FMI WCM-42G

40 pages·3.4 MB·Indoor Fireplace·PDF·ENFRITNLJA
FMI WCM-42G
Table of Contents 80 sections Wood Burning Fireplace OWNER’S OPERATION AND INSTALLATION MANUAL · PFS ® · US C · ICC-ES #ESR-2542 · … ShowHide
Wood Burning Fireplace OWNER’S OPERATION AND INSTALLATION MANUALp.1PFS ®p.1US Cp.1ICC-ES #ESR-2542p.1Specificationsp.336" mODELSp.3Figure 1 - 36" Models (V)GM36 Series and WCM-36Gp.3Specifications Continuedp.442" Modelsp.4Figure 2 - 42" Models (V)GM42 Series and WCM-42Gp.450" Modelsp.5Figure 3 - 50" Models (V)GM50 Series and WCM-50Gp.5Fireplace Installationp.6Figure 4 - Framing Dimensionsp.6Figure 5 - Corner Installationp.6Figure 7 - Mantel Clearances top.7Combustible Materialp.7Venting Installationp.8Figure 9 - Lineal Gainp.8Figure 8 - Outside Air Kitp.8OFFSET CHART (22-50 FT. SYSTEM HEIGHT)p.9Figure 11 - Ceiling Support Pipep.912S-12DMp.9Figure 10 - Elbow Offsetp.9Figure 12 - Typical Offset Terminationsp.10Figure 14 - Firestop Spacer with Atticp.10Space Above Ceilingp.10Figure 13 - Firestop Spacer with Livingp.10Roof Opening 36" Modelsp.11Figure 16 - Flashing Installationp.11Roof Opening 42" and 50" Modelsp.11Figure 15 - Roof Opening Measurementsp.11Figure 17 - Storm Collarp.11RTL-10Dp.12Figure 19 - Multiple Chase Installationp.12Figure 18 - Terminationp.12Figure 20 - 10 Foot Rulep.12Optional Gas Line Installationp.13Figure 21 - Gas Line Accessp.13Figure 22 - Gas Line Installationp.13Brick Installation Brick Panel Installationp.14Figure 23 - Hole in Side Panel to Attachp.14to Firebox Wrapperp.14Figure 24 - Installing Brickp.14Brick Installationp.15HEARTH BRICK MATRIXp.15RED IVORY QTY FULL (112140-01)p.15FULL (112140-05)p.15ASH BRICK (120848-01)p.15ASH BRICK (120848-03)p.15F025p.15Continued 36" FULL STACKED BRICK MATRIXp.16F147p.16F148 F148p.16LEFT REFRACTORY RED IVORY QTY FULL (112140-01)p.16F036 F158p.16FULLp.16F143 F143 F144p.16FULL FULLp.16F036p.16F158p.16FULL F036p.16F191 F192p.16F148 F150 F150p.16F159 F159 F159p.16REAR REFRACTORY RED IVORY QTY FULL (112140-01)p.16F160p.16F153p.16F153 F152p.16RIGHT REFRACTORY RED IVORY QTY FULL (112140-01)p.16F192p.16F191p.16Continued 42" FULL STACKED BRICK MATRIXp.1750" FULL STACKED BRICK MATRIXp.1836" FULL HERRINGBONE BRICK MATRIXp.19F074 F074p.19S011p.19F074p.19F187p.19F122p.19
Page 1 of the FMI WCM-42G user manual — Wood Burning Fireplace OWNER’S OPERATION AND INSTALLATION MANUAL
Page 1 · click to enlarge
Page 1

Wood Burning Fireplace OWNER’S OPERATION AND INSTALLATION MANUAL

PFS ®

US C

ICC-ES #ESR-2542

(V)GM36, (V)GM42 AND (V)GM50 Series and WCM-36G,

WCM-42G and WCM-50G Wood Burning Masonry Fireplaces with Insulation

SAVE THIS BOOK This book is valuable. In addition to instructing you on how to install and maintain your appliance, it also contains information that will enable you to obtain re- placement parts or accessory items when needed. Keep it with your other important papers.

This fireplace is approved for use as a wood burning fire- place or for use with a vented gas log approved to ANS Z21.60 or Z21.84 standards or for use with a vent-free gas log heater approved to ANS Z21.11.2 standard.

This wood burning fireplace complies with UL127-CN/ ULC-S610-N87 standard as a FACTORY BUILT APPLI- ANCE.

FOR CANADA: The authority having jurisdiction (such as the municipal building department, fire department, etc.) should be contacted before installation to deter- mine the need to obtain a permit.

INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.

For more information, visit www.fmiproducts.com

Page 2 of the FMI WCM-42G user manual — Wood Burning Fireplace OWNER’S OPERATION AND INSTALLATION MANUAL
Page 2 · click to enlarge
Page 2

Table of Contents Safety 2 Specifications 3 Fireplace Installation 6 Venting Installation 8 Optional Gas Line Installation 13 Brick Installation 14

Glass Door Installation 29 Operation and Maintenance Guidelines 31 Technical Service 33 Replacement Parts 33 Parts 34 Accessories 37 Safety

  • FOR YOUR SAFETY
  • Do not store or use gasoline or any other flammable vapors or liquids in the vicinity of this or any other appliance.
  • Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies.
  • Do not place clothing or other flammable materials on or near the appliance.
  • Never leave children unattended when a fire is burning in the fireplace.
  • Before beginning the installation of the fireplace, read these instructions through completely.
  • This FMI PRODUCTS, LLC fireplace and its components are safe when installed according to this installation manual. Unless you use FMI PRODUCTS, LLC components, which have been designed and tested for the fireplace system, you may cause a fire hazard.
  • The FMI PRODUCTS, LLC warranty will be voided by and FMI PRODUCTS, LLC disclaims any responsibility for the following actions. a. Modification of the fireplace, com-

ponents, doors, air inlet system and damper control. b. Use of any component part not manu-

factured or approved by FMI PROD- UCTS, LLC in combination with a FMI PRODUCTS, LLC fireplace system. Proper installation is the most important step in ensuring safe and continuous operation of the fireplace. Consult the local building codes as to the particular requirements concerned with the installation of all factory built fireplaces.

This fireplace is not intended to be used as a substitute for a furnace to heat an entire home. Use for supplemental heat only.

Page 3 of the FMI WCM-42G user manual — Figure 1 - 36" Models (V)GM36 Series and WCM-36G
Page 3 · click to enlarge
Page 3

Specifications

36" mODELS

FMI WCM-42G — 36" mODELS diagram (page 3)
Fig. 1 · 36" mODELS

14 1/2" 22 1/2"

19 13/16" (Ref.)

3 1/2" 9 1/2" 10 1/2"

7 1/4" 11" 15 1/4"

Figure 1 - 36" Models (V)GM36 Series and WCM-36G

Page 4 of the FMI WCM-42G user manual — Figure 2 - 42" Models (V)GM42 Series and WCM-42G
Page 4 · click to enlarge
Page 4

Specifications Continued

42" Models

FMI WCM-42G — 42" Models diagram (page 4)
Fig. 2 · 42" Models

22 3/4" 30 1/2"

23 13/16" (Ref.)

