EN
Field Controls logo
Official user manual

Field Controls 24v

12 pages·1.3 MB·Air Cleaner·PDF·ENDEFRITNLJA
Field Controls 24v
Table of Contents 19 sections Air Purification · June 2007 · Filters Trap UV-Aire Zaps! ™ · Fungus Mold · … ShowHide
Page 1 of the Field Controls 24v user manual — June 2007
Page 1 · click to enlarge
Page 1
Field Controls 24v — Air Purification diagram (page 1)
Fig. 1 · Air Purification

Air Purification

New Package! 24 volt transformer included!

A I R P U R I F I C A T I O N G U I D E

w w w . f i e l d c o n t r o l s . c o m

June 2007

Page 2 of the Field Controls 24v user manual — Filters Trap UV-Aire Zaps! ™
Page 2 · click to enlarge
Page 2
Field Controls 24v — Filters Trap UV-Aire Zaps! ™ diagram (page 2)
Fig. 2 · Filters Trap UV-Aire Zaps! ™

The Whole House Solution Field Controls offers a complete line of UV-Aire products for any home or business, with a variety of duct-mounted UV-Aire models designed for forced-air heating and cooling systems. UV-Aire germicidal lamps continuously attack airborne mold, bacteria and viruses as they circulate through your ductwork.

The UV-500C and UV-1500C provide concentrated UV germicidal protection in bedrooms, living rooms, and offices… where it’s needed most. Each portable model utilizes a motorized fan with multi-speed control to quietly and efficiently circulate and treat indoor air. The UV-500C is recommended for rooms up to 500 square feet, while the UV-1500C can purify areas up to 1500 square feet.

For homes and businesses without a forced-air system, Field Controls manufactures two portable models. The portable models combine the purifying power of UV with high efficiency filtration and carbon filtration to reduce dust, pollen, odors, and Volatile Organic Compounds (VOCs).

For those who require extra protection, the 24/7 benefits of the in-duct models can be enhanced with the concentrated power of the portable units. The combined use of portable and in-duct models is an extremely effective whole house solution. This approach is recommended for anyone with allergies, respiratory illnesses such as asthma, or a compromised immune system*.

Field Controls 24v — Filters Trap UV-Aire Zaps! ™ diagram (page 2)
Fig. 3 · Filters Trap UV-Aire Zaps! ™

Filters Trap UV-Aire Zaps! ™

Field Controls 24v — Filters Trap UV-Aire Zaps! ™ diagram (page 2)
Fig. 4 · Filters Trap UV-Aire Zaps! ™

With 40-75 air changes per day during normal operation, the cumulative effect of UV-Aire in-duct models reduces airborne bacterial concentrations. UV-Aire works in combination with a quality filter. An upgraded media filter

(MERV 8 or higher) is recommended. Filters trap larger particles, allowing microscopic organisms to pass through where they are zapped in the UV-Aire treatment zone.

*UV-Aire is not a medical device and makes no medical claims.

UV-Aire® In-duct · UV-500C Portable · UV-1500C Portable

Page 3 of the Field Controls 24v user manual — Fungus Mold
Page 3 · click to enlarge
Page 3

®

Indoor Air: High Concentrations of Biological Contaminants With tighter building construction in recent years, the quality of indoor air has declined dramatically.

Field Controls 24v — ® diagram (page 3)
Fig. 5

The air circulating in the ductwork of the average home or office can be concentrated with contaminants including molds, bacteria, viruses, and dust mites. We fill our lungs up to 20,000 times each day. Over time, these contaminants can cause inflammation of the mucous membranes, upper respiratory problems, asthmatic conditions, headaches, and flu-like symptoms.

Filtering systems offer little or no help because these airborne contaminants either pass through the filter or simply collect on the filter medium, creating a breeding ground. Now, with the UV-Aire® Air Purifying System, a solution is available to directly address the problems associated with poor indoor air quality.

