Genie
GigE Vision Area Scan Camera
Series
Camera User’s Manual
M640
M1024
M1400
M1600



© 2007 DALSA All information provided in this manual is believed to be accurate and reliable. No responsibility is assumed by DALSA for its use. DALSA reserves the right to make changes to this information without notice. Reproduction of this manual in whole or in part, by any means, is prohibited without prior permission having been obtained from DALSA. Microsoft is a registered trademark; Windows®, Windows 2000®, and Windows XP®, are trademarks of Microsoft Corporation. All other trademarks or intellectual property mentioned herein belong to their respective owners. June 20, 2007, Document Number: CA-GENM-MUM00 *CA-GENM-MUM00*
About DALSA DALSA is an international high performance semiconductor and electronics company that designs, develops, manufactures, and markets digital imaging products and solutions, in addition to providing wafer foundry services. DALSA Digital Imaging offers the widest range of machine vision components in the world. From industry-leading image sensors through powerful and sophisticated cameras, frame grabbers, vision processors and software to easy- to-use vision appliances and custom vision modules. DALSA is a public company listed on the Toronto Stock Exchange under the symbol “DSA”. Based in Waterloo, ON, Canada, the company has operations in Montreal, QC; Bromont, QC; Colorado Springs, CO; Eindhoven, NL; Munich, Germany and Tokyo, Japan.





Description
The Genie monochrome camera family form a series of affordable, easy to use digital cameras specifically engineered for industrial imaging applications. Genie cameras combine standard gigabit Ethernet technology with the DALSA Trigger-to-Image-Reliability framework to dependably capture and transfer images from the camera to the host PC.
All Genie cameras are supported by DALSA Sapera™ LT software libraries featuring CamExpert for simplified camera set-up and configuration. Sapera LT is field proven in thousands of robust industrial applications. Hardware independent, Sapera LT delivers the same reliable performance regardless of the image acquisition device being used. This unique feature allows OEM’s to start using the Genie without re-writing applications developed for DALSA frame grabbers. In addition, Sapera LT includes powerful diagnostics and setup utilities for application development, custom camera configurations and system deployment.
Genie Monochrome Series-GigE Vision Camera Genie Monochrome Series Overview • 5

6 • Genie Monochrome Series Overview Genie Monochrome Series-GigE Vision Camera

This manual covers the five monochrome Genie models summarized below. See "Camera Performance Specifications" on page 8 for each Genie model.
Camera Sensor Size Resolution Pixel size (µm) fps (full frame)
Genie M640-1/2 1/2 in 640 x 480 9.9 x 9.9 64 CR-GEN0-M6400
Genie M640-1/3 1/3 in 640 x 480 7.4 x 7.4 64 CR-GEN3-M6400
Genie M1024 1/3 in 1024 x 768 4.65 x 4.65 20 CR-GEN0-M1020
Genie M1400 1/2 in 1360 x 1024 4.65 x 4.65 15 CR-GEN0-M1400
Genie M1600 1/1.8 in 1600 x 1200 4.40 x 4.40 12 CR-GEN0-M1600
Genie Framework composed of the Sapera network Imaging Package, Genie Imaging Driver and latest Genie Firmware.
Included with Genie and required
Sapera Runtime including CamExpert Included and installed if desired
GenICam™ support (XML camera description file) Embedded within Genie
Sapera LT version 6.00 or later (sold separately):
Provides everything you will need to develop imaging applications Sapera documentation in compiled HTML help, and Adobe Acrobat® (PDF) formats
Sapera Processing Imaging Development Library (sold separately): Includes over 600 optimized image processing routines.
Contact Sales at DALSA
Genie Cables & Accessories (sold separately) Product number
Genie I/O and Power breakout cable (Hirose to Euroconnector) CA-GENC-IOP00
Tripod mount bracket (mount to Genie top or bottom—provides ¼-20 socket) CA-GENA-BRA00
Industrial type CAT 6 cable assembly: Molded shroud with top/bottom thumbscrews on one end with standard Ethernet RJ45 clip on other. Available in various lengths. See "Ruggedized RJ45 Ethernet Cables" on page 97.
Genie Monochrome Series-GigE Vision Camera Genie Monochrome Series Overview • 7
Product Number · Software Product Number

Specifications for each available sensor are listed after the general Genie camera specifications.
Synchronization Modes Free running and Triggered Synchronous and Reset mode Software trigger (through Ethernet)
Exposure Modes Programmable (1µs granularity) Pulse controlled
Trigger Input Opto-isolated, 2V to 12V typical, 2mA min. Debounce range from 1 µs up to 255 µs
LUT 8-bit / 10-bit
Flip Real-time horizontal flip
Binning Horizontal (2 pixel) and Vertical (2 line)
Timestamp 1µs internal timer to timestamp images and events
Test image Internal pattern generator
User settings Select factory default or one user camera configuration
Back Focal Distance—C mount 17.52 mm
Camera Size 29(H) x 44(W) x 67(L) in mm, ( see Mechanical Specifications )
Mass < 125g (no lens)
Power connector 12 pin male Hirose
Input Voltage +11 to +13 Volts DC, ( over voltage–reverse voltage protected )
Power Dissipation < 4W
Operating Temperature 0 to 45°C
Output Data Configuration Gigabit Ethernet (IEEE 802.3)
Data and Control GigE Vision compliant at 1000 or 100 Mbps
8 • Genie Monochrome Series Overview Genie Monochrome Series-GigE Vision Camera


Genie cameras are 100% compliant with the GigE Vision 1.0 specification which defines the communication interface protocol used by any GigE Vision device. For more information see: http://www.machinevisiononline.org/public/articles/index.cfm?cat=167
Genie cameras implement a superset of the GenICam™ specification which defines device capabilities. This description takes the form of an XML device description file respecting the syntax defined by the GenApi module of the GenICam™ specification. For more information see www.genicam.org

Each sensor description below provides a specification table and response graphic. The graph describes the sensor response to different wavelengths of light (excluding lens and light source characteristics). Visible light spans wavelengths between about 390 - 780 nanometers. Wavelengths below 390 nm are termed ultra-violet while those above 780 nm. are termed infra-red. The peak response is around 500 nanometers typical for each sensor model, corresponding to a shade of blue-green.
Genie Monochrome Series-GigE Vision Camera Genie Monochrome Series Overview • 9

Item / Feature Specification
Imager Format Full frame interline CCD area scan with square pixel
Resolution 640 x 480 pixels
Minimum Frame Rate (free-running) 0.1 fps (one frame every 10 seconds)
Maximum Frame Rate (free-running) 64 fps
Maximum Exposure 1 / frame rate - 100μs
Pixel Size 9.9µm x 9.9µm
Pixel Format 8-bit, 10-bit
Shutter Full frame electronic shutter
Gain Range -6dB to +12dB

10 • Genie Monochrome Series Overview Genie Monochrome Series-GigE Vision Camera
Sensor Sony ICX414AL

Item / Feature Specification
Imager Format Full frame interline CCD area scan with square pixel
Resolution 640 x 480 pixels
Minimum Frame Rate (free-running) 0.1 fps (one frame every 10 seconds)
Maximum Frame Rate (free-running) 64 fps
Maximum Exposure 1 / frame rate - 100μs
Pixel Size 7.4µm x 7.4µm
Pixel Format 8-bit, 10-bit
Shutter Full frame electronic shutter
Gain Range -6dB to +12dB

Genie Monochrome Series-GigE Vision Camera Genie Monochrome Series Overview • 11
Sensor Sony ICX424AL

Item / Feature Specification
Imager Format Full frame interline CCD area scan with square pixel
Resolution 1024 x 768 pixels
Minimum Frame Rate (free-running) 0.1 fps (one frame every 10 seconds)
Maximum Frame Rate (free-running) 20 fps
Maximum Exposure 1 / frame rate - 100μs
Pixel Size 4.65μm (H) × 4.65μm (V)
Pixel Format 8-bit, 10-bit
Shutter Full frame electronic shutter
Gain Range -6dB to +12dB

12 • Genie Monochrome Series Overview Genie Monochrome Series-GigE Vision Camera
Sensor Sony ICX204AL

Item / Feature Specification
Imager Format Full frame interline CCD area scan with square pixel
Resolution 1360 x 1024 pixels
Minimum Frame Rate (free-running) 0.1 fps (one frame every 10 seconds)
Maximum Frame Rate (free-running) 15 fps
Maximum Exposure 1 / frame rate - 100μs
Pixel Size 4.65µm (H) x 4.65µm (V)
Pixel Format 8-bit, 10-bit
Shutter Full frame electronic shutter
Gain Range -6dB to +12dB

Genie Monochrome Series-GigE Vision Camera Genie Monochrome Series Overview • 13
Sensor ICX267AL

Item / Feature Specification
Imager Format Full frame interline CCD area scan with square pixel
Resolution 1600 x 1200 pixels
Minimum Frame Rate (free-running) 0.1 fps (one frame every 10 seconds)
Maximum Frame Rate (free-running) 12 fps
Maximum Exposure 1 / frame rate - 100μs
Pixel Size 4.40μm (H) × 4.40μm (V)
Pixel Format 8-bit, 10-bit
Shutter Full frame electronic shutter
Gain Range -6dB to +12dB

14 • Genie Monochrome Series Overview Genie Monochrome Series-GigE Vision Camera
Sensor Sony ICX274AL

Sapera LT is a powerful development library for image acquisition and control. Sapera LT provides a single API across current and future DALSA hardware. Sapera LT delivers a comprehensive feature set including program portability, versatile camera controls, flexible display functionality and management, plus easy to use application development wizards.
Sapera Processing is a comprehensive set of C++ classes for image processing and analysis. Sapera Processing offers highly optimized tools for image processing, blob analysis, search (pattern recognition), OCR and barcode decoding.
The following is a Sapera application functional block diagram.
Genie Framework
GVSP – GigE Vision Stream Protocol GVCP - GigE Vision Control Protocol
Ethernet
cable
GenICam Environment
Genie cameras implement the GenICam™ specification which define the device capabilities. The GenICam XML device description file is embedded within Genie firmware allowing GenICam applications to know Genie capabilities immediately after connection. For more information about the GenApi module of the GenICam™ specification see www.genicam.org
Genie Monochrome Series-GigE Vision Camera Genie Monochrome Series Overview • 15

16 • Genie Monochrome Series Overview Genie Monochrome Series-GigE Vision Camera

Warning! (Grounding Instructions)
Static electricity can damage electronic components. Please discharge any static electrical charge by touching a grounded surface, such as the metal computer chassis, before performing any hardware installation.
If you do not feel comfortable performing the installation, please consult a qualified technician.
If the computer to be used with the Genie camera does not have a Gigabit network adapter or second built in Gigabit NIC, a PCI bus Gigabit NIC needs to be installed. Typically under Windows XP the PCI Gigabit NIC is recognized automatically when Windows boots. An example of a high performance NIC is the Intel PRO/1000 MT adapter.
Review the NIC documentation concerning any special driver required for Windows. Install the PCI bus Gigabit NIC as described by the NIC manufacture's documentation.
The Genie camera has been tested with a variety of Gigabit network adapters, both built into the system motherboard and as third party PCI adapters.
The Genie obtains an IP address using the Link Local Address (LLA) or DHCP, by default. If required, a persistent IP address can be assigned (see "Running the Network Configuration Tool" on page 26).
The LLA method automatically assigns the Genie with a randomly chosen address on the 169.254.xxx.xxx subnet. After an address is chosen, the link-local process sends an ARP query with that IP onto the network to see if it is already in use. If there is no response, the IP is assigned to the device, otherwise another IP is selected, and the ARP is repeated. Note that LLA is unable to forward packets across routers.
Alternatively, if a DHCP server is present on the network, the Genie is going to issue a DHCP request asking for an IP address. The DHCP server will then provide the Genie an IP address.
Examples where a Gigabit Ethernet switch would be used are:
In these cases the Ethernet switch is a transparent device. The device discovery process finds all Genie cameras, and presents them as ready to be controlled by an application such as CamExpert.
Genie Monochrome Series-GigE Vision Camera Installing the Genie Camera • 17

