UNVENTED (VENT-FREE) PROPANE/LP GAS LOG HEATERp.1VARIABLE MANUALLY-CONTROLLED MODELS ALSO DESIGN-CERTIFIEDp.1AS VENTED DECORATIVE APPLIANCESp.1OWNER’S OPERATION AND INSTALLATION MANUALp.1VFP18R VFP24R VFP30R 18", 24", and 30" Remote-Readyp.1HIp.1LOp.1REMOTEp.1OFFp.1ONp.1EMBER MASTER™p.1— Do not store or use gasoline or other flammablep.1SAFETY INFORMATIONp.2WARNINGSp.2SAFETY INFORMATION Continuedp.3UNPACKINGp.3LOCAL CODESp.3PRODUCT FEATURES OPERATIONp.3PRODUCT IDENTIFICATIONp.3SAFETY PILOTp.3PIEZO IGNITION SYSTEMp.3PRODUCT FEATURES Continuedp.4PROVIDING ADEQUATE VENTILATIONp.4Confined and Unconfined Spacep.4OPTIONAL REMOTE CONTROL ACCESSORIESp.4Unusually Tight Constructionp.4AIR FOR COMBUSTION AND VENTILATIONp.4AIR FOR COMBUSTION AND VENTILATION Continuedp.5DETERMINING FRESH-AIR FLOW FOR HEATER LOCATIONp.5Determining if You Have a Confined or Unconfined Spacep.5Ventilation Air From Outdoorsp.6INSTALLATIONp.7INSTALLATION AND CLEARANCESp.7(Vent-Free Operation Only)p.7INCHESp.7INSTALLATION Continuedp.8Minimum Noncombustible Material Clearancesp.8MANTEL CLEARANCESp.9(A)p.9Determining Minimum Mantel Clearancep.9Determining Minimum Mantel Clearance When Using a Hoodp.9INSTALLING HEATER BASE ASSEMBLYp.10CONNECTING TO GAS SUPPLYp.11Installation Items Neededp.11CHECKING GAS CONNECTIONSp.12ON POSITIp.12O POSp.12INSTALLING LOGSp.13LIGHTING INSTRUCTIONSp.14OPERATING HEATERp.14FOR YOUR SAFETYp.14READ BEFOREp.14LIGHTINGp.14AUTO OFF ONp.14OPERATING HEATER Continuedp.15TO TURN OFF GAS TOp.15APPLIANCEp.15Shutting Off Burners Only (pilot stays lit)p.15MANUAL LIGHTINGp.15PROCEDUREp.15OPTIONAL REMOTEp.15OPERATIONp.15Thermostat Control Operationp.15PILOT FLAME PATTERNp.16FRONT BURNER FLAME PATTERNp.16INSPECTING BURNERS Continuedp.17CLEANING AND MAINTENANCEp.17CLEANING BURNERS INJECTOR HOLDER AND PILOT AIR INLET HOLEp.17TROUBLESHOOTINGp.18OBSERVED PROBLEMp.18POSSIBLE CAUSEp.18REMEDYp.18TROUBLESHOOTING Continuedp.19SPECIFICATIONSp.21REPLACEMENT PARTSp.2118" Variable 24" Variable 30" Variablep.21PARTS UNDER WARRANTYp.21WIRING DIAGRAMp.21PARTS NOT UNDER WARRANTYp.21AUTOp.21
Page 1 of the FMI VFP18R user manual — — Do not store or use gasoline or other flammable
Page 1 · click to enlarge
Page 1

UNVENTED (VENT-FREE) PROPANE/LP GAS LOG HEATER

VARIABLE MANUALLY-CONTROLLED MODELS ALSO DESIGN-CERTIFIED

AS VENTED DECORATIVE APPLIANCES

OWNER’S OPERATION AND INSTALLATION MANUAL

VFP18R VFP24R VFP30R 18", 24", and 30" Remote-Ready

P

O

F

F

O

T

O

N

HI

LO

REMOTE

OFF

ON

EMBER MASTER™

— Do not store or use gasoline or other flammable

vapors and liquids in the vicinity of this or any other appliance. — WHAT TO DO IF YOU SMELL GAS

  • Do not try to light any appliance.
  • Do not touch any electrical switch; do not use any phone in your building.
  • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
  • If you cannot reach your gas sup plier, call the fire department. — Installation and service must be performed

WARNING: This appliance is for installa- tion only in a solid-fuel burning masonry, UL127 factory-built fireplace, or in an ap- proved ventless firebox. It is design certi- fied for these installations in accordance with ANS Z21.11.2. Exception: Do not in- stall this appliance in a factory-built fire- place that includes instructions stating it has not been tested or should not be used with unvented gas logs.

by a qualified installer, service agency, or the gas supplier.

This appliance may be installed in an aftermarket*, permanently located, manufactured (mobile) home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.

* AftermarketCompletion of sale, not for purpose of resale, from the manufacturer

Save this manual for future reference.

Page 2 of the FMI VFP18R user manual — WARNINGS
Page 2 · click to enlarge
Page 2

SAFETY INFORMATION

  • 4. This heater shall not be installed in a bedroom or bathroom, unless installed as a vented appliance (see Installing Damper Clamp Accessory for Vented Operation , page 10). 5. Before installing in a solid fuel burning fireplace, the chimney flue and firebox must be cleaned of soot, creosote, ashes, and loose paint by a qualified chimney cleaner. Creosote will ignite if highly heated. Inspect chimney flue for damage. If damaged, operate heater with flue damper closed. 6. If fireplace has glass doors, never operate this heater with glass doors closed. If you operate heater with doors closed, heat buildup inside fireplace will cause glass to burst. Also if fireplace opening has vents at the bottom, you must open the vents before operating heater. 7. To prevent the creation of soot, follow the instructions in Cleaning and Maintenance , page 17. 8. This log heater is designed to be smokeless. If logs ever appear to smoke, turn off heater and call a qualified service person. Note: During initial operation, slight smoking may occur due to log curing and heater burning manufacturing residues. 9. Before using furniture polish, wax, carpet cleaner, or similar products, turn heater off. If heated, the vapors from these products may create a white powder residue within burner box or on adjacent walls or furniture. 10. This heater needs fresh, outside air ventilation to run properly. This heater has an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS shuts down the heater if not enough fresh air is available. See Air for Combustion and Ventilation, pages 4 through 6. If heater keeps shutting off, see Troubleshooting, pages 18 through 20. 11. Do not run heater
  • where flammable liquids or vapors are used or stored
  • under dusty conditions 12. Do not use this heater to cook food or burn paper or other objects. 13. Do not use heater if any part has been exposed to or under water. Immediately call a qualified service technician to inspect the room heater and to replace any part of the control system and any gas control which has been under water.

Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies.

WARNINGS

Do not place clothing or other flammable material on or near the appliance. Never place any objects on the heater.

Heater base assembly becomes very hot when running heater. Keep children and adults away from hot surface to avoid burns or clothing ignition. Heater will remain hot for a time after shutdown. Allow sur- face to cool before touching.

Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, or nausea. If you have these signs, the heater may not be work- ing properly. Get fresh air at once! Have heater serviced. Some people are more af- fected by carbon monoxide than others. These include pregnant women, people with heart or lung disease or anemia, those under the influ- ence of alcohol, and those at high altitudes.

Carefully supervise young chil- dren when they are in the room with heater. When using the hand- held remote accessory, keep se- lector switch in the OFF position to prevent children from turning on burners with remote.

You must operate this heater with a fireplace screen in place. Make sure fireplace screen is closed before running heater.

Propane/LP Gas: Propane/LP gas is odor- less. An odor-making agent is added to the gas. The odor helps you detect a gas leak. How- ever, the odor added to the gas can fade. Gas may be present even though no odor exists.

