UV-AIRE™ AIR PURIFYING SYSTEM

ModelUV-E (For use with 12”, 18” and 28” Field Controls Lamps)

(120/240 volt application)

Field Controls UV-E — (120/240 volt application) diagram (page 1)
Fig. 1 · (120/240 volt application)

ITEMS INCLUDED IN KIT:

1-UV-E power unit (NEMA3 housing) 1-Mounting Template 4-Sheet metal mounting screws 1-Angled mounting bracket 1-Flat mounting bracket 1-Instruction Sheet 1-Wing nut 2-Hex nuts 1-Lamp

UV-C light inhibits the growth and reproduction of germs and bacteria that circulate through a homes’ heating and air conditioning system. The treatment is a safe, silent, and proven way to make your home a healthier place to live.

READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION

LEAVE THE INSTALLATION INSTRUCTIONS WITH THE OWNER/OPERATOR OF THE DEVICE

AFTER OPENING THE CARTON, UNPACK AND INSPECT THE UNIT AND LAMP FOR DAMAGE.

DO NOT INSTALL THIS UNIT IF ANY DAMAGE IS NOTICEABLE.

SAFETY CONSIDERATIONS

  • Looking directly at the UVC light may cause permanent eye damage or blindness.
  • Never operate the UV-Aire™ Air Purifying System out of the plenum . WARNING: UV light will break down plastic materials not rated for UV exposure: (Examples: wire insulation, flex duct, drain pans and humidifiers)
  • The unit must be mounted at least 30” from the above stated type of materials.
  • If it is necessary to mount the unit in direct line of site of these types of materials, they must be shielded with aluminum foil, aluminum foil tape, or sheet metal.
Field Controls UV-E — SAFETY CONSIDERATIONS diagram (page 1)
Fig. 2
Page 2 of the Field Controls UV-E user manual — II. INSTALLATION
Page 2 · click to enlarge
Page 2

I. GENERAL INFORMATION

This product is not sold as a medical device and is not for the purpose of diagnosis of any disease or condition nor for use in the mitigation, treatment, or prevention of any disease or condition.

There are different size units available, depending on the square footage of your home. See chart below for determining your homes needs.

Field Controls UV-E — I. GENERAL INFORMATION diagram (page 2)
Fig. 3
Lamp LengtMinimum h Duct WidthVoltsAmpsHzWattsMax Air Temp °FLamp Intensity at meter 12”9120/240 0.56030150°37 μW/cm2 18”14120/240 0.56030150°73 μW/cm2 28”22120/240 1.16060150°105 μW/cm2

II. INSTALLATION

Field Controls UV-E — II. INSTALLATION diagram (page 2)
Fig. 4
1. Determine a suitable location on either the supply or return for the unit as shown in Figure 1. The unit must be mounted at least 3 feet from any flex duct type material.
2. Apply mounting template to air duct as shown in Figure 2.
3. Drill 1/8” diameter mounting holes at positions indicated on template. (See Figure 2)
4. Using a 2” hole saw, drill out lamp hole as shown on template. (See Figure 2)
5. Drill a 7/8” inspection hole as shown on template. (See Figure 2)
6. Remove template.
7. Mount unit to duct using the 4 supplied sheet metal screws. (See Figure 3)
Field Controls UV-E — II. INSTALLATION diagram (page 2)
Fig. 5
Page 3 of the Field Controls UV-E user manual — I. GENERAL INFORMATION
Page 3 · click to enlarge
Page 3
9. Connect to an appropriate power source such as an AC power disconnect box or to a circuit breaker panel. (See Figure 8)
10. Determine length of wire and conduit necessary according to power connection and install wiring conduit and water tight connector as shown in example figure 4. (Supplied by installer.)
11. Remove wiring access cover to expose terminal block. (Figure 5)
Field Controls UV-E — I. GENERAL INFORMATION diagram (page 3)
Fig. 6
Field Controls UV-E — I. GENERAL INFORMATION diagram (page 3)
Fig. 7
12. Push power source wires through bushing in access cover then begin securing wires according to the wiring diagram in figure 8. (See Figures 6 & 7)
Field Controls UV-E — I. GENERAL INFORMATION diagram (page 3)
Fig. 8
Field Controls UV-E — I. GENERAL INFORMATION diagram (page 3)
Fig. 9
13. Replace access cover.
14. Group wires together and tuck in wire clip on right side of box. (See Figure 9)
Field Controls UV-E — I. GENERAL INFORMATION diagram (page 3)
Fig. 10
Page 4 of the Field Controls UV-E user manual — L AMP I NSTALLATION
Page 4 · click to enlarge
Page 4
15. Determine whether to use flat or angled bracket. (Refer to UV-Aire Configurations in Section III for aid in this decision)
Field Controls UV-E — L AMP I NSTALLATION diagram (page 4)
Fig. 11

