OWNER’S OPERATION AND INSTALLATION MANUAL
PFS ®
US C
m36e(b,h), m42e(b,h), VM36E(B,h) and vm42E(b,h)
m36eP(b,h), m42eP(b,h), VM36EP(B,h) and vm42EP(b,h)
FOR YOUR SAFETY — Do not store or use gasoline or any other flammable
vapors or liquids in the vicinity of this or any other appliance. — WHAT TO DO IF YOU SMELL GAS :
fied installer, service agency or the gas supplier.
INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.
For more information, visit www.fmiproducts.com
Natural Gas models · PROPANE/LP Gas models


This fireplace is a vented product. This fireplace will not produce any gas leakage into your home if properly installed. This fireplace must be properly installed by a qualified service person. If this unit is not properly installed by a qualified service person, gas leakage can occur. Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness or nausea. If you have these signs, the fireplace may not have been installed properly. Get fresh air at once! Have fireplace inspected and serviced by a qualified service person. Some people are more affected by carbon monoxide than others. These include pregnant women, people with heart or lung disease or anemia, those under the influ ence of alcohol and those at high altitudes. Propane/LP gas and natural gas are both odorless. An odor-making agent is added to each of these gases. The odor helps you detect a gas leak. However, the odor added to these gases can fade. Gas may be present even though no odor exists. Make certain you read and understand all warnings. Keep this manual for reference. It is your guide to safe and proper operation of this fireplace.

11. Keep the area around your fireplace clear of combustible materials, gasoline and other flammable vapor and liquids. Do not run fireplace where these are used or stored. Do not place items such as clothing or decorations on or around fireplace. 12. Do not use this fireplace to cook food or burn paper or other objects. 13. Do not use any solid fuels (wood, coal, paper, cardboard, etc.) in this fireplace. Use only the gas type indicated on fire place nameplate. 14. This appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70 or the Canadian Electrical Code, CSA C22.1. 15. Do not obstruct the flow of combustion and ventilation air in any way. Provide
adequate clearances around air open ings into the combustion chamber along with adequate accessibility clearance for servicing and proper operation. 16. Do not install fireplace directly on carpet ing, vinyl tile or any combustible material other than wood. The fireplace must set on a metal or wood panel extending the full width and depth of the fireplace. 17. Do not use fireplace if any part has been exposed to or under water. Immediately call a qualified service person to arrange for replacement of the unit. 18. Do not operate fireplace if any log is broken. 19. Do not use a blower insert, heat exchang er insert or other accessory not approved for use with this fireplace. 20. Provide adequate clearances around air openings.
Introduction Models M36E(P)(B,H), VM36E(P)(B,H), M42E(P)(B,H) and VM42E(P)(B,H) are vented gas fireplaces that use an electronic control valve and electronic ignition system. A 6" B-Type venting system and a listed type vent cap are not supplied but are required for proper operation. See venting instructions on pages 9 and 10.
BEFORE YOU BEGIN Before beginning the installation of your appliance, read these instructions through completely. This FMI PRODUCTS, LLC appliance and its approved components are safe when installed according to this installation manual and are op erated as recommended by FMI PRODUCTS, LLC. Unless you use FMI PRODUCTS, LLC approved components tested for this appliance, YOU MAY CAUSE A FIRE HAZARD! The FMI PRODUCTS, LLC warranty will be voided by and FMI PRODUCTS, LLC disclaims any responsibility for the following actions: A) Modification of the appliance or any of the
Models M36E(B,H), VM36E(B,H), M42E(B,H) and VM42E(B,H) are factory equipped for use with natural gas and must be converted when intended for use with propane/LP gas. A respec tive model PCBE-36 or PCBE-42 conversion kit may be purchased for simple conversion to propane/LP gas. See Accessories, page 29.
components. B) Use of any component part not approved
by FMI PRODUCTS, LLC in combination with this appliance. C) Installation and/or operation in a manner
other than instructed in this manual. D) The burning of anything other than the type of
gas approved for use in this gas appliance.