Keep the appliance area clear and free from combustible materials, gasoline, and other flammable vapors and liquids.

Make certain you read and understand all warnings. Keep this manual for reference. It is your guide to safe and proper operation of this heater.

  • 1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases. 2. Do not place propane/LP supply tank(s) inside any structure. Locate propane/LP supply tank(s) outdoors. 3. If you smell gas
  • shut off gas supply
  • do not try to light any appliance
  • do not touch any electrical switch; do not use any phone in your building
  • immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions
  • if you cannot reach your gas supplier, call the fire department

2 105073

Page 3 of the FMI VFP18R user manual — PIEZO IGNITION SYSTEM
Page 3 · click to enlarge
Page 3

SAFETY INFORMATION Continued

UNPACKING

LOCAL CODES

Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code, ANS Z223.1, also known as NFPA 54*.

14. Do not operate heater if any log is bro- ken. Do not operate heater if a log is chipped (dime-sized or larger). 15. Turn heater off and let cool before ser- vicing, installing, or repairing. When using the hand-held remote accessory, make sure the selector switch is in the OFF position. Only a qualified service person should install, service, or repair heater. 16. When using the hand-held remote acces- sory, make sure the selector switch is in the OFF position when you are away from home for long periods of time. 17. This heater must not be connected to any external electrical source. 18. Operating heater above elevations of 4,500 feet may cause pilot outage. 19. To prevent performance problems, the use of a propane/LP fuel tank of less than 100 lb. capacity is not recommended.

*Available from:

1. Remove logs and heater base assembly from carton. Note: Do not pick up heater base assembly by the burner. This could damage heater. Always handle base assembly by grate. 2. Remove all protective packaging applied to logs and heater for shipment. 3. Check all items for any shipping damage. If damaged, promptly inform dealer where you bought heater.

American National Standards Institute, Inc.

Batterymarch Park New York, NY 10018

National Fire Protection Association, Inc.

1430 Broadway Quincy, MA 02269

PRODUCT FEATURES OPERATION

This heater is clean burning. It requires no outside venting. There is no heat loss out a vent or up a chimney. Heat is generated by both realistic flames and glowing coals. This heater is designed for vent-free operation with flue damper closed. It has been tested and ap- proved to ANS Z21.11.2 standard for unvented heaters. State and local codes in some areas prohibit the use of vent-free heat- ers. This heater may also be operated as a vented decorative (ANS Z21.60) product by opening the flue damper (non-thermostat operation only).

PRODUCT IDENTIFICATION

SAFETY PILOT

This heater has a pilot with an Oxygen Depletion Sensing(ODS) safety shutoff sys- tem. The ODS/pilot is a required feature for vent-free room heaters. The ODS/pilot shuts off the heater if there is not enough fresh air.

PIEZO IGNITION SYSTEM

This heater has a piezo ignitor. This system requires no matches, batteries, or other sources to light heater.

Figure 1 - Ember Master

Show 14 more labels / short text on this page
Top Middle Log · Crossover Log · Rear Log · Front Logs · Rear Burner · Front Burner · Bottom Middle Log · Piezo Ignitor · Control Knob · Flame Adjustment Knob · Base Assembly · Selector Switch (Optional) · Continued · 3 105073
Page 4 of the FMI VFP18R user manual — AIR FOR COMBUSTION AND VENTILATION
Page 4 · click to enlarge
Page 4

PRODUCT FEATURES Continued

PROVIDING ADEQUATE VENTILATION

Confined and Unconfined Space

The National Fuel Gas Code, ANS Z223.1 defines a confined space as a space whose volume is less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggre- gate input rating of all appliances installed in that space and an unconfined space as a space whose volume is not less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space. Rooms communicating directly with the space in which the appliances are installed*, through openings not furnished with doors, are con- sidered a part of the unconfined space.

The following are excerpts from National Fuel Gas Code, NFPA 54/ANS Z223.1, Sec- tion 5.3, Air for Combustion and Ventilation.

OPTIONAL REMOTE CONTROL ACCESSORIES

All spaces in homes fall into one of the three following ventilation classifications: 1. Unusually Tight Construction 2. Unconfined Space 3. Confined Space

  • There are four optional remote controls that can be purchased separately for this log heater:
  • wall switch
  • wall thermostat
  • hand-held ON/OFF remote
  • hand-held thermostat remote

The information on pages 4 through 6 will help you classify your space and provide adequate ventilation.

See Accessories, page 24.

Unusually Tight Construction

This heater shall not be installed in a con- fined space or unusually tight construction unless provisions are provided for adequate combustion and ventilation air.

The wall thermostat or hand-held thermo- stat control may not be used where vented decorative listing is required.

The air that leaks around doors and win- dows may provide enough fresh air for combustion and ventilation. However, in buildings of unusually tight construction, you must provide additional fresh air.

AIR FOR COMBUSTION AND VENTILATION

* Adjoining rooms are communicating only if there are doorless passageways or ventila- tion grills between them.

Unusually tight construction is de- fined as construction where: a. walls and ceilings exposed to the outside atmosphere have a con- tinuous water vapor retarder with a rating of one perm (6 x 10-11 kg per pa-sec-m2) or less with open- ings gasketed or sealed and b. weather stripping has been added on openable windows and doors and c. caulking or sealants are applied to areas such as joints around window and door frames, be- tween sole plates and floors, be- tween wall-ceiling joints, be- tween wall panels, at penetra- tions for plumbing, electrical, and gas lines, and at other openings.

Today’s homes are built more energy effi- cient than ever. New materials, increased insulation, and new construction methods help reduce heat loss in homes. Home owners weather strip and caulk around windows and doors to keep the cold air out and the warm air in. During heating months, home owners want their homes as airtight as possible.

If your home meets all of the three criteria above, you must provide ad- ditional fresh air. See Ventilation Air From Outdoors, page 6.

While it is good to make your home energy efficient, your home needs to breathe. Fresh air must enter your home. All fuel-burning appliances need fresh air for proper com- bustion and ventilation.

If your home does not meet all of the three criteria above, proceed to Deter- mining Fresh-Air Flow for Heater Lo- cation, page 5.

Exhaust fans, fireplaces, clothes dryers, and fuel burning appliances draw air from the house to operate. You must provide ad- equate fresh air for these appliances. This will insure proper venting of vented fuel- burning appliances.

4 105073

Page 5 of the FMI VFP18R user manual — DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION
Page 5 · click to enlarge
Page 5

AIR FOR COMBUSTION AND VENTILATION Continued

DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION

Determining if You Have a Confined or Unconfined Space

Use this work sheet to determine if you have a confined or unconfined space.

Space: Includes the room in which you will install heater plus any adjoining rooms with doorless passageways or ventilation grills between the rooms. 1. Determine the volume of the space (length x width x height). Length x Width x Height = cu. ft. (volume of space) Example: Space size 20 ft. (length) x 16 ft. (width) x 8 ft. (ceiling height) = 2560 cu. ft. (volume of space) If additional ventilation to adjoining room is supplied with grills or openings, add the volume of these rooms to the total volume of the space. 2. Divide the space volume by 50 cubic feet to determine the maximum Btu/Hr the space can support.

(volume of space) ÷ 50 cu. ft. = (Maximum Btu/Hr the space can support) Example: 2560 cu. ft. (volume of space) ÷ 50 cu. ft. = 51.2 or 51,200 (maximum Btu/Hr the space can support) 3. Add the Btu/Hr of all fuel burning appliances in the space. Vent-free heater Btu/Hr Gas water heater* Btu/Hr Gas furnace Btu/Hr Vented gas heater Btu/Hr Gas fireplace logs Btu/Hr Other gas appliances* + Btu/Hr Total = Btu/Hr * Do not include direct-vent gas appliances. Direct-vent draws combustion air from the outdoors and vents to the outdoors. 4. Compare the maximum Btu/Hr the space can support with the actual amount of Btu/Hr used.