a. Flat Bracket Installation

i. Remove the two hex nuts and flat bracket from included bagged hardware. ii. Install the flat bracket and secure to the unit base with the hex nuts provided. (See Figure 10)

b. Angled Bracket Installation

Field Controls UV-E — L AMP I NSTALLATION diagram (page 4)
Fig. 12

i. Remove the two hex nuts and angled bracket from included bagged hardware. ii. Install the angled bracket and secure to the unit base with the hex nuts provided. (See Figure 11) The angle bracket may be mounted in 4 positions allowing the bulb to either be angled up and down or left to right, depending upon duct design. (Figures A-D) NOTE: Be sure to note location of lamp hole in bracket relative to unit

base.

Field Controls UV-E — L AMP I NSTALLATION diagram (page 4)
Fig. 13
Field Controls UV-E — L AMP I NSTALLATION diagram (page 4)
Fig. 14
Field Controls UV-E — L AMP I NSTALLATION diagram (page 4)
Fig. 15
Field Controls UV-E — L AMP I NSTALLATION diagram (page 4)
Fig. 16

L AMP I NSTALLATION

This unit is listed for use with Field Controls’ lamps ONLY. You will need to determine proper lamp selection based on duct size and desired configuration. (Refer to configuration table on page 6 of this manual)

Field Controls UV-E — L AMP I NSTALLATION diagram (page 4)
Fig. 17
16. Remove tag and alcohol from lamp. Wipe off lamp being sure not to touch lamp with bare hands. The oils in your hands may cause the lamp to prematurely expire.
17. Insert lamp through hole in bracket until lamp is snug against the bracket. (See Figure 12)
Show 4 more labels / short text on this page
Figure A · Figure B · Figure C · Figure D
Page 5 of the Field Controls UV-E user manual — L AMP I NSTALLATION
Page 5 · click to enlarge
Page 5
Field Controls UV-E — L AMP I NSTALLATION diagram (page 5)
Fig. 18
18. Swing securing bracket over end of lamp and hand-tighten the provided wing nut on stud. (See Figure 13)
Field Controls UV-E — L AMP I NSTALLATION diagram (page 5)
Fig. 19
19. Plug ballast plug into end of lamp and reconnect power supply. (See Figure 14)
20. Flip the red power switch to the on position. (Light on switch should be on indicating power.)
21. Look through view port to be sure lamp is working. You should see a blue glow. (The view port is covered with a plastic lens that blocks the UVC rays.)
22. If the lamp is not glowing, make sure the wiring is correct and that the ballast is plugged in securely to lamp. If lamp still does not glow, contact technical support at 1-252-522-3031 for further assistance.
23. After unit has been found to be working properly, note date of installation on inside cover, close cover and engage latch. Apply supplied wire tie to latch or other locking mechanism to provide safety.
Page 6 of the Field Controls UV-E user manual — Good Better
Page 6 · click to enlarge
Page 6

III. BULB MOUNTING BRACKET SELECTION AND INSTALLATION

The UV-AIRETM units come with an angled mounting bracket and flat mounting bracket to position the bulb either straight or at an angle. Choose one or the other bracket method best suited for your needs. Refer to the configurations chart below when making your selection.

UV-Aire™ Configurations

Good Better

Field Controls UV-E — Good Better diagram (page 6)
Fig. 20 · Good Better
Field Controls UV-E — Good Better diagram (page 6)
Fig. 21 · Good Better
Field Controls UV-E — Good Better diagram (page 6)
Fig. 22 · Good Better
Field Controls UV-E — Good Better diagram (page 6)
Fig. 23 · Good Better

(Flat Bracket) (Fits a minimum 12” Duct)

(Flat Bracket) (Fits a minimum 18” Duct)

Installation (Angled Bracket) (Fits a minimum 8” Duct)

Installation (Angled Bracket) (Fits a minimum 14” Duct)

ANGLED LAMP MOUNTING BRACKET SPECIFICATIONS

Use the specifications below to determine allowable clearances for proper mounting of the UV-Aire™ unit on the duct.