1 5/16" 41 3/8"

3 1/2" 9 1/2" 10 1/2"

42" 51 1/8" 4 1/2"

Figure 2 - 42" Models (V)GM42 Series and WCM-42G

Page 5 of the FMI WCM-42G user manual — Figure 3 - 50" Models (V)GM50 Series and WCM-50G
Page 5 · click to enlarge
Page 5

Specifications Continued

50" Models

FMI WCM-42G — 50" Models diagram (page 5)
Fig. 3 · 50" Models
FMI WCM-42G — 50" Models diagram (page 5)
Fig. 4 · 50" Models

23 13/16" (Ref.)

3 1/2" 9 1/2" 10 1/2"

Figure 3 - 50" Models (V)GM50 Series and WCM-50G

Page 6 of the FMI WCM-42G user manual — Figure 5 - Corner Installation
Page 6 · click to enlarge
Page 6

Fireplace Installation

selecting location To determine the safest and most efficient location for the fireplace, you must take into consideration the following guidelines: 1. The location must allow for proper clear- ances (see Figures 4 and 5). 2. Consider a location where fireplace will not be affected by drafts, air conditioning ducts, windows or doors. 3. A location that avoids cutting of joists or roof rafters will make installation easier. 4. An outside air kit is available with this fireplace (see Optional Outside Air Kit on page 8).

Framing 1. Frame opening for fireplace using dimen- sions shown in Figures 4 and 5. 2. If fireplace is to be installed directly on carpeting, tile (other than ceramic) or any combustible material other than wood flooring, fireplace must be installed upon a metal or wood panel extending full width and depth of fireplace. 3. Set fireplace directly in front of this open- ing and slide unit back until nailing flanges touch side framing. 4. Check level of the fireplace and shim with sheet metal if necessary. 5. Before securing fireplace to prepared framing, ember protector (provided) must be placed between hearth extension (not supplied) and under bottom front edge of fireplace to protect against glowing embers falling through. If fireplace is to be installed on a raised platform, a Z-type ember pro- tector (not supplied) must be fabricated to fit your required platform height. Ember protector should extend under fireplace a minimum of 1 1/2". Ember protector should be made of galvanized sheet metal (28 gauge minimum to prevent corrosion. 6. Using screws or nails, secure fireplace to framing through flanges located on sides of fireplace.

Minimum clearance to combustibles Back and sides of fireplace 1 1/2" min.* Front of fireplace 48" min. Floor** 0" min. Perpendicular wall to opening 18" min. 36" Models 12" min. Top spacers 0" min. Mantel clearances see Mantels, page 7 Chimney outer pipe surface 2" min. 36" Model 1" min. * Not required at nailing flanges ** See step 2 of Framing

Minimum/Maximum Chimney Height for Residential Installation Minimum height of chimney, measured from base of fireplace to flue gas outlet of termina- tion, is 16 feet for straight flue or a flue with one elbow set. Maximum distance between elbows is 6 feet. For systems with two elbow sets, minimum height is 22 feet. Maximum height of any system is 50 feet. This measure- ment includes fireplace, chimney sections and height of termination assembly at level of the flue gas outlet (see Figure 15, page 11).

67.125"

58.125"

51.25" (42" Models) 45.25" (36" Models)

30.125"

28.250" (36" Models)

Figure 4 - Framing Dimensions

61" (36" Models) Maintain 1 1/2" Clearance at Sides and Back of Fireplace

1 1/2" Clearance Not Required at Nailing Flanges

92" (42" Models) 86.5" (36" Models)

Figure 5 - Corner Installation

Show 4 more labels / short text on this page
59" (50" Models) · 65" (42" Models) · 71" (50" Models) · 100" (50" Models)
Page 7 of the FMI WCM-42G user manual — Figure 7 - Mantel Clearances to
Page 7 · click to enlarge
Page 7

Fireplace Installation

Hearth Extension A hearth extension projecting a minimum of 20" in front of and a minimum of 12" beyond each side of fireplace opening is required to protect combustible floor construction in front of fireplace. Fabricate a hearth extension using a material which meets the following specifications: a layer of noncombustible, inorganic material having a thermal conduc- tivity of K=0.84 BTU IN/FT, HR. F (or less) at 1" thick. For example, if the material selected has a K factor of 0.25, such as glass fiber, the following formula would apply: 0.25 x 1.0" = 0.30" thickness required 0.84 Thermal conductivity "K" of materials can be obtained from manufacturer or supplier of noncombustible material. If hearth extension is to be covered, use noncombustible mate- rial such as tile, slate, brick, concrete, metal, glass, marble, stone, etc. Provide a means to prevent hearth extension from shifting and seal gap between fireplace frame and hearth extension with a noncombustible material (see Figure 6).

Mantels A mantel may be installed if desired (see Figure 7). Woodwork such as wood trims, mantels or any other combustible material projecting from front face must not be placed within 12" (36" Models) or 18" (42/50" Models) of fireplace opening. Combustible materials above 12" (36" Models) or 18" (42/50" Models) and projecting more than 1 1/2" from fireplace must not be placed less than 15" (36" Models) or 21" (42/50" Models) from the top opening of the fireplace (NFPA STD 211, Sec. 7-3.3.3). Mantels or any other combustible material also may come up to side edge of black metal face of fireplace as long as projections from front face fall within limit shown in Figure 7.

FMI WCM-42G — Fireplace Installation diagram (page 7)
Fig. 5 · Fireplace Installation

33° Combustible Material Must Not Overlap Front Face 12" - 36" Models 18" - 42/50" Models

Figure 7 - Mantel Clearances to

Combustible Material

Page 8 of the FMI WCM-42G user manual — Figure 9 - Lineal Gain
Page 8 · click to enlarge
Page 8

Venting Installation

Optional Outside air Kit (Model ak4/ak4f) The installation of an outside air kit should be performed during the rough framing of the fireplace due to the nature of it's location. Outside combustion air is accessed through a vented crawl space (AK4F) or through a sidewall (AK4).

LINEAL GAIN PART NO.DESCRIPTIONGAIN GeorgianFireplace66 1/ 2" 12-12DM 12-12HTPipe Section10 5/ 8" 18-12DM 18-12HTPipe Section16 5/ 8" 24-12DM 24-12HTPipe Section23 5/ 8" 36-12DM 36-12HTPipe Section34 5/ 8" 48-12DM 48-12HTPipe Section46 5/ 8" RLT-12D RLT-12HTRound Termination7 3/ 4"* STL-12DSquare Chase-Top with Slip Section7" to 15"*

The maximum height for the air vent can not exceed 3 feet below the flue gas outlet of the termination.

Secure to Collars with Metal Tape, Screws or Straps (Min. of 1/4" x 20" in size)

Air Inlet Location Must Allow For Bushes or Snow

* The lineal gain for the terminations is mea- sured to the flue gas outlet height.

15" Galvanized Outer Pipe

Hemmed End 12 3/8" Stainless Inner Pipe

Vent Hood Required for Wall Installation

Vented Crawl Space (Check Local Codes Before Installing in a Vented Crawl Space)

Figure 9 - Lineal Gain

Figure 8 - Outside Air Kit

Chimney Pipe The FMI PRODUCTS, LLC chimney system consists of 12", 18", 24", 36" and 48" snap- lock, double-wall pipe segments, planned for maximum adaptability to individual site requirements. Actual lengths gained after fitting overlaps must be taken into consider- ation (lineal gain) and are given in the lineal gain chart (see Figure 9). Lineal Gain is the actual measurable length of a part after two or more parts are connected. For Canada, use chimney parts designated "HT".

