System Overviewp.131.1. Product Descriptionp.131.2. Front Panel Indicators and Controlsp.141.3. Terminal Block Designationsp.151.4. Rear Panel Indicatorsp.181.5. SW1 Switch Settingsp.18Getting Startedp.192.1. Installationp.192.2. Communicationp.192.3. Set the F3400/F1000’s IP Addressp.192.3.1 Set the F3400/F1000's IP Address using the ARP and PING Commandsp.202.3.1.1 Obtain the Ethernet Addressp.202.3.1.2 Use the ARP Commandp.202.3.1.3 Use the PING Commandp.202.3.1.4 Troubleshooting the ARP/PING Commandsp.212.3.2 Set the F3400/F1000’s IP Address using a Web Browserp.212.3.3 Set the F3400/F1000’s IP Address Using an EIA232 Connectionp.222.3.4 Set the F3400/F1000's IP Address using a Telnet Connectionp.222.4. F3400/F1000 Wiringp.232.4.1 Power Supply and Ground Connectionsp.232.4.2 EIA232 COM1 Connectionp.242.4.3 RJ11 Phone Line Connectionp.242.4.4 RJ45 Ethernet Connectionp.252.4.5 Relay K1 and K2 Connectionp.26F3400/F1000 Web Interfacep.273.1. F3400/F1000 Web Interface Overviewp.273.2. Main Menup.273.2.1 Historical Datap.283.2.1.1 Alarm Historyp.283.2.1.2 Event Historyp.293.2.1.3 Digital Status Historyp.303.2.1.4 Web User Access Logp.303.2.1.5 Data Historyp.313.2.1.6 Minute, Hour, and Day Viewp.313.2.1.7 Data History Text Downloadsp.323.2.1.8 Server Historyp.323.2.1.9 Server Statusp.333.3. Identityp.333.4. Web Linksp.343.5. Configurationp.34Configuration Menup.354.1. Inputsp.364.2. Relaysp.404.3. Schedulesp.414.4. Alarm Managementp.424.5. Modemp.434.5.1 Configure Phone Numbersp.444.6. Web Linksp.464.7. Egg/Nestp.474.8. Falcon Linksp.474.9. SNMP/SYSLOGp.484.10. Modbus Interfacep.494.10.1 LD Unit Modbus Slave Configurationp.504.10.2 Modbus Register Data Logp.514.10.3 Modbus Packet Logp.514.10.4 Reset Modbus Portp.524.10.5 F-Series Modbus Slave Register Mapp.524.11. BACnetp.534.12. Server Pingp.544.13. Systemp.554.14. Clockp.564.15. Internet Protocolp.564.16. User Administration (Web Access)p.574.17. Emailp.584.18. Network Time Protocolp.594.19. Network Statisticsp.604.20. Flash Programp.604.21. Product Registrationp.61EIA-232 Interfacep.635.1. Unit Start Upp.645.2. Flash Executable Codep.645.3. Main Menup.655.3.1 Main Configuration Menu – SCp.665.3.2 IP Configuration Menup.67Remote Accessp.696.1. Remote Access Configuration (Modem Option)p.69Point-to-Point Protocolp.717.1. Configuring the F3400/F1000p.717.2. Configuring the PCp.72Upgrading Firmware and Managing Configuration Datap.738.1. Upgrading F3400/F1000 Firmwarep.738.1.1 Upgrading F3400/F1000 Firmware via TFTP Clientp.748.1.2 Updating F3400/F1000 Firmware via the EIA232 COM1 Port (X-Modem)p.758.2. Loading/Saving F3400/F1000 Configuration Datap.768.2.1 Saving Configuration Data via TFTP Clientp.768.2.2 Saving Configuration Data via EIA232 COM1 Port (XModem)p.768.2.3 Loading Configuration Data via TFTP Clientp.778.2.4 Loading Configuration Data via EIA232 COM1 Port (X-Modem)p.77Analog Input 4-20mA Reference Chartp.79F3400/F1000 Accessories Wiringp.81B.1. Configuring the SeaHawk LD5100 as an Analog Inputp.84Alarm ID Reference Tablesp.87C.1. Analog Tablesp.87C.2. Thermistor Tablesp.88C.3. Digital Tablesp.89Technical Specificationsp.91
Page 1 of the Falcon Digital Video Recorder (F1000) user manual — Monitoring & Notification
Page 1 · click to enlarge
Page 1

Monitoring & Notification

F3400/F1000 (F-Series) User Guide

Falcon Digital Video Recorder (F1000) — Monitoring & Notification diagram (page 1)
Fig. 1 · Monitoring & Notification
Page 2 of the Falcon Digital Video Recorder (F1000) user manual — Revision History
Page 2 · click to enlarge
Page 2

Copyright Notice

©2010 RLE Technologies. All rights reserved. No part of this publication may be reproduced or distributed in any form or by any means, or stored in a database or retrieval system, without the prior written permission of RLE Technologies.

Trademark Notices

RLE is a registered trademark and Falcon, Raptor, and SeaHawk are trademarks of RLE Technologies. All other trademarks or registered trademarks are the property of their respective companies.

Revision History

Rev. No.Date 3.0June 2010

rletech.com 2 970.484.6510

Part number 11049

Page 3 of the Falcon Digital Video Recorder (F1000) user manual — Technical Support
Page 3 · click to enlarge
Page 3

Product Registration

  • Product registration helps RLE Technologies inform owners of:
  • Product upgrades
  • Firmware enhancements
  • New products and technologies
  • Special offers available only to registered users

Access and submit Product Registration information from the F1000/F3400 Configuration Menu.

Any information provided to RLE Technologies through the registration form will be regarded as confidential. RLE will not sell or distribute any of the information to third parties. To read our Privacy Policy, please visit our website: www.rletech.com

Technical Support

Personal assistance is available Monday through Friday, from 8:00 a.m. to 5:00 p.m. MST.

A request for assistance may be sent to support@rletech.com.

Otherwise, please call us directly at: (970) 484-6510, and press “2” for technical support.

The following information is located on the bottom of each F1000/F3400 unit.Please have this information available whenever a technical support call is placed:

970.484.6510 3 rletech.com

Product Model Number · Product Serial Number · Product Manufacture Date

Page 4 of the Falcon Digital Video Recorder (F1000) user manual — Notes:
Page 4 · click to enlarge
Page 4

Notes:

rletech.com 4 970.484.6510

Page 5 of the Falcon Digital Video Recorder (F1000) user manual — Table of contents
Page 5 · click to enlarge
Page 5

Table of contents

System Overviewp.131.1. Product Descriptionp.131.2. Front Panel Indicators and Controlsp.141.3. Terminal Block Designationsp.151.4. Rear Panel Indicatorsp.181.5. SW1 Switch Settingsp.18Getting Startedp.192.1. Installationp.192.2. Communicationp.192.3. Set the F3400/F1000’s IP Addressp.192.3.1 Set the F3400/F1000's IP Address using the ARP and PING Commandsp.202.3.1.1 Obtain the Ethernet Addressp.202.3.1.2 Use the ARP Commandp.202.3.1.3 Use the PING Commandp.202.3.1.4 Troubleshooting the ARP/PING Commandsp.212.3.2 Set the F3400/F1000’s IP Address using a Web Browserp.212.3.3 Set the F3400/F1000’s IP Address Using an EIA232 Connectionp.222.3.4 Set the F3400/F1000's IP Address using a Telnet Connectionp.222.4. F3400/F1000 Wiringp.232.4.1 Power Supply and Ground Connectionsp.232.4.2 EIA232 COM1 Connectionp.242.4.3 RJ11 Phone Line Connectionp.242.4.4 RJ45 Ethernet Connectionp.252.4.5 Relay K1 and K2 Connectionp.26F3400/F1000 Web Interfacep.273.1. F3400/F1000 Web Interface Overviewp.273.2. Main Menup.273.2.1 Historical Datap.283.2.1.1 Alarm Historyp.283.2.1.2 Event Historyp.293.2.1.3 Digital Status Historyp.303.2.1.4 Web User Access Logp.303.2.1.5 Data Historyp.313.2.1.6 Minute, Hour, and Day Viewp.313.2.1.7 Data History Text Downloadsp.323.2.1.8 Server Historyp.323.2.1.9 Server Statusp.333.3. Identityp.333.4. Web Linksp.343.5. Configurationp.34Configuration Menup.354.1. Inputsp.364.2. Relaysp.404.3. Schedulesp.414.4. Alarm Managementp.424.5. Modemp.434.5.1 Configure Phone Numbersp.444.6. Web Linksp.464.7. Egg/Nestp.474.8. Falcon Linksp.474.9. SNMP/SYSLOGp.484.10. Modbus Interfacep.494.10.1 LD Unit Modbus Slave Configurationp.504.10.2 Modbus Register Data Logp.514.10.3 Modbus Packet Logp.514.10.4 Reset Modbus Portp.524.10.5 F-Series Modbus Slave Register Mapp.524.11. BACnetp.534.12. Server Pingp.544.13. Systemp.554.14. Clockp.564.15. Internet Protocolp.564.16. User Administration (Web Access)p.574.17. Emailp.584.18. Network Time Protocolp.594.19. Network Statisticsp.604.20. Flash Programp.604.21. Product Registrationp.61EIA-232 Interfacep.635.1. Unit Start Upp.645.2. Flash Executable Codep.645.3. Main Menup.655.3.1 Main Configuration Menu – SCp.665.3.2 IP Configuration Menup.67Remote Accessp.696.1. Remote Access Configuration (Modem Option)p.69Point-to-Point Protocolp.717.1. Configuring the F3400/F1000p.717.2. Configuring the PCp.72Upgrading Firmware and Managing Configuration Datap.738.1. Upgrading F3400/F1000 Firmwarep.738.1.1 Upgrading F3400/F1000 Firmware via TFTP Clientp.748.1.2 Updating F3400/F1000 Firmware via the EIA232 COM1 Port (X-Modem)p.758.2. Loading/Saving F3400/F1000 Configuration Datap.768.2.1 Saving Configuration Data via TFTP Clientp.768.2.2 Saving Configuration Data via EIA232 COM1 Port (XModem)p.768.2.3 Loading Configuration Data via TFTP Clientp.778.2.4 Loading Configuration Data via EIA232 COM1 Port (X-Modem)p.77Analog Input 4-20mA Reference Chartp.79F3400/F1000 Accessories Wiringp.81B.1. Configuring the SeaHawk LD5100 as an Analog Inputp.84Alarm ID Reference Tablesp.87C.1. Analog Tablesp.87C.2. Thermistor Tablesp.88C.3. Digital Tablesp.89Technical Specificationsp.91
Page 6 of the Falcon Digital Video Recorder (F1000) user manual — Table of contents
Page 6 · click to enlarge
Page 6

Table of contents

System Overviewp.131.1. Product Descriptionp.131.2. Front Panel Indicators and Controlsp.141.3. Terminal Block Designationsp.151.4. Rear Panel Indicatorsp.181.5. SW1 Switch Settingsp.18Getting Startedp.192.1. Installationp.192.2. Communicationp.192.3. Set the F3400/F1000’s IP Addressp.192.3.1 Set the F3400/F1000's IP Address using the ARP and PING Commandsp.202.3.1.1 Obtain the Ethernet Addressp.202.3.1.2 Use the ARP Commandp.202.3.1.3 Use the PING Commandp.202.3.1.4 Troubleshooting the ARP/PING Commandsp.212.3.2 Set the F3400/F1000’s IP Address using a Web Browserp.212.3.3 Set the F3400/F1000’s IP Address Using an EIA232 Connectionp.222.3.4 Set the F3400/F1000's IP Address using a Telnet Connectionp.222.4. F3400/F1000 Wiringp.232.4.1 Power Supply and Ground Connectionsp.232.4.2 EIA232 COM1 Connectionp.242.4.3 RJ11 Phone Line Connectionp.242.4.4 RJ45 Ethernet Connectionp.252.4.5 Relay K1 and K2 Connectionp.26F3400/F1000 Web Interfacep.273.1. F3400/F1000 Web Interface Overviewp.273.2. Main Menup.273.2.1 Historical Datap.283.2.1.1 Alarm Historyp.283.2.1.2 Event Historyp.293.2.1.3 Digital Status Historyp.303.2.1.4 Web User Access Logp.303.2.1.5 Data Historyp.313.2.1.6 Minute, Hour, and Day Viewp.313.2.1.7 Data History Text Downloadsp.323.2.1.8 Server Historyp.323.2.1.9 Server Statusp.333.3. Identityp.333.4. Web Linksp.343.5. Configurationp.34Configuration Menup.354.1. Inputsp.364.2. Relaysp.404.3. Schedulesp.414.4. Alarm Managementp.424.5. Modemp.434.5.1 Configure Phone Numbersp.444.6. Web Linksp.464.7. Egg/Nestp.474.8. Falcon Linksp.474.9. SNMP/SYSLOGp.484.10. Modbus Interfacep.494.10.1 LD Unit Modbus Slave Configurationp.504.10.2 Modbus Register Data Logp.514.10.3 Modbus Packet Logp.514.10.4 Reset Modbus Portp.524.10.5 F-Series Modbus Slave Register Mapp.524.11. BACnetp.534.12. Server Pingp.544.13. Systemp.554.14. Clockp.564.15. Internet Protocolp.564.16. User Administration (Web Access)p.574.17. Emailp.584.18. Network Time Protocolp.594.19. Network Statisticsp.604.20. Flash Programp.604.21. Product Registrationp.61EIA-232 Interfacep.635.1. Unit Start Upp.645.2. Flash Executable Codep.645.3. Main Menup.655.3.1 Main Configuration Menu – SCp.665.3.2 IP Configuration Menup.67Remote Accessp.696.1. Remote Access Configuration (Modem Option)p.69Point-to-Point Protocolp.717.1. Configuring the F3400/F1000p.717.2. Configuring the PCp.72Upgrading Firmware and Managing Configuration Datap.738.1. Upgrading F3400/F1000 Firmwarep.738.1.1 Upgrading F3400/F1000 Firmware via TFTP Clientp.748.1.2 Updating F3400/F1000 Firmware via the EIA232 COM1 Port (X-Modem)p.758.2. Loading/Saving F3400/F1000 Configuration Datap.768.2.1 Saving Configuration Data via TFTP Clientp.768.2.2 Saving Configuration Data via EIA232 COM1 Port (XModem)p.768.2.3 Loading Configuration Data via TFTP Clientp.778.2.4 Loading Configuration Data via EIA232 COM1 Port (X-Modem)p.77Analog Input 4-20mA Reference Chartp.79F3400/F1000 Accessories Wiringp.81B.1. Configuring the SeaHawk LD5100 as an Analog Inputp.84Alarm ID Reference Tablesp.87C.1. Analog Tablesp.87C.2. Thermistor Tablesp.88C.3. Digital Tablesp.89Technical Specificationsp.91
Page 7 of the Falcon Digital Video Recorder (F1000) user manual
Page 7 · click to enlarge
Page 7

A Analog Input 4-20mA Reference Chart 79

B F3400/F1000 Accessories Wiring 81

Configuring the SeaHawk LD5100 as an Analog Input 84

C Alarm ID Reference Tables 87

Analog Tables 87 Thermistor Tables 88 Digital Tables 89

D Technical Specifications 91

970.484.6510 7 rletech.com

Page 8 of the Falcon Digital Video Recorder (F1000) user manual — Notes:
Page 8 · click to enlarge
Page 8

Notes:

970.484.6510 8 rletech.com

Page 9 of the Falcon Digital Video Recorder (F1000) user manual — Table of contents
Page 9 · click to enlarge
Page 9

