This manual contains important warnings and information. READ AND RETAIN FOR REFERENCE

100 PSI (7 bar) Maximum Working Air Pressure
5000 PSI (333 bar) Maximum Working Fluid Pressure
Part # Min. Max.
965478 1.50 4.50
965466 3.00 9.00
965477 1.00 3.00
965479 2.00 6.00
965481 1.50 4.50
MOVING PARTS HAZARD Relieve fluid and air pressure to unit before servicing unit. Do not operate with panels removed. Follow pressure relief procedure on page 11.
Graco Inc. does not manufacture or supply any of the reactive chemical components that are used in this equipment and is not responsible for their effects. Because of the vast number of chemicals that could be used and their varying chemical reactions, the buyer and user of this equipment should determine all factors relating to the fluids used, including any of the potential hazards involved. Particular inquiry and investigation should be made into potential dangers relating to toxic fumes, fires, explosions, reaction times, and exposure of human beings to the individual components or their resultant mixtures. Graco assumes no responsibility for loss, damage, expense or claims for bodily injury or property damage, direct or consequential, arising from the use of such chemical components.
GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440-1441 Copyright 1998 Graco Inc.
Instructions · Assembly Ratio Ratio



Warning Symbol Caution Symbol WARNING CAUTION
This symbol alerts you to the possibility of serious injury or death if you do not follow the instructions
This symbol alerts you to the possibility of damage to or destruction of equipment if you do not follow the instructions.
BASE: Also called polyol or resin, is one of two reactive chemicals used in a plural component system.
CATALYST: Also called hardener, is the fluid which reacts with the base fluid.
PART: An undefined unit of measurement. When you determine the size of the unit (ounce, pint, gallon), use that measurement consistently in setting up your system.
VRHC: The abbreviation for Variable Ratio Hydra–Cat Pump. This pump automatically proportions and mixes two fluids in a prescribed ratio, which is variable within the ranges listed on the cover.
SPRAY GUN: This term refers to any type of spray gun or dispensing valve used to spray or dispense the fluid being pumped.
Before using this equipment, read the fluid manufacturer’s warnings and determine all facts relating to the fluids used, including any of the potential hazards relating to toxic fumes, fires, explosions, reaction times, and exposure of human beings to the individual components of their resultant mixtures.
MOVING PARTS HAZARD Moving parts, such as the air motor piston and the secondary pump lever and connecting rod area, can
pinch or amputate fingers.
684025 3

4 684025

Spray from the spray gun, hose leaks or ruptured components can inject fluid into your body and cause extremely serious injury, including the need for amputation. Splashing fluid in the eyes or on the skin can also cause serious injury.
684025 5

The following chart gives specifications for the Hydra-Cat H.P. pumps, using No. 10 weight oil. The volumetric ratio is expressed as the proportion of the volume of fluid of the primary pump compared to the volume of fluid of the secondary pump.
For example, Model 965477 has a minimum volumetric ratio of 1:1. At this setting the primary and secondary pumps combined will deliver an output of 3.0 gpm. The maximum volumetric ratio for Model 965477 is 3:1 and the combined output at that setting is 2.0 gpm.
The Typical Installation shown is only a guide to setting up the complete Hydra-Cat H.P. system. For assistance in designing a system to suit your particular needs, contact your nearest Graco representative.
Connect electronically conductive fluid hoses to the pump outlet fittings. Tighten all of the fittings.

Sit the proportioner on a flat floor surface.
Connect the grounded fluid hoses to the pump inlet fittings (P, R). If the unit will be pressure fed from separate supply units, install a fluid pressure gauge at each inlet.
6 684025


A Bleeder Type Main Air Valve B Air Regulator C Pressure Relief
Valve D Mix Manifold E Air Supply Line F Air Line Filter G Air Shutoff Valve H Air Line Lubricator J Base Supply Pump K Catalyst Supply Pressure Pot L Solvent Supply Pump M Mix Manifold Flush
Inlet N Static Mixer P Primary Pump Inlet R Secondary Pump
Inlet S Ratio Adjustment Screw T Spray Gun U Ratio Indicator Plate V Ratio Indicator Pin
Fig. 2 Typical Installation
Refer to Fig. 2.
Connect an electrically conductive air supply hose to the 3/4” npt(f) port of the air manifold (B). Open the bleed-type master air valve (A) and, using the pressure gauge, set the air regulator (B) to the desired pressure. See the Typical Installation and the Parts Drawing.
In the air line, install an air filter (F) to remove harmful dirt and moisture from the compressed air supply. Install an air line lubricator (H) downstream from the air filter, the air regulator (B) and the bleed-type master air valve (A). A lubricator will provide automatic lubrication to the air motor.
All components have rated working pressures of 5000 psi (345 bar) or greater. For more information about the pressure relief valve, see instruction manual 308547.

