UNVENTED (VENT-FREE) GAS STOVE HEATER OWNER’S OPERATION AND INSTALLATION MANUAL

Propane/LP and Natural Gas Thermostat Control Gas Log Heaters
(Burner System For Cast Iron Stoves)
vapors and liquids in the vicinity of this or any other appliance. — WHAT TO DO IF YOU SMELL GAS
fied installer, service agency or the gas supplier.
Save this manual for future reference. For more information, visit www.desatech.com

This appliance may be installed in an aftermarket,* per- manently located, manufactured (mobile) home, where not prohibited by local codes. This appliance is only for use with the type of gas indi- cated on the rating plate. This appliance is not convert- ible for use with other gases.
State of Massachusetts: The installation must be made by a licensed plumber or gas fitter in the Commonwealth of Massachusetts.
Sellers of unvented propane or natural gas-fired supplemental room heaters shall provide to each purchaser a copy of 527 CMR 30 upon sale of the unit.
Vent-free gas products are prohibited for bedroom and bathroom installation in the Common- wealth of Massachusetts.
Safety Information 3 Product Identification 4 Local Codes 4 Product Features 5 Air for Combustion and Ventilation 5 Unpacking 7 Installation 8 Operating Heater 13 Inspecting Burners 14 Cleaning and Maintenance 14
Troubleshooting 16 Specifications 19 Service Hints 19 Technical Service 19 Replacement Parts 19 Accessories 19 Illustrated Parts Breakdown and Parts List 20 Parts Centrals 23 Warranty Information Back Cover

Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies.
Do not place clothing or other flammable material on or near the appliance. Never place any objects on the heater.
Stove becomes very hot when running heater. Keep children and adults away from hot surface to avoid burns or clothing igni- tion. Heater will remain hot for a time after shutdown. Allow sur- face to cool before touching.
Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with head- aches, dizziness or nausea. If you have these signs, the heater may not be working properly. Get fresh air at once! Have heater serviced. Some people are more affected by carbon monoxide than others. These include pregnant women, people with heart or lung disease or anemia, those under the influence of alcohol and those at high altitudes.
Carefully supervise young chil- dren when they are in the room with heater.
Natural and Propane/LP Gas: Natural and pro- pane/LP gases are odorless. An odor-making agent is added to the gas. The odor helps you detect a gas leak. However, the odor added to the gas can fade. Gas may be present even though no odor exists. Make certain you read and understand all warn- ings. Keep this manual for reference. It is your guide to safe and proper operation of this heater.
Keep the appliance area clear and free from combustible ma- terials, gasoline and other flam- mable vapors and liquids.

One Piece Log Set Inside Stove Cavity

Stove Door (Shown in the open position)
Figure 1 - Typical Stove Cabinet Model
with Comfort Glow Gas Log Heater
LOCAL CODES Install and use heater with care. Follow all local codes. In the absence of local codes, use the lat- est edition of The National Fuel Gas Code ANSI Z223.1/NFPA 54*. *Available from: American National Standards Institute, Inc.
1430 Broadway New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park Quincy, MA 02269

