Copyright © 2015 Dell Inc. All rights reserved. This product is protected by U.S. and international copyright and intellectual property laws. Dell™ and the Dell logo are trademarks of Dell Inc. in the United States and/or other jurisdictions. All other marks and names mentioned herein may be trademarks of their respective companies.
Rev. A00






The Dell XC730xd system is web-scale converged appliance based on the Dell PowerEdge R730xd that supports two Intel Xeon E5-2600 v3 processors, up to 24 DIMMs, and 24 hard drives/SSDs.
Up to twelve 3.5 inch hard drives.
Twenty four hard-drive systems
Up to twenty-four 2.5 inch hard drives.

Figure 1. Front panel features and indicators (2.5 inch hard drive/SSD chassis)
Systems Configurations · Twelve hard-drive systems


Figure 2. Front panel features and indicators (3.5 inch hard drive chassis)

The diagnostic indicators on the system front panel display error status during system startup.
Table 1. Diagnostic indicators



Figure 3. Hard drive indicators

Figure 4. HDD indicators on the hard-drive tray backplane

Table 2.
Drive-status indicator pattern Condition
Blinks green two times per second Identifying drive or preparing for removal. HDD or SSD location is enabled or one of more HDDs or SSDs is in the failed state on the Nutanix Web GUI.
Off Drive ready for insertion or removal.
Blinks green, amber, and turns off Predicted drive failure
Blinks amber four times per second Drive failed
Blinks green slowly Drive rebuilding
Steady green Drive online
Blinks green three seconds, amber three seconds, and turns off six seconds

Figure 5. iDRAC Direct LED indicator
The table below displays iDRAC Direct activity when configuring iDRAC Direct by using the management port (USB XML Import).
Rebuild aborted

Table 3. iDRAC Direct by using the management port (USB XML Import).
Convention iDRAC Direct LED indicator pattern
A Green Lights green for a minimum of 2 seconds at the beginning and end of a file transfer.
B Flashing green Indicates file transfer or any operation tasks.
C Green and turns off
Indicates that the file transfer is complete.
D Not lit Indicates that the USB is ready to be removed or that a task is complete.
The table below displays iDRAC Direct activity when configuring iDRAC Direct using your laptop and cable (Laptop Connect).
Table 4. iDRAC Direct using your laptop and cable (Laptop Connect).
iDRAC Direct LED indicator pattern
Solid green for two seconds
Indicates that the laptop is connected.
Flashing green (on for two seconds and off for two seconds)
Indicates that the laptop connected is recognized.
Turns off Indicates that the laptop is unplugged.
Item Indicator, button, or connector
1 System identification button
You can use the identification buttons on the front to locate a particular system within a rack. When one of these buttons is pressed, the system status indicator on the back flashes until one of the buttons is pressed again.
Press to toggle the system ID on and off. If the system stops responding during POST, press and hold the system ID button for more than five seconds to enter the BIOS progress mode.
Condition · Condition · Icon Description

Item Indicator, button, or connector
To reset iDRAC (if not disabled in F2 iDRAC setup) press and hold the button for more than 15 seconds.
2 System identification connector
Connects the optional system status indicator assembly through the optional cable management arm.
3 iDRAC8 Enterprise port
Dedicated management port for iDRAC8.
4 Half-height PCIe expansion-card slot (3)
Allows you to connect up to three half- height PCI Express expansion cards.
Allows you to connect a serial device to the system.
Allows you to connect a VGA display to the system.
7 USB connector (2)
Allows you to connect USB devices to the system. The ports are USB 3.0- compliant.
8 Full-height PCIe expansion-card slot (3)
Allows you to connect up to three full- height PCI Express expansion cards. These are reserved for Dell PERC H310 and LSI 9207-8i.
9 Ethernet connector (4)
Four integrated 10/100/1000 Mbps NIC connectors
Four integrated connectors that include:
10 Power supply unit (PSU1) AC 495 W, 750 W, or 1100 W
11 Power supply unit (PSU2)
DC 495 W, 750 W, or 1100 W
12 vFlash media card slot
Allows you to insert a vFlash media card.
13 Two HDD blanks


Figure 6. NIC indicators
A Link and activity indicators are off The NIC is not connected to the network.
B Link indicator is green The NIC is connected to a valid network at its maximum port speed (1 Gbps or 10 Gbps).
C Link indicator is amber The NIC is connected to a valid network at less than its maximum port speed.
D Activity indicator is blinking green Network data is being sent or
received.
Each AC power supply unit (PSU) has an illuminated translucent handle and each DC power supply unit (when available) has an LED that serves as an indicator to show whether power is present or a power fault has occurred.
Indicator Indicator code


Figure 7. AC power supply unit status indicator
Table 5. AC Power indicator
Convention Power indicator pattern
A Green The handle indicator lights green indicating that a valid power source is connected to the power supply unit and that the power supply unit is operational.
B Flashing green When updating the firmware of the power supply unit, the power supply unit handle flashes green.
C Flashing green and turns off
When hot-adding a power supply unit (PSU), the power supply unit handle flashes green five times at 4 Hz rate and turns off. This indicates that the power supply unit is mismatched with the other power supply unit (in terms of efficiency, feature set, health status, and supported voltage). Replace the power supply unit that has the flashing indicator with a power supply unit that matches the capacity of the other installed power supply unit.
D Flashing amber Indicates a problem with the power supply unit.
Condition

Convention Power indicator pattern
E Not lit Power is not connected.

Figure 8. DC power supply unit status indicator
Condition

Table 6. DC Power indicator
Convention Power indicator pattern
A Green The handle/LED indicator lights green indicating that a valid power source is connected to the power supply unit and that the power supply unit is operational.
B Flashing green When hot-adding a power supply unit, power supply unit LED flashes green. This indicates that the power supply unit is mismatched with the other power supply unit (in terms of efficiency, feature set, health status, and supported voltage). Replace the power supply unit that has the flashing indicator with a power supply unit that matches the capacity of the other installed power supply unit.
C Flashing amber Indicates a problem with the power supply unit.
D Not lit Power is not connected.
The documentation matrix provides information about the documents you use to configure and deploy the Dell web-scale converged appliance solution.
Make sure that you read through any media that ships with your system that provides documentation and tools for configuring and managing your system, including those pertaining to the OS, system management software, system updates, and system components that you purchased with your system.
Condition

For the full name of an abbreviation or acronym used in this document, see the Glossary at dell.com/ support/home.
The following tables list the documents provided by Dell and Nutanix.
Dell documentation is either included with your shipment or available at the Dell website at dell.com/ xcseriesmanuals.
Dell documentation for:
To access Dell documentation:
Table 7. Dell reference documentation for the Dell XC730xd Web-scale Converged Appliance
To learn about… Refer to…
Setup instructions of your Dell XC730xd, including the technical specifications
Hardware details of your Dell XC730xd Owner’s Manual
How to install your Dell XC730xd in a rack Dell Rack Install Guide
How to deploy and set up this solution Solutions Guide
Setting up and using Dell iDRAC 8 Dell iDRAC 8 Quick Start Guide
Using OpenManage Essentials to monitor, perform updates, view hardware, and view inventory on your system
Dell OpenManage Essentials User’s Guide
Most Nutanix documentation is available at https://portal.nutanix.com/#/page/docs on the Nutanix Documents page. However, two documents are available behind the Nutanix document portal. Nutanix documentation is listed by version, category, and type. Make sure that you select the appropriate version of documentation for this release, which is 4.0 or later. Or refer to the Nutanix OS to find corresponding documentation support.
To access most Nutanix documentation:
Getting Started Guide

To access the NOS Advanced Administration Guide and Advanced Setup Guide:
Table 8. Nutanix reference documentation
To learn about… Refer to…
Setup instructions for your solution. Setup Guide
Setup instructions for environments with special requirements and restrictions
Instructions and reference for administering the Nutanix Operation System (NOS) outside the Nutanix Prism UI (such as cluster start/stop, manual upgrade, changing passwords, reconfiguring IP addresses, and troubleshooting tools).
NOS Advanced Administration Guide
Comprehensive instructions and references for the Nutanix UI, including overview information.
Managing VMware ESXi hosts that run NOS, including VMware vCenter requirements.
Managing Hyper-V hosts that run NOS. Hyper-V Administration Guide
Comprehensive references for the Nutanix REST API.
Comprehensive references for Controller Virtual Machine (CVM) utilities, nCLI commands, and Nutanix PowerShell cmdlets.
Software instructions for hardware components that are not functioning.
Use the Quick Resource Locator (QRL) to get immediate access to system information and how-to videos. This can be done by visiting dell.com/QRL or by using your smartphone or tablet and a model specific Quick Resource (QR) code located on your Dell system. To try out the QR code, scan the following image.


