Installation Guide

Hardware Platform 10

FChwp10

Page 2 of the Field Controls Draft Regulator (10) user manual — Installation Guide
Page 2 · click to enlarge
Page 2
Page 2 of the Field Controls Draft Regulator (10) user manual — Installation Guide
Page 3 of the Field Controls Draft Regulator (10) user manual — Installation Warning
Page 3 · click to enlarge
Page 3

Safety Information

The following are warnings or safety guidelines. A warning means danger. You are in a situation that could cause bodily injury. Before you work on any equipment, be aware of the hazards involved with electrical circuitry and be familiar with standard practices for preventing accidents.

Qualified Personnel Warning

Only trained and qualified personnel should install or replace the device.

Varoitus Ainoastaan koulutettu ja pätevä henkilökunta saa asentaa tai vaihtaa tämän laitteen.

Advarsel Kun kvalifisert personell med riktig opplæring bør montere eller bytte ut dette utstyret.

¡¡Atencióón! Estos equipos deben ser instalados y reemplazados exclusivamente por personal téécnico adecuadamente preparado y capacitado.

Varning! Denna utrustning ska endast installeras och bytas ut av utbildad och kvalificerad personal.

Installation Warning

Read the installation instructions before you connect the device to a power source.

Varoitus Lue asennusohjeet ennen järjestelmän yhdistämistä virtalähteeseen.

Advarsel Les installasjonsinstruksjonene før systemet kobles til strømkilden.

¡¡Atencióón! Ver las instrucciones de instalación antes de conectar el sistema a la red de alimentación.

Varning! Läs installationsanvisningarna innan du kopplar systemet till dess strömförsörjningsenhet.

Page 4 of the Field Controls Draft Regulator (10) user manual — Software License Terms (End User License Agreement)
Page 4 · click to enlarge
Page 4

Restricted Access Area Warning

The device is intended for installation in restricted access areas. A restricted access area is an area to which access can be gained only by service personnel through the use of a special tool, lock and key, or other means of security, and that is controlled by the authority responsible for the location.

Varoitus Tämä laite on tarkoitettu asennettavaksi paikkaan, johon pääsy on rajoitettua. Paikka, johon pääsy on rajoitettua, tarkoittaa paikkaa, johon vain huoltohenkilöstö pääsee jonkin erikoistyökalun, lukkoon sopivan avaimen tai jonkin muun turvalaitteen avulla ja joka on paikasta vastuussa olevien toimivaltaisten henkilöiden valvoma.

Advarsel Denne enheten er laget for installasjon i områder med begrenset adgang. Et område med begrenset adgang gir kun adgang til servicepersonale som bruker et spesielt verktøy, lås og nøkkel, eller en annen sikkerhetsanordning, og det kontrolleres av den autoriteten som er ansvarlig for området.

Varning! Denna enhet är avsedd för installation i områden med begränsat tillträde. Ett område med begränsat tillträde får endast tillträdas av servicepersonal med ett speciellt verktyg, lås och nyckel, eller annan säkerhetsanordning, och kontrolleras av den auktoritet som ansvarar för området.

Disclaimer

The information in this manual has been carefully checked and is believed to be accurate. CER assumes no responsibility for any infringements or patents or other rights of third parties that may result from its use. CER assumes no responsibility for any inaccuracies that may be contained in this document. CER makes no commitment to update or keep current the information in this manual. CER reserves the right to make improvements to this document and/or products at any time and without notice.

Software License Terms (End User License Agreement)

This device contains software. The software is licensed ! Read the software licensen terms and check the User’s Guide for detailed info.

Page 5 of the Field Controls Draft Regulator (10) user manual — Device handling
Page 5 · click to enlarge
Page 5

Power Supply Disconnection Warning

Before working on the device or near power supplies, disconnect the power.

Varoitus Kytke irti vaihtovirtalaitteiden virtajohto ja katkaise tasavirtalaitteiden virta suojakytkimellä, ennen kuin teet mitään asennuspohjalle tai työskentelet virtalähteiden läheisyydessä.

Advarsel Før det utføres arbeid på kabinettet eller det arbeides i nærheten av str¿mforsyningsenheter, skal str¿mledningen trekkes ut p vekselstrømsenheter og strømmen kobles fra ved strømbryteren på likestrømsenheter.

¡¡Advertencia! Antes de manipular el chasis de un equipo o trabajar cerca de una fuente de alimentación, desenchufar el cable de alimentación en los equipos de corriente alterna (CA); cortar la alimentación desde el interruptor automático en los equipos de corriente continua (CC).

Varning! Innan du arbetar med ett chassi eller nära strömförsörjningsenheter skall du för växelströmsenheter dra ur nätsladden och för likströmsenheter bryta strömmen vid överspänningsskyddet.

Device handling

Anti-Static handling The device contains CMOS devices that could be damaged in the venet of static electricity discharged through them. At all times use anti static precautions when handling the device.

Battery This device contains a non-rechargebale battery. Do not short-cut the battery. Please ensure that if the battery is replaced that the new part conforms to the same specifications.