All spaces in homes fall into one of the three fol- lowing ventilation classifications: 1. Unusually Tight Construction 2. Unconfined Space 3. Confined Space The information on pages 5 through 7 will help you classify your space and provide adequate ventilation.
OPERATION This heater is clean burning. It requires no outside venting. There is no heat loss out a vent or up a chimney. Heat is generated by realistic, dancing yellow flames. This heater is designed for vent-free operation. State and local codes in some areas prohibit the use of vent-free heaters.
Unusually Tight Construction The air that leaks around doors and windows may provide enough fresh air for combustion and ven- tilation. However, in buildings of unusually tight construction, you must provide additional fresh air. Unusually tight construction is defined as construction where: a. walls and ceilings exposed to the out-
SAFETY PILOT This heater has a pilot with an Oxygen Deple- tion Sensing (ODS) safety shutoff system. The ODS/pilot is a required feature for vent-free room heaters. The ODS/pilot shuts off the heater if there is not enough fresh air.
PIEZO IGNITION SYSTEM This heater has a piezo ignitor. This system requires no matches, batteries or other sources to light heater.
side atmosphere have a continuous water vapor retarder with a rating of one perm (6 x 10-11 kg per pa-sec-m2) or less with openings gasketed or sealed and b. weather stripping has been added on
AND VENTILATION
openable windows and doors and c. caulking or sealants are applied to areas
such as joints around window and door frames, between sole plates and floors, between wall-ceiling joints, between wall panels, at penetrations for plumb- ing, electrical and gas lines and at other openings. If your home meets all of the three criteria above, you must provide additional fresh air. See Ventilation Air From Outdoors, page 7. If your home does not meet all of the three criteria above, proceed to Determining Fresh- Air Flow For Heater Location, page 6.
Todayʼs homes are built more energy efficient than ever. New materials, increased insulation and new construction methods help reduce heat loss in homes. Home owners weather strip and caulk around windows and doors to keep the cold air out and the warm air in. During heating months, home owners want their homes as airtight as possible. While it is good to make your home energy effi- cient, your home needs to breathe. Fresh air must enter your home. All fuel-burning appliances need fresh air for proper combustion and ventilation. Exhaust fans, fireplaces, clothes dryers and fuel burning appliances draw air from the house to operate. You must provide adequate fresh air for these appliances. This will insure proper venting of vented fuel-burning appliances.
Confined and Unconfined Space The National Fuel Gas Code ANSI Z223.1/NFPA 54 defines a confined space as a space whose vol- ume is less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space and an unconfined space as a space whose volume is not less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space. Rooms communicating directly with the space in which the appliances are installed*, through openings not furnished with doors, are considered a part of the unconfined space. * Adjoining rooms are communicating only if there are doorless passageways or ventilation grills between them.
PROVIDING ADEQUATE VENTILATION The following are excerpts from National Fuel Gas Code, ANSI Z223.1/NFPA 54, Section 5.3, Air for Combustion and Ventilation.

Example: 51,200 Btu/Hr (maximum the space can support) 70,000 Btu/Hr (actual amount of Btu/Hr used) The space in the above example is a confined space because the actual Btu/Hr used is more than the maximum Btu/Hr the space can support. You must provide additional fresh air. Your options are as follows: A. Rework worksheet, adding the space of an
Determining if You Have a Confined or Unconfined Space Use this work sheet to determine if you have a confined or unconfined space. Space: Includes the room in which you will install heater plus any adjoining rooms with door- less passageways or ventilation grills between the rooms. 1. Determine the volume of the space (length x width x height). Length x Width x Height = cu. ft. (volume of space) Example: Space size 20 ft. (length) x 16 ft. (width) x 8 ft. (ceiling height) = 2560 cu. ft. (volume of space) If additional ventilation to adjoining room is sup- plied with grills or openings, add the volume of these rooms to the total volume of the space. 2. Multiply the space volume by 20 to determine the maximum Btu/Hr the space can support. (volume of space) x 20 = (maximum Btu/Hr the space can support) Example: 2560 cu. ft. (volume of space) x 20 = 51,200 (maximum Btu/Hr the space can support) 3. Add the Btu/Hr of all fuel burning appliances in the space. Vent-free heater Btu/Hr Gas water heater* Btu/Hr Gas furnace Btu/Hr Vented gas heater Btu/Hr Gas fireplace logs Btu/Hr Other gas appliances* + Btu/Hr Total = Btu/Hr * Do not include direct-vent gas appliances. Direct-vent draws combustion air from the outdoors and vents to the outdoors. Example: Gas water heater Btu/Hr Vent-free heater + Btu/Hr Total = Btu/Hr 4. Compare the maximum Btu/Hr the space can support with the actual amount of Btu/Hr used Btu/Hr (maximum the space can support) Btu/Hr (actual amount of Btu/Hr used)
adjoining room. If the extra space provides an unconfined space, remove door to adjoining room or add ventilation grills between rooms. See Ventilation Air From Inside Building. B. Vent room directly to the outdoors. See Ven-
tilation Air From Outdoors, page 7. C. Install a lower Btu/Hr heater, if lower Btu/Hr
size makes room unconfined. If the actual Btu/Hr used is less than the maxi- mum Btu/Hr the space can support, the space is an unconfined space. You will need no additional fresh air ventilation.
Ventilation Air From Inside Building This fresh air would come from an adjoining un- confined space. When ventilating to an adjoining unconfined space, you must provide two perma- nent openings: one within 12" of the ceiling and one within 12" of the floor on the wall connecting the two spaces (see options 1 and 2, Figure 2, page 7). You can also remove door into adjoining room (see option 3, Figure 2, page 7). Follow the National Fuel Gas Code, ANSI Z223.1/NFPA 54, Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts.
40,000 30,000 70,000