ExampleGas water heater 40,000 Btu/Hr Vent-free heater + 33,000 Btu/Hr Total = 73,000 Btu/Hr

Btu/Hr (maximum the space can support) Btu/Hr (actual amount of Btu/Hr used) Example: 51,200 Btu/Hr (maximum the space can support)

73,000 Btu/Hr (actual amount of Btu/Hr used)

The space in the above example is a confined space because the actual Btu/Hr used is more than the maximum Btu/Hr the space can support. You must provide additional fresh air. Your options are as follows: A. Rework worksheet, adding the space of an adjoining room. If the extra space provides an unconfined space, remove door to adjoin- ing room or add ventilation grills between rooms. See Ventilation Air From Inside Building, page 6. B. Vent room directly to the outdoors. See Ventilation Air From Outdoors, page 6. C. Install a lower Btu/Hr heater, if lower Btu/Hr size makes room unconfined.

If the actual Btu/Hr used is less than the maximum Btu/Hr the space can support, the space is an unconfined space. You will need no additional fresh air ventilation.

Continued · 5 105073

Page 6 of the FMI VFP18R user manual — Ventilation Air From Outdoors
Page 6 · click to enlarge
Page 6
FMI VFP18R — Ventilation Air From Outdoors diagram (page 6)
Fig. 1 · Ventilation Air From Outdoors

This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must pro- vide two permanent openings: one within 12" of the ceiling and one within 12" of the floor on the wall connecting the two spaces (see options 1 and 2, Figure 2). You can also remove door into adjoining room (see op- tion 3, Figure 2). Follow the National Fuel Gas Code, NFPA 54/ANS Z223.1, Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts.

Figure 2 - Ventilation Air from Inside Building

FMI VFP18R — Ventilation Air From Outdoors diagram (page 6)
Fig. 2 · Ventilation Air From Outdoors

Ventilation Air From Outdoors

Provide extra fresh air by using ventilation grills or ducts. You must provide two per- manent openings: one within 12" of the ceiling and one within 12" of the floor. Connect these items directly to the outdoors or spaces open to the outdoors. These spaces include attics and crawl spaces. Follow the National Fuel Gas Code, NFPA 54/ANS Z223.1, Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts.

Figure 3 - Ventilation Air from Outdoors

Outlet Air · 6 105073

Page 7 of the FMI VFP18R user manual — INCHES
Page 7 · click to enlarge
Page 7

INSTALLATION

LOG SIZING REQUIREMENTS Log SizeMinimum Firebox Size HeightDepthFront WidthRear* Width 18" 24" 30"17" 17" 17"14" 14" 14"20" 26" 32"14" 18" 22"
  • WARNING: Never install the heater
  • in a bedroom or bathroom unless installed as vented appliance, see page 10
  • in a recreational vehicle
  • where curtains, furniture, clothing, or other flammable objects are less than 42 inches from the front, top, or sides of the heater
  • in high traffic areas
  • in windy or drafty areas

NOTICE: This heater is intended for use as supplemental heat. Use this heater along with your pri- mary heating system. Do not in- stall this heater as your primary heat source. If you have a central heating system, you may run system’s circulating blower while using heater. This will help circu- late the heat throughout the house. In the event of a power outage, you can use this heater as your primary heat source.

*Measured at 14” depth

Carefully follow the instructions below. This will ensure safe installation into a masonry, UL127-listed manufactured fireplace, or listed vent-free firebox.

Minimum Clearances For Side Combustible Material, Side Wall, and Ceiling A. Clearances from the side of the fire- place cabinet to any combustible ma- terial and wall should follow the dia- gram in Figure 4. Example: The face of a mantel, book- shelf, etc. is made of combustible ma- terial and protrudes 3 1/2" from the wall. This combustible material must be 4" from the side of the fireplace opening (see Figure 4). Note: When installing your gas logs into a manufactured firebox, follow firebox manufacturer’s instructions for minimum clearances to combustible materials. B. Clearances from the top of the fireplace opening to the ceiling should not be less than 42 inches.

CHECK GAS TYPE Use only propane/LP gas. If your gas sup- ply is not propane/LP gas, do not install heater. Call dealer where you bought heater for proper type heater.

INSTALLATION AND CLEARANCES

121/4

(Vent-Free Operation Only)

101/2

7 8 3/4

51/4

INCHES

31/2

13/4

1 4 6 8 10 12 14 16 FIREBOX

MINIMUM FIREPLACE CLEARANCE TO COMBUSTIBLE MATERIALS Log Size 18", 24", 30”Side Wall 16"Ceiling 42"Floor* 5"

INCHES

*Minimum 16 inches from Side Wall

Figure 4 - Minimum Clearance for Combustible to Wall

*See Floor Clearances, page 9.

Show 6 more labels / short text on this page
Example · 7/8 · 7/16 · * · Continued · 7 105073
Page 8 of the FMI VFP18R user manual — Minimum Noncombustible Material Clearances
Page 8 · click to enlarge
Page 8

INSTALLATION Continued

You must have noncombustible material(s) above the fireplace opening. Noncombus- tible materials (such as slate, marble, tile, etc.) must be at least 1/2 inch thick. With sheet metal, you must have noncombustible material behind it. Noncombustible mate- rial must extend at least 8 inches up. If noncombustible material is less than 12", you must install the fireplace hood acces- sory. Even if noncombustible material is more than 12", you may need the hood accessory to deflect heat away from your mantel shelf. See Figure 5 and Figures 6 and 7, page 9 for minimum clearances.

Minimum Noncombustible Material Clearances

Noncombustible Material Distance (A)Requirements for Safe Installation 12" or more Between 8" and 12" Less than 8"Noncombustible material OK. Install fireplace hood accessory (HDABK or HDABR, see Accessories, page 24). 18" model: Noncombustible material OK. Noncombustible material must be extended to at least 8". See Between 8" and 12", above. If you cannot extend material, you must operate heater with flue damper open. Heat Resistant Material (A) Figure 5 - Heat Resistant Material (Slate, Marble, Tile, etc.) Above Fireplace

If Not Using Mantel

You must have noncombustible material(s) above the fireplace opening. Noncombus- tible materials (such as slate, marble, tile, etc.) must be at least 1/2 inch thick. With sheet metal, you must have noncombustible material behind it. Noncombustible material must extend at least 8" up (for all models). If noncombustible material is less than 12", you must install the fireplace hood accessory. See Figure 5 for minimum clearances.

If Using Mantel · 8 105073

Page 9 of the FMI VFP18R user manual — Determining Minimum Mantel Clearance When Using a Hood
Page 9 · click to enlarge
Page 9

INSTALLATION Continued

Underside of Mantel Shelf

MANTEL CLEARANCES

2 1/2"

In addition to meeting noncombustible mate- rial clearances, you must also meet required clearances between fireplace opening and mantel shelf. If you do not meet clearances listed in Figure 6 you will need a hood.

All minimum distances are in inches

(A)

Determining Minimum Mantel Clearance

Log Set 24" Models

24" & 30" Models

16 3/4"

18 1/2"

If you meet minimum clearance between mantel shelf and top of fireplace opening, a hood is not required (see Figure 6).

Top of Fireplace Opening

Minimum Non- Combustible Material Height

Distances to Underside of Mantel

Determining Minimum Mantel Clearance When Using a Hood

If minimum clearances in Figure 6 are not met, you must have a hood. When using a hood there are still certain minimum mantel clear- ances required. Follow minimum clearances shown in Figure 7, page 9 when using hood.

