UV-AIRE™ AIR PURIFYING SYSTEM

Model: UV-12,18

Field Controls UV-12 — Model: UV-12,18 diagram (page 1)
Fig. 1 · Model: UV-12,18

ITEMS INCLUDED IN KIT:

1-UV-Aire™ power unit 4-Sheet metal mounting screws 1-Angled mounting bracket 1-Flat mounting bracket 1-Duct board mounting bracket 1-Ultra Violet lamp 1-Instruction Sheet 1-Wing nut Caution Labels Gasket

UV-C light inhibits the growth and reproduction of germs and bacteria that circulate through a homes’ heating and air conditioning system. The treatment is a safe, silent, and proven way to make your home a healthier place to live.

READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION

LEAVE THE INSTALLATION INSTRUCTIONS WITH THE OWNER/OPERATOR OF THE DEVICE

AFTER OPENING THE CARTON, UNPACK AND INSPECT THE UNIT AND LAMP FOR DAMAGE.

DO NOT INSTALL THIS UNIT IF ANY DAMAGE IS NOTICEABLE.

SAFETY CONSIDERATIONS

  • Looking directly at the UVC light may cause permanent eye damage or blindness.
  • Never operate the UV-Aire™ Air Purifying System out of the plenum .
  • Designed for a closed duct system. Do not mount near a supply or a return air opening
  • All duct openings in direct line of site of the UV light must be sealed with aluminum duct tape or equivalent sealing methods. WARNING: UV light will break down plastic materials not rated for UV exposure: (Examples: wire insulation, flex duct, drain pans and humidifiers)
  • The unit must be mounted at least 30” from the above stated type of materials.
  • If it is necessary to mount the unit in direct line of site of these types of materials, they must be shielded with aluminum foil, aluminum foil tape, or sheet metal. WARNING: DO NOT mount this unit outdoors.
  • This product is designed for indoor installation only (i.e. attics, crawl spaces, basements, etc.).
Field Controls UV-12 — SAFETY CONSIDERATIONS diagram (page 1)
Fig. 2
Page 2 of the Field Controls UV-12 user manual — III. INSTALLATION
Page 2 · click to enlarge
Page 2

I. INDICATION FOR USE

This product is not sold as a medical device and is not for the purpose of diagnosis of any disease or condition nor for use in the mitigation, treatment, or prevention of any disease or condition. II. GENERAL INFORMATION

There are different size units available, depending on the square footage of your home. See chart below for determining your homes needs.

ModelMinimum Duct Volts WidthAmpsMax A Hz Watts Tempir Lamp Intensity at 1 °F meterRecommended Max Sq. Feet UV-129 1200.560 30 190° 37 μW/cm21500 UV-1814 1200.560 30 190° 73 μW/cm22000

*Split system heat pumps are systems where the air handler and the air conditioning compressor are separate units.

**Packaged units are systems where the air handler and the air conditioning compressor are built together and are installed outside of the building

III. INSTALLATION

1. Locate a suitable location for the unit downstream from the ‘A’ coil in the supply plenum or in the return plenum; preferably downstream from the air filter. For optimum “cleaning” effect on the ‘A’ coil, mount the unit in the supply plenum as close as possible to the ‘A’ coil. (See Figure 1)
Field Controls UV-12 — III. INSTALLATION diagram (page 2)
Fig. 3
Page 3 of the Field Controls UV-12 user manual — I F YOU HAVE DUCT BOARD :
Page 3 · click to enlarge
Page 3
2. Determine the type of duct you have. (For flex duct applications, refer to Figure 21 on page 8)
Field Controls UV-12 — I F YOU HAVE METAL DUCT : diagram (page 3)
Fig. 4

I F YOU HAVE METAL DUCT :

a. Apply supplied wet and stick mounting template to air duct in

either a vertical or horizontal position as shown in Figure 2.

b. Drill 1/8” diameter mounting holes at positions indicated on

template.

c. Cut out the marked openings on template using a hole saw

or a pair of tin snips or jigsaw. (See Figure 2)

d. Remove paper template from duct.