The installation must conform with local codes or, in the absence of local codes, with the cur rent National Fuel Gas Code, ANSI Z223.1/ NFPA 54. This appliance complies with ANSI Z21.50/CSA 2.22.
The appliance and it’s individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa). The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5 kPa). For the purpose of input adjustment two pressure taps (for IN and OUT pressures) are provided on the gas control valve for test gauge connections to the appliance.
Selecting Location To determine the safest and most efficient location for your appliance, you must take into consideration the following guidelines: 1. The location must allow for proper clear ances (see Clearances, page 7). 2. Consider a location where heat output would not be affected by drafts, air con ditioning ducts, windows or doors. 3. A location that avoids the cutting of joists or roof rafters will make installation easier. Figure 1 shows a plan view of a few com mon locations. Flush installations are recommended where living space is limited or at a premium and since the space required to enclose the ap pliance would be located beyond an outside wall, this would also reduce the cutting of joists, roof rafters and such. Check local codes for any restrictions. Projected installations can extend any distance into the room. A projection may be ideal for a new addition on an existing, finished wall.
Corner installations make use of space that may not normally be used and provides a wider and more efficient range for radiant heat transference. Internal wall installations provide a discreet option for room separation and can also be ideal as an addition to an existing wall.
INTERNAL WALL INSTALLATION
FLUSH INSTALLATION
FULL PROJECTION INSTALLATION
Figure 1 - Possible Locations for
Installing Appliance


For Use With 6"Ø Type B-1 Vent Pipe Only
Figure 2 - Appliance Dimensions

CLEARANCES Minimum clearances to combustibles are: Back and Sides of Outer Surround 0" min. Drywall to Sides of Front Face (Nailing Flanges) 0" min. “B” Vent Surfaces 1" min. Ceiling to Opening 42" min. Floor 0" min. Perpendicular Wall See Figure 6
MANTEL CLEARANCES and Wall Details A combustible mantle shelf maybe installed a maximum 12" (22.9 cm) from wall. Figures 5 and 6 show the minimum allowable distances from various combustible mantle components in relation to fireplace opening.

Figure 5 - Mantel Clearances - Side View
Figure 3 - Minimum Clearances

1" (2.5 cm) Min. Clearance to "B" Vent's Outer Pipe

42" (106.7 cm) Min. Clearance from Opening to Ceiling 0" Clearance
Maintain 2" (5.1 cm) Min. Clearance to Transition Pipe as Measured at Outer Vent Collar
Required air spaces are indicated with an "*". Do not pack with insulation or any other material.
Figure 4 - Minimum Clearances
Figure 6 - Side Clearances - Top View

FRAMING 1. Frame appliance enclosure as illustrated in Figures 7 and 8. Note: If a wall covering is used to line enclosure, then all measurements must be from surface of covering. 2. Place appliance into framing and se cure. Note: If appliance is to be raised above floor level, a platform must be built to support appliance. 3. Install supply line to appliance using a 1/2" NPT black iron gas line terminating 2 5/16" above bottom of appliance. The gas line must be installed through lower left side access point or alternate access hole in the bottom of appliance (see Figure 19, page 13). 4. Repack insulation around gas line to cover any remaining openings in conduit sleeve. Prepare incoming gas line with teflon tape or pipe joint compound and hook up incoming gas line to flexible gas line. Note: If 1/2" NPT black iron pipe does not mate with fitting at the end of flexible gas line, remove fitting and replace with a 37 degree flare 3/4"-12, 1/2" NPT (female) fitting.
B
Figure 7 - Rough Opening for Installing
These Dimensions Allow for a 3/4" Clearance at Sides and Back of Fireplace. However, 0" Clearance is Permitted
B
3/4" Clearance Not Required at Nailing Flanges
Figure 8 - Corner Installation Guidelines
in Wall

Installing Transition Pipe and Starter Collar The transition pipe and starter collar shown in Figure 9 are supplied with fireplace, unat tached and ready for installation. Remove starter collar and set aside. Slide transition pipe over vent collar and attach with a mini mum of three screws. Replace starter collar over transition pipe and attach using four screws located on leg stands (five used on model M42E). To install B-vent piping, slide first piece of B-vent over transition pipe and attach with either a minimum of two screws or other means approved by the vent manu facturer.
Figure 9 - Installing Transition Pipe and
A B-type venting system must be connected to appliance for venting to the outside of building. The following section is provided as a guide to a standard B-type vent installation. Standing codes requirements concerning B- type vent installations may vary within your state, province or local codes jurisdiction. Therefore, it is recommended that you check with your local building codes for specific requirements or in absence of local codes, follow Section 7.0 of the current National Fuel Gas Code ANSI Z223.1/NFPA 54. This gas appliance must be vented to the outdoors only and may not be terminated into an attic space or into a chimney flue servicing a solid-fuel burning appliance. This appliance may be vented through a manufactured chimney system or a masonry chimney using a B-vent adapter or a chim ney liner system if all are listed, inspected and approved by local codes and/or building authorities. The examples shown in Figure 10, page 10 are typical of most B-vent installations and codes practices. Example 1: Shows the minimum allowable system height and lateral offset for a 60° or greater inclination. Code specifies that offsets at 60° or greater are considered horizontal and must follow the 75% rule for lateral to total vertical system height. Codes also al low only one offset in the total system when
at 60° or greater. The total vertical height in this example represents the minimum height of 8 feet and therefore the allowable lateral is 6 feet when the 75% rule applies. If the lateral length must exceed 75% then the system must be sized in accordance with the Category I venting tables. Example 2: Shows a multiple offset each at 45° of inclination. Multiple offsets are permit ted if they do not exceed 45° of inclination. The total lengths of the two offsets are not required to meet the 75% allowable rule. Example 3: Shows a single offset at 45° of inclination and therefore the lateral length at 10 feet of offset does not have to meet the 75% rule. In each case the offsets must be supported and firestops must be positioned wherever the vent must pass through a sub-floor, ceil ing joist or an attic overhang. The vent pipe must terminate vertically into a listed type vent cap and extend a sufficient height through an approved roof flashing, roof jack or a roof thimble. At all points the listed clearances must be maintained. Vent terminations must be located in ac cordance with height and proximity rules of NFPA No. 54. These rules apply to vents at 12" diameter or less and require a minimum height in accordance with the roof pitch and a minimum of 8 ft. distance from a vertical wall or obstruction (see Figure 11, page 10).