Table of contents

System Overviewp.131.1. Product Descriptionp.131.2. Front Panel Indicators and Controlsp.141.3. Terminal Block Designationsp.151.4. Rear Panel Indicatorsp.181.5. SW1 Switch Settingsp.18Getting Startedp.192.1. Installationp.192.2. Communicationp.192.3. Set the F3400/F1000’s IP Addressp.192.3.1 Set the F3400/F1000's IP Address using the ARP and PING Commandsp.202.3.1.1 Obtain the Ethernet Addressp.202.3.1.2 Use the ARP Commandp.202.3.1.3 Use the PING Commandp.202.3.1.4 Troubleshooting the ARP/PING Commandsp.212.3.2 Set the F3400/F1000’s IP Address using a Web Browserp.212.3.3 Set the F3400/F1000’s IP Address Using an EIA232 Connectionp.222.3.4 Set the F3400/F1000's IP Address using a Telnet Connectionp.222.4. F3400/F1000 Wiringp.232.4.1 Power Supply and Ground Connectionsp.232.4.2 EIA232 COM1 Connectionp.242.4.3 RJ11 Phone Line Connectionp.242.4.4 RJ45 Ethernet Connectionp.252.4.5 Relay K1 and K2 Connectionp.26F3400/F1000 Web Interfacep.273.1. F3400/F1000 Web Interface Overviewp.273.2. Main Menup.273.2.1 Historical Datap.283.2.1.1 Alarm Historyp.283.2.1.2 Event Historyp.293.2.1.3 Digital Status Historyp.303.2.1.4 Web User Access Logp.303.2.1.5 Data Historyp.313.2.1.6 Minute, Hour, and Day Viewp.313.2.1.7 Data History Text Downloadsp.323.2.1.8 Server Historyp.323.2.1.9 Server Statusp.333.3. Identityp.333.4. Web Linksp.343.5. Configurationp.34Configuration Menup.354.1. Inputsp.364.2. Relaysp.404.3. Schedulesp.414.4. Alarm Managementp.424.5. Modemp.434.5.1 Configure Phone Numbersp.444.6. Web Linksp.464.7. Egg/Nestp.474.8. Falcon Linksp.474.9. SNMP/SYSLOGp.484.10. Modbus Interfacep.494.10.1 LD Unit Modbus Slave Configurationp.504.10.2 Modbus Register Data Logp.514.10.3 Modbus Packet Logp.514.10.4 Reset Modbus Portp.524.10.5 F-Series Modbus Slave Register Mapp.524.11. BACnetp.534.12. Server Pingp.544.13. Systemp.554.14. Clockp.564.15. Internet Protocolp.564.16. User Administration (Web Access)p.574.17. Emailp.584.18. Network Time Protocolp.594.19. Network Statisticsp.604.20. Flash Programp.604.21. Product Registrationp.61EIA-232 Interfacep.635.1. Unit Start Upp.645.2. Flash Executable Codep.645.3. Main Menup.655.3.1 Main Configuration Menu – SCp.665.3.2 IP Configuration Menup.67Remote Accessp.696.1. Remote Access Configuration (Modem Option)p.69Point-to-Point Protocolp.717.1. Configuring the F3400/F1000p.717.2. Configuring the PCp.72Upgrading Firmware and Managing Configuration Datap.738.1. Upgrading F3400/F1000 Firmwarep.738.1.1 Upgrading F3400/F1000 Firmware via TFTP Clientp.748.1.2 Updating F3400/F1000 Firmware via the EIA232 COM1 Port (X-Modem)p.758.2. Loading/Saving F3400/F1000 Configuration Datap.768.2.1 Saving Configuration Data via TFTP Clientp.768.2.2 Saving Configuration Data via EIA232 COM1 Port (XModem)p.768.2.3 Loading Configuration Data via TFTP Clientp.778.2.4 Loading Configuration Data via EIA232 COM1 Port (X-Modem)p.77Analog Input 4-20mA Reference Chartp.79F3400/F1000 Accessories Wiringp.81B.1. Configuring the SeaHawk LD5100 as an Analog Inputp.84Alarm ID Reference Tablesp.87C.1. Analog Tablesp.87C.2. Thermistor Tablesp.88C.3. Digital Tablesp.89Technical Specificationsp.91
Page 10 of the Falcon Digital Video Recorder (F1000) user manual — Table of contents
Page 10 · click to enlarge
Page 10

Table of contents

System Overviewp.131.1. Product Descriptionp.131.2. Front Panel Indicators and Controlsp.141.3. Terminal Block Designationsp.151.4. Rear Panel Indicatorsp.181.5. SW1 Switch Settingsp.18Getting Startedp.192.1. Installationp.192.2. Communicationp.192.3. Set the F3400/F1000’s IP Addressp.192.3.1 Set the F3400/F1000's IP Address using the ARP and PING Commandsp.202.3.1.1 Obtain the Ethernet Addressp.202.3.1.2 Use the ARP Commandp.202.3.1.3 Use the PING Commandp.202.3.1.4 Troubleshooting the ARP/PING Commandsp.212.3.2 Set the F3400/F1000’s IP Address using a Web Browserp.212.3.3 Set the F3400/F1000’s IP Address Using an EIA232 Connectionp.222.3.4 Set the F3400/F1000's IP Address using a Telnet Connectionp.222.4. F3400/F1000 Wiringp.232.4.1 Power Supply and Ground Connectionsp.232.4.2 EIA232 COM1 Connectionp.242.4.3 RJ11 Phone Line Connectionp.242.4.4 RJ45 Ethernet Connectionp.252.4.5 Relay K1 and K2 Connectionp.26F3400/F1000 Web Interfacep.273.1. F3400/F1000 Web Interface Overviewp.273.2. Main Menup.273.2.1 Historical Datap.283.2.1.1 Alarm Historyp.283.2.1.2 Event Historyp.293.2.1.3 Digital Status Historyp.303.2.1.4 Web User Access Logp.303.2.1.5 Data Historyp.313.2.1.6 Minute, Hour, and Day Viewp.313.2.1.7 Data History Text Downloadsp.323.2.1.8 Server Historyp.323.2.1.9 Server Statusp.333.3. Identityp.333.4. Web Linksp.343.5. Configurationp.34Configuration Menup.354.1. Inputsp.364.2. Relaysp.404.3. Schedulesp.414.4. Alarm Managementp.424.5. Modemp.434.5.1 Configure Phone Numbersp.444.6. Web Linksp.464.7. Egg/Nestp.474.8. Falcon Linksp.474.9. SNMP/SYSLOGp.484.10. Modbus Interfacep.494.10.1 LD Unit Modbus Slave Configurationp.504.10.2 Modbus Register Data Logp.514.10.3 Modbus Packet Logp.514.10.4 Reset Modbus Portp.524.10.5 F-Series Modbus Slave Register Mapp.524.11. BACnetp.534.12. Server Pingp.544.13. Systemp.554.14. Clockp.564.15. Internet Protocolp.564.16. User Administration (Web Access)p.574.17. Emailp.584.18. Network Time Protocolp.594.19. Network Statisticsp.604.20. Flash Programp.604.21. Product Registrationp.61EIA-232 Interfacep.635.1. Unit Start Upp.645.2. Flash Executable Codep.645.3. Main Menup.655.3.1 Main Configuration Menu – SCp.665.3.2 IP Configuration Menup.67Remote Accessp.696.1. Remote Access Configuration (Modem Option)p.69Point-to-Point Protocolp.717.1. Configuring the F3400/F1000p.717.2. Configuring the PCp.72Upgrading Firmware and Managing Configuration Datap.738.1. Upgrading F3400/F1000 Firmwarep.738.1.1 Upgrading F3400/F1000 Firmware via TFTP Clientp.748.1.2 Updating F3400/F1000 Firmware via the EIA232 COM1 Port (X-Modem)p.758.2. Loading/Saving F3400/F1000 Configuration Datap.768.2.1 Saving Configuration Data via TFTP Clientp.768.2.2 Saving Configuration Data via EIA232 COM1 Port (XModem)p.768.2.3 Loading Configuration Data via TFTP Clientp.778.2.4 Loading Configuration Data via EIA232 COM1 Port (X-Modem)p.77Analog Input 4-20mA Reference Chartp.79F3400/F1000 Accessories Wiringp.81B.1. Configuring the SeaHawk LD5100 as an Analog Inputp.84Alarm ID Reference Tablesp.87C.1. Analog Tablesp.87C.2. Thermistor Tablesp.88C.3. Digital Tablesp.89Technical Specificationsp.91
Page 11 of the Falcon Digital Video Recorder (F1000) user manual — Tables
Page 11 · click to enlarge
Page 11

Tables

1 System Overview 13 Table 1.1 Terminal Block Designations 15 Table 1.2 Rear Panel Status Indicators 18

4 Configuration Menu 35 Table 4.1 Output Registers 52 Table 4.2 Status Flags (Registers 40201-40232) 52 Table 4.3 Status Flags (Registers 40401-40432) 52

5 EIA-232 Interface 63 Table 5.1 Main Menu Commands 65 Table 5.2 Main Configuration Menu (SC) Commands 66 Table 5.3 IP Configuration Menu Commands 67

A Analog Input 4-20mA Reference Chart 79 Table A.1 Analog Input 4-20mA Reference Chart 79

C Alarm ID Reference Tables 87 Table C.1 Analog Alarm ID Reference Tables, Inputs 1-4 87 Table C.2 Thermistor Alarm ID Reference Tables, Inputs 5-8 88 Table C.3 Digital Alarm ID Reference Tables, Digital Inputs 5 through 32 89

D Technical Specifications 91 Table D.1 Technical Specifications 91

rletech.com 11 970.484.6510

Page 12 of the Falcon Digital Video Recorder (F1000) user manual — Notes:
Page 12 · click to enlarge
Page 12

Notes:

970.484.6510 12 rletech.com

Page 13 of the Falcon Digital Video Recorder (F1000) user manual — C H A P T E R
Page 13 · click to enlarge
Page 13

C H A P T E R

C HAPTER 0 S YSTEM O VERVIEW

1.1. Product Description

The F3400/F1000 monitoring system is a comprehensive system which provides additional equipment protection by monitoring critical operating parameters in enterprises, remote network facilities, communication rooms, remote and unmanned facilities, and critical support systems. The F3400/F1000 is a stand alone system. It operates via an embedded Web server that handles all data collection, alarm reporting, and multiple concurrent communication mediums.

The F3400/F1000 typically monitors analog and dry contact outputs from devices such as temperature sensors, humidity sensors, thermistors, gas detectors, smoke detectors, fire suppression systems, surveillance products (e.g., IP cameras), leak detection systems, power monitoring systems, uninterruptible power supplies (UPSs), power distribution units (PDUs), generators, DC power plants, commercial power, HVAC units, ATS and TVSs.

The F3400/F1000 performs internal diagnostics that check the Flash Program code, serial ports, RAM, non-volatile RAM, real-time clock, internal power supplies, relay drivers, analog to digital converter (ADC), and modem. During operation, the F3400/F1000 monitors its status and uses several LED indicators to report its condition.

The F3400/F1000’s embedded firmware enables system configuration, I/O setup, status inquiries, alarm reports, data logs, and troubleshooting. The F3400/F1000 is menu driven and operates with any Web browser, ASCII terminal or terminal emulation application such as HyperTerminal.

Page 14 of the Falcon Digital Video Recorder (F1000) user manual — 1.2. Front Panel Indicators and Controls
Page 14 · click to enlarge
Page 14

1.2. Front Panel Indicators and Controls

Figure 1.1 Front Panel Indicators and Controls

Communications LEDs – Four Modem Status LEDs

TX – Green (On) if information is being transmitted.

RX – Green (On) if information is being received.

OH – Green (On) if the Modem detects a dial tone (off hook).

CD – Green (On) if a carrier is detected.

Fault – Red if an alarm is present, green if system in normal.

Network LEDs – Two Network Status LEDs

Link – Green if network link is established.

Active – Green (On) if transmitting or receiving data.

Power LED – Green (On) if power is on.

1 System Overview · System Status LED

Page 15 of the Falcon Digital Video Recorder (F1000) user manual — 1.3. Terminal Block Designations
Page 15 · click to enlarge
Page 15

1.3. Terminal Block Designations

Table 1.1 Terminal Block Designations

TB1-1 (+) Input for 24VDC power

TB1-2 (-) Input for 24VDC power

P1 24VDC wall adapter input (center +)

TB2-1 Channel 1 positive (+)

TB2-2 Channel 1 negative (-)

TB2-3 Channel 1 ground (c)

TB2-4 Channel 2 positive (+)

TB2-5 Channel 2 negative (-)

TB2-6 Channel 2 ground (c)

TB2-7 Channel 5 positive (+)

TB2-8 Channel 5 negative (-)

TB2-9 Channel 6 positive (+)

TB2-10 Channel 6 negative (-)

TB2-11 Channel 3 positive (+)

TB2-12 Channel 3 negative (-)

TB2-13 Channel 3 ground (c)

TB2-14 Channel 4 positive (+)

TB2-15 Channel 4 negative (-)

TB2-16 Channel 4 ground (c)

TB2-17 Channel 7 positive (+)

TB2-18 Channel 7 negative (-)

TB2-19 Channel 8 positive (+)

TB2-20 Channel 8 negative (-)

TB3-1 Relay 1 NC

TB3-2 Relay 1 NO

TB3-3 Relay 1 Common

TB3-4 Relay 2 NC

TB3-5 Relay 2 NO

TB3-6 Relay 2 Common

P2 COM1 EIA232 male DB9 pin connector (configurable)

1 System Overview

Page 16 of the Falcon Digital Video Recorder (F1000) user manual — 1.3. Terminal Block Designations
Page 16 · click to enlarge
Page 16

Table 1.1 Terminal Block Designations (continued)

TB4-1 COM1 EIA 485 positive (+) (configurable)

TB4-2 COM1 EIA 485 negative (-) (configurable)

TB4-3 EIA 485 ground

TB4-4 COM1 EIA485 positive (+) (configurable)

TB4-5 COM1 EIA485 negative (-) (configurable

SW1-1 Unit EIA485 termination switch

SW1-2 Two or four wire EIA485 termination.

P3 RJ45 Ethernet 10BASE-T connector

P4 RJ11 telephone line connector

TB5- 1 Channel 9 positive (+)

TB5- Channel 9 negative (-)

TB5- 3 Channel 10 positive (+)

TB5- 4 Channel 10 negative (-)

TB5- 5 Channel 11 positive (+)

TB5- 6 Channel 11 negative (-)

TB5- 7 Channel 12 positive (+)

TB5- 8 Channel 12 negative (-)

TB5- 9 Channel 13 positive (+)

TB5-10 Channel 13 negative (-)

TB5-11 Channel 14 positive (+)

TB5-12 Channel 14 negative (-)

TB5-13 Channel 15 positive (+)

TB5-14 Channel 15 negative (-)

TB5-15 Channel 16 positive (+)

TB5-16 Channel 16 negative (-)

TB5-17 Channel 17 positive (+)

TB5-18 Channel 17 negative (-)

TB5-19 Channel 18 positive (+)

TB5-20 Channel 18 negative (-)

TB5-21 Channel 19 positive (+)

TB5-22 Channel 19 negative (-)

TB5-23 Channel 20 positive (+)

1 System Overview · TB4-6 EIA485 ground

Page 18 of the Falcon Digital Video Recorder (F1000) user manual — 1.5. SW1 Switch Settings
Page 18 · click to enlarge
Page 18

1.4. Rear Panel Indicators

The rear panel of the F3400/F1000 houses a pair of green LEDs. The chart below tracks indicator status when the corresponding green LED is illuminated:

Table 1.2 Rear Panel Status Indicators

EIA232 or EIA485 TX (COM1) Interface Data is being transmitted.

EIA232 or EIA485 RX (COM1) Interface Data is being received.

Falcon Digital Video Recorder (F1000) — 1.4. Rear Panel Indicators diagram (page 18)
Fig. 2 · 1.4. Rear Panel Indicators

Figure 1.3 Rear LED Indicator and Status

1.5. SW1 Switch Settings

SW1-1EIA485 Termination switch should be On (down) if the F3400/F1000 is the end

device on an EIA485 network. The switch should in the OFF (up) position if the device is at the beginning or in the middle of an EIA485 network.

SW1-2EIA485 Termination switch should be On (down) if the device is connected via a

four wire connection. OFF (up) if the device is connected via a two wire connection.

Falcon Digital Video Recorder (F1000) — 1.5. SW1 Switch Settings diagram (page 18)
Fig. 3 · 1.5. SW1 Switch Settings

Figure 1.4 SW1 Switch Is On and SW2 Switch Is Off

1 System Overview

Page 19 of the Falcon Digital Video Recorder (F1000) user manual — 2.3. Set the F3400/F1000’s IP Address
Page 19 · click to enlarge
Page 19

C H A P T E R

C HAPTER 0 G ETTING S TARTED

2.1. Installation

The F3400/F1000 comes in a 19 inch (.48m) rack mount enclosure. Install the F3400/F1000 in the rack. Use the proper anchoring method to mount the unit securely. Supply the 24VDC to the unit.

2.2. Communication

The F3400/F1000 will not communicate over a user’s network the first time it is connected to the network. The manufacturer programs the F3400/F1000 with a default IP address: 10.0.0.186, subnet: 255.255.255.0. This default address must be changed to an IP address that corresponds with the user's network before the F3400/F1000 can communicate over the network.

