Description
Item 243
The 243 Hearing Impaired Kit features a 406C 120V AC Smoke Alarm, 499C FireX® Relay Module, 240 strobe light (177 candela), and a wiring instruction sheet. The 406C Smoke Alarm has an 85 decibel horn, test switch and a lighted power/alarm LED indicator; the LED flashes once per minute to confirm AC power. When in alarm, the LED (406C Smoke Alarm) flashes rapidly once per second. The 240 strobe light utilizes a Xenon flash tube which generates a high-intensity light, visible from all sides of the lens. The 240 Remote Strobe is intended to provide a visible notification signal for the purpose of life safety and property protection.

Features and Benefits
Meet the growing demand for smoke alarms for the hearing impaired with this kit from FireX® alarms. Exceeds UL Standard 1971 “Signaling Devices for the Hearing Impaired” and ADA (American Disabilities Act) “Standard for Visual Alarms”. Allows for the remote placement of strobe light for maximum effectiveness. Each kit contains all of the components necessary to install a smoke alarm/signaling device ideally suited to the needs of the hearing impaired.
The 406C Smoke Alarm mounts to any single or 4” octagon junction box or square-to-round drywall ring and has 8” long pigtails with a Quick Connect harness for easy connection.
The 243 Hearing Impaired Kit is ideal for hotels, apartments, hospitals, rest homes or whenever visible alarms are required.
Installation of Smoke Alarm Kit KIT SMOKE RELAY STROBE 243 406C 499C 240 ULC ULC UL
This smoke alarm should be installed in accordance with the NFPA’s Standard 72 (National Fire Protection Association, Batterymarch Park, Quincy, MA 02269) and any local codes that apply. Use #18 AWG minimum solid or stranded wire. When interconnecting, maximum wire length between any two is 1,500 feet for #18 AWG or 4,000 feet for #14 AWG (20 OHMS loop resistance). DO NOT connect to any other type or model of heat or smoke alarm. Connect smoke to a single AC branch circuit. If local codes do not permit, be sure the neutral wire is common to both phases.
PRODUCT WEIGHT .590 kg. OPERATING TEMPERATURE 4° to 38°C INTERCONNECT QTY 6 ELECTRICAL RATING 120V AC, 60HZ, 50mA max ALARM POINT obs. 1.01 ± 0.37%/ft. HORN OUTPUT 85 decibels at 3.048 meters LISTING UL 217 and ULC S531 DETECTION TYPE Dual Ionization Chamber HUMIDITY RANGE 10% to 93% Relative Humidity KIT DIMENSIONS 13cm x 13cm x 3.8cm
YELLOW
BLACK
WHITE
RELAY
STROBE
WHITE
WHITE
N.C. (RED)
120 V INPUT
YELLOW
COMMON (GRAY)
BLACK
N.O. (BLUE)
BLACK
BLACK
WHITE
WHITE
An ISO 9002 Certified Company
Controls Americas 3505 Laird Road Unit #14 Mississauga, Ontario L5L 5Y7 Canada Customer Service Telephone +1 800 387 7978 Customer Service Facsimile +1 905 828 1265 iccacustomerservice@invensys.com
Technical Service Telephone +1 800 445 8299 Facsimile +1 630 260 7243 technicalservice@invensys.com
See technical specifications for agency listings on
www.invensyscontrols.com ©2006 Invensys Controls Americas - #150-1997
individual components.