside), model PI6KP8-45RJ (MDIX), 8-port 10/100Mb

-48vdc power input. The PoE modules are also available with mix & match fiber

One PoE module can be configured in the A, B, C or D slot of any 6K s with

ordering information Sec.1.2. for all the various PI6K PoE modules option.

that is marked as LINK/ACT, as shown in the diagram.

traffic is not affected by PoE.

Page 22 of the GarrettCom Managed Ethernet Switch (6K32FR) user manual — 2.2.4 Six-Port “4 + 2”Combo Modules,
Page 22 · click to enlarge
Page 22

PoE LED is ON when connected properly to an 803.af compliant PD device on that port.

On Magnum “4+2” Combo modules, there are four LED’s for each RJ-45 port,

When non-PoE devices are connected, the PoE LED is OFF. Operation of Ethernet data

LINK and ACTIVITY LEDS are combined on the PoE modules into one LED

GarrettCom Managed Ethernet Switch (6K32FR) — 2.2.4 Six-Port “4 + 2”Combo Modules, diagram (page 22)
Fig. 9 · 2.2.4 Six-Port “4 + 2”Combo Modules,

The four RJ-45 ports operate just like the 8-port copper module with the auto-

operate at 100Mbps full-duplex (default). User mode control per port through the MNS

modules in Section 2.2.2 above. Color-coding on the panel of the module shows which

The 4@ RJ-45 + 2@ 10 Mb ST operation of the SFF fiber and the RJ-45 half

of the module is as described for those port types above. For detailed information about

regular (non-PoE) RJ-45 modules as shown in Fig 2. When the PoE port is in use, the

mode fiber ST, SC or single mode SC or Long Reach SC ports. For ports numbering,

cross (MDIX) feature to eliminate the use of cross-over cables, and the two fiber ports

which indicate status the same as described for the 6KP8-RJ45 in Section 2.2.3 above.

modules. Please check the ordering information Sec.1.2 for all the various P6K PoE

available as four 10/100 switched RJ-45 copper ports and two 100Mb switched multi-

Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08)

The LEDs on 6KP8-RJ45- PoE module are slightly different compared to

The combo six-port modules are combinations of copper and fiber media,

The Magnum Combo six-port modules are also available with 4@ MTRJ

100Mb mm SFF fiber and 2@10Mb fiber mm ST ports, and with 4@ RJ45 10/100

The fiber port’s LEDs indicate status the same way as described for the SFF fiber

ports 1,3,5,7 are copper, ports 2 and 6 are fiber, ports 4 and 8 are not present.

4@ 10/100 RJ-45 and 2@100Mb fiber (ST or SC)

10Mb mm ST fiber half of the module, see Section 2.2.5.

that is marked as LINK/ACT, as shown in the diagram.

2.2.4 Six-Port “4 + 2”Combo Modules,

GarrettCom Managed Ethernet Switch (6K32FR) — 2.2.4 Six-Port “4 + 2”Combo Modules, diagram (page 22)
Fig. 10 · 2.2.4 Six-Port “4 + 2”Combo Modules,

copper and 2@10Mb fiber mm ST ports.

traffic is not affected by PoE.

LEDs belong to which port.

software is also the same.

modules option.

Page 23 of the GarrettCom Managed Ethernet Switch (6K32FR) user manual — 2.2.6 Gigabit (1000Mbps) port modules
Page 23 · click to enlarge
Page 23

below in the figure.

fiber modules except for the 10Mb speed. For port numbering, ports 1, 2, 5, 6 are present,

The Magnum 6K32F Series switches offer wide options for Gigabit speed with

multiple choices for the modular slot. The new Magnum 6K32F Series can be configured

modular slot comes in a couple of different configurations. The two Gigabit port modules

duplex, which allows the Magnum 6K32F Series Switch to connect to any 10Mb hub or

media converter or almost any other device with a 10Mb fiber Ethernet port. User mode

standard, i.e., 2km distance for multi-mode fiber. (Single-mode for up to 10Km distance

have been offered as GBPM-2OTX (fiber or RJ-45), whereas the single Gigabit module

GarrettCom Managed Ethernet Switch (6K32FR) — 2.2.5 Four-Port 10 Mb mm Fiber ST Modules diagram (page 23)
Fig. 11 · 2.2.5 Four-Port 10 Mb mm Fiber ST Modules

1@ 1000Mb Fiber SC + 2@ 100Mb SC 1@ 1000Mb Fiber SC + 4@10/ 100Mb

modules. The fiber ports support fiber cabling distances according to the 10BASE-FL

with eight Gigabit ports (copper or Fiber) maximum. The Gigabit port option for the

The 6K32F Series modules provide a GBIC opening for insertion of industry-standard

GBICs to provide Gigabit (Gb) media flexibility. GBIC models are available for both

The 4port @10Mb ST fiber modules behave the same as the 8@100Mb ST

Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08)

ports 3, 4, 7, 8 are not present. The default setup on the 10Mb fiber module is half-

comes in flavors of G+4(10/100 RJ-45 ports) or G+2 (100Mb fiber ports) as shown

multi-mode (550m) and single-mode (10, 25, 40, 70, 120)km fiber options, and for

control per port through the MNS software is the same as the other 6K32F Series

GarrettCom Managed Ethernet Switch (6K32FR) — 2.2.5 Four-Port 10 Mb mm Fiber ST Modules diagram (page 23)
Fig. 12 · 2.2.5 Four-Port 10 Mb mm Fiber ST Modules

2.2.5 Four-Port 10 Mb mm Fiber ST Modules

Gigabit copper as well with new models appearing often.

may be available as a special order configuration).

2.2.6 Gigabit (1000Mbps) port modules

GarrettCom Managed Ethernet Switch (6K32FR) — 2.2.6 Gigabit (1000Mbps) port modules diagram (page 23)
Fig. 13 · 2.2.6 Gigabit (1000Mbps) port modules
Page 24 of the GarrettCom Managed Ethernet Switch (6K32FR) user manual — .2.7 Packet Prioritization, 802.1p QOS 2
Page 24 · click to enlarge
Page 24

The 1000Mb Gigabit fiber-port modules on the Magnum 6K32F Series

switches are normally set (factory default) to operate at AUTO mode for best fiber

distance and performance. The 1000Mbps SC fiber-optic module on the Gigabit -SX and

s LEDs that indicate LK (Link status)

r application-specific priority control by the

of bad packets, enabling all

There are two LEDs mounted on each Gigabit port module. The Gigabit fiber

priority tagged packets according to the 802.1p standard. In addition to hardware suppor

for QOS, the MNS software (R3) supports two priority queues that can be shared across

"express") impose minimal frame latency, they will also permit bad frames to propagate

fragment frames (which are a result of late collisions) to be forwarded which add to the

is that more bandwidth is available for good packets when the traffic

port is by default configured to AUTO mode, and can be fixed at 1000Mbps speed full-

Magnum 6K32F Series are store-and-forward switches. Each frame (or pack

out to the Ethernet segments connected. The "cut-through" technique permits collision

collisions and bad packets are more likely when traffic is heavy, the result of store-and-

Quality of Service means providing consistent predictable data delivery to

The Magnum 6K32F Series switching hardware supports the IEEE 802.1p

is loaded into the Switch’s memory and inspected before forwarding can occur. This

technique ensures that all forwarded frames are of a valid length and have the correct

Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08)

For Dual Gigabit modules option, please check page#60 for details info.

users from datagram paths that go all across a network. As a LAN device, the Mag

standard and fulfills its role in support of QOS, giving packet processing priority to

network traffic. Since there is no way to filter frames with a bad CRC (the entire fr

must be present in order for CRC to be calculated), the result of indiscriminate cut-

through forwarding is greater traffic congestion, especially at peak activity. Since

Gigabit-LX transceivers are compatible with the IEEE 802.3z Gigabit standards.

OS degradation while it is handling

While other switching technologies (such as "cut-through" or

CRC, i.e., are good packets. This eliminates the propagation

il dwidth to be used for valid information.

duplex mode at any time. The Gigabit fiber port ha

and ACT (receiving activity) on that port when lit.

.2.7 Packet Prioritization, 802.1p QOS 2

.2.8 2 Frame Buffering and Flow Control

6K32F Series can do its part to prevent any Q

traffic through its ports and buffers.

the eight levels of defined packet priorities fo

user through software configuration settings.

of the ava able ban

load is t. greates

Show 6 more labels / short text on this page
t · et) · num · ame · forward operation · Ethernet
Page 25 of the GarrettCom Managed Ethernet Switch (6K32FR) user manual — .2.9 Managed Network Software (MNS-6K) for Magnum 6K32F Series 2
Page 25 · click to enlarge
Page 25

.2.9 Managed Network Software (MNS-6K) for Magnum 6K32F Series 2

4.0), which allows the configuration of the Magnum 6Ks as a Managed Switch and other

All MNS-6K software information, including new releases and upgrades related to MNS-

www.GarrettCom.com/techsupport/index.htm#software and look for Magnum

by forcing a collision signal on all receiving half-duplex ports to stop incoming

Magnum 6K32F Series Switches come with licensed MNS-6K Firmware (Rel

space is low, the Switch sends industry standard (full-duplex only) PAUSE packets ou

ntation and latest information on GarrettCom proprietary

When the Magnum 6K32F Series Switch detects that its free buffer queue

Another feature implemented in Magnum 6K32F Series Switches is a collis

based flow-control mechanism (when operating half-duplex only). When the Switch

detects that its free buffer queue space is low, the Switch prevents more frames from

Software enabled features. For additional information about MNS-6K, see the Magn

Magnum MNS-6K Operator Training – This interactive training software

gives the basic and advanced information about the Magnum MNS-6K management

Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08)

6K-Series MNS Software User guide in pdf format, a separate document normally m.com/ accessed via your web-browser, at ftp://ftp.garrettco

http://www.garrettcom.com/techsupport/software/upgrade_mns6k.pdf

the devices sending packets to cause “flow control”. This tells the sending devices

test For upgrading the Magnum 6K32F Series Switch to its la

temporarily stop sending traffic, which allows a traffic catch-up to occur wit

packets. Then, normal packet buffering and processing resumes.

Magnum 6K-Firmware, follow the steps and instruction provided on -

6K software, can be accessed and download from GarrettCom’s FTP site.

For further information, please email: support@GarrettCom.com.

or FTP cl p.GarrettCom.com ient program by ft using

software and is a useful tool for a first time user.

passwordm6kuser
userm6kuser

MIBs for SNMP visit

MNS-6K info..

affic.

Show 9 more labels / short text on this page
t to · ion- · um · to · hout · Alternatively, for docume · dropping · entering · tr
Page 26 of the GarrettCom Managed Ethernet Switch (6K32FR) user manual — 2.3 Features and Benefits
Page 26 · click to enlarge
Page 26

at once) performance with standard Managed Networks Software (MNS-6K) included.

Magnum 6K32F Series Switches provide non-blocking (all ports can run at full speed

They are typically used in LAN traffic centers with 24 10/100Mb ports or one or two

Gigabit ports for backbone connections where managed network services are desired.

processing priority to priority tagged packets according to the IEEE 802.1p standard.

Small Form Factor (SFF) and GBIC fiber connectors. RJ-45 10/100 ports can also be

The 1U Magnum 6K32F Series chassis has 4 slots for port configurations. A family of

The standard rack mounting provides Ethernet ports and status LEDs in front, service

Standard AC power input has an IEC plug and is auto-ranging for worldwide use. For

special applications, models with –48VDC or 24VDC or 125VDC are available. Dual

Fiber ports take more power than copper ports, but the Magnum 6K32F Series design

provides for this with heavy-duty components. The ambient temperature can be up to

Protocol, RSTP, LLL, S-Ring Redundancy Mgr, (optional) multi-level QoS, Port and

Tag-based VLANs, GVRP, IGMP Snooping, SNMPc GUI support; BootP and DHCP

For port- and application-specific priorities, the QoS software may be configured by

Source DC input can also be selected and configured on the DC power input models.

Release 4.0 includes SNMP, Secure Web Management, RMON, CLI, Port Security;

single-mode; 10 Mb, 100Mb and 1000Mb speed; full-and half-duplex; and classic

„ Modular design for port flexibility, in a 1U space-saving rack-mount package

2, 4, 6 or 8 port modules allows the user to select the desired mix of port types and speeds. There are over 20 different modules in the family to choose from. The port

modules are normally factory installed and tested, but may be changed in the field.

Standard 19’ rack mount brackets are included, with ETSI and 23” Telco optional.

„ Heavy-duty design for Telco (NEBS tested) and other industrial environments

naturally include fiber ports and support mixes of the following; multi-mode and

„ Rack-mounting may be standard or “reverse”, 19 inch or ETSI or 23” Telco

55°C. „ MNS-6K licensed Network Management Software included, S-Ring/RS-Ring

Port Mirroring; Port Settings Control; Telnet, TFTP, FTP support, Spanning Tree

Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08)

connections (power input and management console) in the rear. “Reverse” rack

mounting provides status LEDs in front and all cabling connections in the rear.

„ Standard AC power input, -48VDC or 24VDC or 125VDC input is optional

The Magnum 6K32F Series switching hardware supports QoS, giving packet

Magnum 6K32F Series Managed Switches are designed with modular slots to

„ Switching services includes 802.1p QoS packet prioritization

„ Managed switching for high performance Ethernet LANs

configured in the mix of port types.

2.3 Features and Benefits

the user.

„ Features Fiber-Built-In · optional

Page 27 of the GarrettCom Managed Ethernet Switch (6K32FR) user manual — 2.4 Applications
Page 27 · click to enlarge
Page 27

requirements. The 6K32F Series also offers MNS-6K management software loaded with

variety of Power sub-stations applications including, Industrials and temp. un-controlled,

secure VLAN- performance upgrades to departmental networks, and LAN traffic centers

an administratively-configured broadcast domain. The network administrator determines

Magnum 6K32F Series Fiber Switches offer high performance along with four

multiple useful features. The Magnum IEC61850 6K32F Series Switches are used in a

Series Switches enables them to inter-connect a series of subnets (one subnet per 6K32F

Switch port) in a LAN traffic center. The subnet connections may be via fiber or twisted

The mixed-media capability in the modular slot is ideal for upgrading existing

Ethernet LAN networks where existing cabling must be accommodated. The fiber-built-

performance in an Ethernet network center. A secure VLAN-enabled network is simply

R&D, and Marketing need to each keep a secure LAN, the 6K32F’s VLAN feature will

„ Supports PoE module to provide power via RJ-45 cable on the modular slots.