The Sun: Nature’s Outdoor Air Purifier For years, scientists have known that one of the most effective air purifiers is natural sunlight. Not the light we see when we look out the window, but the invisible “C” band, ultraviolet rays that make up part of the sun’s light spectrum. The sun’s UV-C rays act as a natural outdoor air purification system, inhibiting the growth and reproduction of bacteria, viruses, fungi, molds, and dust mites. However, this natural process does not occur indoors. Ultraviolet radiation (UV-C) replicates the natural outdoor purification system of the sun by destroying the illness and disease-causing microbes living and multiplying in indoor air. In combination with a quality filter, it is the most effective way to reduce airborne contaminants and the health risks they represent.

Fungus Mold

Bacteria

Dust Mites

Field Controls 24v — Fungus Mold diagram (page 3)
Fig. 6 · Fungus Mold

Eliminate Moisture Problems Excessive moisture under a house can contribute to air pollution inside the house. The Eliminator® Foundation Vent Fan is a motorized fan designed for circulating outside air through the crawl space of a structure to reduce moisture and moisture-related problems. In addition to dry rot, fungus growth and increasing termite potential, excessive moisture can generate mold. Mold and mold spores can infiltrate the living space as well as the HVAC system, causing problems for the inhabitants.

With the Eliminator, air changes are increased dramatically for better moisture removal and control. The EL-1 is designed to be mounted to a crawl space vent. It operates off a temperature switch which activates the motor at or above 50°F. An optional, adjustable de-humidistat can be used to activate the unit at varying levels of relative humidity. This optional control can be wired in place of, or in series with, the standard temperature switch.

EL-1 Eliminator® · Foundation Vent Fan

Page 4 of the Field Controls 24v user manual — Fungus Mold
Page 4 · click to enlarge
Page 4
Field Controls 24v — Fungus Mold diagram (page 4)
Fig. 7 · Fungus Mold

Facts About Indoor Air

  • According to the Environmental Protection Agency, the air in homes can be up to 100 times more polluted than outdoor air. 1
  • Health effects may show up immediately, or after years of exposure to poor indoor air quality. These symptoms include some respiratory diseases, heart disease, and cancer. They may be severely debilitating or fatal. 3
  • The National Academy of Sciences Institute of Medicine reports that exposure to indoor pollutants is a key contributor to the asthma problems of this nation. 2
Field Controls 24v — Fungus Mold diagram (page 4)
Fig. 8 · Fungus Mold
Field Controls 24v — Fungus Mold diagram (page 4)
Fig. 9 · Fungus Mold
  • Most allergy and asthma sources are passed from person to person through the air.
  • The air in a single room can contain hundreds of thousands of infectious bacteria, viruses, fungal spores, and contaminants, which can only be seen with a microscope.
  • The disinfection of medical equipment using UV has been a common and reliable practice. 4
Field Controls 24v — Fungus Mold diagram (page 4)
Fig. 10 · Fungus Mold
  • UV disinfection has been determined to be adequate for inactivating bacteria and viruses. 5
  • The germicidal effects of UV light cause photochemical damage to DNA and RNA within microorganisms. 6
  • “...ultraviolet radiation, properly integrated with heating, ventilating, and air conditioning systems, shows the most promise as a widely applicable means of air disinfection.” Richard Riley, M.D. 7

* The UV-V wavelength generates ozone. According to the Environmental Protection Agency, ozone can be harmful to your health. When inhaled, ozone can damage the lungs. Relatively low amounts of ozone can cause chest pain, coughing, shortness of breath, and throat irritation. Ozone can also compromise your ability to fight respiratory infections. All UV-Aire lamps are coated to block this wavelength.