Assembly and installation of double wall chimney system Each double wall chimney section consists of a galvanized outer pipe, a stainless steel inner flue pipe and a wire spacer. The pipe sections must be assembled independently as the chimney is installed. When connecting chimney directly to the fireplace, the inner flue pipe section must be installed first with the lanced side up. The outer pipe section can then be installed over 5 the flue pipe section with the hemmed end up. Press down on each pipe section until the lances securely engage the hem on the fireplace starter. The wire will assure the proper spacing between the inner and outer pipe sections.

Air Inlet Eyebrow

Page 9 of the FMI WCM-42G user manual — OFFSET CHART (22-50 FT. SYSTEM HEIGHT)
Page 9 · click to enlarge
Page 9

Venting Installation

Continue to assemble chimney sections as outlined above, making sure that both the inner and outer pipe sections are locked to- gether. When installing double wall snap-lock chimney together, it is important to assure the joint between the chimney sections is locked. Check by pulling chimney upward after locking. The chimney will not come apart

if properly locked. It is not necessary to add screws to keep the chimney together (excep- tion, see Figure 10).

Using ELBOW offsets (30E-12DM) 1. To achieve desired offset, you may install combinations of 12", 18", 24", 36" and 48" length of double wall pipe (see offset chart and Figure 10). 2. Chimney weight above offset rests on return elbow. Straps must be securely nailed to rafters or joists (see Figure 11, details A and B). 3. Maximum length of pipe between sup- ports (return elbow or 12S-12DM) is 6' of angle run. Maximum of two 6' angle run sections per chimney system (see Figure 12, page 10). 4. All pipe connections between the offset and return must be secured with two screws on the outer pipe only (see Figure 10). Do not penetrate the inner stainless.

OFFSETRISECHIMNEY LENGTH AB12"18"24"36"48" 4 3/" 816 3/" 8ELBOW SET ONLY 9 3/" 425 1/" 21 12 3/" 430 3/" 41 15"34 3/" 41 18"40"11 21 1/" 446 1/" 41 23 3/" 449 1/" 411 27 3/" 456 3/" 41 30"60 3/" 411 33"66"1 36"71"11 38 1/" 475"2 41 1/" 480 1/" 4111 45"86 3/" 42 46 3/" 489 1/" 2111 51"97"11 53 1/" 4101"2 56 1/" 4106 1/" 42 59 1/" 4111 1/" 2111 61 3/" 4115 1/" 212 64 3/" 4120 3/" 412 68 1/" 4127"21 70"130"112 74 1/" 4 3137 1/" 2 1121 76 /" 4 79 3/" 4141 /" 2 146 3/" 412 41
See Detail A 2" Min. Straps Straps Detail B See Detail B Angle Firestop traps StrapsSeeDetail A
FMI WCM-42G — Venting Installation diagram (page 9)
Fig. 6 · Venting Installation

OFFSET CHART (22-50 FT. SYSTEM HEIGHT)

Figure 11 - Ceiling Support Pipe

12S-12DM

B

A

Figure 10 - Elbow Offset

Screws

Page 10 of the FMI WCM-42G user manual — Figure 13 - Firestop Spacer with Living
Page 10 · click to enlarge
Page 10

Venting Installation

FMI WCM-42G — Venting Installation diagram (page 10)
Fig. 7 · Venting Installation

Figure 12 - Typical Offset Terminations

Firestop Spacers (FS-10, 1100EFS-10DM for 36" Models) Firestop spacers are required at each point where the chimney penetrates a floor space. Their purpose is to establish and maintain the required clearance between the chimney and the combustible materials. When the pipe passes through a framed opening into a living space above, the firestop must be placed onto the ceiling from below as shown in Figure 13. They also provide complete separation from one floor space to another or attic space as required by most codes. When the double wall pipe passes through a framed opening into an attic space, the firestop must be placed into an attic floor as shown in Figure 14.

FMI WCM-42G — Figure 12 - Typical Offset Terminations diagram (page 10)
Fig. 8 · Figure 12 - Typical Offset Terminations

Figure 14 - Firestop Spacer with Attic

Space Above Ceiling

Penetrating roof To maintain a 1" (36" Models) or 2" (42/50" Models) clearance to the pipe on a roof with a pitch, a rectangular opening must be cut. 1. Determine center point through which pipe will penetrate roof. 2. Determine center point of roof. Pitch is distance the roof drops over a given span, usually 12". A 6/12 pitch means that roof drops 6" for each 12" measured horizon- tally down from roof rafters. 3. Use roof opening chart (Figure 15, page 11) to determine correct opening length and flashing required. 4. Remove shingles around opening mea- sured. Cut out this section.

FMI WCM-42G — Figure 14 - Firestop Spacer with Attic diagram (page 10)
Fig. 9 · Figure 14 - Firestop Spacer with Attic

Screws or Staples (Min. of 8)

Figure 13 - Firestop Spacer with Living

Space Above Ceiling

Return Elbow · Existing Ceiling Frame · Firestop Spacer

Page 11 of the FMI WCM-42G user manual — Roof Opening 42" and 50" Models
Page 11 · click to enlarge
Page 11

Venting Installation

5. Add next sections of pipe until end penetrates roof line. Check to see that proper clearances are maintained. Extend chimney by adding sections of double wall pipe until pipe is minimum of 30" above highest point of roof cutout. Termination and chimney must extend a minimum of 36" above highest point where it passes through roof.

Flashing installation (v6f-10dm or v12f-10dm) Determine the flashing to be used with the roof opening chart. Slide flashing over pipe until base is flat against roof. Replace as many shingles as needed to cover exposed area and flashing base. Secure in position by nail- ing through shingles (see Figure 16). DO NOT NAIL THROUGH FLASHING CONE.

17" Min. 30" Mi 1" Min. 1" Min. 1" Min. Opening "A" PitchSlopeOpening "A" Max.Used Flashing Model No. Flat0°17"V6F-10DM 0-6/1226.6°19"V6F-10DM 6/1212/1245.0°24"V12F-10DM

Installing Flashing on a Metal Roof When installing the flashing on a metal roof, it is required that putty tape be used between the flashing and the roof. The flashing must be secured to the roof using #8 x 3/4" screws and then sealed with roof coating to prevent leak- age through the screw holes. A roof coating must also be applied around the perimeter of the flashing to provide a proper seal.

Overlap Shingles Top and Sides Only

Nail Only Outer Perimeter of Flashing

Roof Opening 36" Models

19.5" Min. 30" Min. 2" Min.

Underlap Shingles at Bottom

2" Min.

Figure 16 - Flashing Installation

2" Min.

Storm Collar Installation (SC2-1) Place storm collar over pipe and slide down until it is snug against the open edge of the flashing (see Figure 17). Apply waterproof caulk around the perimeter of the collar to provide a proper seal.