Electromagnetic Compatibility (EMC) The EWS1700 is classified as a component with regards to the European Community EMC regulations and it is the users responsibility to ensure that systems using this device are compliant with the appropiate EMC standards.

Packaging Please ensure that if a device should be returned to CER, it is adequately packed, preferable in the original packing material.

Page 6 of the Field Controls Draft Regulator (10) user manual — Power Supply Disconnection Warning
Page 6 · click to enlarge
Page 6
Page 6 of the Field Controls Draft Regulator (10) user manual — Power Supply Disconnection Warning
Page 7 of the Field Controls Draft Regulator (10) user manual — About this manual
Page 7 · click to enlarge
Page 7

About this manual

This document is intended for users of the FieldCommander, ELS- or EWS controllers that are based on the HWP10-platform and explains the steps to install and setup the system in your environment.

This guide contains information to install and configure the unit in your networking environment, as well as a basic overview of the serial communication hardware and IP- addressing. It provides all knowledge needed to connect the device in a way that the CER controller is accessible and ready for further use.

Organisation of the documentation

Installation Installation Guide Hardware Platform 10 (FCHWP10IG) Bundles information related to the hardware, such as the installation of the device, IP networking, serial interface details and technical specifications.

For ELS controllers: Employment Software User's Guide (ELSSWUG) Explains the configuration of the ELS controller.

For EWS controllers: Employment Software User's Guide (EWSSWUG) Explains the configuration of the EWS controller.

For FieldCommander controllers: Employment Software User's Guide (FCSWUG) Explains how FieldCommander is used in your application development, and documents all its features, including the configuration.

Programming FCscript Programmer's Guide (FCSCRPG) Function reference of FieldCommander's scripting language, used to create control applications.

FCphp Programmer's Guide (FCPHPPG) Function descriptions of the FieldCommander specific PHP interface, used to build dynamic user interfaces on top of the control application.

Software options Modbus Software Option (FCOPT010) Galaxy Software Option ( FCOPT020) The "option" modules have their own documentation to explain the features, installation, configuration and programming interfaces.

References Javascript Reference Manual (FCJSREF) Extensive documentation of the Javascript (ECMAscript) core language used by FieldCommander for application programming.

PHP Language Manual Complete documentation of the PHP language and functions.

About this manual

Page 8 of the Field Controls Draft Regulator (10) user manual — Getting familiar
Page 8 · click to enlarge
Page 8

Installation

This chapter explains the installation in detail and along the way it introduces you to some of the concepts important to understand the operation of your controller unit.

System requirements

In order to connect to the controller, you need a valid TCP/IP network connection and a browser. To be complete, it requires:

  • 10Mbit (10base-T) or 100Mbit (100base-T) network connection with RJ-45 socket
  • operating system with TCP/IP protocol stack
  • Internet browser

CER International releases firmware updates regularly with enhancements, changes and fixes. Updates may feature new functionality, so it is a good idea to occasionally check the website at http://www.cer.com for new firmware releases.

Getting familiar

In this chapter we describe the connectors of your controller. Depending on the product model all controls are located on the front of the unit, or controls are on both sides:

Field Controls Draft Regulator (10) — Getting familiar diagram (page 8)
Fig. 4 · Getting familiar

The 9-pin port is used to connect your controller to your serial equipment. The chapter called "Serial Interface" uncovers the details of serial communication and pin-out of the connector.

The CER controller is equipped with an Ethernet LAN controller that is fully compliant with IEEE 802.3 10/100Base-T CSMA/CD standards. The Ethernet port provides a standard RJ-45 jack on board. After completion of the startup process, two LED indicators provide information about the status of the network connection. The Green LED (right) indicates that there is a physical connection (link) to the network. The Green LED (left) indicates network activity. It flashes when there is any data on the line; it's not necessarily addressed to the controller.

This connector implements a passive power over Ethernet scheme, using the two unused pairs. More about this can be found in the section ‘Power over Ethernet’ in the next chapter.

Show 4 more labels / short text on this page
Front · Ethernet Power RS232 · Serial port · Ethernet connector
Page 9 of the Field Controls Draft Regulator (10) user manual — RS232/RS485 RS232 USB
Page 9 · click to enlarge
Page 9

LED indicator Next to the Power Connector there is a green LED on the front panel for indicating system status. This LED is lit when power is supplied to the unit.

Power to the controller is accommodated by a DC jack “J9” or by passive power over ethernet connector. The DC jack is attached to a 18V external DC power supply. Power supplied to the unit must be within the specifications listed in this manual.

Field Controls Draft Regulator (10) — USB diagram (page 9)
Fig. 5

USB

Field Controls Draft Regulator (10) — USB diagram (page 9)
Fig. 6

RS232/RS485 USB

Field Controls Draft Regulator (10) — RS232/RS485 USB diagram (page 9)
Fig. 7

RS232/RS485 RS232 USB

Show 6 more labels / short text on this page
Installation · Power connector · Back · (FC2700/FC3700 only) · (FC372x only) · (FC373x only)
Page 10 of the Field Controls Draft Regulator (10) user manual — USB
Page 10 · click to enlarge
Page 10

(ELS1700 or EWS1700 only)

Field Controls Draft Regulator (10) — USB diagram (page 10)
Fig. 8

(ELS172x only) To be defined !!