I F YOU HAVE DUCT BOARD :

a. Mount the supplied metal mounting plate onto the duct with

duct tape in either a vertical or horizontal position as shown in Figure 2. (See Figure 3)

b. Bend tabs outward as shown in figure 4.

c. Using a knife or blade, cut out a rectangle opening in the duct using the mounting plate as a template. (See

d. Remove the cut piece of duct. (See Figure 6)

e. Bend both tabs down and through duct at first bend point. (See Figures 7 & 8)

f. Bend both tabs at the second bend point up or down to pinch the duct material and grip the duct material. (See Figures 9 & 10

g. Using a screwdriver or pointed object, locate mounting holes by poking holes through the duct tape. (See

Field Controls UV-12 — I F YOU HAVE DUCT BOARD : diagram (page 3)
Fig. 5
Field Controls UV-12 — I F YOU HAVE DUCT BOARD : diagram (page 3)
Fig. 6
Field Controls UV-12 — I F YOU HAVE DUCT BOARD : diagram (page 3)
Fig. 7
Field Controls UV-12 — I F YOU HAVE DUCT BOARD : diagram (page 3)
Fig. 8
Field Controls UV-12 — I F YOU HAVE DUCT BOARD : diagram (page 3)
Fig. 9
Field Controls UV-12 — I F YOU HAVE DUCT BOARD : diagram (page 3)
Fig. 10
Page 4 of the Field Controls UV-12 user manual — I F YOU HAVE METAL DUCT :
Page 4 · click to enlarge
Page 4
Field Controls UV-12 — I F YOU HAVE METAL DUCT : diagram (page 4)
Fig. 11
3. Remove base unit and cover from box.
4. Apply supplied “Duct Seal Kit” according to instructions included in kit (See Figure 12)
5. Determine whether to use flat or angled bracket. (Refer to UV-Aire “ Bulb Mounting Bracket Selection” in section IV for aid in this decision)
Field Controls UV-12 — I F YOU HAVE METAL DUCT : diagram (page 4)
Fig. 12

a. Flat Bracket Installation

i. Remove the two hex nuts and flat bracket from included bagged hardware. ii. Install the flat bracket and secure to the unit base with the hex nuts provided. (See Figure 13)

b. Angled Bracket Installation

Field Controls UV-12 — I F YOU HAVE METAL DUCT : diagram (page 4)
Fig. 13

i. Remove the two hex nuts and angled bracket from included bagged hardware. ii. Install the angled bracket and secure to the unit base with the hex nuts provided. (See Figure 14) NOTE: Be sure to note location of lamp hole in bracket relative to

unit base.

Field Controls UV-12 — I F YOU HAVE METAL DUCT : diagram (page 4)
Fig. 14
6. Mount the unit base to the duct using the four mounting screws provided. (See Figure 15)
7. Remove tag and alcohol wipe from lamp. Wipe off lamp being sure not to touch lamp with bare hands. The oils from your hands will reduce lamp output.
Page 5 of the Field Controls UV-12 user manual — I F YOU HAVE METAL DUCT :
Page 5 · click to enlarge
Page 5
Field Controls UV-12 — I F YOU HAVE METAL DUCT : diagram (page 5)
Fig. 15
8. Insert lamp through hole until lamp cannot be inserted any further. (See Figure 16)
9. Swing the swivel bracket over end of lamp. Hand-tighten the wing nut on stud. (See Figure 17) Be careful not to over tighten the wing nut. The porcelain at the lamp base may crack when over tightened.
Field Controls UV-12 — I F YOU HAVE METAL DUCT : diagram (page 5)
Fig. 16
Field Controls UV-12 — I F YOU HAVE METAL DUCT : diagram (page 5)
Fig. 17
10. Plug ballast plug into end of lamp. (See Figure 18)
11. Snap cover onto the unit base. Close the cover and tighten cover screw. (See Figure 19 & 20)
Field Controls UV-12 — I F YOU HAVE METAL DUCT : diagram (page 5)
Fig. 18
Field Controls UV-12 — I F YOU HAVE METAL DUCT : diagram (page 5)
Fig. 19
12. Plug the power cord into a standard electrical outlet.
13. Press the power switch to the ‘ON’ position. (Light on switch should be on indicating power.)
14. Look through view port in the box cover to be sure lamp is working. You should see a blue glow. (The view port is covered with a plastic lens that blocks the UVC rays.)
15. If the lamp is not glowing, follow steps 8-14 again. If lamp still does not glow, contact technical support at 1-252522-3031 for further assistance.
Page 6 of the Field Controls UV-12 user manual — IV. BULB MOUNTING BRACKET SELECTION
Page 6 · click to enlarge
Page 6

IV. BULB MOUNTING BRACKET SELECTION

The UV-AIRETM units come with an angled mounting bracket and flat mounting bracket to position the bulb either straight or at an angle. Choose one or the other bracket method best suited for your needs. Refer to the configurations chart below when making your selection.