PitchSlopeOpening "A" Max.Used Flashing Model No. Flat0°19.5"V6F-10DM 0-6/1226.6°22'V6F-10DM 6/12-12/1245.0°27"V12F-10DM

Roof Opening 42" and 50" Models

Figure 15 - Roof Opening Measurements

Figure 17 - Storm Collar

Show 6 more labels / short text on this page
Storm Collar · Flashing Cone · Opening "A" · Chimney Pipe · Waterproof Caulk · Storm Collar Flashing
Page 12 of the FMI WCM-42G user manual — Figure 20 - 10 Foot Rule
Page 12 · click to enlarge
Page 12

Venting Installation

Terminations/Spark Arrestor The fireplace system must be terminated with the listed round top or chase terminations. In any case, refer to the installation instructions supplied with the termination.

18" Min. Typ.

24" Min.

24" Min.

RTL-10D

Stainless Inner Flue Pipe

Level of Flue Gas Outlet

Figure 19 - Multiple Chase Installation

10 foot rule All flue gas outlet chimney terminations must extend a minimum of 3 feet in height above the highest point where it passes through the roof and must be at least 2 feet above the high- est point of the roof that is within a horizontal distance of 10 feet (see Figure 20).

Secure Termination to Outer Pipe with 3 Screws

Level of Flue Gas Outlet

2' Min.

3' Min.

Overlap Shingles (Top and Sides of Flashing Base)

2' Min. 3' Min.

Figure 18 - Termination

Chase installations Instructions for chase installations are included with the chase style termination chosen. In a multiple chase installation, be sure to provide adequate distance between terminations to prevent smoke spillage from one termination to another. We suggest that terminations be separated at least 24", center to center and stacked at a vertical height dif- ference of 18" (see Figure 19). Note: If a decorative shroud is to be installed, contact the manufacturer for specifications.

Figure 20 - 10 Foot Rule

finishing fireplace Combustible materials, such as wallboard, gypsum board, sheet rock, drywall, plywood, etc. may make direct contact with sides and top around the fireplace face. It is important that combustible materials do not overlap the face itself. Brick, glass, tile or other noncombustible materials may overlap the front face provided they do not obstruct essential openings like louvered slots or any other opening. When overlapping with a noncombustible facing material, use only noncombustible mortar or adhesive.

Show 6 more labels / short text on this page
Waterproof Caulking · Storm Collar · 10' · Flashing · 10' · Underlap Shingles
Page 13 of the FMI WCM-42G user manual — Figure 22 - Gas Line Installation
Page 13 · click to enlarge
Page 13

Optional Gas Line Installation

Gas line hook up should be done by your supplier or a qualified service person. Note: Before you proceed, make sure your gas supply is turned off. Use only a 1/2" black iron pipe and appropri- ate fittings. 1. Remove knockout indentation on refrac- tory or firebrick wall located above refrac- tory hearth floor. Knockout indentation must be firmly tapped with any solid object such as a 1/2" dowel until it is released. Remove fragmented portions of refractory (see Figure 21). 2. Remove gas line cover plate located on either side of fireplace and pull out insula- tion from gas line conduit sleeve. Save insulation for reuse. Replace screws. 3. Run a 1/2" black iron gas line into fireplace through the rear at gas line conduit sleeve (if using a raised platform, add height). Provide sufficient gas line into fireplace chamber for fitting connection (see Figure 22). Note: Secure incoming gas line to wood framing to provide rigidity for threaded end. 4. Repack insulation around gas line and into sleeve opening. Seal any gaps between gas line and refractory knockout hole with refractory cement or commercial furnace cement, Install the gas appliance or cap-off gas line if desired.

If you install a decorative gas appliance (vented gas log), the decorative gas appliance must comply with the Standard for Decorative Gas Appliance for Installation in Solid Fuel Burning Fireplaces, ANS Z21.60 or Z21.84 and shall also be installed in accordance with the National Fuel Gas Code, ANSI 7223NFPA 54 latest edition.

Side Firebrick Finished Side

CAUTION: All gas piping and connections must be tested for leaks after the installation is completed. After ensuring that the gas valve is on, apply soap and water solution to all connections and joints. Bubbles forming show a leak. Correct all leaks at once. DO NOT USE AN OPEN FLAME FOR LEAK TESTING AND DO NOT OPER- ATE ANY APPLIANCE IF A LEAK IS DETECTED. LEAK TESTING SHOULD BE DONE BY A QUALI- FIED SERVICE PERSON.

Brick with Access Hole

Figure 21 - Gas Line Access

Side Firebrick Finished Side

Incoming 1/2" Black Iron Pipe

Seal Opening with Refractory Cement

Provide Enough Threaded End for Fitting Connection

Figure 22 - Gas Line Installation

Show 9 more labels / short text on this page
Outside of Fireplace · Gas Line Conduit · Remove Knockout · 1/2" Dowel · Insulation · Gas Conduit Cover · Outside of Fireplace · Gas Line Conduit · Repack Insulation
Page 14 of the FMI WCM-42G user manual — Figure 23 - Hole in Side Panel to Attach
Page 14 · click to enlarge
Page 14

Brick Installation Brick Panel Installation

Brick Installation Each brick housing is stamped with a number (full size bricks are not stamped). These num- bers will help identify the brick when installing. It is important to install these bricks exactly as instructed. Press brick firmly into brick housing until it snaps. Groove line on side of brick will come in contact with flange on the brick hous- ing. This secures brick into housing (see Figure 24). Smaller bricks may require a small portion of furnace cement applied to back of brick to secure it until grouting has been completed. Bricks are packaged in separate boxes. The brick matrixes on pages 15 through 27 show how bricks are packaged and placed for each size fireplace and the number of bricks per box. There are 2 extra full bricks included in Hearth Brick package. Install bricks one section at a time starting with hearth panel followed by the rear panel, left panel and right panel. It is important to install the bricks in sequence. Please note, full size bricks are NOT stamped.

The brick housings are already installed on the panels. When installing brick housing panels into fireplace, wear gloves as edges may be sharp. 1. Beginning with left side panel, place panel, bottom edge first, at an angle into fireplace. Secure to bottom of fireplace with screws provided. 2. Install right side as left side in step 1 using screws provided. 3. Install back panel and secure back to sides and bottom of firebox with screws provided. 4. Using self-tapping screws and a drill, place screws into large holes in back and side panels (see Parts, page 34), through wire mesh and into firebox wrapper to secure.

Brick Stamped Letter Location

Hole in Side Panel

Figure 23 - Hole in Side Panel to Attach

to Firebox Wrapper

Figure 24 - Installing Brick

Flanges · Brick Housing

Page 15 of the FMI WCM-42G user manual — F025
Page 15 · click to enlarge
Page 15

Brick Installation

HEARTH BRICK MATRIX

RED IVORY QTY FULL (112140-01)

FMI WCM-42G — HEARTH BRICK MATRIX diagram (page 15)
Fig. 10

FULL (112140-05)

ASH BRICK (120848-01)

ASH BRICK (120848-03)

F012R F012W 2 F124R F124W 2 F125R F125W 2 F126R F126W 2 F128R F128W 2 * Includes 2 extra bricks.