Series Managed switch is able to handle a VLAN application and provide security and

which ports and nodes are in which broadcast domains by setting membership profiles

capability is ideal for any application where a secure VLAN to multiple departments is

„ MDI-MDIX Auto-negotiating on RJ-45 ports for convenient cascading using

that require Gigabit backbone services. The performance characteristic of the 6K32F

Equipped with lots of advanced management features, the Magnum 6K32F

for each of them. The Magnum 6K32F’s VLAN capability can be configured in two

In an office environment where departments such as Finance, Engineering,

information controlled. The Managed Magnum 6K32F Series equipped with VLAN

Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08)

in media capability provides future-proof fiber cabling for the LAN structure. The

secured management features offer a multiple options to provide a secure Network

prevent traffic cross-over among traffic domains and thus keep sensitive data and

modular slot options to fulfill the choice of copper/Fiber, 10,100 or 1000Mb

pair cabling, 100Mbps or 10 Mbps speed, and full-or half-duplex mode.

Example 1Magnum 6K32F Series Switch for a VLAN application

types of virtual LANs; Port-based VLANs and Tag-based VLANs.

client for IP configuring, Radius X, TACACS+ etc.

straight RJ-45 cable.

2.4 Applications

solution.

needed.

Page 28 of the GarrettCom Managed Ethernet Switch (6K32FR) user manual — 2.4 Applications
Page 28 · click to enlarge
Page 28

from earthquake or fire hazards can be connected to one or two full duplex Gigabit Fiber

capability of the Magnum 6K32F Series Switch helps create a database of all the network

Full-duplex future proof fiber media can easily connect long distance subnets

ports are required for multiple subnets inside the building. The entire spread network is

The modularity of the 6K32F Series Managed Switch makes it an attractive

choice for use in applications with LAN connections to an organization’s multiple site

supported by the Magnum 6K32F Switch. A main NT-server in a secure area protected

subnets to easily manage the network. Secure web-based management is also included,

mining server for the vital database located in a separate secured building. The copper

In another Telecommunications storage data application, a secure managed

GarrettCom Managed Ethernet Switch (6K32FR) — 2.4 Applications diagram (page 28)
Fig. 14 · 2.4 Applications

1000Mbps full-duplex future-proof fiber media to provide secure long distance LAN

connections. The entire network is sharing a higher bandwidth Gigabit-enabled data-

Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08)

multiple subnets. The backbone consists of high speed LAN segments supported by

offices. The different offices can be easily connected together with the Fiber ports

switch is required to provide an Ethernet backbone for a diversified network with

and provide a stable secure network to all applications. The SNMP management

with authentication and encryption to keep out even determined trouble-makers.

Example 2.

ports.

Page 29 of the GarrettCom Managed Ethernet Switch (6K32FR) user manual — Example 3 Redundant Application
Page 29 · click to enlarge
Page 29

Magnum 6K32F’s equipped with redundant LAN features like S-Ring, RSTP, Link-Loss-

to connect into a Gigabit mesh structure with an RSTP and S-Ring combination used in a

solution to the requirements. The user-configurable Magnum 6K32F Series provides an

extra boost to the network requirements by providing copper/fiber media along with the

DC

The Magnum 6K32F Series with two Gigabit ports in a modular slot allows it

industry standard Rapid Spanning Tree Protocol 802.1d is used in the top eight switches

(see diagram below) to perform GB mesh fault recovery, whereas the bottom ring setup

has been .

managed to provide easy, detectable, uninterrupted support through a viewable SNMP

management flexibility allows the user more than one configuration alternative. The u

no-single-point-of-failure self-healing LAN topology along with a ring of multiple 6K

configured with S-Ring and Link-Loss-Learn for faster recovery in a big ring

A redundant LAN setup not only provides a reliable recovery solution from

higher bandwidth support of 10/100 and 1000Mb. The user can utilize the SNMP feat

other security features to provide a

has an advantage by fulfilling the present requirements as well as benefiting from the

Learn and various security features are easily qualified for the application. The -48V

at the edge to allow the system to efficiently recover from a fault in the network. The

money and recover valuable time. In a critical application where secure data has been

data mining storage facility, a redundant network provides a more secure

d over the gigabit mesh

Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08)

The 6K32F Series Managed Switch with NEBS Level 3 compliance and

multiple choices of modules to support future expansion as the network evolves. Th

the bandwidth for high speed to

mountable managed switch with over 24 ports is required with dense port features,

input power option with Dual Source is especially useful in telecom central offices.

network faults, but also improves operating up-time to simplify maintenance, save

The Magnum 6K32F Series Managed Switch equipped with copper and

optional Gigabit fiber ports on modular slots provide an economical and seamless

In a redundant application for high network availability where a rack-

The figure below has Magnum 6K32F’s and 6K25’s connecte

structure for a high bandwidth secure redundant LAN setup.

dual Gigabit port option in the modular slot boosts

equipped with VLAN, Port security, 802.1X, and

upport the peak traffic and minimize congestion.

secure and stable network as per the requirement

Example 3 Redundant Application

solution.

onitor.

Show 7 more labels / short text on this page
ure · ser · 25s · e · stored in a · m · s
Page 30 of the GarrettCom Managed Ethernet Switch (6K32FR) user manual — 2.4 Applications
Page 30 · click to enlarge
Page 30
GarrettCom Managed Ethernet Switch (6K32FR) — 2.4 Applications diagram (page 30)
Fig. 15 · 2.4 Applications

In a “ (video+data)” application where a network being designed to catered the

connected to the 6K32F Series. The robust Tag based vlan feature will able to segregates

AC/DC option will be an additional feature to take care of temperature and power option

need of multicast streaming and broadcast traffic of higher bandwidth to provide a video

The Dual Giga option on each of the two slot add 4 Gigabit ports to handle the

bandwidth requirement and 16 10/100 RJ-45 ports to feed the other needs of equipment

different ports belong to one group and provide an effective solution for bandwidth. The

SNMP option and secure web based will allow the remote capability and monitoring the

The Magnum 6K32F Series with two slots filled with Gigabit modules and a

network securely. The versatile mechanical design with rack mounting capability and

robust management firmware with MNS-6K qualify this requirement efficiently. The

Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08)

New IGMP L2-Mode feature on Magnum 6K32F’s and loaded with management

capability and secure web feature fulfill this requirement effectively.

6K32F Series in a Redundant application Example 4:

conferencing and video in demand channel option to the user.

issue.

Page 31 of the GarrettCom Managed Ethernet Switch (6K32FR) user manual — Figure 4: A multicast traffic through a 6K32F Series Switches using IGMP-
Page 31 · click to enlarge
Page 31
GarrettCom Managed Ethernet Switch (6K32FR) — 2.4 Applications diagram (page 31)
Fig. 16 · 2.4 Applications

Figure 4: A multicast traffic through a 6K32F Series Switches using IGMP-

Series to meet the fastest growing application of video monitoring or video surveillance

Equipped with IGMP-L2 mode enhanced features allow the Magnum 6K32F

Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08)

demand of industry and provide an economical and effective solution to meet that

L2 mode feature with Gigabit redundancy

expectation.

Page 32 of the GarrettCom Managed Ethernet Switch (6K32FR) user manual — 3.0 Installation
Page 32 · click to enlarge
Page 32

1.) If the equipment is mounted in an enclosed or multiple rack assembly, the environmental temperature around the equipment

2.) If the equipment is mounted in an enclosed or multiple rack assembly, adequate airflow must be maintained for proper and

3.) If the equipment is mounted in an enclosed or multiple rack system, placement of the equipment must not load unevenly or

4.) If the equipment is mounted in an enclosed or multiple rack assembly, verify the equipment’s power requirements to prevent

of network devices need to be connected in order to communicate with each other. These

compact size allows it to be easily placed in an office or lab area, and it can also be either

Magnum 6K32F site. The rugged metal case of the Magnum 6K32F Series will normally

5.) If the equipment is mounted in an enclosed or multiple rack assembly verify that the equipment has a reliable and

The location of a Magnum 6K32F Switch is dependent on the physical layout

of the network. Typically the Switch is placed in a central wiring location where groups

because they have rubber feet they can also be installed on a shelf or table top unit. The

protect it from accidental damage in a lab or workplace setting. Maintain an open view

that cooling can occur from the small fans (6K32F / FR) on the left side while the unit is

This section describes installation of the Magnum 6K32F Series Switches, as

of the front to visually monitor the status LEDs. Keep an open area around the unit so

Before installing the equipment, it is necessary to take the

must be less than or equal to 60C for 6K32F Series Switches.

6.) 24vdc, -48vdc, and 125vdc must be installed in restricted access locations.

7.) CB-Circuit breaker of 10Amps should shown on top of Rack.

Switches are typically rack mounted in a wiring closet see Section 3.3.2 below), but

Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08)

Locate an AC receptacle that is within six feet (2 meters) of the intended

overloading of the building/s electrical circuits.

3.1 Locating Magnum 6K32F Series Switches

well as connection of the various Ethernet media types.

shelf of wall-mounted (see Section 3.3.1 below).

uncompromised earthing path.

overload the rack system.

following precautions:

3.0 Installation

safe operation.

in operation.

Page 33 of the GarrettCom Managed Ethernet Switch (6K32FR) user manual — 10BASE-T
Page 33 · click to enlarge
Page 33

individually selected and configured per-port. See Section 2.4 for a description

2. Wipe clean the ends of the dual connectors with a soft cloth or lint-free lens tissue

support all standard Ethernet media types within a single Switch unit. This is

100BASE-FX Multi-mode 2.0km (6,562 ft) 6KP6-RJMSC, -RJMST

connectors. This procedure applies to ports using a 6K32F Series module, MST-

1. Before connecting the fiber optic cable, remove the protective dust caps from the

dampened in alcohol. Make certain the connectors are clean before connecting.

The following procedure applies to installations using a PM with ST-type fiber

3. Connect the Transmit (TX) port (light colored post) on the Magnum PM to the

Receive (RX) port of the remote device. Begin with the color-coded strand of

The Magnum 6K32F Series Switches are specifically designed to

The various media types supported along with the corresponding IEEE

small form factor Multi-mode 2.0km (6,562 ft) 6KP8-MTRJ, -MLC

Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08)

Single-mode 18.0km (95K ft) -RJSSC, -RJSSCL

accomplished by using a family of different port Modules which can be

bands at regular intervals; you must use the color-coded strand on the

IEEE Standard Media Type Max. Distance Port Module

1000BASE-FX Multi-mode 220m ( ft) GBIC-SXSC

small form factor Single-mode 15 km 6KP8- SLC

100BASE-TX twisted pair 100m (328 ft) 6KP8-RJ45

1000BASE-TX twisted pair 100m (328 ft) GBIC-TP

802.3 and 802.3u standards and connector types are as follows:

3.2.1 Connecting Fiber Optic ST-type, “twist-lock”

associated ports at each end of the fiber optic segment.

the cable for this first TX-to-RX connection.

3.2 Connecting Ethernet Media

Fiber:

of the PMs.

type port.

Copper:

10BASE-T

Single-mode 70km GBIC-ZXSC

Page 34 of the GarrettCom Managed Ethernet Switch (6K32FR) user manual — 3.2.3 Connecting Single-Mode Fiber Optic
Page 34 · click to enlarge
Page 34

The following procedure applies to installations using a PM with SC-type fiber

(9/125 microns for single-mode, 50/125 or 62.5/125 microns for multi-mode where xx/xx

fiber allows full bandwidth at longer distances, and may be used to connect 10 Mb nodes

following two media types100BASE-TX and 10BASE-T. CAT 5 cables should be used

mixed-speed network, since dual-speed ports are auto-sensing for either 10 and

1. Using standard twisted pair media, insert either end of the cable with an RJ-45 plug into the RJ-45 connector of the port. Note that, even though the connector is
5. The LINK LED on the front of the PM will illuminate when a proper connection

has been established at both ends (and when power is ON in the unit). If LINK is

not lit after the cable is connected, the normal cause is improper cable polarity.

connectors. Single-mode fiber cable has a smaller diameter than multi-mode fiber cable

when making 100BASE-TX connections. When the ports are used as 10BASE-T ports,

The following procedure describes how to connect a 10BASE-T or 100BASE-

are the diameters of the core and the core plus the cladding respectively). Single-mode

CAT 3 may be used. In either case, the maximum distance for unshielded twisted pair

Twisted Pair (CAT 3, 4, 5) 10BASE-T RJ-45

TX twisted pair segment to the RJ-45 port. The procedure is the same for both

4. Connect the Receive (RX) port (dark colored post on the PM) to the Transmit

(TX) port of the remote device. Use the non-color coded fiber strand for this.

When using single-mode fiber cable, be sure to use single-mode fiber port

Magn m 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08) u

3.2.4 Connecting Twisted Pair (RJ-45,CAT3, CAT5, Unshielded or

Twisted Pair (CAT 5) 100BASE-TX RJ-45

and 100Mb) be used whenever possible in order to provide flexibility in a

Swap the fiber cables at the PM connector to try to remedy this situation.

When connecting fiber media to SC connectors, simply snap the two square male

connectors into the SC female jacks of the 6KPM until they click and are secure.

The RJ-45 ports of the Magnum 6K32F Series can be connected to the

The same procedure for multi-mode fiber applies to single-mode fiber

Media IEEE Standard Connector

3.2.2 Connecting Fiber Optic SC-type, "Snap-In"

connectors, i.e., using 6K-MSC or 6K-SSC (single mode) etc.

connectors. Follow the steps listed in Section 3.2.2 above.

3.2.3 Connecting Single-Mode Fiber Optic

unshielded and shielded twisted pair cables.

up to 10 Km apart, or 18Km with the 6K-SSC.

cabling is 100 meters (328 ft).

100Mb/s.

Shielded)

Page 35 of the GarrettCom Managed Ethernet Switch (6K32FR) user manual — 3.2.5 Connecting Twisted Pair (CAT-5e or better, Unshielded or
Page 35 · click to enlarge
Page 35
2. Connect the other end of the cable to the corresponding device 3. Use the LINK LED to ensure proper connectivity by noting that the LED will be illuminated when the unit is powered and proper connection is

could produce high (greater than 2500V ) levels of ground potential rise (GPR)

during line-to-ground fault conditions. The 6K32 passes the 1613specifications

CAT-5e, or for better results, 100-ohm UTP shielded twisted pair (STP) balanced cable.