1. http://www.epa.gov/iaq/ - 5/16/01 2. http://www.epa.gov/iaq/asthma/intro/index.html#WhoGetsAsthma? - 5/16/01 3. http://www.epa.gov/iaq/ia-intro.html 4. “UVGI Design Basics” HPAC. January 2000. 5. EPA Guidance Manual Alternative Disinfectants and Oxidants. April 1999. 6. Jagger, J. 1967. Introduction to Research in Ultraviolet Photobiology. Prentice-Hall, Inc., Englewood Cliffs, NJ 7. Richard Riley, M.D. “Airborne Infection” The American Journal of Medicine, September 1974, Vol. 57

UV-16/24 w/transformer · Standard model · Facts About UV

Page 5 of the Field Controls 24v user manual — RETURN
Page 5 · click to enlarge
Page 5

®

How The In-duct UV-Aire Works

UV-Aire uses the energy from a specially designed, high-intensity UV-C lamp to reduce microorganisms in the entire home as they cycle through the HVAC system. Mounted inside the ductwork, the UV-Aire sterilizes or kills most contaminants as they pass the lamp.

Best Installation Location (down- stream of the A-coil) Coils and filters are breed- ing grounds for mold and bacteria. Installing the sys- tem here significantly reduces indoor air contaminants and new growth.

The process requires very little maintenance and costs just pennies a day to operate. The UV-Aire could be one of the best health and comfort investments a homeowner ever makes.

SUPPLY

A-Coil Installing UV-Aire near the coil helps maintain optimal efficiency of the HVAC system.

Indoor Air Treatment With UV

Field Controls 24v — SUPPLY diagram (page 5)
Fig. 11
Field Controls 24v — SUPPLY diagram (page 5)
Fig. 12

RETURN

UV’s effectiveness in killing bacteria is directly related to a microorganism’s exposure time. Indoor air in a typical residential forced-air HVAC system will be recirculated 40-75 times a day. With a UV generating lamp mounted in the HVAC duct, cumulative exposure can be very effective in controlling indoor bacteria.

UV rays will also kill germs that breed in drain pans and A-coils. Properly positioned, an ultraviolet system can significantly reduce indoor air contamination and prevent the growth of new microorganisms.

The treatment of indoor air with ultraviolet radiation has been successful in health care facilities, food processing plants, schools, laboratories and other applications. It is safe, silent, and proven.

Filter Systems Alone Don't Solve the Problem

The majority of indoor air is conditioned by forced-air heating and cooling (HVAC) systems. Standard fiber air filters are entirely ineffective in trapping germs, as most particles are simply too small, passing through the porous filter. New, high efficiency style filters will only capture airborne bacteria down to a certain size. These high efficiency filters are nominally effective, trapping small airborne contaminants on the filter, creating a breeding ground where germs can continue to grow and multiply.

Since direct exposure to UV light can cause skin cancer and blindness, the most practical application of UV light in the home or office is in the main air distribution (heating and/or air conditioning) system. As UV light will not pass through metal, glass, or plastic, a UV light can be installed in the main supply or return duct of a central heating or air system without concern for direct exposure to eyes or skin. This is an ideal location since the air in the home or office will pass through the HVAC system up to 75 times per day during normal operation, and as many as 150 times per day in continuous fan mode.

HVAC systems are a dark and damp breeding ground for mold and bacteria, particularly at the system filter and air conditioning A-coil. The buildup of matter on the A-coil and filter can significantly reduce the efficiency of the appliance by constricting and reducing air flow. This means increased cost to the homeowner in addition to the risk of airborne pollutants.