2.3. Set the F3400/F1000’s IP Address

There are four ways to set the F3400/F1000’s IP address:

Via the ARP and PING commands

Via the Web browser

Via the EIA232 interface

Via Telnet commands

Page 20 of the Falcon Digital Video Recorder (F1000) user manual — PING 192.168.1.14
Page 20 · click to enlarge
Page 20

2.3.1 Set the F3400/F1000's IP Address using the ARP and PING Commands

To set the IP address of a manufacturer programmed F3400/F1000, you can use the ARP (Address Resolution Protocol) command together with the PING (ICMP echo request) command. However, before using these commands, you must know the Ethernet address of the F3400/F1000.

2.3.1.1 Obtain the Ethernet Address

Each network device must have its own unique identification. This identification sets it apart from all other manufacturers and ensures that no two network devices have the same address. Each manufacturer must use a six digit numbering convention, the first three digits determine the actual manufacturer and the remaining three digits determine the unique network serial number of each individual device.

A typical Ethernet address (also known as a MAC address - Media Access Control) from the F3400/F1000 looks like this: 00:90:5B:00:02:45

You can find the Ethernet (MAC) address of your F3400/F1000 by looking at the model number sticker located on the bottom of the device.

2.3.1.2 Use the ARP Command

Once you know the Ethernet address of the F3400/F1000, use the ARP command with the correct parameters from any computer located on the F3400/F1000's subnet (e.g., Class C with a net mask of 255.255.255.0).

For example, enter the following from a command prompt:

arp -s 192.168.1.14 00-90-5b-00-02-45

This command tells the computer (from which the ARP command was entered) that the network device with an IP address of 192.168.1.14 uses the Ethernet (MAC) address of 00-90-5b-00-02-45.

2.3.1.3 Use the PING Command

After the ARP command has been entered, the PING command must be entered from the same computer in order to set up the IP address of the F3400/F1000. The PING command will use the ARP entry added from 2.3.1.1, “Obtain the Ethernet Address” on page 20, to send the IP address information directly to the F3400/F1000 (which is just one of several methods to initially configure the IP address on a new F3400/F1000).

To do this, enter the following from a command prompt:

Where “ip_address”' is the IP address you entered using the ARP command. In the above example, the following would be entered:

PING 192.168.1.14

This changes the IP address of the F3400/F1000 to: 192.168.1.14.

2 Getting Started · PING ip_address

Page 21 of the Falcon Digital Video Recorder (F1000) user manual — 2.3.2 Set the F3400/F1000’s IP Address using a Web Browser
Page 21 · click to enlarge
Page 21

2.3.1.4 Troubleshooting the ARP/PING Commands

If problems are encountered, it may be for one of the following reasons:

The F3400/F1000 already has a non-default TCP/IP address. Once the IP address of the

F3400/F1000 has been changed from the default of 10.0.0.186, it is not possible to change it again with the ARP/PING commands. This method of setting up the F3400/F1000's IP address can only be used on a F3400/F1000 that still has its original default IP address, as shipped from the manufacturer.

The device is not on the same Class C subnet as the computer from which the ARP/PING

commands were sent. The F3400/F1000's default router and net mask must be changed via a Web browser pointed at the F3400/F1000's default IP address (i.e., http://10.0.0.186) or via a direct EIA232 terminal connection to the F3400/F1000-both of which are alternate methods for setting up the F3400/F1000's IP address.

2.3.2 Set the F3400/F1000’s IP Address using a Web Browser

1 Plug a crossover network cable into the laptop or workstation that will be used to configure the F3400/F1000. This cable is not intended to be connected to a network hub.

2 Write down the computer's IP address and Subnet Mask. Then change the IP address and Subnet Mask of the computer from its existing address to one that will allow it to communicate with the F3400/F1000, such as 10.0.0.188. It may be helpful to set the IP address to one that is one number different from the F3400/F1000's IP address. Consult the computer's manual or your IT Department before attempting this.

3 Connect the other end of the network cable to the Ethernet port on the back of the F3400/ F1000. Access the F3400/F1000 through a Web browser by typing the IP address into the location bar. Enter the F3400/F1000 user name and password when prompted.

4 Select the Configuration link, then select the Internet Protocol link and change the IP Address, Net Mask, and Def Route to one provided by the network administrator. Press the Submit Changes button. The F3400/F1000 will save the new IP address and reboot. Once the F3400/F1000 reboots completely, the system status LED will stop flashing.

5 5Change the IP address of the computer back to its original IP address. If the computer was configured as DHCP (the network domain controller assigns an IP address) return it to this state. This may require assistance from your IT Department, or you may need to consult the computer's manual.

6 6The computer and the F3400/F1000 are now both configured to communicate on the network. Both should be accessible via the network. Connect the PC and the F3400/F1000 to the network. From the PC Web browser, type in the IP address of the F3400/F1000. Enter the user name and password.

2 Getting Started

Page 22 of the Falcon Digital Video Recorder (F1000) user manual — 2.3.4 Set the F3400/F1000's IP Address using a Telnet Connection
Page 22 · click to enlarge
Page 22

2.3.3 Set the F3400/F1000’s IP Address Using an EIA232 Connection

To use the EIA232 interface:

1 Connect the EIA232 port (P2 EIA232 - COM1) on the F3400/F1000 to a terminal or PC running terminal emulation software (HyperTerminal) with a 9-pin male-female straight through serial cable (a serial cable is supplied with the F3400/F1000).

2 2Set the appropriate communication port to 9600 baud, NO parity, 8 data bits, 1 stop bit, (9600/N/8/1), and no software or hardware flow command.

3 Once the terminal emulation software starts, press Enter on the keyboard and the Main Menu should appear. If the Main Menu does not appear, check the communication settings and make sure the unit is powered on.

4 From the Main Menu type “SC” to select the System Configuration Menu.

5 From the main configuration menu type “1” to select the IP Configuration Menu.

6 From the IP Configuration Menu type “i” to change the IP address.

7 Enter the new IP address for the F3400/F1000. Separate each field with a decimal point - for example type 10.0.0.50 .

8 Enter “x” to Exit and Save the new IP address F3400/F1000 will erase a memory block and copy data to Flash memory before rebooting.

9 The F3400/F1000 IP address is now set and the F3400/F1000 can be accessed through a Web browser using the new IP address.

Refer to Chapter 5, “EIA-232 Interface” on page 63 for more information on the EIA232 command set.

2.3.4 Set the F3400/F1000's IP Address using a Telnet Connection

To use the Telnet interface:

1 Open a command prompt from your PC/Laptop.

2 Type in the Telnet, space, and the IP address of the Falcon. Once connected enter the user name and password; default user name is falcon (all lowercase) and no password (e.g., C:\>telnet 10.0.0.186).

3 To change the IP Address type ip, space, and the new IP address of the Falcon. Press enter.

4 To change the Subnet Mask, type “sn” space, and the new Subnet Mask number. Press enter.

5 To change the Default Gateway, type “dg”, space, and the new Default gateway number. Then press enter.

2 Getting Started

Page 23 of the Falcon Digital Video Recorder (F1000) user manual — 2.4.1 Power Supply and Ground Connections
Page 23 · click to enlarge
Page 23

2.4. F3400/F1000 Wiring

RLE Technologies recommends an 18AWG stranded copper wire for connection from each monitored point to a terminal block (TB) connection on the F3400/F1000. RLE recommends no more than 500 feet (152.4m) of wire at this specification. If longer runs are needed, please contact RLE Technologies for application guidance. Shielded twisted pair wiring is recommended for analog signal transmitters being wired outside of conduit runs and dropped ceiling applications.

2.4.1 Power Supply and Ground Connections

Connect an 18AWG ground wire from the ground terminal to a suitable earth ground. Plug the wall adapter into P1 and a UPS outlet as shown below. The wall adapter has a five foot power cord. RLE Technologies recommends powering the F3400/F1000 from a UPS supply to allow the F3400/F1000 to send alarm notification during a power outage.

Falcon Digital Video Recorder (F1000) — 2.4.1 Power Supply and Ground Connections diagram (page 23)
Fig. 4 · 2.4.1 Power Supply and Ground Connections

Figure 2.1 24 VDC Power Supply Connection

2 Getting Started

Page 24 of the Falcon Digital Video Recorder (F1000) user manual — 2.4.3 RJ11 Phone Line Connection
Page 24 · click to enlarge
Page 24

2.4.2 EIA232 COM1 Connection

The EIA232 port can be connected to a PC for local configuration, firmware downloads, and troubleshooting. It is typically a temporary connection. Connect the straight through, 9-pin, cable as shown in Figure 2.2.

Falcon Digital Video Recorder (F1000) — 2.4.2 EIA232 COM1 Connection diagram (page 24)
Fig. 5 · 2.4.2 EIA232 COM1 Connection

Figure 2.2 EIA232 COM1 Connection

2.4.3 RJ11 Phone Line Connection

The F3400/F1000 (with modem option the model no. would be F3400-M/F1000-M) contains an internal modem for dial in and dial out capabilities. The modem can be used for:

Remote connection to accomplish a variety of tasks, including: viewing alarms, changing

configurations, and acknowledging alarms.

Pager notification to text, numeric pager or alpha-numeric pager (TAP changer). Text and

numeric pagers do not use a TAP changer.

2 Getting Started

Page 25 of the Falcon Digital Video Recorder (F1000) user manual — 2.4.4 RJ45 Ethernet Connection
Page 25 · click to enlarge
Page 25

2.4.4 RJ45 Ethernet Connection

The F3400/F1000 has an internal 10BASE-T Ethernet port used to configure and monitor the F3400/F1000. The Ethernet port supports Web browser access, email (SMTP), BACnet, and SNMP. The following figures show the physical connections; refer to Chapter 4, “Configuration Menu” on page 35, for more detail on the Ethernet port. Figure 2.3 shows a direct connection between the F3400/F1000 and a PC using a crossover cable. Figure 2.4 shows a typical F3400/F1000 connection on a subnet using a hub or switch and straight through CAT5 cables.

Falcon Digital Video Recorder (F1000) — 2.4.4 RJ45 Ethernet Connection diagram (page 25)
Fig. 6 · 2.4.4 RJ45 Ethernet Connection

Figure 2.3 F3400/F1000 Ethernet Connection to a PC using a Crossover Cable

Falcon Digital Video Recorder (F1000) — 2.4.4 RJ45 Ethernet Connection diagram (page 25)
Fig. 7 · 2.4.4 RJ45 Ethernet Connection

Figure 2.4 F3400/F1000 Ethernet Connection to a PC on a Subnet

2 Getting Started

Page 26 of the Falcon Digital Video Recorder (F1000) user manual — 2.4.5 Relay K1 and K2 Connection
Page 26 · click to enlarge
Page 26

2.4.5 Relay K1 and K2 Connection

Relay outputs may be used to unlatch doors, signal annunciators, signal IP cameras, and to turn on auxiliary equipment such as exhaust fans. Relay outputs are Form C (SPST). Refer to Appendix D, “Technical Specifications” on page 91 for relay contact ratings. Relays may be wired for Normally Open (NO), or Normally Closed (NC) signals. See Figure 2.5 for examples.

Falcon Digital Video Recorder (F1000) — 2.4.5 Relay K1 and K2 Connection diagram (page 26)
Fig. 8 · 2.4.5 Relay K1 and K2 Connection

Figure 2.5 F3400/F1000 Relay Output Wiring Examples

2 Getting Started

Page 27 of the Falcon Digital Video Recorder (F1000) user manual — 3.2. Main Menu
Page 27 · click to enlarge
Page 27

C H A P T E R

C HAPTER 0 F3400/F1000 W EB I NTERFACE

3.1. F3400/F1000 Web Interface Overview

The F3400/F1000's Web interface provides a convenient way to check the F3400/F1000’s status and reconfigure basic settings from any Internet enabled computer.

The F3400/F1000 is shipped to the user with the IP address configured as 10.0.0.186 and a subnet of 255.255.255.0. The user name is preconfigured as Falcon. The unit is configured without a password; when a password is requested, just leave the space blank. These pre- configurations can be customized through the Internet Protocol link on the Configuration Menu of the Web interface. To change the F3400/F1000 IP address, refer to 2.3., “Set the F3400/F1000’s IP Address” on page 19.

3.2. Main Menu

Falcon Digital Video Recorder (F1000) — 3.2. Main Menu diagram (page 27)
Fig. 9 · 3.2. Main Menu

Figure 3.1 Example of F3400/F1000’s Main Menu

To access the F3400/F1000’s Main Menu, type the IP address of the F3400/F1000 into the location bar of the Web browser. Then enter a user name and password.

Page 28 of the Falcon Digital Video Recorder (F1000) user manual — 3.2.1.1 Alarm History
Page 28 · click to enlarge
Page 28

3 F3400/F1000 Web Interface

The top of the page provides links to other pages for additional monitoring, control and configuration. The Falcon logo (default), IP camera image or company logo can be displayed on the Main Menu.

The bottom of the F3400/F1000 Main Menu features columns that list the F3400/F1000's configured inputs. The number of inputs displayed is configurable from the System Configuration page, explained below. Each input is numbered. The input's name is followed by its status. The space behind each input is shaded. This shading changes as the input's status changes. This allows users to see, at a glance, the status of their points. Color codes are as follows:

Green: Input is normal—not in an alarm state.

Yellow: Analog inputs only—input is in a high alarm 1 or low alarm 1 state.

Red: Analog input is in a high alarm 2 or low alarm 2 state. Digital input is in an alarm state.

Blue: Alarm/Input disabled by a schedule.

White (no shading): Input is not configured - spare point for future use.

Magenta, Green or GoldDigital Status point is on. This color is configurable under the

Configuration - System menu.

3.2.1 Historical Data

Historical Data provides an intermediate page to assist in navigating to desired data.

3.2.1.1 Alarm History

Alarm History displays the last 100 alarms captured by the F3400/F1000. Alarms are ranked from most recent (top of the page) to lest recent (bottom of the page).

Falcon Digital Video Recorder (F1000) — 3.2.1.1 Alarm History diagram (page 28)
Fig. 10 · 3.2.1.1 Alarm History

Figure 3.2 Example of the Alarm History Page

Page 29 of the Falcon Digital Video Recorder (F1000) user manual — 3.2.1.2 Event History
Page 29 · click to enlarge
Page 29

3 F3400/F1000 Web Interface

The following format is used to record each alarm entry:

AH###-ID-Condition-Date Time (Value UOM) Label

AH### is the alarm entry index.

ID is the alarm identifier number; refer to Appendix C, “Alarm ID Reference Tables” on

page 87.

Condition is On, High1, High2, Low1, Low2, or RTN (Returned to Normal).

Date and Time is the internal date and time stamp of the alarm condition.

Label is the alarm descriptor, up to 64 characters long.

Value and Unit of Measure (UOM) is captured for analog channels only. The value recorded

is the actual analog value that exceeded its alarm threshold.

The Alarm History log entries are color coded as follows:

Red: A point that is configured for dial out (pager) is in alarm and is unacknowledged. The

alarm will be red if the point is configured for both pager and email notification.

Blue: The alarm has been acknowledged.

Black: The alarm has returned to normal.

Unacknowledged dial out alarms (marked in red) can be acknowledged from this page. To acknowledge an alarm, type the appropriate code in the box at the bottom of the page and click the Acknowledge Alarms by Code button. Acknowledge codes are set under the Phone Number Configuration pages. Refer to 4.5.1, “Configure Phone Numbers” on page 44, for more information on configuring phone numbers.

3.2.1.2 Event History

Falcon Digital Video Recorder (F1000) — 3.2.1.2 Event History diagram (page 29)
Fig. 11 · 3.2.1.2 Event History

Figure 3.3 Example of the Event History Page

Event History displays the past 100 events, as recorded by the F3400/F1000. Typical events logged are System Booted, Email Accepted by Server, No Dial Tone, Busy, No Carrier, Page Successful, Alarm History Cleared, Digital Status History Cleared, Force Acknowledge by , Program Upload - TFTP, etc.