Figure 10 - Typical B-Vent Configuration
If venting horizontally through a side wall be comes necessary, a listed thimble approved for use with B-type vent must be used. Check with your local codes before venting through a side wall. Some codes areas allow the use of existing B-type vent systems if the system is at or above the recommended diameter of the flue, in this case 6". The flue connection must be made using listed B-type connectors and the existing system must be code inspected for damage and proper installation. It is not recommended that this appliance be common vented with an existing gas burning appliance. However, if it becomes necessary to common vent this appliance, the venting system must be sized and configured in ac cordance with the common venting guides Appendix G of the current National Fuel Gas Code ANSI Z223.1/NFPA 54. Note: Before connecting this appliance to an existing vent system or a common venting system consult with your local architect, plan ner or building official.
8 Ft. Min.
x Listed Gas Vent
Roof Pitch x/12 Listed Clearance
H (Min) Height From Roof
Figure 11 - B-Vent Terminations
Listed Vent Cap · Lowest Discharge Opening · Listed Vent Cap

CHECKING FOR PROPER VENTING After completing and checking electrical, gas and vent connections, follow the lighting instructions and allow the main burner to run for approximately 5 minutes. Hold a lighted match or cigarette near the top edge of fire place opening and play it along entire length of opening (see Figure 12). Proper venting should tend to draw the flame or smoke into the appliance. Improper venting or escaping of spillage of burned gas, is indicated when the match flickers or goes out. Smoke from a cigarette will also tend to disperse away from the appliance. If the appliance is found to be improperly venting, shut it off and notify your installer or a qualified service agency to inspect the venting system.

Check this area along entire top edge of fireplace opening. Smoke or flame should be drawn into appliance opening.
WALL SWITCH INSTALLATION The installation of a wall switch allows you to activate the gas control valve and turn the fireplace on and off. The wall switch is to be connected to the incoming 120 volt regular household wiring that supplies electricity to the fireplace. Refer to wiring diagram in this manual on page 18. optional Remote control INSTALLATION (model WRC) Note: If using optional wireless hand-held remote control, wall switch must be in the ON position to be operational. The remote control then becomes the switching mechanism for fireplace operation. 1. Remove front refractory access panel by lifting up and angling out of firebox open ing (see Figure 13). 2. The WRC model receiver does not require a battery. Receiver can be installed by plugging the short extension cord into fireplace receptacle. Plug receiver unit into extension cord. Plug ignition module plug into receiver unit (see Figure 14).


FMI PRODUCTS, LLC recommends that a black iron gas line be routed from the gas source, through a sediment trap (shown in Figure 18) and into appliance. Once con nected through appliance, a flexible gas line may be used for ease of installation to gas control valve (see Figure 19, page 13). Before connecting black iron gas line to inside of appliance a sediment trap must be included outside appliance between gas line and gas shutoff valve. It must extend down 3" beyond center of pipe. Prepare incoming black iron gas line with teflon tape or pipe joint com pound (Check with local building codes).
Battery Cover 12 Volt Battery
Pull to Remove Insulation Tab
Figure 15 - Installing Battery into Back of
Typical Exterior Wall Gas Shutoff Installation
Figure 16 - Manual Shutoff Valve
1/2" NPT Incoming Black
Alternate Gas Supply Through Sub-Floor
A manual shutoff valve has been included in the appliance’s gas supply system. You may consider installing an extra gas shutoff valve outside appliance’s enclosure (check with local codes) where it can be accessed more conveniently with a key through a wall as shown in Figure 16. In conformance with local codes, route a 1/2" NPT gas line to appliance through hole in left side of firebox or sub-floor as shown in Figure 17.
Figure 17 - Routing Incoming Gas Line
Incoming 1/2" Gas Line Permitted by Local Codes Sediment Trap (Not Supplied)