Mb and 1000Mb) be used whenever possible in order to provide flexibility in a

1. 1000BASE-T connections require that all four pairs or wires be connected. Insert either end of the cable with an RJ-45 plug into the RJ-45 connector of the port.

for zero packet loss with fiber ports & with RJ45 ports used as indicated here.

The RJ-45 1000BASE-TX Gigabit ports of the Magnum 6K32F Series can be

connected via copper media with the following minimum specifications; 1000BASE-T,

The following procedure describes how to connect a 1000BASE-T twisted pair segment

2. Connect the other end of the cable to the corresponding device 3. Use the LINK LED to ensure proper connectivity by noting that the LED will be illuminated when the unit is powered and proper connection is established.

telecommunication multiplexers installed in close proximity (i.e., less than 2

The CAT-5e or the more effective 100-ohm UTP shielded twisted pair (STP) balanced

to the RJ-45 port. The procedure is the same for both unshielded and shielded twisted

substation applications to interface to field devices across distances which

cable is recommended when making 1000BASE-TX connections. In either case, the

Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08)

advises that, for substation applications, the RJ-45 ports are intended for

meters or 6.5ft) to the 6K32. It is not recommended to use these ports in

3.2.5 Connecting Twisted Pair (CAT-5e or better, Unshielded or

Media IEEE Standard Connector

shielded, either unshielded or shielded cables and wiring may be used.

maximum distance for unshielded twisted pair cabling is 100 meters (328 ft).

connectivity to other communication equipment such as routers or

Twisted Pair (CAT-5e) 1000BASE-T RJ-45

cables and wiring may be used.

mixed-speed network.

pair cables.

Shielded) · established

Page 36 of the GarrettCom Managed Ethernet Switch (6K32FR) user manual — TX RX
Page 36 · click to enlarge
Page 36

communications for both telecommunication and data communications applications. Due

for various applications. The small-chassis Magnum 6K is designed for industry-standard

transceiver for any reason. Not removing the fiber cable first can damage the fiber cable,

handling the SFP transceivers since the

3.2.6 Gigabit SFP (Small Form-factor Pluggable) Optical Transceivers

to its compact, hot pluggable characteristics, SFPs are becoming a very popular choice

higher cabling. The maximum length supported on copper 1000BASE-T is 100mts (328

The small form-factor pluggable (SFP) is a compact optical transceiver used in optical

All SFPs used in Magnum 6Ks are compliant with the industry standard Multi-Source

other device, it is recommended to use Crossover RJ-45 (4-twisted pair) category 5 or

Gb-SFPs and Gb-SFPCU (copper) for user selection of the SFP gigabit media type as

recommended to use a straight-through RJ-45(4-twisted pair) connection while

connecting to any Server/workstation. While connecting with any Switch/repeater or

Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08)

GarrettCom Managed Ethernet Switch (6K32FR) — 3.2.6 Gigabit SFP (Small Form-factor Pluggable) Optical Transceivers diagram (page 36)
Fig. 17 · 3.2.6 Gigabit SFP (Small Form-factor Pluggable) Opti…

advised not to remove and insert a SFP

Agreement (MSA) ensuring compatibility with a wide range of networking kit.

TX RX

TX RX

Side View ---Duplex LC connector -- Front view

sceiver frequently as this may shorten its useful life.

SFP modules are static sensitive devices.

cable connector or optical interfaces. It is

GarrettCom Managed Ethernet Switch (6K32FR) — TX RX diagram (page 36)
Fig. 18

desired.

ft.).

Show 4 more labels / short text on this page
is · Bail clasp · Bail clasp · tran
Page 37 of the GarrettCom Managed Ethernet Switch (6K32FR) user manual — PM’s with Fiber Media
Page 37 · click to enlarge
Page 37

and the “Cable Loss” for 9/125 (Single-mode) is 0.4 dB/km (LXSC25)

Receiver Sensitivity and Transmitter Power are the parameters necessary to

3.2.7 Power Budget Calculations for Magnum 6K32F Series

Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08)

compute the power budget. To calculate the power budget of different fiber media

where the “Cable Loss” for 62.5/125 and 50/125μm (M.m) is 2.8 dB/km,

where PT = Transmitter Output Power, and PR = Receiver Sensitivity

installations using Magnum products, the following equations should be used:

Worst case distance = {Worst case OPB, in dB} / [Cable Loss, in dB/Km]

The various SFPs transceivers supported by GarrettCom 6KQs D slot are-

6KP2-2GSFP 2 SFP

1 CU

6KP1-1SFP 1SFP

6KP1-1GCU 1 CU

Gb SFP fiber optic transceivers

Gb SX, 850nm wavelength, 500 m distance SFP-SX

SFP-LX10 Gb LX, 1310nm wavelength, 10km dist

SFP-ZX70

Worst case OPB = OPB - 1dB(for LED aging) - 1dB(for insertion loss)

and the “Cable Loss” for 100/140 (Multi-mode) is 3.3 dB/km,

SFP-ZX40 Gb ZX, 1550nm wavelength, 40km distance

Gb ZX, 1550nm wavelength, 70km distance

and the “Cable Loss” for 9/125 (Single-mode) is 0.5 dB/km

SFP-LX25 Gb LX, 1310nm wavelength, 25km

Gb Modules, fixed ports--SFP (Small Form Factor)

OPB (Optical Power Budget) = PT(min) - PR(min)

PM’s with Fiber Media

6KP2-1GSFP1CU 1SFP

distance · Module Model# Gigabit

Page 38 of the GarrettCom Managed Ethernet Switch (6K32FR) user manual — LXSC25
Page 38 · click to enlarge
Page 38
GarrettCom Managed Ethernet Switch (6K32FR) — 3.2.7 Power Budget Calculations for Magnum 6K32F Series PM’s with Fiber Media diagram (page 38)
Fig. 19 · 3.2.7 Power Budget Calculations for Magnum 6K32F Ser…

and the “Cable Loss” for 9/125 (Single-mode) is 0.25 dB/km(LXSC40)

and the “Cable Loss” for 9/125 (Single-mode) is 0.2 dB/km (LXSC70)

Lucent’) web sites and catalogs to provide guidance to network designers and installers.

mode 18+ (0.4) 1300 9/125 -15 -31 14 28 17.5 35

mode 40 (0.4) 1300 9/125 -5 -34 29 58 32.5 65

mode 2 (0.4) 1300 62.5/125 -19 -31 12 4 16 5.7

1000Mb Multi- mode 0.55 850 62.5/125 50/125 -9.5 -17 5.5 2 12.5 4

1000Mb Single- mode 10 1300 9/125 -9.5 -20 8.5 17 10.5 21

1000Mb Single- mode 25 1550 9/125 -4.0 -21 15 37.5 17.5 43

1000Mb Single- mode 40 1550 9/125 -4.0 -21 15 60 17.5 70

1000Mb Single- mode 70 1550 9/125 -3.0 -23 18 90 20.5 102

* Note: The use of either multi-mode or single-mode fiber to operate at 100Mbps speed over long distances (i.e., in excess of approx. 400 meters) can be achieved only

  • The worst-case OPB of the fiber link must be greater than the fiber cable’s

The following data has been collected from component manufacturer’s (Agilent’s and

Mode 15+ (0.4) 1310 9/125 -15 -28 11 22 - -

  • The 100Mb fiber segment must operate in full-duplex (FDX) mode, i.e. the

full-duplex (factory default) setting for 100Mbps fiber ports must be used.

(Attenuation = Cable loss + LED aging loss + Insertion loss + safety factor)

Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08)

if the following factors are both applied:

passive Attenuation.

LXSC25

ZXSC40

ZXSC70

GBIC-

GBIC-

GBIC-

Page 39 of the GarrettCom Managed Ethernet Switch (6K32FR) user manual — 3.3 Table-Top or Shelf Mounting
Page 39 · click to enlarge
Page 39

Rack-mount installation requires special 19” rack-mounted brackets and screws (included

standard for Central Office rack-mounting purposes. The 23” and the ETSI brackets are

permits it to be mounted in various ways. The same holes fit all three types (19”, ETSI,

and 23”) of brackets. The mounting for the 23” is illustrated in Figure 3.3.1 below. The

3.3.1 Rack-mounting (for 19” RETMA racks) Magnum 6K32F & 6K32FC Installation of a Magnum 6K32F & 6K32FC Fiber Switch in a 19” rack is a

with each Magnum 6K32F & 6K32FC unit). These brackets attach to the front sides of

(0.875”) air

and below.

The Magnum 6K32F Series Managed Switches can be easily mounted on a

21”) brackets are also available (optional) for rack-mounting the Magnum 6K32F &

6K32FC Switches. These brackets are popular in the Telco industry where they are a

These brackets are rack-mounted in a frame typically accessed in operation

The bracket mounting holes in the sides of the Magnum 6K32F & 6K32FC

brackets may be attached flush with the front, or attached in the center for a set-back

Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08)

table-top or any suitable horizontal surface. They have four rubber feet to provide

simple procedure. The units are 1U (1.70”) high. When properly installed, the front-

mounted LED status indicators should be in plain view and easy to read.

GarrettCom Managed Ethernet Switch (6K32FR) — 3.3 Table-Top or Shelf Mounting diagram (page 39)
Fig. 20 · 3.3 Table-Top or Shelf Mounting

the Switch (regular package, not the Reverse version), which is then

The 23” brackets and the ETSI (European metric, approx.

typically fastened into a standard 19” RETMA rack as shown here.

stability without scratching finished surfaces.

3.3 Table-Top or Shelf Mounting

mounting which may reduce cabling torque.

Fig 3.3.1 Dual Side

mainly used for larger equipment.

from both sides.

Show 12 more labels / short text on this page
6K32FC switch with · space above · convection · a minimum · adequate · cooling, · always · install a · of 1/2U · For · Mountings for · 6K32F Series
Page 40 of the GarrettCom Managed Ethernet Switch (6K32FR) user manual — Fig 3.3.2 Reverse Magnum 6K32F Series
Page 40 · click to enlarge
Page 40

The optional 23” brackets and the ETSI (21”) brackets each come as a pair in a

(Ethernet cabling, power cabling and console port cabling) connectors in the rear, and the

frame, 23” frame, or ETSI (21”) frame. The 19” brackets are included with each unit, the

With each bracket type, there are three different mounting options as shown in Fig. 3.3.2.

supply and have a recessed male IEC connector for the AC power cord at the left-rear. A

AC voltage is from 90 to 260 volts with a power input frequency between 47 and 63 Hz.

present, and a second or dual set of LEDs are used for status visibility in the front of the

The case of the Magnum 6K32F has mounting holes prepared for each of the mounting

(0.875”) air

and below.

The Magnum 6K32F Series Switches incorporate an internal universal power

package, along with the necessary screws for attaching the brackets to the sides of the

manual power ON-OFF switch is adjacent. A six-foot 115 VAC 60 Hz standard power

The auto-ranging power supply supports installation environments where the

6K32FRC The optional Reverse Magnum 6K32FR/FRC Model has all of the cabling

status LEDs in the front. The status LEDs that are co-incident with the ports are still

Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08)

There are three options of brackets available to mount in the standard 19”

3.3.2 Rack-mounting, Reverse version of the Magnum 6K32FR &

cord is supplied with each unit shipped within the United States and Canada.

3.4 Powering the Magnum 6K32F Series Managed Switch

GarrettCom Managed Ethernet Switch (6K32FR) — 3.3.2 Rack-mounting, Reverse version of the Magnum 6K32FR & diagram (page 40)
Fig. 21 · 3.3.2 Rack-mounting, Reverse version of the Magnum 6…

Magnum Switch unit. They must be ordered as separate line items.

arrangements. Users may choose the mounting arrangement most

other two may be purchased as separate options.

Fig 3.3.2 Reverse Magnum 6K32F Series

unit, showing the same data.

suitable for their installation.

Show 10 more labels / short text on this page
6K32FRC switch with · a minimum · space above · convection · adequate · cooling, · always · install a · of 1/2U · For
Page 41 of the GarrettCom Managed Ethernet Switch (6K32FR) user manual — 3.4.1 Alarm Contacts for monitoring internal power, and Software Traps
Page 41 · click to enlarge
Page 41

connected or disconnected without concern for AC power-related problems or damage to

Power supply options are available to suit the 6K32F Series Switches to special

3.4.1 Alarm Contacts for monitoring internal power, and Software Traps The Alarm Contacts feature, optional on Magnum 6K32F Series, provides

enabled, the Form C Normally Closed (NC) contact is held close during normal software

The second (bottom position) NC Alarm Contact is held close when there is

5. The software operation needs to be enabled and set to get the Alarm traps. For detailed

information about the Software Alarm and software control of SNMP alarm traps, please

The 32-port units will consume over 30 watts of power typically. When connecting the

high-availability communications and/or heavy industrial-grade applications, including:

6K32F case. The AC or DC power input connection is in the same panel. A manual On-

The first NC Alarm Contact (top position) is a “Software Alarm”, operated

feature with a software configuration command if desired. When the Software Alarm is

Ethernet cabling, there is no need to power down the unit. Individual segments can be

See the Appendices of this manual for more details. Use an RFQ for other variations.

Off Switch for power to the unit is not available on 6K32F Series units with the Alarm

because the NC contacts will open when internal power is lost, either from an external

two Form C Normally Closed (NC) contacts to which the user can attach two sets of

status monitoring wires at the green terminal block. When this option is present, the

operation. A user-defined software malfunction, such as an SNMP Trap, a Software

1. There are four terminal blocks (1,2,3,4)provided next to the AC/DC power supply

Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08)

terminal block for Alarm Contacts is part of the Power Input panel in the Magnum

by user settings in the MNS-6K software. The user can disable the Software Alarm

Security violation or an S-Ring Fault, causes the contact to open and thus trigger an

power on the main board inside of the 6K32F. This provides a “Hardware Alarm”

power down condition or by the failure of the power supply inside of the Magnum

Contacts option, as these two features occupy the same space in the case.

reference the Magnum MNS-6K Software User Manual. (Chapter 19).

* -48VDC, 24VDC and 125VDC with dual-source DC input,

* -48VDC, 24VDC and 125VDC with single DC input,

6K32F Series Switch. Useful info. about Alarm contacts:

3. The bottom two pins (3,4) are hardware operated
2. The top two pins (1,2) are software operated
4. By default it is NC (normally closed)

alarm in the user’s monitoring system

the unit.