Page 30 of the Falcon Digital Video Recorder (F1000) user manual — 3.2.1.4 Web User Access Log
Page 30 · click to enlarge
Page 30

3 F3400/F1000 Web Interface

3.2.1.3 Digital Status History

Falcon Digital Video Recorder (F1000) — 3.2.1.3 Digital Status History diagram (page 30)
Fig. 12 · 3.2.1.3 Digital Status History

Figure 3.4 Example of the Digital Status History Page

Digital Status History displays a history of the state of digital points configured as “Status” points. A digital input can be configured as NO (normally open), NC (normally closed), or Status. If the digital input is configured as Status, it will not alarm, but any changes will be noted and appear on this page. The log displays the past 100 status changes, as recorded by the F3400/F1000.

3.2.1.4 Web User Access Log

Falcon Digital Video Recorder (F1000) — 3.2.1.4 Web User Access Log diagram (page 30)
Fig. 13 · 3.2.1.4 Web User Access Log

Figure 3.5 Example of Web User Access Log Page

The Web User Access Log records the most recent 100 Web interface users.

Page 31 of the Falcon Digital Video Recorder (F1000) user manual — 3.2.1.6 Minute, Hour, and Day View
Page 31 · click to enlarge
Page 31

3 F3400/F1000 Web Interface

3.2.1.5 Data History

Falcon Digital Video Recorder (F1000) — 3.2.1.5 Data History diagram (page 31)
Fig. 14 · 3.2.1.5 Data History

Figure 3.6 Example of the Data History Page

Data History provides an intermediate page to assist in navigating to the desired data. Only points configured as analog 4-20mA and thermistor are shown.

The Data History Text Downloads link allows the Alarm History Log to be downloaded as

a text (.txt) file and the Minute, Hour and Day logs to be downloaded as a comma separated variable (.csv) file.

3.2.1.6 Minute, Hour, and Day View

Falcon Digital Video Recorder (F1000) — 3.2.1.6 Minute, Hour, and Day View diagram (page 31)
Fig. 15 · 3.2.1.6 Minute, Hour, and Day View

Figure 3.7 Day View Example

The Minute, Hour, and Day links on the Data History page display the detailed information the F3400/F1000 records in its logs. The Minute log displays the high, low and average values per minute for the last 60 minutes. The Hour log displays the high, low and average values per hour for the last 24 hours. The Day log displays the high, low and average values per day for the last seven (7) days. These values can be downloaded to a comma separated variable (.csv) file via the Data History Text Downloads button.

Page 32 of the Falcon Digital Video Recorder (F1000) user manual — 3.2.1.8 Server History
Page 32 · click to enlarge
Page 32

3 F3400/F1000 Web Interface

3.2.1.7 Data History Text Downloads

This link helps navigate to the desired data.

Falcon Digital Video Recorder (F1000) — 3.2.1.7 Data History Text Downloads diagram (page 32)
Fig. 16 · 3.2.1.7 Data History Text Downloads

Figure 3.8 Example of the Data History Text Download Page

3.2.1.8 Server History

Falcon Digital Video Recorder (F1000) — 3.2.1.8 Server History diagram (page 32)
Fig. 17 · 3.2.1.8 Server History

Figure 3.9 Example of the Server History Page

Server History displays the past 100 events for all servers, as recorded by the F3400/F1000. The following format is used to record each entry: NH###-ID-Condition-Date Time Label

Page 33 of the Falcon Digital Video Recorder (F1000) user manual — 3.3. Identity
Page 33 · click to enlarge
Page 33

3 F3400/F1000 Web Interface

3.2.1.9 Server Status

Falcon Digital Video Recorder (F1000) — 3.2.1.9 Server Status diagram (page 33)
Fig. 18 · 3.2.1.9 Server Status

Figure 3.10 Example of the Server Status Page

Server Status displays the current status of each server selected to be monitored. The Status field is color coded. White indicates the relay output is de-energized; red indicates that the relay output is energized; green indicates relay output is in normal status. To setup server(s), refer to 4.17., “Email” on page 58.

3.3. Identity

Falcon Digital Video Recorder (F1000) — 3.3. Identity diagram (page 33)
Fig. 19 · 3.3. Identity

Figure 3.11 Example of the F3400/F1000 Identity Page

Identity displays basic F3400/F1000 information including Model Number, System Name, MAC Address, Firmware Version, and IP Address.

Page 34 of the Falcon Digital Video Recorder (F1000) user manual — 3.5. Configuration
Page 34 · click to enlarge
Page 34

3 F3400/F1000 Web Interface

3.4. Web Links

Falcon Digital Video Recorder (F1000) — 3.4. Web Links diagram (page 34)
Fig. 20 · 3.4. Web Links

Figure 3.12 Example of the Web Links Display Page

Web links displays still images (.jpg) from all IP cameras and other URLs linked to the F3400/ F1000.

3.5. Configuration

Falcon Digital Video Recorder (F1000) — 3.5. Configuration diagram (page 34)
Fig. 21 · 3.5. Configuration

Figure 3.13 Configuration Menu

The Configuration link provides access to a series of menus from which qualified users can make adjustments to the F3400/F1000’s settings; see Chapter 4, “Configuration Menu” on page 35, for a more detailed explanation.

Page 35 of the Falcon Digital Video Recorder (F1000) user manual — C H A P T E R
Page 35 · click to enlarge
Page 35

C H A P T E R

C HAPTER 0 C ONFIGURATION M ENU

The Configuration page allows users with administrator or read-write privileges to adjust the F3400/F1000’s settings. Each link on the Configuration page displays more information about specific configuration settings.

Figure 4.1 Configuration Menu

Page 36 of the Falcon Digital Video Recorder (F1000) user manual — 4.1. Inputs
Page 36 · click to enlarge
Page 36

4.1. Inputs

Falcon Digital Video Recorder (F1000) — 4.1. Inputs diagram (page 36)
Fig. 22 · 4.1. Inputs

Figure 4.2 Inputs Configuration Page

Inputs allow users to program specific parameters for each F3400/F1000 input. This model allows different numbers of inputs. Only installed inputs are displayed. Inputs are identified by their name and slot channel number (S.Ch).

This page will be displayed when configuring the F3400/F1000’s main board inputs, channels 1-32. The options on this page are described below:

Input Reading: Displays the input current as sensed by the F3400/F1000 and the calculated value based on the offset and gain settings.

Example: A current input of 10.5mA from the temperature sensor would convert to a value of 68.0°F. When the input Type is Digital NO, Digital NC or Digital Status, the Calculated Value will be a 0 or 1, with 1 representing an alarm condition.

Page 37 of the Falcon Digital Video Recorder (F1000) user manual — 4.1. Inputs
Page 37 · click to enlarge
Page 37
Select Input TypeSelect based on the type of device connected to the input channel. Options include:

Not Configured – Select when there is nothing connected to the input.

Analog 4-20mA – Select when the device connected to the input provides a 4-20mA output.

Digital NO – Select when the device connected to the input is a dry contact that is normally

open and closes on an alarm condition.

Digital NC – Select when the device connected to the input is a dry contact that is normally

closed and open on an alarm condition.

Digital Status – Select when the device connected to the input is a dry contact that only

needs to be monitored (status only), without alarms.

Thermistor – Select when the device connected to the input provides resistance output.

Gain and Offset: Applies only to Analog 4-20mA input types. Inputs like temperature, humidity, pressure, etc. sensors connected to the F3400/F1000 convert information to a 4- 20mA signal. The F3400/F1000 reads this raw 4-20mA signal and calculates a value based on the input and the predetermined gain and offset settings. The idea is to determine the correct gain and offset values so that the F3400/F1000 calculates and displays an accurate reading - one that corresponds closely to the sensor's reading (e.g., if the sensor measures a temperature of 50°F, the F3400/F1000 should display 50°F; if the sensor measures a temperature of 95°F, the F3400/F1000 should display 95°F). If the gain and offset settings are incorrect, the F3400/ F1000 will calculate an incorrect value. Since the F3400/F1000's reading will not match the sensor's reading, over the entire sensor range, missed alarms or nuisance alarms could result.

To set gain and offset values, click the Calculator link.

Falcon Digital Video Recorder (F1000) — 4.1. Inputs diagram (page 37)
Fig. 23 · 4.1. Inputs

Figure 4.3 Calculator Link

Enter the sensor’s range and press the Calculate button. Click the Return to Input Configuration link and the gain and offset fields will be automatically entered with the correct offset and gain settings. Gain and offset values can also be determined by using the following formulas:

Gain for 4-20mA Transducer = (Sensor High Range Value- Sensor Low Range Value) / 4 Offset for 4-20mA Transducer = Sensor Low Range Value - Gain

Page 38 of the Falcon Digital Video Recorder (F1000) user manual — 4.1. Inputs
Page 38 · click to enlarge
Page 38
ExampleTemperature sensor with a sensing range of 50-95°F - displayed in Fahrenheit

Gain = (95-50) / 4 = 11 (round to the nearest integer) Offset = 50 - 11 = 39

ExampleTemperature sensor with a sensing range of 50-95°F - displayed in Celsius

Convert 50-95°F to 10-35°C and use the Celsius range for the calculations Gain = (35-10) / 4 = 6 (round to the nearest integer) Offset = 10 - 6 = 4

ExampleHumidity sensor with a range of 0 - 100% RH

Gain = (100-0) / 4 = 25 Offset = 0 - 25 = -25

High Limit 2: Applies only when the input type is Analog 4-20mA. The F3400/F1000 will record an alarm and send notification when the F3400/F1000's calculated value exceeds this limit. The High Limit 1 and High Limit 2 are disabled when they are both set to 0.

High Limit 1: Applies only when the input type is set for Analog 4-20mA. The F3400/F1000 will record an alarm and send notification when the F3400/F1000’s calculated value exceeds this limit. The High Limit 1 and High Limit 2 are disabled when they are both set to 0.

Low Limit 1: Applies only when the input type is Analog 4-20mA. The F3400/F1000 will record an alarm and send notification when the F3400/F1000's calculated value falls below this limit. The Low Limit 1 and Low Limit 2 are disabled when they are both set to 0.

Low Limit 2: Applies only when the input type is Analog 4-20mA. The F3400/F1000 will record an alarm and send notification when the F3400/F1000's calculated value falls below this limit. The Low Limit 1 and Low Limit 2 are disabled when they are both set to 0.

Unit Of Measure (UOM): The 10 character field used to assign a unit of measure label to analog values, such as °F, °C, % RH, Amps, Volts, PSI, etc. The unit of measure field is only required when the input type is Analog 4-20mA. The unit of measure field is displayed on the Main Menu and in notification (email/pager messages and SNMP Trap).

Alarm Label: Used for input identification. Applies to all input types except “Not Configured”. For Analog input types, this label is displayed on the F3400/F1000 Main Menu and the Input Configuration Menu. When the input alarms and/or returns to normal, the label is included in the Alarm History and notification messages. For Digital NO and Digital NC inputs, the label is displayed on the F3400/F1000 Main Menu, Input Configuration Menu, Alarm History page and in notification messages only when the device is in alarm. For Digital Status inputs, the label is displayed on the F3400/F1000 Main Menu when the input is on. When the input turns on, the label is also included in the Digital Status History.

Normal Label: Applies to input types Digital NO, Digital NC and Digital Status. This field may be left blank. If it is left blank, the F3400/F1000 displays the Label (from above). This label is displayed on the main page when the input is normal, in the Alarm History when the input returns to normal and in notification messages. For Digital Status inputs, the label is displayed on the main page when the input is off. When the input turns off, the label is also included in the Digital Status History.

Page 39 of the Falcon Digital Video Recorder (F1000) user manual — 4.1. Inputs
Page 39 · click to enlarge
Page 39

Alarm Delay: The amount of time the F3400/F1000 waits to send an alert after an alarm condition is detected. The F3400/F1000 uses this same time delay to report a return to normal after the alarm condition clears. The alarm delay is active for all input types except Not Configured.

Example:

An input is configured as a digital NO, labeled “CRAC UNIT ALARM” and has an alarm delay of 10 seconds. When the CRAC unit alarms, it closes the contact to the F3400/F1000. If the CRAC unit returns to normal and opens the contact to the F3400/F1000 within the 10 second alarm delay, no alarm is generated in the F3400/F1000. If the CRAC unit remains in alarm for 10 seconds or more, the F3400/F1000 records the alarm and generates notification per the input settings. If the CRAC unit returns to normal and alarms within the 10 second alarm delay, the F3400/F1000 does not record it as a return to normal. Once the CRAC unit returns to normal for the 10 second alarm delay, the F3400/F1000 records a return to normal and generators notification per the F3400/F1000 settings.

Hysteresis: The number that designates the amount an input reading must sway from its preset alarm reading before it is classified as returned to normal. The Hysteresis provides a deadband around the limit settings to prevent several alarms and return to normal alarms when the input is the same as a limit setting.

The Hysteresis applies when the input type is Analog 4-20mA or thermistor and is active for High Limit 1, High Limit 2, Low Limit 1 and Low Limit 2.

Example:

A temperature sensor alarms when it reaches its High Limit 1 of 80°F. If Hysteresis is set at four, the sensor must register less than 76°F before the F3400/F1000 reports it as returned to normal. In another example, a humidity sensor alarms when it reaches its Low Limit 2 of 30% RH. If the Hysteresis is set at five, the humidity must register more than 35% before the F3400/F1000 reports it as returned to normal.

Relay Activate: Used to assign a Threshold change to analog inputs, or Digital Alarm generated by this input to a specific relay. To select the relay, check the relay box. This feature can be set to activate on a High 2/Low 2 threshold for analog points, in the Relay configuration menu

Dial Out Notification: The list of up to 4 pager numbers to which the F3400/F1000 sends alarm notification. The numbers correspond to phone numbers configured from the Configure Phone Number links at the bottom of the Modem Configuration page. Separate each ID number with a comma. Enter zero to disable. The F3400/F1000 will dial the lowest number listed regardless of the order the numbers are listed. See 4.5.1, “Configure Phone Numbers” on page 44 for more information.

Example:

If the Alarm dial out string is set to “3, 5, 1, 0”, the F3400/F1000 will dial Pager #1, Pager #3 and then Pager #5 when an alarm occurs. Pager notification will be sent when an input alarms (high limit 2, high limit 1, low limit 1, low limit 2 is exceeded or the digital input is in alarm). An option on the Pager Configuration page determines if the F3400/F1000 will send a page when an input returns to normal.

Page 40 of the Falcon Digital Video Recorder (F1000) user manual — 4.2. Relays
Page 40 · click to enlarge
Page 40

Email Recipient Notification: Allows up to four email addresses to be designated for notification if the input goes into alarm. Email addresses will be displayed once they are entered on the Email Configuration page. Email notification will be sent when an input alarms and when an input returns to normal.

Alarm Disable by Schedule: Used to designate a period of time the input will be disabled or inactive. To do this, select either the A or B schedules, which are defined in the Schedule Configuration menu. Within the scheduled time, the point on the Main Menu will turn Blue to indicate that the input is currently being disabled during its scheduled time. Once the scheduled time has past, the point will reactivate and return to its normal color.

BACnet Instance: The BACnet object identifier. It is a numerical code used to identify the input. This code must be unique within the BACnet device.

BACnet Units: A numerical code used to assign engineering units to this BACnet Instance. Refer to the BACnet standard for further information.

4.2. Relays

Falcon Digital Video Recorder (F1000) — 4.2. Relays diagram (page 40)
Fig. 24 · 4.2. Relays

Figure 4.4 Relays Configuration Page

Relays allow users to identify each relay with custom label.

Analog Level 1 Alarm Relay Activation: This allows the users to select if the relays should activate on a High 2 or Low 2 threshold change. Default is set to “Yes”. The relay output is a common summary output to any alarm present to that channel.

Page 41 of the Falcon Digital Video Recorder (F1000) user manual — 4.3. Schedules
Page 41 · click to enlarge
Page 41

4.3. Schedules

Falcon Digital Video Recorder (F1000) — 4.3. Schedules diagram (page 41)
Fig. 25 · 4.3. Schedules

Figure 4.5 Schedules Configuration Menu

The Schedules page allows users to schedule the activation and deactivation of relay outputs. This is useful for cycling redundant equipment such as chillers, generators, etc. Relays are assigned these schedules through the Relay Configuration menus. Begin DOW is the day of the week the schedule will begin, and End DOW is the day of the week the schedule will end.

Page 42 of the Falcon Digital Video Recorder (F1000) user manual — 4.4. Alarm Management
Page 42 · click to enlarge
Page 42

4.4. Alarm Management

Falcon Digital Video Recorder (F1000) — 4.4. Alarm Management diagram (page 42)
Fig. 26 · 4.4. Alarm Management

Figure 4.6 Alarm Management

The Alarm Management link allows users to acknowledge current F3400/F1000 alarms and clear the F3400/F1000's Alarm History Logs. Click the button and enter the appropriate code or user's initials to complete the task.