Figure 18 - Sediment Trap

Complete your gas installation by connect ing incoming gas line with flexible gas line. Secure tightly with wrench but DO NOT OVERTIGHTEN.
EMBER AND PAN MATERIAL placement 1. Open bag(s) of vermiculite and fill entire burner pan until burner tube is completely covered (see Figure 20). 2. Smooth pan material just even with edges of burner pan. 3. Remove ember material from bag and flatten small amounts into quarter size pieces and lay on top of surface of pan material (see Figure 21). 4. Place just enough to cover entire surface and leave about a 1/2" gap under lower grate members to allow air to flow (see Figure 22, page 14).
WARNING: All gas piping and connections must be tested for leaks after the installation is completed. After ensuring that gas valve is on, apply a commercial leak detection solution to all con nections and joints. If bubbles appear, leaks can be detected and corrected. Do not use an open flame for leak testing and do not operate any appliance if a leak is detected.
Flexible Gas Line Do NOT Kink
Red Surface Indicates For Propane/LP Use Only

Figure 19 - Connecting Flexible Gas Line to Millivolt Valve

Vermiculite (Pan Material) Grate

Figure 20 - Fill Entire Burner Pan with
Figure 21 - Ember Material on Surface of


Pan and Ember Material

0.5"
Figure 22 - Pan and Ember Material
LOG PLACEMENT For Models M36E, M36EP, VME36 and VM36EP 1. Place small front right log (log 1) on right front of grate as shown in Figure 23. 2. Place large back log (log 2) onto grate making sure notches rest over grate as shown in Figure 23. 3. Place log 3 into notch on log 2, resting front end on top of log 1 (see Figure 24). 4. Place upper end of log 4 into notch on log 2 as shown in Figure 24. Rest lower end of log 4 onto middle grate finger as shown in Figure 25. 5. Place upper end of log 5 into notch on left of log 2 (see Figure 25). Rest lower end of log 5 on grate as shown in Figure 26. 6. Insert lower end of log 6 between first two grate fingers as shown in Figure 26 and position upper end of log 6 into notched area on front of log 2 as shown in Figure 26. As an option to enhance the look of the hearth, you may place lava rock provided around front and sides of burner.
Figure 24 - Installing Logs 3 and 4


Figure 26 - Logs Installed for M36, M36P,
Figure 23 - Installing Logs 1 and 2
VM36 and VM36P Models

LOG PLACEMENT For Models M42E, M42EP, VME42 and VM42EP 1. Place large back log (log 1) onto grate making sure notches rest over grate (see Figure 27). 2. Insert lower end of log 2A between first two grate fingers and position upper end into notch on front of log 1. See Figure 27. Place log 2B on front right side of grate as shown in Figure 27. 3. Place log 3 into notch on top left of log 1, resting lower end on left two grate fingers (see Figure 28). 4. Place upper end of log 4 into notch on log 1 as shown in Figure 28. Rest lower end of log 4 on the middle grate finger as shown in Figure 29.
5. Place upper end of log 5 into notch on top inner right of log 1 (see Figure 29). Rest lower end of log 5 on middle grate finger as shown in Figure 30. 6. Place log 6 into notch on top right of log 1 (see Figure 29). Rest lower end of log 6 on top of log 2B (see Figure 30). As an option to enhance the look of the hearth, you may place lava rock provided around front and sides of burner pan.


Figure 27 - Installing Logs 1, 2A and 2B
Figure 29 - Installing Logs 5 and 6


Figure 30 - Logs Installed for M42E, M42EP, VM42E and VM42EP Models
Figure 28 - Installing Logs 3 and 4