UNPACKING 1. Lift off corrugated box enclosing stove body crating. 2. Remove screws fastening back and top of wood frame enclosure. Two or more people must care- fully lift stove up and out of wooden crate. 3. Remove plastic bag from stove body. 4. Remove back panel from stove (see Figure 4). Use an adjustable wrench or a 10 mm socket. Remove four (4) bolts and washers. Keep bolts and washers to reattach back panel later. 5. Remove bubble-wrapped log set, rod and screen from stove. Remove all protective packaging applied for shipment. 6. Check all items for any shipping damage. If damaged, promptly inform dealer where you bought heater. Some fiber flakes may fall from logs. This is acceptable. 7. Place freestanding stove near desired location in room.

Figure 2 - Ventilation Air from Inside
Top of Wood Frame Enclosure
Ventilation Air From Outdoors Provide extra fresh air by using ventilation grills or ducts. You must provide two permanent openings: one within 12" of the ceiling and one within 12" of the floor. Connect these items directly to the outdoors or spaces open to the outdoors. These spaces include attics and crawl spaces. Follow the National Fuel Gas Code, ANSI Z223.1/NFPA 54, Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts. IMPORTANT: Do not provide openings for inlet or outlet air into attic if attic has a thermostat- controlled power vent. Heated air entering the attic will activate the power vent.


Figure 4 - Unpacking Stove from Wooden
Figure 3 - Ventilation Air from Outdoors

NOTICE: This heater is intended for use as supplemental heat. Use this heater along with your primary heating system. Do not install this heater as your pri- mary heat source. If you have a central heating system, you may run system’s circulating blower while using heater. This will help circulate the heat throughout the house. In the event of a power outage, you can use this heater as your primary heat source.
CHECK GAS TYPE Use the correct gas type (natural or propane/LP) for your unit. If your stove heater gas type is different from your house gas type, do not install heater. Call dealer where you bought heater for proper type heater.
CLEARANCES TO COMBUSTIBLES (Vent-Free Operation Only)
Carefully follow the instructions below. This stove is a freestanding unit designed to set directly on the floor. DO NOT place stove directly on carpeting, vinyl tile or any combustible material other than wood. The stove must be set on a metal or wood panel extending the full width and depth of the stove for these floor coverings. Important: You must maintain minimum wall and ceiling clear- ances during installation. The minimum clearances are shown in Figure 5, page 9. Measure from outermost point of stove top.
Minimum Wall and Ceiling Clearances (see Figure 5, page 9) A. Clearances from outermost point of stove top
to any combustible side wall should not be less than 12 inches. B. Clearances from outermost point of stove top
to any combustible back wall should not be less than 6 inches (includes corner installations). C. Clearances from the stove top to the ceiling
should not be less than 48 inches.



Front of Stove Unit
Figure 5 - Minimum Clearance to Walls and Ceiling (Stove May Vary Depending
Side View · on Model)


For propane/LP units, the installer must supply an external regulator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11 and 14 inches of water. If you do not reduce incoming gas pres- sure, heater regulator damage could occur. Install external regulator with the vent pointing down as shown in Figure 7. Pointing the vent down protects it from freezing rain or sleet.
We recommend that you install a sediment trap in supply line as shown in Figure 8. Locate sediment trap where it is within reach for cleaning. Install in piping system between fuel supply and heater. Locate sediment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into heater controls. If sediment trap is not installed or is installed wrong, heater may not run properly.

Installation must include an equipment shutoff valve, union and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from heater (see Figure 8). IMPORTANT: Install equipment shutoff valve in an accessible location. The equipment shutoff valve is for turning on or shutting off the gas to the appliance. Check your building codes for any special re- quirements for locating equipment shutoff valve to fireplaces. Apply pipe joint sealant lightly to male NPT threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged heater valves.
Figure 7 - External Regulator For Propane/LP Gas With Vent Pointing Down
From External Regulator (11" W.C.** to 14" W.C. Pressure)
CSA Design- Certified Equipment Shutoff Valve With 1/8" NPT Tap*