Page 43 of the Falcon Digital Video Recorder (F1000) user manual — 4.5. Modem
Page 43 · click to enlarge
Page 43

4.5. Modem

The Modem link allows users to configure the F3400-M/F1000’s internal modem (if the option is available). This instructs the F3400-M/F1000-M when, how, and whom to call when an alarm occurs. See definitions below for more information.

Falcon Digital Video Recorder (F1000) — 4.5. Modem diagram (page 43)
Fig. 27 · 4.5. Modem

Figure 4.7 Modem Configuration Page

Initialization String: A maximum of 38 characters. &c1 and &d3 are mandatory. s0=1 sets the modem to answer after one ring. s0=0 disables the auto answer and prevents dial-in access.

Dial Prefix: Should be a specific Hayes compatible command or dial modifier depending on pager requirements. It is also limited to 38 characters. The default is set to atdt.

Pager Deliveries: Designates the number of times (0-255) the pager is called until the alarm is acknowledged. Pagers are called in sequence. For example, if Pager Deliveries is set to 3 and pagers 1, 7, and 10 are programmed to be notified, the F3400/F1000 dials 1, 7, 10, 1, 7, 10, 1, 7, 10. As soon as the alarm is acknowledged, the F3400/F1000 quits dialing the pagers with that particular access code. Pagers with different access codes are still dialed.

Pager Interval: Determines the number of minutes to wait between redials.

Pager Baud Rate: Allows the user to set the pager communications settings.

Pager Resend: Select yes for the F3400/F1000 to send all unacknowledged alarms in the Alarm History Menu. Select no to send only the last unacknowledged alarm. If no is selected, the F3400/F1000 will auto-acknowledge all alarms associated with that particular pager once a successful page has occurred.

Modem Password: Defines a remote access password, seven characters maximum. Used when remotely logging into the F3400/F1000 through a modem.

Redial Attempts: Determines the number of times (1-255) to call a number until the call is successful. Enter 0 to disable this function.

Page 44 of the Falcon Digital Video Recorder (F1000) user manual — 4.5.1 Configure Phone Numbers
Page 44 · click to enlarge
Page 44

Redial Interval: Establishes the number of minutes (1-255) to wait between redials. Enter 0 to disable this function.

Dial Back on Returns: Determines whether to call the number again once the alarm condition returns to normal.

Force Alarm Acknowledge Code: Establishes a code that acknowledges all unacknowledged alarms. This acts as a master code and can override all other alarm acknowledge codes.

4.5.1 Configure Phone Numbers

Falcon Digital Video Recorder (F1000) — 4.5.1 Configure Phone Numbers diagram (page 44)
Fig. 28 · 4.5.1 Configure Phone Numbers

Figure 4.8 Phone Number Configuration Page

This page is accessed through the Config Phone Number link at the bottom of the Modem Configuration page. This screen allows users to configure pager and cell phone numbers that are used for alarm notification.

Select Phone Type: Determines which type of device the F3400/F1000 calls. Select the Text option to dial a PC receiving ASCII strings. Select Numeric Pager to dial a numeric pager. Select the Alpha-numeric Pager option to dial an alpha-numeric pager.

Number: Enter the pager service number for numeric and alphanumeric pager entries. Each comma after the pager number represents a two second delay. This delay is used to allow enough time for the pager service to answer before requesting the pager ID. Typically only one comma is needed. However, experimentation with the proper number of commas may be necessary. In some cases, a 9 must be entered to access an outside line.

Page 45 of the Falcon Digital Video Recorder (F1000) user manual — 4.5.1 Configure Phone Numbers
Page 45 · click to enlarge
Page 45

Pager ID: Mandatory for numeric and alphanumeric pagers.

Alphanumeric pager – The ID entered is sent to the paging service along with all queued

alarm messages. The ID is the unique PIN for a specific pager. The ID may be a maximum of 16 characters.

Numeric pager – The ID entered may be configured to deliver different numeric messages.

The ID can contain 15 characters: any combination of the numerals 0 through 9 and a * or #. These are the only characters that will be transmitted to the paging service.

– Y – Binary Alarm Condition: 1=on, 0=return to normal (RTN)

– ZZZ – Alarm ID Number; see Appendix C, “Alarm ID Reference Tables” on page 87.

Example: A 1001 message is an Input 1, High Limit 1 Alarm. A 0093 message means that Digital Input #13 has returned to normal.

An effective numeric page depends largely on the parameters established by the paging service. Experimentation may be required to achieve desired results.

Acknowledgement Code: Any number, up to six digits, used to acknowledge receipt of an alarm and to terminate any additional call outs for this phone number. This code will acknowledge only those alarms sent to this phone number. It can be acknowledged by selecting the Acknowledge Alarms button on the bottom of the Alarm History page.

Multiple phone numbers can use the same acknowledge code. This allows one user to acknowledge alarms sent to multiple pager numbers.

Page 46 of the Falcon Digital Video Recorder (F1000) user manual — 4.6. Web Links
Page 46 · click to enlarge
Page 46

4.6. Web Links

Falcon Digital Video Recorder (F1000) — 4.6. Web Links diagram (page 46)
Fig. 29 · 4.6. Web Links

Figure 4.9 Configuring Web Links

The Main Menu of the F3400/F1000's Web interface displays a large image and links to other images. These images can be graphics, logos or images from an IP camera. The Web link page allows users to specify which images and URLs will be available on the F3400/F1000's Main Menu.

For Axis207 Web Cameras set the URL link to the following:

URL Link #x Imagehttp://xxx.xxx.xxx.xxx/jpg/image.jpg
URL Link #x Homehttp://xxx.xxx.xxx.xxx
URL Link #x LabelEnter the Camera's Label

For Panasonic KX-HCM10A Web Cameras set the URL link to the following:

URL Link #x Image:

http://xxx.xxx.xxx.xxx/snapshotjpeg?resolution=320x240&quality=standard

URL Link #x Home:

http://xxx.xxx.xxx.xxx/ ImageViewer?Mode=Motion&resolution=320x240&quality=standard

URL Link #x LabelEnter the Camera’s Label

Main WebCam Image Size: Designates the size of the image on the F3400/F1000 main page of 320x240 or 640x480.

Page 47 of the Falcon Digital Video Recorder (F1000) user manual — 4.8. Falcon Links
Page 47 · click to enlarge
Page 47

4.7. Egg/Nest

Falcon Digital Video Recorder (F1000) — 4.7. Egg/Nest diagram (page 47)
Fig. 30 · 4.7. Egg/Nest

Figure 4.10 Egg/Nest Configuration Page

Setting the Egg Login as Referred – Nologin allows the F3400/F1000 nest unit to access the F3400/F1000 egg without a password. If password protection is desired, select Always login. The Egg Alternate IP Address is completed with the egg's internet/public IP address when the F3400/F1000 is behind a firewall or NAT (Network Address Translation). A NAT enables the local-area network (LAN) to use one set of IP addresses for internal traffic and a second set of addresses for external traffic.

4.8. Falcon Links

Falcon Digital Video Recorder (F1000) — 4.8. Falcon Links diagram (page 47)
Fig. 31 · 4.8. Falcon Links

Figure 4.11 Falcon Links Configuration Page

The Main Menu allows users to link to up to four other F3400/F1000 units. The F3400/F1000 Links page allows users to designate the IP Addresses of these additional F3400/F1000 units.

Page 48 of the Falcon Digital Video Recorder (F1000) user manual — 4.9. SNMP/SYSLOG
Page 48 · click to enlarge
Page 48

4.9. SNMP/SYSLOG

Falcon Digital Video Recorder (F1000) — 4.9. SNMP/SYSLOG diagram (page 48)
Fig. 32

Figure 4.12 SNMP/SYSLOG Configuration Page

Persistent V1,V2C-Traps: Enables the F3400/F1000 to issue continuous SNMP Traps until an alarm acknowledgement is received by the F3400/F1000 or until the alarming point returns to normal. The parameter is a user defined time interval that is set in minutes. Traps can be acknowledged from the Alarm Management page. The SNMP Traps do not include any delivery verification. A Persistent Trap setting of 5 or 10 minutes will trigger the F3400/F1000 to send the Trap on a regular interval in case the previous Trap did not reach the Network Management System (NMS). Typically, the NMS can be set to ignore duplicate Traps to prevent re-alarming at the NMS.

Analog Trap Type: Used for communication to a NMS via SNMP Traps. The default will add the Value, UOM (Unit of Measure), and the Label fields. If preferred, the F3400/F1000 can send only the label on analog Traps. This makes analog Traps the same format as digital Traps which may make parsing the Traps easier for the NMS.

Select SNMP Trap Type: Select SNMP V1-Trap, V2C-Trap, or V2C Inform based on individual network system configurations.

Max Inform Retries: Set options related to resending unacknowledged inform requests.

Communities: Identifies devices that receive SNMP Traps and/or Syslog messages from the F3400/F1000 and interacts with the F3400/F1000 over the network. To add a device to the Communities list, select a community number posted as “empty”. Enter the receiving device’s IP Address and a string that identifies the device. An IP Address of 0.0.0.0 in this field allows any device to access the F3400/F1000 through an MIB browser. Select “Write” if the device will have Read/Write network access. This allows the F3400/F1000 to be configured over the network. Select “Traps” if the device will receive Traps from the F3400/F1000. Select “Syslog” if the device will receive Syslog messages from the F3400/F1000.

Page 49 of the Falcon Digital Video Recorder (F1000) user manual — 4.10. Modbus Interface
Page 49 · click to enlarge
Page 49

4.10. Modbus Interface

Falcon Digital Video Recorder (F1000) — 4.10. Modbus Interface diagram (page 49)
Fig. 33 · 4.10. Modbus Interface

Figure 4.13 Modbus Interface Configuration

The Modbus Interface page allows users to configure Modbus features for RLE products and enable Modbus slave capabilities for the unit.

Modbus/TCP Slave Unit Identifier: Enables and sets the slave unit address for Modbus over TCP/IP.

Modbus/RTU EIA-485 Slave Unit Identifier: Enables and sets the slave unit address for Modbus over EIA-485, twisted-pair wire. Disabling the slave unit identifier for RTU will enable the unit to act as a master over EIA-485, twisted-pair wire.

Serial Baud Rate: Sets the EIA-485 COM2 port to 1200, 2400 or 9600 Baud.

EIA-485 DE TX Delay: Normally left at the 10ms default and is active only when the Serial Interface Type is “EIA485”. During the start of transmission, the transmit line is driven high for this amount of time prior to transmitting the message. The time is adjustable from 10ms to 50ms.

EIA-485 DE Off Delay: Normally left at the default of 10ms and is active only when the Serial Interface Type is “EIA485”. After a message is sent, the transmit line is held high for this amount of time prior to turning off. The time is adjustable from 10 to 500ms.

Page 50 of the Falcon Digital Video Recorder (F1000) user manual — 4.10.1 LD Unit Modbus Slave Configuration
Page 50 · click to enlarge
Page 50

Modbus Master Poll Timeout: Sets the amount of time the F3400/F1000 waits for a response from the Slave device before moving on to read the next register. It is normally set to the default of 1. It is adjustable from 1 to 10 seconds.

Modbus Master Poll Interval: Sets the amount of time from when a response is received from a Slave to when the F3400/F1000 will ask for the next register and is adjustable from 250 to 2000ms. It is normally left at the 250ms default. The interval affects the overall scan rate. If the F3400/F1000 is configured to read 60 Modbus variables and the poll interval is set to 1000ms (1second), each Modbus variable will be read approximately once per minute.

Modbus Master Retry Attempts: Determines how many times the F3400/F1000 will request the same register when there is no response from the Slave before moving on to read the next register. It is normally left at the default of 1 second and is adjustable from 1 to 99.

LD Unit #1 Type - Unit #8: Select LD5000/LD5100/LD2000, LDRA6, or not installed.

4.10.1 LD Unit Modbus Slave Configuration

Falcon Digital Video Recorder (F1000) — 4.10.1 LD Unit Modbus Slave Configuration diagram (page 50)
Fig. 34 · 4.10.1 LD Unit Modbus Slave Configuration

Figure 4.14 LD Unit Modbus Slave Configuration

RTU Station Address: Enter the address of the Modbus Slave device. Be sure this matches the address programmed on the particular Slave device.

Description: Enter a description for the Slave device.

Dial Out Notification: Select the Phone Number Configuration Entry ID for up to four pager numbers to which the F3400/F1000 will send notification when any alarm for this Slave occurs. The Entry ID numbers correspond to phone numbers configured from the Configure Phone Number links at the bottom of the Modem Configuration page.

Example: If the Alarm dial out string is set to “3, 5, 1, 0”, the F3400/F1000 will dial Pager #1, Pager #3 and then Pager #5 when an alarm occurs.

Page 51 of the Falcon Digital Video Recorder (F1000) user manual — 4.10.3 Modbus Packet Log
Page 51 · click to enlarge
Page 51

Email Recipient Notification: Select the recipient email addresses that require notification when any alarm occurs on this Slave. The email addresses correspond to the email addresses configured from the Email Configuration page.

4.10.2 Modbus Register Data Log

This link allows users to view the raw data the F3400/F1000 receives from the Slave(s).

Column 1= F3400/F1000 Modbus Master Register Number. Column 2= Time the Data is Received. Column 3= Number of Bytes Reserved for Data. Column 4= Slave Data in Decimal Form.

Falcon Digital Video Recorder (F1000) — 4.10.2 Modbus Register Data Log diagram (page 51)
Fig. 35 · 4.10.2 Modbus Register Data Log

Figure 4.15 Modbus Register Data Log Page

4.10.3 Modbus Packet Log

This link displays a log of the Modbus packets that the F3400/F1000 is sending and receiving.

Falcon Digital Video Recorder (F1000) — 4.10.3 Modbus Packet Log diagram (page 51)
Fig. 36 · 4.10.3 Modbus Packet Log

Figure 4.16 Modbus Packet Log

Page 52 of the Falcon Digital Video Recorder (F1000) user manual — 4.10.5 F-Series Modbus Slave Register Map
Page 52 · click to enlarge
Page 52

Column 1 = System Up Time. Column 2 = Modbus Master Register Number. Column 3 = Direction of Packet: OUT = Packet Sent from the F3400/F1000 (Master Request). Column 4 = Modbus Packet.

4.10.4 Reset Modbus Port

This link allows users to reset the Modbus port so that the contents of the polling registers will be cleared.

4.10.5 F-Series Modbus Slave Register Map

Table 4.1 Output Registers

40001-40032 Input #1-32 Value 0-65535

40188-40193 MAC Address 0-65535

40194-40197 IP Address 0-65535

40198 Model No. 0-65535

40199 Firmware Version 0-65535

40200 Number of Alarms Present 0-65535

40201-40232 Input #1-32 Alarm Bitmap See Table 4.2

40401-40432 Input #1-32 Configuration See Table 4.3

Table 4.2 Status Flags (Registers 40201-40232)

00 1 = High1 Alarm

01 1 = Low1 Alarm

02 1 = High2 Alarm

03 1 = Low2 Alarm

04 1 = Digital Alarm

Table 4.3 Status Flags (Registers 40401-40432)

Show 7 more labels / short text on this page
Register Description Range · 40033-40187 Reserved · 40233-40400 Reserved · Bit Description · Integer Description · 0 Not Installed · 1 Not Configured
Page 53 of the Falcon Digital Video Recorder (F1000) user manual — 4.11. BACnet
Page 53 · click to enlarge
Page 53

Table 4.3 Status Flags (Registers 40401-40432) (continued)

4.11. BACnet

Falcon Digital Video Recorder (F1000) — 4.11. BACnet diagram (page 53)
Fig. 37 · 4.11. BACnet

Figure 4.17 BACnet Configuration

BACnet Device Name, BACnet Device ID and BACnet Description, BACnet UDP Port: Required for the F3400/F1000 to allow a Building Management System (BMS) to poll the F3400/F1000’s inputs using the BACnet protocol over LAN connections. For further information regarding BACnet Device Name, BACnet Device ID and BACnet Description, consult the BACnet Standard or your IT Department.