An Ethernet switch supporting VLAN (Virtual Local Area Network) allows multiple isolated subnets to exist on the same switch.
Within each VLAN group, the Genie camera and controlling computer will behave identically as if connected to a simple Ethernet switch. But each VLAN group is isolated from each other, Therefore a Genie in one VLAN group is never seen by a computer on a different VLAN group.
VLAN Ethernet Switches support configuration as Port-based or TAG VLAN groups. Port-based groups are typically easier to configure. Review your Ethernet switch manual for information on its factory default VLAN settings and configuration method.
The Genie camera installation generally follows the sequence described below. Detailed installation instructions follow this overview.
18 • Installing the Genie Camera Genie Monochrome Series-GigE Vision Camera

When Sapera application development is performed on the same computer that the Genie is connected to, the Sapera Development Library (version 6.0 or later) must be installed. Else, Sapera LT is not required to control the Genie camera.
Refer to Sapera LT User’s Manual concerning application development with Sapera.
Genie Monochrome Series-GigE Vision Camera Installing the Genie Camera • 19

The Genie Framework software package and Sapera runtime provides all components required to control the Genie with the supplied CamExpert tool. Genie Framework software components include the Network Imaging driver, the Sapera GigE server, and CamExpert (if Sapera LT library is not installed).
After a successful Genie software package installation, the GigE Server icon is visible in the desktop taskbar tray area. The Genie camera must be on the same subnet as the NIC to be recognized by the GigE Server.
Device Available Device IP Error Device Not Available
GigE Server Tray Icon:
The GigE server tray icon when the Genie device is found. It will take a few seconds for the GigE Server to refresh its state after the Genie has obtained an IP address.
The GigE server tray icon shows a warning when a device is connected but there is some type of IP error.
A red X will remain over the GigE server tray icon when the Genie device is not found. This indicates a major network issue.
If you place your mouse cursor on this icon, the GigE Server will display the number of GigE Vision devices found by your PC. Right click the icon and select status to view information about those devices. See "Running the Network Configuration Tool" on page 26 and "Troubleshooting" on page 101for more information.
20 • Installing the Genie Camera Genie Monochrome Series-GigE Vision Camera

Connect a power supply to the Genie camera and an Ethernet cable from the Genie to the host computer. Once communication with the host computer is started the automatic IP configuration sequence will assign an LLA IP address as described in section "Genie IP Configuration Sequence" on page 23, or a DHCP IP address if a DHCP server is present on your network. The factory defaults for Genie is Persistent IP disabled and DHCP enabled with LLA always enabled as per the GigE Vision specification. For additional information see "IP Configuration Mode Details" on page 77. See the next section "Connectors" on page 21 for an overview of the Genie interfaces.
The Genie has only two connectors:
The Genie has one multicolor LED to provide a simple visible indication of camera state (see figure below and section "Status LED Codes" on page 22). Additionally the RJ45 has two LEDs for network status conditions.
The following figure of the Genie back end shows connector and LED locations. See "Mechanical Specifications" on page 89 for details on the Genie connectors and camera mounting dimensions.

Genie – Rear View
Genie Monochrome Series-GigE Vision Camera Installing the Genie Camera • 21

The camera is equipped with a LED to display the operational status of the camera. When more than one condition is active, the LED color indicates the condition with the highest priority (such as an acquisition in progress has more priority than a valid IP address assignment). The following table summarizes the LED states and corresponding camera status.
LED is off No power to the camera
Steady Red Camera not initialized
Slow Flashing Red Camera initialization problem
Fast Flashing Red Camera is too hot
Slow Flashing Blue Waiting for an IP address
Fast Flashing Blue Ethernet cable disconnected (no link)
Steady Blue IP address assigned; no application connected to the camera
Steady Green Application connected
Slow Flashing Green Triggered acquisition in progress
Fast Flashing Green Free-running acquisition in progress
Once the Genie has its RJ45 connected to a network, the Status LED will turn to steady blue when the IP address is assigned. Only at this time will it be possible by the GigE Server or any application to communicate with the camera.
22 • Installing the Genie Camera Genie Monochrome Series-GigE Vision Camera
LED State Definition

The following LED sequence occurs when the Genie is powered up connected to a network with installed Genie Framework software.
Blue IP assigned Green application
The Genie IP (Internet Protocol) Configuration sequence to assign an IP address is executed automatically on camera power-up or when connected to a network. As a GigE Vision compliant device, Genie attempts to assign an IP address as follows.
For any GigE Vision device, the IP configuration protocol sequence is:
The factory defaults for Genie is Persistent IP disabled and DHCP enabled with LLA always enabled as per the GigE Vision specification. For additional information see "IP Configuration Mode Details" on page 77.
Once the Genie is assigned an IP address (its Status LED is steady blue) the GigE server tray icon will not have a red X through it, indicating that the Genie device was found. It might take a few seconds for the GigE Server to refresh its state after the Genie has obtained an IP address.
Right-click the GigE Server tray icon to open the following menu.

Click on Status to open a window listing all devices connected to the host system. Each GigE device is listed by name along with important information such as the assigned IP address and device MAC address. The screen shot below shows a connected Genie with no networking problems.

Genie Monochrome Series-GigE Vision Camera Installing the Genie Camera • 23

In the event that the device is physically connected, but the Sapera GigE Server icon is indicating that the connected device is not recognized, click Scan Network to restart the discovery process. Note that the GigE server periodically scans the network automatically to refresh its state. See "Troubleshooting" on page 101 for network problems.
Most Gigabit network interface controllers (NIC) allow user modifications to parameters such as Adapter Buffers and Jumbo Frames. These should be optimized for use with the Genie during the installation.
Adapter Buffers (receive descriptors): Under certain conditions the host PC system CPU may be very busy with tasks other than the imaging application. Incoming image packets remain in the PC memory allocated to store packets instead of immediately being copied into the image buffer. By increasing the NIC host buffers, more incoming image packets can be stored by the NIC before it must start discarding them. This provides more time for the PC to switch tasks and move image packets to the image buffer.
Not all network boards allow increasing their buffer count and even among those that do, such as the Intel NIC, different versions will have different maximum receive descriptor values. Refer to the NIC user documentation for details on configuring this parameter. The procedure in this section shows how to increase the number of packet buffers for one version of Intel network adapter.
Jumbo Frames: With good gigabit Ethernet connections with minimal packet resend conditions, host computer performance can be further improved by increasing the data packet size. Each streaming video packet causes an interrupt in the host computer. Therefore increasing the packet size reduces the CPU usage percentage required to handle video data from Genie.
Before the Genie is configured to use larger data packets, the NIC used with the Genie must be configured to allow Jumbo Frames. The procedure in this section describes increasing the size of Jumbo Frames for one version of Intel network adapter.
The screenshot below shows that the Genie device was found and there is no IP conflict. The Maximum Packet Size field is highlighted in yellow, indicating that Jumbo Frames are not enabled on the NIC used with the Genie or that the control application is forcing a safe packet size. Using a larger packet size improves host CPU performance, which can be critical when using multiple Genie devices. Note that the Maximum Packet Size field is updated only when an application such as CamExpert communicates with the Genie.

24 • Installing the Genie Camera Genie Monochrome Series-GigE Vision Camera



GigE NIC Receive Buffers
Genie Monochrome Series-GigE Vision Camera Installing the Genie Camera • 25
GigE NIC Configuration


GigE NIC Jumbo Frames
Once the GigE Server discovers a device, start the Network Configuration tool to verify and modify the network configuration of the imaging system. See "Network Configuration Tool" on page 79.

First verify the Genie camera appears as a child of the NIC card it is connected to. By default the Genie camera is identified by its serial number if no user-defined name has been assigned.
Because image transfers require considerable bandwidth through the NIC, it is recommended that a separate Gigabit Ethernet NIC for the Genie camera be used. Connections to the Internet or to a corporate network should be through a different NIC.
26 • Installing the Genie Camera Genie Monochrome Series-GigE Vision Camera

The Network Configuration Tools allows you to:
The Genie firmware may need to be updated to correspond with the currently used Genie software framework. After installing the new Genie software package and Genie camera, update the firmware by following this procedure.

Genie Monochrome Series-GigE Vision Camera Installing the Genie Camera • 27


28 • Installing the Genie Camera Genie Monochrome Series-GigE Vision Camera

When the Genie camera is directly connected to a Gigabit network adapter on a host computer or via a network switch, testing the installation with CamExpert is a straightforward procedure.

Genie Monochrome Series-GigE Vision Camera Installing the Genie Camera • 29

The Genie can be programmed with a user-defined name to aid identifying multiple cameras connected to the network. For instance, on an inspection system with 4 cameras, the first camera might be labeled “top view”, the second “left view”, the third “right view” and the last one “bottom view”. The factory default user name is set to match the camera serial number for quick initial identification. Note that the factory programmed Genie serial number and MAC address are not user changeable.
When using CamExpert, multiple Genie cameras on the network are seen as different "Genie_M640_x" devices. Click on a Genie device user name to select it for control by CamExpert.
An imaging application uses any one of these attributes to identify a camera: its IP address, MAC address, serial number or User Name. Some important considerations are listed below.
30 • Installing the Genie Camera Genie Monochrome Series-GigE Vision Camera

Camera and Sensor Information
Camera and sensor information can be retrieved via a controlling application. Parameters such as camera model, firmware version, sensor characteristics, etc. are read to uniquely identify the connected Genie device.
All these features, with the exception of the DeviceUserId, are read-only. Sapera LT or GenICam calls are used to retrieve this information and correctly identify the camera along with its characteristics.
Following is an overview of CamExpert displaying this information followed by tables with the feature name associated to Sapera LT and to GenICam development environments.
The Camera Information Parameters tab groups parameters that contain information specific to the individual Genie camera.

Genie Monochrome Series-GigE Vision Camera Operational Reference • 31

Device Vendor For the Genie Monochrome series, this is always DALSA.
Device Model Name Displays the device model name (for example, Genie M640).
Device Version Displays the device version.
Firmware Version Displays the currently loaded firmware version.
Device ID Displays the camera serial number.
MAC Address Displays the unique MAC (Media Access Control) address of the Genie camera.
Device User ID Specifies a user written ID, of up to 15 characters, for the Genie camera. By default, this field is set to the serial number of the camera.
Power-up Configuration Click Setting to open the Power-up configuration dialog box which allows you to specify camera power-up configuration. For more information, see "Power-up Configuration" on page 32.
The Power-up configuration dialog allows you to specify the camera configuration to load when powering-up the camera. The Genie camera flash memory contains two possible configuration settings; the Factory Default, and a user-defined Camera Configuration 1. The Camera Power-up configuration drop-down list box allows you to select either the Factory Default or a user specified camera configuration file. To save the current CamExpert settings to the camera user-defined (Camera Configuration) setting, click Save. To view in CamExpert a camera configuration file currently saved in the camera, select the configuration file in the Load configuration from Camera drop-down list, and click Load. See "Genie Power-up Configuration" on page 67 for a list of the saved parameters.

