Models PG240, PAD240, PADC240, PAR230 Optical
in U.S.A.
PLEASE READ AND SAVE INSTALLER: Please leave this manual with the product.
© 2002 Maple Chase 110-666C
SMOKE ALARM DESCRIPTION Model GC240 Ionisation 230V AC smoke alarm with False Alarm Control Model I240C Ionisation 230V AC smoke alarm with 9V battery back-up and False Alarm Control Model IAR230C Ionisation 230V AC smoke alarm with recharge- able battery backup and False Alarm Control Model PG240 Optical 230V AC smoke alarm and False Alarm Control Model PAD240 Optical 230V AC smoke alarm with 9V & PADC240 battery back-up with False Alarm Control Model PAR230 Optical 230V AC smoke alarm with rechargeable battery back-up and False Alarm Control
PLEASE READ AND SAVE THESE
INSTRUCTIONS
Printed · !

It is recommended to achieve complete coverage protection by installing a smoke alarm in every room of your home.
At a minimum, smoke alarms shall be installed outside of each separate sleeping area in the immediate vicinity of the bedrooms and on each addi- tional storey of the family living unit including basements and excluding crawl spaces and unfinished attics. Any home requires a minimum of two smoke alarms.
FOR BEST PROTECTION, IT IS RECOMMENDED THAT YOU INSTALL A SMOKE ALARM IN EVERY ROOM
In addition, it is recommended that all smoke alarms be interconnected. Typical Efficiency Home (Apartment) •Install a smoke alarm on the ceiling or wall closest to the sleeping area. Install a smoke alarm with False Alarm Control in the kitchen/living area.
KITCHEN
AREA
LIVING
AREA
Typical Single Storey Home •Install a smoke alarm on the ceiling or wall inside each bedroom and in the hallway outside each separate sleeping area. If a bedroom area hallway is more than 9 m long, install a smoke alarm at each end.

BEDROOMBEDROOM
LIVING ROOM
BEDROOM

DINING
ROOM
FIREPLACE
BEDROOM
BEDROOM
Typical Two-Storey Home •Install a smoke alarm on the ceiling or wall inside each bedroom and in the hallway outside each separate sleeping area.

BEDROOM BEDROOM
If a bedroom area hallway is more than 9 m long, install a smoke alarm at each end. •Install a smoke alarm at the top of a first-to-second floor stairwell.
GARAGE
Key • Smoke Alarm ∆ Smoke Alarm with False Alarm Control

ACCEPTABLE HERE
NEVER HERE
TOP OF DETECTOR ACCEPTABLE HERE
SIDE WALL
SOFFIT
STUB WALL
1M
PEAKED CEILING
DO NOT install smoke alarms:
Near appliances or areas where normal combustion regularly occurs (kitchens, near boilers, hot water heaters). Use specialized smoke alarms with unwanted alarm control for these areas.
In areas with high humidity, like bathrooms or areas near dishwashers or washing machines. Install at least 3 metres away from these areas.
Near air returns or heating and cooling supply vents. The air could blow smoke away from the detector, interrupting its alarm.
In rooms where temperatures may fall below 5˚C (41˚F) or rise above 45˚C (113˚F).
In extremely dusty, dirty, or insect-infested areas. Loose particles interfere with smoke alarm operation.
WARNING: The smoke alarm, its associated supply and interconnect wiring must be installed in accordance with BS 7671 published by the Institution of Electrical Engineers. • Install smoke alarm on a wall, ceiling, standard electrical box, or surface mounting pattress. 1. Align mounting plate with mounting holes of standard electrical box or sur- face mounting pattress. For siting on wall or ceiling, use mounting plate as template to mark holes. Drill holes (for wall or ceiling only) and insert sup- plied screw plugs into holes until flush with wall or ceiling. 2. Secure mounting plate to electrical box, pattress, wall, or ceiling. (Diagram illustrates fixing mounting plate to electrical box.) 3. Connect blue wire from connector plug of smoke alarm to neutral (black or blue) mains power wire. 4. Connect brown wire from connector plug of smoke alarm to live (red or brown) mains power wire . 5. If interconnection is desired, connect orange wire from connector to interconnect wire between smoke alarms. See section, “Interconnecting Smoke Alarms.”