Figure 9. Quick Resource Locator

After you receive your system, you must set up your system, install the operating system if it is not pre- installed, and set up and configure the system iDRAC IP address.
You can set up the Integrated Dell Remote Access Controller (iDRAC) IP address by using one of the following interfaces:
You can configure iDRAC IP using:
For more information on setting up and configuring iDRAC, see the Integrated Dell Remote Access Controller User's Guide at dell.com/esmmanuals
For more information, see the RACADM Command Line Interface Reference Guide and the Integrated Dell Remote Access Controller User's Guide.
You can log in to iDRAC as an iDRAC local user, a Microsoft Active Directory user, or a Lightweight Directory Access Protocol (LDAP) user. You can also log in by using Single Sign-On or a Smart Card. The

default user name is root and password is calvin. For more information on logging in to iDRAC and iDRAC licenses, see the Integrated Dell Remote Access Controller User's Guide at dell.com/esmmanuals
You can also access iDRAC using RACADM. For more information, see the RACADM Command Line Interface Reference Guide and the Integrated Dell Remote Access Controller User's Guide available at dell.com/esmmanuals
If the server is shipped without an operating system, install the supported operating system on the server by using one of the following methods:
For information on the list of operating systems supported on your system, see the operating systems support matrix at dell.com/ossupport
To perform out-of-band systems management using iDRAC, you must configure iDRAC for remote accessibility, set up the management station and managed system, and configure the supported Web browsers. For more information, see the Integrated Dell Remote Access Controller User’s Guide at dell.com/esmmanuals
You can also remotely monitor and manage the server by using the Dell OpenManage Server Administrator software and OpenManage Essentials systems management console. For more information, see dell.com/openmanagemanuals
Dell recommends that you download and install the latest BIOS, drivers, and systems management firmware on your system.
Ensure that you clear the web browser cache.
Steps 1. Go to Support.Dell.com.
The drivers that are applicable to your selection are displayed.

The pre-operating system management applications for your system helps you manage different settings and features of your system without booting to the operating system.
Your system has the following pre-operating system management applications:
Dell Lifecycle Controller allows you to perform useful tasks such as configuring BIOS and hardware settings, deploying operating system, updating drivers, and saving hardware profiles. For more information about Dell Lifecycle Controller, see the documentation at dell.com/esmmanuals
The navigation keys can help you access the pre-operating system management applications.
Table 9. Navigation keys
Page Up Moves to the previous screen.
Page Down Moves to the next screen.
Up arrow Moves to the previous field.
Moves to the next field.
Enter Enables you to type a value in the selected field (if applicable) or follow the link in the field.
Spacebar Expands or collapses a drop-down list, if applicable.
Tab Moves to the next focus area.
Esc Moves to the previous page until you view the main screen. Pressing Esc in the main screen exits System BIOS/iDRAC Settings/Device Settings/Service Tag Settings and proceeds with system boot.
F1 Displays the System Setup help.
F2 Enables you to enter System Setup
Key Description · Down arrow

F10 Enables you to enter Lifecycle Controller
F11 Enables you to enter Boot Manager
F12 Enables you to enter PXE boot
Using System Setup, you can configure the BIOS settings, iDRAC settings, and device settings of your system.
You can access System Setup in two ways:
To enable Console Redirection:
From System Setup, you can:
If your operating system begins to load before you press F2, allow the system to finish booting, and then restart your system and try again.
Key Description

Table 10. System setup main menu
System BIOS Enables you to configure BIOS settings.
iDRAC Settings Enables you to configure iDRAC settings.
The iDRAC Settings utility is an interface to set up and configure the iDRAC parameters by using UEFI. You can enable or disable various iDRAC parameters by using the iDRAC Settings utility. For more information about this utility, see the Integrated Dell Remote Access Controller User’s Guide at dell.com/esmmanuals
Device Settings Enables you to configure device settings.
You can use the System BIOS screen to view the BIOS settings. You can also edit some of the settings such as Boot Order, System Password, Setup Password, and enable or disable USB ports.
Go to System Setup Main Menu, and then click System BIOS.
The System BIOS screen is displayed.
System BIOS screen settings
The System BIOS screen details are explained below.
Table 11. System BIOS
System Information Displays information about the system such as the system model name, BIOS version and Service Tag.
Memory Settings Displays information and options related to the installed memory.
Processor Settings Displays information and options related to the processor such as speed, cache size, and so on.
SATA Settings Displays options to enable or disable the integrated SATA controller and ports.
Boot Settings Displays options to specify the boot mode (BIOS or UEFI). Enables you to modify UEFI and BIOS boot settings.
Network Settings Displays options to change the network settings.
Integrated Devices Displays options to enable or disable integrated device controllers and ports, and to specify related features and options.
Serial Communication Displays options to enable or disable the serial ports and specify related features and options.
System Profile Settings Displays options to change the processor power management settings, memory frequency, and so on.
System Security Displays options to configure the system security settings like, system password, setup password, Trusted Platform Module (TPM) security, and
Option Description · Menu Item Description

so on. It also enables or disables support for the power and NMI buttons on the system.
Miscellaneous Settings Displays options to change the system date, time, and so on.
You can use the System Information screen to view system properties such as Service Tag, system model, and the BIOS version.
The System Information screen is displayed.
System information screen settings
The System Information screen details are explained as follows:
Table 12. System information
System Model Name Displays the system model name.
System BIOS Version Displays the BIOS version installed on the system.
System Management Engine Version
Displays the current revision of the Management Engine firmware.
System Service Tag Displays the system Service Tag.
System Manufacturer Displays the name of the system manufacturer.
System Manufacturer Contact Information
Displays the contact information of the system manufacturer.
System CPLD Version Displays the current revision of the system CPLD firmware.
UEFI Compliance Version Displays the system firmware UEFI compliance level.
You can use the Memory Settings screen to view all the memory settings. You can also enable or disable some memory configurations such as system memory testing and node interleaving.
The Memory Settings screen displays..
The Memory Settings screen details are explained as follows:
Menu Item Description · Menu Item Description · Memory screen settings

Table 13. Memory settings
System Memory Size Displays the amount of memory installed in the system.
System Memory Type Displays the type of memory installed in the system.
System Memory Speed Displays the system memory speed.
System Memory Voltage Displays the system memory voltage.
Video Memory Displays the amount of video memory.
System Memory Testing Specifies whether system memory tests are run during system boot. Options are Enabled and Disabled. By default, the System Memory Testing option is set to Disabled.
Memory Operating Mode Specifies the memory operating mode. The options available are Optimizer Mode, Advanced ECC Mode, Mirror Mode, Spare Mode, Spare with Advanced ECC Mode, and Dell Fault Resilient Mode. By default, the Memory Operating Mode option is set to Optimizer Mode.
Node Interleaving Specifies if Non-Uniform Memory architecture (NUMA) is supported. If this field is Enabled, memory interleaving is supported if a symmetric memory configuration is installed. If Disabled, the system supports NUMA (asymmetric) memory configurations. By default, Node Interleaving option is set to Disabled.
Snoop Mode Specifies the Snoop Mode options. Snoop Mode options available are Home Snoop, Early Snoop, Cluster on Die. By default, the Snoop Mode option is set to Early Snoop. The field is only available when Node Interleaving is Disabled.
You can use the Processor Settings screen to view the processor settings. You can also enable virtualization technology, hardware prefetcher, and logical processor idling.
The Processor Settings screen displays.
The Processor Settings screen details are explained as follows:
Menu Item Description · Processor settings screen

Table 14. Processor settings
Logical Processor Enables or disables the logical processors and displays the number of logical processors. If the Logical Processor option is set to Enabled, the BIOS displays all the logical processors. If this option is set to Disabled, the BIOS only displays one logical processor per core. By default, the Logical Processor option is set to Enabled.
Alternate RTID (Requestor Transaction ID) Setting
Enables you to allocate more RTIDs to the remote socket, thereby increasing cache performance between the sockets or easing work in normal mode for NUMA. By default, the Alternate RTID (Requestor Transaction ID) Setting is set to Disabled.
Virtualization Technology Enables or disables the additional hardware capabilities provided for virtualization. By default, the Virtualization Technology option is set to Enabled.
Address Translation Service (ATS)
Defines the Address Translation Cache (ATC) for devices to cache the DMA transactions. This field provides an interface to a chipset's Address Translation and Protection Table to translate DMA addresses to host addresses. By default, the option is set to Enabled.
Adjacent Cache Line Prefetch
Optimizes the system for applications that require high usage of sequential memory access. By default, the Adjacent Cache Line Prefetch option is set to Enabled. You can disable this option for applications that require high usage of random memory access.
Hardware Prefetcher Enables or disables the hardware prefetcher. By default, the Hardware Prefetcher option is set to Enabled.
DCU Streamer Prefetcher Allows you to enable or disable the Data Cache Unit (DCU) streamer prefetcher. By default, the DCU Streamer Prefetcher option is set to Enabled.
DCU IP Prefetcher Enables or disables the Data Cache Unit (DCU) IP prefetcher. By default, the DCU IP Prefetcher option is set to Enabled.
Execute Disable Enables or disables the execute disable memory protection technology. By default, the Execute Disable option is set to Enabled.
Logical Processor Idling Enables or disables the operating system capability to put logical processors in the idling state in order to reduce power consumption. By default, the option is set to Disabled.
Configurable TDP Allows reconfiguration of Thermal Design Power (TDP) to lower levels. TDP refers to the maximum amount of power the cooling system is required to dissipate.
X2Apic Mode Enables or disables the X2Apic mode.
Controls the turbo engagement. Enable this option only when System Profile is set to Performance.
Number of Cores per Processor
Controls the number of enabled cores in each processor. By default, the Number of Cores per Processor option is set to All.
Processor 64-bit Support Specifies if the processor(s) support 64-bit extensions.
Menu Item Description · Dell Controlled Turbo

Processor Core Speed Displays the maximum core frequency of the processor.
You can use the SATA Settings screen to view the SATA settings of SATA devices and enable RAID on your system.
The SATA Settings screen displays.
The SATA Settings screen details are explained below.
Table 15. SATA settings
Embedded SATA Enables the embedded SATA to be set to Off, ATA, AHCI, or RAID modes. By default, the Embedded SATA option is set to AHCI.
Security Freeze Lock Sends Security Freeze Lock command to the Embedded SATA drives during POST. This option is applicable only to ATA and AHCI mode.
Write Cache Enables or disables the command for Embedded SATA drives during POST.
Port A Sets the drive type of the selected device. For Embedded SATA settings in ATA mode, set this field to Auto to enable BIOS support. Set it to OFF to turn off BIOS support. For AHCI mode or RAID mode, BIOS always enables support.
Model: Displays the drive model of the selected device.
Drive Type: Displays the type of drive attached to the SATA port.
Capacity: Displays the total capacity of the hard drive. The field is undefined for removable media devices such as optical drives.
Port B Sets the drive type of the selected device. For Embedded SATA settings in ATA mode, set this field to Auto to enable BIOS support. Set it to OFF to turn off BIOS support.

