CO Alarm Features (cont.)

This CO alarm is designed to detect carbon monoxide gas from any source of combustion. It is NOT designed to detect smoke, fire, or any other type of gas. If this CO alarm sounds its alarm horn, DO NOT assume that it is a false alarm. The alarm horn requires your immediate action.

This product is intended for use in ordinary indoor locations of family living units. It is not designed to measure compliance with Occupational Safety and Health Administration (OSHA) commercial or industrial standards. Where to Install Your CO Alarm

Carbon monoxide gas can be anywhere and everywhere. CO gas is equal to or slightly lighter than air, and disperses evenly with the air in a room. Therefore, install this CO alarm where air circulation is best. DO NOT mount the CO alarm within 1 foot of the ceiling/wall or wall/wall intersection, or other dead air spaces.

Since most CO fatalities occur while families are sleeping, we recommend that you install at least one CO alarm in the hallway outside each separate sleeping area and one inside each bedroom or sleeping area.

We also recommend that you install a CO alarm on every separate living level of the home where household members frequently spend time, as well as in the basement. See Figures 1, 2, and 3 for typical CO alarm loca- tions within the home.

This alarm can share the interconnect wire of smoke and heat alarms, BUT this alarm will remain silent if smoke is detected by the interconnected smoke and heat alarms. Therefore, it is necessary to install both a CO alarm and smoke alarm in those areas to be protected.

CAUTION !

This alarm will only indicate the presence of carbon monoxide gas at the sensor. Carbon monoxide gas may be present in other areas.

LIVED-IN ATTIC

BEDROOM BEDROOM

BATH

BEDROOM

BATH

BEDROOM

FAMILY / GREAT ROOM

BEDROOM BEDROOM BATH

KITCHEN

BATH

LIVING ROOM

KITCHEN

LIVING ROOM

FURNACE

ROOM

FURNACE

UTILITY

BASEMENT

BASEMENT

ROOM

ROOM BASEMENT

Key CO alarm locations

FIGURE 1

FIGURE 2

FIGURE 3

  • DO NOT install CO alarms:
  • Near bathrooms or in shower areas. Steam and aerosol sprays can disable the alarm.
  • In closets, crawlspaces, unused attics, or unheated areas where surrounding air temperatures may go below 40°F (4.4°C) or above 100°F (37.8°C).
  • Within five feet of any fuel-burning appliance (stove, kerosene heater, furnace, fireplace, etc.).
  • Within one foot of any wall, corner, or other dead air spaces.
  • In rooms where chemicals or cleaning supplies are frequently used (paint, hair spray, thinner, etc.). Allow plenty of ventilation in rooms where chemicals are used.
  • Directly above a sink, bathtub or basin.
  • Directly above or below air exchange or heating vents.
  • Behind drapes, furniture, or appliances that could block air flow to the CO alarm.

This unit cannot be used in recreational vehicle applications.

bustibles se queman sin que haya una cantidad suficiente de oxígeno (combustión incompleta). Este tipo de mal funcionamiento puede ocurrir en cualquier artefacto que queme combustible y en cualquier momento. Por ejemplo, muchas chimeneas se pueden llenar de hojas en el otoño, y si hay una suficiente cantidad de hojas, se acumulará suciedad y hollín en la chimenea y se interrumpirá la ventilación adecuada. Esto puede hacer que el CO entre a la casa y el resultado puede ser fatal. Sin embargo, con un mantenimiento y limpieza adecuados se puede reducir la posibilidad de acumulación de CO. El envenenamiento con monóxido de carbono es un asunto grave. Muchas familias lo sufren todos los días, y más de mil vidas se pierden cada año debido a este gas casero mortal. Si se mantiene y cuida adecuadamente, la alarma de CO le puede dar a los miembros de la familia una advertencia anticipada de las emisiones de CO. Sírvase leer bien este manual para aprender cómo instalar, operar, limpiar y reparar adecuadamente la alarma de CO, así como para enterarse de recomendaciones importantes sobre seguridad a fin de proteger a su familia del envenenamiento fatal con CO. Los símbolos siguientes identifican los mensajes importantes sobre seguridad que hay en este manual

CUIDADO Cuando vea este símbolo, usted debe saber que, si no se toma en cuenta el mensaje, la situación peligrosa PUEDE causar o CAUSARÁ lesiones corporales leves.