32 • Operational Reference Genie Monochrome Series-GigE Vision Camera
Parameter Description · Parameter Description

Genie Sapera parameters for Camera and Sensor Information:
Interface = {GigE Vision} DeviceVendorName = “DALSA” DeviceModelName = “Genie M640” for Genie M640 DeviceVersion = String representing the version of the camera FirmwareVersion = String representing the version of the camera firmware DeviceID = String representing the camera serial number MACAddress = String representing the camera MAC address DeviceUserID = String representing the user-define name for the camera DeviceMaxThroughput = Maximum throughput of image streaming in bytes/sec. DeviceScanType = {Areascan} ColorType = {Monochrome Sensor} SensorWidth = Width of the sensor in pixels SensorHeight = Height of the sensor in lines PixelSize = Number of bits per pixel
In CamExpert, these parameters are visible under “Camera Information” and “Sensor” tabs. See "Accessing Features with Sapera++ LT" on page 68.
GenICam features for Camera and Sensor Information:
DeviceVendorName = Name of camera vendor DeviceModelName = Name of the camera model DeviceVersion = Version of the device DeviceFirmwareVersion = Version of camera firmware DeviceID = Serial number of the camera DeviceUserID = User-defined name the camera DeviceScanType = {Areascan} DeviceMaxThroughput = Maximum number of bytes per second device supports DeviceRegistersStreamingStart = Announces the start of registers streaming without immediate checking for consistency DeviceRegistersStreamingEnd = Announces the end of registers streaming and perform validation for registers consistency before activating them DeviceRegistersCheck = Performs an explicit register set validation for consistency DeviceRegistersValid = Informs whether the current register set is valid and consistent SensorWidth = Width of sensor (effective pixels) SensorHeight = Height of sensor (effective pixels) WidthMax = Maximum image width. Depends on binning and decimation HeightMax = Maximum image height. Depends on binning and decimation
Genie Monochrome Series-GigE Vision Camera Operational Reference • 33

Genie provides a number of sensor controls to optimize image acquisitions for most imaging solutions. Following is an overview of the CamExpert controls displaying this information, followed by individual control function descriptions and tables indicating the feature name associated to Sapera LT and to GenICam development environments.
The Sensor Parameters tab groups the parameters related to the camera sensor configuration for acquisition.

Device Scan Type Displays the device scan type. Possible values are area scan or linescan. This is always area scan for Genie.
Color Type Displays the color type of the sensor. Possible values are Color Sensor or Monochrome Sensor.
Sensor Width (in pixels) Displays the sensor width (in pixels).
Sensor Height (in pixels) Displays the sensor height (in pixels).
34 • Operational Reference Genie Monochrome Series-GigE Vision Camera
Parameter Description

Frame Rate (in Hz) Specifies the internal trigger frame rate for free run mode, in Hz. Possible values range from 0.1 to 64.0 Hz for Genie M640 in full scan mode. (Note: the Sapera SDK specifies the frame rate in milliHertz). The maximum frame rate increases by using binning (see below) or partial scan (see "Partial Scan—Window ROI" on page 37).
Gain (in dB) Specifies the sensor analog Gain factor, in dB. Possible values range from –6.0 to 12.0 dB, in 0.1 dB increments. For more information, see "Gain and Black Level Controls" on page 36.
Black level (in 1/16 DN) Specifies the sensor black level, in 1/16 DN (digital number, which is the value assigned to a pixel in a digital image). Possible values range from -128 to 127.
Binning Horizontal Enables or disables horizontal binning. Possible values are Disabled or 2 pixels. When set to 2 pixels, the image buffer width parameter is automatically adjusted. For more information, see "Binning" on page 41.
Binning Vertical Enables or disables the vertical binning. Possible values are Disabled or 2 lines. When set to 2 lines, the image buffer height parameter is automatically adjusted. The maximum frame rate also increases.
Test Image Selector Specifies the test image. Possible values are:
Off Grey Horizontal Ramp Grey Vertical Ramp Grey Diagonal Ramp Moving Purity
For more information, see "Internal Image Test Patterns" on page 62.
Exposure Control Click Setting to open the Exposure Control dialog. For more information, see "Exposure Controls" on page 43.
Genie Monochrome Series-GigE Vision Camera Operational Reference • 35
Parameter Description

The Genie series of monochrome cameras provide gain and black level adjustments for the analog signal from each CCD pixel, before the analog to digital conversion. The software gain and black level controls can make small compensations to the acquisition in situations where lighting varies and the lens iris can not be easily adjusted. The user can evaluate Gain and Black Level by using CamExpert.
Features and limitations are described below.
( ) Offset Gain Exposure OutputData + = * ) log( 20 : multiplier Gain where =
Genie Sapera parameters for Gain and Black level:
Gain = Amplification in dB from -6.0 to 12.0 dB BlackLevel = DC offset in 1/16th of DN, range from -128 to 127
In CamExpert, these parameters are available under the “Sensor” tab. See "Accessing Features with Sapera++ LT" on page 68.
GenICam features for Gain and Black level:
GainRaw = Analog gain in tenth of dB (0.1 dB) BlackLevelRaw = Black level (offset) in 1/16 of DN
36 • Operational Reference Genie Monochrome Series-GigE Vision Camera

The Partial Scan mode, also know as vertical cropping, reduces the number of video lines grabbed for a frame. By not scanning the full vertical area of the sensor, the maximum possible acquisition frame rate is proportionately increased (as an extreme example, the M640 scanning a one line frame, exposed around 589fps).

M640 Maximum Frame Rate
M1024 Maximum Frame Rate
M1400 Maximum Frame Rate
1024 -- -- 15 fps
768 -- 20 fps 20 fps
512 -- 28 fps 27 fps
480 64 fps 30 fps 28 fps
240 115 fps 50 fps 42 fps
120 194 fps 74 fps 55 fps
60 293 fps 99 fps 66 fps
30 394 fps 118 fps 73 fps
1 589 fps 146 fps 81 fps
Genie Monochrome Series-GigE Vision Camera Operational Reference • 37

Genie also can crop the acquisition horizontally by grabbing less pixels on each horizontal line. Additionally a horizontal offset value will start the grab from any pixel count, as shown in the following figure. Note that horizontal cropping does not increase the maximum frame rate due to the CCD readout architecture.

Horizontal Scan offset Active Horizontal Scan
Vertical and Horizontal Cropping can be combined to grab only a region of interest (ROI). Besides eliminating post acquisition image cropping done by software in the host computer, a windowed ROI grab reduces the bandwidth required on the Gigabit Ethernet link since less pixels are transmitted. See "CamExpert Image Buffer and ROI Parameters" on page 40 to use CamExpert to configure image cropping.
38 • Operational Reference Genie Monochrome Series-GigE Vision Camera
Horizontal Crop

Genie Sapera parameters for Partial Scan and Window ROI:
Width = Buffer width in pixels Height = Buffer height in lines OffsetX = Horizontal Offset in pixels of the leftmost pixel relative to the sensor OffsetY = Vertical offset in lines of the uppermost pixel relative to the sensor PixelFormat = {Monochrome 8-bit, Monochrome 10-bit}
See "Accessing Features with Sapera++ LT" on page 68.
GenICam features for Partial Scan and Window ROI:
Width = Width of image/area of interest Height = Height of image/area of interest OffsetX = Left coordinate of area of interest OffsetY = Top coordinate of area of interest LinePitch = Distance between consecutive lines in bytes PixelColorFilter = Color filter convention of the image PixelFormat = Format of the image pixels as per GigE Vision specification PixelDynamicRangeMin = Minimum pixel value sent by camera PixelDynamicRangeMax = Maximum pixel value sent by camera
Genie Monochrome Series-GigE Vision Camera Operational Reference • 39

CamExpert provides controls to configure acquisitions via the Image Buffer and ROI Parameters tab. The image buffer can be easily cropped as desired. Below is the CamExpert dialog and parameter descriptions follow.

Pixel Format For the Genie Monochrome series, the image buffer format is Monochrome 8-bit or 10-bit.
Width (in Pixels) Displays the image buffer width (X axis), in pixels.
Height (in Pixels) Displays the image buffer height (Y axis), in pixels.
OffsetX (in Pixels) Specifies the offset in X, from the left of the image, when using an ROI. The image buffer width is automatically adjusted to compensate for this offset.
OffsetY (in Lines) Specifies the offset in Y, from the top of the image, when using an ROI. The image buffer height is automatically adjusted to compensate for this offset.
Image Flip Enables hardware based horizontal image flip.
40 • Operational Reference Genie Monochrome Series-GigE Vision Camera
Parameter Description

Binning is the process where the charge on two (or more) adjacent pixels is combined. This results in increased light sensitivity since there is twice the sensor area to capture photons. The sensor spatial resolution is reduced but the improved low-light sensitivity plus lower signal-noise ratio may solve a difficult imaging situation. The user can evaluate binning by using CamExpert.
Genie supports horizontal and vertical binning independently, by a factor of 2 in each axis. Specifically if horizontal binning only is activated, a nominal 640x480 image is reduced to 320x480. If vertical binning only is activated, the image is reduced to 640x240. With both binning modes activated, the resulting image is 320x240.
Vertical binning also provides an increase in maximum acquisition frame rate. The frame rate increase depends on the camera model and amount of vertical cropping used. The following graphic illustrates binning.
1 640 639 4 3 2
Repeated for each line of pixels
1 2 320 Horizontal Binning
Repeated for each column of pixels
Horizontal and Vertical Binning Illustration
Genie Monochrome Series-GigE Vision Camera Operational Reference • 41

Genie Sapera parameters for Binning:
BinningHorizontal = {Disabled = 1, 2 pixels = 2} BinningVertical = {Disabled = 1, 2 lines = 2}
In CamExpert, these parameters are available under the “Sensor” tab. See "Accessing Features with Sapera++ LT" on page 68.
GenICam features for Binning:
BinningHorizontal = Number of horizontally binned cells (1 = no binning) BinningVertical = Number of vertically binned cells (1 = no binning)
Genie image exposures are initiated by an event. The trigger event is either the camera's programmable internal clock used in free running mode, an external input used for synchronizing exposures to external triggers, or a programmed function call message by the controlling computer. These triggering modes are described below.
42 • Operational Reference Genie Monochrome Series-GigE Vision Camera

Exposure Control modes define the method and timing of how to control the sensor integration period. The integration period is the amount of time the sensor is exposed to incoming light before the video frame data is transmitted to the controlling computer.
Genie is in a multifunctional free running mode with the following features:

Free-running Programmable Exposure Timing
Genie Monochrome Series-GigE Vision Camera Operational Reference • 43


Programmable Synchronous Mode Exposure Timing

Programmable Reset Mode Exposure Timing
44 • Operational Reference Genie Monochrome Series-GigE Vision Camera


External Trigger Level-controlled Exposure Timing
Genie Sapera parameters for Exposure Control:
FrameRate = 0.1 Hz up to max. frame rate supported by sensor in current mode of operation. Only available with Trigger disabled. ExposureMode = {Programmable = 1, Pulse Controlled = 2} ExposureTime = Exposure duration in µs
In CamExpert, these parameters are available under “Sensor” tab. See "Accessing Features with Sapera++ LT" on page 68.
GenICam features for Exposure Control:
ExposureMode = {Off = 0, Timed = 1, TriggerWidth = 2, TriggerControlled = 3, ResetContinuous = 4} ExposureTimeRaw = Exposure duration in µs AcquisitionFrameRate = Controls the desired frame rate of the camera in mHz (0.001 Hz). Only available when trigger is disabled. AcquisitionFrameCount = Number of frames to be acquired in MultiFrame acquisition mode AcquisitionMode = {Continuous = 0, SingleFrame = 1, MultiFrame = 2} AcquisitionStart = Start image capture using currently selected acquistion mode AcquisitionStop = Stop image capture AcquisitionAbort = Abort image capture
Genie Monochrome Series-GigE Vision Camera Operational Reference • 45

Genie supports two types of sensor synchronization used to align the exposure to sensor timing:

Synchronous Mode Timing example for Genie M640
46 • Operational Reference Genie Monochrome Series-GigE Vision Camera


Reset Mode Timing example for Genie M640
Genie Sapera parameters for Synchronization Mode:
ExposureAlignment = {Synchronous = 0, Reset = 1}
In CamExpert, these parameters are available under the “Sensor” tab in the “Exposure Control” dialog box. See "Accessing Features with Sapera++ LT" on page 68.
GenICam features for Synchronization Mode:
SensorSynchronization = {Synchronous = 0, Reset = 1}
Genie Monochrome Series-GigE Vision Camera Operational Reference • 47

CamExpert groups the Genie I/O Controls Parameters in one group. These parameters allow configuring the Genie inputs and outputs for type of signal and signal polarity. The screen capture below shows the CamExpert I/O parameters dialog and is followed by a descriptive overview. Detailed information on inputs and outputs follow this section.