A bleed-type master air valve (A) is required in your system to relieve the air trapped between the valve and the pump after the pump is shut off. Trapped air can cause the pump to cycle unexpectedly, resulting in possible serious injury, including amputation.
684025 7

Static electricity is created by the high velocity flow of fluid through the pump and hose. If your system is not properly grounded, sparking may occur and the system may become hazardous.
To reduce the risk of static sparking which can result in a fire or explosion and cause serious injury, follow these recommendations for providing electrical continuity throughout your system.
Also, read the WARNING section, FIRE AND EXPLOSION HAZARD on page 4.
Electrical Grounding · 8 684025

Understanding the terms used with the Hydra–Cat (H.P.) System, how it functions, and how to find and set the correct ratios for your application is the key to easier, more versatile operation of your proportional system.
The primary pump (A) is directly under the air motor (H); it usually pumps the base fluid. The secondary pump (B) is on the opposite end of the lever arm (E); it usually pumps the catalyst. The ratio of the secondary pump(s) can be changed by adjusting the ratio adjustment screw (C). See Fig. 4.
Be sure to read and understand the following information before operating the equipment.
There are three main steps when applying the use of ratios: (1) determine the ratio that is required, (2) calculate the ratio setting, and (3) set the ratio on the Hydra-Cat H.P. system.
Ratio refers to the simultaneous output of a certain volume of fluid by the primary and secondary pumps.
Key A Primary Pump B Secondary Pump C Ratio Adjustment Screw
D Wet Cups E Fulcrum and Arm F Primary Pump Output G Secondary Pump Output
H Air Motor I Air Input J Bleed Type Master Air Valve

684025 9

Set the ratio based on your situation. If :
6 parts mixture / 3 parts to reduce 2 parts reducer
5 parts base + 2 parts reducer 7 parts combined base/reducer to 1 part catalyst
changes in the ratio. To prevent evaporation, store the base in a closed container.
The ratio of the pump is 7:1.
and many cause seals to dry out. To prolong the seal life, be sure your pump seals are compatible with the base’s reducer. Contact your Graco representative for the correct seals to use.
Moving the fulcrum point away from the primary pump reduces the secondary stroke length, reducing its fluid output. Moving the fulcrum point closer to the primary pump increases the secondary stroke length, increasing its fluid output.
When adding the reducer to the base before proportioning with the VRHC system, determine the ratio of the base/reducer mixture to the catalyst in order to set the proper ratio.
Fig. 5 shows the relationship between the primary pump and the secondary pump.
Example: The instructions on the can say “Mix 5 parts base to 1 part catalyst. Then reduce 3 parts of this mixture to 1 part reducer.”
See Fig. 2. Use a wrench to rotate the ratio adjustment screw (S). Rotating the screw clockwise will increase the ratio. Rotating the screw counterclockwise will decrease the ratio. The indicator pin (V) will move along the ratio indicator scale (U) as the ratio adjustment screw is rotated. When the pin is above the desired ratio, remove the wrench and perform a ratio test as described on page 12.
5 parts base + 1 parts catalyst 6 parts mixture