The 9-pin port is used to connect your controller to your serial equipment. The chapter called "Serial Interface" uncovers the details of serial communication and pin-out of the connector.

The back panel features two USB connectors.

The affixed label on the back of the unit states the products serial number which is identical to its MAC address.

Show 6 more labels / short text on this page
VGA Audio USB · VGA Audio USB · Serial port · USB connectors · Bottom · Serial Number
Page 11 of the Field Controls Draft Regulator (10) user manual — Hardware installation
Page 11 · click to enlarge
Page 11

Hardware installation

You communicate with the controller over the Ethernet network. In this part of the chapter, you'll learn about the unit itself and how and where to connect it. There are no configurable parts inside. Everything is controlled and configured by the software.

  • You can use the controller in several places, depending on your needs:
  • freely (unfixed) on your desktop with the included adhesive plastic bumpers.
  • fixed to a DIN-rail using the supplied DIN-rail clips. These can be inserted into the holes in the case. Be sure to position the rebated joints at the outside of the Controller for easy removal of the case from the DIN-rail in the future.
  • if outdoor option: fixed to a wall or 1" mast using the waterproof NEMA-67 outdoor case

The controller requires power of a single 7-18VDC. The power consumption is rated at 12VDC/0.25ATYP and 12VDC/0.4AMAX. This can be applied using a Power adaptor or Power Over Ethernet.

Follow these steps to connect the controller to your power supply: 1. Make sure the power supply is unplugged 2. Connect the DC jack to your controller Now you can safely plug in your power supply. Notice that the PWR indicator lights up.

Show 4 more labels / short text on this page
Installation · Physical installation · Connecting power · Power adaptor
Page 12 of the Field Controls Draft Regulator (10) user manual — LAN
Page 12 · click to enlarge
Page 12

In your controller a passive power over Ethernet (PoE) scheme is implemented (see below), using the unused pairs of the LAN port for power.

Field Controls Draft Regulator (10) — LAN diagram (page 12)
Fig. 9

Power can be injected using passive POE splitter which can be ordered seperately.

LAN

POE

Power Over Ethernet · POE Splitter FieldCommander · Power

Page 13 of the Field Controls Draft Regulator (10) user manual — LAN
Page 13 · click to enlarge
Page 13

Connecting to the network

Before connecting the controller to the network, you might want to consult your network administrator. You can employ the controller at various points in your ethernet network as shown below.

Make sure the IP addressing scheme of your controller does not interfere with your existing network configuration. The chapter "IP configuration" takes the myths out of it.

Three ways to connect your controller to Ethernet:

Local LAN Remote WAN

Field Controls Draft Regulator (10) — LAN diagram (page 13)
Fig. 10
Field Controls Draft Regulator (10) — LAN diagram (page 13)
Fig. 11

Local LAN: The controller is part of the local Ethernet network by connecting it to the hub or switch using a straight cable, just like your own workstation.

Remote WAN: When you co-locate the controller, you can connect to it through a public network like the Internet. In this case, the controller is connected to the network through your Internet gateway/router with Port Forwarding support using the supplied straight cable. The gateway/router establishes the connection between your ISP and the controller.

Point-to-Point: You can connect the controller to your workstation directly using a crossed ethernet cable (not supplied). Use this setup where you don't have a Ethernet LAN available or when you don't want to use it for the controller.

Decide first where you want to connect the CER controller as it affects some of the steps in the installation, most importantly cabling requirements and IP configuration.

Installation · Point-to-Point

Page 14 of the Field Controls Draft Regulator (10) user manual — LAN
Page 14 · click to enlarge
Page 14

To connect the CER controller to your 10/100base-T network, you can use any standard Category 5 (CAT5). A suitable cable is supplied. Attach one side to the RJ-45 socket marked "Ethernet" on the front panel of the unit and the other to your ethernet hub or switch.

Take note of the serial number of your CER controller for future reference during installation. You find the number on the label on the back of the unit.

Page 15 of the Field Controls Draft Regulator (10) user manual — Addressing basics
Page 15 · click to enlarge
Page 15

IP configuration

Your CER controller uses the common TCP/IP protocols to provide the connection to the client machine over Ethernet. Like any server or device, it needs a 'unique' IP number to be addressed. This chapter shows the basic concepts necessary to install and operate the controller, it does not intend to be a TCP/IP networking guide.

Addressing basics

Every device attached to a TCP/IP network is identified by a unique IP address which is a 32-bit number. To make it easier to memorize such addresses, they are usually expressed as four 8-bit numbers between 0 and 255, seperated by dots, e.g.: 192.168.4.1. There are restrictions on using 0 and 255 so avoid those in an address.

Although an IP address is a single value, it consists of two parts: the network ID and the host ID of your computer. The network ID identifies the systems located on the same physical network. The host ID identifies a workstation, server, router, or other TCP/IP device within the network.