Ultraviolet Treatment Zone · Optional Installation Location

Page 6 of the Field Controls 24v user manual — Unique Features
Page 6 · click to enlarge
Page 6

®

(In-duct Models)

STANDARD MODELS UV-12, UV-18, UV-28, UV-12HP, UV-18HP, UV-28HP

Field Controls 24v — STANDARD MODELS UV-12, UV-18, UV-28, UV-12HP, UV-18HP, UV-28HP diagram (page 6)
Fig. 13

EXTERNAL MODELS UV-12E, UV-18E, UV-28E

Field Controls 24v — EXTERNAL MODELS UV-12E, UV-18E, UV-28E diagram (page 6)
Fig. 14
  • For outdoor installations
  • Ideal for any external package systems
  • For rooftop applications
  • Hard wired for 120V, 208V, or 240V
  • Hinged cover for easy accessibility
  • Includes patent pending angle bracket and duct board mounting kit
  • Installs easily and plugs into a standard 120V outlet
  • All UV-HP (heatpump) models are 240V
Field Controls 24v — EXTERNAL MODELS UV-12E, UV-18E, UV-28E diagram (page 6)
Fig. 15

NEW

REMOTE MODEL UV-16/120

Field Controls 24v — NEW diagram (page 6)
Fig. 16

DUAL LAMP MODEL UV-18X

  • 120 Volt Plugs into standard outlet
  • Compact Design Fits in tight spaces
  • Built-In Safety Switch Designed to light only inside the duct
  • E-Z Lamp Replacement Simple twist and lock
  • Double lamp maximizes intensity and effectiveness
  • Handles up to 4000 sq. ft.
  • Includes patent pending angle bracket and duct board mounting kit
  • Installs easily and plugs into a standard 120V outlet
Field Controls 24v — DUAL LAMP MODEL UV-18X diagram (page 6)
Fig. 17

NEW

CIRCUIT BOARD MODELS UV-12C, UV-18C, UV-28C, UV-12HPC, UV-18HPC, UV-28HPC

Field Controls 24v — NEW diagram (page 6)
Fig. 18

24 VOLT MODEL UV-16/24

  • 24V Plug-in Transformer Included No electrician required
  • Compact Design Fits in tight spaces
  • Built-In Safety Switch Designed to light only inside the duct
  • E-Z Lamp Replacement Simple twist and lock
  • Electronically monitors lamp life
  • Audible and visual lamp replacement alerts
  • Can wire into the thermostat to extend lamp life
  • Can link to existing security system
  • Includes all features of standard models
  • All UV-HPC (heatpump) models are 240V
Field Controls 24v — 24 VOLT MODEL UV-16/24 diagram (page 6)
Fig. 19

For maximum square footage and other details, see the Models and Specifications table.

All units are UL listed.

Unique Features

  • ANGLE BRACKET WITH SWIVEL ARM
  • Angle allows longer lamps to fit into smaller ductwork, maximizing effectiveness
  • Ensures the entire cross section of the duct is irradiated
  • Swivel arm allows for easy lamp replacement
  • Patented

IMPROVED LAMP OUTPUT • Technical enhancement improves intensity output over the life of the lamp

  • CIRCUIT BOARD TECHNOLOGY
  • Monitors performance and lamp life
  • Audible and visual lamp replacement alerts
  • Can link with existing security system
  • Can wire into the thermostat circuit
  • DUCT BOARD MOUNTING KIT
  • Makes mounting to duct board simple
  • Designed to increase stability on the duct board
Page 7 of the Field Controls 24v user manual — M
Page 7 · click to enlarge
Page 7

®

(Portable Models)

Field Controls 24v — ® diagram (page 7)
Fig. 20

UV-500C PORTABLE MODEL

  • Uses UV germicidal light, carbon, and high efficiency filtration
  • Quiet fan with three speed control
  • Purifies air in areas up to 500 square feet
  • Circuit board monitors lamp and filter life
  • Visual lamp and filter replacement alerts
  • Plugs into any standard 120V outlet
Field Controls 24v — UV-500C PORTABLE MODEL diagram (page 7)
Fig. 21

8” germicidal UV lamp

Visual lamp and filter condition alert

  • Replacement Kit
  • 4 high-efficiency/ carbon filters
  • 1 UV lamp
Field Controls 24v — UV-500C PORTABLE MODEL diagram (page 7)
Fig. 22