Page 42 of the GarrettCom Managed Ethernet Switch (6K32FR) user manual — STOP!!!
Page 42 · click to enlarge
Page 42

customers required 6KPM modules installed. There may be situations where 6KPM cards

Front panel face plate package. The Front panel faceplate package includes the

intended for temporary connectivity to other equipment such as PCs. Since the

need to be added or replaced. In cases where a 6KPM module needs to be added in the

offs for the Granddaughter board, seven #4-40 Pan-Head screws along with a

mixed with other Fiber combo 6KPM card packages. Always install the PM

3.5 6K32F Series Port Module (6KPM) Installation The Magnum 6K32F Series Switches are received from the factory with the

modular slots, the faceplate for an available front-mounted slot must be removed. The

electronic equipment) are sensitive to static discharge. Use proper ESD

1. Make sure the 6KPM Card package has all necessary accessories to install it

(Daughterboard (Bigger) and Granddaughter board (smaller), three 5/8 stand

Granddaughter board. The copper 6KPM card should not work properly if

console port connection is temporary, it is excluded from IEEE 1613 packet-

advises that, for substation applications, the serial RJ-45console ports are

Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08)

performed by trained service persons. The port modules (like most

properly. Each 6KPM Card package for field installation contains

Failure to do so may result in damage to the unit

from the chassis before attempting to remove

3.5.1 Preparation for Installing and Removing 6KPMs

for all powers single or dual, is unplugged

loss testing per the 1613 standard-defined test procedure.

Be sure the power cord and connections

and/or replace any PM cards.

module separately one by one to avoid the mixing.

and will void the warranty.

front panel and four #4-40 Flat-Head screws.

STOP!!!

measures when handling port modules.

following procedure describes this operation.

Page 43 of the GarrettCom Managed Ethernet Switch (6K32FR) user manual — 3.5 6K32F Series Port Module (6KPM) Installation
Page 43 · click to enlarge
Page 43

The Magnum 6K32F chassis are combined with top, bottom and module panel

Remove the side panel (2 screws located on the right side of chassis). Second,

remove the module panel screws (total 16) as shown in the fig 3.5.1a. Third,

cover can be easily pulled off to the front from the chassis base, as shown in

the Fig. 3.4.1b. When the chassis top cover has been removed, the interior of

parts and assembled together with the help of 34 Philips-head screws. First

remove the top cover screws (16 screws). Once these are removed, the top

Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08)

Figure 3.5.1aRemoving module panels after the screws being removed
GarrettCom Managed Ethernet Switch (6K32FR) — 3.5 6K32F Series Port Module (6KPM) Installation diagram (page 43)
Fig. 22 · 3.5 6K32F Series Port Module (6KPM) Installation
GarrettCom Managed Ethernet Switch (6K32FR) — 3.5 6K32F Series Port Module (6KPM) Installation diagram (page 43)
Fig. 23 · 3.5 6K32F Series Port Module (6KPM) Installation
Fig 3.5.1bPulling out the top cover from the chassis base
2. Remove Chassis Cover

the unit is exposed.

Page 44 of the GarrettCom Managed Ethernet Switch (6K32FR) user manual — 3.5.2 Installing 6KPM Cards in the Magnum 6K32F Series
Page 44 · click to enlarge
Page 44

Up to four front-mounted 6KPM cards may be installed in one Magnum 6K32F

Looking down into the Magnum 6K32F Series unit, notice that there are individual PM

installation spaces and female latch (white) connectors provided on the far right side of

the main board along with four stand-off’s for 6KPM card position. (See Figure 3.5.1c).

Figure 3.5.1cMagnum 6K32F Series modular slot side (front-right side), without

Granddaughter board. The 5/8 stand offs are used to place the daughter board

Fig 3.5.2aGranddaughter Board placed in modular slot and secured with three
2. Placed Granddaughter board (as shown in fig. 3.5.2a) on the chassis built in

stand off (female) provided at the front of the 6K32F Main Board and screw

Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08)

Series Managed Switch unit. Follow these steps to install a 6KPM.

1. Remove top chassis cover. See procedure in Section 3.5.1 above.

3.5.2 Installing 6KPM Cards in the Magnum 6K32F Series

down tightly with the three 5/8 stand-off (male) on the top of the

GarrettCom Managed Ethernet Switch (6K32FR) — 3.5.2 Installing 6KPM Cards in the Magnum 6K32F Series diagram (page 44)
Fig. 24 · 3.5.2 Installing 6KPM Cards in the Magnum 6K32F Seri…
GarrettCom Managed Ethernet Switch (6K32FR) — 3.5.2 Installing 6KPM Cards in the Magnum 6K32F Series diagram (page 44)
Fig. 25 · 3.5.2 Installing 6KPM Cards in the Magnum 6K32F Seri…

on the top of the granddaughter board and latch it securely.

5/8” stand-offs as shown with arrow mark

chassis cover

Page 45 of the GarrettCom Managed Ethernet Switch (6K32FR) user manual — 6K32F
Page 45 · click to enlarge
Page 45

placed on the Granddaughter and main board.

aligned with stand offs then press slowly and firmly with two fingers (as shown

Once the latching connectors are aligned properly and the mounting holes are

n Fig. 3.5.2d) on the top of the latching connectors until the connectors

GarrettCom Managed Ethernet Switch (6K32FR) — 3.5.2 Installing 6KPM Cards in the Magnum 6K32F Series diagram (page 45)
Fig. 26 · 3.5.2 Installing 6KPM Cards in the Magnum 6K32F Seri…
3. The figure here illustrates the basic layout of an individual PM card. 6KPM

Hold the daughter board with both hands at the end and align the two cream

color latching connectors (male) placed at the bottom of the daughter board

F d shown upside down with two male latch connectors

Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08)

card fits into the space provided on the main board over the grand-daughter Bd. a

Fig 3.5.2c Bd. and the

( as shown in below fig. with arrow mark). male latched cream color connectors

GarrettCom Managed Ethernet Switch (6K32FR) — 3.5.2 Installing 6KPM Cards in the Magnum 6K32F Series diagram (page 45)
Fig. 27 · 3.5.2 Installing 6KPM Cards in the Magnum 6K32F Seri…
GarrettCom Managed Ethernet Switch (6K32FR) — 3.5.2 Installing 6KPM Cards in the Magnum 6K32F Series diagram (page 45)
Fig. 28 · 3.5.2 Installing 6KPM Cards in the Magnum 6K32F Seri…

Daughter Bd. Being placed over the Granddaughter

mating connector being matched to lockup properly

with the other female connectors

As shown below in Fig. 3.5.2c

ig 3.5.2bDaughter Boar

latching up 6KPM Card

6K32F

Fig.3.5.2dSecurely

latch.

Step 5.

Step 4.

Show 5 more labels / short text on this page
nd the · s · below i · into a Magnum · Series chassis
Page 46 of the GarrettCom Managed Ethernet Switch (6K32FR) user manual — 3.5.3 Removing 6KPM Cards
Page 46 · click to enlarge
Page 46
6. Now screw down the daughter board with 7 #4-40 screws, except the last two at

the end, so that it holds the daughter board securely. The figure below shows the

plates(included with the 6K-modules) need to be properly placed on the front of

To properly remove a 6KPM card from the 6K32F Managed Switch, follow the

BLNK) to cover the slot opening in the front panel. This will maintain proper cooling

top view of 6KPM card after successfully installing the 6KPM cards inside the

7. Once the 6KPM cards have been installed, the chassis top cover can be placed

the rear end and fits properly to match the holes. Make sure the chassis cover is

aligned properly before securing the enclosure. Secure the cover with 18 #4-40

by matching up the two front corners properly and sliding it in until it reaches

Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08)

Fig. 3.5.2e Top View6KPM Module installed inside a 6K32F Series Switch
GarrettCom Managed Ethernet Switch (6K32FR) — 3.5.3 Removing 6KPM Cards diagram (page 46)
Fig. 29 · 3.5.3 Removing 6KPM Cards

air flow, safety, and operation as required by FCC, CE, and other regulations.

8. Once the installation of cover is done properly, the front panel screen
1. Remove chassis cover See procedures in Section 3.5.1 above.

the chassis cover to complete the installation process.

3.5.3 Removing 6KPM Cards

Magnum 6K32F.

3 steps below.

screws.

Page 47 of the GarrettCom Managed Ethernet Switch (6K32FR) user manual — F
Page 47 · click to enlarge
Page 47

now empty slot is to remain unused, be sure to install a 6KM-BLNK face plate cover.

These screws are used to secure a 6KPM card in position (see Figure 3.5.3a). Remove the

Carefully and gently pull out the daughter board from the latching connectors, using both

and keep off from dust and other unavoidable substance, otherwise can cause a failure

On the top of the daughter module there are seven retaining screws for each 6KPM card.

2. If the PM module in the modular slot is not being installed properly or loose in connection, the MNS-6K management software will not boot-up properly and a error

will generate as –{ failed to read register device type (offset 0x1600) on slot “A or B or

GarrettCom Managed Ethernet Switch (6K32FR) — 3.5.3 Removing 6KPM Cards diagram (page 47)
Fig. 30 · 3.5.3 Removing 6KPM Cards

hands, gripping the board near the latch-up connectors as shown in Fig. 3.5.3b . If the

slot must be covered with Blank cover, to maintain proper air-inflow inside the unit

3. Always boot-up the Switch after any new module installation on modular slot to c

Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08)

GarrettCom Managed Ethernet Switch (6K32FR) — 3.5.3 Removing 6KPM Cards diagram (page 47)
Fig. 31 · 3.5.3 Removing 6KPM Cards

onfirm the successful installation, before placing the chassis cover.

2. Remove retaining screws placed on top for the 6KPM
Figure 3.5.3bRemoving a 6KPM Card

ollow the step 8 to complete the process successfully.

C or D”}, whichever the slot has been used.

3. Remove 6KPM Card

Granddaughter board with the

Figure 3.5.3aTop View – 7

retaining screws shown by

three standoffs holding the

in the Switch.

chassis.

F

arrows

Page 48 of the GarrettCom Managed Ethernet Switch (6K32FR) user manual — Management) (
Page 48 · click to enlarge
Page 48
GarrettCom Managed Ethernet Switch (6K32FR) — 3.6 Connecting the Console Terminal to Magnum 6K32F Series (Management) diagram (page 48)
Fig. 32 · 3.6 Connecting the Console Terminal to Magnum 6K32F…

6K32F Series Switch configuration for Network Management, please refer to Magnum 6K Software Manual available on GarrettCom‘s FTP site. Detail info. about the MNS is available on 2.2.9 ( see page no. 19) of this manual.

The above provided information enables a managed station (a PC or Console terminal) to

Console Port (the RS-232 port on the 6K32F Switch) to the your PC, so that

3.6.1 RS-232 (DB-9) Console Com port (Serial port) pin assignments.

Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08)

3.6 Connecting the Console Terminal to Magnum 6K32F Series

Use a DB-9 “null modem” cable to connect the Magnum 6K32F Series

CD Carrier detect (not used)

TXD Transmit Data (output) 3

Pin Signal Description

RXD Receive Data (input) 2

GND Signal Ground 5

Rear View of Magnum 6K32F Series

your PC becomes the 6K32F’s Console Terminal.

GarrettCom Managed Ethernet Switch (6K32FR) — Rear View of Magnum 6K32F Series diagram (page 48)
Fig. 33 · Rear View of Magnum 6K32F Series

DB-9 (Console port connector)

open not used 4

6-9 open not used

Management) (

package.

Page 49 of the GarrettCom Managed Ethernet Switch (6K32FR) user manual — 3.6 Connecting the Console Terminal to Magnum 6K32F Series (Management)
Page 49 · click to enlarge
Page 49

intended for temporary connectivity to other equipment such as PCs. Since the

female to female cable is required to communicate properly. The Null-Modem (DB-9)

console port connection is temporary, it is excluded from IEEE 1613 packet-

advises that, for substation applications, the serial RJ-45console ports are

Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08)

er from the factory, along with the unit as- cable is optional and can be ord

loss testing per the 1613 standard-defined test procedure.

connect directly to the switch using a straight through cable.

CONSOLE CBL for serial port

CONSOLE USB for USB port

Page 50 of the GarrettCom Managed Ethernet Switch (6K32FR) user manual — 4.0 OPERATION
Page 50 · click to enlarge
Page 50

Each time a packet arrives on one of the switched ports, the decision is taken to

either filter or to forward the packet. Packets whose source and destination addresses are

on the same port segment will be filtered, constraining them to that one port and relieving

added, removed or moved from one segment to another, the 6K32F Switch automatically

speed among all of its ports. The Magnum 6K32F Series support 10/100Mbs for copper

media and 10 or 100Mb separate traffic domains for fiber ports to maximize bandwidth

Magnum 6K32F Series units are plug-and-play devices. There is no software

the rest of the network from having to process them. A packet whose destination address

is on another port segment will be forwarded to the appropriate port, and will not be sent

to the other ports where it is not needed. Traffic needed for maintaining the operation of

An address-aging algorithm causes least-used addresses to fall out in favor of

utilization and network performance. All ports can communicate to all other ports in a

Magnum 6K32F, but local traffic on a port will not consume any of the bandwidth on

configuring necessary to be done for basic operation at installation or for maintenance.

(resides inside the unit) on the 6KP8-RJ45 (modular port). Optional Half / Full duplex

mode and 10 or 100Mbps selection for the switched ports must be configured through

This chapter describes the functions and operation of the Magnum 6K32F

A Magnum 6K32F Series provides switched connectivity at Ethernet wire-

MNS-6K software per unit as per the requirement. The internal functions of both are

the network (such as occasional multi-cast packets) are being forwarded to all ports.

All Magnum 6K32F Series units have address table capacities of 4K node

addresses suitable for use in larger networks. They are self-learning, so as nodes are

Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08)

The only hardware configuration settings are user options for an UP-LINK Switch

switching mode, which eliminates bad packets and enables peak performance to be

frequently-used addresses. To reset the address buffer, cycle power down-and-up.

The Magnum 6K32F Series Switches operate in the store-and-forward

achieved when there is heavy traffic on the network.

4.1 Switching Functionality

keeps up with node locations.

4.0 OPERATION

Series Switch.

described below.

any other port.