For AHCI mode or RAID mode, BIOS always enables support.
Model: Displays the drive model of the selected device.
Drive Type: Displays the type of drive attached to the SATA port.
Capacity: Displays the total capacity of the hard drive. The field is undefined for removable media devices such as optical drives.
Port C Sets the drive type of the selected device. For Embedded SATA settings in ATA mode, set this field to Auto to enable BIOS support. Set it to OFF to turn off BIOS support. For AHCI mode or RAID mode, BIOS always enables support.
Model: Displays the drive model of the selected device.
Drive Type: Displays the type of drive attached to the SATA port.
Capacity: Displays the total capacity of the hard drive. The field is undefined for removable media devices such as optical drives.
Port D Sets the drive type of the selected device. For Embedded SATA settings in ATA mode, set this field to Auto to enable BIOS support. Set it to OFF to turn off BIOS support. For AHCI mode or RAID mode, BIOS always enables support.
Model: Displays the drive model of the selected device.
Drive Type: Displays the type of drive attached to the SATA port.
Capacity: Displays the total capacity of the hard drive. The field is undefined for removable media devices such as optical drives.
Port E Sets the drive type of the selected device. For Embedded SATA settings in ATA mode, set this field to Auto to enable BIOS support. Set it to OFF to turn off BIOS support. For AHCI mode or RAID mode, BIOS always enables support.
Model: Displays the drive model of the selected device.
Drive Type: Displays the type of drive attached to the SATA port.
Capacity: Displays the total capacity of the hard drive. The field is undefined for removable media devices such as optical drives.
Port F Sets the drive type of the selected device. For Embedded SATA settings in ATA mode, set this field to Auto to enable BIOS support. Set it to OFF to turn off BIOS support. For AHCI mode or RAID mode, BIOS always enables support.
Model: Displays the drive model of the selected device.
Drive Type: Displays the type of drive attached to the SATA port.
Menu Item Description

Capacity: Displays the total capacity of the hard drive. The field is undefined for removable media devices such as optical drives.
Port G Sets the drive type of the selected device. For Embedded SATA settings in ATA mode, set this field to Auto to enable BIOS support. Set it to OFF to turn off BIOS support. For AHCI mode or RAID mode, BIOS always enables support.
Model: Displays the drive model of the selected device.
Drive Type: Displays the type of drive attached to the SATA port.
Capacity: Displays the total capacity of the hard drive. The field is undefined for removable media devices such as optical drives.
Port H Sets the drive type of the selected device. For Embedded SATA settings in ATA mode, set this field to Auto to enable BIOS support. Set it to OFF to turn off BIOS support. For AHCI mode or RAID mode, BIOS always enables support.
Model: Displays the drive model of the selected device.
Drive Type: Displays the type of drive attached to the SATA port.
Capacity: Displays the total capacity of the hard drive. The field is undefined for removable media devices such as optical drives.
Port I Sets the drive type of the selected device. For Embedded SATA settings in ATA mode, set this field to Auto to enable BIOS support. Set it to OFF to turn off BIOS support. For AHCI mode or RAID mode, BIOS always enables support.
Model: Displays the drive model of the selected device.
Drive Type: Displays the type of drive attached to the SATA port.
Capacity: Displays the total capacity of the hard drive. The field is undefined for removable media devices such as optical drives.
Port J Sets the drive type of the selected device. For Embedded SATA settings in ATA mode, set this field to Auto to enable BIOS support. Set it to OFF to turn off BIOS support. For AHCI mode or RAID mode, BIOS always enables support.
Model: Displays the drive model of the selected device.
Drive Type: Displays the type of drive attached to the SATA port.
Capacity: Displays the total capacity of the hard drive. The field is undefined for removable media devices such as optical drives.
Menu Item Description

You can use the Boot Settings screen to set the Boot mode to either BIOS or UEFI. It also allows you to specify the boot order.
The Boot Settings screen displays.
The Boot Settings screen details are explained as follows:
Table 16. Boot settings
Boot Mode Enables you to set the boot mode of the system.
If the operating system supports UEFI, you can set this option to UEFI. Setting this field to BIOS allows compatibility with non-UEFI operating systems. By default, the Boot Mode option is set to BIOS.
Boot Sequence Retry Enables or disables the Boot Sequence Retry feature. If this field is enabled and the system fails to boot, the system reattempts the boot sequence after 30 seconds. By default, the Boot Sequence Retry option is set to Enabled.
Hard-Disk Failover Specifies which devices in the Hard-Disk Drive Sequence are attempted in the boot sequence. When the option is Disabled, only the first hard disk device in the list is attempted to boot. When set to Enabled, all hard disk devices are attempted in order, as listed in the Hard-Disk Drive Sequence. This option is not enabled for UEFI Boot Mode.
Boot Option Settings Configures the boot sequence and the boot devices.
You can use the Network Settings screen to modify Preboot eXecution Environment (PXE) device settings. Network Settings are only available in UEFI boot mode. BIOS does not control network settings in the BIOS boot mode. For BIOS boot mode, the network settings are handled by the network controllers option ROM.
Boot Settings · Menu Item Description

The Network Settings screen displays.
The Network Settings screen details are explained as follows:
Table 17. Network settings
PXE Device n (n = 1 to 4) Enables or disables the device. When enabled, a UEFI boot option is created for the device.
PXE Device n Settings (n = 1 to 4)
Allows you to control the configuration of the PXE device.
You can use the Integrated Devices screen to view and configure the settings of all integrated devices including the video controller, integrated RAID controller, and the USB ports.
The Integrated Devices screen displays.
Integrated devices screen details
The Integrated Devices screen details are explained below.
Table 18. Integrated devices
USB 3.0 Setting Enables or disables the USB 3.0 support. Enable this option only if your operating system supports USB 3.0. If you disable this option, devices operate at USB 2.0 speed. USB 3.0 is disabled by default.
User Accessible USB Ports
Enables or disables the USB ports. Selecting Only Back Ports On disables the front USB ports, selecting All Ports Off disables all USB ports. The USB keyboard and mouse operates during boot process in certain operating systems. After the boot process is complete, the USB keyboard and mouse do not work if the ports are disabled.
Internal USB Port Enables or disables the internal USB port. By default, the option is set to Enabled.
Enables or disables the integrated RAID controller. By default, the option is set to Enabled.
Integrated Network Card 1
Enables or disables the integrated network card.
Embedded NIC1 and NIC2
Enables or disables the Embedded NIC1 and NIC2 . If set to Disabled, the NIC may still be available for shared network access by the embedded

management controller. The embedded NIC1 and NIC2 option is only available on systems that do not have NDCs. This option is mutually exclusive with the Integrated Network Card 1 option. Configure this function using the NIC management utilities of the system.
I/OAT DMA Engine Enables or disables the I/OAT option. Enable only if the hardware and software support the feature.
Enables or disables the Embedded Video Controller. By default, the embedded video controller is Enabled. Current state of Embedded Video Controller is Enabled. Current State of Embedded Video Controller is a read only field, indicating the current state for the Embedded Video Controller. If the Embedded Video Controller is the only display capability in the system (that is, no add-in graphics card is installed), then the Embedded Video Controller is automatically used as the primary display even if the Embedded Video Controller setting is Disabled.
Current State of Embedded Video Controller
Displays the current state of the Embedded Video Controller. Current State of Embedded Video Controller is a read only field, indicating the current state for the Embedded Video Controller.
SR-IOV Global Enable Enables or disables the BIOS configuration of Single Root I/O Virtualization (SR-IOV) devices. By default, the SR-IOV Global Enable option is set to Disabled.
OS Watchdog Timer If your system stops responding, this OS Watchdog Timer aids in the recovery of your operating system. When this field is set to Enabled, the operating system is allowed to initialize the timer. When the option is set to Disabled (the default), the timer has no effect on the system.
Memory Mapped I/O above 4GB
Enables or disables the support for PCIe devices that require large amounts of memory. By default, the option is set to Enabled.
Slot Disablement Enables or disables the available PCIe slots on your system. The Slot Disablement feature controls the configuration of PCIe cards installed in the specified slot. Slot disablement must be used only when the installed peripheral card is preventing booting into the operating system or causing delays in system startup. If the slot is disabled, both the Option ROM and UEFI driver are disabled.
You can use the Serial Communication screen to view the properties of the serial communication port.
The Serial Communication screen is displayed
Serial Communication screen settings
The Serial Communication screen details are explained below.
Menu Item Description · Embedded Video Controller