Even if a network is not connected to the Internet, it has become custom to choose an address in a range reserved for private networks. That makes it possible to connect your private network to the Internet later without having to reconfigure. The following ranges are reserved for local use (taken from RFC 1597):

10.0.0.0 to 10.255.255.255 172.16.0.0 to 172.31.255.255 192.168.0.0 to 192.168.255.255

After receiving a network ID from your system administrator, you must pick a unique ID for your CER controller. Three classes are defined to accommodate networks of varying sizes. The address class can be identified by the first octet of the address or network ID. The examples in the table below use w.x.y.z to designate the bytes of the IP address.

Class w values Network ID Host ID Subnet mask

A 1-126 w x.y.z 255.0.0.0

B 128-191 w.x y.z 255.255.0.0

C 192-223 w.x.y z 255.255.255.0

Subnet masks are 32-bit values that allow the recipient of IP packets to distinguish the network ID portion from the host ID. Subnet masks are created by assigning 1's to network ID bits and 0's to host ID bits. The 32-bit value is then converted to dotted-decimal notation, as shown in the table. For example, when the IP address is 192.168.4.1 and the subnet mask is 255.255.0.0, the network ID is 192.168 and the host ID is 4.1.

To prevent addressing and routing problems, all computers on a logical network must use the same subnet mask and network ID.

IP configuration · Unique address · Classes and subnets

Page 16 of the Field Controls Draft Regulator (10) user manual — Assigning an IP address on a FieldCommander
Page 16 · click to enlarge
Page 16

For FieldCommander controllers:

Assigning an IP address on a FieldCommander

The factory default IP address of the controller is: 10.0.0.1 with netmask 255.0.0.0.

This address will suffice when you have a point-to-point connection with the controller or when the local network ID is "10". In this case the host ID of the controller already fits in in the range from 10.0.0.0 to 10.255.255.255. In any other case you'll have to assign your controller a new IP address.

Configure IP address with browser

The normal way is to change the IP address, netmask and/or default gateway is from a web browser. For this to work, the computer with the browser must be on the same subnet. When this is not the case you can force the controller to accept a new IP address by way of ARP and PING commands, see later this chapter.

To open the configuration pages of FieldCommander, start your web browser and enter FieldCommander's IP address in the location/address field: http://10.0.0.1/admin/

The Login page should now appear:

Field Controls Draft Regulator (10) — Assigning an IP address on a FieldCommander diagram (page 16)
Fig. 12 · Assigning an IP address on a FieldCommander

When the above page does not appear, test the connection with PING (see next chapter).

Page 17 of the Field Controls Draft Regulator (10) user manual — Assigning an IP address on a FieldCommander
Page 17 · click to enlarge
Page 17

In case you forgot the address of FieldCommander, you can force it to accept a new IP address by way of ARP and PING commands, see later this chapter.

Now you should identify yourself before you can access any of the actual configuration pages. Log in with the preconfigured "admin" account:

User nameadmin Password: admin

See the User's Guide for instructions.

Field Controls Draft Regulator (10) — Assigning an IP address on a FieldCommander diagram (page 17)
Fig. 13 · Assigning an IP address on a FieldCommander

After logging in, the "General" page shows the following information:

Status: indicates whether or not a script is running Host name: network name of the unit IP address: IP network address assigned to this unit (currently: 10.0.0.1) Product model: the product type identification of the unit Software version: currently installed firmware version Serial number: unique serial identification also printed on the unit Logged in as: name of the user currently logged in (currently: admin)

The configuration system is split into several tabs. The User's Guide explains the web user interface in detail, here we only discuss the system's IP settings

Click the "System" tab to go to the System page.

IP configuration

Page 18 of the Field Controls Draft Regulator (10) user manual — Assigning an IP address on a FieldCommander
Page 18 · click to enlarge
Page 18

The "System IP" page shows the following information:

Field Controls Draft Regulator (10) — Assigning an IP address on a FieldCommander diagram (page 18)
Fig. 14 · Assigning an IP address on a FieldCommander
IPInternet Protocol DHCP: Dynamic Host Configuration Protocol Bootp: Bootstrap Protocol ARP: Address Resolution Protocol

These fields control the IP settings of FieldCommander:

In situations where you don't have access to your FieldCommander unit or you have lost its address, ARP+PING provides a solution to change it from your workstation, see next chapter. When you uncheck the box, this feature is disabled which may lock you out of FieldCommander so do not uncheck this box unless you know what you are doing.

Fill out the new IP address, subnet mask and default gateway/router address here. Set the default gateway to 127.0.0.1 when you are not using a gateway or router or you don't know what it is. For details about the addressing, see chapter "IP configuration".

Instead of manually configuring the IP addresses, they can be assigned automatically using DHCP and bootp. Consult your network administrator if there is a DHCP or bootp server present. Don't use this setting unless you know exactly what your are doing.

You have to restart the system in order for the new settings to take effect. Note that you have to point your browser to the new address and log in again when you've changed IP settings.

Enable ARP+PING · Manual IP settings · DHCP/bootp server

Page 19 of the Field Controls Draft Regulator (10) user manual — Assigning an IP address on a FieldCommander
Page 19 · click to enlarge
Page 19

Force new IP address using ARP+PING

When FieldCommander is outside of your subnet or or you don't recall it's current address, you cannot open the configuration web pages to change the IP settings. To solve this, you can force FieldCommander to accept a new IP address by way of ARP and PING commands.