Show 6 more labels / short text on this page
split level · single story · two story · ! · ! · !
Page 4 of the Firex Carbon Monoxide Alarm (pmn) user manual — FIGURE 4
Page 4 · click to enlarge
Page 4

How to Install Your CO Alarm Once you have decided the best place to install the CO alarm(s), follow these steps:

ELECTRICAL SHOCK HAZARD. Turn off power at the main fuse box or circuit breaker by removing the fuse or switching the circuit breaker to the OFF position.

CAUTION !

Check local codes for specific mounting require- ments in your area.

1. From back of CO alarm, slide mounting plate and lift from base. See Figure 4.
2. Connect new 9-volt battery to battery connector inside compartment and slide door closed snapping it into place. New 9V battery comes from the factory installed backwards inside the battery compartment. Replace battery with Eveready 216, 522, 1222 or equivalent from your local retailer.

FIGURE 4

3. Align mounting plate with junction box mounting holes.
4. Gently pull household wires through center hole of mounting plate.
5. Secure mounting plate to junction box.
6. With a small wire connector, connect white wire from the CO alarm to white household wire.
7. Connect black wire from the CO alarm to the black household wire.
Firex Carbon Monoxide Alarm (pmn) — FIGURE 4 diagram (page 4)
Fig. 1
8. For interconnecting alarms: • Use #18 AWG minimum solid or stranded wire. When interconnecting, maximum wire length between any two is 1,500 feet for #18 AWG or 4,000 feet for #14 AWG (20 OHMS loop resistance.) See Figure 5.
  • This CO alarm may be interconnected with as many as 11 other Firex CO alarms or with as many as 12 Firex smoke alarms, and 5 CO or heat alarms for a total number of 18 units.
  • This CO alarm may be interconnected with Firex models FADC, ADC, PAD and ADH smoke and heat alarms. DO NOT connect to any other model CO, smoke or heat alarm.
  • Note that this CO alarm will not cause interconnected smoke and heat alarms to sound their horn. This CO alarm will remain silent if interconnected smoke and heat alarms are sounding even if there is a buildup of CO.
  • Connect CO and smoke alarms to a single AC branch circuit. If local codes do not permit connection to a single AC branch circuit, be sure the neutral wire is common to all circuits used. 9. Align tabs on back of base with slots on side of mounting plate. Slide base down to lock into position. See Figure 6. 10. Turn power on at the main fuse box or circuit breaker. The CO alarm will flash the red LED and emit a short beep during its power-up cycle. The green POWER light will stay on as long as the CO alarm is receiving AC power.
Firex Carbon Monoxide Alarm (pmn) — FIGURE 4 diagram (page 4)
Fig. 2

ADVERTENCIA CONOZCA LAS FUENTES COMUNES DE MONÓXIDO DE CARBONO. Las fuentes comunes de monóxido de carbono son calderas para calefacción, aparatos para calentar, calentadores de agua, cocinas o estufas a gas, calentadores a queroseno, chimeneas, parrillas que se usan dentro de la casa, motores o máquinas que estén funcionado en garajes unidos a la casa y dispositivos a gasolina como los generadores y las bombas que se usan en emergencias. Conozca cómo usar adecuadamente cada aparato o dispositivo y haga que les den servicio y se limpien regularmente. Use el sentido común y siga cuidadosa- mente las instrucciones sobre seguridad y riesgos siempre que los use.