10 684025

WARNING System Flushing
The pumps were tested with lightweight oil at the factory. Before operating the pump, thoroughly flush the Hydra-Cat H.P. to prevent contamination of your fluids.
The system pressure must be manually
relieved to prevent the system from starting or spraying accidentally. Fluid under high pressure can be injected through the skin and cause serious injury. To reduce the risk of an injury from injection. To reduce the risk of parts, follow the Pressure Relief Procedure whenever you:
Flush the mixer, hose and gun often enough to prevent fluid from reacting or curing in them. Contact your fluid manufacturer for the effective pot life of the fluid you are using.
Start the Pump 1. Close the bleed-type master air valve, and turn the air regulator knob all the way out (counterclockwise). 2. Turn on the main air supply. 3. With the mixer manifold handle in the open position, trigger the gun, slowly open the bleed-type master air valve, and turn the air regulator knob clockwise until the pump starts. 4. Allow the pump to cycle slowly until all the air is pushed out of the lines. Release the trigger. The pump will stall against the pressure. 5. The manifold handle controls fluid flow. With the lever of the manifold in the open (down) position, base and catalyst are supplied to the gun. To stop the flow, move the handle to the closed (up) position.
Standard Operating Flushing Use the solvent valves to flush contaminants and mixed fluids from the mixer manifold, hose and spray gun. Follow the procedure provided with the mix manifold assembly.
684025 11

operating fluid pressure of the pump. Most mixer manifolds provide a means for checking mix ratio that includes needle valves for adjusting the fluid pressure during the test. The following procedure is an example of how to properly check the mix ratio.
your normal operating pressure, follow the flushing procedure on page 11, then take a sample again. If your sample ratio is incorrect, there is a problem with the sampling valves, ratio setting, or pump operation. Check the ratio setting or service the sampling valves or pump.
Bearings
Wet Cups
Many of the bearing surfaces on the proportioner are permanently lubricated or are self lubricating. There are four main bearings (21) on the lever arm that must be lubricated on a regular interval. The lubrication interval is every six months in single shift operation. To lubricate the bearings, follow the pressure relief procedure on page 11.
Each of the fluid cylinders has a wet cup (18) at the top that must be kept lubricated. See figure 6. The wet cups should be inspected and filled on a weekly basis, or more frequently if found to be dry. To inspect the wet cups, follow the pressure relief procedure on page 11.
To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 11.
To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 11.
With the bleeder type main air valve (1) turned off, remove the thumb screws (14) and the two guards (15) from the sides of the proportioner. The wet cups (18) should be filled to 1/3 full with Graco Throat Seal Liquid (TSL) or compatible solvent.
With the bleeder type main air valve turned off, remove the twenty hex bolts (16) with a 13mm wrench or socket and then remove the four sheet metal covers (17) from the front and back of the proportioner.
The left rear cover may contain a sensor attached to a cable. Do not remove the sensor, but carefully set the cover to the side without straining or damaging the sensor or cable. The four main bearings (21) are now exposed. Use the adapter (205532) provided to grease all four bearings. One or two squirts (2-3 cc) will be sufficient.
The packing nuts (19) are torqued at the factory and are ready for operation. If one becomes loose and there is leaking from the throat packings, relieve the pressure, then torque the nut to 136–149 N.m (100–110 ft-lb) using the supplied wrench (20). Do this whenever necessary. Do not over tighten the packing nut.
12 684025

If your air supply Is very dry, install an air line lubricator between the air regulator and the pump air motor for automatic lubrication. Refer to the air motor manual for details.
Make sure to use an Industrial Grade 1, Heavy Duty, Extreme Pressure, Lithium Soap Grease, Graco Part Number 110293 or equivalent.
Replace the covers (17) and the bolts (16) after greasing, and before starting the machine. The covers (17) are safety guards and must be in place when the proportioner is in operation.

KEY 1 BLEEDER TYPE MAIN AIR VALVE 13 ROD ADAPTER 2 AIR MOTOR 14 THUMB SCREWS 3 PRIMARY CYLINDER 15 GUARDS 4 SECONDARY CYLINDER 16 HEX BOLTS 5 FRAME 17 COVERS 6 AIR MOTOR TIE RODS 18 WET CUPS 7 FLUID CYLINDER TIE RODS 19 PACKING NUTS 8 TIE ROD NUTS 20 PACKING NUT WRENCH 9 CONNECTING ROD NUT, AIR MOTOR 21 MAIN BEARINGS 10 CONNECTING ROD NUT, PRIMARY 22 SNAP RING 11 CONNECTING ROD NUT, SECONDARY 23 FLUID OUTLET, PRIMARY 12 COUPLING COLLARS 24 FLUID OUTLET, SECONDARY
684025 13