Table 19. Serial communication
Serial Communication Selects serial communication devices (Serial Device 1 and Serial Device 2) in the BIOS. This is where you can select BIOS console redirection and specify the port address. By default, Serial Communication option is set to Auto.
Serial Port Address With Serial Communication, you can set the port address for serial devices. By default, the Serial Port Address option is set to Serial Device 1=COM2, Serial Device 2=COM1
External Serial Connector With the External Serial Connector, you can associate the External Serial Connector to Serial Device 1, Serial Device 2, or the Remote Access Device using this field.
Failsafe Baud Rate Displays the Failsafe baud rate for console redirection. The BIOS attempts to determine the baud rate automatically. This Failsafe baud rate is used only if the attempt fails, and the value must not be changed. By default, the Failsafe Baud Rate option is set to 115200.
Remote Terminal Type Sets the remote console terminal type. By default, the Remote Terminal Type option is set to VT 100/VT 220.
Redirection After Boot Enables or disables the BIOS console redirection when the operating system is loaded. By default, the Redirection After Boot option is set to Enabled.
You can use the System Profile Settings screen to enable system performance settings such as power management.
The System Profile Settings screen is displayed.
Menu Item Description

System profile screen settings
The System Profile Settings screen details are explained as follows:
Table 20. System profile settings
System Profile Sets the system profile. If you set the System Profile option to a mode other than Custom, the BIOS automatically sets the rest of the options. You can only change the rest of the options if the mode is set to Custom. By default, the System Profile option is set to Performance Per Watt Optimized (DAPC). DAPC is Dell Active Power Controller.
Controls the number of turbo boost enabled cores for processor 1. By default, the maximum number of cores is enabled. • Monitor/Mwait: Enables the Monitor/Mwait instructions in the processor. By default, the Monitor/Mwait option is set to Enabled for all system profiles, except Custom.
Menu Item Description

You can use the System Security screen to edit some settings such as setting the system password, setup password and disabling the power button.
The System Security screen is displayed.
System security screen settings
The System Security Settings screen details are explained as follows:
Table 21. System security settings
Intel AES-NI Improves the speed of applications by performing encryption and decryption using the Advanced Encryption Standard Instruction Set and is set to Enabled by default.
System Password Sets the system password. This option is set to Enabled by default and is read-only if the password jumper is not installed in the system.
Setup Password Sets the setup password. This option is read-only if the password jumper is not installed in the system.
Password Status Locks the system password. By default, the Password Status option is set to Unlocked.
Allows you to control the reporting mode of the Trusted Platform Module (TPM). By default, the TPM Security option is set to Off. You can only modify the TPM Status, TPM Activation , and Intel TXT fields if the TPM Status field is set to either On with Pre-boot Measurements or On without Pre-boot Measurements.
TPM Information Changes the operational state of the TPM. By default, the TPM Activation option is set to No Change.
TPM Status Displays the TPM status.
Clears all the contents of the TPM. By default, the TPM Clear option is set to No.

Intel TXT Enables or disables the Intel Trusted Execution Technology (TXT). To enable Intel TXT, Virtualization Technology must be enabled and TPM Security must be Enabled with Pre-boot measurements. By default, the Intel TXT option is set to Off
Power Button Enables or disables the Power button on the front of the system. By default, the Power Button option is set to Enabled.
NMI Button Enables or disables the NMI button on the front of the system. By default, the NMI Button option is set to Disabled.
AC Power Recovery Sets how the system reacts after AC power is restored to the system. By default, the AC Power Recovery option is set to Last.
AC Power Recovery Delay Sets how the system supports staggering of power up after AC power is restored to the system. By default, the AC Power Recovery Delay option is set to Immediate.
User Defined Delay (60s to 240s) Sets the User Defined Delay when the User Defined option for AC Power Recovery Delay is selected.
UEFI Variable Access Provides varying degrees of securing UEFI variables. When set to Standard (the default) UEFI variables are accessible in the Operating System per the UEFI specification. When set to Controlled, selected UEFI variables are protected in the environment and new UEFI boot entries are forced to be at the end of the current boot order.
Secure Boot Enables Secure Boot, where the BIOS authenticates each pre-boot image using the certificates in the Secure Boot Policy. Secure Boot is disabled by default.
Secure Boot Policy When Secure Boot policy is Standard, the BIOS uses the system manufacturer’s key and certificates to authenticate pre-boot images. When Secure Boot policy is Custom, the BIOS uses the user-defined key and certificates. Secure Boot policy is Standard by default.
Secure Boot Policy Summary
Displays the list of certificates and hashes that secure boot uses to authenticate images.
Secure Boot Custom Policy Settings screen
Secure Boot Custom Policy Settings is displayed only when Secure Boot Policy is set to Custom. In the System Setup Main Menu, click System BIOS → System Security → Secure Boot Custom Policy Settings.
The Secure Boot Custom Policy Settings screen details are explained as follows:
Table 22. Secure boot custom policy settings
Platform Key Imports, exports, deletes, or restores the platform key (PK).
Key Exchange Key Database Allows you to import, export, delete, or restore entries in the Key Exchange Key (KEK) Database.
Authorized Signature Database Imports, exports, deletes, or restores entries in the Authorized Signature Database (db).
Menu Item Description · Menu Item Description

Forbidden Signature Database Imports, exports, deletes, or restores entries in the Forbidden Signature Database (dbx).
You can use the Miscellaneous Settings screen to perform some configurations such as updating the asset tag, and changing the system date and time.
The Miscellaneous Settings screen displays.
The Miscellaneous Settings screen details are explained as follows:
Table 23. Miscellaneous settings
System Time System Time lets you set the time on the system.
System Date System Date lets you set the date on the system.
Asset Tag Displays the asset tag and lets you to modify it for security and tracking purposes.
Keyboard NumLock Keyboard NumLock lets you set whether the system boots with the NumLock enabled or disabled. By default the Keyboard NumLock is set to On.
F1/F2 Prompt on Error Enables or disables the F1/F2 prompt on error. By default, F1/F2 Prompt on Error is set to Enabled. The F1/F2 prompt also includes keyboard errors.
Load Legacy Video Option ROM You can determine whether the system BIOS loads the legacy video (INT 10H) option ROM from the video controller. Selecting Enabled in the operating system does not support UEFI video output standards. This field is only for UEFI boot mode. You cannot set this to Enabled if UEFI Secure Boot mode is enabled.
In-System Characterization This option enables or disables In-System Characterization. By default, In-System Characterization is set to Disabled. The two other options are Enabled and Enabled - No Reboot.
Menu Item Description · Miscellaneous settings screen · Menu Item Description

When enabled, In-System Characterization (ISC) runs during POST upon detecting relevant change(s) in system configuration to optimize system power and performance. ISC takes about 20 seconds to run, and system reset is required for ISC results to be applied. The Enabled - No Reboot option runs ISC and continues without applying ISC results until the next time system reset occurs. The Enabled option runs ISC and forces an immediate system reset so that ISC results can be applied. It takes the system longer to be ready due to the forced system reset. When disabled, ISC does not run.
With Boot Manager you can add, delete, and arrange boot options. You can also access System Setup and boot options without restarting the system.
The Boot Manager screen allows you to select boot options and diagnostic utilities.
If your operating system begins to load before you press F11, allow the system to finish booting, and then restart your system and try again.
Table 24. Boot manager main menu
Continue Normal Boot The system attempts to boot to devices starting with the first item in the boot order. If the boot attempt fails, the system continues with the next item in the boot order until the boot is successful or no more boot options are found.
One Shot Boot Menu Takes you to the boot menu where you can select a one time boot device to boot from.
Launch System Setup Allows you to access the System Setup.
Launch Lifecycle Controller Exits the Boot Manager and invokes the Lifecycle Controller program.
System Utilities Launches system utilities menu such as system diagnostics and UEFI shell.
Menu Item Description · Menu Item Description

You may have to change the boot order if you want to boot from a USB key or an optical drive. The instructions given below may vary if you have selected BIOS for Boot Mode.
With System Setup, you can to specify the boot mode for installing your operating system:
You must select the boot mode in the Boot Mode field of the Boot Settings screen of System Setup. Once you specify the boot mode, the system boots in the specified boot mode and you then proceed to install your operating system from that mode. Thereafter, you must boot the system in the same boot mode (BIOS or UEFI) to access the installed operating system. Trying to boot the operating system from the other boot mode causes the system to halt at startup.
You can assign a new System Password and Setup Password or change an existing System Password and Setup Password only when the password jumper setting is enabled and Password Status is Unlocked.
If the password jumper setting is disabled, the existing System Password and Setup Password are deleted and you need not provide the system password to boot the system.
About this task To assign a System Password and Setup Password, follow the steps below:
Steps 1. To enter System Setup, press F2 immediately after a power-on or reboot.