  • ADVERTENCIA Las personas con problemas médicos pueden considerar usar dispositivos de advertencia que tengan señales audibles o visuales para concentraciones de monóxido de carbono por debajo de 30 ppm. Características de la alarma de CO
  • Pila de repuesto de 9 V
  • Arnés para conexión rápida de los alambres para facilitar y abreviar la instalación
  • Interconexión inteligente: cable compartido de interconexión con el cual las alarmas de humo distinguen entre las señales de alarma de hum y de monóxido de carbono en el cable de interconexión
  • Su forma cuadrada la diferencia claramente de las alarmas de humo
  • Botón grande para probar y recalibrar: fácil de usar
  • Sistema de alarma de luz y sonido de tres niveles; usted siempre sabe si: 1. La unidad está recibiendo la corriente alterna. 2. La alarma requiere cambiarse de inmediato. 3. Hay niveles peligrosos de CO.
  • Especificaciones eléctricas: 120 V de CA, 60 Hz, 0,05 amp.

! · !

Page 5 of the Firex Carbon Monoxide Alarm (pmn) user manual — Características de la alarma de CO (continuación)
Page 5 · click to enlarge
Page 5

How to Install Your CO Alarm (cont.)

11. Firmly PRESS AND RELEASE THE TEST/RESET button. See Figure 7. The alarm should sound a short tone. The amber SERVICE light will turn on, and the CO alarm will go through its test cycle. The red LED will flash, and the alarm will beep four times followed by 5 seconds of silence and then repeat the cycle. After the test cycle, the amber SERVICE light will turn off, and the green POWER light will remain lighted which means the CO alarm is operating properly.

PRESS IN, HOLD, AND RELEASE TO RESET AND/OR TEST.

FIGURE 7

12. If the alarm is interconnected to other CO alarms, press and hold the TEST/RESET button until the red light turns on. Other interconnected alarms also will beep four times followed by 5 seconds of silence. The red ALARM light on other alarms will not light during this test. If the alarm is interconnected with smoke or heat alarms, the smoke and heat alarms will remain silent.

13. Two self-adhesive labels have been provided with instructions indicating what to do if the alarm sounds. Add the phone numbers of your emer- gency services provider and a qualified technician to each label. Place one of the labels in a visible area next to the alarm, and place the other label near a source of fresh air which will be used as a gathering place if the alarm sounds. How to Operate Your CO Alarm This carbon monoxide alarm has been evaluated by UL and meets the applicable UL standards and requirements.

This CO alarm has a three light and sound alarm system:

CARBON MONOXIDE ALARM

ON

SERVICE

ALARMM OVE T O F RESH A IR

On Green indicator constantly ON indicates unit is receiving AC power.

Service Amber indicator flashing and alarm horn beeping every thirty seconds indicates unit fault. Press and release the TEST/RESET button. If the alarm returns to displaying the fault signal, the CO alarm is not operating properly. REPLACE THE CO ALARM IMMEDIATELY. SEE THE WAR- RANTY INFORMATION AT THE END OF THIS MANUAL.

Alarm Red indicator flashes and alarm horn sounds four fast beeps and then is quiet for 5 seconds. When the CO concentration builds to a level that is equal to 70 ppm or greater for the duration identified within the standard, the following will occur:

  • The ALARM light and sound signals will activate. See the WHAT TO DO IF YOUR ALARM SOUNDS section of this manual for important action steps to be taken.
  • If you wish to press the TEST/RESET button during this time, the alarm will become quiet for up to six minutes. The ALARM signals will be reenergized within 6 minutes from the time the reset button is pressed if the concentration of carbon monoxide surrounding the alarm remains at 70 ppm or greater.
  • The alarm will remain silent if the CO concentration has decreased below the alarm level of the standard. See WHAT TO DO IF YOUR ALARM SOUNDS section of this manual for important action steps to be taken.
  • The alarm will continue for as long as the condition exists.

The alarm will not permanently end its alarm mode until the concentration of CO has been reduced to a safe level.