To force a new IP address into FieldCommander, start a command prompt and type the following commands:

arp -s ping

Example:

arp -s 192.168.4.1 00-d0-c9-48-29-77 ping 192.168.4.1

The response will be something similar to the following:

Request timed out. Reply from 192.168.4.1: bytes=32 time=1ms TTL=128 Reply from 192.168.4.1: bytes=32 time

The new address takes effect immediately and you can access FieldCommander with that IP address through your browser right away. You will now have to use the web browser to make permanent changes to the IP configuration.

Unix, Linux and OS/2

"arp" is part of the net-tools package in Unix and Linux so you might need to install this first.

To force a new IP address into FieldCommander, type the following commands:

arp -s temp ping

Example:

arp -s 192.168.4.1 00-d0-c9-48-29-77 temp ping 192.168.4.1

You will see a response similar to this:

64 bytes from 192.168.4.1icmp_seq=1 ttl=255 time=50 usec 64 bytes from 192.168.4.1: icmp_seq=2 ttl=255 time=53 usec

The new address takes effect immediately and you can access FieldCommander with that IP address through your browser right away. You will now have to use the web browser to make permanent changes to the IP configuration.

IP configuration · Windows 95/98/ME/NT/2000/XP

Page 20 of the Field Controls Draft Regulator (10) user manual — Assigning an IP address on an ELS controller
Page 20 · click to enlarge
Page 20

For ELS controllers:

Assigning an IP address on an ELS controller

The IP address on an ELS controller is defined in a configuration file and set to 10.0.0.1 by default.

To change this IP address, connect to the ELS using an USB keyboard, SSH or the serial console. Then log in using username / password (default els / elsroot) and edit the file /etc/network/interfaces

DHCPauto eth* iface eth* inet dhcp

Fixed IP (10.0.0.1): auto eth* iface eth* inet static address 10.0.0.1 gateway 127.0.0.1 netmask 255.0.0.0 network 10.0.0.0 broadcast 10.0.0.255

The ELS must be rebooted for the changes to take affect.

Page 21 of the Field Controls Draft Regulator (10) user manual — Assigning an IP address on an EWS controller
Page 21 · click to enlarge
Page 21

For EWS controllers:

Assigning an IP address on an EWS controller

The IP address on an EWS controller is defined in a configuration file and set to 10.0.0.1 by default.

To change this IP address, connect to the ELS using an USB keyboard, SSH or the serial console. Then log in using username / password (default els / elsroot) and edit the file /etc/network/interfaces

DHCPauto eth* iface eth* inet dhcp

Fixed IP (10.0.0.1): auto eth* iface eth* inet static address 10.0.0.1 gateway 127.0.0.1 netmask 255.0.0.0 network 10.0.0.0 broadcast 10.0.0.255

The EWS must be rebooted for the changes to take affect.

IP configuration

Page 22 of the Field Controls Draft Regulator (10) user manual — Testing the Ethernet connection
Page 22 · click to enlarge
Page 22

Testing the Ethernet connection

The most basic way to test the network connection is to do a so-called 'ping' test. When the connection is working, the CER controller will answer with an 'echo' or 'pong'.

Start a command prompt on your local machine and type the following command:

Example:

ping 10.0.0.1

The response will be something similar to the following:

Reply from 10.0.0.1: bytes=32 time=1ms TTL=128 Reply from 10.0.0.1: bytes=32 time=1ms TTL=128 ...

This means the Ethernet connection is working and the IP settings are correct. You should be able to open the web page with your browser, see next text.

However, if PING displays something like:

Request timed out. Request timed out

It appears that your system did not receive a response back. Maybe the unit is configured to a different address, or you have a hardware problem. You can try to ping another machine to test if the cabling and network configuration is correct. When it fails, check the cabling and network setup.

In case you see a response like:

Destination host unreachable.

This indicates that the address you try to ping is outside of your subnet and you did not define a correct gateway/router address on the machine. Fix the IP settings of your machine and try pinging again. Note that you might have to restart your machine first.

When the ping test has passed, start a web browser on your local machine and enter the current IP address of your CER controller in the location/address field:

http://10.0.0.1/admin/

The Login page should now appear (see page 16). In case the page does not load, check the proxy settings of your browser. When the CER controller is on the local network or connected directly with a cross cable, no proxy server should be used for its IP address.

The ping test · ping · The browser test

Page 23 of the Field Controls Draft Regulator (10) user manual — TELEPHONE
Page 23 · click to enlarge
Page 23

Serial interface

In this part of the installation manual, you will learn some basics of serial communication, the hardware involved and how the CER controller connects to your RS- 232 device.

RS-232

The RS-232 standard (RS stands for recommended standards) was published first in 1969 by the EIA (Electronic Industries Association). It was originally drawn up to specify the connections between terminals and modems. It specifies the electrical characteristics of circuits between the devices and gives names and numbers to the wires.