Trigger Enables or disables the Genie camera trigger.
Trigger Source Specifies the trigger source. Possible values are Software, Input 1, or Input 2. Note that this field is only available when the Trigger parameter is True.
Frames per Trigger Set the number of frames acquired per trigger – max. 64k (driver 1.10 limited to 1 frame).
Input Settings Click on Setting to open the Input Settings dialog box, which allows you to specify the trigger input settings. For more information, see "General Inputs: Settings Via CamExpert" on page 49.
Output Settings Click on Setting to open the Output Settings dialog box, which allows you to specify the trigger output settings. For more information, see "General Outputs: Settings via CamExpert" on page 51.
For more information on triggers, see "General Inputs" on page 49.
48 • Operational Reference Genie Monochrome Series-GigE Vision Camera
I/O Controls Dialog · Parameter Description

CamExpert provides control of inputs via the I/O Controls Parameters tab. The Input Settings dialog box allows you to view the signal and status for each pin on the Hirose connector. The Polarity drop-down list boxes, located in the INPUT Settings area, allow you to specify the polarity of the Input 1 and Input 2 as either Active High or Active Low. The Minimum duration field for each input, allows you to specify the minimum trigger length (1- 255µs ) so that input transitions are debounced to prevent unwanted trigger events.

Genie Monochrome Series-GigE Vision Camera Operational Reference • 49
Input Settings Dialog

Genie Sapera parameters for Trigger Modes and General Inputs:
TriggerDelayToIntegration = Delay in µs from trigger to exposure TriggerEnable = {FALSE, TRUE} TriggerSource = {Input 1 = 0, Input 2 = 1, Software = 2} TriggerSoftware = {FALSE, TRUE} FramesPerTrigger = Frame count 1 to 64k
PolarityInput_x = {Active High = 0, Active Low = 1} DebounceInput_x = debouncing period in µs (from 1 to 255 µs)
See "Accessing Features with Sapera++ LT" on page 68.
GenICam features for Trigger Modes and General Inputs:
TriggerMode = {Off = 0, On = 1} TriggerSelector = (not used) TriggerSoftware = Generates a software trigger to start the acquisition in software trigger mode TriggerSource = {Line2 = 1, Software = 2} TriggerActivation = {LevelLow = 0, LevelHigh = 1} TriggerDelayAbs = Absolute delay to apply in us after reception of the trigger signal before starting exposure
InputLineSelector = Index to general input {input1=0, input2=1} InputLinePolarity = {Active High = 0, Active Low = 1} InputLineDebouncingPeriod = debounce period in µs (from 1 to 255 µs) InputLineValue = Read input line state {low=0, high=1}
50 • Operational Reference Genie Monochrome Series-GigE Vision Camera

Genie provides two sets of opto-coupled outputs (see "External Outputs" on page 92). These can be used as a strobe signal to control lighting or to generate programmable pulses when specific events are generated by the camera. They can also be set to a static state (close or open) by the application.
See "12-Pin Hirose Connector Signal Details" on page 90 for connector pinout and electrical information.
The Output Settings dialog box allows you to configure the event mode for both output 1 and output 2. Each output can be set independently to one of the available event modes. A typical usage of output is to control a strobe light in relation to the camera exposure. Select the output to configure by clicking on the Output 1 or Output 2 buttons located at the top of the dialog box. Use the Event mode drop-down list box to select the required event mode.
The following event modes are available:
Genie Monochrome Series-GigE Vision Camera Operational Reference • 51

When an event mode is selected, its trigger output schematic or signal timing diagram is displayed, as well as any other additional parameters for the mode.
For most event modes, the trigger output signal can be set to either Active Open (that is high with the load connected to a voltage source) or Active Closed (where current is drawn through the load). The output delay can be set from 0 to 4 seconds, in increments of 1 µs. The pulse duration can be set from 100µs to 4 seconds, in increments of 1 µs.
You can open and close the output circuit using software rather than hardware events, to control external devices. To control the output setting with Sapera LT see "Output Control via Sapera LT or GenICam Applications" on page 56.


The Strobe On Start of Exposure event mode is used when controlling a strobe light using the Genie output pin. The exposure delay parameter is specified using the Sensor Parameters tab Exposure Control setting.
For Synchronous mode, the exposure start timing is aligned to the line period of the sensor. This can delay the start of exposure by an amount of up to 31.77µs for the Genie M640. For more information on exposure synchronous time see "Exposure Controls" on page 43.

52 • Operational Reference Genie Monochrome Series-GigE Vision Camera

The Pulse On Valid Trigger event mode generates an output signal when a valid input trigger is received.

This event mode generates an output signal when an invalid input trigger is received. An invalid trigger is any trigger received while the camera is engaged in frame acquisition (exposure and readout) and cannot accept trigger inputs. This is shown by the trigger exclusion region in the following diagram.

Genie Monochrome Series-GigE Vision Camera Operational Reference • 53

The Pulse On Start of Readout event mode generates an output signal when the camera begins a readout operation from the sensor.

The Pulse On End of Readout event mode generates an output signal when the camera finishes a readout operation from the sensor.

54 • Operational Reference Genie Monochrome Series-GigE Vision Camera

The Pulse On End of Acquisition event mode generates an output signal when the acquisition process is terminated using software.

The Pulse On Input 1 or Input 2 event modes generate an output signal when the specified input signal is asserted.

Genie Monochrome Series-GigE Vision Camera Operational Reference • 55

Genie Sapera parameters for Strobe and General Outputs. See "Accessing Features with Sapera++ LT" on page 68.
OutputSelectorOutput_x = {Open = 0, Close = 1, Strobe On: Start of Exposure = 2, Pulse On: Valid Trigger = 4, Pulse On: Invalid Trigger = 5, Pulse On: Start of Readout = 6, Pulse On: End of Readout = 7, Pulse On: End of Acquisition = 8, Pulse On: Input 1 = 9, Pulse On: Input 2 = 10} PulseDelayOutput_x = Delay in µs to assert pulse output PulseDurationOutput_x = Pulse duration in µs PolarityOutput_x = {Active Close = 0, Active Open = 1}
GenICam features for Strobe and General Outputs:
OutputLineSelector = Index to select output line {output 1 = 0, output 2 = 1} OutputLineMode = {SoftwareDriven = 0, EventDriven = 1} OutputLineEventSource = Event generating output line pulse {StartOfTrigger=0, StartOfExposure=1, EndOfExposure=2, StartOfReadout=3, EndOfReadout=4, EndOfAcquisition=5, EventOnInputLine1=6, EventOnInputLine2=7, OverTrigger=8, OutputLinePulsePolarity = State of output opto-coupler {Active Close = 0, Active Open = 1} OutputLinePulseDelay = Delay in µs to assert pulse output (range 0 to 64k) OutputLinePulseDuration = Pulse duration in µs (range 0 to 64k) OutputLineValue = static output state {Open = 0, Close = 1}
The Genie monochrome series of cameras support a number of functions to enhance acquisitions or perform real time processing. Functions can be combined to solve specific imaging situations. The user can enable and evaluate each operation by using CamExpert.
The Genie camera includes a user programmable LUT as a component of its embedded processing features. The LUT is used for operations such as gamma adjustments, invert and threshold processes. CamExpert has a number of built in LUT operations for the user to explore (see "CamExpert LUT Controls" on page 87).
For monochrome sensors, the LUT table is a single 8-bit or 10-bit LUT (8/10-bit in, 8/10-bit out) as illustrated in the following figure. Pixel data when read out of the sensor is passed through the LUT memory array, where the new programmed pixel value is then passed to the Genie output circuit. The LUT data table is stored along with other parameters with the user configuration function (see "Power-up Configuration" on page 32).
56 • Operational Reference Genie Monochrome Series-GigE Vision Camera

Simplified Genie LUT Block Diagram
Simplified 8-bit LUT Block Diagram
Genie Sapera parameters for LUT:
LUTEnable = {FALSE, TRUE} LUTFormat = {Mono 8, Mono 10 – Unsigned} LUTNumberEntries = Number of entries in the LUT (256 for an 8-bit LUT, 1024 for a 10-bit LUT) LUTData = Array of data representing the LUT content
Sapera++ classes used:
SapLut Class implements LUT management. SapAcquisition::GetLut to get a valid SapLut object. SapAcquisition::ApplyLut to program the SapLut object.
In CamExpert, these features are available from the “Pre-Processing” menu.
GenICam features for LUT:
Genie Monochrome Series-GigE Vision Camera Operational Reference • 57

Image Shading correction, also know as Flat Field Correction is the process of eliminating small gain differences between pixels in a sensor array. That sensor when exposed to a uniformly lit field will have no gray level differences between pixels when calibrated flat field correction is applied to the image. The Genie camera stores flat field correction data until power off or in its user setting state for recall at any time (see "Power-up Configuration" on page 32). Flat field correction data is composed of 8 bit gain and 8 bit offset coefficients.
The CamExpert Flat Field Correction tool allows calibrating. saving, and loading the flat field calibration data for any Genie camera being controlled.
Before performing calibration, verify Genie acquisition with a live grab. Also at this time make preparations to grab a flat light gray level image, required for the calibration, such as a clean evenly lighted white wall or non-glossy paper. Note the lens iris position for a white but not saturated image. Additionally check that the lens iris closes well or have a lens cover to grab the dark calibration image.
Calibration is the process of taking two reference images, one of a black field – one of a light gray field (not saturated), to generate correction data for images captured by Genie. Each sensor pixel data is modified by the correction factor generated by the calibration process, so that each pixel now has an identical response to the same illumination.
The Flat Field calibration window provides a three step process to acquire two reference images and then save the flat field correction data for the Genie used. To aid in determining if the reference images are valid, a histogram tool is provided so that the user can review the images used for the correction data.
58 • Operational Reference Genie Monochrome Series-GigE Vision Camera


CamExpert Flat Field Calibration Menu
Genie Monochrome Series-GigE Vision Camera Operational Reference • 59