Show 7 more labels / short text on this page
Integer Description · 2 Analog 4-20mA · 3 Digital NO · 4 Digital NC · 5 Digital Status · 4-9 Reserved · 10 Thermistor
Page 54 of the Falcon Digital Video Recorder (F1000) user manual — 4.12. Server Ping
Page 54 · click to enlarge
Page 54

4.12. Server Ping

Falcon Digital Video Recorder (F1000) — 4.12. Server Ping diagram (page 54)
Fig. 38 · 4.12. Server Ping

Figure 4.18 Server Ping Configuration

The Server Ping page allows a user to monitor up to 16 devices by pinging at set intervals.

Ping Interval (Minutes): The time in minutes the F3400/F1000 will take to request time updates from the selected device(s). This can be set from 1-999. Enter 0 to disable.

Ping Retries: The amount of tries to establish communication with a device before entering an alarm state.

Dial Out Notification: The list of up to four pager numbers to which the F3400/F1000 sends alarm notification. The numbers correspond to phone numbers configured from the Configure Phone Number links at the bottom of the Modem Configuration page.

Email Recipient Notification: Allow up to four email addresses to be designated for notification if the input goes into alarm. Email addresses will be displayed once they are entered on the Email Configuration page. Email notification will be sent when a device alarms and when the device returns to normal.

Page 55 of the Falcon Digital Video Recorder (F1000) user manual — 4.13. System
Page 55 · click to enlarge
Page 55

4.13. System

Falcon Digital Video Recorder (F1000) — 4.13. System diagram (page 55)
Fig. 39 · 4.13. System

Figure 4.19 System Configuration

The System link allows users to configure basic F3400/F1000 information. The F3400/F1000's IP Address and Point-to-Point Protocol may also be configured through this menu, via the IP Configuration Menu link.

System Name: Appears on the F3400/F1000's Main Menu. The system name is also included as part of email and pager notifications.

System Contact: Lists the individual responsible for the F3400/F1000. The System Contact is only available through SNMP Gets and is not included in email, pager or SNMP Trap notifications.

System Location: Lists the location of the F3400/F1000. It is used to help identify the F3400/ F1000 when viewing the webpages. The System Location is not included in email, pager or SNMP Trap notifications.

Web Refresh Rate: The rate at which the F3400/F1000's webpages refresh themselves within the Web browser. Only pages that display monitoring points are automatically refreshed (Main Menu, Relay Status, View Points, and Modbus Slave pages). The default is 0 seconds (disabled), but is typically set for 15 to 20 seconds.

TFTP Server Enable (udp port: 69): This setting opens or closes Port 69 on the LAN connection to the F3400/F1000. The TFTP port is used to upgrade firmware and save and load configurations. It can be disabled for security reasons and only opened for short periods of time during firmware upgrades; see Chapter 8, “Upgrading Firmware and Managing Configuration Data” on page 73, for more information.

Digital Status Color: Allows you to choose the color (green, gold, magenta) displayed on the main menu.

Page 56 of the Falcon Digital Video Recorder (F1000) user manual — 4.15. Internet Protocol
Page 56 · click to enlarge
Page 56

4.14. Clock

Falcon Digital Video Recorder (F1000) — 4.14. Clock diagram (page 56)
Fig. 40 · 4.14. Clock

Figure 4.20 Clock Configuration

The Clock page allows users to set the date and time on the F3400/F1000's internal clock.

Enter the date using a MM/DD/YY format, where MM is a two digit month, DD is a two

digit day, and YY is a two digit year.

Enter the time using a HH:MM:SS format, where HH is a two digit hour, MM is a two digit

minute, and SS is a two digit second.

4.15. Internet Protocol

Falcon Digital Video Recorder (F1000) — 4.15. Internet Protocol diagram (page 56)
Fig. 41 · 4.15. Internet Protocol

Figure 4.21 Setting the Internet Protocol

The IP Configuration link found on the System Configuration page allows users to change a variety of settings, including the F3400/F1000's IP Address (used in PPP), Default Router and Subnet Mask. Contact a network administrator to obtain a valid IP Address for the network. Then, type the appropriate IP Address, Subnet Mask, and Default Router into the interface.

PPP Server: Sets the IP Address of the F3400/F1000’s network connection when accessing the F3400/F1000 via its internal modem. This is required to allow a remote PC to view the F3400/ F1000’s webpages over a dial-up connection. See Chapter 7, “Point-to-Point Protocol” on page 71, for more information.

PPP Assignment: Sets the IP Address of the remote PC's network connection when accessing the F3400/F1000 via its internal modem. This is required to allow a remote PC to view the

Page 57 of the Falcon Digital Video Recorder (F1000) user manual — 4.16. User Administration (Web Access)
Page 57 · click to enlarge
Page 57

F3400/F1000’s webpages over a dial-up connection. The remote PC’s dial-up settings should be set to “Obtain an IP Address Automatically”.

4.16. User Administration (Web Access)

Falcon Digital Video Recorder (F1000) — 4.16. User Administration (Web Access) diagram (page 57)
Fig. 42 · 4.16. User Administration (Web Access)

Figure 4.22 User Administration Configuration

The User Administration (Web Access) page allows the administrator to configure eight separate accounts, usernames, passwords and privileges for Web access accounts.

Read-Only privileges allow the user to view the Main Menu page, Keypad Access History,

Alarm History, Event History, Digital Data History, Identity, Relay Status, Relay Control and URL Links pages. The Configuration page cannot be viewed or changed by a Read-Only user. A Read-Only user can acknowledge alarms by entering their acknowledge code at the bottom of the Alarm History page. A Read-Only user can activate button controlled relay outputs through the Relay Control page. A Read-Only user cannot change any settings.

Read-Write privileges allow the user to have full access to all pages (viewing and changing)

except the User Administration (Web Access) page shown above.

Administrator privileges allow the user to have full access to all pages including the User

Administration (Web Access) page shown above.

Page 58 of the Falcon Digital Video Recorder (F1000) user manual — 4.17. Email
Page 58 · click to enlarge
Page 58

4.17. Email

Falcon Digital Video Recorder (F1000) — 4.17. Email diagram (page 58)
Fig. 43 · 4.17. Email

Figure 4.23 Email Configuration

The Email page allows users to configure the F3400/F1000 to send notification via email when inputs are in an alarm state. The F3400/F1000 will send one email message per alarm instance to a maximum of four email recipients.

Access Type: Specifies whether to send the message through a local network or over a PPP dial-up connection.

DNS Servers: Information provided by your ISP needed to deliver the email message.

Mail (SMTP) Server: Specifies the email server used to receive and send mail.

Mail Sender Address: The address displayed in the “From” field of the email message.

Mail Subject: Displayed in the subject field of the received email messages. Adding &m inserts the MAC Address of the F3400/F1000 into the email subject line. This ensures the email subject is always unique to a F3400/F1000.

Mail Recipient (1) - Mail Recipient (4): Enter the addresses of up to four email recipients.

SMTP Authentication: Used for ESMTP; use the recommended default setting unless instructed differently by your IT Department.

SMTP User Name: Used for ESMTP; use the recommended default setting unless instructed differently by your IT Department.

Page 59 of the Falcon Digital Video Recorder (F1000) user manual — 4.18. Network Time Protocol
Page 59 · click to enlarge
Page 59

SMTP Password: Used for ESMTP; use the recommended default setting unless instructed differently by your IT Department.

DUN User Name and Password: Only used if PPP is selected. The DUN Username and password specifies the dial-up network user name and password. Contact your ISP for this information.

DUN Phone Number: The number the F3400/F1000 dials to connect to the ISP. Contact your IT Department to obtain this phone number.

4.18. Network Time Protocol

Falcon Digital Video Recorder (F1000) — 4.18. Network Time Protocol diagram (page 59)
Fig. 44 · 4.18. Network Time Protocol

Figure 4.24 Network Time Protocol Configuration

Network Time Protocol (NTP) is widely used in the Internet to synchronize computer clocks to national standard time or Coordinated Universal Time (UTC). It synchronizes the time of a computer or server (in this case, the F3400/F1000) to another server or reference time source. NTP is important in maintaining a high level of accuracy and reliability in time-stamped events. This page allows users to configure the F3400/F1000’s NTP feature.

Network Time (NTP) Server: The IP address or hostname of the Network Time Protocol Server with which the F3400/F1000 will synchronize. Examples of public NTP Servers include “us.pool.ntp.org” and “time.nist.gov”.

Update Interval: The time in minutes the F3400/F1000 will take to request time updates from the NTP Server. This can be set from 5-1440 minutes. Enter 0 to disable.

Retry Interval: The time in seconds the F3400/F1000 waits before retrying a failed connection to the NTP Server. This can be set from 10-120 seconds.

Select Time Zone: Enter the time zone in which the F3400/F1000 resides.

Daylight Savings Time: Select the hour Daylight Savings Time occurs. Typically, this is 2:00 A.M. local time.

Page 60 of the Falcon Digital Video Recorder (F1000) user manual — 4.20. Flash Program
Page 60 · click to enlarge
Page 60

DST Begin Date: Enter the date Daylight Savings Time will begin.

DST End Date: Enter the date Daylight Savings Time will end.

4.19. Network Statistics

Falcon Digital Video Recorder (F1000) — 4.19. Network Statistics diagram (page 60)
Fig. 45 · 4.19. Network Statistics

Figure 4.25 Setting the Network Statistics

The Network Statistics page displays network and EIA485 statistics including: network packets received, packets transmitted, and errors.

4.20. Flash Program

Falcon Digital Video Recorder (F1000) — 4.20. Flash Program diagram (page 60)
Fig. 46 · 4.20. Flash Program

Figure 4.26 Flash Programs

The Flash Program link displays which versions of F3400/F1000 firmware are loaded onto the F3400/F1000. Only two copies can be loaded onto the F3400/F1000 at a time. In order to upload a Firmware update, the backup Flash must be blank. If it is not, click the Erase Backup button to erase it. This erases the oldest version of firmware stored on the F3400/F1000. See Chapter 8, “Upgrading Firmware and Managing Configuration Data” on page 73.

Using a TFTP client software program, send the F3400 (vx.x bx).bin file to the IP address of the F3400/F1000. The F3400/F1000 verifies the file name starts with F3400 and ends with .bin. Other file names or types will not be accepted. The F3400/F1000 will accept TFTP block sizes of 64, 128, 256, 512, or 1024. Once the program has been successfully uploaded, the F3400/

Page 61 of the Falcon Digital Video Recorder (F1000) user manual — 4.21. Product Registration
Page 61 · click to enlarge
Page 61

F1000 will automatically reboot. See Chapter 8, “Upgrading Firmware and Managing Configuration Data” on page 73, for more detailed instructions.

4.21. Product Registration

Falcon Digital Video Recorder (F1000) — 4.21. Product Registration diagram (page 61)
Fig. 47 · 4.21. Product Registration

Figure 4.27 Product Registration Located at www.rletech.com

The Product Registration link allows users to register their F3400/F1000 with RLE at the time of configuration. The F3400/F1000's IP Address, Subnet Masks, and Default Gateway must be configured before this link will be operational. Once configured, complete the registration form, and click the Register button to submit your information to RLE.

Page 62 of the Falcon Digital Video Recorder (F1000) user manual — Notes:
Page 62 · click to enlarge
Page 62

Notes:

Page 63 of the Falcon Digital Video Recorder (F1000) user manual — C H A P T E R
Page 63 · click to enlarge
Page 63

C H A P T E R

C HAPTER 0 EIA-232 I NTERFACE

The F3400/F1000’s EIA-232 interface provides a more detailed and intricate view of the F3400/F1000. It also allows a user to access more elaborate configuration options.

In order to proceed through this chapter, the F3400/F1000 must be connected to a PC via the EIA232 port. If the F3400/F1000 is not yet connected to a PC, connect the F3400/F1000's EIA232 COM1 port as follows:

1 Connect the EIA232 port on the F3400/F1000 to a terminal or PC running terminal emulation software (HyperTerminal) with a 9-pin male-female straight through serial cable (a serial cable is supplied with the F3400/F1000).

Falcon Digital Video Recorder (F1000) — C H A P T E R diagram (page 63)
Fig. 48

Figure 5.1 HyperTerminal Connection Screen

Page 64 of the Falcon Digital Video Recorder (F1000) user manual — 5.2. Flash Executable Code
Page 64 · click to enlarge
Page 64

2 Set the appropriate COM Port to 9600 baud, NO parity, 8 data bits, 1 stop bit, (9600/N/8/ 1), and no software or hardware flow control.

Falcon Digital Video Recorder (F1000) — 5.1. Unit Start Up diagram (page 64)
Fig. 49 · 5.1. Unit Start Up

Figure 5.2 Com1 Properties Screen

3 Once the terminal emulation software starts, press Enter on the keyboard and the Main Menu should appear. If the Main Menu does not appear, check the communication settings and make sure the unit is powered on.

5.1. Unit Start Up

When the unit is powered up, diagnostic tests are performed and the Flash Program code is verified. The main system code is executed after a 10 second delay. During the boot up sequence, the System Status LED will flash at a rapid rate of 10 flashes per second. If the System Status LED continues to flash for more then twenty seconds, there is a fault with the unit and service is required.

5.2. Flash Executable Code

After the bootup sequence, the main program executes from Flash memory. In order to run properly, the unit must have a unique MAC address (assigned by the manufacturer) and an IP address. The factory default for the IP address is 10.0.0.186. If the unit is connected to the enterprise’s network, an IP address must be obtained from the network administrator. The F3400/F1000 must be reconfigured with this new IP address. This reconfiguration can be done in the field. See the Configuration Menu, menu number 1. Once the system reaches this point, press Enter to display the System Main Menu.

5 EIA-232 Interface

Page 65 of the Falcon Digital Video Recorder (F1000) user manual — W ARNING
Page 65 · click to enlarge
Page 65

5.3. Main Menu

All system functions begin in the Main Menu. Two letter commands display information, execute commands and display submenus for additional inquiry and system configuration functions.

Table 5.1 Main Menu Commands

CA Current Alarms CA displays all active alarms on the master unit. If alarms are present, the System Status LED is red.

KA Kill Alarms KA acknowledges all alarms and terminates all dial-out communications and network Traps.

TI Display Date/ Time

TI displays the F3400/F1000's current time and date.

AD ADC Input Values

AD allows the user to examine the readings of the 4-20mA inputs. These readings can be referenced during start-up to verify gain and offset calculations. Data displayed depends on the expansion card(s) installed.

MS provides a summary of all modem information.

NS displays network and EIA485 statistics including: network packets received, packets transmitted, and errors.

SC displays a submenu that lists all items for system setup and configuration.

DU Dump Network Packets

DU dumps the headers of all network packets received and sent. Only active until the next command is entered. This item is for network debugging only and is not normally enabled.

NT Network Trace NT displays troubleshooting messages during the processing of network packets. Only active until the next command is entered. Network Trace is for network troubleshooting only and is not normally enabled.

PING PING Allows user to PING another device on the network.

EX Exit to Bootloader

EX is used to enter the Bootloader command section. The unit will stop monitoring the inputs and allow firmware updates to be loaded. To restore normal operation after updating firmware, type run and press Enter on the keyboard, or power the unit off and back on again.

The Bootloader section is designed for experienced technicians or users responsible for maintaining the system. Exit immediately if you have not been trained in the use of the Bootloader commands. Contact RLE for more information regarding the commands in this section.

W ARNING

Show 5 more labels / short text on this page
5 EIA-232 Interface · Command Description Function · MS Modem Statistics · NS Network Statistics · SC Main Configuration
Page 66 of the Falcon Digital Video Recorder (F1000) user manual — 5.3.1 Main Configuration Menu – SC
Page 66 · click to enlarge
Page 66

5.3.1 Main Configuration Menu – SC

Typing SC at the command prompt on the Main Menu displays the Main Configuration Menu that lists all items for system setup and configuration. This menu may be password protected. If it is, the password must be entered when the SC menu selection is made. To enter the password, type SC, press the space bar once, and then type the appropriate password.

Table 5.2 Main Configuration Menu (SC) Commands

1 IP Configuration Menu

1displays the IP Configuration Menu.

2 Factory Menu 2displays the Factory Menu. This menu provides a means to change the MAC address and erase the user configuration stored in Flash memory. This area is password protected. If you are familiar with MAC assignments and configuring the F3400/F1000, contact RLE Technologies for the password to this menu. WARNING! Once you receive the password for this menu, you assume full responsibility for the system configuration and proper MAC addressing of the F3400/F1000.