Figure 6 - Minimum Mantel Clearances Without Using Hood

Underside of Mantel Shelf

2 1/2"

All minimum distances are in inches

Minimum Non- Combustible Material 8" Min.

18" & 24" Models 20"

Top of Fireplace Opening

  • NOTICE: If your installation does not meet the minimum clearances shown, you must do one of the following:
  • operate the logs only with the flue damper open
  • raise the mantel to an acceptable height
  • remove the mantel

Distances to Underside of Mantel

Figure 7 - Minimum Mantel Clearances When Using Hood

FLOOR CLEARANCES A. If installing appliance on the floor level, you must maintain the minimum dis- tance of 14" to combustibles (see Fig- ure 8). B. If combustible materials are less than 14" to the fireplace, you must install appliance at least 5" above the combus- tible flooring (see Figure 9).

14" Min.

Hearth Combustible Material 5" Min.

14" Min.

5" Min.

Figure 8 - Minimum Fireplace Clearances If Installed at Floor Level

Figure 9 - Minimum Fireplace Clearances Above Combustible Flooring

Show 30 more labels / short text on this page
Mantel Shelf · 10" · 8" · 6" · Minimum Non- Combustible Material · 12" · 18" · 20" · 22" · 24" · 8" · 14" · 20" · 18" Model · 12" · 10" · 8" · 6" · Log Sets · 12" 15" 18" · All Models · Hood (HDABK,HDABR) · Combustible Material · Combustible Material · Hearth · Combustible Material · Non-Combustible Material · Noncombustible Material · Continued · 9 105073
Page 10 of the FMI VFP18R user manual — INSTALLING HEATER BASE ASSEMBLY
Page 10 · click to enlarge
Page 10
FMI VFP18R — INSTALLING HEATER BASE ASSEMBLY diagram (page 10)
Fig. 3

Masonry Fireplace Figure 10 - Attaching Damper Clamp

If your heater is a manually-controlled model, you may use this heater as a vented product. There are three reasons for operat- ing your heater in the vented mode. 1. The fireplace does not meet the clear- ance to combustibles requirements for vent-free operation. 2. State or local codes do not permit vent- free operation. 3. You prefer vented operation.

INSTALLING HEATER BASE ASSEMBLY

Note: Install optional FHRC or FHRCT Receiver and Hand-Held Remote Control Kit (see Accessories, page 24) before in- stalling gas log heater. See installation in- structions included with the kit. 1. Apply pipe joint sealant lightly to male threads of gas fitting. Connect approved flexible gas hose to inlet side of gas control (see Figure 11). 2. Locate two masonry screws in the hard- ware package. 3. Position heater base assembly in fireplace. 4. Place logs in their proper position on heater base. 5. Center heater base and logs, front-to- back and side-to-side in fireplace. 6. Carefully remove logs without moving heater base. 7. Mark screw locations through holes in front panel of base (see Figure 12, page 11). If installing in a brick-bottom fire- place, mark screw locations in mortar joint of bricks. 8. Remove heater base from fireplace. 9. Drill holes at marked locations using 3/16" masonary drill bit. 10. Attach base to fireplace floor using masonry screws (in hardware package).

If reasons number 1 or 2 above apply to you, you must permanently open chimney flue damper. You must install the damper clamp accessory (to order, see Accessories, page 24). This will insure vented operation (see Figure 10). The damper clamp will keep damper open. Installation instructions are included with clamp accessory.

See chart below for minimum permanent flue opening you must provide. Attach damper clamp so the minimum permanent flue opening will be maintained at all times.

Area of Various Standard Round Flues Diameter (ins.)Area (sq. ins.) 5" 6" 7" 8"20 sq. inches 29 sq. inches 39 sq. inches 51 sq. inches
FMI VFP18R — INSTALLING HEATER BASE ASSEMBLY diagram (page 10)
Fig. 4
Chimney Height (ft.)Minimum Permanent Flue Opening (sq. ins.) 6' to 15' 15' to 30'39 sq. inches 29 sq. inches
FMI VFP18R — INSTALLING HEATER BASE ASSEMBLY diagram (page 10)
Fig. 5
  • Installation Items Needed
  • hardware package (provided with heater)
  • approved flexible gas hose (not provided) (if allowed by local codes)
  • sealant (resistant to propane/LP gas, not provided)
  • electric drill with 3/16" drill bit

Figure 11 - Attaching Flexible Gas Hose to Heater Gas Regulator

10 105073

Page 11 of the FMI VFP18R user manual — Installation Items Needed
Page 11 · click to enlarge
Page 11

INSTALLATION Continued

The installer must supply an external regu- lator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11 and 14 inches of water. If you do not reduce incom- ing gas pressure, heater regulator damage could occur. Install external regulator with the vent pointing down as shown in Figure 13. Pointing the vent down protects it from freezing rain or sleet.

Installation must include an equipment shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from heater (see Figure 14).

Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged heater valves.

CAUTION: Use only new, black iron or steel pipe. Inter- nally-tinned copper tubing may be used in certain areas. Check your local codes. Use pipe of 1/2" diameter or greater to allow proper gas volume to heater. If pipe is too small, undue loss of pressure will occur. WARNING: This appliance re- quires a 1/2" NPT (National Pipe Thread) inlet connection to the pressure regulator. Propane/ LP Supply Tank External Regulator

Figure 12 - Attaching Base Assembly to Fireplace Floor

We recommend that you install a sediment trap in supply line as shown in Figure 14. Locate sediment trap where it is within reach for cleaning. Install in piping system between fuel supply and heater. Locate sedi- ment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into heater controls. If sediment trap is not installed or is installed wrong, heater may not run properly.

CONNECTING TO GAS SUPPLY

Figure 13 - External Regulator With Vent Pointing Down

Installation Items Needed

CSA/AGA Design-Certified Equipment Shutoff Valve With 1/8" NPT Tap

From External Regulator (11" W.C.* to 14" W.C. Pressure)

  • Before installing heater, make sure you have the items listed below.
  • external regulator (supplied by installer, see Figure 13)
  • piping (check local codes)
  • sealant (resistant to propane/LP gas)
  • equipment shutoff valve *
  • test gauge connection *
  • sediment trap
  • tee joint
  • pipe wrench

Approved Flexible Gas Hose (if allowed by local codes)

Tee Joint Pipe Nipple Cap

* An CSA/AGA design-certified equipment shutoff valve with 1/8" NPT tap is an accept- able alternative to test gauge connection.

Figure 14 - Gas Connection

* Minimum inlet pressure for purpose of input adjustment.

Show 7 more labels / short text on this page
Masonry Screw · Vent Pointing Down · Gas Control · 3" Minimum · Sediment Trap · Continued · 11 105073
Page 12 of the FMI VFP18R user manual — O POS
Page 12 · click to enlarge
Page 12

INSTALLATION Continued

Test Pressures Equ al To or Less Than 1/2 PSIG (3.5 kPa) 1. Close equipment shutoff valve (see Fig- ure 15). 2. Pressurize supply piping system by ei- ther using compressed air or opening propane/LP supply tank valve. 3. Check all joints from propane/LP sup- ply tank to equipment shutoff valve (see Figure 16). Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak. 4. Correct all leaks at once.

Pressure Testing Heater Gas Connections 1. Open equipment shutoff valve (see Fig- ure 15). 2. Open propane/LP supply tank valve. 3. Make sure control knob of heater is in the OFF position. 4. Check all joints from equipment shutoff valve to gas control (see Figure 15). Apply mixture of liquid soap and wa- ter to gas joints. Bubbles forming show a leak. 5. Correct all leaks at once. 6. Light heater (see Operating Heater, pages 14 through 16). Check all other internal joints for leaks. 7. Turn off heater (see To Turn Off Gas to Appliance, page 15).