Genie Sapera parameters for Flat Field Correction:
FlatFieldEnable = Enable Flat Field Correction {False=0, True=1} FlatFieldFormat = {RO: mono 8, mono 9, mono 10, RGB} FlatFieldWidth = read buffer width FlatFieldHeight = read buffer height FlatFieldGainMin = read minimum gain value FlatFieldGainMax = read maximum gain value FlatFieldOffsetMin = read minimum offset value FlatFieldOffsetMax = read maximum offset value FlatFieldGainBuffer = Flat Field correction gain data buffer FlatFieldOffsetBuffer = Flat Field correction offset data buffer
In CamExpert, these features are available from the “Pre-Processing” menu.
GenICam features for Flat Field Correction:
60 • Operational Reference Genie Monochrome Series-GigE Vision Camera
Not supported

The Genie supports a software controlled horizontal flip function as shown in the following figure. The process is done in hardware with no loss of acquisition frame rate.
As shown in the following figure, a vertical flip function is simply accomplished by mounting the Genie camera upside down and by programming the camera to do a horizontal flip. Genie provides identical mounting holes on both its top and bottom side to ease installations.
Mount Genie Upside Down Horizontal Flip
Genie Sapera parameter for Image Flip: ImageFlip = {disabled=0, horizontal=1}
In CamExpert, this feature is available in the Image Buffer menu. See "Accessing Features with Sapera++ LT" on page 68.
Genie Monochrome Series-GigE Vision Camera Operational Reference • 61
Horizontal Flip · Image Flip Illustrations · Not supported

The Genie camera includes a built in test pattern generator that can be used to confirm camera Ethernet connections or driver installations, without the need for a camera lens or proper lighting. The pattern generator inserts video just after the sensor A/D converter, therefore Genie processing such as the LUT act on the generator images or on sensor images.
CamExpert is used to easily enable and select the Genie test patterns. As shown in the following figure, select the Sensor tab, then select one of the four patterns from the drop menu. Select live grab to see the pattern output.

Genie Test Pattern Selection – on Sensor Tab


62 • Operational Reference Genie Monochrome Series-GigE Vision Camera

Genie Sapera parameters for Image Test Patterns:
TestImageSelector = {Off = 0, Grey Horizontal Ramp = 1, Grey Vertical Ramp = 2, Grey Diagonal Ramp Moving = 3, Purity = 4}
In CamExpert, these parameters are available in the “Sensor” tab. See "Accessing Features with Sapera++ LT" on page 68.
GenICam features for Image Test Patterns:
TestImageSelector = {Off = 0, HorizontalWedge = 1, VerticalWedge = 2, DiagonalMovingWedge = 3}
Genie supports a number of events that a control application can monitor. Events provide real time notification on various stages of the acquisition sequence and of error conditions. A Sapera application registers callbacks for those events that need monitoring.
Two types a callbacks can be registered for events when using the Genie:
Genie Monochrome Series-GigE Vision Camera Operational Reference • 63

Acquisition Device Event Name (case sensitive strings)
Start of Trigger Trigger is valid based on the programmed trigger parameters
Start of Exposure Exposure has started
End of Exposure Exposure is complete
Feature Value Changed Parameter value is changed
Feature Info Changed Configuration parameter is changed
Invalid Trigger Trigger event (software or external) was invalid
Input Event 0 External Input # 1 has received a valid signal
Input Event 1 External Input # 2 has received a valid signal
Output Event 0 External Output # 1 has changed state
Output Event 1 External Output # 2 has changed state
Transfer Event Name Description
End of frame transfer Video frame transferred to host buffer
GenICam features for Events:
EventSelector = {AcquisitionTrigger = 2, ExposureStart = 3, ExposureEnd = 4} EventNotification = {Off = 0, GigEVisionEvent = 1}
64 • Operational Reference Genie Monochrome Series-GigE Vision Camera
Description

This section describes how to optimize the network configuration for maximum Genie bandwidth. Optimization of these parameters is highly dependent on the number of cameras connected to a NIC, the data rate of each camera and the trigger modes used.
The Automatic Network Configuration mode sets parameters to a default state. The Optimize mode sets the packet size to the maximum value as reported by the NIC driver. If this does not provide satisfactory performance, it is possible to optimize transfers by manually setting the network configuration parameters. The following screen shot of the GigE Vision Parameters shows the CamExpert control set to Manual. Descriptions for each parameter follow.

Genie Monochrome Series-GigE Vision Camera Operational Reference • 65

Network Configuration Mode Specifies the Network Configuration Mode as either Automatic, Manual, or Optimize. In general use Optimize mode. Some computers, especially laptops, may require manual optimization of network parameters.
The following parameters can be modified when Manual mode is selected.
Inter-Packet Delay (in sec) Specifies the inter-packet delay, in sec. The range of permitted values is 0.000000 to 0.065535. The inter-packet delay is the minimum time interval between two successive packets. This can be increased if the NIC is unable to keep up with packet arrivals (thus dropping packets–seen as video noise).
Packet Size (in bytes) Specifies the maximum packet size, in bytes. The range of possible values is 576 to 1500, in increments of 4 bytes when the NIC does not support jumbo packet. The maximum is currently 9000 bytes when jumbo packets are supported (see "Increasing Adapter Buffers and Jumbo Frames" on page 24 to enable jumbo packets on the NIC). In most situations, use the largest possible packet size supported by your network elements. In order to support jumbo packets, all intermediate network elements must support them, otherwise they will simply be silently discarded and no image data will reach the PC.
Heartbeat Timeout (in Sec) Specifies the heartbeat timeout, in seconds. The range of permitted values is 0.5 to 65, in increments of 0.001 seconds. This is used by the camera to ensure the PC application is still linked. If the heartbeat timeout expires, the camera will shutdown the connection to the current application.
Maximum Packet Resend Sets the percentage of packets that can be resent for each frame. This is used to ensure the streaming data (including resends) does not exceed the Ethernet link capacity. As an example, a system capturing at 80 MB/s can allow 25% of packet resends without exceeding 100 MB/s (about the maximum capacity of a gigabit Ethernet link).
Genie Sapera parameters for Network Configuration:
NetworkConfigurationMode = {Automatic = 0, Manual = 1} InterPacketDelay = Minimum delay in µs between image packets PacketSize = Image packet size in bytes HeartbeatTimeout = Heartbeat period (watchdog) in ms before camera disconnect MaximumPacketResend = Sets percentage of packets that can be resent per frame
In CamExpert, these parameters are available under the “GigE Vision” tab. See "Accessing Features with Sapera++ LT" on page 68.
GenICam features for Network Configuration:
PayloadSize = Size of the payload in bytes. This is the total number of bytes sent in the payload. No packet headers.
Other networks parameters may be available through the 3rd party package used.
66 • Operational Reference Genie Monochrome Series-GigE Vision Camera
Parameter Description

On power up the Genie camera initializes to a factory default state which sets the camera with neutral parameters and in free run mode. The default state ensures that the camera is ready for acquisition. Genie also provides storage for one user-defined state. This user state allows quick camera configuration for a known repeatable imaging system. The following table describes the camera parameters stored in the user state. See "Power-up Configuration" on page 32 for information on saving the user state with CamExpert.
ROI Region of interest used to crop the image
Pixel Format Defines the pixel format (MONO8)
Frame Rate Defines the frame rate for free run mode.
Exposure mode Defines the exposure mode (Programmable or Pulse Controlled)
Exposure duration Defines the exposure duration for Programmable mode
Exposure synchronization Synchronous or Reset synchronization mode
Gain Defines the sensor analog Gain factor.
Black Level Defines the sensor analog Black level factor.
Binning Horizontal and vertical binning factor
Image source Defines the image source as the sensor or one of the stored image patterns.
Trigger enable Free-running or triggered
Trigger source Selects the trigger input (input pin or software)
Trigger delay Defines the delay from input trigger to exposure start.
GPI settings Defines the operational mode of the general input pins.
GPO settings Defines the operational mode of the general output pins
LUT Lookup Table function On or Off plus the LUT data.
Flat Field Correction FFC function On or Off plus the offset/gain data.
Genie Monochrome Series-GigE Vision Camera Operational Reference • 67
Parameter Description

Genie Sapera parameters for Power-up Configuration:
Power-upConfig = {Factory Default = 0, Camera Configuration 1 = 1} SaveCameraConfigurationSelector = {Camera Configuration 1 = 1} SaveCameraConfiguration = Write to save selected camera configuration LoadCameraConfigurationSelector = {Factory Default = 0, Camera Configuration 1 = 1} LoadCameraConfiguration = Write to load selected camera configuration
In CamExpert, these parameters are available in the “Camera Information” tab, under the “Power- up Configuration” dialog box. See "Accessing Features with Sapera++ LT" on page 68.
GenICam features for Power-up Configuration:
UserSetSelector = {Factory = 0, UserSet1 = 1} UserSetLoad = Loads the User Set specified by UserSetSelector to the camera and makes it active UserSetSave = Saves the User Set specified by UserSetSelector to the camera UserSetDefaultSelector = Selects the feature User Set to load at camera reset
The Genie features and its currently set values can be read by a Sapera application. The Sapera tool CamExpert is an example of an application that reads and writes Genie parameters to control its operation.
The following tables group the Genie features by their feature type—STRING, ENUM, INT32, and BOOL. Features may be read only (RO), read/write (RW), or write only (WO).
When working with Genie features, the SapAcqDevice class provides functions for accessing features from devices such as a GigE-Vision camera. The class also contains functions for sending commands and registering events to devices.
Refer to the Sapera++ LT Programmer's manual (OC-SAPM-SPPP0).
68 • Operational Reference Genie Monochrome Series-GigE Vision Camera


Number of Features RO STRING (number dependent on firmware version)
DeviceUserID RW STRING Inspection-1 (user set example)

DeviceScanType RO ENUM Area scan = 0 Linescan = 1
RO ENUM Monochrome Sensor = 0 CFA Bayer Sensor GR = 1 CFA Bayer Sensor RG = 2 CFA Bayer Sensor GB = 3 CFA Bayer Sensor BG = 4 RGB Sensor = 5
ExposureMode RW ENUM Programmable = 1 Pulse Controlled = 2
ExposureAlignment RW ENUM Synchronous = 0 Reset = 1
BinningVertical RW ENUM Disabled = 1 2 lines binned = 2
BinningHorizontal RW ENUM Disabled = 1 2 pixels binned = 2
RO ENUM Mono 8 - Unsigned = 16844800 Mono 9 - Unsigned = 16779520 Mono 10 - Unsigned = 16779776 RGB = 1124075520
Flip RW ENUM Off = 0 Horizontal = 1
TestImageSelector RW ENUM Off = 0 Grey Horizontal Ramp = 1 Grey Vertical Ramp = 2 Grey Diagonal Ramp Moving = 3 Purity = 4
Genie Monochrome Series-GigE Vision Camera Operational Reference • 69

LUTFormat (dependent on camera model)
RO ENUM Mono 8 - Unsigned = 16844800 Mono 8 - Signed = 285280256 Mono 9 - Unsigned = 16779520 Mono 9 - Signed = 285214976 Mono 10 - Unsigned = 16779776 Mono 10 - Signed = 285215232 RGB = 1124075520
TriggerSource RW ENUM Input 1 = 0 Input 2 = 1 Software = 2
OutputSelectorOutput_1 RW ENUM Open = 0 Close = 1 Strobe On: Start of Exposure = 2 Pulse On: Valid Trigger = 4 Pulse On: Invalid Trigger = 5 Pulse On: Start of Readout = 6 Pulse On: End of Readout = 7 Pulse On: End of Acquisition = 8 Pulse On: Input 1 = 9 Pulse On: Input 2 = 10
OutputSelectorOutput_2 RW ENUM Open = 0 Close = 1 Pulse On: End of Exposure = 3 Pulse On: Valid Trigger = 4 Pulse On: Invalid Trigger = 5 Pulse On: Start of Readout = 6 Pulse On: End of Readout = 7 Pulse On: End of Acquisition = 8 Pulse On: Input 1 = 9 Pulse On: Input 2 = 10
PolarityInput_1 RW ENUM Active High = 0 Active Low = 1
PolarityInput_2 RW ENUM Active High = 0 Active Low = 1
PolarityOutput_1 RW ENUM Active Close = 0 Active Open = 1
PolarityOutput_2 RW ENUM Active Close = 0 Active Open = 1
PixelFormat RW ENUM Monochrome, 8-bit = 17301505 (0x1080001) 10-bit = 17825795 (0x1100003)
Power-upConfig RW ENUM Factory Default = 0 Camera Configuration 1 = 1
SaveCameraConfigurationSelector RW ENUM Camera Configuration 1 = 1
LoadCameraConfigurationSelector RW ENUM Factory Default = 0 Camera Configuration 1 = 1
NetworkConfigurationMode RW ENUM Automatic = 0 Manual = 1
70 • Operational Reference Genie Monochrome Series-GigE Vision Camera

The feature list for type INT32 has an additional column 'Exponent' which defines the feature's native unit. This exponent value is used as a unit multiplier so that the feature value is expressed as an integer, not a decimal number.