Because the pumps are mechanically linked, the action of one pump can affect the readings of the second pump. Therefore, the key to successful troubleshooting is to be sure to isolate the problem.
For example, if the secondary pump pressure, as read on the gauge, is low and sluggish during the pump changeover. The most likely problem is a binding primary pump. To isolate the problem:
Reinstall the guards (15) on both sides of the proportioner. Turn the main air valve (1) back on and carefully increase the air pressure.
A. Open and close the sampling valves and check for pump stalling on both the up and down strokes.
B. Check for rapid gauge response during the pump changeover
To reduce the risk of a serious injury, always follow the Pressure Relief Procedure on page 11 whenever you are instructed to relieve the pressure.
Use very low air pressure to the air motor when troubleshooting the system. This system can produce very high fluid pressure, which can cause serious injury,
including injection, splashing in the eyes or on the skin, and injury from moving parts.
To reduce the risk of a serious injury, always follow the Pressure Relief Procedure on page 11 if the problem you are checking does not require air.
Reinstall the guards (15) on both sides of the proportioner. Turn the main air valve (1) back on and carefully increase the air pressure.
A. Open and close the sampling valves and check for pump stalling on both the up and down strokes.
To reduce the risk of injuring or amputating your hands, fingers, or other body parts, never place your hands, body or tools inside the safety panels for any reason while the unit is operating.
B. Check for rapid gauge response during the pump changeover
14 684025

System will not run or stops while running.
Air pressure or air volume is too low.
Increase air pressure. Check air compressor and air supply filters regulator, lubricator valves and other components for blockages and restrictions. If this is a new system, be sure that air supply components have been sized properly.
The fluid valves or hoses are closed or restricted.
Check the gun, fluid hoses, mix manifold, static mixer, fluid filters, regulators, valves and other fluid line components for blockages and restrictions. If this is a new system, be sure that the fluid components have been sized properly.
The air motor is worn or damaged.
Service the air motor. See “servicing the Air Motor” on page 17.
The displacement cylinder(s) is damaged or has seized
See troubleshooting techniques below to isolate the problem cylinder. See “Service the cylinders” on page 16.
The fluid pressure bounces significantly (>500 psi) while pump is running
Air volume is too low.
Verify that air pressure at the air motor inlet is not dropping during pump changeover. Check air compressor and air supply filters regulator, lubricator valves and other components for blockages and restrictions. If this is a new system, be sure that air supply components have been sized properly. 1” NPT hoses, fittings and accessories are required to provide the necessary air volume.
Feed pump pressure is too high.
Reduce feed pump pressure. Feed pump pressures must be less than 25% of proportioner output pressure.
The displacement cylinder(s) check valves are not seating.
See troubleshooting techniques below to isolate the problem cylinder. See “Service the cylinders” on page 16.
Mix ratio test is significantly different from the mix ratio setting.
Mix ratio test was not performed at the normal operating pressure of the pump
Perform ratio test again following ratio test procedure on page 12.
Running out of one material.
Check and refill material reservoirs. Repeat the test after the air has been removed from the system.
The displacement cylinder(s) are worn or the check valves are not seating.
See troubleshooting techniques below to isolate the problem cylinder(s). See “Service the cylinders” on page 16.
Spray output is spitting Running out of one material.
Check and refill material reservoirs. Remember that once air is in the fluid system it may take a while for all of it to escape..
Siphon hoses are leaking in air.
Tighten and seal all siphon fittings on proportioning pump and feed pumps.
A squeaking or knocking noise is heard.
The bearings are dry or worn.
Lubricate the bearings or replace them if required. See “service the bearings” on page 18.
The proportioner speeds up or runs erratically
Running out of one material.
Check and refill material reservoirs.
The cylinders are worn or damaged.
See troubleshooting techniques below to isolate the problem cylinder(s). See “Service the cylinders” on page 16.
684025 15

To reduce the risk of serious injury or amputation, carefully follow all instructions listed below. In addition, be sure that the pressure relief procedure has been completed and that the main bleeder-type air valve has been turned off and locked out before removing ANY guards or covers from the proportioner.
Be sure to use two people when lifting, moving, or disconnecting the pump. This pump is too heavy for one person. Be sure to support the displacement pump while it is being disconnected, to prevent it from falling and causing injury or property damage. Do this by securely bracing the pump, or by having at least two people hold it while another disconnects it.
from turning. Unscrew the nuts (8) from the tie rods (7). Carefully remove the displacement pump (3)
from the frame.
To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 11.
16 684025