UV-1500C PORTABLE/WALL/CEILING MODEL

  • Purifies air in areas up to 1500 square feet
  • Sits on the floor, hangs on the wall, or installs in drop ceiling
  • Built-in fan with adjustable speed control
  • Circuit board technology monitors lamp life
  • Audible and visual lamp replacement alerts
  • Plugs into any standard 120V outlet
  • Uses UV germicidal light, carbon, and high efficiency filtration

M

Field Controls 24v — M diagram (page 7)
Fig. 23
Field Controls 24v — M diagram (page 7)
Fig. 24

12” germicidal UV lamp

Visual and audible lamp condition alert

12” x 12” high-efficiency/carbon filter

  • Replacement Kit
  • 1 carbon filter
  • 4 high-efficiency/ carbon filters
  • 1 UV lamp
Show 13 more labels / short text on this page
UV-500C Features · Built-in handles · 10”x10” high-efficiency/carbon filter · Adjustable fan control · Heavy-duty fan · Rubber feet · UV-1500C Features · Recessed handle · Carbon filter · Adjustable fan control · Heavy-duty fan · Rubber feet · Drop ceiling installation
Page 8 of the Field Controls 24v user manual — ®
Page 8 · click to enlarge
Page 8

®

For many years, ultraviolet light has proven effective in sterilizing medical equipment, purifying water, and processing food. Currently, the use of UV lights is gaining industry acceptance in HVAC applications. Microbe Management, Inc., a testing agency in

Greenville, NC, has conducted three separate tests to examine UV’s effect on indoor air quality. The test results conclude that UV is an integral part of a whole house approach to improving Indoor Air Quality.

While experts disagree on the root causes of many IAQ problems, there is consensus that stopping problems at the source is crucial to long-term air quality improvement. First, the homeowner must eliminate any unwanted sources of moisture in the home, such as roof leaks, drainage problems, and crawl space moisture.

The air conditioning coil must be addressed since it is a natural breeding ground for molds, which thrive in a

dark, moist environment. Familiar with the rank smell

generated when switching from air

conditioning to heat mode? That is the

Field Controls 24v — ® diagram (page 8)
Fig. 25

smell of mold and bio-film burning off

the coil. Whenever the blower is

engaged, mold spores from contaminated A-coils are released into the ductwork and distributed throughout the building. These spores then seek alternative surfaces in other parts of the home to breed and multiply.

EL-1 Eliminator Foundation Vent Fan

Surface TestUV Kills and Prevents Mold on A-Coils

A specific test was designed to determine UV’s effectiveness in treating mold on coil surfaces. The test simulated the damp, dark settings where A-coils are found.

unabated on the side without UV. Subsequently, the contaminated side was bathed in UV light and the mold was eradicated. Kane summarized the results: “Properly positioning a UV lamp over the A-coil in a residential or commercial air conditioning system can eliminate surface mold on the coil and prevent future mold growth as well.”

Field Controls 24v — ® diagram (page 8)
Fig. 26

In this study “We took a standard A-coil, sterilized it, introduced two kinds of mold, and then placed it in a controlled, moisture-laden environment,” says Bernard Kane, of Microbe Management. “We created two separate chambers in our lab. One chamber was bathed in UV light. The other was not.”

The results were dramatic and conclusive. The side of the A-coil that was exposed to the ultraviolet light was clean and clear of mold growth. Mold continued to grow

Airborne TestingSingle Pass and Cumulative Tests

Bacteria and viruses are introduced into the building by its occupants and often cannot be controlled at the source. Therefore, it is important to attack these airborne invaders early and often, before they have an opportunity to multiply. The single pass test proves that UV effectively kills these airborne microorganisms in the duct.