Genie Monochrome Series-GigE Vision Camera Operational Reference • 71

Feature Name Access Type Value
LUTEnable RW BOOL True/False
TriggerEnable RW BOOL True/False
TriggerSoftware RW BOOL True/False
FlatFieldEnable RW BOOL True/False
SaveCameraConfiguration WO BOOL True/False
LoadCameraConfiguration WO BOOL True/False
The following diagrams describe operational feature availability which are dependent on user selected modes. These diagrams show what features are set to a value, and they show which feature parameters remain as user variables.
Each diagram uses the following symbol set to indicate the dependent action type.
gray box User Action
Function Enabled The event “Feature Info Changed” is sent. Other feature properties might have changed too.
Function Disabled The event “Feature Info Changed” is sent. Other feature properties might have changed too.
Forced Value The event “Feature Value Changed” is sent if the forced value is different from the previous value.
Set Max Value The event “Feature Info Changed” is sent if the new value is different than the previous value.
Set Max Value The event “Feature Value Changed” is sent if the new range causes the value to be not within the valid range. The feature is usually set to the new maximum. When the maximum range increases, the “Feature Value Changed” event is never set.
72 • Operational Reference Genie Monochrome Series-GigE Vision Camera

TRUE
Trigger Delay to Integration
FALSE
Trigger Delay to Integration
Genie Monochrome Series-GigE Vision Camera Operational Reference • 73

Output X Pulse Delay
Output X Pulse Duration
Output X Pulse Delay
Output X Pulse Duration
Horizontal Binning
74 • Operational Reference Genie Monochrome Series-GigE Vision Camera

Network Configuration Mode
Genie Monochrome Series-GigE Vision Camera Operational Reference • 75

76 • Operational Reference Genie Monochrome Series-GigE Vision Camera

IP Configuration Mode Details
The following descriptions provide more information on the IP configuration modes supported by Genie. In general automatic IP configuration assignment is sufficient for most Genie installations.
Ensure only one NIC is using LLA on your PC, otherwise IP conflicts will result.
connectivity".
This is normal (see Microsoft KB article #892896) and indicates that the network does not have connectivity beyond routers.
Genie Monochrome Series-GigE Vision Camera Network Tools • 77

78 • Network Tools Genie Monochrome Series-GigE Vision Camera

The Network Configuration tool provides information on all network adapters installed in the system and any connected GigE Vision devices. For the Genie, the tool allows a simple method to assign a User-Defined name and also to set a Persistent IP address instead of the default DHCP/LLA assigned IP address. Using this tool, Genie network configurations can be easily made without having to use any Windows Control Panel application.

Genie Monochrome Series-GigE Vision Camera Network Tools • 79
Genie Network Information


Select the system icon (the computer symbol) in the left pane to display current system information which may be required when documenting Genie installations. There are no user changeable fields in the System Information tab.
In the right hand pane click on the System Configuration tab. By default the Sapera GigE Server is added to the Windows Firewall exception list. This function is performed automatically when the Genie software package is installed. This ensures the Windows Firewall remains active (if it was enabled) without having to individually put each Genie application program in the exception list.

If the computer is using a different firewall software package, refer to that firewall's software manual to allow the Sapera GigE Server to have access through it.
Alternatively, it is possible to exclude a specified NIC from using the firewall. The NIC dedicated to the Genie camera does not need Windows firewall. See "Disabling Windows Firewall" on page 107 for details on excluding a NIC from firewall settings.
80 • Network Tools Genie Monochrome Series-GigE Vision Camera
Genie IP Configuration · System Firewall Configuration

Select a network card icon in the left pane to see the NIC configuration parameters. The Network Configuration tool ensures that no two NIC devices installed in the computer are on the same subnet, since that would create a conflict. A warning message is displayed in such a case, indicating that a settings change is required for one of the NIC.

For each NIC, it is possible to configure the IP configuration mode (either DHCP/LLA or Persistent IP) if required via the NIC Configuration tab.

Genie Monochrome Series-GigE Vision Camera Network Tools • 81
NIC Information

After installation, all system NIC devices have the Sapera Network Imaging driver enabled. Only the NIC connected to a Genie camera requires the Network Imaging driver enabled to capture images from Genie. The Network Imaging driver streams image data efficiently to image buffers.
Select other NIC devices in the system and disable the Network Imaging Driver if they are not used with a Genie camera.
When a Genie camera has been configured with a persistent IP address, that camera can not be controlled if its IP address has been lost or forgotten. The DALSA Network Configuration tool provides a function to recover cameras and reset them back to the DHCP/LLA mode. The camera can also be set to a new persistent IP address immediately if required.

82 • Network Tools Genie Monochrome Series-GigE Vision Camera
Camera Recovery Dialog

This section provides additional details on the GigE Server not covered in the Genie installation section of this manual. Generally the Genie automatic installation requires no user intervention.
Genie Monochrome Series-GigE Vision Camera Network Tools • 83

User Name User assigned identification
Manufacturer Manufacturer for this device
Model GigE Vision device model
Serial Number Device serial number
Firm Ver Device firmware revision number
MAC adddress Device MAC address
Camera IP Device current IP address
NIC IP NIC IP associated with the GigE server
Filter driver Network driver status
MaxPktSize Largest packet size that should be used for image streaming. This is found using the Test Packet mechanism of GigE Vision.
ABI Sapera Application Binary Interface to communicate with the device
Status General device status
Before contacting DALSA technical support, the user should review the Troubleshooting section of this manual (see "Troubleshooting" on page 101). Most installation, configuration, and imaging issues are documented along with their solutions.
To aid technical support, the tool can save a network configuration report. From the File menu select “Save current status”. You will be prompted for a filename for the report text file. This file should always be sent with any request for technical support.
84 • Network Tools Genie Monochrome Series-GigE Vision Camera

Using CamExpert with Genie Monochrome Cameras
CamExpert is the camera interfacing tool supported by the Sapera library. When used with a Genie camera, CamExpert allows a user to test all Genie operating modes. Additionally CamExpert saves the Genie user settings configuration to the camera or saves multiple configurations as individual camera parameter files on the host system (*.ccf).
An important component of CamExpert is its live acquisition display window which allows immediate verification of timing or control parameters without the need to run a separate acquisition program.
For context sensitive help, click on the
button then click on a camera configuration parameter. A short
description of the configuration parameter will be shown in a popup. Click on the
button to open the help file for more descriptive information on CamExpert.
The central section of CamExpert provides access to the Genie parameters. Five tabs group Genie parameters depending on their type as described in the summary below. Each Genie configuration parameter is described in detail following the summary.
Camera Information Displays Genie firmware details such as camera model, version, serial number and MAC address. Users can set the User ID and set the power-up configuration mode.
Sensor Parameters Displays both static and variable sensor parameters that are Genie model specific. Variable parameters control Genie exposure, binning, gain and exposure controls. The internal test image is selected here.
I/O Controls Provides controls for trigger source and I/O pin configuration.
Image Buffer and ROI Provides controls for buffer pixel depth, image size and cropping.
GigE Vision Provides advance controls to optimize the network connection.
Genie Monochrome Series-GigE Vision Camera Sapera CamExpert Guide • 85

The CamExpert application uses 5 windows to simplify choosing and configuring camera files or acquisition parameters for the installed device.
86 • Sapera CamExpert Guide Genie Monochrome Series-GigE Vision Camera

Acquisition control button: Click once to start live grab, click again to stop.
Single frame grab: Click to acquire one frame from device.
Software trigger button: With the I/O control parameters set to Trigger Enabled / Software Trigger type, click to send a single software trigger command.
CamExpert display controls: (these do not modify the frame buffer data) Stretch image to fit, set image display to original size, or zoom the image to any size and ratio.
Histogram / Profile tool: Select to view a histogram or line/column profile during live acquisition.
Most of these panes can be hidden via the menu bar view command. Typically after selecting an acquisition device and loading a camera file, the Device and Camera windows can be closed.
The Lookup Table dialog allows you to configure the LUT if it is available on the device. Genie monochrome cameras support an 8-bit or 10-bit LUT. To open this dialog, use the Pre-Processing > Lookup Table > Setting menu command. Note that you must first enable the Lookup Table, otherwise the Setting command will be grayed- out.

To select the type of LUT to use, click the LUT Mode Value field; a drop-down list box displays the available modes. The Lookup Table dialog displays a graph of the input and output values for the selected LUT. These are CamExpert common examples for LUT operations. A Sapera application can program the Genie LUT for any required LUT operation. See "Lookup Table (LUT)" on page 56 for Genie LUT support.
Genie Monochrome Series-GigE Vision Camera Sapera CamExpert Guide • 87


CamExpert available LUT examples are briefly described below. The LUT function graphic simplifies understanding the operation especially when user settings modify the LUT function.
88 • Sapera CamExpert Guide Genie Monochrome Series-GigE Vision Camera
10-bit Invert LUT

Mechanical Specifications
The figure below defines the Genie family mechanical specifications. Additional notes follow.

Genie Monochrome Series-GigE Vision Camera Technical Specifications • 89

The following figure shows the pinout identification when looking at the Genie camera 12-pin male Hirose connector. The table below the figure lists the Genie I/O signal specifications.