Be sure to use an overhead hoist when lifting, moving or disconnecting the air motor. This air motor weighs 145 lbs. and is too heavy for one person to handle. A lift ring is provided on the motor for this purpose.
Reconnecting the Air Motor
To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 11.
To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 11.
684025 17

To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 11.
2. With the bleeder type main air valve (1) turned off, remove the twenty hex bolts (16) with a 13mm wrench or socket and then remove the four sheet metal covers (17) from the front and back of the proportioner. The left rear cover may contain a sensor attached to a cable. Do not remove the sensor, but carefully set the cover to the side without straining or damaging the sensor or cable. The (4) four main bearings (21) are now exposed.
Bearing Inset · 18 684025


(A) Height 66.0 inch 1676 mm)
(B) Length 31.5 inch (800 mm)
(C) Width 33.0 inch (838 mm)
(D) Air Inlet 3/4 npt(f)
(E) Fluid Inlets Two, 2” npt(f)
(G) Fluid Outlet Two 1/2” npt(f)
(H) Relief Valve Outlets Two, 1/4 npt(m)
Net Weight 700 pounds (320 kg)

Premier Air Consumption At 40 PSI (2.8 bar) CFM M3/min
At 70 PSI (4.9 bar) CFM M3/min
At 100 PSI (7.0 bar) CFM M3/min
per min 13 0.36 20 0.56 26 0.74 5 25 0.71 40 1.13 52 1.48 10 38 1.07 60 1.69 78 2.22 15 50 1.42 80 2.26 104 2.95 20 63 1.78 100 2.82 130 3.69 25 75 2.13 120 3.39 156 4.43 30 88 2.49 140 3.95 183 5.17 35 100 2.84 160 4.52 209 5.91 40

King Air Consumption At 40 PSI (2.8 bar) CFM M3/min
At 70 PSI (4.9 bar) CFM M3/min
At 100 PSI (7.0 bar) CFM M3/min
per min 8 0.23 13 0.36 15 0.43 5 16 0.45 25 0.72 31 0.87 10 24 0.68 38 1.07 46 1.30 15 32 0.90 51 1.43 61 1.74 20 40 1.13 63 1.79 77 2.17 25 48 1.35 76 2.15 92 2.61 30 56 1.58 88 2.51 107 3.04 35 64 1.80 101 2.86 123 3.48 40
684025 19

20 684025

Air motor effective diameter Premier 12.64” (321 mm)
King 10.00” (254 mm) Air motor stroke 4.75” (120 mm) Operating air pressure range 20 to 100 psi (1.4 to 7 bar) Recommended pump speed 40 cycles per minute maximum Maximum fluid inlet pressure 25% of Output or 1000 psi max. Maximum pump operating temperature 180°F (82°C) Wetted parts:
Primary and secondary displacement pumps Carbon Steel; Chrome Steel; Alloy Steel;
Chrome, Zinc, and Nickel Plating; 550 and 17-4 PH Grades of Stainless Steel;
Ductile Iron; Tungsten Carbide; PTFEGlass-Filled PTFE;Leather
Primary and secondary displacement pumps 316, 440 and 17-4 PH Grades of Stainless Steel;
Tungsten Carbide; PTFE; Glass-Filled PTFE; Leather
Fluid hoses Nylon, Zinc-plated steel couplings Pressure relief valves 304 Stainless Steel, Graphite-filled PTFE
Tungsten carbide (Nickel binder)
Premier Noise level at 90 psi (6.3 bar) inlet air and at 40 cpm maximum load 86 dB(A)
King Noise level at 90 psi (6.3 bar) inlet air and 15 cpm maximum load 90.5 dB(A) Pressure
97.7 dB(A) Power