RED IVORY QTY FULL (112140-01)

FULL (112140-05)

FMI WCM-42G — RED IVORY QTY FULL (112140-01) diagram (page 15)
Fig. 11

ASH BRICK (120848-01)

ASH BRICK (120848-03)

F011R F011W 1 F059R F059W 4 F123R F123W 2 F124R F124W 2 F126R F126W 2 F132R F132W 2 F133R F133W 2 * Includes 2 extra bricks.

RED IVORY QTY FULL (112140-01)

FMI WCM-42G — RED IVORY QTY FULL (112140-01) diagram (page 15)
Fig. 12

FULL (112140-05)

ASH BRICK (120848-01)

ASH BRICK (120848-03)

F011R F011W 3 F012R F012W 2 F021R F021W 2 F024R F024W 2 F025R F025W 2 F059R F059W 2 F126R F126W 2 F134R F134W 2 F135R F135W 2 * Includes 2 extra bricks.

F025

F025

Show 6 more labels / short text on this page
11* · 36" Hearth · 13* · 42" Hearth · 17* · 50" Hearth
Page 16 of the FMI WCM-42G user manual — F158
Page 16 · click to enlarge
Page 16

Brick Installation

Continued 36" FULL STACKED BRICK MATRIX

F147

F148 F148

LEFT REFRACTORY RED IVORY QTY FULL (112140-01)

F036 F158

FULL

FULL (112140-05)

F143 F143 F144

FULL FULL

F036R F036W 3 F143R F143W 2 F144R F144W 1 F147R F147W 1 F148R F148W 2 F158R F158W 3 F185R F185W 1 F191R F191W 1 F192R F192W 1

F036

FULL

F158

FULL FULL

FULL F036

F158

F191 F192

F148 F150 F150

F159 F159 F159

F159 F159 F159

REAR REFRACTORY RED IVORY QTY FULL (112140-01)

FULL FULL

FULL (112140-05)

F160

FULL

F160

F148R F148W 1 F150R F150W 2 F152R F152W 1 F153R F153W 2 F159R F159W 6 F160R F160W 4

FULL FULL

F160

FULL

F160

FULL FULL

F153

F153 F152

F147

F148 F148

RIGHT REFRACTORY RED IVORY QTY FULL (112140-01)

F036 F158

FULL

FULL (112140-05)

F143 F143 F144

FULL FULL

F036R F036W 3 F143R F143W 2 F144R F144W 1 F147R F147W 1 F148R F148W 2 F158R F158W 3 F185R F185W 1 F191R F195W 1 F192R F192W 1

F158

FULL

F036

FULL FULL

F158

FULL F036

F192

F191

F185 or · F185 or

Page 17 of the FMI WCM-42G user manual — RIGHT REFRACTORY RED IVORY QTY FULL (112140-01)
Page 17 · click to enlarge
Page 17

Brick Installation

Continued 42" FULL STACKED BRICK MATRIX

FMI WCM-42G — Continued 42" FULL STACKED BRICK MATRIX diagram (page 17)
Fig. 13 · Continued 42" FULL STACKED BRICK MATRIX

F017R F017W 1 F032R F032W 3 F033R F033W 3 F143R F143W 3 F151R F151W 1 F155R F155W 1 F156R F156W 1 F158R F158W 2 F186R F186W 1 F190R F190W 1

FMI WCM-42G — Continued 42" FULL STACKED BRICK MATRIX diagram (page 17)
Fig. 14 · Continued 42" FULL STACKED BRICK MATRIX

REAR REFRACTORY RED IVORY QTY FULL (112140-01)

FULL (112140-05)

F017R F017W 2 F032R F032W 6 F033R F033W 4 F152R F152W 2 F154R F154W 2 F157R F157W 2

RIGHT REFRACTORY RED IVORY QTY FULL (112140-01)

FULL (112140-05)

F017R F017W 1 F032R F032W 3 F033R F033W 3 F143R F143W 3 F151R F151W 1 F155R F155W 1 F156R F156W 1 F158R F158W 2 F186R F186W 1 F190R F190W 1

Page 18 of the FMI WCM-42G user manual — RIGHT REFRACTORY RED IVORY QTY FULL (112140-01)
Page 18 · click to enlarge
Page 18

Brick Installation

50" FULL STACKED BRICK MATRIX

LEFT REFRACTORY RED IVORY QTY FULL (112140-01)

FMI WCM-42G — 50" FULL STACKED BRICK MATRIX diagram (page 18)
Fig. 15

FULL (112140-05)

F032R F032W 3 F033R F033W 3 F143R F143W 2 F144R F144W 1 F145R F145W 1 F146R F146W 1 F147R F147W 1 F148R F148W 2 F149R F149W 1

F158R F158W 3 F191R F191W 1 F192R F191W 1

FMI WCM-42G — FULL (112140-05) diagram (page 18)
Fig. 16

REAR REFRACTORY RED IVORY QTY FULL (112140-01)

FULL (112140-05)

F148R F148W 2 F150R F150W 2 F152R F152W 2 F153R F153W 2 F159R F159W 6 F160R F160W 4

RIGHT REFRACTORY RED IVORY QTY FULL (112140-01)

FULL (112140-05)

F032R F032W 3 F033R F033W 3 F143R F143W 2 F144R F144W 1 F145R F145W 1 F146R F146W 1 F147R F147W 1 F148R F148W 2 F149R F149W 1 F158R F158W 3 F191R F191W 1 F192R F192W 1

Page 19 of the FMI WCM-42G user manual — F122
Page 19 · click to enlarge
Page 19

Brick Installation

36" FULL HERRINGBONE BRICK MATRIX

F074 F074

LEFT REFRACTORY RED IVORY QTY FULL (112140-01)

FMI WCM-42G — 36" FULL HERRINGBONE BRICK MATRIX diagram (page 19)
Fig. 17

FULL (112140-05)

F068R F068W 1 F071R F071W 1 F072R F072W 5 F074R F074W 2 F113R F113W 3 F115R F115W 1 F165R F165W 1 F181R F181W 1 F189R F189W 1 S011R S011W 1

S011

FMI WCM-42G — S011 diagram (page 19)
Fig. 18

F074 F074

REAR REFRACTORY RED IVORY QTY FULL (112140-01)

F074

FULL (112140-05)

F068R F068W 1 F072R F072W 1 F074R F074W 6 F084R F084W 3 F107R F107W 3 F108R F108W 1 F117R F117W 1 F161R F161W 1 F168R F168W 2 F179R F179W 1 F187R F187W 1

F074

F074

F074

F187

RIGHT REFRACTORY RED IVORY QTY FULL (112140-01)

FULL (112140-05)

F122

F068R F068W 4 F071R F071W 1 F072R F072W 1 F074R F074W 2 F110R F110W 3 F112R F112W 1 F120R F120W 4 F122R F122W 4 F180R F180W 1 F181R F181W 1 F188R F188W 1

F122

F122

F122

F074

F181 or F071 · F181 or F071

Page 20 of the FMI WCM-42G user manual — FULL (112140-05)
Page 20 · click to enlarge
Page 20

Brick Installation

42" FULL HERRINGBONE BRICK MATRIX

F074 F074

LEFT REFRACTORY RED IVORY QTY FULL (112140-01)