3 Load/Save Configuration Data

3allows user configurations to be saved and reloaded onto other F3400/F1000s. Windows HyperTerminal application software may be used to perform the load/save functions. Before the configuration can be loaded onto other F3400/ F1000s, it must be checked for accuracy. Blank spaces or unwanted characters, such as the “Press <enter> to download the file” text, may be saved into the beginning of the configuration file. Open the file in notepad and examine the first few lines. Delete any characters that were accidentally embedded into the file.

4 allows the user to password protect the configuration section of the F3400/F1000 Firmware. The password can be any combination of 7 numbers and/or characters.

x Exit x exits the Main Configuration Menu and returns to the Main Menu.

5 EIA-232 Interface · Command Description Function · 4 Configuration Password

Page 67 of the Falcon Digital Video Recorder (F1000) user manual — 5.3.2 IP Configuration Menu
Page 67 · click to enlarge
Page 67

5.3.2 IP Configuration Menu

The IP Configuration Menu is accessed by typing a 1at the command prompt in the Main Configuration Menu. This menu is used to establish IP/TCP and PPP interaction with the network. The F3400/F1000 must be set up with an IP address, mask, and default router. These addresses can be obtained from your Network Administrator or IT Department. To enable the SNMP receiving stations (create communities), the F3400/F1000 MIB, provided on a diskette with every unit, must be loaded on a system(s) running a Network Operating System (NOS). This MIB is compiled through standard functions of the NOS. Consult with your Network Administrator for proper installation of the F3400/F1000 MIB on the NOS. Once the MIB is loaded, the F3400/F1000 can be discovered and configured over the network. For proper operation, the IP addresses configured in the F3400/F1000 communities must match the IP addresses on the receiving stations. Only the administrator's username/password may be changed from this menu. All other Web users must be changed via the Web interface.

Table 5.3 IP Configuration Menu Commands

i LAN IP Address Designates the LAN IP address.

m Net Mask Designates the Subnet Mask.

D Default Route Establishes the default IP address.

u Web Administrator Username

Edits the Web administrator username.

p Web Administrator Password

Edits the Web administrator password.

f Web Refresh Rate

Changes the Web refresh rate.

s PPP Server IP Address

Designates the PPP server IP address.

c PPP Client IP Address

Designates the PPP client IP address.

z Max Seg Size (TCP)

Establishes the maximum segment size.

Communities Communities are computers that receive SNMP Traps from the F3400/F1000 and interact with the F3400/F1000 over the network. To add a computer to the communities list, select a menu number posted as “empty.” Enter the receiving computer's IP address, the type of network access the machine will have (r – read, w – read/write, n – none), and whether the computer will receive Traps or not (y – yes, n – no). Separate each of these items with a space and press Enter when done. The newly configured community member will appear in the appropriate space in the community listing. Type delete to remove an existing community.

5 EIA-232 Interface · Command Description Function

Page 68 of the Falcon Digital Video Recorder (F1000) user manual — 5.3.2 IP Configuration Menu
Page 68 · click to enlarge
Page 68

Table 5.3 IP Configuration Menu Commands (continued)

q Quit DOES NOT save changes and returns user to the Main Menu.

x Exit & Save Saves changes and returns user to the Main Menu.

5 EIA-232 Interface · Command Description Function

Page 69 of the Falcon Digital Video Recorder (F1000) user manual — (2400/N/8/1)
Page 69 · click to enlarge
Page 69

C H A P T E R

C HAPTER 0 R EMOTE A CCESS

6.1. Remote Access Configuration (Modem Option)

The F3400/F1000 can be remotely accessed with any terminal emulation software package. To establish a proper dial-out session, set the appropriate modem port as follows:

33.6K baud

(2400/N/8/1)

No software or hardware flow control

Once the proper settings are made, dial the phone number assigned to the F3400/F1000. Once communication is established, press Enter. A logon prompt will appear on the screen. Type the login and press Enter; type the password and press Enter. The session will begin.

NO parity · 8 bits · 1 stop bit

Page 70 of the Falcon Digital Video Recorder (F1000) user manual — Remote Access
Page 70 · click to enlarge
Page 70

Type a question mark (?) to view the System Menu. To terminate the session, execute the command in the software package that disconnects the modem. The commands for accessing the system remotely are identical to the ones described earlier in this user guide. There is, however, a limited command set for remote access. The available commands are:

Current Alarms (CA)

Kill All Alarms (KA)

Display Date/Time (TI)

ADC Input Values (AD)

Modem Stats (MS)

System Configuration (SC)

System Configuration is limited to the System Configuration Menu section.

Pages can be acknowledged by phone number during a remote access session by entering aa followed by the alarm acknowledgement code for that phone number.

6 Remote Access

Page 71 of the Falcon Digital Video Recorder (F1000) user manual — 7.1. Configuring the F3400/F1000
Page 71 · click to enlarge
Page 71

C H A P T E R

C HAPTER 0 P OINT - TO -P OINT P ROTOCOL

Point-To-Point Protocol (PPP) is an alternate method that may be used to communicate with the F3400/F1000. PPP can only be used through a modem, over a phone line. The F3400/F1000 and the user’s computer must both be configured correctly in order for PPP to work.

7.1. Configuring the F3400/F1000

1 Access the F3400/F1000's Web interface.

2 Click the Configuration link. Enter the correct user name and password (if necessary).

3 From the Configuration Menu, click on the System link.

4 On the System Configuration page, click on the IP Configuration Menu link.

The IP Configuration page lists the IP addresses configured on the F3400/F1000. Both the PPP Server and PPP Assignment fields need to be completed in order for PPP to work.

PPP Server: Assigns an IP address to the F3400/F1000 for PPP communications. Any IP address may be used, as long as it is not in the same subnet as the F3400/F1000's primary IP address. A good example of an IP address to use is: 192.168.1.2. Use this address to view the F3400/F1000 Web interface through a browser when communicating with the F3400/F1000 through PPP.

PPP Assignment: Tells the F3400/F1000 what IP address to assign to the PC the user dials in from. Again, any IP address may be used, as long as it is in the same subnet as the PPP Server IP address. A good example of an IP address to use is: 192.168.1.3

Page 72 of the Falcon Digital Video Recorder (F1000) user manual — 7.2. Configuring the PC
Page 72 · click to enlarge
Page 72

7.2. Configuring the PC

Now the user is ready to configure the PC they will be dialing in from. These directions were written from a Windows XP machine. To configure the PC:

1 Click on Start, Control Panel, then Network and Internet Connections. Select Internet Options.

2 When the Internet Properties window appears, select the Connections tab at the top of the window and click on the Setup button to start the New Connection Wizard.

3 Click the Next button to begin the Wizard.

4 Select Connect to the Internet and click the Next button.

5 Select the Set up my connection manually button and click Next.

6 Select the Connect using a dial-up modem button and click Next.

7 Type “F3400/F1000” as the name of the ISP in the space provided and click Next.

8 Enter the phone number of the phone line that connects to the F3400/F1000. Click the Next button.

9 Enter the F3400/F1000’s Modem User name and Password—see 4.16., “User Administration (Web Access)” on page 57—and click Next.

10Add a shortcut to the desktop. Click the Finish button.

7 Point-to-Point Protocol

Page 73 of the Falcon Digital Video Recorder (F1000) user manual — 8.1. Upgrading F3400/F1000 Firmware
Page 73 · click to enlarge
Page 73

C H A P T E R

CHAPTER 0UPGRADING FIRMWARE AND MANAGING CONFIGURATION DATA

8.1. Upgrading F3400/F1000 Firmware

You can upgrade F3400/F1000 firmware using either the:

TFTP client EIA-232 interface

Follow the instructions for the method you want to use.

Page 74 of the Falcon Digital Video Recorder (F1000) user manual — 8.1.1 Upgrading F3400/F1000 Firmware via TFTP Client
Page 74 · click to enlarge
Page 74

8 Upgrading Firmware and Managing Configuration Data

8.1.1 Upgrading F3400/F1000 Firmware via TFTP Client

This is the preferred method. However, it does not work with a PPP connection.

1 Download the most recent version of firmware appropriate for your F3400/F1000 from the Documentation/Files section of the F-Series webpage at www.rletech.com Save it to the hard drive of your computer. Do not change the name of the file. The name of the file, as downloaded from the RLE website, must remain the same.

2 The F3400/F1000 can only accept one copy of firmware at a time. Before a new version can be uploaded, the oldest version must be deleted. To do this, access the Flash Program link on the Configuration menu of the F3400/F1000’s Web interface. Click the Erase Backup button to erase the oldest version of firmware. It will take approximately 10 seconds for the firmware to be erased. A confirmation screen will appear once the firmware has been erased.

3 Click the Back button on your browser to return to the Flash Program screen. Reload this page to ensure the oldest firmware has been erased. A Checksum value of FFFF tells you the oldest firmware has been completely erased.

4 Uploading firmware via TFTP requires a TFTP Client. It may be possible to download a free license TFTP Client from the Internet. Consult your IT department to determine a compatible client program.

5 Verify that your PC and the F3400/F1000 are on the same subnetwork (LAN).

6 Open your TFTP client. Configure the client as follows.

a Host = F3400/F1000 IP Address

b Port = 69

c Block Size = 64, 128, 256, 512, or 1024

7 Send or PUT the firmware file to the F3400/F1000. It may take ~10 seconds for the firmware upload to begin.

8 Reload the Flash Program Configuration page to ensure the new firmware has successfully loaded onto the F3400/F1000.

Page 75 of the Falcon Digital Video Recorder (F1000) user manual — 8.1.2 Updating F3400/F1000 Firmware via the EIA232 COM1 Port (X-Modem)
Page 75 · click to enlarge
Page 75

8 Upgrading Firmware and Managing Configuration Data

8.1.2 Updating F3400/F1000 Firmware via the EIA232 COM1 Port (X-Modem)

1 Connect to the F3400/F1000 using HyperTerminal. For instruction on how to do so, see our support document “Connect HyperTerminal” available on the Documentation/Files section of the F-Series webpage at www.rletech.com

2 Start firmware updates by either:

a Pressing any key after power-up when a 10 second window provides an opportunity to

abort the Flash Main Program, or

b Typing EX to exit to Bootloader once the Main Menu appears.

3 From the F3400/F1000 Boot prompt, type ? and press ENTER to see the list of available commands.

4 From the F3400/F1000 Boot prompt, type ID and press ENTER. Note which Flash has the lowest serial number. The Flash with the lowest serial number is the backup. The idea is to erase the backup, load the new version, which becomes the active Flash, then erase and load the other Flash.

5 From the F3400/F1000 Boot Prompt, erase the back up Flash program (the one with the lowest serial number) by typing ERASE PRGM1or ERASE PRGM2 followed by ENTER. After a second or so, the screen will update with an OK.

6 From the F3400/F1000 Boot prompt, type LOAD PRGM1 XMODEM or LOAD PRGM2 XMODEM followed by Enter. Select the same program that was erased.

7 From the HyperTerminal menu select Transfer -> Send File. Use the browse button to select the F3400/F1000 firmware file from the computer's directory. The file must be binary and have a .bin extension. Select the file and upload it using the 1K X-Modem protocol. Then click Send.

8 A transfer status screen will be displayed. The transfer time will take about 10 minutes. Once the transfer is complete, the transfer status window will automatically close. The HyperTerminal window will indicate that the upload is complete.

9 From the F3400/F1000 Boot prompt, type RUN or power down the F3400/F1000 and restart it to verify that the new Flash program runs.

10Press ENTER to display the F3400/F1000 Main Menu and repeat the steps above to erase and download to the other Flash program chip.

11Once the firmware upgrade is complete, disconnect the serial cable and close HyperTerminal.

Page 76 of the Falcon Digital Video Recorder (F1000) user manual — 8.2.2 Saving Configuration Data via EIA232 COM1 Port (XModem)
Page 76 · click to enlarge
Page 76

8 Upgrading Firmware and Managing Configuration Data

8.2. Loading/Saving F3400/F1000 Configuration Data

This menu allows user configurations to be saved and reloaded onto other F3400/F1000, or in the unlikely event the F3400/F1000 fails, a replacement F3400/F1000 can be quickly placed back in service after loading the saved configuration information. The configuration settings are saved to a binary file for backup purposes, which cannot currently be edited off line.

8.2.1 Saving Configuration Data via TFTP Client

1 Verify that your PC is connected to the F3400/F1000 over the LAN and that port 69 is open between your PC and the Falcon.

2 Open your TFTP client. Configure the client as follows.

a Host = F3400/F1000 IP Address

b Port = 69

c Block Size = 64, 128, 256, 512, or 1024

3 The file name of the configuration being saved must contain the .cfg extension.

4 Fetch or GET the file. After a few seconds, the TFTP software should indicate when it is complete.

5 Use Windows Explorer to verify that the files exist on the PC's hard drive. Copy the files to your desired file backup location.

8.2.2 Saving Configuration Data via EIA232 COM1 Port (XModem)

1 Before starting, make sure the HyperTerminal properties are set correctly to perform load/ save. Select the Properties Menu (under File) to establish a direct connection through an available COM Port. This port should be set to 9600 Baud, 8 Data bits, NO Parity, 1 Stop bit, and NO Flow control.

2 Select the Settings tab for additional changes. The parameters under the Settings tab should reflect what is shown below.

3 To save settings, go to the F3400/F1000 onto which the configuration will be saved. Log into the F3400/F1000 (COM1) through HyperTerminal (Terminal Emulation Program). Navigate to the Load/Save Configuration Data Menu under the Main Configuration Menu.

4 Select option 1 (Save XModem-1K) from the Load/Save Configuration Data Menu followed by the ENTER key. Then select the Transfer/Receive File from the menu at the top of the HyperTerminal screen.

5 Specify a name by which to save the file and select the 1K X-Modem receiving protocol. Then click on the Receive/Start button.

6 Wait until the download is completed and enter X to exit the Load/Save Configuration Menu.

Page 77 of the Falcon Digital Video Recorder (F1000) user manual — 8.2.4 Loading Configuration Data via EIA232 COM1 Port (X-Modem)
Page 77 · click to enlarge
Page 77

8 Upgrading Firmware and Managing Configuration Data

8.2.3 Loading Configuration Data via TFTP Client

Before the configuration can be loaded onto other F3400/F1000s, it must be checked for accuracy. Blank spaces or unwanted characters, such as the “Press <enter> to download the file” text, may be saved into the beginning of the configuration file. Open the file in Notepad and examine the first few lines. Delete any characters that were accidentally embedded into the file.

1 Verify that your PC is connected to the F3400/F1000 over the LAN and that port 69 is open between your PC and the Falcon.

2 Open your TFTP client. Configure the client as follows.

a Host = F3400/F1000 IP Address

b Port = 69

c Block Size = 64, 128, 256, 512, or 1024

3 The file name of the configuration being loaded must contain the .cfg extension.

4 Send or PUT the file. After a few seconds, the TFTP software should indicate when it is complete.

5 Configurations are now loaded onto the replacement F3400/F1000. View the Falcon webpages to verify that the configurations are as expected.

8.2.4 Loading Configuration Data via EIA232 COM1 Port (X-Modem)

Before the configuration can be loaded onto other F3400/F1000s, it must be checked for accuracy. Blank spaces or unwanted characters, such as the “Press <enter> to download the file” text, may be saved into the beginning of the configuration file. Open the file in notepad and examine the first few lines. Delete any characters that were accidentally embedded into the file.

1 To load settings, go to the F3400/F1000 onto which the configuration will be loaded. Log into the F3400/F1000 (COM1) through HyperTerminal (Terminal Emulation Program). Navigate to the Load/Save Configuration Data Menu under the Main Configuration Menu.

2 Select option 2 (Load Xmodem 1K) from the Load/Save Configuration Menu and press ENTER. Then select Transfer/Send File from the menu at the top of the HyperTerminal screen.

3 Select the 1K X-Modem protocol. Locate the correct configuration file under Filename (Browse), select Open, and then select the Send button.