WARRANTY Graco warrants all equipment manufactured by it and bearing its name to be free from defects in material and workmanship on the date of sale by an authorized Graco distributor to the original purchaser for use. As purchaser’s sole remedy for breach of this warranty, Graco will, for a period of twelve months or two thousand hours of operation from time of sale, repair or replace any part of the equipment proven defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written recommendations.
This warranty does not cover, and Graco shall not be liable for, any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility with Graco equipment of structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco.
This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of the claim. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will be made at a reasonable charge, which charges may includes the costs of parts, labor and transportation.
DISCLAIMERS AND LIMITATIONS The terms of this warranty constitute purchaser’s sole and exclusive remedy and are in lieu of any other warranties (express or implied), including warranty of merchantability or warranty of fitness for a particular purpose, and of any non-contractual liabilities, including production liabilities, based on negligence or strict liability. Every form of liability for direct, special or consequential damages or loss is expressly excluded and denied. In no case shall Graco’s liability exceed the amount of the purchase price. Any action for breach of warranty must be brought within two (2) years of the date of sale.
EQUIPMENT NOT COVERED BY GRACO WARRANTY Graco makes no warranty, and disclaims all implied warranties of merchantability and fitness for a particular purpose, with respect to accessories, equipment, materials, or components sold but not manufactured by Graco. These items sold, but not manufactured by Graco (such as electric motor, switches, hose, etc.) are subject to the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these warranties.
FOR TECHNICAL ASSISTANCE, contact your Graco distributor or call one of the following numbers:
1-800-367-4023 612-623-6921 612-378-3505 Fax
Sales Offices: Minneapolis, Detroit International Offices: Belgium, Korea, Hong Kong, Japan GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440-1441 PRINTED IN U.S.A. 684025 Revised 06/2003
22 684025
Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| System will not run or stops while running. | Air pressure or air volume is too low. | Increase air pressure. Check air compressor and air supply filters regulator, lubricator valves and other components for blockages and restrictions. If this is a new system, be sure that air supply components have been sized properly. | p.15 |
| System will not run or stops while running. | The fluid valves or hoses are closed or restricted. | Check the gun, fluid hoses, mix manifold, static mixer, fluid filters, regulators, valves and other fluid line components for blockages and restrictions. If this is a new system, be sure that the fluid components have been sized properly. | p.15 |
| System will not run or stops while running. | The air motor is worn or damaged. | Service the air motor. See “servicing the Air Motor” on page 17. | p.15 |
| System will not run or stops while running. | The displacement cylinder(s) is damaged or has seized | See troubleshooting techniques below to isolate the problem cylinder. See “Service the cylinders” on page 16. | p.15 |
| The fluid pressure bounces significantly (>500 psi) while pump is running | Air volume is too low. | Verify that air pressure at the air motor inlet is not dropping during pump changeover. Check air compressor and air supply filters regulator, lubricator valves and other components for blockages and restrictions. If this is a new system, be sure that air supply components have been sized properly. 1” NPT hoses, fittings and accessories are required to provide the necessary air volume. | p.15 |
| The fluid pressure bounces significantly (>500 psi) while pump is running | Feed pump pressure is too high. | Reduce feed pump pressure. Feed pump pressures must be less than 25% of proportioner output pressure. | p.15 |
| The fluid pressure bounces significantly (>500 psi) while pump is running | The displacement cylinder(s) check valves are not seating. | See troubleshooting techniques below to isolate the problem cylinder. See “Service the cylinders” on page 16. | p.15 |
| Mix ratio test is significantly different from the mix ratio setting. | Mix ratio test was not performed at the normal operating pressure of the pump | Perform ratio test again following ratio test procedure on page 12. | p.15 |
| Mix ratio test is significantly different from the mix ratio setting. | Running out of one material. | Check and refill material reservoirs. Repeat the test after the air has been removed from the system. | p.15 |
| Mix ratio test is significantly different from the mix ratio setting. | The displacement cylinder(s) are worn or the check valves are not seating. | See troubleshooting techniques below to isolate the problem cylinder(s). See “Service the cylinders” on page 16. | p.15 |
| Spray output is spitting | Running out of one material. | Check and refill material reservoirs. Remember that once air is in the fluid system it may take a while for all of it to escape.. | p.15 |
| Spray output is spitting | Siphon hoses are leaking in air. | Tighten and seal all siphon fittings on proportioning pump and feed pumps. | p.15 |
| A squeaking or knocking noise is heard. | The bearings are dry or worn. | Lubricate the bearings or replace them if required. See “service the bearings” on page 18. | p.15 |
| The proportioner speeds up or runs erratically | Running out of one material. | Check and refill material reservoirs. | p.15 |
| The proportioner speeds up or runs erratically | The cylinders are worn or damaged. | See troubleshooting techniques below to isolate the problem cylinder(s). See “Service the cylinders” on page 16. | p.15 |