FMI WCM-42G — 42" FULL HERRINGBONE BRICK MATRIX diagram (page 20)
Fig. 19

F120

FULL (112140-05)

F120

F064R F064W 4 F068R F068W 4 F072R F072W 2 F074R F074W 2 F120R F120W 4 F163R F163W 1 F169R F169W 1 F175R F175W 1 F176R F176W 1 F177R F177W 1 F182R F182W 1

F120

F120

F176

F177

F074 F074

FMI WCM-42G — F120 diagram (page 20)
Fig. 20

REAR REFRACTORY RED IVORY QTY FULL (112140-01)

FULL (112140-05)

F063R F063W 3 F068R F068W 1 F072R F072W 6 F074R F074W 2 F089R F089W 1 F161R F161W 2

F168R F168W 1

F171R F171W 1

F178R F178W 1

F171

F074

RIGHT REFRACTORY RED IVORY QTY FULL (112140-01)

FMI WCM-42G — F168R F168W 1 diagram (page 20)
Fig. 21

FULL (112140-05)

F068R F068W 1 F071R F071W 4 F072R F072W 2 F074R F074W 1 F100R F100W 3 F101R F101W 1 F162R F162W 1 F164R F164W 1 F165R F165W 1 F174R F174W 1

F175 or F182 · F162 or F184

Page 21 of the FMI WCM-42G user manual — FULL (112140-05)
Page 21 · click to enlarge
Page 21

Brick Installation

50" FULL HERRINGBONE BRICK MATRIX

LEFT REFRACTORY RED IVORY QTY FULL (112140-01)

F074 F074

FMI WCM-42G — 50" FULL HERRINGBONE BRICK MATRIX diagram (page 21)
Fig. 22

F120

FULL (112140-05)

F064R F064W 4 F068R F068W 4 F072R F072W 2

F120

F074R F074W 2 F120R F120W 4 F163R F163W 1 F169R F169W 1 F175R F175W 1 F176R F176W 1

F120

F120

F176

F177R F177W 1 F182R F182W 1

F177

REAR REFRACTORY RED IVORY QTY FULL (112140-01)

F074

F074

FMI WCM-42G — F120 diagram (page 21)
Fig. 23

FULL (112140-05)

F063R F063W 3 F065R F065W 3 F068R F068W 2 F072R F072W 2 F074R F074W 2 F082R F082W 1

F089R F089W 1

F161R F161W 2

F168R F168W 2

F170R F170W 1

F178R F178W 1

F178

RIGHT REFRACTORY RED IVORY QTY FULL (112140-01)

F093 F074 F074

FMI WCM-42G — F089R F089W 1 diagram (page 21)
Fig. 24

FULL (112140-05)

F068R F068W 2 F072R F072W 1 F074R F074W 2 F083R F083W 3 F084R F084W 4 F085R F085W 1 F093R F093W 1 F166R F166W 1 F167R F167W 1 F172R F172W 1 F173R F173W 1 F183R F183W 1

F175 or F182

Page 22 of the FMI WCM-42G user manual — Figure 25 - Grouting Brick
Page 22 · click to enlarge
Page 22

Brick Installation

Grouting instructions Material provided: 1 or 2 - 10 lb. bags of cement (depending on model) 1 or 2 - 10 lb. bags of sand (depending on model) Material required: 1 - Piping bag 1 - Joints striker 1 - Heavy duty mixing bucket 1 - Trowel 1. Moisten brick surface with damp sponge or spray bottle just prior to application. When bricks are wet, any excess grout mixture on bricks will easily wipe off. 2. In a heavy duty mixing bucket, pour 4 ½ cups of water. Add 5 lbs. (half of a bag) of sand and 5 lbs (half of a bag) of cement. Mix together well using a power drill with mixing wand attachment to a yogurt like consistency. Not adding enough water can lead to grout falling out after burning. 3. The overall length of piping bag should be about 16". If the bag is longer than 16", cut it down to size by removing end with larger opening. This will make the bag easier to handle. 4. Put 2 to 3 cups of grout mixture into piping bag making sure the smaller opening is downward and over a moist towel to avoid spilling. Place a wet towel over the bucket making sure it is directly on the surface of grout mixture. This will keep the mixture moist and it will not dry out before use. 5. Begin grouting by first doing a “Filler Pass”. This is done by filling the joint about 3/4 full with grout mixture. It is important to work with only 6 bricks at a time so grout doesn't have time to set up before striking. 6. Complete a “Finishing Pass” around 6 bricks you just put filler pass around. This is done by slowly filling in remainder of the joint with a thick amount of grout mixture.

Mixture should be a little higher than the brick surface. 7. Using a trowel, remove excess grout mix- ture by moving trowel in the direction of the joint. Grout mixture in the joint should now be flush with brick surface. If not enough grout is applied into each space, grout may fall out after burning. 8. Using a joint striker, force grout mixture into joint and sweep back and forth until grout is smooth and round. If grout becomes too shallow, add more grout mixture with piping bag and strike again. 9. Continue procedure around each group of 6 bricks until an entire panel is finished. 10. Using trowel, scrape in direction of joints to remove any grout that may have col- lected around bricks during striking. If desired, take a moist sponge and lightly sweep over bricks to remove any grout that may have gotten on bricks. DO NO PRESS HARD OR RUB IN A CIRCULAR MOTION. This will press the grout into brick and turn brick a different color.

Allow 72 hours before

operating fireplace.

FMI WCM-42G — Allow 72 hours before diagram (page 22)
Fig. 25 · Allow 72 hours before

Figure 25 - Grouting Brick

Page 23 of the FMI WCM-42G user manual — Figure 27 - Assembling Door Frame
Page 23 · click to enlarge
Page 23

Brick Installation

INSTALLING FIREPLACE HOOD AND SCREEN 1. Mount screen rod brackets on left and right side of smoke shelf with #8 x 1/2" screws provided (see Figure 27, page 29). 2. Slide round end of screen rod into rings at top of screen. Attach one push-on nut to end of rod before attaching last ring of screen. 3. Insert round end of rod into rod bracket on left side of fireplace. 4. Mount flat end of screen rod with #10 x 5/8" to center of smoke shelf (see Figure 26). 5. Install other screen rod in same manner.

FMI WCM-42G — Brick Installation diagram (page 23)
Fig. 26 · Brick Installation

Figure 26 - Installing Fireplace Screen

Glass Door Installation

Installation To install glass door frame, construct an opening (see table) on the front face of the fireplace. Insert door frame into face opening and tighten screws (see Figure 28).

FMI WCM-42G — Figure 26 - Installing Fireplace Screen diagram (page 23)
Fig. 27 · Figure 26 - Installing Fireplace Screen

Assembly Insert L-shaped gussets starting at the left top portion of door frame. Gusset holes should align with screw holes on the frame. Secure using flat head screws.