electrical tape and tuck into ceiling, wall, or pattress.
ELECTRICAL BOX OR PATTRESS
CEILING
CEILING
INTERLINK
INTERLINK
NEUTRAL
NEUTRAL
ORANGE BROWN LINE
BROWN LINE
ORANGE
BLUE
BLUE
BLUE
MODELS GC240, I240C, PG240, PAD240, PADC240
MODELS IAR230, PAR230,
IAR230C
Steps 6-9 for Models I240C, PAD240 and PADC240 ONLY: 6. Lift open battery pocket door. 7. Connect new 9-volt battery to battery connector inside battery pocket. BE SURE BATTERY IS SECURELY CONNECTED. Smoke alarm may beep briefly when battery is installed. 8. Close battery pocket door, snapping it into place. 9. Push button and hold button on front cover of smoke alarm for three (3) seconds. Smoke alarm should sound its alarm horn if battery is fit- ted correctly. 10. Attach connector plug to pins on back of smoke alarm. Plug will only fit one way and will snap into place. 11. Gently tug connector to be sure it is attached securely. 12. Position smoke alarm to mounting plate so that keyslot on side of smoke alarm is to left of tab on mounting plate. Turn clockwise to lock into place. NOTE: (For Models I240C, PAD240 and PADC240 only): Smoke alarm will not mount to plate if battery is not installed.
ORANGE ORANGE
NEUTRAL
RED OR BROWN
LINE
FOR INTERCONNECT: USE STANDARD 1.5MM 2 CABLE
RED AND GREEN LED
INDICATORS This smoke alarm features red and green LED indicators that can be seen through the Push-to-Test button or the LED lens above the test button. The LEDs indicate the following: GREEN LED ON — AC power is present. OFF — AC power is not present. RED LED Blinks once a minute — indicating normal operation. Blinks once a second — smoke alarm senses smoke and simul-
taneously sounds an audible alarm. Blinks once every 10 seconds — smoke alarm is quieting an unwanted
alarm. (Models GC240, I240C, PADC240, and IAR230C, PG240, PAR230.) (Interconnected system only): OFF — another smoke alarm in the network has sensed
smoke and is signalling this alarm.

FALSE ALARM CONTROL Models GC240, I240C, PADC240, PG240, PAR230 and IAR230C feature False Alarm Control that, when activated, quiets unwanted alarms for up to 15 minutes. To use the False Alarm Control: Press and release the test button during an unwanted alarm. The alarm should stop within ten seconds. This means the smoke alarm is in False Alarm Control. If the smoke alarm does not go into False Alarm Control and continues to sound its loud alarm horn, or if it initially goes into False Alarm Control then resounds the alarm, the smoke is too heavy and could be a dangerous situation – take emergency action.
Test all smoke alarms weekly by doing the following: 1. Check Push-to-Test button. A constant green light indicates the smoke alarm is receiving 230V AC, 50Hz power. A red flashing LED about once a minute verifies operation. For models I240C, PAD240, PADC240, IAR230C, and PAR230 the red flashing LED also verifies that a working battery is present.
sound an alarm within three seconds after any test button is pushed and the tested smoke alarm sounds.
being tested, the smoke alarm is sensing smoke. THE SOUND OF THE ALARM HORN REQUIRES YOUR IMMEDIATE ATTENTION AND ACTION.
MAINTENANCE AND CLEANING In addition to weekly testing, Models I240C, PAD240, and PADC240 also require periodic battery replacement. Regularly clean smoke alarm to remove dust, dirt, and debris.
which prevents dust and debris from damaging the unit during construction or remodeling. Remove dust cover before opera- tion. Alarm will not operate properly while covered. DANGER: ELECTRICAL SHOCK HAZARD. Turn off main
power at fuse box or consumer unit by remov- ing fuse or switching appropriate circuit breaker to OFF position before replacing bat- tery or cleaning smoke alarm.
replaced.
Always turn off power to smoke alarm before replacing battery. Replace battery at least once a year or immediately when the low battery signal sounds once a minute, even though the smoke alarm is receiving AC power. Use only the following batteries as replacements in this smoke alarm: Eveready 216, 522, 1222; Duracell MN 1604; or Ultralife U9VL-J
Replace only with the same or equivalent battery type recommended by the manufacturer. Discard used batteries safely according to manufacturer's instructions. WHENEVER THE BATTERY IS REPLACED, TEST THE ALARM FOR CORRECT OPERATION PUSHING THE TEST BUTTON.
BATTERY, EXCEPT AS SPECIFIED IN THIS MANUAL. DO NOT USE RECHARGEABLE BATTERIES. (For Models IAR230C and PAR230 only): NOTE: Rechargeable lithium batteries are permanently mounted and
sealed in the tamper-proof housing. These cells are designed to last the useful life of the smoke alarm.

