*Exclusive 5 position lamp mounting feature!

1-UV-Aire™ power unit 4-Sheet metal mounting screws 1-Angled mounting bracket 1-Flat mounting bracket 1-Duct board mounting bracket 1-Ultra Violet lamp 1-Instruction Sheet 1-Wing nut Caution Labels Gasket
UV-C light inhibits the growth and reproduction of germs and bacteria that circulate through a homes’ heating and air conditioning system. The treatment is a safe, silent, and proven way to make your home a healthier place to live.
READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION
LEAVE THE INSTALLATION INSTRUCTIONS WITH THE OWNER/OPERATOR OF THE DEVICE
AFTER OPENING THE CARTON, UNPACK AND INSPECT THE UNIT AND LAMP FOR DAMAGE.
DO NOT INSTALL THIS UNIT IF ANY DAMAGE IS NOTICEABLE.


This product is not sold as a medical device and is not for the purpose of diagnosis of any disease or condition nor for use in the mitigation, treatment, or prevention of any disease or condition. II. GENERAL INFORMATION
There are different size units available, depending on the square footage of your home. See chart below for determining your homes needs.

The UV-12C,18C,28C,12HPC,18HPC, and 28HPC units are equipped with a circuit board to monitor the operation of the UV lamp; it indicates the operation of the lamp through an LED indicator light mounted on the cover of the unit. The circuit board indicates good operation of the lamp by a continuous “GREEN” color on the LED light. After 8,320 hours of lamp operation, the circuit board indicates the elapsed time of lamp operation by a continuous “YELLOW” color on the LED light and the internal alarm will beep every 15 minutes. After 9,000 hours of lamp operation, the circuit board indicates the elapsed time of lamp operation by a continuous “RED” color on the LED light and the internal alarm will beep every 5 minutes. The board also checks if the UV lamp is burned out. If the lamp is burned out, the circuit board will indicate this by a continuous “RED” color on the LED and the internal alarm will beep every 5 minutes.
*Split system heat pumps are systems where the air handler and the air conditioning compressor are separate units.
**Packaged units are systems where the air handler and the air conditioning compressor are built together and are installed outside of the building




a. Apply supplied wet and stick mounting template to air duct
in either a vertical or horizontal position as shown in Figure 2.
b. Drill 1/8” diameter mounting holes at positions indicated on
template.
c. Cut out the marked openings on the template. (Refer to
template as shown in Figure 2)
d. Remove the paper template from the duct.
a. Mount the supplied metal mounting plate onto the duct with
duct tape in either a vertical or horizontal position (See Figure 2 & 3)
b. Bend tabs outward as shown in figure 4.
c. Using a knife or blade, cut out a rectangle opening in the duct using the mounting plate as a template. (See
d. Remove the cut piece of duct. (See Figure 6)
e. Bend both tabs down and through duct at first bend point. (See Figures 7& 8)
f. Bend both tabs at the second bend point up or down to pinch the duct material and grip the duct material. (See Figures 9 & 10)
g. Using a screwdriver or pointed object, locate mounting holes by poking holes through the duct tape. (See









a. Flat Bracket Installation
i. Remove the two hex nuts and flat bracket from included bagged hardware. ii. Install the flat bracket and secure to the unit base with the hex nuts provided. (See Figure 13)
b. Angled Bracket Installation

i. Remove the two hex nuts and angled bracket from included bagged hardware. ii. Install the angled bracket and secure to the unit base with the hex nuts provided. (See Figure 14) NOTE: Be sure to note location of lamp hole in bracket relative to unit base.









IV. INCORPORATING A THERMOSTAT (Be sure to follow any applicable state or local codes) The UV Aire units supplied with a circuit board allows for the automatic operation of the UV lamp when the there is a call for heating or cooling by the thermostat. After the call for heat has been satisfied, the UV Aire unit will operate for 45 minutes then shut off. 1. Turn off power switch on the UV Aire unit and unplug the unit before doing any wiring.




Diagram A

The UV Aire units supplied with a circuit board allows for the wiring of the UV Aire unit into an alarm or security system to monitor the operation of the UV lamp. This circuit is a set of normal open contacts that close if the operational time exceeds 9000 hrs or if the lamp burns out.




Diagram B

The UV-AIRETM units come with an angled mounting bracket and flat mounting bracket to position the bulb either straight or at an angle. Choose one or the other bracket method best suited for your needs. Refer to the configurations chart below when making your selection.

ANGLED LAMP MOUNTING BRACKET SPECIFICATIONS
Use the specifications below to determine allowable clearances for proper mounting of the UV-Aire™ unit on the duct.



Chart A

VERY IMPORTANT: Turn switch on unit to “OFF” position and unplug unit from outlet.

Timer Reset Button


For replacement parts, contact your local heating service company. Any questions, please contact Field Controls at:
For installations on duct systems with a metallic main duct and flex duct branches, follow the instructions in figure 26 below.


Limited Warranty Field Controls, L.L.C. warrants that the following Field Controls, L.L.C. products sold hereunder, shall be free from defects in material and workmanship under normal use for eighteen (18) months from date of manufacturing by the consumer excepting the provisions numbered below. UV-LAMPS/BULBS Field Controls, L.L.C. warrants that the following Field Controls, L.L.C. products sold hereunder, shall be free from defects in material and workmanship under normal use for ninety (90) days from date of installation by the consumer excepting the provisions numbered below. Provisions:
1. Field Controls shall have no obligation in the event the customer is unable to provide receipt showing the date the customer purchased the product(s) or accurate date code information. 2. The product must be properly installed, maintained and operated under normal conditions. 3. Field Controls shall not be liable for any consequential and incidental damages, resulting from failure of a Field Controls, L.L.C. product, failure to deliver, delay in delivery, delivery in nonconforming condition, or for any breech of contract or duty between Field Controls, L.L.C. and the customer. 4. Field Controls, L.L.C. products are often intended for use in specific applications. Field Controls, L.L.C. makes no warranty if a Field Controls, L.L.C. product is used in applications other than intended. 5. Field Controls, L.L.C. makes no warranty of any kind in regard to any other manufacturer’s products distributed by Field Controls, L.L.C. Field Controls, L.L.C. will pass on all warranties made by the manufacturer and where possible, will expedite the claim on behalf of the customer, but ultimately, responsibility for disposition of the warranty claim lies with the manufacturer.
The health aspects associated with the use of these products and their ability to aid in disinfecting of environmental air have not been investigated by UL.

P/N 46453400 Rev E 10/05