MODEL A B 36" 37"±1/4" 34"±1/4" 42" 43"±1/4" 34"±1/4" 50" 51"±1/4" 34"±1/4"

Figure 27 - Assembling Door Frame

Figure 28 - Installing Door Frame

Page 24 of the FMI WCM-42G user manual — Figure 30 - Installing Bottom Door Frame
Page 24 · click to enlarge
Page 24

Glass Door Installation

door frame MODELS BDMO36E/G/C, BDMO42E/G/C AND BDMO50E/G/C

Installing glass doors Spring clips have been installed but some adjustments may be needed. Install the doors using the following steps: 1. With bifold doors completely folded, insert bottom pivot pin into pivot hole located near bottom corner of front face opening and swing door to vertical position making sure top pins slide into door track. Door is installed when top door pin snaps into spring clip. 2. Repeat step 1 for remaining door. If you find the doors do not close properly or do not appear level or straight, proceed with section on door adjustment,

Installation 1. Remove screws from smoke shelf (see Figure 29). 2. Mount top door frame and secure with screws provided (see Figure 29). 3. Place bottom door frame on top of ash lip at front of fireplace (see Figure 30). 4. Secure bottom door frame to brick with two hex screws provided as shown in Figure 31 using a 7/16" open end or adjustable wrench.

FMI WCM-42G — door frame MODELS BDMO36E/G/C, BDMO42E/G/C AND BDMO50E/G/C diagram (page 24)
Fig. 28 · door frame MODELS BDMO36E/G/C, BDMO42E/G/C AND BDMO5…

Fold Door and Slide Top Pins Into Track

FMI WCM-42G — door frame MODELS BDMO36E/G/C, BDMO42E/G/C AND BDMO50E/G/C diagram (page 24)
Fig. 29 · door frame MODELS BDMO36E/G/C, BDMO42E/G/C AND BDMO5…

Insert Pin into Spring Clip

Insert Bottom Pivot Pin into Hole

Figure 31 - Installing Bi-Fold Doors

Door Adjustment Remove doors and slightly loosen lower pivot clips and upper spring clips. Replace doors and fully close them. Use 1/8" shims (any material) to level doors. Once proper setting is achieved, carefully open doors enough so that you can access spring clips with a phillips screwdriver. Tighten screws. See Figure 32.

FMI WCM-42G — Figure 31 - Installing Bi-Fold Doors diagram (page 24)
Fig. 30 · Figure 31 - Installing Bi-Fold Doors

Figure 30 - Installing Bottom Door Frame

Spring Clip · Pivot Hole

Page 25 of the FMI WCM-42G user manual — Figure 33 - Bi-Fold Glass Doors
Page 25 · click to enlarge
Page 25

Operation and Maintenance Guidelines

Cleaning Glass Clean glass with any commercial glass cleaner or soap and water. Do not use any abrasive material to clean glass. Do not clean glass with any cool water if glass is still hot from the fire and smoke. A gas line or gas log lighter may be installed for the purpose of installing a vented or vent- free decorative gas appliance incorporating an automatic shutoff device and complying with the Standard for Decorative Gas Appliances for Installation in Vented Fireplaces, ANSI Z21.60 or American Gas Association draft requirements for Gas Fired Log Lighters for Wood Burning Fireplaces, Draft NO. 4 dated August, 1993. If you wish to install an unvented (vent-free) gas log set, only unvented gas log sets which have been found to comply with the standard for unvented room heaters, ANSI Z21.11.2 are to be installed in this fireplace.

Glass Doors Glass doors are optional with the fireplace. When fireplace is in operation, doors must be fully opened or fully closed position only or a fire hazard may be created (see Figure 33). A fireplace equipped with glass doors oper- ates much differently than a fireplace with an open front. A fireplace with glass doors has a limited amount of air for combustion. Excessive heat within the fireplace can result if too large a fire is built or if combustion air gate is not completely open. The following tips should be followed to assure that both the fireplace and glass door retain their beauty and function properly. Both the flue damper and glass doors must be fully opened before starting fire. This will provide sufficient com- bustion air and maintain safe temperatures in firebox. IMPORTANT: The glass must be allowed to warm slowly and evenly. The tempered glass will withstand a gradual temperature rise to 550° F, which is more than a normal fire will generate. Such materials as pitch/wax laden logs, very dry mill end lumber and large amounts of paper or cardboard boxes can create an excessively hot fire and should not be burned in this fireplace. Always keep the fire well back from the doors and never allow flames to contact the glass.

Figure 33 - Bi-Fold Glass Doors

Show 4 more labels / short text on this page
Doors Fully Closed · Fireplace Front · Doors Fully Opened · Fireplace Front
Page 26 of the FMI WCM-42G user manual — Figure 35 - Outside Air Kit Lever
Page 26 · click to enlarge
Page 26

Operation and Maintenance Guidelines

ContinuedDE

outside air and damper handle operation The damper handle, which opens and closes the damper blade, is located in the upper front face of the fireplace. Pushing the handle for- ward and up through the keyway slot will free damper blade to automatically open. Pushing the handle forward and down will lock damper blade closed (see Figure 34).

The outside air kit lever is located at the left and right hand sides of fireplace (see Figure 35). Lifting lever up will free the outside air door to open. Pulling lever down will lock the door.

Open Position Closed Position

Figure 35 - Outside Air Kit Lever

Figure 34 - Operating Damper Handle

Show 4 more labels / short text on this page
Damper Weight · To Close Damper · Damper Weight · To Open Damper
Page 27 of the FMI WCM-42G user manual — Replacement Parts
Page 27 · click to enlarge
Page 27

Technical Service

You may have further questions about in- stallation, operation, or troubleshooting. If so, contact FMI PRODUCTS, LLC at 1-866-328-4537.

When calling please have your model and se- rial numbers of your heater ready. You can also visit our web site at www.fmiproducts.com

Replacement Parts

If this product is missing a part or has a broken component, please do not return it to the store. Call FMI PRODUCTS, LLC at 1-866-328-4537 to answer questions and replace parts under warranty. Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.

When calling or writing, please have your model and serial numbers of your fireplace ready. Model and serial number information are in the fireplace's rating plate located on the fireplace bottom. You can access the rating plate by lift- ing out the ash brick within hearth panel and removing the ash dump box.

Page 28 of the FMI WCM-42G user manual — Models (V)Gm36(Sr,SI,HR,HI), (V)Gm42(Sr,SI,HR,HI), (V)Gm50(Sr,SI,HR,HI), WCM-36G, WCM-42G, WCM-50G
Page 28 · click to enlarge
Page 28

Parts

Models (V)Gm36(Sr,SI,HR,HI), (V)Gm42(Sr,SI,HR,HI), (V)Gm50(Sr,SI,HR,HI), WCM-36G, WCM-42G, WCM-50G

FMI WCM-42G — Models (V)Gm36(Sr,SI,HR,HI), (V)Gm42(Sr,SI,HR,HI), (V)Gm50(Sr,SI,HR,HI), WCM-36G, WCM-42G, WCM-50G diagram (page 28)
Fig. 31 · Models (V)Gm36(Sr,SI,HR,HI), (V)Gm42(Sr,SI,HR,HI), (…
Page 29 of the FMI WCM-42G user manual — (V)GM36, WCM-36G
Page 29 · click to enlarge
Page 29

Parts This list contains replaceable parts used in your firebox. When ordering parts, follow the instructions listed under Replacement Parts on page 33 of this manual.