CHECKING GAS CONNECTIONS

ON POSITI

O POS

Figure 15 - Equipment Shutoff Valve

Equipment Shutoff Valve Pressure Testing gas Supply Piping system

Test Pressures In Excess Of 1/2 PSIG (3.5 kPa) 1. Disconnect appliance with its appliance main gas valve (control valve) and equip- ment shutoff valve from gas supply pip- ing system. Pressures in excess of 1/2 psig will damage heater regulator. 2. Cap off open end of gas pipe where equipment shutoff valve was con- nected. 3. Pressurize supply piping system by ei- ther using compressed air or opening propane/LP supply tank valve. 4. Check all joints of gas supply piping system. Apply mixture of liquid soap and water to gas joints. Bubbles form- ing show a leak. 5. Correct all leaks at once. 6. Reconnect heater and equipment shutoff valve to gas supply. Check re- connected fittings for leaks.

Figure 16 - Checking Gas Joints

Show 6 more labels / short text on this page
Open · Equipment Shutoff Valve · Closed · Propane/LP Supply Tank · Control Valve Location · 12 105073
Page 13 of the FMI VFP18R user manual — INSTALLING LOGS
Page 13 · click to enlarge
Page 13

Rear Log (#3) Peg

INSTALLATION Continued

Groove in Back of Log

Groove in Back of Log

INSTALLING LOGS

Each log is marked with a number. These numbers will help you identify the log when installing. It is very important to install these logs exactly as instructed. Do not modify logs. Only use logs supplied with heater. 1. Place front logs (#1L and #1R) on top of the grate. Make sure the notches in the bottom of the logs fit over the grate prongs (see Figure 17). Push back of logs flush with metal grate bar. Note: 18" model has only one front log. 2. Rest bottom middle log (#2) behind metal posts on front burner. Make sure the grooves in the bottom of the log fit over the grate. Bring the log forward next to the metal posts. The pegs on the log must be on top (see Figure 18). 3. Slide the grooves in the back of the rear log (#3) against the rear grate prongs. Make sure the peg on the log is on top (see Figure 19). 4. Place the top middle log (#4) on the bottom middle log (#2). Make sure the pegs of the bottom middle log fit se- curely in the holes of the top middle log (see Figure 20). 5. Place the crossover log (#5) on the back log and the top middle log. Make sure the peg on the rear log is in the hole in the bottom of the crossover log. The crossover log should fit in the cutout of the top middle log (see Figure 21).

Figure 17 - Installing Front Log (#1)

Figure 19 - Installing Rear Log (#3)

Bottom Middle Log (#2)

Top Middle Log (#4) Hole

Figure 18 - Installing Bottom Middle Log (#2)

Figure 20 - Installing Crossover Log (#4)

Figure 21 - Installing Crossover Log (#5)

Show 16 more labels / short text on this page
Front Log (#1) · Notch · Grate Prong · Grate Prong · Grate Prongs · Metal Grate Bar · Groove · Groove · Peg · Metal Post · Metal Post · Grate · Crossover Log (#5) · Hole · Peg Cutout · 13 105073
Page 14 of the FMI VFP18R user manual — O
Page 14 · click to enlarge
Page 14

LIGHTING INSTRUCTIONS

1. STOP! Read the safety information, column 1. 2. Make sure equipment shutoff valve is fully open. 3. Set selector switch in the OFF position.

OPERATING HEATER

FOR YOUR SAFETY

  • WARNING
  • If fireplace has glass doors, never operate this heater with glass doors closed. If you operate heater with doors closed, heat buildup inside fireplace will cause glass to burst. Also if fireplace opening has vents at the bottom, you must open the vents before operating heater.
  • You must operate this heater with a fireplace screen in place. Make sure fireplace screen is closed before running heater.

READ BEFORE

LIGHTING

4. Press in and turn control knob clock- wise to the OFF position (see Figure 22). 5. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety in- formation above. If you don’t smell gas, go to the next step. 6. Press in and turn control knob coun- terclockwise to the PILOT position. Press in control knob for five (5) seconds (see Figure 22). Note: You may be running this heater for the first time after hook- ing up to gas supply. If so, the con- trol knob may need to be pressed in for 30 seconds or less. This will allow air to bleed from the gas system. 7. With control knob pressed in, press and release ignitor button. This will light pilot. The pilot is attached to the front burner. If needed, keep press- ing ignitor button until pilot lights. Note: If pilot does not stay lit, con- tact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Light- ing Procedure, page 15.

  • A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly. B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor. WHAT TO DO IF YOU SMELL GAS
  • Do not try to light any appliance.
  • Do not touch any electric switch; do not use any phone in your building.
  • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
  • If you cannot reach your gas supplier, call the fire department. C. Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service technician or gas supplier. Force or attempted repair may result in a fire or explosion. D. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

Note: Home owners generally prefer to operate their heater with the chimney damper closed. This will put all the heat into the room. However, there may be times you will desire the full flames of the Hi heat setting but will find the heat output excessive. You can open the chim- ney damper (if you have one) fully or partially to release some of the heat.

O

T

O

P

O

F

N

O

F

H

AUTO OFF ON

Ignitor Button Selector Switch in OFF Position Flame Adjustment Knob

Figure 22 - Control Knob and Ignitor Button Location

Control Knob · 14 105073

Page 15 of the FMI VFP18R user manual — Thermostat Control Operation
Page 15 · click to enlarge
Page 15

OPERATING HEATER Continued

TO TURN OFF GAS TO

For wall thermostat operation, follow in- struction supplied with thermostat ac- cessory GWMT1. For wall switch opera- tion follow instructions supplied with GWMS2.

APPLIANCE

Shutting Off Heater 1. Turn control knob clockwise to the OFF position. 2a. Set selector switch in the OFF position. 2b. If Using Optional Hand-Held Re- mote: Set selector switch in the OFF position to prevent draining battery.

8. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. • If control knob does not pop out when released, contact a qualified service person or gas supplier for repairs. Note: If pilot goes out, repeat steps 4 through 8.

1. After lighting, let pilot flame burn for about one minute. Turn control knob to ON position. Adjust flame adjust- ment knob anywhere between HI and LO. Slide the selector switch to the REMOTE position. Note: The burn- ers may light if hand-held remote ON button was on when selector switch was last turned off. You can now turn the burners on and off with the hand- held remote control unit. IMPORTANT: Do not leave the se- lector switch in the REMOTE or ON position when the pilot is not lit. This will drain the battery. IMPORTANT: Be sure to press the ON/ OFF buttons on the hand-held remote control unit for up to 3 seconds to as- sure proper operation

Shutting Off Burners Only (pilot stays lit)

9. Slightly push in and turn control knob counterclockwise to the ON position. 10. Wait one minute and switch selector switch to the ON position to light burner. Note: AUTO is only functional when using GWMT1 or GWMS2 optional accessories. 11. Set flame adjustment knob to any level between HI and LO.

You may shut off the burners and keep the pilot lit by doing one of the following: 1. Turn control knob clockwise to the PILOT position. 2. Use remote control manual OFF button. 3. Set selector switch in the OFF position.

MANUAL LIGHTING

PROCEDURE

1. Follow steps 1 through 6 under Lighting Instructions , page 14. 2. Depress control knob and light pilot with match. 3. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Now follow steps 9 through 11, Lighting Instructions, column 1.

GHRC Series Operation: 2a. Press ON/OFF button to turn the burner on and off. When turning burner off, the pilot will remain lit.