Use the following guidelines to assign the system password:
A message prompts you to re-enter the system password.
A message prompts you to re-enter the setup password.
A message prompts you to save the changes.
Prerequisites Ensure that the Password jumper is set to enabled and the Password Status is Unlocked before attempting to delete or change the existing System and/or Setup password. You cannot delete or change an existing System or Setup password if the Password Status is Locked.
Steps 1. To enter System Setup, press F2 immediately after a power on or restart.
The System BIOS screen is displayed.
The System Security screen is displayed.
If you change the System and Setup password a message prompts you to re-enter the new password. If you delete the System and Setup password, a message prompts you to confirm the deletion.

Safety instructions
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
For more information, see Removing the front bezel.
For more information, see Removing the system cover.
For more information, see Installing the system cover.

For more information, see Installing the front bezel.
You need the following tools to perform the removal and installation procedures:
The following tools are required for assembling cables for a DC power supply unit (PSU):


Figure 10. Removing and installing the front bezel

http://www.Dell.com/XCSeries/XC730xd/Bezel
Related video · Steps

The system cover slides back and the tabs on the system cover disengages from the slots on the chassis.

Figure 11. Removing and installing the system cover

http://www.Dell.com/XCSeries/XC730xd/Cover
Prerequisites Ensure that you read the Safety instructions.
Related videos

Steps 1. Align the slots of the system cover with the tabs on the chassis.
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.


Figure 12. Inside the system—Dell XC730xd

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Hold the shroud and lift it away from the system.

Figure 13. Removing and installing the cooling shroud
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Steps · Next steps

Steps 1. Align the tabs on the cooling shroud with the securing slots on the chassis.
Your system supports six hot-swappable cooling fans.
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Press the fan release tab and lift the cooling fan out of the cooling-fan assembly.
Next steps · Steps


Figure 14. Removing and installing a cooling fan

http://www.Dell.com/XCSeries/XC730xd/Fans
Next steps · Related videos

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Steps 1. Align the plug at the base of the cooling fan with the connector on the system board.
Follow the procedure listed in After working inside your system.
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Steps 1. Unlock the cooling-fan assembly from the chassis by lifting the release levers upward.
Next steps


Figure 15. Removing and installing the cooling-fan assembly
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Next steps

Steps 1. Align the cooling-fan assembly slots with the guide pins on the chassis.
Follow the procedure listed in After working inside your system.
Your system supports DDR4 registered DIMMs (RDIMMs), and load reduced DIMMs (LRDIMMs).
Memory bus operating frequency can be 1333 MT/s, 1600 MT/s, 1866 MT/s, or 2133 MT/s depending on the following factors:
The system contains 24 memory sockets split into two sets of 12 sockets, one set per processor. Each 12- socket set is organized into four channels. In each channel, the release levers of the first socket are marked white, the second socket black, and the third socket green.
Next steps


Figure 16. Memory socket locations


Figure 17. Memory socket locations
Memory channels are organized as follows:

The following table shows the memory populations and operating frequencies for the supported configurations.
Table 25. The memory populations and operating frequencies for the supported configurations.
DIMM Type DIMMs Populated/ Channel
RDIMM 1 2133, 1866, 1600, 1333 Dual rank or single rank
2 2133, 1866, 1600, 1333 Dual rank or single rank
3 1866, 1600, 1333 Dual rank or single rank
LRDIMM 1 2133, 1866, 1600, 1333 Quad rank
2 2133, 1866, 1600, 1333 Quad rank
3 1866, 1600, 1333 Quad rank
This system supports Flexible Memory Configuration, you can configure and run the system in any valid chipset architectural configuration. The following are the recommended guidelines for installing memory modules:
The following tables show sample memory configurations for one and two processor configurations that follow the appropriate memory guidelines.
Operating Frequency (in · Maximum DIMM Rank/Channel · MT/s)

Table 26. Memory configurations—two processors
System capacity (in GB)
DIMM size (in GB)
DIMM rank, organization, and frequency
64 16 4 2R, x4, 2133 MT/s,
2R, x4, 1866 MT/s,
128 16 8 2R, x4, 2133 MT/s,
2R, x4, 1866 MT/s,
256 16 16 2R, x4, 2133 MT/s,
A1, A2, A3, A4, A5, A6, A7, A8, B1, B2, B3, B4, B5, B6, B7, B8
2R, x4, 1866 MT/s,
384 16 24 2R, x4, 2133 MT/s,
A1, A2, A3, A4, A5, A6, A7, A8, A9, A10, A11, A12, B1, B2, B3, B4, B5, B6, B7, B8, B9, B10, B11, B12
2R, x4, 1866 MT/s,
512 32 16 LRDIMM, 4R, x4, 2133 MT/s
A1, A2, A3, A4, A5, A6, A7, A8, B1, B2, B3, B4, B5, B6, B7, B8
768 32 24 LRDIMM, 4R, x4, 1866 MT/s
A1, A2, A3, A4, A5, A6, A7, A8, A9, A10, A11, A12, B1, B2, B3, B4, B5, B6, B7, B8, B9, B10, B11, B12
LRDIMM, 4R, x4, 1600 MT/s
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Number of DIMMs · DIMM slot population

Steps 1. Locate the appropriate memory module socket.

Figure 18. Removing and installing a memory module

http://www.Dell.com/XCSeries/XC730xd/DIMMS
Related videos

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Steps 1. Locate the appropriate memory-module socket.


Figure 19. Installing the memory module
When the memory module is properly seated in the socket, the levers on the memory module socket align with the levers on the other sockets that have memory modules installed.
The system should have already changed the value to reflect the installed memory.
A SATADOM is a disk-on-module (DOM) form factor with an incorporated standard SATA data connection. By default, the SATADOM comes with a power cable installed and is set in a Read/Write position.
The SATADOM uses an onboard SATA controller and does not require an additional controller.
With Nutanix, you can locate the boot device on a separate controller from the data drives, which improves system disk performance.
Next steps

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Steps 1. Unplug the power cable from the SATADOM Tape Backup Unit (TBU) power connector.


Figure 20. Removing and installing SATADOM
Next steps Follow the procedure listed in After working inside your system.
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

Steps 1. Press the lock release on the SATADOM and plug the SATADOM into the preferred SATADOM connector on the system board.
Next steps Follow the procedure listed in After working inside your system.
Use the following procedure when:
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Steps 1. To remove the heat sink:

a. Loosen one of the screws that secure the heat sink to the system board.
Wait 30 seconds for the heat sink to loosen from the processor. b. Remove the screw diagonally opposite the screw you first removed. c. Repeat the procedure for the remaining two screws. d. Remove the heat sink.

Figure 21. Removing and installing a processor


Figure 22. Removing and installing a processor heat sink

Figure 23. Removing and installing a processor heat sink


Figure 24. Processor shield
a. Release the open first socket-lever near the unlock icon
by pushing the lever down and out from under the tab.
b. Similarly, release the close first socket-release lever near the lock icon
by pushing the lever down and out from under the tab. Lift the lever 90 degrees upward. c. Lower the open first socket-release lever to lift the processor shield.


Figure 25. Removing and installing a processor
d. Hold the tab on the processor shield and lift the processor shield until the open first socket-
release lever lifts up.
Next steps

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Steps 1. Remove the heat sink.
If the processor has previously been used in a system, remove any remaining thermal grease from the processor using a lint-free cloth.
by pushing the lever down and out from under the tab.
by pushing the lever down and out from under the tab. Lift the lever 90 degrees upward.

a. Align the processor with the socket keys.
e. Lower the close first socket-release lever near the lock icon
and push it under the tab to lock it..
f. Similarly, lower the open first socket-release lever near the unlock icon
and push it under the tab to lock it.
a. If applicable, remove the existing thermal grease from the heat sink using a clean lint-free cloth. b. Apply thermal grease on the top of the processor. Use the thermal-grease syringe included with
your processor kit to apply the grease in a thin spiral on the top of the processor as shown in the figure.

Figure 26. Applying thermal grease on the top of the processor

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Steps 1. Press the release tab and slide the card holder toward the back of the chassis to release the PCIe card holder from the chassis.
Next steps


Figure 27. Removing and installing the PCIe card holder
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Steps 1. Align the PCIe card holder with the notches and tabs on the power supply unit cage.
Next steps · Next steps

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Steps 1. To open the PCIe card holder latch, press the release tab.

Figure 28. Opening and closing the PCIe card holder latch
Follow the procedure listed in After working inside your system.
Next steps

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Steps 1. Pull the tab to release it from the notch and slide the cable retention bracket toward the front of the chassis to release it from the chassis.

Figure 29. Removing and installing the cable retention bracket


http://www.Dell.com/XCSeries/XC730xd/cabling
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Your system includes a dedicated expansion-card slot on the system board for an integrated controller card. The integrated storage controller card provides the integrated storage subsystem for your system’s internal hard drives. The controller supports SAS and SATA hard drives as supported by the version of the storage controller included with your system.

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Steps 1. Loosen the screws that secure the integrated storage controller cable to the integrated storage- controller card connector on the system board.

Figure 30. Removing and installing the integrated storage controller card

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Ensure that the tabs on the system board align with the screw holes on the integrated storage- controller card.