Características de la alarma de CO (continuación)

ADVERTENCIA El gas monóxido de carbono puede estar en cualquier parte y en todas partes, pesa lo mismo o es ligeramente más liviano que el aire y se dis- persa uniformemente con el aire de la habitación. Por consiguiente, instale esta alarma de CO donde el aire circule mejor. NO instale la alarma de CO a un pie 30 cm (1 pie) o menos de la intersección de la pared con el cielo raso, en la intersección de dos paredes, ni en otros espacios de “aire muerto”. Ya que la mayoría de las muertes por CO ocurren mientras las familias están durmiendo, recomendamos que instale, por lo menos, una alarma en los pasadizos de las diferentes áreas de dormir y otra alarma en cada uno de los dormitorios o áreas de dormir. También recomendamos que instale una alarma en cada una de las áreas o habitaciones de los diferentes niveles donde los miembros de la familia están con frecuencia, así como en el sótano. Las figuras 1, 2 y 3 mues- tran las ubicaciones típicas de las alarmas dentro de la casa. Esta alarma puede compartir el cable de interconexión de las alarmas de humo y calor, PERO esta alarma permanecerá en silencio si el humo es detectado por las alarmas interconectadas de humo y calor. Por lo tanto,

Show 6 more labels / short text on this page
(Power on/ operating) · (Problem with Alarm) · (Dangerous CO levels) · ! · ! · !
Page 6 of the Firex Carbon Monoxide Alarm (pmn) user manual — FIGURA 2 FIGURA 3
Page 6 · click to enlarge
Page 6

How to Operate Your CO Alarm (cont.) Test Your CO Alarm Weekly Momentarily press the TEST/RESET button and note the alarm sound. Also note that the LED indicators flash the proper test sequence as described in HOW TO INSTALL YOUR CO ALARM. If the alarm does not beep after depressing the TEST/RESET button or exhibit the correct LED test sequence, immediately return the CO alarm to Maple Chase for repair or replacement. See the warranty information at the end of this manual. Do not attempt to repair the unit yourself as this may cause damage and will void the warranty. What to Do if Your Alarm Sounds

Carbon Monoxide cannot be seen, felt, tasted, or smelled – but it can be FATAL.

IF THE RED ALARM LED INDICATOR IS FLASHING AND THE ALARM IS SOUNDING APPROXIMATELY EVERY FIVE SECONDS, IT INDICATES THE PRESENCE OF CO WHICH CAN BE FATAL. YOU MUST QUICKLY DO THE FOLLOWING:

1. Operate TEST/RESET button;
2. Call your emergency services [fire department or 911];
3. Immediately move to fresh air — outdoors or by an open door/window. Make certain that all persons are accounted for. Do not reenter the premises nor move away from the open door/window until the emergency services responders have arrived, the premises have been aired out, and your alarm remains in its normal condition.

4. After following steps 1 — 3, if your alarm reactivates within a 24 hour period, repeat steps 1 — 3 and call a qualified appliance technician ( ) to investigate sources of CO from fuel burning equipment and appliances, and to inspect for proper operation of this equipment. If problems are identified during this inspection, have the equipment serviced immediately. Note any combustion equipment not inspected by the technicians and consult the manufacturers’ instruc- tions, or contact the manufacturers directly, for more information about CO safety and this equipment. Make sure that motor vehicles are not, and have not been, operating in an attached garage or adjacent to the residence.

If the CO alarm sounds its alarm horn again, it has sensed CO. This is not a false alarm. Maintenance and Cleaning This CO alarm does not require any maintenance except occasional dust- ing or cleaning. If necessary, occasionally vacuum the case of the CO alarm. To clean the CO alarm, unplug each CO alarm from its wiring har- ness and use a damp cloth to clean the OUTSIDE of CO alarm case. DO NOT remove cover or attempt to clean inside the CO alarm. Dry the cover completely and plug each CO alarm back onto the wire harness and replace on the mounting bracket. Press in, hold, and release TEST/RESET button on each CO alarm to test after cleaning.

Do not use abrasive cleansers, or spray the CO alarm with cleaning agents or waxes, especially cleaners containing ammonia. These liquids may impair the performance of sensors. Do not submerge the CO alarm in water.