  • GHRCTA Series Operation: 2b. Press the AUTO/ON/OFF button on the hand-held remote control (see Figure 25, page 16). The lights to the left of the button will show AUTO, ON, or OFF.
  • In the ON mode, the burners will ignite. The heater is in manual mode when ON is lit.
  • In the AUTO mode, the thermostat in the hand-held remote unit controls the room temperature. To increase the room temperature, press the top arrow of the TEMP button. To lower the room temperature, press the bottom arrow of the TEMP button. At higher settings the heater will run longer.

OPTIONAL REMOTE

Ignitor Electrode Pilot Burner

OPERATION

Thermostat Control Operation

(Optional GHRCTA Series Only) The thermostat control setting on the remote control unit can be set to any comfort level between WARMER and COOLER. The burners will turn on and off auto- matically to maintain the comfort level you select. The ideal comfort setting will vary by household depending upon the amount of space to be heated, the output of the central heating system, etc.

Figure 23 - Pilot

Continued · 15 105073

Page 16 of the FMI VFP18R user manual — FRONT BURNER FLAME PATTERN
Page 16 · click to enlarge
Page 16

OPERATING HEATER Continued

INSPECTING BURNERS Check pilot flame pattern and burner flame patterns often.

FMI VFP18R — OPERATING HEATER Continued diagram (page 16)
Fig. 6 · OPERATING HEATER Continued

IMPORTANT: This remote control has been specially engineered to take an air temperature sample every 5.5 minutes in the auto mode. It will not respond immediately to the tempera- ture setting being turned up or down. IMPORTANT: The hand-held remote control unit must be near the heater. Do not keep the hand-held remote control unit too close to the heater. The thermostat on the hand-held re- mote control unit will heat up too quickly and turn the heater off. 3. To turn the burner off, press the AUTO/ON/OFF button until OFF lights. The pilot will remain lit. IMPORTANT: To turn the pilot off, manually turn the control knob on the heater to the OFF position.

PILOT FLAME PATTERN

Figure 26 shows a correct pilot flame pat- tern. Figure 27 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching the thermocouple. This will cause the thermocouple to cool. When the thermocouple cools, the heater will shut down.

  • If pilot flame pattern is incorrect, as shown in Figure 27
  • turn heater off (see To Turn Off Gas to Appliance , page 15)
  • see Troubleshooting , pages 18 through 20

FRONT BURNER FLAME PATTERN

Figure 28, page 17, shows correct front burner flame pattern. Figure 29, page 17, shows incorrect front burner flame pattern. The incorrect burner flame pattern shows yellow tipping at top of blue flame.

FMI VFP18R — FRONT BURNER FLAME PATTERN diagram (page 16)
Fig. 7

Control Knob in On Position

FMI VFP18R — FRONT BURNER FLAME PATTERN diagram (page 16)
Fig. 8

Selector Switch in Remote Position

Figure 24 - Setting the Remote Selector Switch, Control Knob, and Flame Adjustment Knob for Remote Operation

FMI VFP18R — FRONT BURNER FLAME PATTERN diagram (page 16)
Fig. 9
  • If front burner flame pattern is incorrect, as shown in Figure 29, page 17.
  • turn heater off (see To Turn Off Gas to Appliance , page 15)
  • see Troubleshooting , pages 18 through 20

The Log Heater will Automatically Cycle between Pilot and the Heat Setting that has been Selected

Turns Burners On or Off and Allows You to Choose the Auto Setting

Figure 24 - Thermostat Hand-Held Remote Control Unit Selections (GHRCTA Series Only)

Show 4 more labels / short text on this page
Pilot Burner · Thermocouple · Thermocouple · Flame Adjustment Knob
Page 17 of the FMI VFP18R user manual — CLEANING BURNERS INJECTOR HOLDER AND PILOT AIR INLET HOLE
Page 17 · click to enlarge
Page 17

INSPECTING BURNERS Continued

We also recommend that you keep the burner tube and pilot assembly clean and free of dust and dirt. To clean these parts we recom- mend using compressed air no greater than 30 PSI. Your local computer store, hard- ware store, or home center may carry com- pressed air in a can. You can use a vacuum cleaner in the blow position. If using com- pressed air in a can, please follow the direc- tions on the can. If you don't follow direc- tions on the can, you could damage the pilot assembly. 1. Shut off the unit, including the pilot. Allow the unit to cool for at least thirty minutes. 2. Inspect burners, pilot, and primary air inlet holes on injector holder for dust and dirt (see Figure 30). 3. Blow air through the ports/slots and holes in the burners. 4. Check the injector holder located at the end of the burner tube again. Remove any large particles of dust, dirt, lint, or pet hair with a soft cloth or vacuum cleaner nozzle. 5. Blow air into the primary air holes on the injector holder. 6. In case any large clumps of dust have now been pushed into the burner repeat steps 3 and 4.

Figure 28 - Correct Front Burner Flame Pattern

Pilot Air Inlet Hole

Yellow Tipping At Top of Blue Flame

Figure 29 - Incorrect Front Burner Flame Pattern

Figure 31 - Pilot Inlet Air Hole

CLEANING AND MAINTENANCE

  • LOGS
  • If you remove logs for cleaning, refer to Installing Logs, page 13, to properly replace logs.
  • Replace log(s) if broken or chipped (dime-sized or larger).

Clean the pilot assembly also. A yellow tip on the pilot flame indicates dust and dirt in the pilot assembly. There is a small pilot air inlet hole about two inches from where the pilot flame comes out of the pilot assembly (see Figure 31). With the unit off, lightly blow air through the air inlet hole. You may blow through a drinking straw if compressed air is not available.

CLEANING BURNERS INJECTOR HOLDER AND PILOT AIR INLET HOLE

The primary air inlet holes allow the proper amount of air to mix with the gas. This pro- vides a clean burning flame. Keep these holes clear of dust, dirt, lint, and pet hair. Clean these air inlet holes prior to each heating season. Blocked air holes will create soot. We recommend that you clean the unit every three months during operation and have heater in- spected yearly by a qualified service person.

Primary Air Inlet Holes

Figure 30 - Injector Holder On Outlet Burner Tube

Show 7 more labels / short text on this page
Ports/Slots · Burner Tube · Pilot Assembly · Injector Holder · Ports/Slots · Burner Tube · 17 105073
Page 18 of the FMI VFP18R user manual — OBSERVED PROBLEM
Page 18 · click to enlarge
Page 18

TROUBLESHOOTING

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

When ignitor button is pressed, there is no spark at ODS/pilot

1. Ignitor electrode not connected to ignitor cable 2. Ignitor cable pinched or wet
1. Reconnect ignitor cable
2. Free ignitor cable if pinched by any metal or tubing. Keep ignitor cable dry 3. Tighten nut holding piezo ignitor to base panel of log set. Nut is located behind base panel 4. Replace ignitor cable 5. Replace piezo ignitor 6. Replace ignitor 7. Replace ignitor
3. Piezo ignitor nut is loose
4. Broken ignitor cable 5. Bad piezo ignitor 6. Ignitor electrode positioned wrong 7. Ignitor electrode broken

When ignitor button is pressed, there is spark at ODS/pilot but no ignition

1. Gas supply turned off or equipment shutoff valve closed 2. Control knob not in PILOT position 3. Control knob not pressed in while in PILOT position 4. Air in gas lines when installed
1. Turn on gas supply or open equipment shutoff valve 2. Turn control knob to PILOT position 3. Press in control knob while in PILOT position 4. Continue holding down control knob. Repeat igniting operation until air is removed 5. Contact local propane/LP gas company 6. Clean ODS/pilot (see Cleaning and Maintenance , page 17) or replace ODS/ pilot assembly 7. Replace gas control
5. Depleted gas supply 6. ODS/pilot is clogged
7. Gas control setting is not correct