Figure 31.
http://www.Dell.com/XCSeries/XC730xd/SC

Depending on your system configuration:
The following PCI Express generation 3 expansion cards are supported:
Table 27. Supported expansion cards
Riser PCIe slot Processor connection
Height Length Link width Slot width
1 1 Processor 2 Low Profile Half Length x8 x16
1 2 Processor 2 Low Profile Half Length x8 x16
1 3 Processor 2 Low Profile Half Length x8 x16
2 4 Processor 2 Full Height Full Length x16 x16
2 5 Processor 1 Full Height Full Length x8 x16
3 (default) 6 Processor 1 Full Height Full Length x8 x16
3 (alternate) 6 Processor 1 Full Height Full Length x16 x16
3 (default) 7 Processor 1 Full Height Full Length x8 x16
The following table provides guidelines for installing expansion cards to ensure proper cooling and mechanical fit. The expansion cards with the highest priority should be installed first using the slot priority indicated. Install all other expansion cards in card priority and slot priority order.
Table 28. Expansion card installation order
Card priority Card type Slot priority Max allowed
1 PCIe Bridge 4 1
2 10 Gb NICs (full height) 4,6,5 3
10 Gb NICs (low profile) 2,3,1 3
3 1 Gb NICs (full height) 4,6,5 3
1 Gb NICs (low profile) 2,3,1 1
4 Integrated RAID integrated slot 1
5 NDC integrated slot 3

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Steps 1. Disconnect any cables connected to the expansion card.


Figure 32. Removing and installing an expansion card from expansion-card riser 2 or 3
Follow the procedure listed in After working inside your system.

http://www.Dell.com/XCSeries/XC730xd/PCI
Next steps · Related video

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Steps 1. Unpack the expansion card and prepare it for installation.
For instructions, see the documentation accompanying the card.
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Steps 1. Press tab A and rotate the latch clockwise.
Next steps


Figure 33. Removing and installing an expansion-card from expansion-card riser 1
Next steps

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Steps 1. Unpack the expansion card and prepare it for installation.
For instructions, see the documentation accompanying the card.
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Holding the slots on the expansion-card riser, lift the riser from the riser connector on the system board.
Next steps · Steps


Figure 34. Removing and installing the expansion card riser 1


Figure 35. Identifying connectors on the expansion card riser 1


Figure 36. Removing and installing the expansion card riser 2


Figure 37. Identifying connectors on the expansion card riser 2


Figure 38. Removing and installing the expansion card riser 3


Figure 39. Identifying connectors on the expansion card riser 3 (default)

Figure 40. Identifying connectors on the expansion card riser 3 (alternate)
Next steps

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Steps 1. Align the expansion-card riser with the connectors and the riser guides on the system board.
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Locate the SD card slot on the internal dual SD module and press the card to release it from the slot.
Steps 1. Remove the PCIe Card.
Follow the procedure listed in After working inside your system.
Next steps · Next steps · Related videos


http://www.Dell.com/XCSeries/XC730xd/IDSDM
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Steps 1. Locate the SD card connector on the internal dual SD module. Orient the SD card appropriately and insert the contact-pin end of the card into the slot.
Follow the procedure listed in After working inside your system.
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Steps 1. Locate the internal dual SD module on the system board.
Next steps


Figure 41. Removing and installing the Internal Dual SD Module (IDSDM)
Table 29. The following table describes the IDSDM indicator codes.
Convention IDSDM indicator code Description
A Green Indicates that the card is online
B Flashing green Indicates rebuild or activity
C Flashing amber Indicates card mismatch or that the card has failed
D Amber Indicates that the card is offline, has failed, or is write protected

Convention IDSDM indicator code Description
E Not lit Indicates that the card is missing or is
Follow the procedure listed in After working inside your system
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Steps 1. Locate the IDSDM connector on the system board. To locate the IDSDM connector, see System board connectors
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Next steps · Next steps

Steps 1. Using a #1 Phillips screwdriver, loosen the captive screws that secure the network daughter card to the system board.

Figure 42. Removing and installing the Network Daughter Card (NDC)
Next steps · Related videos


http://www.Dell.com/XCSeries/XC730xd/NDC
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Steps 1. Angle the card so that the Ethernet connectors fit through the slot in the back panel.
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Next steps

Steps 1. Locate the battery socket. For more information, see System board connectors.

Figure 43. Removing the system battery


Figure 44. Installing the system battery

http://www.Dell.com/XCSeries/XC730xd/Battery
Your system supports one of the following:
Next steps · Related videos

NOTE: When two identical PSUs are installed, power supply redundancy (1+1 – withredundancy or 2+0 – without redundancy) is configured in system BIOS. In redundant mode, power is supplied to the system equally from both PSUs when Hot Spare is disabled. When Hot Spare is enabled, one of the PSUs are put into standby when system usage is low to maximize efficiency.
Your system supports the Hot Spare feature that significantly reduces the power overhead associated with power supply redundancy.
When the Hot Spare feature is enabled, one of the redundant power supplies is switched to a sleep state. The active power supply supports 100 percent of the load, thus operating at higher efficiency. The power supply in the sleep state monitors output voltage of the active power supply. If the output voltage of the active power supply drops, the power supply in the sleep state returns to an active output state.
If having both power supplies active is more efficient than having one power supply in a sleep state, the active power supply can also activate a sleeping power supply.
The default power supply settings are as follows:
You can configure the Hot Spare feature using the iDRAC settings. For more information on iDRAC settings, see the Integrated Dell Remote Access Controller User’s Guide at dell.com/support/home
If you are installing a second power supply unit, remove the power supply unit blank in the bay by pulling the blank outward.


Figure 45. Removing and installing the power supply blank
Install the power supply unit blank only in the second power supply unit bay.
To install the power supply unit blank, align the blank with the power supply unit bay and push it into the chassis until it clicks into place.
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Steps 1. Disconnect the power cable from the power source and from the power supply unit you intend to remove and remove the cables from the strap.


Figure 46. Removing and installing an AC power supply unit
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Steps 1. Verify that both the power supply units are the same type and have the same maximum output power.

NOTE: When installing, hot-swapping, or hot-adding a new power supply unit, wait for 15 seconds for the system to recognize the power supply unit and determine its status. The power supply redundancy may not occur until discovery is complete. Wait until the new power supply unit is discovered and enabled before you remove the other power supply unit. The power- supply unit status indicator turns green to signify that the power supply unit is functioning properly.

http://www.Dell.com/XCSeries/XC730xd/PSU
Your system supports up to two –(48–60) V DC power supplies (when available).
WARNING: For equipment using –(48–60) V DC power supplies, a qualified electrician must perform all connections to DC power and to safety grounds. Do not attempt connecting to DC power or installing grounds yourself. All electrical wiring must comply with applicable local or national codes and practices. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow all safety instructions that came with the product.
Wire-stripper pliers capable of removing insulation from size 10 AWG solid or stranded, insulated copper wire

WARNING: For equipment using –(48–60) V DC power supplies, a qualified electrician must perform all connections to DC power and to safety grounds. Do not attempt connecting to DC power or installing grounds yourself. All electrical wiring must comply with applicable local or national codes and practices. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow all safety instructions that came with the product.
Steps 1. Disconnect the power wires from the power source and the connector from the power supply you intend to remove.

Figure 47. Removing and installing a DC power supply
Required wires

WARNING: For equipment using –(48–60) V DC power supplies, a qualified electrician must perform all connections to DC power and to safety grounds. Do not attempt connecting to DC power or installing grounds yourself. All electrical wiring must comply with applicable local or national codes and practices. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow all safety instructions that came with the product.
Steps 1. Verify that both the power supplies are of the same type and have the same maximum output power.
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
CAUTION: If you are using the Trusted Platform Module (TPM) with an encryption key, you may be prompted to create a recovery key during program or System Setup. Be sure to create and safely store this recovery key. If you replace this system board, you must supply the recovery key when you restart your system or program before you can access the encrypted data on your hard drives.

a. cooling shroud
b. cooling-fan assembly
c. hard-drive tray (if installed)
d. power supply unit(s)
e. all expansion-card risers
f. integrated storage controller card
g. internal dual SD module
h. internal USB key (if installed)
i. PCIe card holder
j. cable retention bracket
k. heat sink(s)/heat-sink blank(s)
l. processors(s)/processor blank(s)
m. memory modules and memory module blanks
n. network daughter card
Steps 1. Disconnect the mini SAS cable from the system board.
Sliding the system board toward the front of the chassis disengages the connectors from the back of the chassis slots.