Field Controls UV-12 — IV. BULB MOUNTING BRACKET SELECTION diagram (page 6)
Fig. 20

ANGLED LAMP MOUNTING BRACKET SPECIFICATIONS

Use the specifications below to determine allowable clearances for proper mounting of the UV-Aire™ unit on the duct.

Field Controls UV-12 — IV. BULB MOUNTING BRACKET SELECTION diagram (page 6)
Fig. 21
Chart B LAMP OFFSET DIMENSIONS UnitMin Duct Size (inches)AB V-129x128-1/26-1/2 V-1814x1813-1/210-5/16
Page 7 of the Field Controls UV-12 user manual — VIII. REPLACEMENT PARTS LIST
Page 7 · click to enlarge
Page 7

V. MAINTENANCE

1. Inspect and clean lamp at least every 6 months.
2. Replace your UV-Aire™ Air Purifying System lamp once a year to maintain the lamps maximum output intensity. The lamp should operate continuously for maximum lamp life and light effectiveness.

VI. LAMP REPLACEMENT PROCEDURE

VERY IMPORTANT: Turn switch on unit to ‘OFF’ position and unplug unit from outlet.

1. Loosen the cover screw on the side of the unit and open cover.
2. Unplug ballast plug from end of lamp.
3. Loosen the wing nut on swivel bracket and rotate the bracket clockwise.
4. Slide lamp out carefully.
5. Insert the lamp through the mounting hole and secure the lamp by rotating the swivel bracket counter-clockwise into position and secure by tightening wing nut. Be careful not to over tighten the wing nut.
6. Attach the ballast plug onto the end of the lamp.
7. After replacing lamp, make sure a new Lamp Replacement Label (supplied with lamp replacement) is applied to the housing and dated with the date of installation.

VII. TROUBLESHOOTING GUIDE

1. If the lamp does not light up, replace the lamp.
2. If the lamp still does not light up after replacing the lamp, replace ballast.

VIII. REPLACEMENT PARTS LIST

MODELLAMPBALLAST (Field Controls Part Number)(Field Controls Part Number) UV-124636540146365508 UV-184636540246365509

For replacement parts, contact your local heating service company. Any questions, please contact Field Controls at:

Phone252-522-3031 Fax: 252-522-0214 Email: sales@ fieldcontrols.com
Page 8 of the Field Controls UV-12 user manual — Limited Warranty
Page 8 · click to enlarge
Page 8

IX. FLEX DUCT INSTALLATION

For installations on duct systems with a metallic main duct and flex duct branches, follow the instructions in figure 21 below.

Limited Warranty

Field Controls, L.L.C. warrants that the following Field Controls, L.L.C. products sold hereunder, shall be free from defects in material and workmanship under normal use for eighteen (18) months from date of manufacturing by the consumer excepting the provisions numbered below. UV-LAMPS/BULBS Field Controls, L.L.C. warrants that the following Field Controls, L.L.C. products sold hereunder, shall be free from defects in material and workmanship under normal use for ninety (90) days from date of installation by the consumer excepting the provisions numbered below. Provisions:

1. Field Controls shall have no obligation in the event the customer is unable to provide receipt showing the date the customer purchased the product(s) or accurate date code information. 2. The product must be properly installed, maintained and operated under normal conditions. 3. Field Controls shall not be liable for any consequential and incidental damages, resulting from failure of a Field Controls, L.L.C. product, failure to deliver, delay in delivery, delivery in nonconforming condition, or for any breech of contract or duty between Field Controls, L.L.C. and the customer. 4. Field Controls, L.L.C. products are often intended for use in specific applications. Field Controls, L.L.C. makes no warranty if a Field Controls, L.L.C. product is used in applications other than intended. 5. Field Controls, L.L.C. makes no warranty of any kind in regard to any other manufacturer’s products distributed by Field Controls, L.L.C. Field Controls, L.L.C. will pass on all warranties made by the manufacturer and where possible, will expedite the claim on behalf of the customer, but ultimately, responsibility for disposition of the warranty claim lies with the manufacturer.

The health aspects associated with the use of these products and their ability to aid in disinfecting of environmental air have not been investigated by UL.

Field Controls UV-12 — Limited Warranty diagram (page 8)
Fig. 22 · Limited Warranty

P/N 46360900 Rev N 09/04

Ask about the Field Controls UV-12

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.