ODS/pilot lights but flame goes out when control knob is released

1. Control knob not fully pressed in 2. Control knob not pressed in long enough
1. Press in control knob fully 2. After ODS/pilot lights, keep control knob pressed in 30 seconds 3. Fully open equipment shutoff valve 4. A) Contact local propane/LP gas company B) Clean ODS/pilot (see Cleaning and Maintenance , page 17) or replace ODS/ pilot assembly
3. Equipment shutoff valve not fully open 4. Pilot flame not touching thermocouple, which allows thermocouple to cool, causing pilot flame to go out. This problem could be caused by one or both of the following: A) Low gas pressure B) Dirty or partially clogged ODS/pilot 5. Thermocouple connection loose at control valve 6. Thermocouple damaged 7. Gas control damaged
5. Hand tighten until snug, then tighten 1/4 turn more 6. Replace thermocouple 7. Replace gas control

www.desatech.com

18 105073

Page 19 of the FMI VFP18R user manual — OBSERVED PROBLEM
Page 19 · click to enlarge
Page 19

TROUBLESHOOTING Continued

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

One or both burners do not light after ODS/ pilot is lit

1. Inlet gas pressure is too low 2. Burner orifice(s) clogged
1. Contact local propane/LP gas company 2. Clean burner(s) (see Cleaning and Maintenance , page 17) or replace burner orifice(s) 3. Contact qualified service person 4. Replace burner orifice(s) 5. Put selector switch in ON position 6. See Wiring Diagram, page 21
3. Mislocated crossover tube 4. Burner orifice(s) diameter is too small 5. Selector switch in OFF position 6. Wire disconnected from gas control

Delayed ignition of one or both burners

1. Manifold pressure is too low 2. Burner orifice(s) clogged
1. Contact local propane/LP gas company 2. Clean burner(s) (see Cleaning and Maintenance , page 17) or replace burner orifice(s) 3. Contact qualified service person
3. Mislocated crossover tube

Burner backfiring during combustion

1. Burner orifice is clogged or damaged
1. Clean burner (see Cleaning and Maintenance , page 17) or replace burner orifice 2. Replace damaged burner 3. Replace gas control
2. Damaged burner 3. Gas control defective

Yellow flame in front burner during burner combustion

1. Not enough air
1. Check burner(s) for dirt and debris. If found, clean burner(s) (see Cleaning and Maintenance , page 17) 2. Replace gas control
2. Gas control defective

Slight smoke or odor during initial operation

1. Residues from manufacturing processes and logs curing
1. Problem will stop after a few hours of operation

Moisture/condensation noticed on windows

1. Not enough combustion/ventilation air
1. Refer to Air for Combustion and Ventilation requirements (page 4)

Heater produces a whistling noise when burners are lit

1. Turning control knob to HI position when burners are cold 2. Air in gas line
1. Turn control knob to LO position and let warm up for a minute 2. Operate burners until air is removed from line. Have gas line checked by local Propane/LP gas company 3. Observe minimum installation clearances (see pages 7 through 9) 4. Clean burners (see Cleaning and Maintenance , page 17) or replace burner orifice(s)
3. Air passageways on heater blocked
4. Dirty or partially clogged burner orifice(s)

White powder residue forming within burner box or on adjacent walls or furniture

1. When heated, vapors from furniture polish, wax, carpet cleaners, etc. turn into white powder residue
1. Turn heater off when using furniture polish, wax, carpet cleaners, or similar products

Remote does not function (GHRC Series and GHRCT Series only)

1. Battery is not installed. Battery power is low
1. Replace 9-volt batteries in receiver and remote control

Continued www.desatech.com

19 105073

Page 20 of the FMI VFP18R user manual — OBSERVED PROBLEM
Page 20 · click to enlarge
Page 20

TROUBLESHOOTING Continued

  • WARNING: If you smell gas
  • Shut off gas supply.
  • Do not try to light any appliance.
  • Do not touch any electrical switch; do not use any phone in your building.
  • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
  • If you cannot reach your gas supplier, call the fire department.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Heater produces a clicking/ticking noise just after burners are lit or shut off

1. Metal expanding while heating or contracting while cooling
1. This is common with most heaters. If noise is excessive, contact qualified service person

Heater produces unwanted odors

1. Heater burning vapors from paint, hair spray, glues, cleaners, chemicals, new carpet, etc. (See IMPORTANT statement above) 2. Low fuel supply 3. Gas leak. See Warning statement above
1. Open window to ventilate room. Stop using odor causing products while heater is running
2. Refill supply tank 3. Locate and correct all leaks (see Checking Gas Connections , page 12)

Heater shuts off in use (ODS operates)

1. Not enough fresh air is available 2. Low line pressure 3. ODS/pilot is partially clogged
1. Open window and/or door for ventilation 2. Contact local propane/LP gas company 3. Clean ODS/pilot (see Cleaning and Maintenance , page 17)

Gas odor even when control knob is in OFF position

1. Gas leak. See Warning statement above 2. Gas control defective
1. Locate and correct all leaks (see Checking Gas Connections , page 12) 2. Replace gas control

Gas odor during combustion

1. Foreign matter between control valve and burner 2. Gas leak. See Warning statement above
1. Take apart gas tubing and remove foreign matter 2. Locate and correct all leaks (see Checking Gas Connections , page 12)

Log set cycles to pilot, but room tempera- ture drops to a lower than ideal level before log set comes back on (GHRCT Series only)

1. Hand-held remote control unit needs to be moved away from heater
1. Move hand-held remote control unit farther away from the heater

www.desatech.com

20 105073

Page 21 of the FMI VFP18R user manual — TECHNICAL SERVICE
Page 21 · click to enlarge
Page 21

SPECIFICATIONS

REPLACEMENT PARTS

18" Variable 24" Variable 30" Variable

Btu (Variable) 16,000/26,000 20,000/33,000 21,5000/36,000 Type Gas Propane/LP Only Propane/LP Only Propane/LP Only Ignition Piezo Piezo Piezo Manifold Pressure 7.9" W.C. 7.9" W.C. 7.9" W.C. Inlet Gas Pressure (in. of water)

PARTS UNDER WARRANTY

Contact authorized dealers of this product. If they can’t supply original replacement part(s), call Fireplace Manufacturers Incorporated’s Technical Service Depart- ment at 1-888-427-8322.

Maximum 14" 14" 14" Minimum* 11" 11" 11"

  • When calling Fireplace Manufacturers Incorporated, have ready
  • your name and address
  • model and serial numbers of your heater
  • how heater was malfunctioning
  • type of gas used (propane/LP or natural gas)
  • purchase date

Shipping Weight 32 lbs. 34 lbs. 36 lbs.

* For purpose of input adjustment

WIRING DIAGRAM

Usually, we will ask you to return the defec- tive part to the factory.

PARTS NOT UNDER WARRANTY

AUTO

OFF ON

Contact authorized dealers of this product. If they can’t supply original replacement part(s), call Fireplace Manufacturers Incorporated’s Parts Department at 1-800- 888-2050 for referral information.

  • When calling Fireplace Manufacturers Incorporated, have ready
  • model and serial numbers of your heater
  • the replacement part number

TECHNICAL SERVICE

SERVICE HINTS

  • When Gas Pressure Is Too Low
  • pilot will not stay lit
  • burners will have delayed ignition
  • heater will not produce specified heat
  • propane/LP gas supply may be low

You may have further questions about in- stallation, operation, or troubleshooting.

If so, contact DESA International’s Techni- cal Service Department at 1-800-DESA LOG (1-800-337-2564).

  • When Gas Quality Is Bad
  • pilot will not stay lit
  • burners will produce flames and soot
  • heater will backfire when lit

You can also visit DESA International’s technical services web site at www.desatech.com.