RS-232-C is the third - and most common - version of the standard so it is often simply referred to as RS-232 (without the 'c'). The combination of ITU-T's (formerly CCITT) V.24 and V.28 standards are equivalent to EIA-RS-232-C. In short: V.24+V.28 RS-232.

The characteristics of the RS-232c protocol are as follows: S point-to-point communication (full duplex) S maximum line length between sender and receiver 15 meters (50 feet).

In serial communication, you'll encounter many references to the rather cryptic terms DTE (Data Terminal Equipment) and DCE (Data Communication Equipment). The word terminal indicates the end of the line, as in bus terminal. In the phrase data terminal equipment it means the extreme ends of the data communications circuit. The data communications equipment, modems for example, provide the communication between the two DTEs.

TELEPHONE

NETWORK

DCE

DCE

DTE

DTE

The 9-pin RS-232c connector is described in the EIA/TIA-574 standard. See the chapter “Pin Assignments” for Hardware platform specific information about the pin-out.

Show 8 more labels / short text on this page
Serial interfaces · The RS-232c standard · The connections · Computer · Terminal · Modem Modem · RS-232c RS-232c · The RS-232c pin-out
Page 24 of the Field Controls Draft Regulator (10) user manual — RS-485 (option only)
Page 24 · click to enlarge
Page 24

RS-485 (option only)

The RS-485 communication protocol is the industry's most widely used bidirectional, balanced transmission line standard. It is specifically designed for industrial multi-drop systems that should be able to transmit and receive data at high rates or over long distances.

RS-485 (RS stands for recommended standards) is accepted as a standard in 1983 by the EIA (Electronic Industries Association). The full name of the latest revision is TIA/EIA RS- 485-A, published March 3, 1998 which is equivalent to the ISO 8482 standard.

The characteristics of the RS-485 protocol are as follows: S bi-directional master-slave communication over a single twisted-pair (half-duplex) S up to 32 nodes per segment S maximum line length per segment of 1200 meters (4000 feet).

By using repeaters, multiple networks (segments) can be chained together to accommodate virtually an unlimited number of nodes.

As with the implementation of many standards, there is a difference between theory and practice. Though the RS-485 standard mentions a maximum of 32 nodes and a line lenght of 1200 meters, in practice it depends on the used transceivers, cable quality and network topology. For a deeper understanding of RS-485 in real-world applications, check the list of recommended literature at the end of this manual.

RS-485 is not difficult, though some care has to be taken when adding a controller as a new device on the bus. This chapter explains some of the basic terms and wiring strategy though it does not intend to go into to much detail.

To learn more about the practical use of RS-485 please refer to many excellent resources on this subject. Find a list of recommended literature at the end of this installation manual.

RS-485 is used for multi-point communications: more devices may be connected to a single signal cable. Most RS-485 systems use the Master/Slave architecture, where each slave unit has its unique address and responds only to packets addressed to this unit. These packets are generated by the master (e.g. PC), which periodically polls all connected slave units. In Master/Slave systems, slaves never start the communications.

In Multi-Master systems, each node can initiate its own transmission creating the potential for data collisions. This type of system requires a more sophisticated method of error detection, including methods such as line contention detection, acknowledgment of transmission and a system for resending corrupted data. This is not specified in the RS-485 standard.

The RS-485 standard · The connections · Masters and Slaves

Page 25 of the Field Controls Draft Regulator (10) user manual — RS-485 (option only)
Page 25 · click to enlarge
Page 25

Network topology and wiring

Multi-drop RS-485 implies that there are two main wires in a segment labeled DATA+ and DATA– or simple A and B. The wiring comes as a twisted pair. To reduce electrical noise, it should be twisted as tightly as possible. It is advisable to follow the standard colors used for the communication lines: Yellow for DATA+ (A), Green for DATA– (B).

For safe operation, a signal ground line should also be connected in the system. All connected devices tap from these two lines with so called drop cables. The connections are parallel so connecting or disconnecting of a node does not affect the network as a whole.

The network configuration isn't defined in the RS-485 specification. The designer can use a configuration that best fits the physical requirements of the system. In existing systems one should obey the rules of that network, of course.

A: Backbone with stubs (workable) C: Star network (avoid)

D: Mixed, backbone & star (avoid) B: Daisy chain (best)

If the traffic on the network is slow and the cable lengths are short, topology is not an issue. But as soon as transmission speeds are higher or distances longer, you should be aware of the physical network layout. The daisy chain configuration is the best choice. The backbone and star networks are not impossible but it is hard to control reflections and harmful transmission-line effects.

Termination resistors are used to match impedance of a node to the impedance of the transmission line being used. When impedances are mismatched, the transmitted signal is not completely absorbed by the load and a portion is reflected back into the transmission line. If the source, transmission line and load impedances are equal, these reflections are eliminated.

Commonly used RS-485 cabling, such as Category 5 (CAT5) cable, has an impedance of 100 Ohm. When cables run longer than about 10 meters, termination resistors of 100 Ohm should be installed at the both ends of the cable.