COMBUSTION AIR KIT MODEL AK4 (OPTIONAL) The outside air kit may be installed on the left side of fireplace only. The vent can be installed through any outside wall a minimum of three feet below fireplace termination cap. The handle to operate damper door for outside air inlet will be located inside left “screen pocket” of firebox (see Figure 31). Pull handle to open or push to close.
Note: Glass door may be heavy for some individuals. If this is the case, please request help if needed. The M36E, VM36E, M42E and VM42E B- vent fireplaces are approved for use with optional bi-fold glass doors (see Accessories, page 29). Glass panels may be ordered and installed anytime after fireplace installation is complete. Follow these steps to install left and right panels: 1. With handle at the bottom, completely fold panel on its hinges. 2. With handle facing center of firebox open ing, insert lower pivot pin on glass door panel into hole in pivot plate on bottom edge of fireplace opening (see Figure 33). 3. Keeping folded door tilted, slide upper two pins into guide track found under upper facial edge of firebox opening. 4. Tilt glass assembly fully vertical until outer pivot pin snaps into mounting hole in up per spring clip (see Figure 33). 5. Once top and bottom pins are secured, unfold door into the closed position.
Figure 31 - Air Kit Handle Location
APPLIANCE ENCLOSURE Before finishing enclosure around appliance, inspect all joints around outer surround. Any gaps between nailing flanges and framing should be sealed with noncombustible insula tion or caulking. If appliance is mounted on a raised platform, it must be a continuous surface and not on blocks without a solid surface. This will pre vent entry of cold air by means of conduction through the total bottom of appliance (see Figure 32).
Spring Clip Insert Pin Into Spring Clip
Slide Top Pin Into Door Track
Insert Bottom Pivot Pin Into Pivot Plate and Swing Door Into Vertical Position
Caulk Here Pack Insulation
Figure 32 - Sealing Between Appliance
Figure 33 - Installing Optional Glass

Figure 34 - Adjusting Glass Doors
Fold Bi-Fold Door After Releasing Spring Clip and Slide Door Out of Upper Track
Press Spring Clip to Release Pivot Pin
The doors may be removed for replacement or cleaning as follows: 1. Partially open door and press up on upper spring clip with a screw driver until outer top pivot pin is free of clip. 2. Fully fold frame assembly and slide upper edge towards center of firebox opening until guide pins are free of frame rail (see Figure 35).
Remove Bottom Pin From Pivot Plate While Sliding Door Out of the Upper Track
Figure 35 - Removing Glass Doors
Opening Vent Damper Vent damper must be locked in the full open position before operating fireplace. If vent damper is not open, fireplace will not light.
CLOSE OPEN
IN THE FULL OPEN POSITION TO OPERATE THE APPLIANCE
Figure 36 - Opening Vent Damper

A. This appliance has a pilot which must
be lighted by hand. When lighting the pilot, follow these instructions exactly. B. BEFORE LIGHTING smell all around
the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a quali fied service technician or gas supplier. Force or attempted repair may result in a fire or explosion. D. Do not use this appliance if any part
has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.
Figure 37 - Turning Equipment Shutoff
Valve to the OFF Position
Equipment Shutoff Valve · Adjustment Screw

TO APPLIANCE 1. Turn off wall switch. 2. Turn off all electric power to appliance if service is to be performed. 3. Fully open glass doors if installed. 4. Remove front hearth brick and control access panel. 5. Turn gas control knob clockwise to OFF. Do not force. 6. Replace front refractory brick access panel. 7. Fully close glass doors if installed.

OPERATION Note: The WRC receiver and hand-held re mote control kit must be purchased separately (see Accessories, page 29). Follow installa tion instructions on page 10.
Figure 38 - Pilot
Check pilot flame pattern and burner flame patterns often.

Figure 39 - Correct Pilot Flame Pattern

BURNER FLAME PATTERN Burner flames will be steady, not lifting or floating. Flames should go up through the middle of logset. Flames should not "spill" to the edges of pan or sides of logset.
Figure 40 - Typical Flame Pattern
Ignitor · Sensing Rod · Ignitor/ Sensor

WARNING: Installation and repair should be done by a quali fied service person. The appli ance should be inspected before each use and at least annually by a qualified service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding mate rial, pet hair, etc. It is imperative that the control compartments, burners and circulating air sys tem be kept clean.
Parts Under Warranty Contact authorized dealers of this product. If they can’t supply original replacement part(s), call FMI PRODUCTS, LLC at 1-866- 328-4537.