Filtering and Forwarding · Address Learning

Page 51 of the GarrettCom Managed Ethernet Switch (6K32FR) user manual — 4.2 Status LEDs
Page 51 · click to enlarge
Page 51
F/HFull / Half duplex LED, ON when the port is running full duplex, OFF

4.3 Auto-Cross (MDIX)Auto-negotiation, for 10/100Mbps RJ-45 ports

unmanaged switches, legacy hubs, managed switches, media-converters etc. Please note

100Mb speed, and at either half- or full duplex mode depending on the capabilities of the

do not support auto-negotiation properly, and require that the switched port to which they

100/10: Speed LED, ON when the speed is 100Mbps , OFF when the speed is 10 Mbps

crossover cables are needed when connecting the 6K32F’s 10/100 copper ports to other

that there can be conditions with managed switches where the switch manager fixes the

managed switch by the manager commands. In such cases, the 10/100 speed or the F/H

mode may be affected, but auto-cross in the 6K32F Series Switches will still work. The

auto-cross function can be disabled, if fixed the port at 10 or 100Mb through software..

The Managed Magnum 6K32F Series Fast Ethernet copper ports can be set for

either fixed 100Mb speed or N-way auto-negotiation per the IEEE802.3u standard. The

6K-MNS Software for each RJ-45 port separately. For detail information see Section 9

used application for the Managed 6K32F Switch copper ports is to connect one of them

remote device. Standard commercially available Fast Ethernet media converters mostly

situation by configuring the ports as per desire through MNS software port settings and

negotiation. At 100Mb-fixed speed, the user may select half- or full-duplex mode by

are connected be at 100Mb fixed speed. Attachment to 10/100 auto-negotiation ports

The 32 RJ-45 ports on Magnum 6K32F Series support auto-cross (MDI or

(Port Setup) of Magnum 6K32F Software user guide (MNS-6K). One frequently-

using a fiber media converter to another Switch in the network backbone, or to some

typically will not work properly. The 6K32F Series Switch’s RJ-45 ports handle this

Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08)

LK: Steady ON, Link status for 10 Mbps and 100Mbps operation.

MDIX) in the auto-negotiation mode according to the IEEE 802.3u standard. No

port settings via software, and the result of the auto-negotiation is changed in the

other remote 100Mb device. In this case, it is desirable to operate the fiber link at

PWR: Power LED, ON when external power is applied to the unit.

ACT: ON with port activity for 10 Mbps and 100Mbps operation.

selection is made via 6K-MNS software. The factory default setting is for auto-

can check the port status of each port after the change.

For all Magnum 6K32F Series models :

for half duplex.

4.2 Status LEDs

Page 52 of the GarrettCom Managed Ethernet Switch (6K32FR) user manual — 4.4 Flow-control, IEEE 802.3x standard
Page 52 · click to enlarge
Page 52

and are connected to another auto-negotiating device, there are 4 different speed and F/H

may be limited within that collision domain. The Path Delay Value (PDV) bit-times must

Fast Ethernet switched ports operating at 100Mb half-duplex, the bit time delay is 50BT.

Full-Duplex mode. The purpose of flow-control is to reduce the risk of data loss if a long

attempting to transmit to one 100Mb port, and in other protracted heavy traffic situations.

When Magnum 6K32F Series RJ-45 copper ports are set for auto-negotiation

modes possible depending on what the other device supports. These are: (1) 100Mb full-

The auto-negotiation logic will attempt to operate in descending order and will normally

mode” result can change at any time depending on network changes that may occur). If

account for all devices and cable lengths within that domain. For Magnum 6K32F Series

burst of activity causes the switch to save frames until its buffer memory is full. This is

-- the devices at both ends of the cable are capable of operation at either 10

  • NOTE – Some NIC cards only auto-negotiate when the computer system

arrive at the highest order mode that both devices can support at that time. (Since auto-

the device at the other end is not an auto-negotiating device, the 6K32F’s RJ-45 ports

When operating in 100Mb half-duplex mode, cable distances and hop-counts

Magnum 6K32F Series Switches incorporate a flow-control mechanism for

Auto-negotiation per-port for 802.3u-compliant switches occurs when:

that they are in is powered up. These are exceptions to the “negotiate at

negotiation is potentially an externally controlled process, the original “highest order

will try to detect its idle signal to determine 10 or 100 speed, and will default to half-

most likely to occur when data is moving from a 100Mb port to a 10 Mb port and the

Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08)

Magnum 6K32F Series Switches implement the 802.3x flow control (non-

duplex, (2) 100Mb half-duplex, (3) 10 Mb full-duplex and (4) 10 Mb half-duplex.

-- the second of the two connected devices is powered up*, i.e., when

10Mb port is unable to keep up. It can also occur when multiple 100Mb ports are

LINK – enabled” rule above, but may be occasionally encountered.

-- the LINK is re-established on a port after being lost temporarily.

Mb or 100Mb speed and/or in full- or half-duplex mode, and can

send/receive auto-negotiation pulses, and . . .

4.4 Flow-control, IEEE 802.3x standard

LINK is established for a port, or

duplex at that speed per the IEEE standard.

General information -

Page 53 of the GarrettCom Managed Ethernet Switch (6K32FR) user manual — 5.2 6KPM Module Description
Page 53 · click to enlarge
Page 53

blocking) on Full-Duplex ports, which provides for a “PAUSE” packet to be transmitted

The transmitting device is commanded to stop transmitting into the 6K32F’s Switch port

algorithm on 10/100 Mb ports for flow control. That is, the switch prevents frames from

receiving. This temporary “collision” delay allows the available buffer space to improve

This section applies only to PMs shipped as separate items, i.e., 6K32F Series

occurred during shipment or delivery. Inspect the contents of this package for

Module for flexible mixed-media connectivity to RJ-45 and fiber media in the

to the sender when the packet buffer is nearly filled and there is danger of lost packets.

Remove the 6K32F Series PM(s) from the shipping container. Be sure to keep

the shipping container should you need to ship any of the PMs separately at a

for sufficient time to let the Switch reduce the buffer space used. When the available

transmitter to start sending the packets. Of course, the transmitting device must also

entering the device by forcing a collision indication on the half-duplex ports that are

installing a 6K32F Series PM; notify the carrier of any damage you believe

supplier. If you need to return the unit, use the original shipping container if

Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08)

any signs of damage and ensure that the items listed below are included.

An important feature of the Magnum 6K32F Series is the use of one Port

free-buffer queue increases, the Switch will send a “RESUME" packet to tell the

support the 802.3x flow control standard in order to communicate properly during

later date. In the event there are items missing or damaged, contact your

This chapter describes each Port Module (PM), including appearance,

Examine the shipping container for obvious damage prior to

5.0 Magnum 6K32F Series Managed Switch Port Modules

PMs not factory installed in a Magnum 6K32F modular slot.

Installation instructions, with illustrations

possible. Refer to Chapter 5 for specific return procedures.

5.1 Inspecting the Package and Product

as the switch catches up with the traffic flow.

functionality, and status displays.

5.2 6KPM Module Description

This package should contain:

normal operation.

6K32F Series PMs

Page 54 of the GarrettCom Managed Ethernet Switch (6K32FR) user manual — T-
Page 54 · click to enlarge
Page 54

capability for copper ports, the 6 or 8-port interfaces are designed to support all

provide two, four, six or eight ports for connecting Ethernet segments with its

RJ-45 ports or used for COMBO module is set as (=) as other ports.

5.2.1 6KP6-RJMST, 4@10/100Mbps RJ-45 and 2@100Mb multi-mode FX-ST “twist lock” Combo Module

GarrettCom Managed Ethernet Switch (6K32FR) — 5.2.1 6KP6-RJMST, 4@10/100Mbps RJ-45 and 2@100Mb multi-mode FX-ST “twist lock” Combo Module diagram (page 54)
Fig. 34 · 5.2.1 6KP6-RJMST, 4@10/100Mbps RJ-45 and 2@100Mb mul…

segments. When installed in a Magnum 6K32F Series Managed Switch, the copper port

supports the standard distance 100m on each port and the fiber port supports fiber optic

ps distance limits, i.e., typically 2km at full-

standard Ethernet media types at 10 or 100Mps speed. Each 6K32F PM can

Link (LK) LED that indicates proper connectivity with the remote device when lit, and

5.2.1a 6KP6-RJ10ST, 4@10/100Mbps RJ-45 and 2@10Mb multi-mode FX-ST “twist lock” Combo Module

Each 6K PM is individually described in the following sections.

Each port has an Activity (ACT) LED indicating packets being received, a

Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08)

modular slot. Since the Magnum 6K32F Series Switches have dual-speed

FDX/HDX LED to indicate full-duplex mode when lit (or half-duplex when off). T

The 6KP6-RJ10ST is a six port combo module that looks similar to the 10

T-

10/100 LED indicates the speed, if the LED is ON 100Mbps if it is OFF 10Mbps.

For a list of 6K32F Series Port Module types, refer to Section 1.2

combo module with the exception of 10Mb speed at the ST fiber module. The S

individual connector type and media.

cable distances up the IEEE-standard 100Mb

d 412m at half-duplex.

6KP6-RJMST is a combo 6

10/100Mbps and fiber optic

ports at 100MB. The Combo

port module of RJ-45’s at

connectors and dual speed

module is equipped with

connector functions as a f

optic transceiver to sup

copper ports. The ST-

Show 8 more labels / short text on this page
0Mb · he · iber · port · The Magnum · 100BASE-FX network · dual-mode ST-type · duplex an
Page 55 of the GarrettCom Managed Ethernet Switch (6K32FR) user manual — F
Page 55 · click to enlarge
Page 55
GarrettCom Managed Ethernet Switch (6K32FR) — 5.2.1b 6KP4-F10ST, 4@10Mb multi-mode FX-ST “twist lock” Module diagram (page 55)
Fig. 35 · 5.2.1b 6KP4-F10ST, 4@10Mb multi-mode FX-ST “twist lo…

5.2.1c 6KP4-FLSTFX, 2@10Mb and 2@100Mb multi-mode FX-ST “twist lock” Module

segments. When installed in a Magnum 6K32F Series Managed Switch, the copper port

supports the standard distance 100m on each port and the fiber port supports fiber optic

E-standard 10Mbps distance limits, i.e., typically 2km at

Link (LK) LED that indicates proper connectivity with the remote device when lit, and

.2.1b 6KP4-F10ST, 4@10Mb multi-mode FX-ST “twist lock” Module 5

The Magnum 6KP4-FLSTFX is a combo fiber module with two 10Mb + two

Each port has an Activity (ACT) LED indicating packets being received, a

FDX/HDX LED to indicate full-duplex mode when lit (or half-duplex when off). Th

lti-mode fiber. (Single-

Each port has an Activity (ACT) LED indicating packets being received, a

connect their legacy 10Mb network to the Magnum 6K32F Series switch. They also

Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08)

if it is OFF,.

duplex hub to connect to the switch through 10Mb fiber ports. It supports distances

100Mb multi-mode fiber module for a total of 4 ST-Fiber ports. All four fiber ports

ST connectors and configured as 10Mb Half-duplex by default for 10Mb fiber and

100Mb Full duplex for the 100Mb fiber. The 10Mb ST-fiber ports allow the user to

connector functions as a fiber optic transceiver to support 10BASE-FX network

Link (LK) LED indicating proper connectivity with the remote device when li

DX/HDX LED indicating full-duplex mode when lit (or half-duplex if off).

10/100 LED indicates the speed, 100Mbps if the LED is ON, 10Mbps

according to the 10Base-FL standard i.e, 2Km distance for mu

m 10Km distance may be available as a special order).

The Magnum 6KP4-F10ST is a

10Mb multi-mode fiber module

with 4 ST-Fiber ports. All four

ST-fiber ports allow the user to

2F

fiber ports are ST connectors

and configured as 10Mb Half-

duplex by default. The 10Mb

Series switch. They also prov

a convenient way for the half

cable distances up to the IEE

x and half-duplex.

network to the Magnum 6K3

connect their legacy 10Mb

F

Show 6 more labels / short text on this page
e · are · t, and · ide · full-duple · ode for
Page 56 of the GarrettCom Managed Ethernet Switch (6K32FR) user manual — F
Page 56 · click to enlarge
Page 56

While the functionality of these two modules is essentially the same, the 6KP6-

provide a convenient way for the half duplex hub to connect to the switch through 10Mb

GarrettCom Managed Ethernet Switch (6K32FR) — 5.2.2. 6KP6-RJMSC 4@10/100Mbps RJ-45 and 2@100Mb multi-mode FX-SC diagram (page 56)
Fig. 36 · 5.2.2. 6KP6-RJMSC 4@10/100Mbps RJ-45 and 2@100Mb mul…

6KP6-RJSSC 4@ 10

GarrettCom Managed Ethernet Switch (6K32FR) — 6KP6-RJSSC 4@ 10 diagram (page 56)
Fig. 37

fiber ports. Whereas the 100Mb ST module allows it to connect the 100Mb demand of

the Switch devices. It supports distances according to the 10Base-FL standard i.e, 2Km

lti-mode fiber. (Single-mode for 10Km distance may be available as a

5 and 2@100Mb multi-mode FX-SC

5.2.3 /100Mbps RJ-45 Ports and 2@100Mbps single-mode

Each port has an Activity (ACT) LED indicating packets being received, a

Link (LK) LED indicating proper connectivity with the remote device when lit, and

Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08)

JMSC is equipped with an SC-type "snap-in" connector instead of an ST-type.

hen lit (or half-duplex if off).

.2.2. bps RJ-4

DX/HDX LED indicating full-duplex mode w

, and the same face-plate lettering.

5 6KP6-RJMSC 4@10/100M “snap-in” Fiber connector

RJMSC is also a Combo 6 Port

The Magnum 6KP6-RJSSC is

provides an advantage through

10/100Mb RJ-45 ports along

with 2 multi-mode 100Mbps

fiber optic transceivers all in

one module. This is similar t

the 6KP6-RJMST. It has the

equipped with 4 dual speed

mode SC-type connectors. It

same LEDs indicating port

copper ports and 2 Single-

combining copper and Fibe

module equipped with 4

activity (ACT), Link (LK

FDX / HDX and 10/100

also a Combo module

s der).

F

R

Show 10 more labels / short text on this page
), and · The Magnum 6KP6- · o · snap- · r · FX-SC-type, “ · in” connector · distance for mu · pecial or · operation
Page 57 of the GarrettCom Managed Ethernet Switch (6K32FR) user manual — F
Page 57 · click to enlarge
Page 57

e 6KP6-RJMSC, the label

5.2.4 per port and 2@100Mbps single-mode

6KP6-RJSSCL 4 @ 10/100 Mb cop

copper port, which is 100Mbps when the LED is

copper supporting the 100m distance and Fiber supporting the multi-mode fiber cable.