Pin Direction Genie Signal (see details below) Notes
3 Out Output 1 -
4 Out Output 1 +
5 In Input 1 - RS422- or TTL GND
6 In Input 1 + RS422+ or TTL
7 Out Output 2 + / Strobe +
8 Out Output 2 - / Strobe -
11 In Input 2 + RS422+ or TTL
12 In Input 2 - RS422- or TTL GND
shell / shield via cable shield Genie chassis connects to supply earth ground improves EMI shielding
90 • Technical Specifications Genie Monochrome Series-GigE Vision Camera

3.3V Genie example TTL external
device 4.7K
.01µf
External Input Detail with an Example Signal Driver
The opto-coupler is typically a Fairchild HMHA281 with the following characteristics.
Input Electrical Parameter Description Value
Voltage threshold to turn OFF 0.8 V
Voltage threshold to turn ON 2 V
Minimum input current to turn ON 2 mA
Maximum input current 50 mA
Minimum input pulse width to turn ON 30 us
Maximum input voltage 13 V
Genie Monochrome Series-GigE Vision Camera Technical Specifications • 91

OUT+
OUT-
NEC PS2805-1
The opto-coupler is typically a NEC PS2805-1 with the following characteristics.
Output Electrical Parameter Description Value
Maximum voltage difference 13 V
Maximum current through opto-coupler 12mA
Minimum output pulse width 100 us
Maximum switch closure transition time 12 µs
Maximum switch open transition time 40 µs
The RJ45 LAN connector has two LEDs for network status conditions.
The LED color codes are as follows.
Network Connection Network Activity
Green 100Mbps Off no network activity
Orange 1000Mbps Yellow typically blinking – active
Network Connection Network Activity
The Genie LAN connector is a standard Ethernet socket. Use CAT5e or CAT6 certified Ethernet cables. CAT5e cable is rated for 100 MHz spectral bandwidth but CAT6 cable is rated for a 200 MHz spectral bandwidth with less signal attenuation, therefore strongly recommended for long connection lengths.
The interconnection Ethernet cable can be either Straight Through or Crossover cable type. The Gigabit Ethernet standard for devices defines that they will auto-negotiate send and receive channels, eliminating the need for users to use a specific Ethernet cable type.
92 • Technical Specifications Genie Monochrome Series-GigE Vision Camera

The Genie has one multicolor LED to provide a simple visible indication of the operational status of the camera. When more than one condition is active, the LED color indicates the condition with the highest priority. The following table summarizes the LED states and corresponding camera status.
LED is off No power to the camera
Steady Red Camera not initialized
Slow Flashing Red Camera initialization problem
Fast Flashing Red Camera is too hot
Slow Flashing Blue Waiting for an IP address
Fast Flashing Blue Ethernet cable disconnected (no link)
Steady Blue IP address assigned; no application connected to the camera
Steady Green Application connected
Slow Flashing Green Triggered acquisition in progress
Fast Flashing Green Free running acquisition in progress
This section provides an overview to illumination, light sources, filters, lens modeling, and lens magnification. Each of these components contribute to the successful design of an imaging solution.
The amount and wavelengths of light required to capture useful images depend on the particular application. Factors include the nature, speed, and spectral characteristics of objects being imaged, exposure times, light source characteristics, environmental and acquisition system specifics, and more. The DALSA Web site, http://vfm.dalsa.com/ provides an introduction to this potentially complicated issue. Click on the Application Support link and then select the CCD Technology Primer. Review “Radiometry and Photo Responsivity” along with other sections of interest.
It is often more important to consider exposure than illumination. The total amount of energy (which is related to the total number of photons reaching the sensor) is more important than the rate at which it arrives. For example, 5μJ/cm2 can be achieved by exposing 5mW/cm2 for 1ms just the same as exposing an intensity of 5W/cm2 for 1μs.
Keep these guidelines in mind when selecting and setting up light source:
Genie Monochrome Series-GigE Vision Camera Technical Specifications • 93
LED State Definition

CCD cameras are extremely responsive to infrared (IR) wavelengths of light. To prevent infrared from distorting the images you scan, use a “hot mirror” or IR cutoff filter that transmits visible wavelengths but does not transmit wavelengths over 750nm. Examples are the Schneider Optics™ B+W 489, which includes a mounting ring, the CORION™ LS-750, which does not include a mounting ring, and the CORION™ HR-750 series hot mirror.
Any lens surrounded by air can be modeled for camera purposes using three primary points: the first and second principal points and the second focal point. The primary points for a lens should be available from the lens data sheet or from the lens manufacturer. Primed quantities denote characteristics of the image side of the lens. That is, h is the object height and h′ is the image height.
The focal point is the point at which the image of an infinitely distant object is brought to focus. The effective focal length (f′) is the distance from the second principal point to the second focal point. The back focal length (BFL) is the distance from the image side of the lens surface to the second focal point. The object distance (OD) is the distance from the first principal point to the object.

The magnification of a lens is the ratio of the image size to the object size:
h h m ' =
Where m is the magnification, h’ is the image height (pixel size) and h is the object height (desired object resolution size).
By similar triangles, the magnification is alternatively given by:
f m ' =
These equations can be combined to give their most useful form:
f h h ' ' =
This is the governing equation for many object and image plane parameters.
94 • Technical Specifications Genie Monochrome Series-GigE Vision Camera

Example: An acquisition system has a 512 x 512 element, 10μm pixel pitch area scan camera, a lens with an effective focal length of 45mm, and requires that 100μm in the object space correspond to each pixel in the image sensor. Using the preceding equation, the object distance must be 450mm (0.450m).
mm m m 45 100 10 = μ μ
) 450 .0 ( 450 m mm OD =
Sensor Handling Instructions
This section reviews proper procedures for handling, cleaning, or storing the Genie camera. Specifically the Genie CCD sensor needs to be kept clean and away from static discharge to maintain design performance.
Cameras contain charge-coupled device (CCD) image sensors, which are metal oxide semiconductor (MOS) devices and are susceptible to damage from electrostatic discharge (ESD).
Electrostatic charge introduced to the sensor window surface can induce charge buildup on the underside of the window that cannot be readily dissipated by the dry nitrogen gas in the sensor package cavity. When charge buildup occurs, surface-gated photodiodes (SGPDs) may exhibit higher image lag or a highly non-uniform response, with some pixels displaying a much higher response when the sensor is exposed to uniform illumination. The charge normally dissipates within 24 hours and the sensor returns to normal operation.
The CCD window is part of the optical path and should be handled like other optical components, with extreme care.
Dust can obscure pixels, producing dark patches on the sensor response. Dust is most visible when the illumination is collimated. The dark patches shift position as the angle of illumination changes. Dust is normally not visible when the sensor is positioned at the exit port of an integrating sphere, where the illumination is diffuse.
Dust can normally be removed by blowing the window surface using a compressed air blower, unless the dust particles are being held by an electrostatic charge, in which case either an ionized air blower or wet cleaning is necessary.
Oil is usually introduced during handling. Touching the surface of the window barehanded will leave oily residues. Using rubber finger cots and rubber gloves can prevent oil contamination. However, the friction between the rubber and the window may produce electrostatic charge that may damage the sensor.
Scratches can be caused by improper handling, cleaning or storage of the camera. When handling or storing the Genie camera without a lens, always install the C-mount protective cap. Scratches diffract incident illumination. When exposed to uniform illumination, a sensor with a scratched window will normally have brighter pixels adjacent to darker pixels. The location of these pixels changes with the angle of illumination.
Genie Monochrome Series-GigE Vision Camera Technical Specifications • 95

Even with careful handling, the sensor window may need cleaning. The following steps describe various cleaning techniques to clean minor dust particles to accidental finger touches.
96 • Technical Specifications Genie Monochrome Series-GigE Vision Camera

Components Express Inc. has available an industrial RJ45 CAT6 cable that on one end has a molded shroud assembly with top/bottom thumbscrews, while the other end has a standard RJ45. This cable is recommended when Genie is installed in a high vibration environment.
Contact sales at DALSA for availability of Genie with female mounts for this secure Ethernet cable.

Components Express, Inc. (CEI) 10330 Argonne Woods Drive, Suite 100 Woodridge, IL 60517-4995 Phone: 630-257-0605 / 800.578.6695 (outside Illinois) Fax: 630-257-0603 http://www.componentsexpress.com/
All cables made in U.S.A. – all cables RoHS compliant. CAT6 certified (tested for near end / far end crosstalk and return loss).
IGE-3M (3meters) IGE-10M (10meters) IGE-25M (25meters) IGE-50M (50meters) IGE-100M (100meters)
Genie Monochrome Series-GigE Vision Camera Technical Specifications • 97

The following information is a guide to computer and networking equipment required to support the Genie camera at maximum performance. The Genie camera series complies with the current IPv4 Internet Protocol, therefore current Gigabit Ethernet (GigE) equipment should provide trouble free performance.
When there is more than one device on the same network or a camera-to-PC separation greater than 100 meters, an Ethernet switch is required. Since the Genie GigE camera complies with the Internet Protocol, it should work with all standard Ethernet switches. However, switches offer a range of functions and performance grades, so care must be taken to choose the right switch for a particular application. The following switches are expected to work with the camera but manufacturers may change specifications and features at anytime:
98 • Technical Specifications Genie Monochrome Series-GigE Vision Camera

In cases of camera-to-PC separations of more than 100 meters but an Ethernet switch is not desired, a fiber-optic media converter can be used. The FlexPoint GX from Omnitron Systems (http://www.omnitron-systems.com/) converts GigE to fiber transmission and vice versa. It supports multimode (MM) fiber over distances of up to 220 m (720 ft.) and single-mode (SM) fiber up to 65 km (40 mi.) with SC, MT-RJ, or LC connector types.
Genie Monochrome Series-GigE Vision Camera Technical Specifications • 99


100 • Technical Specifications Genie Monochrome Series-GigE Vision Camera

Overview
In rare cases an installation may fail or there are problems in controlling and using the Genie camera. This section highlights issues or conditions which may cause installation problems and additionally provides information on computers and network adapters which have caused problems with Genie. Emphasis is on the user to perform diagnostics with the tools provided and methods are described to correct the problem.
The GigE Server status provides visual information on possible Genie problems. The three states are shown in the following table. Descriptions of possible conditions causing an installation or operational problem follow. Note that even a Genie installation with no networking issue may still require optimization to perform to specification.
Device Not Available Device IP Error Device Available
GigE Server Tray Icon:
A red X will remain over the GigE server tray icon when the Genie device is not found. This indicates a network issue where there is no communication with Genie.
The GigE server tray icon shows a warning when a device is connected but there is some type of IP error.
The GigE server tray icon when the Genie device is found. The Genie has obtained an IP address and there are no network issues. Optimization may still be required to maximize performance.
Genie problems are either installation types where the Genie is not found on the network or setup errors where the Genie device is found but not controllable. Additionally a Genie may be properly installed but network optimization is required for maximum performance. The following links jump to various topics in this troubleshooting section.
Genie Monochrome Series-GigE Vision Camera Troubleshooting • 101

A red X over the GigE server tray icon indicates that the Genie device is not found. This indicates either a major camera fault or condition such as disconnected power, or a network issue where there is no communication.
The GigE server tray icon shows a warning with IP errors. Review the following topics on network IP problems to identify and correct the condition.
A properly installed Genie with no network issues may still not perform optimally. Operational issues concerning cabling, Ethernet switches, multiple cameras, and camera exposure are discussed in the following sections:
102 • Troubleshooting Genie Monochrome Series-GigE Vision Camera

This section covers issues indicated by the GigE server tray icon shows a warning symbol.
The screenshot below shows an IP conflict error due to two (or more) NICs that are all set to LLA mode. In this case both NICs are assigned the same IP address preventing communication with any connected Genie.

LLA Mode (only 1 NIC)
NIC 2
Persistence Mode - OK
Genie Monochrome Series-GigE Vision Camera Troubleshooting • 103

As a second example, the screenshot below shows an IP conflict error similar to the example above but the second NIC has no camera connected (or only an Ethernet switch).

LLA Mode (only 1 NIC)
NIC 2
Persistence Mode - OK
104 • Troubleshooting Genie Monochrome Series-GigE Vision Camera

The screenshot below shows that the Genie device is not accessible. This IP error is an example of the Genie being assigned a persistent IP address with an incorrect subnet mask.