WALL SWITCH
(NOT SUPPLIED)
SUPPLY
ON
OFF
BLACK
120V AC INCOMING
IGN
WHITE
VENT SAFETY SHUTOFF SWITCH MANUAL DAMPER
MODEL SP745 IGNITION CONTROL
GREEN
OR BREAKER) (FUSE BOX
PV GND PV/MV TR MV TH
EV1
BLACK
GREEN
SWITCH
WHITE
ELECTRICAL RATING:
120v, 60Hz, 0.7A
24V AC
STEP DOWN TRANSFORMER
120V AC
OPTIONAL REMOTE CONTROL
TO GAS LINE
BURNER
Technical Service You may have further questions about instal lation, operation, or troubleshooting. If so, contact FMI PRODUCTS, LLC at 1-866-328- 4537. When calling please have your model and serial numbers of your heater ready. You can also visit FMI PRODUCTS, LLC’s web site at www.fmiproducts.com.
Pilot Burner · Pilot Gas Line · Robertshaw

Troubleshooting Note: Before troubleshooting the system, make sure the gas shutoff valve is ON. The two most common causes of a malfunctioning gas appliance are: 1. Loose wiring connections 2. Construction debris clogging the pilot and/or gas control valve filter
POSSIBLE CAUSE
REMEDY
Ignitor will not spark or pilot will not light
1. Check to see if you have gas supply and that equipment shutoff valve is opened 2. Repeat lighting procedure several times to purge all air out of lines. If after repeated attempts appliance does not light, call for qualified service and repair 3. Remove debris and dirt, inspect and clean any other possible obstructions 4. Contact your gas supplier to check pressure 5. Have a qualified technician replace pilot line 6. Replace control valve (re fer to Replacement Parts, page 20) 7. Check that main power is on and that all wire connec tions are made correctly to ignition model (see Wiring Diagram, page 21). Check for 24 VAC at the secondary side of transformer. If 24 VAC is present and module does not operate, have module replaced otherwise have transformer replaced 8. Open vent damper until fully locked in OPEN position
Pilot will not stay lit
No gas to burner, although wall switch and valve are set to the ON position

REMEDY
Fireplace produces a clicking/ ticking noise just after burner is lit or shut off
Fireplace produces unwanted odors
Gas odor even when gas control valve is off
Gas odor during combustion
Dark residue on logs or inside of fireplace



Parts This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 20 of this manual.
KEY NO.
M42E(P)(B,H) VM42E(P)(B,H) DESCRIPTION QTY 1 14153 14153 Micro Switch 1 2 109098-01 109098-01 Wire Harness 1 3 108863-01 108863-01 24" Supply Connect Plug 1 4 108864-01 108864-01 Strain Relief 1/2" Bushing 1 5 106642-01 106642-01 Air Rod Retainer 1 6 106643-01 106643-01 Damper Rod Retainer 1 7 106651-01 107805-01 Panel Closure 2 8 14129 14129 Transformer 1 9 11201 11201 Nut, #8-32 4 10 106657-02 107811-02 Air Separator 1 11 11408 11408 Bushing 2 12 See page 26 Left Refractory 1 13 See page 26 Right Refractory 1 14 See page 26 Rear Refractory 1 15 See page 26 Bottom Rear Refractory 1 16 See page 26 Bottom Front Refractory 1 17 11186 11186 Scew, #8-32 2 18 20088 20088 Door Stop 1 19 106691-01 107839-01 Screen Rod 2 20 11109 11109 Screw, #8-32 x 1/2" 2 21 106699-01 106699-01 Transition 6" B-Vent Collar 1 22 106703-01 106703-01 Air Kit Door Assembly 1 23 11107 11107 Screw, #10-32 x 1/4" 4 24 106948-02 107823-02 Smoke Deflector 1 25 11165 11165 Screw, #10 x 5/8" 2 26 107796-01 107796-02 Grate Assy 1 27 107742-01 107742-02 Burner Pan 1 28 107795-01 107831-01 Burner Tube 1 29 107748-01 107748-01 Burner Brckt 1 30 107985-01 107985-02 Pilot Shield 1 31 901681-01 901681-01 Burner Clamp 1 32 11209 11209 Nut, #10-24 1 33 11147 11147 Screw, #10-24 x 1/2 1 34 901066-01 901066-01 Brass Air Mixer (NG) 1 901066-02 901066-02 Brass Air Mixer (LP) 1 35 901064-03 901064-08 Orifice (NG) 1 901065-13 901065-08 Orifice (LP) 1 36 108866-01 108866-01 Pilot (NG) 1 108866-02 108866-02 Pilot (LP) 1 37 108867-01 108867-01 Pilot Orifice (NG) 1 108867-02 108867-02 Pilot Orifice (LP) 1 38 11102 11102 Screw, #8-32 x 3/8 2 39 14569 14569 Gas Control Valve (NG) 1 14570 14570 Gas Control Valve (LP) 1 40 107741-01 107741-01 Valve Bracket 1 41 110286-01 110286-01 Ignition Module 1 42 111288-02 111288-02 Manual Valve w/ Flex Hose 1 43 22912 22924 Draft Diverter 1 44 108005-03 108005-03 Wire Harness 1 45 108005-02 108005-02 Wire Harness 1 46 11418 11418 Push-On Nut 2 47 12105 107840-01 Screen 2 48 14123 14123 Strain Relief 1 49 14574 106543-01 Limit Switch 1 50 20280 20280 Top Spacer 4 51 20023 20023 Starter Collar 1 52 20027 20027 Brick Liner Retainer 2 53 20042 20042 Air Kit Cover 1 54 20090 20090 Spring Clip 2 55 20089 20089 Pivot Clip 2 PARTS AVAILABLE NOT SHOWN 901157-01 901157-01 Lava Rock 1

Parts This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 20 of this manual.