Troubleshooting

ProblemThe alarm is properly connected to AC power, but the green

LEDs do not light. Solution: Return alarm to Maple Chase Company for service (see warranty). Problem: Amber FAULT light flashes every 30 seconds.

es necesariio instalar tanto la alarma de monóxido de carbono como la alarma de humo en aquellas áreas que van a ser protegidas.

CUIDADO Esta alarma solamente indicará la presencia de monóxido de carbono donde está el sensor. Es posible que haya el gas monóxido de carbono en otras áreas.

ÁTICO QUE SE USA

DORMITORIO

BAÑO

DORMITORIO

DORMITORIO

BATH

DORMITORIO

SALA DE ESTAR O DE JUEGOS

DORMITORIO DORMITORIO

BAÑO

COCINA

BAÑO

SALA

COCINA

SALA

CUARTO DE LA CALDERA PARA

CUARTO DE LA CALDERA PARA CALE-

TALLER

Habitaciones en diferentes niveles

SÓTANO

CALEFACCIÓN

SÓTANO

FACCIÓN

SÓTANO

Clave Ubicación de las alarmas de CO

FIGURA 2 FIGURA 3

  • En clósets, espacios en que no se puede estar de pie, áticos que no se usan o en áreas sin calefacción, donde la temperatura del aire alrededor puede bajar de 4.4 (C (40 (F) o subir por encima de 37,8 (C (100 (F).
  • A menos de cinco pies 1,50 m (5 pies) de cualquier aparato o artefacto que queme combustible (cocinas o estufas, calentadores a queroseno, calderas para calefacción, chimeneas, etc.).
  • A 30 cm (1 pie) o menos de cualquier pared, esquina o espacios de “aire muerto”.
  • En habitaciones donde se usen con frecuencia químicos o productos de limpieza (pinturas, rociadores del cabello, diluyentes, etc.). Cuando se usen químicos, fíjese que las habitaciones estén bien ventiladas.
Show 4 more labels / short text on this page
! · Un piso · Dos pisos · !
Page 7 of the Firex Carbon Monoxide Alarm (pmn) user manual — ADVERTENCIA
Page 7 · click to enlarge
Page 7
Troubleshooting (cont.) SolutionPress the TEST/RESET button to allow the alarm to recheck

itself internally. If the amber LED continues to flash, the alarm must be returned to Maple Chase Company for service (see warranty). Symptoms of Carbon Monoxide Poisoning Carbon monoxide poisoning has many symptoms. Some symptoms are very similar to the flu, the effects of intoxication, or drug usage. In many CO cases, people feel ill and stay home to rest. This only compounds the CO poisoning because they stay in the home where CO is present.

As CO levels rise, the symptoms become more extreme. At low levels people will suffer headaches and mild nausea. At higher levels unconscious- ness, heart failure, and even death can occur.

The following symptoms are related to CARBON MONOXIDE POISONING and should be discussed with ALL members of the household:

Mild Exposure: Slight headache, nausea, vomiting, fatigue (often described as flu-like symptoms).

Medium Exposure: Severe throbbing headache, drowsiness, confusion, fast heart rate.

Extreme Exposure: Unconsciousness, convulsions, cardio-respiratory failure, death. Many cases of reported carbon monoxide poisoning indicate that while victims are aware they are not well, they become so disoriented they are unable to save themselves by either exiting the building or calling for assistance. Also, young children, the elderly, and household pets may be the first affected by CO poisoning.

The important factor with any CO poisoning, however, is time. At high levels, CO can cause death in just minutes. At lower levels, it could take from hours to days of constant CO exposure to have the same life-threatening effect.

The chart below illustrates the symptoms of CO poisoning by concentration of CO and its effect over time.

Slight headache within 2-3 hours.

Frontal headache within 1-2 hours.

Dizziness, nausea, and convulsions within 45 minutes. Insensible within 2 hours.

Headache,dizziness and nausea within 20 minutes. Death within 2 hours.