The screenshot below shows that the Genie device was found but there is an issue with the filter driver (CorSnid). Such problems occur because the filter driver has become disabled or never installed correctly.

Genie Monochrome Series-GigE Vision Camera Troubleshooting • 105


This section considers issues with cabling, Ethernet switches, multiple cameras, and camera exposure.
As a general rule any Genie installation must include the firmware update procedure (see "Updating Genie Firmware" on page 27). Genie camera firmware that does not match a newer version of installed Genie Framework software is likely to have unpredictable behavior. Problems might be:
106 • Troubleshooting Genie Monochrome Series-GigE Vision Camera

Don't panic! There is far greater chance that the host computer OS is damaged during a power failure than any permanent problems with the Genie. When electrical power returns and the host computer system has started, the Genie firmware reprogramming sequence is as follows.
A streaming error is typical with a firewall not allowing the filter driver through. As an example, CamExpert will run (but start slowly due to initialization timeouts), the Genie is visible in the device pane, but no parameters are shown to control the camera.

Connecting the Genie camera to a system running a firewall would require careful planning of the camera IP and the ports used by the streaming video and messaging. In general, the Genie camera is installed in a private network or within a corporate network with an external firewall. In both these cases, the host system that the Genie connects to does not need to run a firewall, therefore eliminating installation issues.
The Network Configuration tool automatically adds the Sapera GigE Server in the list of Exceptions of the Windows firewall. Therefore, in most situations, you don’t have to take any special precaution to have the Genie run through the firewall.
Genie Monochrome Series-GigE Vision Camera Troubleshooting • 107


Turning Windows Firewall Off
With a computer that is not behind a corporate firewall an alternative is to disable Windows firewall only for the network adapter dedicated for the Genie camera. Such a computer would have two or more network adapters where one NIC only connects to the Genie—never the Internet.
The following figures show an example of the Windows firewall On but disabled for the network adapter used by Genie.


Windows Firewall Off for Genie Only
108 • Troubleshooting Genie Monochrome Series-GigE Vision Camera

The Genie test pattern mode allows quick verification of an installation without the need for correct lighting or lens. Troubleshooting physical connection issues or communication problems is made easier knowing that the camera can output a known video signal at selectable frame rates. See "Internal Image Test Patterns" on page 62 for information on using CamExpert to select internal patterns from Genie.
With only two cables connected to Genie, possible cabling issues are limited.
Streaming video problems range from total loss of image data to occasional loss of random video data packets. The following section describes conditions identified by DALSA engineering while working with Genie in various computers and setups.
Genie Monochrome Series-GigE Vision Camera Troubleshooting • 109

While using CamExpert to test a Genie installation, there are no obvious installation problems. But when Grab is clicked in CamExpert, a grab failure occurs. The grab remains black and an Abort message is displayed.
The problem is seen as random noise and missing sections of video data from the acquisition. All configuration parameters seem correct and the Ethernet cable is secure. The following image shows an example of this type of bad acquisition while testing a Genie installation with CamExpert (with the Genie set to generate its internal test pattern).

Following are various examples of this data transmission problem. The solutions vary but commonly involve reducing the maximum packet size claimed by the NIC used.
110 • Troubleshooting Genie Monochrome Series-GigE Vision Camera


Laptop computers with built in GigE network adapters may still not be able to stream full frame rates from Genie. Laptops with gigabit Ethernet PCMCIA boards may not be able to stream video at all unless network parameters are modified. Thorough testing is required with any laptop computer.
Streaming video problems may change depending on the computer chipset and NIC combinations. Laptops running on battery power may exhibit more bandwidth issues due to the inherent power saving characteristics of laptops.
This section describes a few configuration items to modify for best performance. Verify the Genie at the frame rates required or to determine the maximum frame rate possible with the laptop used.
Genie Monochrome Series-GigE Vision Camera Troubleshooting • 111

If a laptop has had a Genie installed on it and a new NIC is later installed on the laptop, a Genie connected to the new NIC will not be found. A quick solution is to deselect/reselect the CorSnid driver on that NIC as follows.

112 • Troubleshooting Genie Monochrome Series-GigE Vision Camera
CorSnid Driver Selection

Genie cameras installed in environments with physical motion, vibrations, or high EMI may be disconnected by the NIC. The following items need to be reviewed to solve the problem.
An Ethernet switch usually works transparently and presents no problems. Review the following list when troubleshooting switch issues.
Genie Monochrome Series-GigE Vision Camera Troubleshooting • 113

No camera exposure when expected.
Camera is functional but frame rate is lower than expected.
Camera is functional, frame rate is as expected, but image is black.
114 • Troubleshooting Genie Monochrome Series-GigE Vision Camera

DALSA provides the Network Configuration tool to verify and configure network devices and the Genie network parameters. See section "Network Configuration Tool" on page 79 if there were any problems with the automatic Genie software installation.
VPN (virtual private network) software using a driver component called "Deterministic Network Enhancement" has been identified as interfering with the Genie operation when using Framework versions previous to 1.20. At the time to solution was to disable this VPN driver by deselecting the component from the NIC properties (see following figure).
With Genie Framework version 1.20 or later, there is no need to disable this VPN component.

Genie Monochrome Series-GigE Vision Camera Troubleshooting • 115

116 • Troubleshooting Genie Monochrome Series-GigE Vision Camera

Genie Sales Information
DALSA — Montreal office 7075 Place Robert-Joncas Suite #142 St. Laurent, Quebec, Canada H4M 2Z2
DALSA 700 Technology Park Drive Billerica, Ma. 01821
Genie Monochrome Series-GigE Vision Camera DALSA Contact Information • 117

Technical support form via our web page: Support requests for imaging product installations, Support requests for imaging applications
http://www.imaging.com/support
Product literature and driver updates http://www.imaging.com/download
118 • DALSA Contact Information Genie Monochrome Series-GigE Vision Camera

ARP Address Resolution Protocol provides a way to retrieve the MAC address associated to an IP address.
Bandwidth Describes the measure of data transfer capacity.
CAT5e Ethernet cable Category 5e was designed for transmission speeds of up to 1 gigabit per second (Gigabit Ethernet).
CAT6 Ethernet cable Same as Category 5e, except that it is made to a higher standard. Supports transmission speeds greater than Gigabit Ethernet with less signal attenuation over a given length of cable.
CCD – Charge-Coupled Device A type of image sensor converting light into electrical charges.
Contiguous Memory A block of physical memory occupying consecutive addresses.
DHCP (Dynamic Host Configuration Protocol) Protocol which provides a mechanism for allocating IP addresses dynamically by a DHCP server on a network. Typically dedicated DHCP servers are a component of corporate networks. Used for managed networks.
Driver Also called a device driver, a program routine that links a peripheral device to the operating system. a device driver is required for its frame grabber capabilities.
DSNU Dark Signal Non-Uniformity (equivalent to FPN).
Ethernet Switch A network device performing bridging at full wire-speed based on MAC addresses. Packet collisions are eliminated when using a full duplex switch. An Ethernet Switch operates at Layer 2 of the seven-layer OSI model.
FPN Fixed Pattern Noise (equivalent to DSNU). FPN is the peak to peak difference between the minimum and maximum measured values for all active valid pixels sensor in darkness. Fixed Pattern Noise does not include a Random Noise component.
Frame One complete image data set or its equivalent storage space.
Frame buffer An area of memory used to hold a frame of image data. A frame buffer may exist on the acquisition hardware or be allocated by the acquisition hardware device driver in host system memory.
GigE Vision specification Specification of the Automated Imaging Association (AIA, www.machinevisiononline.org). Defines the communication interface protocol used by any GigE Vision device.
Genie Monochrome Series-GigE Vision Camera Glossary of Terms • 119

GenICam specification Specification of the European Machine Vision Association (EMVA, www.emva.org). Defines the capabilities of any GigE Vision device.
Grab Acquiring an image frame.
Grayscale In image processing, the range of available brightness levels, displayed in shades of gray. In an 8-bit system, the gray scale contains values from 0 to 255. A 10-bit system has a range of 0-1023.
GVCP – GigE Vision Control Protocol One of the core protocols of the GigE Vision specification used to control camera. GVCP uses UDP port 3956 on the camera.
GVSP – GigE Vision Stream Protocol One of the core protocols of the GigE Vision specification used to stream images.
Host Refers to the computer system that supports the installed frame grabber.
IP – Internet Protocol The Internet Protocol is the method by which data is sent from one computer to another on a network or across the Internet. Each device must have an IP address to identify that device on the network or on the Internet.
LLA Link-Local Address is a protocol providing a scheme for devices to automatically assign themselves an IP address and check for IP conflict. Used in unmanaged networks.
NIC Network Interface Card/Controller. For the Genie products the NIC must be a Gigabit Ethernet interface to provide sufficient bandwidth.
Pixel A contraction of "picture element". The number of pixels describes the number of digital samples taken of the analog video signal. The number of pixels per video line by the number of active video lines describes the acquisition image resolution. The binary size of each pixel (e.g., 8-bits, 16-bits, 24-bits) defines the number of gray levels or colors possible for each pixel.
PRNU Photo-Response Non-Uniformity. For a given even illumination the difference between the minimum and maximum measured pixel values is the PRNU.
Progressive Scan Camera The progressive scan format outputs data from the camera (the signal) in sequential order as it is scanned. The scan format produces a full frame of video in a continuous stream, rather than half the image per output sequence in standard interlaced cameras.
Random Noise Random noise is defined as the difference in peak to peak value for any single pixel repetitively sampled, with the sensor in darkness. For digital cameras the measurement is based on at least 512 samples from any pixel.
Router A Router device forwards packets across networks. It operates at Layer 3 of the seven-layer OSI model. Note that broadcast packets (such as GigE Vision Device Discovery message) do not cross routers.
120 • Glossary of Terms Genie Monochrome Series-GigE Vision Camera

SAT Saturation Output Amplitude. SAT is the average maximum output level for a specified light input.
Scatter Gather Host system memory allocated for frame buffers is virtually contiguous but physically scattered throughout all available memory.
SNR Signal to Noise Ratio. SNR measures the ratio between random noise and an arbitrary reference signal on the transmission path or within a device.
Subnet The subnet is identified by performing the logical AND of the IP address with its subnet mask.
TCP Connection-oriented transport protocol providing robustness and reliability. Used by many Internet application, such as HTML.
Trigger A mechanism that initiates an action when an event occurs such as synchronizing an image acquisition to an external event. A trigger generally causes a program routine to be executed such as the resetting of camera exposure and/or the firing of a strobe light.
UDP User Datagram Protocol is a connectionless transport protocol providing no guaranty of delivery or reliability. GigE Vision Control Protocol and GigE Vision Stream Protocol are based on UDP.
VLAN A Virtual Local Area Network is a flexible arrangement where computers connected via a VLAN Ethernet switch are not necessarily on the same LAN broadcast domain. Refer to the VLAN Ethernet switch documentation for implementation and configuration details.
VPN A virtual private network is a private data network that makes use of the public telecommunication infrastructure, maintaining privacy through the use of a tunneling protocol and security procedures. The idea of the VPN is to give the company the same capabilities at much lower cost by using the shared public infrastructure rather than a private one. (source: www.netunlimited.com/glossary.html )
Genie Monochrome Series-GigE Vision Camera Glossary of Terms • 121

122 • Glossary of Terms Genie Monochrome Series-GigE Vision Camera



Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.