Figure 48. Removing and installing the system board
Next steps

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Steps 1. Unpack the new system board assembly.
a. Cable retention bracket
b. PCIe card holder
c. Hard-drive tray (if applicable)
d. Integrated storage controller card
e. Internal USB key (if applicable)
f. Internal dual SD module
g. All expansion-card risers
h. Heat sink(s)/heat-sink blank(s) and processors(s)/processor blank(s)
i. Memory modules and memory module blanks
j. Network daughter card
k. Cooling-fan assembly
l. Cooling shroud
m. Power supply unit(s)
a. Use the Easy Restore feature to restore the Service Tag. For more information, see Restoring the Service Tag using Easy Restore.
Next steps

b. If the Service Tag is not backed up in the backup flash device, enter the system Service Tag manually. For more information, see Entering the system Service Tag using System Setup.
c. Update the BIOS and iDRAC versions.
d. Re-enable the Trusted Platform Module (TPM). For more information, see Re-enabling the TPM for TXT users.

http://www.Dell.com/XCSeries/XC730xd/MOBO
Entering the system Service Tag using System Setup
If you know the system Service Tag, use the System Setup menu to enter the Service Tag.
For more information, see Integrated Dell Remote Access Controller User's Guide, at dell.com/ esmmanuals.
Restoring the Service Tag using Easy Restore
Use the Easy Restore feature if you do not know the Service Tag of your system. The Easy Restore feature allows you to restore your system’s Service Tag, license, UEFI configuration, and the system configuration data after replacing the system board. All data is backed up in a backup flash device automatically. If BIOS detects a new system board and the Service Tag in the backup flash device, BIOS prompts the user to restore the backup information.
If BIOS detects a new system board, and if the Service Tag is present in the backup flash device, BIOS displays the Service Tag, the status of the license, and the UEFI Diagnostics version.
After the restore process is complete, BIOS prompts to restore the system configuration data.
Related videos

After the restore process is complete, the system restarts.
The Trusted Platform Module (TPM) is used to generate/store keys, protect/authenticate passwords, and create/store digital certificates. TPM can also be used to enable the BitLocker hard drive encryption feature in Windows Server.
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Ensure that you read the Safety instructions.
Steps 1. Locate the TPM connector on the system board.


Figure 49. Installing the TPM
Initialize the TPM.
For more information on initializing the TPM, see http://technet.microsoft.com/en-us/library/ cc753140.aspx.
The TPM Status changes to Enabled, Activated.

Your system supports Enterprise-class hard drives, which are designed for 24x7 operating environment. Selecting the correct drive class optimizes quality, functionality, performance, and reliability of the hard drives.
The Nutanix Web GUI provides a feature to help locate a specific HDD. When the front LEDs are turned on using the Nutanix Web GUI, the HDD or SSD you are trying to locate continues to blink as long as there is I/O activity. The other HDDs or SSDs blink twice every second (in addition to blinking because of I/O activity). The HDD or SSD you are trying to locate does not blink twice every second.
Due to industry advances, in some cases, the larger capacity drives have been changed to a larger sector size. The larger sector size can have impacts on operating systems and applications. For more information about these hard drives, see the 512e and 4Kn Disk Formats whitepaper and 4K Sector HDD FAQ document at dell.com/xcseriesmanuals
All hard drives are connected to the system board through the hard-drive backplane. Hard drives are supplied in hot-swappable hard-drive carriers that fit in the hard-drive slots.
Use only hard drives that have been tested and approved for use with the hard-drive backplane.
When you format a hard drive, allow enough time for the formatting to be completed. Be aware that high-capacity hard drives can take a number of hours to format.
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Press the release button and slide the hard-drive blank out of the hard-drive slot.
Steps


Figure 50. Removing and installing a 2.5 inch hard-drive blank

http://www.Dell.com/XCSeries/XC730xd/MidHDDs
Insert the hard-drive blank into the hard-drive slot until the release button clicks into place.
Next steps If applicable, install the front bezel.
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Related video · Steps

Ensure that you read the Safety instructions.
Pull the hard-drive blank out until it is free of the hard-drive slot.

Figure 51. Removing and installing a 2.5 inch hard-drive blank (back)
Insert the hard-drive blank into the hard-drive slot until it clicks into place.
Next steps Follow the procedure listed in After working inside your system.
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Steps · Steps

Press the release button and slide the blank out of the hard-drive slot.

Figure 52. Removing and installing a 3.5 inch hard-drive blank
Next steps If applicable, install the front bezel.
Insert the hard-drive blank into the hard-drive slot until the release button clicks into place.
Next steps If applicable, install the front bezel.
The Nutanix Web GUI provides a feature to help locate a specific HDD. When the front LEDs are turned on using the Nutanix Web GUI, the HDD or SSD you are trying to locate continues to blink as long as there is I/O activity. The other HDDs or SSDs blink twice every second (in addition to blinking because of I/O activity). The HDD or SSD you are trying to locate does not blink twice every second.
Steps · Steps

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
If the hard drive is online, the green activity/fault indicator flashes as the drive is turned off. When the hard-drive indicators are off, the hard drive is ready for removal.
Steps 1. Press the release button to open the hard-drive carrier release handle.

Figure 53. Removing and installing a hot-swap hard drive

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Steps 1. If a HDD blank is installed in the HDD slot, remove it.
Steps 1. Remove the screws from the slide rails on the hard-drive carrier.


Figure 54. Removing and installing a hard drive into a hard-drive carrier
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Steps 1. Insert the hard drive into the hard-drive carrier with the connector end of the hard drive toward the back.
When aligned correctly, the back of the hard drive is flush with the back of the hard-drive carrier.
Depending on your system configuration:
2.5 inch (x24) SAS/SATA backplane
3.5 inch (x12) SAS/SATA backplane

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Steps 1. Disconnect the SAS/SATA data, signal, and power cable(s) from the backplane.


Figure 55. Removing and installing the 2.5 inch (x24) SAS/SATA backplane


Figure 56. Cabling diagram—2.5 Inch (x24) SAS/SATA backplane— (option 2)


Figure 57. Removing and installing the 3.5 inch (x12) SAS/SATA backplane
Next steps

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Steps 1. Use the hooks on the chassis as guides to align the hard-drive backplane.
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Steps 1. Disconnect all the cables from the backplane.
Next steps


Figure 58. Removing and installing the optional 2.5 inch (x2) hard-drive backplane

http://www.Dell.com/XCSeries/XC730xd/MidBP
Related video

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Steps 1. Disconnect the control panel cable from the hard-drive backplane by pulling on the plastic pull tab.


Figure 59. Removing and installing the control panel

http://www.Dell.com/XCSeries/XC730xd/CP
Next steps · Related video

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Steps 1. Replace the blank information tag in the new control panel with the information tag retained from the old control panel.
Follow the procedure listed in After working inside your system.
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Steps 1. Rotate the locking tab on the I/O cable connector clockwise 90 degrees to release the lock.
For more information on the locking tab, see Removing the hard-drive backplane.
Next steps


Figure 60. Removing and installing the I/O panel
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Next steps

Steps 1. Fold the PPID label around the cable.
Follow the procedure listed in After working inside your system.
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Press the release tabs and lift the backplane out of the hard-drive tray.
Next steps · Steps


Figure 61. Removing and installing the 3.5 inch (x4) hard-drive backplane
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Steps 1. Align the hard-drive backplane with the guide pin on the chassis and lower the hard-drive backplane on the chassis until it is firmly seated.
About this task · Related video



Safety first—for you and your system
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
You must boot to the same boot mode in which you installed the operating system.
For all other startup issues, note the system messages that appear on the screen.
Ensure that all external cables are securely attached to the external connectors on your system before troubleshooting any external devices.
If the tests run successfully, the problem is not related to video hardware.
If the tests fail, see Getting Help.
About this task Use the following steps to troubleshoot a USB keyboard/mouse. For other USB devices, go to step 7. Steps 1. Disconnect the keyboard and mouse cables from the system and reconnect them.

Check if USB 3.0 is enabled in System Setup. If enabled, disable it and see if the issue is resolved (older operating systems may not support USB 3.0).
If the problem is not resolved, proceed to the next step to begin troubleshooting other USB devices attached to the system.
If your keyboard is not functioning, you can also use remote access.
If all troubleshooting fails, see Getting Help.
For information on USB storage device and server configuration, see the Integrated Dell Remote Access Controller User's Guide at dell.com/esmanuals
icon.
Next steps If all troubleshooting fails, see Getting help.
Next steps · Steps

For information on USB laptop connection and server configuration, see the Integrated Dell Remote Access Controller User's Guide at dell.com/esmanuals
icon with a USB Type A/A cable.
Next steps If all troubleshooting fails, see Getting help.
Steps 1. Turn off the system and any peripheral devices connected to the serial port.
If the problem is resolved, replace the interface cable with a known good cable.
If the problem persists, see Getting Help.
Steps 1. Run the appropriate diagnostic test. See Using system diagnostics for available diagnostic tests.
Remove and reinstall the drivers if applicable. See the NIC documentation.
Steps · Next steps

If all troubleshooting fails, see Getting Help.
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Steps 1. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
If the system does not start properly, see Getting Help.
If the tests fail, see Getting Help.
Next steps · Next steps

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Steps 1. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
If the tests fail, see Getting Help.
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Next steps

Steps 1. Re-enter the time and date in the System Setup.
If the date and time are not correct in the System Setup, check the SEL for system battery messages.
Next steps If the problem persists, see Getting Help.
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
For example, loose power cables.
For example, loose power cables.
If the LED You may have to upgrade to a higher wattage power supply unit.
If the problem persists, see Getting Help.