Approved Flexible Gas Hose (if allowed by local codes)
Gas Inlet Connection Access
Figure 8 - Gas Connection
* Purchase the optional CSA design-certified equipment shutoff valve from your dealer. See Accessories, page 19. ** Minimum inlet pressure for purpose of input adjustment.
Figure 6 - Gas Regulator Location and
Gas Line Access Into Stove Cabinet
Product Identification Label · Gas Log Heater

Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa) 1. Close equipment shutoff valve (see Figure 9). 2. Pressurize supply piping system by either opening propane/LP supply tank valve for propane/LP gas or opening main gas valve located on or near gas meter for natural gas or using compressed air. 3. Check all joints from gas meter for natural or propane/LP supply to equipment shutoff valve (see Figure 10 or Figure 11, page 10). Apply noncorrosive leak detection fluid to gas joints. Bubbles forming show a leak. 4. Correct all leaks at once.

Figure 9 - Equipment Shutoff Valve
PRESSURE TESTING HEATER GAS CONNECTIONS 1. Open equipment shutoff valve (see Figure 9). 2. Open main gas valve located on or near gas meter for natural gas or open propane/LP supply tank valve. 3. Make sure control knob of heater is in the OFF position. 4. Check all joints from equipment shutoff valve to control valve (see Figure 10 or Figure 11, page 12). Apply noncorrosive leak detection fluid to gas joints. Bubbles forming show a leak. 5. Correct all leaks at once. 6. Light heater (see Operating Heater, page 13). Check all other internal joints for leaks. 7. Turn off heater (see To Turn Off Gas to Appli- ance, page 14).
Test Pressures In Excess Of 1/2 PSIG (3.5 kPa) 1. Disconnect appliance with its appliance main gas valve (control valve) and equipment shutoff valve from gas supply piping system. Pressures in excess of 1/2 psig will damage heater regulator. 2. Cap open end of gas pipe where equipment shutoff valve was connected. 3. Pressurize supply piping system by either opening propane/LP supply tank valve for propane/LP gas or opening main gas valve located on or near gas meter for natural gas or using compressed air. 4. Check all joints of gas supply piping system. Apply noncorrosive leak detection fluid to gas joints. Bubbles forming show a leak. 5. Correct all leaks at once. 6. Reconnect heater and equipment shutoff valve to gas supply. Check reconnected fit- tings for leaks.

Figure 10 - Checking Gas Joints on

INSTALLING LOG SET 1. Set one-piece log on heater base as shown in Figure 14. Make sure middle section at bot- tom of log is seated into "U" shaped cutout in center of heater base. Log will fit securely on base. IMPORTANT: Make sure log does not cover any burner ports and does not touch the stove cavity (see Figure 14). 2. Fasten back panel to stove with four (4) bolts and washers removed in step 4 of Unpacking, page 7. Make sure product identification label is located on the outside lower left-hand corner. 3. Place freestanding stove in desired position being careful not to damage gas connections. Be sure to maintain clearances to combustibles and wall clearances as outlined on page 8.

Figure 11 - Checking Gas Joints on
INSTALLING ROD AND SCREEN 1. Insert rod through small rings located at top of screen (see Figure 12). 2. From back of stove, insert rod into hole located inside right front of stove as shown in Figure 13. 3. Slip left side of rod down into slot on inside left front of stove (see Figure 13).

Middle Section at Bottom of Log Set

"U" Shaped Cutout in Chassis
Figure 14 - Installing One-Piece Stove
Burner Porting Areas (double slotted rectangular openings
Figure 12 - Assembling Rod and Screen

Slot on Inside Left Front of Stove
Hole on Inside Right Front of Stove
Rod with Screen Assembled

Figure 15 - Top View of One-Piece Log
Set on Gas Log Heater
Figure 13 - Installing Screen Into Stove
(View From Back of Stove)

4. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information, column 1. If you donʼt smell gas, go to the next step. 5. Turn control knob counterclockwise to the PILOT position. Press in control knob for five (5) seconds (see Figure 16). Note: You may be running this heater for the first time after hooking up to gas sup- ply. If so, the control knob may need to be pressed in for 30 seconds or more. This will allow air to bleed from the gas system. 6. With control knob pressed in, press and release ignitor button. This will light pilot. The pilot is attached to the front burner. If needed, keep pressing ignitor button until pilot lights. Note: If pilot does not stay lit, contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure, page 14. 7. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. • If control knob does not pop out when released, contact a qualified service person or gas supplier for repairs. Note: If pilot goes out, repeat steps 3 through 7. This heater has a safety interlock system. Wait one (1) minute for system to reset before lighting pilot again. 8. Turn control knob counterclockwise to desired heating level. The burners should light. Set control knob to any heat level between HI and LO.
A. This appliance has a pilot which must be
lighted by hand. When lighting the pilot, follow these instructions exactly. B. BEFORE LIGHTING smell all around the
gas control knob. Never use tools. If the knob will not push in or turn by hand, donʼt try to repair it, call a qualified service tech- nician or gas supplier. Force or attempted repair may result in a fire or explosion. D. Do not use this appliance if any part has been
under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.
Control Knob Ignitor Button
Figure 16 - Control Knob and Ignitor
Figure 17 - Pilot
Button Location · Thermocouple · Pilot Burner

TO APPLIANCE
Shutting Off Heater Turn control knob clockwise to the OFF position.
Figure 18 - Correct Pilot Flame Pattern
Shutting Off Burners Only (pilot stays lit) Turn control knob clockwise to the PILOT position.
OPERATION The thermostat control knob can be set to any comfort level between HI and LO. The ther- mostat will gradually modulate the heat output and flame height from higher to lower settings or pilot, in order to maintain the comfort level you select. The ideal comfort setting will vary by household depending upon the amount of space to be heated, the output of the central heating system, etc. Note: Selecting the HI setting with the control knob will cause the burner to remain fully on, without modulating down in most cases.
Figure 19 - Incorrect Pilot Flame Pattern
MAIN BURNER Periodically inspect all burner flame holes with the heater running. All slotted burner flame holes should be open with yellow flame present. All round burner flame holes should be open with a small blue flame present. Some burner flame holes may become blocked by debris or rust, with no flame present. If so, turn off heater and let cool. Remove blockage. Blocked burner flame holes will create soot.
PROCEDURE 1. Follow steps 1 through 5 under Lighting Instructions, page 13. 2. Depress control knob and light pilot with match. 3. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Now follow step 8 in Lighting Instructions, page 13.
MAINTENANCE
INSPECTING BURNERS Check pilot flame pattern and burner flame pat- terns often.

Injector Holder (May Be Brass or Aluminum Depending on Model)
BURNER INJECTOR HOLDER AND PILOT AIR INLET HOLE The primary air inlet holes allow the proper amount of air to mix with the gas. This provides a clean burning flame. Keep these holes clear of dust, dirt, lint and pet hair. Clean these air inlet holes prior to each heating season. Blocked air holes will create soot. We recommend that you clean the unit every three months during operation and have heater inspected yearly by a qualified service person. We also recommend that you keep the burner tube and pilot assembly clean and free of dust and dirt. To clean these parts we recommend us- ing compressed air no greater than 30 PSI. Your local computer store, hardware store or home center may carry compressed air in a can. You can use a vacuum cleaner in the blow position. If using compressed air in a can, please follow the directions on the can. If you don't follow directions on the can, you could damage the pilot assembly. Note: Removing the rear panel and top grates of your stove will make cleaning easier. 1. Shut off the unit, including the pilot. Allow the unit to cool for at least thirty minutes. 2. Inspect burner, pilot and primary air inlet holes on injector holder for dust and dirt (see Figure 20). 3. Blow air through the ports/slots and holes in the burner. 4. Check the injector holder located at the end of the burner tube again. Remove any large particles of dust, dirt, lint or pet hair with a soft cloth or vacuum cleaner nozzle. 5. Blow air into the primary air holes on the injector holder. 6. In case any large clumps of dust have now been pushed into the burner repeat steps 3 and 4. Clean the pilot assembly also. A yellow tip on the pilot flame indicates dust and dirt in the pilot as- sembly. There is a small pilot air inlet hole about two inches from where the pilot flame comes out of the pilot assembly (see Figure 21). With the unit off, lightly blow air through the air inlet hole. You may blow through a drinking straw if compressed air is not available.
Primary Air Inlet Holes (Shape of Holes May Vary by Model)
Figure 20 - Injector Holder On Outlet
Pilot Air Inlet Hole
Figure 21 - Pilot Inlet Air Hole

POSSIBLE CAUSE
REMEDY
When ignitor button is pressed, there is no spark at ODS/pilot
When ignitor button is pressed, there is spark at ODS/pilot but no ignition
ODS/pilot lights but flame goes out when control knob is re- leased