KEY NO.
M42(B,H) VM42(B,H) DESCRIPTION QTY 12 106658-02 107812-02 Left Refractory, Std. Brick (M36EB/ME42B) 1 108164-02 108169-02 Left Refractory, Herringbone (M36EH/M42EH) 1 106658-01 107812-01 Left Refractory, Std. Brick (VM36EB/VM42EB) 1 108164-01 108169-01 Left Refractory, Herringbone (VM36EH/VM42EH) 1 13 106659-02 107814-02 Right Refractory, Std. Brick (M36EB/M42EB) 1 108165-02 108170-02 Right Refractory, Herringbone (M36EH/M42EH) 1 106659-01 107814-01 Right Refractory, Std. Brick (VM36eB/VM42EB) 1 108165-01 108170-01 Right Refractory, Herringbone (VM36EH/VM42EH) 1 14 106660-02 107816-02 Rear Refractory, Std. Brick (M36EB/M42EB) 1 108166-02 108171-02 Rear Refractory, Herringbone (M36EH/M42EH) 1 106660-01 107816-01 Rear Refractory, Std. Brick (VM36EB/VM42EB) 1 108166-01 108171-01 Rear Refractory, Herringbone (VM36EH/VM42EH) 1 15 106661-02 107818-02 Bottom Rear Refractory, Std. Brick (M36/ME42, M36B/M42EB) 1 108167-02 108172-02 Bottom Rear Refractory, Herringbone (M36H/M42H) 1 106661-01 107818-01 Bottom Rear Refractory, Std. Brick (VM36E/VM42E, VM36EB/VM42EB)
108167-01 108172-01 Bottom Rear Refractory, Herringbone (VM36EH/VM42EH) 1 16 106662-02 107820-02 Bottom Front Refractory, Std. Brick (M36E/M42E, M36EB/M42EB)
108168-02 108173-02 Bottom Front Refractory, Herringbone (M36EH/M42EH) 1 106662-01 107820-01 Bottom Front Refractory, Std. Brick (VM3E6/VM42E, VM36B/VM42B)
108168-01 108173-01 Bottom Front Refractory, Herringbone (VM36EH/ VM42EH) 1


KEY NO. PART NO. DESCRIPTION QTY. - 107999-01 Log Set 1 108724-01 Right Front 9" Split Log 1 2 901098-01 Rear Log 1 3 108720-01 Top Right Log - 11 3/4" 1 4 108721-01 Top Right Log - 16" 1 5 108722-01 Top Left Log - 13 1/2" Y-Log 1 6 108723-01 Top Left Log - 11" 1



KEY NO. PART NO. DESCRIPTION QTY. - 107999-02 Log Set 1 901098-02 Rear Log 1 2A 108723-01 Left Front Log - 11" 1 2B 108839-01 Right Front Log - 15 3/4" Round 1 3 108722-01 Top Left Log - 13 1/2" Y-Log 1 4 108838-01 Inside Top Left Log - 15 3/4" Split 1 5 108721-01 Inside Top Right Log - 16" 1 6 108720-01 Top Right Log - 11 3/4" 1