1. Turn off power to smoke alarm at main service panel. 2. Insert a small screwdriver into the slot in the mounting plate. Depress locking tab with the screwdriver and turn smoke alarm counter-clock- wise to detach from mounting plate. 3. Gently pull down smoke alarm. Be careful not to separate wire con- nections. 4. Pull out power plug from back of smoke alarm. 5. From back of smoke alarm, lift tab to open battery pocket door. 6. Remove battery from pocket. Disconnect and discard drained battery from battery connector. 7. Connect a fresh, 9-volt battery to connector. The battery will fit only one way. Be sure battery connector is securely attached to battery ter- minals. Smoke alarm may sound a short beep when battery is installed. This is normal and means the battery is installed correctly. 8. Place battery into battery pocket. 9. Close battery pocket door. Push down until it snaps into place. 10. Press and hold test button. The alarm will sound if the battery is prop- erly connected and working. 11. Replace connector plug. Connector will “snap” into place. Gently tug connector to be sure it is attached properly. 12. Reattach smoke alarm to mounting plate by turning smoke alarm clockwise until it snaps into place. 13. Turn on power and test smoke alarm using test button.
alarm. THIS WILL VOID YOUR GUARANTEE.
Doing so will void your guarantee.
If smoke alarm is not operating properly, see “Troubleshooting”. If neces- sary and if still under guarantee, return smoke alarm to Sensotec. Pack it in a well-padded carton and send, postage prepaid to Sensotec address at the end of this manual. If the smoke alarm is no longer under guarantee, have a licensed electrician replace the smoke alarm immediately with a comparable Firex brand smoke alarm.
These guidelines will assist you in the event of a fire. However, to reduce the chance that fires will start, practice fire safety rules and prevent hazardous situations.
!

! · !

WARRANTY Maple Chase Company warrants to the original consumer purchaser each new smoke alarm to be free from defects in material and work- manship under normal use and service for a period of six (6) years in the United Kingdom and Republic of Ireland from date of purchase. Maple Chase Company agrees to repair or replace, at its option, any defective smoke alarm, provided that it is returned with postage pre- paid and with proof of purchase date to Maple Chase Company. This warranty does not cover damage resulting from accident, misuse or abuse or lack of reasonable care of the product. This warranty is in lieu of all other express warranties, obligations or liabilities. THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED TO A PERIOD OF SIX (6) YEARS FROM PURCHASE DATE. Some states do not allow limita- tions on how long an implied warranty lasts, so the above limitations may not apply to you. IN NO CASE SHALL MAPLE CHASE COMPA- NY BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAM- AGES FOR BREACH OF THIS OR ANY OTHER WARRANTY, EXPRESS OR IMPLIED, WHATSOEVER, EVEN IF THE LOSS OR DAMAGE IS CAUSED BY ITS NEGLIGENCE OR FAULT. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other legal rights which vary from state to state. Return units freight prepaid to your local reseller. For information on your local reseller in the U.K. and Republic of Ireland, contact:
Sensotec Europe Ltd. Unit 7, Bala Industrial Estate
Bala, Gwynedd LL23 7NL
United Kingdom Tel.: +44 (0) 1678 520022 Fax.: +44 (0) 1678 520689
Maple Chase 191 E. North Avenue Carol Stream, Illinois 60188 United States of America
©2002 Maple Chase 110-666C
Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| Smoke alarm does not sound when tested. NOTE: Push test but- ton for at least five (5) seconds while testing! | 1. Check that AC power is turned on. Green LED should be illuminated. 2. Turn off power. Remove smoke alarm from mounting plate and: a. check that connector plug is securely attached. b. check that battery is properly attached to connector. 3. Clean smoke alarm. | p.7 | |
| Smoke alarm beeps about once a minute. (Models I240C and PAD240 only) (Models IAR230C and PAR230) | 1. Turn off power and replace battery. See Battery Replacement” in the MAINTENANCE AND CLEANING section. 2. Clean smoke alarm. 3. Verify that unit has been under mains operation for a minimum of 2 full days. If the beeping persists after required charging period, return the unit for service. | p.7 | |
| Smoke alarm sounds unwanted alarms when residents are cooking, taking showers, etc. Interconnected smoke alarms do not sound when system is tested. | 1. Hire an electrician to move smoke alarm to a new location. See "SMOKE ALARM PLACEMENT" 1. Press and hold test button for at least three seconds after the first unit sounds. 2. Hire an electrician to ensure smoke alarms are properly connected. | p.7 |