Serial interfaces · Line termination

Page 26 of the Field Controls Draft Regulator (10) user manual — RS-485 (option only)
Page 26 · click to enlarge
Page 26

Automatic Data Flow Control Function for RS-485

The CER controller automatically senses the direction of incoming data and switches its transmission direction accordingly. Therefore no handshaking signal (e.g. RTS signal) is necessary. This feature lets you simply and quickly build an RS-485 network with just two wires. More importantly, application software previously written for half duplex RS-232 environments can be maintained without need for modification.

See the chapter “Pin Assignments” for Hardware platform specific information about the pin-out.

The RS-485 pin-out

Page 27 of the Field Controls Draft Regulator (10) user manual — Ports on your controller
Page 27 · click to enlarge
Page 27

Ports on your controller

Hardware Platform 10 has different versions, depending on the model you choose:

Field Controls Draft Regulator (10) — Ports on your controller diagram (page 27)
Fig. 15 · Ports on your controller

Model USB* Port 1** Port 2 Port 3 Port 4

* Available as option. ** No handshake signals are available on port 1 (When available, Port 2, 3 and 4 are equipped with full handshake signals)

Serial interfaces

Page 28 of the Field Controls Draft Regulator (10) user manual — - +
Page 28 · click to enlarge
Page 28

Pin Assignments

RS-232 and RS-485 Serial Ports

Field Controls Draft Regulator (10) — Pin Assignments diagram (page 28)
Fig. 16 · Pin Assignments

Port 1 Port 2/3 (Option only) Port 2 (Option only)

- +

Pin diameter2.1mm Outer diameter: 5.5mm

inner +7-18 V DC

Power Connector · Pin Signal Name · outer GND

Page 29 of the Field Controls Draft Regulator (10) user manual — 1 +5V DC
Page 29 · click to enlarge
Page 29
Field Controls Draft Regulator (10) — 1 +5V DC diagram (page 29)
Fig. 17
Field Controls Draft Regulator (10) — 1 +5V DC diagram (page 29)
Fig. 18
Field Controls Draft Regulator (10) — 1 +5V DC diagram (page 29)
Fig. 19

1 +5V DC

2 D –

3 D +

4 GND

Show 4 more labels / short text on this page
Pin Assignments · Ethernet · USB Ports · Pin Signal
Page 30 of the Field Controls Draft Regulator (10) user manual — 2 GND 2 GND
Page 30 · click to enlarge
Page 30

VGA

Field Controls Draft Regulator (10) — VGA diagram (page 30)
Fig. 20

Audio In & Out

Pin Signal Pin Signal

1 Audio line In 1 Audio line Out

2 GND 2 GND

Page 31 of the Field Controls Draft Regulator (10) user manual — Technical Specifications
Page 31 · click to enlarge
Page 31

Technical Specifications

CPU (type A) 433MHz AMD Geode LX700

(type B/C) 500MHz AMD Geode LX800

Memory (type A) 128 MB SDRAM

(type B/C) 256 MB SDRAM

Storage (type A/B) 1GB GB Flash drive (256MB reserved for system)

(type C) 4GB GB Flash drive (256MB reserved for system)

Power supply voltage 7-18V DC on power adapter plug

Power consumption 0.25-0.4A max at 12V DC (excl. USB devices)

Operating temperature 0 ~ 50°C (32 ~ 122°F)

Indoor:

Mechanical Aluminum casing, desktop use or DIN-rail mount

16.3 x 11.25 x 3.0 cm (6.42 x 4.43 x 1.18 inch)

Outdoor version:

Die-Cast Aluminium NEMA-67 casing, wall or 1" mast mount

21 x 15 x 6 cm (8.3 x 5.9 x 2.4 inch) without bracket

Interface one RS-232 serial port (EIA/TIA-232-C)

Connector D-sub 9 pins (EIA/TIA-574)

Distance 15.2 meter max (50 feet)

Data bits 5, 6, 7 or 8

Stop bits 1, 1½ or 2

Parity Even, Odd, Mark, Space, None

Flow control (Port 1) XON/XOFF, None

(Port 2/3 Optional) XON/XOFF, CTS/RTS, DTR/DSR, None

Signals (Port 1) TxD, RxD, GND

(Port 2/3 Optional) TxD, RxD, RTS, CTS, DSR, DTR, CD, RI, GND

Show 8 more labels / short text on this page
Technical Specifications · Hardware · Indicators Power LED · Case · Dimensions (WxDxH) · Mechanical · Dimension (WxDxH) · RS-232 Interface
Page 32 of the Field Controls Draft Regulator (10) user manual — Technical Specifications
Page 32 · click to enlarge
Page 32

RS-485 Interface (option only)

Interface one RS-485 serial port (EIA/TIA-485-A, ISO 8482)

Connector D-sub 9 pins

Distance 1220 meter max (4000 feet)

Data bits 5, 6, 7 or 8

Stop bits 1, 1½ or 2

Parity Even, Odd, Mark, Space, None

Signals DATA+ (A), DATA– (B), GND

Indicators Link and status LEDs

Extra Power over Ethernet

USB Interface (option only)

Interface two USB serial ports, Rev 2.0 compliant

Connector USB type A

Video Interface (model C only)

Connector VGA 15 pin

Audio Interface (model C only)