Accessories Notice: All accessories may not be available for all fireplace models. Purchase these accessories from your local dealer. If they can not supply these accessories call FMI PRODUCTS, LLC at 1-866-328-4537 for information. You can also write to the address listed on the back page of this manual.
Air kit - AK4 Optional kit helps offset the negative pressure often existing in today's tightly constructed homes.
Blower Kit BK - Squirrel Cage Blower With Speed Control
Perimeter Trim PT36 - 36", Black PT36B - 36", Brushed Brass PT36P - 36", Platinum PT42 - 42", Black PT42B - 42", Brushed Brass PT42P - 42", Platinum
Remote Control Kits WRC - Standard On/Off Electronic Remote Control Kit
Extruded aluminum bi-fold glass doors BD36 - 36" Black Finish BD36B - 36" Brushed Brass Finish BD36P - 36" Platinum Finish BD42 - 42" Black Finish BD42B - 42" Brushed Brass Finish BD42P - 42" Platinum Finish
Louver Trim Kit (Rolled Louvers Only) LT36B - 36", Brushed Brass LT36P - 36", Platinum LT42B - 42", Brushed Brass LT42P - 42", Platinum
Fixed glass doors FD36 - 36" Black Finish FD36B - 36" Brushed Brass Finish FD36P - 36" Platinum Finish FD42 - 42" Black Finish FD42B - 42" Brushed Brass Finish FD42P - 42" Platinum Finish
Face/Louver Panel Kits SP36, SP42 - Smooth Faced, Black SL36, SL42 - Stamped, Black RL36, RL42 - Rolled, Black FP36, FP42 - Filigree Panel, Black FP36B, FP42B - Filigree Panel, Brushed Brass FP36P, FP42P - Filigree Panel, Platinum
Brick Liner Kit (For M36(B,H), M36P(B,H), M42(B,H) and M42P(B,H) BL36 - 36" Refractory Standard Brick BL42 - 42" Refractory Standard Brick BL36H - 36" Refractory Herringbone Brick BL42H - 42" Refractory Herringbone Brick
FIRE CRACKLE - CF6-A Creates the sound of a real burning fire.
PROPANE/NATURAL GAS CONVERSION KIT PCBE-36 - Propane/LP Gas, Electronic Models NCBE-36 - Natural Gas - Electronic Models PCBE-42 - Propane/LP Gas, Electronic Models NCBE-42 - Natural Gas, Electronic Models
(For VM36(B,H), VM36P(B,H), VM42(B,H) and VM42P(B,H) BL36S - 36" Refractory Standard Brick BL42S - 42" Refractory Standard Brick BL36HS - 36" Refractory Herringbone Brick BL42HS - 42" Refractory Herringbone Brick



Model (located on product or identification tag)
Serial No. (located on product or identification tag)
Keep receipt for warranty verification.
New Products Standard Warranty: FMI PRODUCTS, LLC warrants this new product and any parts thereof to be free from defects in material and workmanship for a period of four (4) year from the date of first purchase from an authorized dealer provided the product has been installed, maintained and operated in accordance with FMI PRODUCTS, LLC’s warnings and instructions. For products purchased for commercial, industrial or rental usage, this warranty is limited to 90 days from the date of first purchase.
Factory Reconditioned Products Limited Warranty: FMI PRODUCTS, LLC warrants factory reconditioned products and any parts thereof to be free from defects in material and workmanship for 30 days from the date of first purchase from an authorized dealer provided the product has been installed, maintained and operated in accordance with FMI PRODUCTS, LLC’s warnings and instructions.
Terms Common to All Warranties The following terms apply to all of the above warranties: Always specify model number and serial number when contacting the manufacturer. To make a claim under this warranty the bill of sale or other proof of purchase must be presented. This warranty is extended only to the original retail purchaser when purchased from an authorized dealer, and only when installed by a qualified installer in accordance with all local codes and instructions furnished with this product. This warranty covers the cost of part(s) required to restore this product to proper operating condition and an allowance for labor when provided by a FMI PRODUCTS, LLC Authorized Service Center or a provider approved by FMI PRODUCTS, LLC. Warranty parts must be obtained through authorized dealers of this product and/or FMI PRODUCTS, LLC who will provide original factory replacement parts. Failure to use original factory replacement parts voids this warranty. Travel, handling, transportation, diagnostic, material, labor and incidental costs associated with warranty repairs, unless expressly covered by this warranty, are not reimbursable under this warranty and are the responsibility of the owner. Excluded from this warranty are products or parts that fail or become damaged due to misuse, accidents, improper installation, lack of proper maintenance, tampering, or alteration(s). This is FMI PRODUCTS, LLC’s exclusive warranty, and to the full extent allowed by law; this express war ranty excludes any and all other warranties, express or implied, written or verbal and limits the duration of any and all implied warranties, including warranties of merchantability and fitness for a particular purpose to four (4) year on new products and 30 days on factory reconditioned products from the date of first purchase. FMI PRODUCTS, LLC makes no other warranties regarding this product. FMI PRODUCTS, LLC’s liability is limited to the purchase price of the product, and FMI PRODUCTS, LLC shall not be liable for any other damages whatsoever under any circumstances including indirect, incidental, or consequential damages. Some states do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. For information about this warranty contact:
2701 S. Harbor Blvd. Santa Ana, CA 92704
108796-01 Rev. U 09/09
1-866-328-4537 www.fmiproducts.com