Since HVAC systems typically re-circulate the air 40-75 times per day, a multi-pass, cumulative test was also conducted. Results demonstrate that repeated, multi- pass exposure to UV light dramatically reduces the concentration of bacteria and viruses throughout the home.1

1. Efficiency of Bacterial Disinfection by a Duct-mounted UV-Aire ® Air Purifier: by Microbe Management

Independent Lab Testing · Attack the Source · Surface Test Results

Page 9 of the Field Controls 24v user manual — (Portable Models)
Page 9 · click to enlarge
Page 9
Field Controls 24v — (Portable Models) diagram (page 9)
Fig. 27 · (Portable Models)

This study introduced a common bacterium into a galvanized air duct equipped with a UV light to determine how effective the lamp would be in reducing the bacteria with one exposure, or a “single pass.” The tests were conducted at two speeds: 1125 cfm and

2250 cfm in an 18” x 18” duct. The UV lamp yielded at least a 90% reduction of the test bacteria with a single airflow pass at 1125 cfm, and at least 71% reduction at 2250 cfm.

Cumulative TestsMultiple Exposures Dramatically Improve IAQ

To further investigate the effectiveness of UV on indoor air quality, Microbe Management created a series of tests designed to measure the cumulative effect of UV in reducing airborne contaminants. The tests were performed in a structure with two isolated 8’ x 8’ x 8’ rooms where air could be sampled. In the control room, no UV was present, while the other room utilized a portable UV air purifier.

was reduced by 50% in just 10 minutes and by 98% within 30 minutes. In the control room, without UV, more than 85% of the bacteria were still active after thirty minutes.” Similarly, the leading consumer UV “tower” model was also tested, but showed only minimal effectiveness. (See chart below.)

Field Controls 24v — (Portable Models) diagram (page 9)
Fig. 28 · (Portable Models)

According to Bernard Kane, Ph. D., of Microbe Management, “Test results were very encouraging. In both rooms, we introduced a resistant, spore- forming bacteria until the air was saturated with 350 colonies per cubic foot. In the room with the portable UV unit, the spore count

ConclusionUV Is An Effective Part of “Whole House” Solution

A-coil irradiation, single pass, and cumulative tests confirm that UV is an important and effective contributor to a healthier home environment. UV technology used with a quality filter (MERV rated 8 or higher) will dramatically improve Indoor Air Quality. Additionally, portable units can be used in combination with in-duct models. This combination is strongly recommended for

individuals with depressed immune systems, asthma, allergies, or other respiratory conditions. For homes without forced-air, portable UV air purifiers are recommended to enhance IAQ. Also, health care professionals, teachers, and day-care workers can benefit from additional UV protection from influenza and other viruses.

Page 10 of the Field Controls 24v user manual — ®
Page 10 · click to enlarge
Page 10

®

UV Energy Required To Kill Bacteria

Correlating The Lab Test With Other Bacteria

Most, if not all bacteria can be destroyed by the use of UV light. The main factors in disinfection are the amount of UV power the lamp produces and the length of time the bacteria is exposed to the UV light source.

Use the chart below to estimate the effectiveness of the UV-Aire with other bacteria.

Harder–to–kill bacteria and molds require greater energy or exposure time to be as effective. For example, 99% reduction of Rotavirus requires 24,000 µW-sec/cm2 of UV energy versus 6,600 µW-sec/cm2 for Influenza virus (see table below). This means that Rotavirus spores are five times more resistant than Influenza. Consequently, spores will require five times the UV output energy from the lamp or five times greater exposure time. For practical purposes, we recommend trapping the spores in a high efficiency filter downstream of the UV-Aire which can be irradiated continuously with the UV-Aire lamp.

The energy required to kill microorganisms is a product of the UV light’s intensity and exposure time. This energy is measured in microwatt seconds per square centimeter.

Intensity x Exposure Time = microWatt seconds/cm2

Table 1 lists the amount of UV energy (measured in µW-sec/cm2) necessary to destroy various bacteria.