The 6KP6-RJSSC, when installed in a Magnum 6K32F Series Switch operate

-mode and cable lengths can be as

Link (LK) LED that indicates proper connectivity with the remote device when lit, and

speed copper ports and 2 Single-mode (Long Reach) SC-type connectors. It provides a

combination of copper and Fiber functions in one module to the 6K32F Series Switche

Link (LK) LED indicating proper connectivity with the remote device when lit, and a

6KP6-RJ10ST 4 @ 10/100 Mb coppe

functions in one module of the 6K32F Series Switch supporting four Copper and two

Each port has an Activity (ACT) LED indicating packets being received, a

The Magnum 6KP6-RJSSC is also a Combo module equipped with 4 dual

g four Copper and two single-mode (Long-Reach) fiber network segments.

Each port has an Activity (ACT) LED indicating packets being received, a

FDX/HDX LED indicating full-duplex mode when lit (or half-duplex when off). The

5.2.4a r port and 2@10Mbps multi-mode

The Magnum 6KP6-RJ10ST is also a Combo module equipped with 4 dual

The 6KP6-RJ10ST, when installed in a Magnum 6K32F Series Switch has

Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08)

The 6KP6-RJSSC, when installed in a Magnum 6K32F Series Switch has

speed copper ports and 2 multi-mode 10 Mb fiber ST-type connectors. It provides a

FDX/HDX LED to indicate full-duplex mode when lit (or half-duplex when off).

This allows it to connect the legacy network 10Mb requirement in the network. Ea

has an Activity (ACT) LED indicating packets being received, a Link (LK) LED

10/100 LED indicates 100Mbps speed when lit and 10Mbps speed when off. To

combination of copper and Fiber functions in one module to the 6K32F

g four Copper and two 10Mb of ST fiber network segments.

copper supporting the 100m distance and Fiber supporting single

f as much as 40+ Km (see Power Budget, Section 4.5)

distinguish the single-mode 6KP6-RJSSC from the multi-mod

Sgl. M.” is at the top of the faceplate of the 6KP6-RJSSC.

on copper at the 100m distance. The Fiber is single

25+ Km (see Power Budget, Section 4.5)

10/100 LED indicates the speed for the

ON and 10 Mb when the LED is OFF.

ode fiber network segments.

F

Show 15 more labels / short text on this page
a · ch port · s · s, · Series Switches, · The · supportin · -mode fiber cable · L-ST-type, “twist-lock” connector · FX-SC-type, “snap-in” connector · single-m · much as · lengths o · supportin · “
Page 58 of the GarrettCom Managed Ethernet Switch (6K32FR) user manual — Factor and 2@ 10Mb Multi-mode ST-Fiber port
Page 58 · click to enlarge
Page 58
GarrettCom Managed Ethernet Switch (6K32FR) — 5.2.5 6KP8-MTRJ, 8 @100Mb multi-mode FX , MTRJ Small-Form-factor diagram (page 58)
Fig. 38 · 5.2.5 6KP8-MTRJ, 8 @100Mb multi-mode FX , MTRJ Small…

.2.5 6KP8-MTRJ, 8 @100Mb multi-mode FX , MTRJ Small-Form-factor 5

The functionality of this 100BASE-FX multi-mode 8 Port module is essentially

connector supports fiber optic cable distances up to the IEEE-standard 100Mbps distance

The functionality of this 100BASE-FX multi-mode 4 port module is essentially

LEDs per port indicating port activity

The 6KP6-RJ10ST is a combo module with two different kinds of fiber flavor

with two different speeds. The top four ports of MTRJ Small form factor fiber support a

ED

pper port, which is 10Mbps when the LED is ON and 10

5.2.5a 6 J Small-FormKP6-MT10ST, 4 @100Mb multi-mode FX , MTR

100Mb full-duplex, whereas the bottom two ports multi-mode ST-Fiber support 10Mb

limits, i.e., typically 2km at full-duplex and 412m at half-duplex. The 10Mb Multi-mod

r supports the standard fiber optic distance limit of 2Km at Full and

Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08)

indicating proper connectivity with the remote device when lit, and a FDX/HDX L

0Mbps distance limits, i.e., typically 2km at full-

indicating full-duplex mode when lit (or half-duplex when off). The 10/100 LED

When installed in a Magnum 6K32F Series Switch, the 100Mb MTRJ

half-duplex. This combo module provides more flexibility to the user to conn

le Mb fiber as well as 100Mb to the Magnum 6K32F Series Switch.

Factor and 2@ 10Mb Multi-mode ST-Fiber port

the same as the ST and SC-types. It has the same

ACT), Link (LK), and FDX or HDX operation.

desktop” Ethernet connectivity. When

Magnum 6KP8-MTRJ is a

MTRJ-type connector. It looks almo

installed in a Magnum 6K32F Series

Switch, it supports fiber optic cable

multi-mode fiber optic 8-port modu

equipped with a small-form-factor

like an RJ-45 port, but it is black in

color. The MT-RJ’s small size and

ease of connection make it a good

choice for 100Mbps “fiber-to-the-

distances up the IEEE-standard 10

duplex and 412m at half-duplex.

indicates the speed for the co

Mb when the LED is OFF.

lex both.

Show 9 more labels / short text on this page
e · t · ect their · le · st · ST-Fiber connecto · gacy 10 · Half-dup · (
Page 59 of the GarrettCom Managed Ethernet Switch (6K32FR) user manual — 5.2.7 00Mbps multi-mode 6KP8-MLC, 8 ports @ 1 C Small-Form Factor L
Page 59 · click to enlarge
Page 59

the same as the ST and SC-types. It has the same LEDs per port indicating port activity

GarrettCom Managed Ethernet Switch (6K32FR) — 5.2.6 6KP8-45MT, 4@ 10/100Mbps RJ-45 and 4@100Mb multi-mode FX , MTRJ Small-Form-Factor diagram (page 59)
Fig. 39 · 5.2.6 6KP8-45MT, 4@ 10/100Mbps RJ-45 and 4@100Mb mul…
GarrettCom Managed Ethernet Switch (6K32FR) — 5.2.6 6KP8-45MT, 4@ 10/100Mbps RJ-45 and 4@100Mb multi-mode FX , MTRJ Small-Form-Factor diagram (page 59)
Fig. 40 · 5.2.6 6KP8-45MT, 4@ 10/100Mbps RJ-45 and 4@100Mb mul…

indicating packets being received, a Link (LK) LED indicating proper connectivity with

5.2.6 6KP8-45MT, 4@ 10/100Mbps RJ-45 and 4@100Mb multi-mode FX , MTRJ Small-Form-Factor

dule is a combo module with copper and fiber

wiring closets while providing the advantage of “future-proof” fiber optic technology.

The cable end is a “plug-in” connector with both fiber strands terminated in

one housing that cannot be improperly inserted. Each port has an Activity (ACT) LED

The compact size of the LC connector reduces the size of wiring panels in

Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08)

s also act similarly.

5.2.7 00Mbps multi-mode 6KP8-MLC, 8 ports @ 1 C Small-Form Factor L

tandard distances as mentioned on 5.2.3. and the LEDs

ACT), Link (LK), and FDX or HDX operation (

distance limits, i.e., typically 2km at

full-duplex and 412m at half-duplex.

primarily in 100Mbps fiber-to-the-

supports fiber optic cable distances

up to the IEEE-standard 100Mbps

desktop links. When installed in a

Magnum 6K32F Series Switch, it

eight-port multi-mode fiber LC

with 4 10/100 RJ-45 ports

ports on one module. The

and 4 MTRJ fiber ports.

Switch, it supports the

MTRJ type ports. The

small size of MTRJ

When installed in a

Show 12 more labels / short text on this page
8-45MT Mo · s an · connector “small-form-factor” used · Magnum 6KP8-MLC i · The Magnum 6KP · more · 6KP8-45MT is equipped · s · Magnum 6K32F Serie · (Small Form Factor) · advantage of placing · connectors give an
Page 60 of the GarrettCom Managed Ethernet Switch (6K32FR) user manual — factor and 4@ 10/100 Mbps RJ-45 Connector
Page 60 · click to enlarge
Page 60

the remote device when lit, and a FDX/HDX LED indicating full-duplex mode when lit

When installed in a Magnum 6K32F Series Switch, it supports the standard distances as

and shielded twisted pair (STP) cable connections. The 6KP8-RJ45 module is equipped

GarrettCom Managed Ethernet Switch (6K32FR) — 5.2.8 6KP8-45LC, Combo 4@ 100Mbps multi-mode -LC small-form diagram (page 60)
Fig. 41 · 5.2.8 6KP8-45LC, Combo 4@ 100Mbps multi-mode -LC sma…

with a Media Dependent Auto-Crossover (MDI-X) switch, which controls all ports for

connection. This feature eliminates the need for a special twisted pair crosso

5.2.8 -LC small-form 6KP8-45LC, Combo 4@ 100Mbps multi-mode

GarrettCom Managed Ethernet Switch (6K32FR) — 5.2.8 -LC small-form 6KP8-45LC, Combo 4@ 100Mbps multi-mode diagram (page 60)
Fig. 42 · 5.2.8 -LC small-form 6KP8-45LC, Combo 4@ 100Mbps mul…

Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08)

as mentioned above. p

factor and 4@ 10/100 Mbps RJ-45 Connector

.2.9 6KP8-RJ45 (Twisted Pair), 10/100Mb 8-Port 5

er mentioned on 5.2.8. and the LEDs also act similarly

cable when connecting to a hub or another switch.

LC( Small form factor) multi-mode fiber ports.

negotiating capability on each

emissions and will allow both

unshielded twisted pair (UTP)

Fiber (Small Form Factor) L

type ports. The small size of

twisted pair segments of any

connector, and offers 10/100

(or half-duplex when off).

combination of copper and

advantage of having more

ports on one module. The

6KP8-45LC is equipped w

6KP8-45LC Module is a

LC connectors allows an

standard length. It is equi

with an eight-port RJ-45

4 10/100 RJ-45 ports an

combo module with a

full / half-duplex auto-

port. The RJ-45 conne

Show 9 more labels / short text on this page
cascaded ver · ith · pped · ctor is · d 4 · The 6KP8-RJ45 · module supports Ethernet · The Magnum · shielded to minimize
Page 61 of the GarrettCom Managed Ethernet Switch (6K32FR) user manual — NOTE:
Page 61 · click to enlarge
Page 61
GarrettCom Managed Ethernet Switch (6K32FR) — 5.2.10a. PoE (Power Pass-through), model P6KP8V-RJ45 (MDIX), 10/100Mb 8-port diagram (page 61)
Fig. 43 · 5.2.10a. PoE (Power Pass-through), model P6KP8V-RJ45…

Aut J- o-crossover (MDIX), which allow the RJ-45 ports to automatically Link with any R

could produce high (greater than 2500V ) levels of ground potential rise (GPR)

during line-to-ground fault conditions. The 6K32 passes the 1613specifications

45 port are per the standard for up-links using twisted pair wiring, i.e., the transmit

and the receive pairs are exchanged: 1 = transmit+, 2 = transmit-, 3 = receive+, 6 =

for zero packet loss with fiber ports & with RJ45 ports used as indicated here.

dard. The Power Pass-through PoE modules are totally dependent

FDX/HDX LED to indicate full-duplex mode when lit (or half-duplex when off), and a

users twisted pair wiring1 = receive+, 2 = receive-, 3 = transmit+, 6 = transmit-,

other pins not used. When the TP crossover push-button is UP, the pins of the RJ-

for Power SubstationsIn support of the IEEE 1613 Class 2 standard, GCI

telecommunication multiplexers installed in close proximity (i.e., less than 2

PoE (Power Pass-through), model P6KP8V-RJ45 (MDIX), 10/100Mb 8-

The PoE RJ-45 ports act similar to regular RJ-45 ports, except they have the

Each port has an Activity (ACT) LED indicating packets being received, a

Link (LK) LED that indicates proper connectivity with the remote device when lit, a

45 device and eliminate the use of cross-over cable. The RJ-45 pins normally (TP crossover switch) are per the standard for hubs-to-

substation applications to interface to field devices across distances which

Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08)

advises that, for substation applications, the RJ-45 ports are intended for

meters or 6.5ft) to the 6K32. It is not recommended to use these ports in

g power on each port to power up the PD devices, per the

lso available with mix –n-match with fiber modules. Please check the ordering

connectivity to other communication equipment such as routers or

“10/100” LED indicating 100Mb when lit (or 10 Mbps when off).

receive-, other pins not used.

with POE option. The 8-

least 15watts to power

up the PoE PD devices.

RJ45 ports are enhance

RJ45 POE modules are

IEEE802.3af PoE stan

supply to support mor

RJ-45 (10/100) ports.

Each port requires at

upon the powerful -

In this Fig. the top 8-

NOTE:

5.2.10a.

Show 7 more labels / short text on this page
and · d · e · capability of providin · 48VDC input power · port · a
Page 62 of the GarrettCom Managed Ethernet Switch (6K32FR) user manual — 5.2.10b. PoE(Power Inside), model PI6KP8-45RJ (MDIX), 10/100Mb 8-port
Page 62 · click to enlarge
Page 62

roperly to an 803.af compliant PD device on that port.

orts. The 4-RJ45 POE

ed properly to an 803.af compliant PD device on that port.

TIVITY LEDS are combined on the PoE modules into one LED

. The PoE LED is ON when the attached PD is drawing power from th

through, so the 48VDC power source must be strong enough to provide power

ports with PD devices connected (up to

  • wer

n-PoE devices are connected, the PoE LED is OFF. Operation of Ethernet data

  • 45 port

The PoE RJ-45 ports act similar to regular RJ-45 ports, except they have the

are also available with mix –n-match fiber modules. Please check the orderin

regular (non-PoE) RJ-45 modules as shown in Fig 2. When the PoE port is in use, the

The LEDs on 6KP8-RJ45- PoE modules are slightly different compared to

is coming to the PoE ports for some reason, all the PoE port LEDs are ON

IEEE802.3af PoE standard. Only 4 x RJ-45 (10/100) ports max. support POE (Power

Inside) option in one 6K-unit. In this Fig. the top 4-RJ45 ports are enhanced with the

The LEDs on 6KP8-RJ45- PoE modules are slightly different compared to

Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08)

In the case where the 48VDC power in not internally connected and no po

to indicate a trouble condition. The ports will still operate

regular (non-PoE) RJ-45 modules as shown in Fig 2. When the PoE port is in use,

n-PoE devices are connected, the PoE LED is OFF. PoE does not affect

For PoE devices, each RJ-45 PoE port supports only 802.3af complaint

The PoE ports in Magnum 6K’s with 48VDC power input act as a pass-

PoE(Power Inside), model PI6KP8-45RJ (MDIX), 10/100Mb 8-port

For non-PoE devices connected, the PoE port will act as a normal RJ-

capability of providing power on each port to power up the PD devices, per the

and the PoE LED is OFF. No power is being sent out from the port.