Interface Audio-InAudio-Out:
Show 6 more labels / short text on this page
Flow control Automatic · Network Interface · Interface 10/100Base-T ethernet · Connector RJ-45 · Interface VGA · Connector jack 3,5mm
Page 33 of the Field Controls Draft Regulator (10) user manual — Physical Dimensions
Page 33 · click to enlarge
Page 33

Physical Dimensions

Field Controls Draft Regulator (10) — Physical Dimensions diagram (page 33)
Fig. 21 · Physical Dimensions

All sizes in millimeters

Physical Dimensions

Page 34 of the Field Controls Draft Regulator (10) user manual — Regulatory
Page 34 · click to enlarge
Page 34

Notice to the user

Regulatory

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

WARNING: Properly shielded and grounded cables and connectors must be used in order to meet FCC emission limits. Neither the provider nor the manufacturer are responsible for any radio or television interference caused by using other than recommended cables and connectors or by unauthorized changes or modifications to this equipment. Changes or modifications made to this device which are not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.

This product has been tested and found to comply with the limits for Class A Information Technology Equipment according to CISPR 22/European Standard EN 55022. The limits for Class A equipment were derived for commercial and industrial environments to provide reasonable protection against interference with licensed communication equipment.

This Class A digital apparatus complies with Canadian ICES-003.

This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications.

Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada.

Le présent appareil numérique n'émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la classe A prescrites dans le Règlement sur le brouillage radioélectrique édicté par le ministère des Communications du Canada.

FCC Notice · CE Notice · Industry Canada Notice

Page 35 of the Field Controls Draft Regulator (10) user manual — Copyrights
Page 35 · click to enlarge
Page 35

Declaration of Confority

Declaration of Conformity according to ISO Guide 22 and EN 45014

Manufacturer's nameCER International bv Manufacturer's address: Postbus 258 4700 AG Roosendaal The Netherlands

declares that the product:

Product NameFieldCommander Model Number: ELS1700/ELS1722/EWS1700/EWS1722/ FC2700/FC3700/FC3733/FC3724 Product Options: all

conforms to the following Product Specifications:

EMC Directive89/336/EEC for CE Marking

EN 55022: 1998 (Class A) EN 61000-3-2: 2000 EN 61000-3-3: 1995 EN 55024: 1998 (IEC 61000-4-2:1995, IEC 61000-4-3:1995, IEC 61000-4-4:1995, IEC 61000-4-5:1995, IEC 61000-4-6:1996, IEC 61000-4-8:1993, IEC 61000-4-11:1994)

Supplemental Information: The product herewith complies with the requirements of the EMC Directive 89/336/EEC and carries the -marking accordingly.

Field Controls Draft Regulator (10) — Declaration of Confority diagram (page 35)
Fig. 22 · Declaration of Confority

A. van den Broek General Manager

Trademarks

CER and FieldCommander are registered trademarks of CER International bv.

All other product names and services identified throughout this book are trademarks or registered trademarks of their respective companies. They are used throughout this manual in editorial fashion only and for the benefit of such companies. No such uses, or the use of any trade name, is intended to convey endorsement or other affiliation with this manual.

Copyrights

Copyright © 2008 CER International bv. All rights reserved.

No part of this publication may be reproduced in any form, or stored in a database or retrieval system, or transmitted or distributed in any form by any means, electronic, mechanical photocopying, recording, or otherwise, without the prior written permission of CER International bv, except as permitted by the Copyright Act of 1976 and except that program listings may be entered, stored and executed in a computer system.

THE INFORMATION AND MATERIAL CONTAINED IN THIS MANUAL ARE PROVIDED "AS IS," WITHOUT WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION ANY WARRANTY CONCERNING THE ACCURACY, ADEQUACY, OR COMPLETENESS OF SUCH INFORMATION OR MATERIAL OR THE RESULT TO BE OBTAINED FROM USING SUCH INFORMATION OR MATERIAL, NEITHER CER INTERNATIONAL BV NOR THE AUTHORS SHALL BE RESPONSIBLE FOR ANY CLAIMS ATTRIBUTABLE TO ERRORS, OMISSIONS, OR OTHER INACCURACIES IN THE INFORMATION OR MATERIAL CONTAINED IN THIS MANUAL, AND IN NO EVENT SHALL CER INTERNATIONAL BV OR THE AUTHORS BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE OF SUCH INFORMATION OR MATERIAL.

Page 36 of the Field Controls Draft Regulator (10) user manual — Declaration of Confority
Page 36 · click to enlarge
Page 36
Field Controls Draft Regulator (10) — Declaration of Confority diagram (page 36)
Fig. 23 · Declaration of Confority

The latest documentation is available

from http://www.cer.com

FieldCommander is a product of:

Postbus 258 NL 4700 AG Roosendaal

The Netherlands TEL+31 (0)165 557417 FAX: +31 (0)165 562151

http://www.cer.com

Part no. FCHWP10IG, revision 3.5.34

Ask about the Field Controls Draft Regulator (10)

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Field Controls Draft Regulator (10)

Be the first to ask — other owners or our team will answer.

Original document

Field Controls Draft Regulator (10) manual PDF

36 pages·942 KB·Network Router·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…