Independent lab testing of the UV-Aire shows that in a single-pass air flow test, one 18-inch UV-Aire lamp can reduce levels of Serratia Marcescens (a typical bacteria) by 93%, while a two lamp system can reduce by 99%.1

For details of the lab test ask for form number 4291.

1. Efficiency of Bacterial Disinfection by a Duct-mounted UV-Aire ® Air Purifier: by Microbe Management

The calculated average UV energy output levels of a single UV-Aire lamp in an 18-inch square duct is 2,608 µW-sec/cm2 and 6,186 µW-sec/cm2 for a two lamp system. The 6,186 is comparable to the 99% energy required for Serratia Marcescens. It can be seen that there is a direct correlation between the UV-Aire UV lamp output and the observed kill rates in the lab.

Bird Flu Virus (Avian Flu)

The Bird Flu Virus is a type of Influenza. Since the kill rate for the influenza virus is 6,600 microwatts of UV energy, it is reasonable to conclude that the Bird Flu virus can be reduced or eliminated by 6,600-10,000 microwatts.

UV dose required for the de-activation of various microbes BacteriaUV DoseMoldUV Dose Serratia Marcescens6,160Aspergillus amstelodami77,000 Legionnella bozemanii3,500Mucor Mucedo77,000 Legionnella micdadei3,100Penicillium chrysogenum56,000 Mycobacterium tuberculosis10,000YeastUV Dose Salmonella enteritidis7,600Baker's Yeast8,000 Salmonella typhi (Typhoid Fever)7,000Brewer's Yeast13,200 Streptococcus hemolyticus5,500UV dose is measured in microwatt seconds per centimeter squared (µW-sec/cm2). The information presented is intended to give the reader a general idea of how UV disinfects, based upon various credible resources. We do not guarantee its accuracy in any way. VirusUV Dose Adeno Virus Type III4,500 Infectious Hepatitis8,000 Influenza6,600 Rotavirus24,000

35" 1.4

39.97" 1

UV lamp intensity is rated at a distance of one meter. To determine the intensity of ultraviolet radiation at different distances from the lamp, multiply the intensity of the lamp by the intensity factor shown in the models and specifications chart.

Example: To determine the ultraviolet intensity of the UV-18 at a distance of six inches, multiply 73 by 20 to yield 1460 µW-sec/cm2.

Show 17 more labels / short text on this page
Lamp Intensity · Distance from Lamp · Intensity · Distance from Lamp · Intensity · Factor · Factor · 15" 6 · 1" 127 · 20" 4 · 2" 69 · 25" 3 · 4" 32 · 30" 2 · 6" 20 · 8" 14 · 10" 14
Page 11 of the Field Controls 24v user manual — (Portable Models)
Page 11 · click to enlarge
Page 11
Field Controls 24v — (Portable Models) diagram (page 11)
Fig. 29 · (Portable Models)
1. Insert the unit downstream from an A-coil in the supply plenum or downstream from the air filter in the return plenum. Mount base on duct using the enclosed mounting screws.
Field Controls 24v — (Portable Models) diagram (page 11)
Fig. 30 · (Portable Models)
2. Insert lamp through hole. Place bracket over end of tube and tighten wing nut.
3. Replace cover on unit and tighten side screw.

ALWAYS wear protective goggles to shield your eyes from UV damage when installing the UV-Aire.

UV-C can break down plastic material that is not UV resistant. Based on lab tests, positioning the lamp 30 inches or more away from plastic surfaces such as flex duct, drain pans, etc. will prevent any measurable break down.

4. Plug into 120V outlet & place rocker switch in “ON” position.
5. Switch will illuminate & blue glow can be seen through view port when unit is operating properly.

The UV-Aire can be installed in ducts nine inches and larger. Each unit comes with a duct board mounting kit and a patent- pending angle bracket. A dual lamp model is available for commercial applications and/or increased potency. There is also a model designed specifically for heat pumps and a model for outdoor installations.