4 Wait until the Upload is completed and enter X to exit the Load/Save Configuration Menu.

Page 78 of the Falcon Digital Video Recorder (F1000) user manual — Notes:
Page 78 · click to enlarge
Page 78

8 Upgrading Firmware and Managing Configuration Data

Notes:

Page 79 of the Falcon Digital Video Recorder (F1000) user manual — CURRENT
Page 79 · click to enlarge
Page 79

A P P E N D I X

C HAPTER 0 A NALOG I NPUT 4-20 M A R EFERENCE

C HART

Analog 4-20Ma Gain/Offset Conversion Formula:

Gain = Sensor Range (High Value - Low Value) / 4 Offset = Sensor Low Value - Gain

ExampleTH140 Humidity

Gain = (High Value (100) -Low Value (0)) / 4 = 25 Offset = (Sensor Low Value (0) - Gain (25)) = -25

Table A.1 Analog Input 4-20mA Reference Chart

RLE Product Number Transducer Type Range Gain Offset

TEMPERATURE

TH140 Temperature (Display in Deg F) 50°F - 95°F 11 39

Temperature (Display in Deg F 32°F - 122°F 22 11

Temperature (Display in Deg C) 10°C - 35°C 6 4

Temperature (Display in Deg C 0°C - 55°C 13 -13

Humidity 0% - 100% RH 25 -25

T120 Temperature (Display in Deg F) 50°F - 95°F 11 39

Temperature (Display in Deg F) 32°F - 122°F 22 11

Temperature (Display in Deg C) 10°C - 35°C 6 4

Temperature (Display in Deg C) 0°C - 50°C 13 -13

CURRENT

CT55 Current 0 - 5 Amps 0 - 55 Amps 1 13 -1 -13

Page 80 of the Falcon Digital Video Recorder (F1000) user manual — VOLTAGE
Page 80 · click to enlarge
Page 80

A Analog Input 4-20mA Reference Chart

Table A.1 Analog Input 4-20mA Reference Chart (continued)

RLE Product Number Transducer Type Range Gain Offset

CT20 Current 0 - 30 Amps 0 - 60 Amps 0 - 120 Amps

CT200 Current 0 - 20 Amps 0 - 200 Amps 5 50 -5 -50

CT300 Current 0 - 100 Amps 0 - 300 Amps 25 75 -25 -75

VOLTAGE

PT300 Voltage - Single Phase 0 - 300 VAC 75 -75

3PT300 Voltage - Three Phase 0 - 300 VAC 75 -75

PT600 Voltage - Single Phase 0 - 600 VAC 150 -150

3PT600 Voltage - Three Phase 0 - 600 VAC 150 -150

LD5100 Leak Detection 4-20mA Output (Calc. in ft/m) 0 - 1000ft / 305m 250 -250

0. 2500ft / 762m 625 -625
0. 5000ft / 1524m 1250 -1250

LD5000 Leak Detection 4-20mA Output (Calc. in ft/m) 0 - 500ft / 152m 143 -179

0. 1000ft / 305m 286 -357
0. 1500ft / 457m 429 -536
0. 2000ft / 610m 571 -714
0. 2500ft / 762m 714 -893
0. 3000ft / 914m 857 -1071
0. 3500ft / 1067m 1000 -1250
0. 4000ft / 1219m 1143 -1429
0. 4500ft / 1372m 1286 -1607
0. 5000ft / 1524m 1429 -1786
Show 4 more labels / short text on this page
7 15 30 · -7 -15 -30 · LD5100 4-20mA · LD5000 4-20mA
Page 81 of the Falcon Digital Video Recorder (F1000) user manual — A P P E N D I X
Page 81 · click to enlarge
Page 81

A P P E N D I X

C HAPTER 0 F3400/F1000 A CCESSORIES W IRING

The following figures show the typical wiring between the F3400/F1000 Monitoring System and other products offered by RLE Technologies.

Falcon Digital Video Recorder (F1000) — A P P E N D I X diagram (page 81)
Fig. 50

Figure B.1 T120D Temperature Sensors

Falcon Digital Video Recorder (F1000) — A P P E N D I X diagram (page 81)
Fig. 51

Figure B.2 TH140 & TH140D Temperature/Humidity Sensors

Page 82 of the Falcon Digital Video Recorder (F1000) user manual — F3400/F1000 Accessories Wiring
Page 82 · click to enlarge
Page 82

B F3400/F1000 Accessories Wiring

Falcon Digital Video Recorder (F1000) — F3400/F1000 Accessories Wiring diagram (page 82)
Fig. 52 · F3400/F1000 Accessories Wiring

Figure B.3 Dwyer Temperature/Humidity Sensors

Falcon Digital Video Recorder (F1000) — F3400/F1000 Accessories Wiring diagram (page 82)
Fig. 53 · F3400/F1000 Accessories Wiring

Figure B.4 BAPI Temperature/Humidity Sensor

Falcon Digital Video Recorder (F1000) — F3400/F1000 Accessories Wiring diagram (page 82)
Fig. 54 · F3400/F1000 Accessories Wiring

Figure B.5 SMK Smoke Detector, Photoelectric

Page 83 of the Falcon Digital Video Recorder (F1000) user manual — F3400/F1000 Accessories Wiring
Page 83 · click to enlarge
Page 83

B F3400/F1000 Accessories Wiring

Falcon Digital Video Recorder (F1000) — F3400/F1000 Accessories Wiring diagram (page 83)
Fig. 55 · F3400/F1000 Accessories Wiring

Figure B.6 HD150 & HD150-2 Gas Sensors

Falcon Digital Video Recorder (F1000) — F3400/F1000 Accessories Wiring diagram (page 83)
Fig. 56 · F3400/F1000 Accessories Wiring

Figure B.7 SD Spot Detectors

Falcon Digital Video Recorder (F1000) — F3400/F1000 Accessories Wiring diagram (page 83)
Fig. 57 · F3400/F1000 Accessories Wiring

Figure B.8 PFM Power Fail Monitor

Page 84 of the Falcon Digital Video Recorder (F1000) user manual — B.1. Configuring the SeaHawk LD5100 as an Analog
Page 84 · click to enlarge
Page 84

B F3400/F1000 Accessories Wiring

Falcon Digital Video Recorder (F1000) — B.1. Configuring the SeaHawk LD5100 as an Analog Input diagram (page 84)
Fig. 58 · B.1. Configuring the SeaHawk LD5100 as an Analog Inp…

Figure B.9 SeaHawk LD5100/LD2000 Distance Read Leak Detection (Dry Contact)

B.1. Configuring the SeaHawk LD5100 as an Analog

Input

The F3400/F1000 averages/filters the analog inputs. The LD5100 will output approx. 3.95mA when there is no leak. The LD5000 will output a value between 4mA and 20mA when there is a water leak. The low limit 1 and low limit 2 set points should be set to a 0 value. High limit 1 should be set to a value, in feet, that represents 4.0mA (1 foot). This allows the F3400/F1000 to alarm whenever there is a leak. The high limit 2 should be set to a value, in feet, that will control the internal relay, if needed for the application. The Cable Fault relay, from the LD5100 should be tied back into the F3400/F1000 to detect a fault with the 5100 controller/cable. The analog output is only used for a Leak alarm distance.

Falcon Digital Video Recorder (F1000) — B.1. Configuring the SeaHawk LD5100 as an Analog diagram (page 84)
Fig. 59 · B.1. Configuring the SeaHawk LD5100 as an Analog

Figure B.10SeaHawk LD5100 Distance Read Leak Detection (4-20mA)

Falcon Digital Video Recorder (F1000) — B.1. Configuring the SeaHawk LD5100 as an Analog diagram (page 84)
Fig. 60 · B.1. Configuring the SeaHawk LD5100 as an Analog

Figure B.11SeaHawk LDRA6, LD1000, and LD300 Leak Detection

Page 85 of the Falcon Digital Video Recorder (F1000) user manual — B.1. Configuring the SeaHawk LD5100 as an Analog Input
Page 85 · click to enlarge
Page 85

B F3400/F1000 Accessories Wiring

For assistance wiring the following F3400/F1000 accessories also offered by RLE, please contact our Technical Support Department at (970) 484-6510:

CT55 and CT200 Single Phase Current Sensor

CT300 and CT800 Single Phase Current Sensor

PT150 Single Phase Voltage Sensor

PT300 Three Phase Voltage Sensor

PT600 Three Phase Voltage Sensor

MDS Magnetic Door Sensor

PS-RC Relay Controlled Two Outlet Receptacle

MD3 Motion Sensor

Page 86 of the Falcon Digital Video Recorder (F1000) user manual — Notes:
Page 86 · click to enlarge
Page 86

B F3400/F1000 Accessories Wiring

Notes:

Page 87 of the Falcon Digital Video Recorder (F1000) user manual — A P P E N D I X
Page 87 · click to enlarge
Page 87

A P P E N D I X

C HAPTER 0 A LARM ID R EFERENCE T ABLES

C.1. Analog Tables

Table C.1 Analog Alarm ID Reference Tables, Inputs 1-4

1 High Limit 1 001

1 Low Limit 1 002

1 High Limit 2 003

1 Low Limit 2 004

2 High Limit 1 005

2 Low Limit 1 006

2 High Limit 2 007

2 Low Limit 2 008

3 High Limit 1 009

3 Low Limit 1 010

3 High Limit 2 011

3 Low Limit 2 012

4 High Limit 1 013

4 Low Limit 1 014

4 High Limit 2 015

4 Low Limit 2 016

Channel Condition ID

Page 88 of the Falcon Digital Video Recorder (F1000) user manual — C.2. Thermistor Tables
Page 88 · click to enlarge
Page 88

C Alarm ID Reference Tables

C.2. Thermistor Tables

Table C.2 Thermistor Alarm ID Reference Tables, Inputs 5-8

5 High Limit 1 017

5 Low Limit 1 018

5 High Limit 2 019

5 Low Limit 2 020

6 High Limit 1 021

6 Low Limit 1 022

6 High Limit 2 023

6 Low Limit 2 024

7 High Limit 1 025

7 Low Limit 1 026

7 High Limit 2 027

7 Low Limit 2 028

8 High Limit 1 029

8 Low Limit 1 030

8 High Limit 2 031

8 Low Limit 2 032

Channel Condition ID

Page 89 of the Falcon Digital Video Recorder (F1000) user manual — C.3. Digital Tables
Page 89 · click to enlarge
Page 89

C Alarm ID Reference Tables

C.3. Digital Tables

Table C.3 Digital Alarm ID Reference Tables, Digital Inputs 5 through 32

Show 29 more labels / short text on this page
Channel Condition ID · 5 On/Off 085 · 6 On/Off 086 · 7 On/Off 087 · 8 On/Off 088 · 9 On/Off 089 · 10 On/Off 090 · 11 On/Off 091 · 12 On/Off 092 · 13 On/Off 093 · 14 On/Off 094 · 15 On/Off 095 · 16 On/Off 096 · 17 On/Off 097 · 18 On/Off 098 · 19 On/Off 099 · 20 On/Off 100 · 21 On/Off 101 · 22 On/Off 102 · 23 On/Off 103 · 24 On/Off 104 · 25 On/Off 105 · 26 On/Off 106 · 27 On/Off 107 · 28 On/Off 108 · 29 On/Off 109 · 30 On/Off 110 · 31 On/Off 111 · 32 On/Off 112
Page 90 of the Falcon Digital Video Recorder (F1000) user manual — Notes:
Page 90 · click to enlarge
Page 90

C Alarm ID Reference Tables

Notes:

Page 91 of the Falcon Digital Video Recorder (F1000) user manual — A P P E N D I X
Page 91 · click to enlarge
Page 91

A P P E N D I X

C HAPTER 0 T ECHNICAL S PECIFICATIONS

Table D.1 Technical Specifications

Power 24VDC Model24VDC (±10%), 600mA max., wall adaptor included

F1000 4 Configurable as 4-20mA (12-bit A/D conversion), 4 as Digital Input or Thermistor

F3400 4 Configurable as 4-20mA (12-bit A/D conversion), 4 as Digital Input or Thermistor and 24 Digital Input (

Ethernet 10BASE-T, RJ45 connector; 500VAC RMS isolation

EIA-232 DB9 female connector; 9600 baud; 3000VAC RMS optically isolated; 15kV ESD protection

EIA-485 (selectable as EIA232) Two-wire half duplex; terminal block (selecting EIA232 switches to DB9 male connector); 9600 baud; 3000VAC RMS optically isolated

Modem (RJ11 Telco) – Optional V.34bis/33.6 kbps; PPP-Enabled; FCC Part 68 approved; 1500VAC RMS isolation barrier; 2100V peak surge protection; (Modem optional)

Inputs · Analog/Digital · Communications Ports

Page 92 of the Falcon Digital Video Recorder (F1000) user manual — Technical Specifications
Page 92 · click to enlarge
Page 92

Table D.1 Technical Specifications (continued)

TCP/IP; UDP/IP; ICMP/IP; FTP; NTP; Telnet

IPv4.0; up to 5 URL links to other IP addressable cameras/ devices; webpages comply with Rehabilitation Act of 1973, sections 504 and 508, US Dept of Education (website accessibility for computer users with disabilities)

HTTP/HTML V1; MIB-2 compliant; NMS Manageable with Get, Set, and Traps; V2c- Traps or Informs.

SNMP Supports Client Authentication (plain and login); compatible with ESMTP Servers

SMTP (Email) Slave; RTU Mode; Supports function codes 03, 04, 06 and 16

Modbus RTU transmission protocol; function codes: Slave - 03; master - 01,02,03,04

Modus/IP Modbus Slave; TCP/IP transmission protocol

BACnet/IP Conformance Level 1

Terminal Emulation VT100 compatible

TAP (Pager) Telocator Alphanumeric Protocol Ver1.8

Pager (Modem) 4 Text, numeric and/or alphanumeric pager numbers; each Digital and Analog Alarm (HighLimit2 and LowLimit2) can notify any 4 of the 4 pagers

Email (Ethernet, Modem PPP) 4 Email recipients; email sent on Alarm and Return To Normal; each Alarm can notify any or all of the 4 email recipients

SNMP Traps (Ethernet) 8 Community Strings

Escalation Additional notification to 1 of the 4 pager numbers when initial page results in Failure To Acknowledge status

Real Time Clock Battery backed; ±1.53 min/month accuracy

Memory 512K RAM; 128K NVRAM; 64K ROM; 2M Flash

Alarm Log Last 100 Alarms

Event Log Last 100 Events (e.g., Acknowledgement By Code, System Boot, Page Successful, etc.)

Web User Access Log Last 100 HTML Accesses (User, Date, and Time)

Digital Status Log Last 100 Digital Status entries

Trending of Analog Inputs 244 Entries per time frame, per channel

Minute Every minute, high/low/avg for the last 65 minutes

Hour Every hour, high/low/avg for the last 25 hours

Day Every day, high/low/avg for the last 7 days

Show 5 more labels / short text on this page
D Technical Specifications · Protocols · Alarm Notification · Internal Hardware · Logging Capabilities
Page 93 of the Falcon Digital Video Recorder (F1000) user manual — Technical Specifications
Page 93 · click to enlarge
Page 93

Table D.1 Technical Specifications (continued)

Web Browser Access (Ethernet, Modem PPP)

1 Administrator plus 7 Users individually selectable for Read Only, Read/Write or Administrator

Terminal Emulation Access (Modem, EIA232)

1 Administrator (password for both Modem and EIA232) plus 1 Read Only; (password for Modem only, not EIA232)

Switches Power1 (on/off)

LED Indicators Power: 1 green (on/off); Status: 1 red (flashing = boot-up, on = alarm, off = normal); Network Link: 1 green; Network Activity: 1 green; Modem: 4 green (transmit, receive, off hook and carrier detect)

Temperature 32° to 158°F (0° to 70°C)

Humidity 5% to 95% RH, non-condensing

Altitude 15,000ft (4,572m) max.

Storage Environment -40º to 185ºF (-40º to 85ºC)

Dimensions 16.8"W x 1.8"H x 7.9"D (427mmW x 46mmH x 201mmD)

Weight 6 lbs. (2.72kg)

Mounting Rack mount, or wall mount (brackets required): WMB wall mount brackets (not included)

Certifications CE; ETL listed: conforms to UL STD 61010-1, EN STD 61010-1; CSA C22.2 STD NO. 1010-1; RoHS compliant

Show 4 more labels / short text on this page
D Technical Specifications · Login Security · Front Panel Interface · Operating Environment
Page 94 of the Falcon Digital Video Recorder (F1000) user manual — Notes:
Page 94 · click to enlarge
Page 94

Notes:

D Technical Specifications

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Display codes

Error codes

What the fault codes shown on the display mean and how to clear them.

CodeMeaningFix
F1000Access the F3400/F1000 through a Web browser by typing the IP address into the p.21

Ask about the Falcon Digital Video Recorder (F1000)

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Falcon Digital Video Recorder (F1000)

Be the first to ask — other owners or our team will answer.

Original document

Falcon Digital Video Recorder (F1000) manual PDF

94 pages·1.8 MB·Digital Video Recorder·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…