POE option whereas the bottom 4- RJ-45 ports are normal MDIX p

information Sec.1.2. for all the various PI6K PoE module options.

on Sec.1.2 for all the various P6K PoE modules option.

s rked as LINK/ACT, as shown in the diagram.

to the 6K switch and to all the 8 RJ-45

PoE LED is ON when connected p

properly for data traffic.

operation of Ethernet data traffic.

15 watts per PoE port).

PoE LED is ON when connect

port.

5.2.10b.

Show 14 more labels / short text on this page
e · modules g · the · simultaneously · LINK and AC · s Summary L · devices · that i ma · PoE ED · informati · When no · When no · • · •
Page 63 of the GarrettCom Managed Ethernet Switch (6K32FR) user manual — .2.11 @ 10/ 5 6KP8-45-2MT, 6 FX , MTRJ Small-Form-F
Page 63 · click to enlarge
Page 63

port. e

on the PoE modules into one LED

GarrettCom Managed Ethernet Switch (6K32FR) — 5.2.11 6KP8-45-2MT, 6@ 10/100Mbps RJ-45 and 2@100Mb multi-mode FX , MTRJ Small-Form-Factor diagram (page 63)
Fig. 44 · 5.2.11 6KP8-45-2MT, 6@ 10/100Mbps RJ-45 and 2@100Mb…

devices. The PoE LED is ON when the attached PD is drawing power from th

must be strong enough to provide power

to the 6K switch and to all the 8 RJ-45 ports with PD devices connected (up to

100Mbps RJ-45 and 2@100Mb multi-mode actor

GarrettCom Managed Ethernet Switch (6K32FR) — 100Mbps RJ-45 and 2@100Mb multi-mode actor diagram (page 63)
Fig. 45 · 100Mbps RJ-45 and 2@100Mb multi-mode actor
  • For non-PoE devices connected, the PoE port will act as a normal RJ-45 port

on, all the PoE port LEDs are ON

Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08)

15 watts per PoE port). In the case where the 48VDC power in not internally connected and no po

simultaneously to indicate a trouble condition. The ports will still operate

For P • oE devices, each RJ-45 PoE port supports only 802.3af complaint

The PoE ports in Magnum 6K’s with 48VDC power input act as a pass-

ports. When installed in a Magnum 6K32F Series Switch, it supports the standard

and the PoE LED is OFF. No power is being sent out from the port.

distances as mentioned on 5.2.3. and the LEDs also act similarly.

hat is marked as LINK/ACT, as shown in the diagram

. t

LINK and ACTIVITY LEDS are combined

  • s for some reas

through, so the 48VDC • power source

.2.11 @ 10/ 5 6KP8-45-2MT, 6 FX , MTRJ Small-Form-F

is coming to the PoE port

properly for data traffic.

45-2MT eight port Module is a

sizes of MTRJ connectors give

traffic is not affected by PoE.

an advantage of placing more

combo module with copper a

MTRJ type ports. The small

fiber ports on one module. T

with six 10/100 RJ-45 ports

and two 100Mb MTRJ fiber

fiber (Small Form Factor)

Show 7 more labels / short text on this page
wer · nd · he · The Magnum 6KP8- · 6KP8-45-2MT is equipped · L s Summary · PoE ED
Page 64 of the GarrettCom Managed Ethernet Switch (6K32FR) user manual — .2.12 GBIC-SXSC Gigabit fiber(1000Mb), multi-mode SC Connector 5
Page 64 · click to enlarge
Page 64

removing the transceiver, press the clips on either side of the transceiver at the same time

5.2.11a 6KP8-45-2LC, 6@ 10/100Mbps RJ-45 and 2@100Mb single-mode FX , LC Small-Form-Factor

GarrettCom Managed Ethernet Switch (6K32FR) — 5.2.11a 6KP8-45-2LC, 6@ 10/100Mbps RJ-45 and 2@100Mb single-mode FX , LC Small-Form-Factor diagram (page 64)
Fig. 46 · 5.2.11a 6KP8-45-2LC, 6@ 10/100Mbps RJ-45 and 2@100Mb…

The GBIC transceiver has been offered in the modular slot with multiple options as per

the user requirement. The two Giga port has been offered as GBPM-2OTX (fiber or RJ-

45), whereas the single Gigabit module comes in options of G+2 (100Mb fiber ports) or

Each port has an Activity (ACT) LED indicating packets being received and a

.2.12 GBIC-SXSC Gigabit fiber(1000Mb), multi-mode SC Connector 5

GarrettCom Managed Ethernet Switch (6K32FR) — .2.12 GBIC-SXSC Gigabit fiber(1000Mb), multi-mode SC Connector 5 diagram (page 64)
Fig. 47 · .2.12 GBIC-SXSC Gigabit fiber(1000Mb), multi-mode SC…

The GBIC transceiver is fastened using snap-in clips. Insert the transceiver

Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08)

up to the IEEE 802.3z standard 1000Mbps distance limits, i.e., 550m at full duplex.

(take care to insert it the right way up, arrows on top) until it clicks in place. While

fiber ports. When installed in a Magnum 6K32F Series Switch, it supports the stan

Link (LK) LED indicating proper connectivity with the remote device when lit.

distances as mentioned on 5.2.4. and the LEDs also act similarly.

G+4(10/100 RJ-45 ports) as shown in the above figure.

The Magnum GBIC-SXSC is

applications. It supports cable distances

a multi-mode Gigabit fiber connector

equipped with SC type connectors and

can be easily snapped in and out. The

Gigabit fiber ports are most popular as

combo module with copper and

type fiber ports. The small size

advantage of placing more ports

RJ-45 ports and 2 Single-mode

45SLC eight port Module is a

fiber (Small Form Factor) LC

on one module. The 6KP8-45-

2SLC is equipped with 6 10/10

and pull the transceiver out.

of LC connectors give an

dard · server-to-switch and switch-to-switch · The Magnum 6KP8-

Page 65 of the GarrettCom Managed Ethernet Switch (6K32FR) user manual — 5.2.12a GBPM-2OTX (Two Gigabit option)
Page 65 · click to enlarge
Page 65
GarrettCom Managed Ethernet Switch (6K32FR) — 5.2.12a GBPM-2OTX (Two Gigabit option) diagram (page 65)
Fig. 48 · 5.2.12a GBPM-2OTX (Two Gigabit option)

2OTX also meets the requirement for those applications where a managed Gigabit media

with SC type connectors and can be easily snapped in and out. The Gigabit fiber ports are

distances up to the IEEE 802.3z standard 1000Mbps distance limits, i.e., 10, 25, 40, 70 or

converter is required. The two Gigabit slot can be filled with copper/Fiber or mix as per

models are available for both multi-mode (550m) and single-mode (10, 25, 40, 70, 120)

The Magnum GBIC-LXSC is a single-mode Gigabit fiber connector equipped

GarrettCom Managed Ethernet Switch (6K32FR) — 5.2.12a GBPM-2OTX (Two Gigabit option) diagram (page 65)
Fig. 49 · 5.2.12a GBPM-2OTX (Two Gigabit option)

The Dual Gigabit port option for the modular slot provides a wide option of

choice for various Gigabit transceivers covering a long range of distance. The GBPM-

industry-standard GBICs to provide Gigabit (Gb) transceivers media flexibility. GBIC

Each port has a Full and Half Duplex (F/H) Activity, (ACT) LED indicating

5.2.12b GBIC-LXSC Gigabit fiber (1000Mb), multi-mode SC Connector

The 6K32-Series Gigabit Modules provide a GBIC opening for insertion of

packets being received and a Link (LK) LED indicating proper connectivity with the

most popular as server-to-switch and switch-to-switch applications. It supports cable

Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08)

km fiber options, and Gigabit copper as well, with new models appearing often.

120Km at full duplex, and depend upon the Gigabit modules used.

5.2.12a GBPM-2OTX (Two Gigabit option)

speed with multiple choice of copper

or Fiber or mix for the modular slot

modules (max.) can be configured in

offered a wide selection of Gigabit

the modular slot for GBPM-2OTX.

module). While up to two Gigabit

via GBPM-2OTX (2 x Giga

remote device when lit.

the application.

The Magnum 6K32-Series

Page 66 of the GarrettCom Managed Ethernet Switch (6K32FR) user manual — 6.0 TROUBLESHOOTING
Page 66 · click to enlarge
Page 66
GarrettCom Managed Ethernet Switch (6K32FR) — 5.2.13 6KM-BLNK diagram (page 66)
Fig. 50

suggestions listed below prior to contacting your supplier. However, if you are unsure of

ION,

intended to help locate, identify and correct these types of problems. Please follow the

the procedures described in this section or if the Magnum 6K32F Series Switch is not

instead contact your supplier

Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08)

consistently high performance in all network environments. The installation of a

Magnum 6K32F Series Switch is a straight-forward procedure (see INSTALLAT

Section 3.0); the operation is also straight-forward and is discussed in Section 4.

Should problems develop during installation or operation, this section is

All Magnum Ethernet products are designed to provide reliability and

Four screws hold the 6KM-BLNK in place.

performing as expected, do not attempt to repair the unit;

for assistance or contact GarrettCom Customer Support.

LED indicating packets being received and a

connectivity with the remote device when lit.

GBPM-2OTX (fiber or RJ-45), whereas the

Each port has an Activity (ACT)

single Gigabit module comes in flavor of

G+4(10/100 RJ-45 ports) or G+2 (100Mb

fiber ports) as shown below in the above

The two Giga port has been offered as

6.0 TROUBLESHOOTING

link (LK) LED indicating proper

5.2.13 6KM-BLNK The 6KM-BLNK is a

blank face plate or cover plate t

must be installed in any empty

6K32F Series PM slot to mainta

er cooling air flow, safety,

figure.

etc.

hat · in · prop

Page 67 of the GarrettCom Managed Ethernet Switch (6K32FR) user manual — 6.1 Before Calling for Assistance
Page 67 · click to enlarge
Page 67
3. Make sure that an AC power cord is properly attached to each Magnum 6K32F
5. Always check your Switch configuration, especially Auto-negotiation behavior
1. If difficulty is encountered when installing or operating the unit, refer back to

Series Switch product, it is recommended that the problem device be replaced

with a known good device. Verify whether or not the problem is corrected. If

5. If the problem continues after completing Step 4 above, contact your supplier

of the Magnum 6K32F Series Switch unit or if unknown, contact GarrettCom,

the Installation Section of the applicable chapter of this manual. Also check

4. If the problem is isolated to a network device other than the Magnum 6K32F

to make sure that the various components of the network are interoperable.

Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08)

Series Switch unit. Be certain that each AC power cord is plugged into a

not, go to Step 5 below. If the problem is corrected, the Magnum 6K32F

c. The components involved in the problem; (complete Network diagram

d. Any particular application, environment, power spike that, when used,

2. Check the cables and connectors to ensure that they have been properly

impaired during installation. (About 90% of network downtime can be

functioning electrical outlet. Use the PWR LEDs to verify each unit is

1. A complete description of the problem, including the following points:

connected and the cables/wires have not been crimped or in some way

Inc.by fax, phone or email (support@garrettcom.com) for assistance.

Series Switch and its associated cables are functioning properly.

with other connected device to have proper setup tested.

Please be prepared to provide the following information.

attributed to wiring and connector problems.)

a. The nature and duration of the problem;

b. Situations when the problem occurs;

6.1 Before Calling for Assistance

6.2 When Calling for Assistance

appears to create the problem;

receiving power.

preferred)

Page 68 of the GarrettCom Managed Ethernet Switch (6K32FR) user manual — 6.3 Return Material Authorization (RMA) Procedure
Page 68 · click to enlarge
Page 68

All returns for repair must be accompanied by a Return Material Authorization

4. A record of changes that have been made to your network configuration prior
3. It is useful to include other network equipment models and related hardware,

including personal computers, workstations, terminals and printers; plus, the

https://rma.garrettcom.com/rma/rma_request_noaccount.php to fill out the form.

GarrettCom will carefully test and evaluate all returned products, will repair products

number(s). Include the date(s) that you purchased the products from your

Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08)

to the occurrence of the problem. Any changes to system administration

that are under warranty at no charge, and will return the warranty-repaired units to

the sender with shipping charges prepaid (see Warranty Information, Appendix A,

units under warranty. Testing and repair of product that is not under warranty will

GarrettCom reserves the right to charge for the testing of non-defective

2. An accurate list of GarrettCom product model(s) involved, with serial

for complete details). However, if the problem or condition causing the return

Failure symptoms, including a full description of the problem.

6.3 Return Material Authorization (RMA) Procedure

(RMA) number. To obtain an RMA number, please use this URL -

cannot be duplicated by GarrettCom, the unit will be returned as:

Name and phone number of your contact person.

Please have the following information readily available:

Packing List Number (or Sales Order Number)

procedures should all be noted in this record.

various network media types being used.

No Problem Found.

Name of your company / institution

Serial Number (or Invoice Number)

result in a customer (user) charge.

supplier.

Your shipping address · Date of installation · Product name

Page 69 of the GarrettCom Managed Ethernet Switch (6K32FR) user manual — Attn.: Customer Service
Page 69 · click to enlarge
Page 69

sheet or bag for shipping protection. ( You may retain all connectors and this

1. Package the unit carefully. It is recommended that you use the original container if available. Units should be wrapped in a "bubble-wrap" plastic

material. This material may cause electro-static shock damage to the unit.