POSSIBLE CAUSE
REMEDY
Burner does not light after ODS/ pilot is lit
Burner backfiring during com- bustion
Slight smoke or odor during initial operation
Moisture/condensation noticed on windows
Heater produces a whistling noise when burner is lit
Dark residue on logs or inside of fireplace
White powder residue forming within burner box or on adjacent walls or furniture
Delayed ignition burner

POSSIBLE CAUSE
REMEDY
Heater produces a clicking/tick- ing noise just after burner is lit or shut off
Heater produces unwanted odors
Heater shuts off in use (ODS operates)
Gas odor even when control knob is in OFF position
Gas odor during combustion

CSBPT, CSPBPT, CSPIPT (Includes 111485-01 Burner Chassis)
Btu (Variable) 16,000/30,000 Type Gas Propane/LP Only Ignition Piezo Pressure Manifold 8" W.C. Inlet Gas Pressure (in. of water) Maximum 14" Minimum* 11" Shipping Weight 265 lbs. * For input adjustment
CSBNT, CSPBNT, CSPINT (Includes 111485-02 Burner Chassis)
Btu (Variable) 16,000/30,000 Type Gas Natural Gas Only Ignition Piezo Pressure Manifold 3.5" W.C. Inlet Gas Pressure (in. of water) Maximum 10.5" Minimum* 5" Shipping Weight 265 lbs.
* For input adjustment
ACCESSORIES Purchase these heater accessories from your local dealer. If they can not supply these accessories, call DESA Heating Products at 1-866-672-6040 for referral information. You can also write to the address listed on the back page of this manual.
TECHNICAL SERVICE You may have further questions about installation, operation or troubleshooting. If so, contact DESA Heating Productsʼ Technical Service Department at 1-866-672-6040. When calling, please have your model and serial numbers of your heater ready. You can also visit DESA Heating Productsʼ techni- cal service web site at www.desatech.com.
EQUIPMENT SHUTOFF VALVE GA5010 For all models. Equipment shutoff valve with 1/8" NPT tap. Fits 1/2" NPT pipe.
CLEANING KIT - CCK (Not Shown) For all models. Your vent-free gas appliance re- quires regular cleaning and maintenance to prevent performance problems. This kit gives you the tools and instructions to make it easy to clean all critical areas of your appliance.
REPLACEMENT PARTS Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.
INFORMATION VIDEO - 108917-01 For all models. A care and maintenance video is avail- able by calling 1-866-672-6040. You may also email your request to productsupport@desaint.com.



PARTS LIST This list contains replaceable parts used in your stove. For replacement parts see Replacement Parts on page 19 of this manual.
NO. 111485-01 111485-02 DESCRIPTION QTY
1 104026-01 104026-01 Stove Log 1 2 098249-01 098249-01 Nut, M5 2 3 ** ** Painted Base Assembly 1 4 104454-01 104454-01 Bracket, Regulator 1 5 098867-10 098867-14 Gas Regulator 1 6 104425-01 104425-01 Inlet Tube 1 7 104424-03 104424-03 Outlet Burner Tube 1 8 099056-19 099056-26 Burner Orifice Injector 1 9 111124-01 111124-01 Burner Retainer Spring 1 10 102980-01 102980-01 Burner 1 11 101329-22 101329-21 Control Valve 1 12 104472-01 104472-01 Bracket 1 13 099211-01 099211-01 Screw 2 14 102445-01 102445-01 Piezo Ignitor 1 15 099387-09 099387-09 Pilot Tube 1 16 098271-10 098271-10 Ignitor Cable 1 17 104286-01 104285-01 ODS Pilot 1 18 M11084-38 M11084-38 Screw, Hex Head (#8-18 x .38) 7
100563-01 100563-01 Warning Plate 1 101054-01 101054-01 Lighting Instructions Plate 1 100565-01 100565-01 Warning Plate Fastener 1 101137-04 101137-04 Hardware Kit 1
** Not a field replaceable part.