Headache,dizziness and nausea within 5-10 minutes. Death within 30 minutes.

Headache,dizziness 1-2 minutes. Death in less than 15 minutes.

D e a t h i n l e s s t h a n 3 m i n u t e s .

|

0 100 200 300 400 500 600 700 800 900 1000 1100 1200

Concentration of CO in air (ppm)

Conditions That Can Cause CO Levels to Change The following conditions can result in transient CO situations in the home. 1. Excessive spillage or reverse venting of fuel burning appliances caused by outdoor ambient conditions, such as: a. Wind direction and/or velocity, including high gusts of wind. Heavy

air in the vent pipes (cold/humid air with extended periods between cycles). b. Negative pressure differential resulting from the use of exhaust fans. c. Simultaneous operation of several fuel burning appliances compet-

ing for limited internal air. d. Vent pipe connections vibrating loose from clothes dryers, furnaces,

or water heaters. e. Obstruction in the vent pipe or unconventional vent pipe designs

which can amplify the above situations.

2. Extended operation of unvented fuel burning devices (range, oven, fireplace, etc.). 3. Temperature inversions which can trap exhaust gasses near the ground. 4. Car idling in an open or closed attached garage, or near a home.
  • Directamente sobre un lavadero, tina o lavamanos.
  • Directamente por encima o por debajo de conductos de intercambio de aire o calefacción.
  • Detrás de cortinas, muebles o artefactos que puedan obstruir el flujo de aire hacia la alarma de CO.

ADVERTENCIA

CUIDADO Consulte los códigos locales sobre los requisitos específicos de instalación de su área. 1. Deslice la placa de montaje que está en la parte posterior de la alarma de CO y levántela de la base. Vea la Figura 1. 2. Conecte la nueva pila de 9 V a su conector que está dentro del compartimiento y cierre la puerta deslizándola hasta que encaje en su sitio. La nueva pila de 9 V viene de fábrica al revés dentro del compartimiento de la pila. Para reemplazarla, use una pila Eveready 216, 522, 1222 o una equivalente que la puede comprar en un minorista local. 3. Alinee la placa de montaje con los orificios respectivos de la caja de empalmes. 4. Haga pasar con suavidad los alambres de la casa a través del orificio central de la placa de montaje. 5. Asegure la placa de montaje a la caja de empalmes.

! · ! · !

Page 8 of the Firex Carbon Monoxide Alarm (pmn) user manual — BLANCO
Page 8 · click to enlarge
Page 8

Home Safety Tips Many CO poisonings are caused by equipment failures due to poor main- tenance, product defects, and damaged parts. The following is a list of safety tips to help prevent CO poisoning within your home: 1. Have all fuel-burning appliances inspected and cleaned yearly by a qualified service technician. The furnace, water heater, and stove are some of the leading sources of CO in homes. 2. Clean fireplace vents and chimney regularly. A blocked chimney could cause a backdraft of CO into the home. Do not cap chimney. This will cause a backdraft of CO into the home. 3. Do not cap or cover a draft hood or exhaust vent to any appliance. This will trap dangerous CO inside the house. 4. Do not close off or confine your fuel-burning appliances in a closed area. They need plenty of ventilation to operate properly. 5. Do not use liquid propane (LP) or charcoal grills indoors. 6. Do not operate any gasoline-powered equipment indoors. 7. Allow for plenty of ventilation when using a kerosene heater. Do not use in small areas. Preventive maintenance, common sense, and a CO detection device are some of the best methods of preventing CO poisoning. However, a danger- ous situation can happen to anyone at any time. The following list illustrates some danger signs of CO presence. 1. Soot and dirt build-up seeping out of chimney or other exhaust vents. 2. A mostly yellow (rather than clear blue) burner flame or pilot flame in gas appliances. 3. A draft of air coming from an appliance, chimney, or vents. If you have flu-like symptoms or suspect CO poisoning, seek medical assistance immediately!