(V)GM36, WCM-36G

(V)GM42, WCM-42G

(V)GM50, WCM-50G

  • KEY NO. PART NO. DESCRIPTION QTY. 1 ** Face Assembly
  • 1 2 ** Firebox Bottom Assembly
  • 1 3 ** Firebox Bottom
  • 1 4 120826-01 Hearth Brick Panel, 36"
  • 1 120826-02 Hearth Brick Panel, 42"
  • 1 120826-03 Hearth Brick Panel, 50"
  • 1 5 ** Firebox Surround
  • 1 6 ** Outer Dome Assembly
  • 1 7 ** Insulation Pan Support
  • 1 8 ** Insulation Pan
  • 1 9 ** Top Insulation
  • 1 10 110285-03 Fireplace Top Assembly, 36"
  • 1 110285-02 Fireplace Top Assembly, 42"
  • 1 110285-01 Fireplace Top Assembly, 50"
  • 1 11 23490SA Standoff
  • 4 12 ** Fireplace Surround Assembly
  • 1 13 109720-02 Clearance Spacer
  • 6 14 117891-01 Fireplace Handle Bracket
  • 4 15 20042 Outside Air Cover Plate
  • 2 16 21171 Gas Conduit Cover
  • 4 17 109752-01 Conduit One
  • 2 18 109752-02 Conduit Two
  • 2 19 109726-01 Air Duct
  • 6 20 ** Heat Shield Support
  • 1 21 123298-01 Ash Box Assembly
  • 1 22 ** Ash Box Ring
  • 1 23 ** Hearth Support Brace
  • 1 24 ** Inner Dome Assembly
  • 1 25 ** Smoke Shield
  • 1 26 ** Damper Control Bracket
  • 1 27 ** Air Kit Door Assembly, Right
  • 1 28 ** Air Kit Door Assembly, Left
  • 1 29 109457-03 Screen
  • 2 109457-02 Screen
  • 2 109457-01 Screen
  • 2 30 20806 Screen Rod
  • 2 110146-03 Screen Rod
  • 2 110146-02 Screen Rod
  • 2 31 109496-03 Grate
  • 1 109496-02 Grate
  • 1 109496-01 Grate
  • 1 PARTS AVAILABLE NOT SHOWN see page 36 Brick Panel Assemblies with Brick

• • • 1

Housings (1 each, right, left, rear)

** Not a field replaceable part.

Page 30 of the FMI WCM-42G user manual — MK-36SS-(R)(I)
Page 30 · click to enlarge
Page 30

Parts

Models (V)Gm36(Sr,SI,HR,HI), (V)Gm42(Sr,SI,HR,HI), (V)Gm50(Sr,SI,HR,HI) This list contains replaceable parts used in your firebox. When ordering parts, follow the instructions listed under Replacement Parts on page 33 of this manual.

(V)GM36H(R)(I)

(V)GM36S(R)(I)

(V)GM42H(R)(I)

(V)GM42S(R)(I)

(V)GM50H(R)(I)

(V)GM50S(R)(I)

All parts are Housing Panel Assemblies. For Brick part numbers see pages 15 thru 27.

  • PART NO. DESCRIPTION QTY. 122317-02 36" Full Stack Left
  • 1 122319-02 42" Full Stack Left
  • 1 122321-02 50" Full Stack Left
  • 1 122323-02 36" Full Herringbone Left
  • 1 122327-02 42" Full Herringbone Left
  • 1 122327-02 50" Full Herringbone Left
  • 1 122317-01 36" Full Stack Right
  • 1 122319-01 42" Full Stack Right
  • 1 122321-01 50" Full Stack Right
  • 1 122323-01 36" Full Herringbone Right
  • 1 122325-01 42" Full Herringbone Right
  • 1 122327-01 50" Full Herringbone Right
  • 1 122354-01 36" Full Stack Rear
  • 1 122354-02 42" Full Stack Rear
  • 1 122354-03 50" Full Stack Rear
  • 1 122356-01 36" Full Herringbone Rear
  • 1 122356-02 42" Full Herringbone Rear
  • 1 122356-03 50" Full Herringbone Rear

MK-36SS-(R)(I)

MK-36SH-(R)(I)

MK-42SS-(R)(I)

MK-42SH-(R)(I)

MK-50SS-(R)(I)

MK-50SH-(R)(I)

  • PART NO. DESCRIPTION QTY. 120842-01 36" Split Stack Left
  • 1 120842-02 42" Split Stack Left
  • 1 120842-03 50" Split Stack Left
  • 1 120845-01 36" Split Herringbone Left
  • 1 120845-02 42" Split Herringbone Left
  • 1 120845-03 50" Split Herringbone Left
  • 1 120843-01 36" Split Stack Right
  • 1 120843-02 42" Split Stack Right
  • 1 120843-03 50" Split Stack Right
  • 1 120846-01 36" Split Herringbone Right
  • 1 120846-02 42" Split Herringbone Right
  • 1 120846-03 50" Split Herringbone Right
  • 1 120844-01 36" Split Stack Rear
  • 1 120844-02 42" Split Stack Rear
  • 1 120844-03 50" Split Stack Rear
  • 1 120847-01 36" Split Herringbone Rear
  • 1 120847-02 42" Split Herringbone Rear
  • 1 120847-03 50" Split Herringbone Rear
Page 31 of the FMI WCM-42G user manual — Optional Outside Air Kit for Sidewall Installation - AK4
Page 31 · click to enlarge
Page 31

Accessories

Ember Protector - 20093

BDMO36E - 36" Ebony BDMO36G - 36" Pewter BDMO36C - 36" Oiled Bronze BDMO42E - 42" Ebony BDMO42G - 42" Pewter BDMO42C - 42" Oiled Bronze BDMO50E - 50" Ebony BDMO50G - 50" Pewter BDMO50C - 50" Oiled Bronze

Optional Outside air kit for floor installation - ak4f

Double Wall Pipe - 12-12DM, 18-12DM, 24-12DM, 36-12DM, 48-12DM, 12-12HT, 18-12HT, 24-12HT, 36-12HT and 48-12HT

Optional Outside Air Kit for Sidewall Installation - AK4

Storm Collar - SC2-1

30° Offset and Return 30E-12DM and 30E-12HT

Firestop Spacer - FS-10

Page 32 of the FMI WCM-42G user manual — Round ToP TErminations RLT-12D and RLT-12HT
Page 32 · click to enlarge
Page 32

Replacement and Accessory Parts

Roof Flashing V6F-10DM - 0 to 6/12 Pitch V12F-10DM - 6/12 to 12/12 Pitch

Round ToP TErminations RLT-12D and RLT-12HT

SQUARE CHASE-TOP TERMINATION - STL-12D AND STL-12DMP BLACK

Page 33 of the FMI WCM-42G user manual — _____________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________
Page 33 · click to enlarge
Page 33

NOTES

Page 34 of the FMI WCM-42G user manual — 36" FULL HERRINGBONE BRICK MATRIX
Page 34 · click to enlarge
Page 34

2701 S. Harbor Blvd. Santa Ana, CA 92704

122271-01 Rev. D 01/10

1-866-328-4537 www.fmiproducts.com

Ask about the FMI WCM-42G

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the FMI WCM-42G

Be the first to ask — other owners or our team will answer.

Original document

FMI WCM-42G manual PDF

40 pages·3.4 MB·Indoor Fireplace·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…