CAUTION : Do not pack the unit in Styrofoam "popcorn" type packing

2. Clearly mark the Return Material Authorization (RMA) number on the outside of the shipping container.

GarrettCom, Inc. warrants its products to be free from defects in materials

Magnum 6K32F/FR/FC/FRC Managed Switch In tallat s ion and User Guide (05/08)

Should you need to ship the unit back to GarrettCom, please follow these

replace components in the products that prove to be defective at no charge other

product has been damaged by misuse, misapplication, or as a result of service or

This warranty will not be effective if, in the opinion of GarrettCom, the

Please complete the warranty card as this acts as a product registration,

and workmanship for a period of three (3) years from the date of shipment by

than shipping and handling, provided that the product is returned pre-paid to

inspecting any product returned for warranty repair which turns out not to be

During this warranty period, GarrettCom will repair or, at its option,

3. GarrettCom is not responsible for your return shipping charges.

GarrettCom reserves the right to make a charge for handling and

and mail it to GarrettCom within two weeks of your purchase.

APPENDIX A: WARRANTY INFORMATION

6.4 Shipping and Packaging Information

47823 Westinghouse Dr.

Attn.: Customer Service

modification other than by GarrettCom.

GarrettCom, Inc.

Installation Guide.)

4. Ship the package to:

instructions:

GarrettCom.

GarrettCom.

faulty.

Fremont, CA 94539-7437

Page 70 of the GarrettCom Managed Ethernet Switch (6K32FR) user manual — POWER
Page 70 · click to enlarge
Page 70

polarity connection, for example, will neither affect the Switch, its internal power supply,

The manual power “On-Off” Switch (optional) is used for powering the unit on

B1.0 SPECIFICATIONS FOR MAGNUM 6K32F SERIES SWITCHES, DC

functions of Magnum 6K32F Series Switch -48VDC, 24VDC and 125VDC models

This allows the Switch to operate only whenever DC power is correctly applied to the

B2.0 -48VDC, 24VDC and 125VDC POWER, THEORY OF OPERATION

GarrettCom Managed Ethernet Switch (6K32FR) — B1.0 SPECIFICATIONS FOR MAGNUM 6K32F SERIES SWITCHES, DC diagram (page 70)
Fig. 51

two inputs. It protects the Switch from incorrect DC input connections. An incorrect

Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08)

With the exception of the power supply, all specifications and

Power ConsumptionSame as for AC models (see Section 1.1)
Power ConsumptionSame as for AC models (see Section 1.1)
Power ConsumptionSame as for AC models (see Section 1.1)

Power Supply (Internal 125 VDC Option) Industrial Applications

DC Power Connector: 3 terminals: “ - “, “GND”, “+”

Power Supply (Internal 24 VDC Option) Industrial Applications

DC Power Connector: 3 terminals: “ - “, “GND”, “+”

DC Power Connector: 3 terminals: “ - “, “GND”, “+”

APPENDIX B : Internal DC Power Supply Options

nor will it blow the fuse in the internal power supply.

and off when it is placed into or taken out of service.

are identical to those listed in the main manual.

Input Voltage88 - 150 VDC
Input Voltage36 - 70 VDC
Input Voltage20 - 36 VDC

Power Supply (Internal -48VDC Option)

125VDC power options are designed using

diodes inside on each DC power input line

external source can only flow into the hub.

behind the two external power connection

The -48VDC, 24VDC and

terminals, so that the power from an

POWER

Page 71 of the GarrettCom Managed Ethernet Switch (6K32FR) user manual — B4.0 INSTALLATION
Page 71 · click to enlarge
Page 71

The –48VDC solution is particularly useful in the telecommunication industry,

other communication companies. In addition, many high availability equipment services,

facilities often use a battery backup system to maintain operations in the event of a power

environment, where it is common facilities to operate on 24VDC or 125VDC power. The

applications where -48VDC, 24VDC and 125VDC power is used as the primary power

where it is common for facilities to operate on -48VDC power. Such companies include

Series. The leads are identified as negative (-), positive (+), and chassis ground (GND).

The actual connection procedure is very straightforward. Simply connect the

source. The- 48VDC, 24VDC and 125VDC power configuration provides an Ethernet

regular and wireless telephone service providers, Internet Service Providers (ISPs) and

This section describes the installation of the -48 VDC, 24VDC and 125VDC

GarrettCom Managed Ethernet Switch (6K32FR) — APPENDIX B : Internal DC Power Supply Options diagram (page 71)
Fig. 52 · APPENDIX B : Internal DC Power Supply Options

The 24VDC and 125VDC solution are particularly useful in the Industrial

electrical generating plants, etc. The 24VDC applications are mainly in the Industrial

leads to the Magnum unit, beginning with ground. Ensure that each lead is securely

Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08)

Magnum 6K32F Series Fiber Switches are easily installed in a variety of

down lead posts. It is similar for 24VDC and 125VDC options on Magnum 6K32F

such as broadcasters, publishers, newspaper operations, brokerage firms and other

125VDC solution is mainly used in power utilities, such as electrical substations,

failure. It is also frequently used for computer system backup, management and

environment, such as factory floor, HVAC equipment, military equipment, etc.

networking solution utilizing a special power supply in a Managed Switch.

B3.0 APPLICATIONS FOR DC POWERED SWITCHES

power source leads to the -48 VDC, 24VDC

and 125VDC power terminal block on the

6K32F Series is located on the rear of the

unit and is equipped with three (3) screw-

-48VDC terminal block on the Magnum

Magnum 6K32F’s.(see photo at right).

operations monitoring equipment.

B4.0 INSTALLATION

In this picture, the

tightened.

Page 72 of the GarrettCom Managed Ethernet Switch (6K32FR) user manual — B6.0 ORDERING INFORMATION
Page 72 · click to enlarge
Page 72

125VDC, always use a digital voltmeter to measure the output voltage of the power supply and determine the lead which is more “+ve potential”. The more “+ve” voltage

1. Minimum 18AWG cable for connection to a Centralized DC power source. 2. Minimum 14AWG cable for connection to a earthing wiring. 3. Use only with Listed 10 A circuit breaker provided in building installation. 4. “Complies with FDA radiation performance standards, 21 CFR subchapter J.” or equivalent.
5. Fastening torque of the lugs on the terminal block: 9 inch-pound max. 6. Centralized DC Power Source cable securement, use at least Minimum 14AWG four cable ties to secure the cable to the rack at least 4 inches apart, with the

An ON-OFF manual switch is optional for DC power. This can be used to cut

To order the optional -48VDC power supply factory installed, add a suffix of

Before connecting hot lines to the Terminal Block of –48VDC, 24VDC or

“-48VDC” after the product’s standard model # Example: Magnum 6K32F-48VDC.

Similarly to order the optional 24VDC or 125VDC industrial specific power

supply factory installed, add a suffix of “ 24VDC” or “125VDC” after the product ‘s

standard model #. Example: Magnum 6K32F- 24VDC, Magnum 6K32F-125VDC.

Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08)

Operation of Magnum 6K32F Series Switches with the optional -48VDC,

24VDC and 125VDC power supply is identical to that of the standard AC-powered

the user may elect to Ground either + or - terminal to suit the customer’s use.

off power connections and as a RESET for the Magnum 6K32F Series Switch.

lead from 48V or –48V supply must be connected to the post labeled “+”.

first one located within 6 inches of the terminal block.

Please refer to Section 6.0 for troubleshooting

B4.1 UL Requirements for DC-powered units

B6.0 ORDERING INFORMATION

B7.0 TROUBLESHOOTING

B5.0 OPERATION

models.

Page 73 of the GarrettCom Managed Ethernet Switch (6K32FR) user manual — APPENDIX C: Internal DC Dual-Source Power Option
Page 73 · click to enlarge
Page 73

24VDC and 125VDC models with this Dual-Source option are identical to those listed in

C1.0 SPECIFICATIONS - FOR MAGNUM 6K32F SERIES FIBER SWITCH

GNDTerminal for “earth” or ground wire connection to the hub chassis
GNDTerminal for “earth” or ground wire connection to the hub chassis
GNDTerminal for “earth” or ground wire connection to the hub chassis

125VDC Dual-Source power supply are designed for installations where a battery plant

The functionality of the Magnum 6K32F Series Switch -48VDC, 24VDC and

DC Power ConnectorFirst Source: “A+”, “A -“ , 2nd Source “B - “, “B+”
DC Power ConnectorFirst Source: “A+”, “A -“ , 2nd Source “B - “, “B+”
DC Power ConnectorFirst Source: “A+”, “A -“ , 2nd Source “B - “, “B+”
GarrettCom Managed Ethernet Switch (6K32FR) — APPENDIX B : Internal DC Power Supply Options diagram (page 73)
Fig. 53 · APPENDIX B : Internal DC Power Supply Options

With the exception of the dual DC input power connections and the power

supply, all specifications and configuration options for the Magnum 6K32F -48VDC,

125VDC Dual-Source Option units is identical to the standard AC-powered models.

Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08)

the Magnum 6K32F Series Fiber Switches Installation and User Guide, including

The 6K32F Series-Switch models with the internal -48VDC, 24VDC and

is the power source, and where two separate power sources are utilized in order to

Power Supply (Internal, -48VDC Dual-Source, model # Dual-Src-48V)

Power Supply (Internal, 24VDC Dual-Source, model # Dual-Src-24V)

Power Supply (Internal, 125VDC Dual-Source, model # Dual-Src-24V)

C2.0 MAGNUM 6K32F SERIES, with -48VDC, 24VDC and 125VDC

APPENDIX C: Internal DC Dual-Source Power Option

InputTwo separate sources, each at 88 - 150 VDC
InputTwo separate sources, each at 36 - 70 VDC
InputTwo separate sources, each at 20 - 36 VDC

increase operational uptime and to simplify maintenance.

Appendix B “Internal DC Power Supply Option”

description of the Magnum 6K32F Switches.

Installation and User Guide for a detailed

Refer to the main sections of this

Dual-Source option

Page 74 of the GarrettCom Managed Ethernet Switch (6K32FR) user manual — C5.0 INSTALLATION
Page 74 · click to enlarge
Page 74

source can only flow into the unit. This allows the unit to operate whenever DC power is

normally draw its power from the DC source with the highest voltage at a given time.

b) The Switch unit will not allow power to flow from a higher voltage input to a lower

c) When one correct DC input is present, the Switch will receive power if the other DC

input is absent, or even if it is connected with reverse polarity or shorted or grounded.

internal power supply) because of the blocking action of the diodes. This is true even

secondary power terminals as negative (B-), positive(B+). The chassis “earth” or ground

d) Reverse polarity connections, if they should accidentally occur on either input, will

125VDC dual source leads to the -48VDC, 24VDC 7 125VDC power terminal block on

GarrettCom Managed Ethernet Switch (6K32FR) — APPENDIX B : Internal DC Power Supply Options diagram (page 74)
Fig. 54 · APPENDIX B : Internal DC Power Supply Options

(GND) is a threaded post with a #6 nut. The Dual Source terminal block for the 24VDC

not damage the Switch or power supply internally (nor will it blow the fuse in the

chassis on each DC power input line. A diode is placed in each of the four input lines

(behind the four external power connection terminals) so that power from an external

a) The Switch unit can receive power from either input, “A” or “B”. The hub will

with five (5) screw-down lead posts. If it is the reverse model it is located on the left

Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08)

The Dual-Source DC power option is designed using diodes inside of the

voltage input, i.e. the two DC power sources are not mixed together by the hub.

if one input connection is reversed while the Switch is operating from the other

This section describes the proper connection of the -48VDC, 24VDC and

C4.0 FEATURES AND BENEFITS OF THE DUAL-SOURCE DESIGN

e) The Switch will not receive power (and will not work) when both inputs are

rear. The primary terminals are identified as positive (A+), negative (A-), and the

C3.0 DUAL-SOURCE OPTION, THEORY OF OPERATION

simultaneously absent or are both incorrectly connected.

correctly applied to either or both of the two inputs

right rear of the unit and is equipped

The -48VDC terminal block on the

Magnum 6K32F Series Switch, as

shown in Fig C5.0 is located on the

C5.0 INSTALLATION

the Magnum 6Ks Switch

and 125VDC are similar.

(shown in Figure )

source.

Page 75 of the GarrettCom Managed Ethernet Switch (6K32FR) user manual — C6.0 ORDERING INFORMATION
Page 75 · click to enlarge
Page 75

125VDC, always use a digital voltmeter to measure the output voltage of the power supply and determine the lead which is more “+ve potential”. The more “+ve” voltage

1. Minimum 18 AWG cable for connection to a Centralized DC power source. 2. Minimum 14 AWG cable for connection to earthing wiring. 3. Use only with Listed 10 A circuit breaker provided in building installation. 4. “Complies with FDA radiation performance standards, 21 CFR subchapter J.” or equivalent.
5. Fastening torque of the lugs on the terminal block: 9 inch pound max. 6. Centralized DC Power Source cable securement, use at least four Minimum 14 AWG cable ties to secure the cable to the rack at least 4 inches apart with the

Dual-Src-48V for the regular DS model with no ON-OFF switch

The connection procedure is straightforward. Simply connect the DC leads to

the Switch’s power terminals, positive (+) and negative (-) screws. Ensure that each lead

The 24VDC and 125VDC terminal block on Magnum 6K32F Series is similar

ground, so the user may elect to Ground either + or - terminal to suit the customer’s

Before connecting hot lines to the Terminal Block of –48VDC, 24VDC or

Similarly, order the “Dual –source 24VDC” or “Dual-source 125VDC” as a

Or Dual-Src125V-Switch for models with the ON-OFF switch

Operation of the Dual-Source Magnum 6Ks-48VDC, 24VDC and 125VDC

The following must be adhered to in order to conform to UL requirements:

To order the optional Dual-Source -48VDC power supply factory installed,

order “Dual-Src48V” as a separate line item following the product model.

Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08)

or Dual-Src48V-SWITCH with the ON-OFF manual switch.

ExampleMagnum 6K32F-24VDC or Magnum 6K32F-125VDC

Dual-Src24V for regular models with no ON-OFF switch

lead from 48V or –48V supply must be connected to the post labeled “+”.

Switch models are identical to that of the standard models.

first one located within 6 inches of the terminal block.

separate line item following the product model.

to that described in the –48VDC information above.

ExampleMagnum 6K32F-48VDC

C6.0 ORDERING INFORMATION

C7.0 OPERATION

C5.1 UL Requirements

is securely tightened.

use.

Ask about the GarrettCom Managed Ethernet Switch (6K32FR)

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the GarrettCom Managed Ethernet Switch (6K32FR)

Be the first to ask — other owners or our team will answer.

Original document

GarrettCom Managed Ethernet Switch (6K32FR) manual PDF

75 pages·1.8 MB·Network Router·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…