WARRANTY INFORMATION 5-YEAR CARBON MONOXIDE ALARM WARRANTY

Maple Chase Company warrants to the original consumer purchaser each new carbon monoxide alarm to be free from defects in material and workmanship under normal use and service for a period of five (5) years from date of purchase. Maple Chase Company agrees to repair or replace, at its option, any defective carbon monoxide alarm, provided that it is returned with postage prepaid and with proof of purchase date to Maple Chase. This warranty does not cover damage resulting from accident, misuse, or abuse or lack of reasonable care of the product. This warranty is in lieu of all other express warranties, obligations, or liabilities. THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED TO A PERIOD OF FIVE (5) YEARS FOR THE CARBON MONOXIDE ALARM FROM PURCHASE DATE. Some states do not allow limitations on how long an implied warranty lasts, so the above limitations may not apply to you. IN NO CASE SHALL MAPLE CHASE BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES FOR BREACH OF THIS OR ANY OTHER WARRANTY, EXPRESS OR IMPLIED, WHATSOEVER, EVEN IF THE LOSS OR DAMAGE IS CAUSED BY ITS NEGLIGENCE OR FAULT. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other legal rights which vary from state to state.

This product meets all the requirements of U.L. Standard 2034.

WHERE TO SEND YOUR CARBON MONOXIDE ALARM FOR SERVICE To return carbon monoxide alarms under warranty, send the CO alarm plus postage prepaid, a note describing the nature of the difficulty, and proof of date of purchase to:

In U.S.: In Canada:

Maple Chase Company Maple Chase Co. of Canada Product Service Department Service de réparation 28C Leigh Fisher Blvd. 3505 Laird Road – Unit #14 El Paso, TX 79906 Mississauga Ontario L5L 5Y7 United States of America Canada

Technical Service(800) 779-1719

M-F 7:30 - 5:30 CST

  • 6. Use un conector pequeño de alambres para conectar el alambre blanco de la alarma de CO con el alambre blanco de la corriente de la casa. 7. Conecte el alambre negro de la alarma de CO con el alambre negro de la corriente de la casa. 8. Para interconectar las alarmas:
  • Use un alambre trenzado o sólido que tenga un grosor mínimo No. 18 AWG. Cuando haga la interconexión, la distancia máxima entre dos alarmas es 457,20 m (1500 pies) si usa alambres No. 18 AWG o 1219,20 m (4000 pies) si usa alambre No. 14 AWG (resistencia de 20 ohmios en el tramo de conexión). Vea la Figura 2.
  • Esta alarma de monóxido de carbono puede ser interconectada hasta con 11 alarmas más de monóxido de carbono Firex, o hasta con 12 alarmas de humo Firex, y con 5 alarmas de monóxido de carbono o calor, para un total de 8 unidades.
  • Esta alarma de monóxido de carbono puede ser interconectada con los modelos de alarmas de humo y calor de Firex FADC, ADC, PAD y ADH. NO la conecte a ningún otro modelo de alarma de monóxido de carbono, humo o calor.
  • Tome nota de que esta alarma de monóxido de carbono no hará que las alarmas de humo y calor interconectadas suenen sus bocinas. Esta alarma de monóxido de carbono permanecerá en silencio si las alarmas de humo y calor interconectadas están sonando, aún si hay una acumulación de monóxido de carbono.
  • Conecte las alarmas de monóxido de carbono y de humo en un solo circuito derivado de CA. Si los códigos locales no permiten la conexión en un solo circuito derivado de CA, asegúrese de que el cable neutro sea común para todos los circuitos utilizados.

BLANCO

AMARILLO BLANCO

BLANCO

AMARILLO

A NEUTRO

NEGRO

NEGRO

NEGRO

A 120 V DE CA (CON CORRIENTE)

Ask about the Firex Carbon Monoxide Alarm (pmn)

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Firex Carbon Monoxide Alarm (pmn)

Be the first to ask — other owners or our team will answer.

Original document

Firex Carbon Monoxide Alarm (pmn) manual PDF

16 pages·850 KB·Carbon Monoxide Alarm·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…