PARTS LIST This list contains replaceable parts used in your stove. For replacement parts see Replacement Parts on page 19 of this manual.
PART NUMBER KEY CSB Series CSPB Series CSPI Series NO. (Black) (Porcelain Black) (Porcelain Ivory) DESCRIPTION QTY. 1 111698-07 111698-08 111698-09 Top Grate - Center 1 2 111698-11 111698-12 111698-13 Bottom Door 1 3 111531-01CK 111531-01CK 111531-01CK Stove Dropped Pan (Black Only) 1 4 111698-14 111698-15 111698-16 Left Stove Door 1 5 111698-17 111698-18 111698-19 Right Stove Door 1 6 111698-20 111698-21 111698-22 Stove Leg 4 7 111764-01 111764-01 111764-01 Hardware Kit 1 8 111533-01 111533-01 111533-01 Screen Rod 1 9 111532-01CK 111532-01CK 111532-01CK Stove Back Panel (Black Only) 1 10 111698-23 111698-23 111698-23 Door Knob 1 11 103297-04 103297-04 103297-04 Screen 1
104108-08 ——— ——— Touch-up Spray Paint 12 oz Can, Black 1
* Included In Hardware Kit
PARTS CENTRALS These Parts Centrals are privately owned businesses. They have agreed to support our customerʼs needs by providing original replacement parts and accessories
Tool & Equipment Company 5 Manila Ave. Hamden, CT 06514-0322 1-800-397-7553 203-248-7553
Master Parts Dist. 1251 Mound Ave NW Grand Rapids, MI 49504-2672 616-791-0505 1-800-446-1446 Fax: 616-791-8270 www.nbmc.com
Laporte’s Parts & Service 2444 N. 5th Street Hartsville, SC 29550-7704 843-332-0191 Parts Department
Portable Heater Parts 342 N. County Rd. 400 East Valparaiso, IN 46383-9704 All States 219-462-7441 1-888-619-7060 www.portableheaterparts.com sales@portableheaterparts.com techservice@portableheaterparts.com
Cans Unlimited, Inc. P.O. Box 645 Taylor, SC 29687-0013 All States 803-879-3009 1-800-845-5301 cuisales@aol.com
Washer Equipment Co. 1715 Main Street Kansas City, MO 64108-2195 KS, MO, AR 816-842-3911 www.washerparts.com
East Coast Energy Products 707 Broadway W. Long Branch, NJ 07764-1542 732-870-8809 1-800-755-8809 www.njplaza.com/ecep
FBD 1349 Adams Street Bowling Green, KY 42103-3414 270-846-1199 1-800-654-8534 Fax: 1-800-846-0090 franktalk@aol.com
21st Century 2950 Fretz Valley Road Perkasie, PA 18944-4034 215-795-0400 800-325-4828

Serial No.
Always specify model and serial numbers when communicating with the factory.
We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty. We make no other warranty, expressed or implied.
LIMITED WARRANTY VENT-FREE PROPANE/LP GAS OR NATURAL GAS LOG HEATERS AND CAST IRON STOVE CHASSIS
DESA Heating Products warrants this product to be free from defects in materials and components for two (2) years from the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions. To make a claim under this warranty the Bill of Sale or cancelled check must be presented.
This warranty is extended only to the original retail purchaser. This warranty covers only the cost of part(s) required to restore this heater to proper operating condition. Warranty part(s) MUST be obtained through authorized dealers of this product and/or DESA Heating Products who will provide original factory replacement parts. Failure to use original factory replacement parts voids this warranty. The heater MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit.
This warranty does not apply to parts that are not in original condition because of normal wear and tear or parts that fail or become damaged as a result of misuse, accidents, lack of proper maintenance or defects caused by improper installation. Travel, diagnostic cost, labor, transportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner.
TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT; THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND LIMITS THE DURATION OF ANY AND ALL IMPLIED WARRANTIES, INCLUD- ING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO TWO (2) YEARS FROM THE DATE OF FIRST PURCHASE; AND DESA HEATING PRODUCTSʼ LIABILITY IS HEREBY LIMITED TO THE PURCHASE PRICE OF THE PRODUCT AND DESA HEATING PRODUCTS SHALL NOT BE LIABLE FOR ANY OTHER DAMAGES WHATSOEVER INCLUDING INDIRECT, INCI- DENTAL OR CONSEQUENTIAL DAMAGES.
Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of incidental or consequential damages, so the above limitation on implied warranties or exclusion or limitation on damages may not apply to you.
This warranty gives you specific legal rights and you may also have other rights that vary from state to state.
For information about this warranty write:
2701 Industrial Drive P.O. Box 90004 Bowling Green, KY 42102-9004 www.desatech.com