Diagram A LAMP OFFSET DIMENSIONS Lamp LengthABLamp Part No. 12”8-1/26-1/246365401 18”13-1/210-5/1646365402 28”21-3/816-1/446365403
Show 4 more labels / short text on this page
Standard 90° Installation · Standard 90° Installation · Patent Pending 45° · Patent Pending 45°
Page 7 of the Field Controls UV-E user manual — VII. REPLACEMENT PARTS LIST
Page 7 · click to enlarge
Page 7

IV. MAINTENANCE

1. Inspect and clean lamp at least every 6 months.
2. Replace your UV-Aire™ Air Purifying System lamp once a year to maintain the lamps maximum output intensity. The lamp should operate continuously for maximum lamp life and light effectiveness.

V. REPLACEMENT PROCEDURE

VERY IMPORTANT: Turn switch on unit to ‘OFF’ position and disconnect from power source.

1. Remove wire tie or locking mechanism from latch on unit.
2. Unplug ballast plug from end of lamp.
3. Remove the wing nut on securing bracket. Swing out securing bracket to clear lamp.
4. Slide lamp out carefully.
5. Replace lamp following the appropriate procedure based on bracket selection in the installation section.
6. UV lamps contain a small amount of mercury, like a typical fluorescent lamp. Check with your local waste management authority for local disposal or recycling requirements. According to the EPA’s Universal Waste Rule, these types of lamps may be disposed of into household waste
7. After replacing lamp, make sure a new Lamp Replacement Label (supplied with lamp replacement) is applied to the housing and dated with the date of installation.
8. Replace wire tie or locking mechanism to latch.

VI. TROUBLESHOOTING GUIDE

1. If unit does not light up replace bulb.
2. If unit still does not light up after replacing bulb, replace ballast.

VII. REPLACEMENT PARTS LIST

Lamp LengthLAMPBALLAST (Field Controls Part Number)(Field Controls Part Number) 12”4636540146365506 18”4636540246365506 28”4636540346365506

For replacement parts, contact your local heating service company. Any questions, please contact Field Controls at:

Phone252-522-3031 Fax: 252-522-0214 Email: sales@ fieldcontrols.com
Page 8 of the Field Controls UV-E user manual — VIII. FLEX DUCT INSTALLATION
Page 8 · click to enlarge
Page 8

VIII. FLEX DUCT INSTALLATION

For installations on duct systems with a metallic main duct and flex duct branches, follow the instructions in figure 15 below.

Limited Warranty Field Controls, L.L.C. warrants that the following Field Controls, L.L.C. products sold hereunder, shall be free from defects in material and workmanship under normal use for eighteen (18) months from date of manufacturing by the consumer excepting the provisions numbered below. UV-LAMPS/BULBS Field Controls, L.L.C. warrants that the following Field Controls, L.L.C. products sold hereunder, shall be free from defects in material and workmanship under normal use for ninety (90) days from date of installation by the consumer excepting the provisions numbered below. Provisions:

1. Field Controls shall have no obligation in the event the customer is unable to provide receipt showing the date the customer purchased the product(s) or accurate date code information. 2. The product must be properly installed, maintained and operated under normal conditions. 3. Field Controls shall not be liable for any consequential and incidental damages, resulting from failure of a Field Controls, L.L.C. product, failure to deliver, delay in delivery, delivery in nonconforming condition, or for any breech of contract or duty between Field Controls, L.L.C. and the customer. 4. Field Controls, L.L.C. products are often intended for use in specific applications. Field Controls, L.L.C. makes no warranty if a Field Controls, L.L.C. product is used in applications other than intended. 5. Field Controls, L.L.C. makes no warranty of any kind in regard to any other manufacturer’s products distributed by Field Controls, L.L.C. Field Controls, L.L.C. will pass on all warranties made by the manufacturer and where possible, will expedite the claim on behalf of the customer, but ultimately, responsibility for disposition of the warranty claim lies with the manufacturer.

The health aspects associated with the use of these products and their ability to aid in disinfecting of environmental air have not been investigated by UL.

Field Controls UV-E — VIII. FLEX DUCT INSTALLATION diagram (page 8)
Fig. 24

P/N 46427300 Rev E 05/04

Ask about the Field Controls UV-E

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Field Controls UV-E

Be the first to ask — other owners or our team will answer.

Original document

Field Controls UV-E manual PDF

8 pages·563 KB·Air Cleaner·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…