You may feel your gas pressure is too low or gas quality is bad. If so, contact your local propane/LP gas supplier.

Thermopile · 21 105073

Page 22 of the FMI VFP18R user manual — ILLUSTRATED PARTS BREAKDOWN
Page 22 · click to enlarge
Page 22

ILLUSTRATED PARTS BREAKDOWN

FMI VFP18R — ILLUSTRATED PARTS BREAKDOWN diagram (page 22)
Fig. 10

22 105073

Page 23 of the FMI VFP18R user manual — PARTS AVAILABLE — NOT SHOWN
Page 23 · click to enlarge
Page 23

PARTS LIST

This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 21 of this manual.

VFP18R VFP24R VFP30R

KEY PART NUMBERS NO. VFP18R VFP24R VFP30R DESCRIPTION QTY.

1L 105241-01 105241-02 105998-01 Left Front Log (#1L) 1 1R 105241-03 105999-01 Right Front Log (#1R) 1 2 105243-01 105243-02 106000-01 Bottom Middle Log (#2) 1 3 105245-01 105245-02 106001-01 Rear Log (#3) 1 4 105249-01 105249-02 106002-01 Top Middle Log (#4) 1 5 105247-01 105247-02 106003-01 Crossover Log (#5) 1 6 103778-01 103778-01 103778-01 O.D.S. Pilot 1 7 098249-01 098249-01 098249-01 Nut 6 8 103780-01 103780-01 103780-01 Pilot Bracket 1 9 101330-01 101330-05 101330-06 Front Burner Assembly 1 9-1 101008-01 101008-01 101008-01 Crossover Burner Gasket 1 9-2 101007-01 101007-01 101007-01 Crossover Burner 1 10 100999-02 100999-02 100999-03 Rear Burner Assembly 1 11 103984-01 103984-02 103984-03 Base Assembly and Decal 1 12 098271-06 098271-06 098271-06 Ignitor Cable 1 13 102445-01 102445-01 102445-01 Piezo Ignitor 1 14 103588-01 103588-01 103588-01 Heat Shield 1 15 103782-01 103782-01 103782-01 Valve Bracket 1 16 M12461-26 M12461-26 M12461-26 Screw 5 17 103781-02 103781-02 103781-02 Gas Control 1 18 098264-02 098264-02 098264-02 Male Fitting 1 19 103784-02 103784-02 103784-02 Flame Adjustment Knob 1 20 103784-01 103784-01 103784-01 Control Knob 1 21 103587-01CK 103587-01CK 103587-01CK Switch Plate 1 22 M11084-26 M11084-26 M11084-26 Screw 2 23 103284-02 103284-02 103284-02 Wiring Harness 1 24 099387-09 099387-09 099387-09 Pilot Tube 1 25 101004-10 101004-01 101004-02 Rear Burner Injector 1 26 101004-10 101004-02 101004-06 Front Burner injector 1 27 103783-01 103783-01 103783-01 Remote Burner Tube 1 28 099998-01 099998-01 099998-01 Switch 1 29 M11084-26 M11084-26 M11084-26 Screw 6

PARTS AVAILABLE — NOT SHOWN

100563-01 100563-01 100563-01 Warning Plate 1 103877-01 103877-01 103877-01 Lighting Instructions Plate 1 100565-01 100565-01 100565-01 Warning Plate Fastener 1 100639-01 100639-01 100639-01 Caution Decal 1 101137-02 101137-02 101137-02 Hardware Kit 1 GA6060 GA6060 GA6060 Lava Rock 1

23 105073

Page 24 of the FMI VFP18R user manual — LAVA ROCK - GA6060 (Not Shown)
Page 24 · click to enlarge
Page 24

ACCESSORIES

WALL-MOUNT THERMOSTAT SWITCH - GWMT1 (Not Shown)

WARMER

Purchase these heater accessories from your local dealer. If they can not supply these accessories, call Fireplace Manufacturers Incorporated’s Parts Department at 1-800- 888-2050 for referral information. You can also write to the address listed on the back page of this manual.

COOLER

TEMP

OFF

ON

AUTO

For all models. The desired comfort setting can be selected on the wall thermostat and the log heater will automatically cycle from pilot to the heat setting selected.

RECEIVER AND HAND-HELD THERMOSTAT REMOTE CONTROL KIT - GHRCT SERIES

WALL-MOUNT ON/OFF SWITCH - GWMS2 (Not Shown)

For all models. Allows the gas log heater to be turned on and off with a wall switch.

For all models. Allows the gas log heater to be operated in a manually or thermostati- cally-controlled mode. You can turn the gas log heater on and off without ever leaving the comfort of your easy chair.

DAMPER CLAMP - 02017 (Not Shown)

FIREPLACE HOOD Black - HDABK Brass - HDABR

Permanently opens chimney flue damper for vented operation. Can be used only with non-thermostat accessories.

For all models. Helps deflect heat away from mantel or wall above fireplace. Fits openings 28” and 49” wide.

LAVA ROCK - GA6060 (Not Shown)

RECEIVER AND HANDHELD REMOTE CONTROL KIT - GHRC SERIES

For all models. Order when additional rock is desired. (31/2 lb. bag)

For all models. Allows the gas log heater to be turned on and off by using a hand-held remote control.

24 105073

Page 25 of the FMI VFP18R user manual — NOTES
Page 25 · click to enlarge
Page 25

NOTES

Show 35 more labels / short text on this page
_______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · 25 105073
Page 26 of the FMI VFP18R user manual — INTERNATIONAL
Page 26 · click to enlarge
Page 26

KEEP THIS WARRANTY WARRANTY INFORMATION

Serial No.

Always specify model and serial numbers when communicating with the factory.

We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty. We make no other warranty, expressed or implied.

LIMITED WARRANTY VENT-FREE PROPANE/LP GAS LOG HEATERS

DESA International warrants this product to be free from defects in materials and components for one (1) year from the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions. To make a claim under this warranty the Bill of Sale or cancelled check must be presented.

This warranty is extended only to the original retail purchaser. This warranty covers the cost of part(s) required to restore this heater to proper operating condition and an allowance for labor when provided by a DESA International Authorized Service Center. Warranty part(s) MUST be obtained through authorized dealers of this product and/or DESA International who will provide original factory replacement parts. Failure to use original factory replacement parts voids this warranty. The heater MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit.

This warranty does not apply to parts that are not in original condition because of normal wear and tear, or parts that fail or become damaged as a result of misuse, accidents, lack of proper maintenance or defects caused by improper installation. Travel, diagnostic cost, labor, transportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner.

TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT; THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND LIMITS THE DURA- TION OF ANY AND ALL IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO ONE (1) YEAR ON ALL COMPONENTS AND FROM THE DATE OF FIRST PURCHASE; AND DESA INTERNATIONAL’S LIABILITY IS HEREBY LIMITED TO THE PURCHASE PRICE OF THE PRODUCT AND DESA INTERNATIONAL SHALL NOT BE LIABLE FOR ANY OTHER DAMAGES WHATSOEVER INCLUDING INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES.

Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of incidental or consequential damages, so the above limitation on implied warranties, or exclusion or limitation on damages may not apply to you.

This warranty gives you specific legal rights, and you may also have other rights that vary from state to state.

For information about this warranty write:

INTERNATIONAL

2701 Industrial Drive P.O. Box 90004 Bowling Green, KY 42102-9004 www.desatech.com

105073-01 Rev. C 04/00 NOT A UPC

Model · Date Purchased · 105073 01

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the FMI VFP18R

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the FMI VFP18R

Be the first to ask — other owners or our team will answer.

Original document

FMI VFP18R manual PDF

26 pages·674 KB·Indoor Fireplace·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…