GoodStandard Installation
BetterPatented Angled Installation - Single Lamp
Field Controls 24v — (Portable Models) diagram (page 11)
Fig. 31 · (Portable Models)
BestTwo Angled Lamps or Two Lamps Perpendicular
Field Controls 24v — (Portable Models) diagram (page 11)
Fig. 32 · (Portable Models)
Show 9 more labels / short text on this page
Installation · Installation Options · Good Better · 16" Duct · 16" Duct · 12" 18" · Best · 16" Duct · 18" 18"
Page 12 of the Field Controls 24v user manual — NEW
Page 12 · click to enlarge
Page 12

Minimum Duct Width Voltage Amps Hz Watts

1 meter µW/cm2 Product Warranty

Max. Sq. Ft.

9 14 22 9 14 22 9 14 22 9 14 22 9 14 22 14 NA NA120/208/240 120/208/240 120/208/240 120 120 120 240 240 240 120 120 1200.5 0.5 1.1 0.5 0.5 1.1 0.5 0.5 1.1 0.5 0.5 1.1 0.5 0.5 1.1 1.0 0.4 0.56030 30 60 30 30 60 30 30 60 30 30 60 30 30 60 60 36 30no yes no yes yes1500 2000 3000 1500 2000 3000 1500 2000 3000 1500 2000 3000 1500 2000 3000 4000 500 150037 73 105 37 73 105 37 73 105 37 73 105 37 73 105 2@73 24 37 UV-16/120 UV-16/2416 16120 240.5 1.360 6030 30no no2000 200062 625 yr 5 yr

NEW

space vent 120 0.6 60 35 - 1000 - 1 yr

Switch @120 12 max - 1 yr

* UV-18X includes two lamps. ** UV-E series includes aluminum NEMA 3 enclosures for external, outdoor installation. *** The EL-1 Eliminator and the EDH-1 De-Humidistat are not UV-Aire products but are recommended to help control and reduce moisture and moisture related problems in crawl spaces.

  • UV-1500C Replacement Kit
  • 1 carbon filter
  • 4 high-efficiency/ carbon filters
  • 1 UV lamp
  • UV-1500C Replacement Kit
  • 1 carbon filter
  • 4 high-efficiency/ carbon filters
  • 1 UV lamp
  • UV-500C Replacement Kit
  • 4 high-efficiency/ carbon filters
  • 1 UV lamp
  • UV-500C Replacement Kit
  • 4 high-efficiency/ carbon filters
  • 1 UV lamp
Field Controls 24v — NEW diagram (page 12)
Fig. 33

UV-Aire Germicidal Lamps • 8", 12", 16", 18" and 28"

Field Controls 24v — NEW diagram (page 12)
Fig. 34
  • UV-1500C Filter Pack
  • 1 carbon filter
  • 4 high-efficiency/ carbon filters
  • A one year supply
  • UV-500C Filter Pack
  • 4 high-efficiency/ carbon filters
  • A one year supply

It is important that lamps be replaced when the ultraviolet output falls below minimum requirements for protection. Even though a lamp will appear to be operating effectively because it still maintains the visible blue glow, the ultraviolet output will be significantly reduced after 9000 hours of use. To maintain maximum benefits, lamps should be replaced annually.

www.fieldcontrols.com

©2007 Field Controls form# 4283 Printed in U.S.A.(CP07) Field Controls, LLC | www.fieldcontrols.com | 2630 Airport Road | Kinston, NC 28504 | TEL: 252.522.3031 | FAX: 252.522.0214

Show 7 more labels / short text on this page
Models & Specifications · Circuit Board · Recommended · Lamp Intensity at · Model · EDH-1*** Humidity · Replacement Parts
Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Field Controls 24v

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Field Controls 24v

Be the first to ask — other owners or our team will answer.

Original document

Field Controls 24v manual PDF

12 pages·1.3 MB·Air Cleaner·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…