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Ensure that the following conditions exist:
Additional cooling can be added by one of the following methods:
From the iDRAC Web GUI:
From F2 System Setup
For more information, see the Integrated Dell Remote Access Controller User's Guide at dell.com/ esmmanuals.
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Steps 1. Remove the system cover.
From RACADM commands

If the problem persists, see Getting Help.
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Steps 1. If the system is operational, run the appropriate diagnostic test. See Using system diagnostics for available diagnostic tests.
If diagnostics indicate a fault, follow the corrective actions provided by the diagnostic program.
If an error message is displayed indicating a fault with a specific memory module, go to step 12.
If the memory settings match the installed memory but the problem still persists, go to step 12.
If the problem is not resolved, proceed with the next step.
If an error message is displayed on the screen, this may indicate a problem with the installed DIMM type(s), incorrect DIMM installation, or defective DIMM(s). Follow the on-screen instructions to resolve the problem.
Next steps

If the problem persists after all memory modules have been checked, see Getting Help.
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Steps 1. Enter the System Setup and ensure that the Internal SD Card Port is enabled.
Verify that correct SD slot is set as Primary SD Card.
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Next steps

Steps 1. Run the appropriate diagnostic test. For more information, see Using system diagnostics.
Depending on the results of the diagnostics test, proceed as needed through the following steps.
Next steps If the problem persists, try troubleshooting the expansion cards or see Getting Help.
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
a. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
b. Remove the system cover.
c. Reinstall one of the expansion cards.
d. Install the system cover.
e. Run the appropriate diagnostic test. For more information, see Using system diagnostics.
If the tests fail, see Getting Help.

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Steps 1. Run the appropriate diagnostic test. For more information, see Using system diagnostics.
If the tests fail, see Getting Help.
a. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet. b. Remove the system cover. c. Reinstall one of the expansion cards. d. Install the system cover. e. Run the appropriate diagnostic test. For more information, see Using system diagnostics.
If the problem persists, see Getting Help.
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Steps 1. Run the appropriate diagnostics test. See Using system diagnostics for available diagnostic tests.
Next steps

If the problem persists, see Getting Help.
For a list of event and error messages generated by the system firmware and agents that monitor system components, see the Dell Event and Error Messages Reference Guide at dell.com/esmmanuals
A warning message alerts you to a possible problem and prompts you to respond before the system continues a task. For example, before you format a hard drive, a message warns you that you may lose all data on the hard drive. Warning messages usually interrupt the task and require you to respond by typing y (yes) or n (no).
The system diagnostic utilities may issue messages if you run diagnostic tests on your system. See Using system diagnostics for more information about system diagnostics.
The systems management software generates alert messages for your system. Alert messages include information, status, warning, and failure messages for drive, temperature, fan, and power conditions. For more information, see the systems management software documentation.
Next steps

If you experience a problem with your system, run the system diagnostics before contacting Dell for technical assistance. The purpose of running system diagnostics is to test your system hardware without requiring additional equipment or risking data loss. If you are unable to fix the problem yourself, service and support personnel can use the diagnostics results to help you solve the problem.
The embedded system diagnostics provides a set of options for particular device groups or devices allowing you to:
If a major component or device in the system does not operate properly, running the embedded system diagnostics may indicate component failure.
The ePSA Pre-boot System Assessment window is displayed, listing all devices detected in the system. The diagnostics starts running the tests on all the detected devices.
The ePSA Pre-boot System Assessment window is displayed, listing all devices detected in the system. The diagnostics starts running the tests on all the detected devices.

Configuration Displays the configuration and status information of all detected devices.
Results Displays the results of all tests that are run.
System health Provides the current overview of the system performance.
Event log Displays a time-stamped log of the results of all tests run on the system. This is displayed if at least one event description is recorded.
For information about embedded system diagnostics, see the ePSA Diagnostics Guide (Notebooks, Desktops and Servers) at dell.com/support/home
Menu Description

System board jumper settings
Table 30. System board jumper settings
The password reset feature is enabled (pins 2–4). BIOS local access is unlocked at the next AC power cycle.
The password reset feature is disabled (pins 4–6).
The configuration settings are retained at the next system boot (pins 3–5).
The configuration settings are cleared at system boot (pins 1–3).
Jumper Setting Description


Figure 62. System board jumpers and connectors
1 J_BP_SIG1 Backplane signal connector 1
2 J_PS_2 PSU 2 connector
3 J_BP_SIG0 Backplane signal connector 0
4 J_BP0 Backplane power connector 0
5 J_SATA_CD Optical drive SATA connector, SATADOM connector
6 J_SATA_TBU Tape backup unit SATA connector
7 J_TBU SATADOM power connector
8 J_PS_1 PSU 1 connector
9 J_IDSDM Internal dual SD module connector
Item Connector Description

10 J_NDC Network daughter card connector
11 J_USB USB connector
12 J_VIDEO_REAR Video connector
13 J_COM1 Serial connector
14 J_IDRAC_RJ45 iDRAC 8 connector
15 J_CYC System identification connector
16 CYC_ID System identification button
17 J_TPM_MODULE Trusted Platform Module connector
18 J_RISER_2AX Riser 3 connector
19 J_RISER_1AX Riser 1 connector
20 J_RISER_2BX Riser 2 connector
21 J_RISER_1BX Riser 1 connector
22 J_RISER_3AX Riser 3 connector
23 J_QS Quick Sync bezel connector
24 J_RISER_3BX Riser 3 connector
25 J_SATA_B Internal SAS connector
26 J_STORAGE Mini PERC connector
27 J_USB_INT Internal USB connector
28 J_SATA_A Internal SAS connector
29 BAT Battery connector
30 CPU 2 Processor socket 2
31 J_BP3 Backplane power connector 3
32 B10, B6, B2, B9, B5, B1 Memory module sockets
33 J_BP_SIG2 Backplane signal connector 2
34 J_FAN2U_6 Cooling fan connector
35 J_FAN2U_5 Cooling fan connector
36 J_BP2 Backplane power connector 2
37 B3, B7, B11, B4, B8, B12 Memory module sockets
38 J_FAN2U_4 Cooling fan connector
39 A10, A6, A2, A9, A5, A1 Memory module sockets
40 J_FAN2U_3 Cooling fan connector
41 J_BP1 Backplane power connector
42 J_FAN2U_2 Cooling fan connector
Item Connector Description

43 A3, A7, A11, A4, A8, A12 Memory module sockets
44 J_FAN2U_1 Cooling fan connector
45 J_CTRL_PNL Control panel signal connector
46 CPU 1 Processor 1
47 J_FP_USB Front-panel USB connector
The system's software security features include a system password and a setup password. The password jumper enables these password features or disables them and clears any password(s) currently in use.
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Steps 1. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.
The existing passwords are not disabled (erased) until the system boots with the jumper on pins 2 and 4. However, before you assign a new system and/or setup password, you must move the jumper back to pins 4 and 6.
Item Connector Description

Processor type Two Intel Xeon processor E5-2600 v3 product family
AC power supply (per power supply)
Wattage 495 W, 750 W, or 1100 W
1908 BTU/hr maximum (495 W power supply)
2891 BTU/hr maximum (750 W power supply)
2843 BTU/hr maximum (750 W Titanium power supply)
4100 BTU/hr maximum (1100 W power supply)
4416 BTU/hr maximum (DC1100W power supply)
2891 BTU/hr maximum (750 W mixed mode power supply)
100–240 V AC, autoranging, 50/60 Hz
200–240 V AC, autoranging, 50/60 Hz, for 750 W Titanium power supply
Bus type PCI Express Generation 3
Expansion cards For a list of supported expansion cards, see Expansion cards and expansion-card risers
Expansion slots using riser card:
Riser 1 (Slot 1) One half-height, low-profile x8 link
(Slot 2) One half-height, low-profile x8 link
(Slot 3) One half-height, low-profile x8 link
Riser 2 (Slot 4) One full-height, full-length x16 link

(Slot 5) One full-height, full-length x8 link
Riser 3 (default) (Slot 6) One full-height, full-length x8 link
Architecture 1333 MT/s, 1600 MT/s, 1866 MT/s or 2133 MT/s DDR4 registered, load-reduced Error Correcting Code (ECC) DIMMs
Support for advanced ECC or memory optimized operation
Memory module sockets Twenty-four 288-pin
LRDIMMs 32 GB quad-ranked
RDIMMs 8 GB or 16 GB dual-ranked
Minimum RAM 64 GB with a dual processor
Maximum RAM Up to 768 GB with a dual processor
Up to 384 GB with a single processor
Twelve hard-drive systems Up to twelve 3.5 inch drives
Twenty-four hard-drive systems Up to twenty-four drives
NIC Four 1 Gbps, two 1 Gbps plus two 10 Gbps, or four 10 Gbps
Serial 9-pin, DTE, 16550-compatible
USB Two 4-pin, USB 3.0-compliant
External vFlash card One flash memory card slot with iDRAC8 Enterprise card

USB One 4-pin, USB 2.0-compliant
One USB management port/iDRAC Direct
USB One 4-pin, USB 3.0-compliant
Internal Dual SD Module Two flash memory card slots with the internal SD module
Video type Matrox G200eR2
Video memory 16 MB
Height 8.73 cm (3.44 inch)
Width 48.2 cm (18.98 inch)
Depth 75.58 cm (29.75 inch)
Storage –40°C to 65°C (–40°F to 149°F)
Continuous operation (for altitude less than 950 m or 3117 ft)
10°C to 35°C (50°F to 95°F) with no direct sunlight on the equipment.
Fresh air For information on fresh air, see Expanded Operating Temperature section.
Maximum temperature gradient (operating and storage)

Storage 5% to 95% RH with 33°C (91°F) maximumdew point. Atmosphere must be non-condensing at all times.
Operating 10% to 80% Relative Humidity with 29°C (84.2°F)maximum dew point.
Operating 0.26 Grms at 5 Hz to 350 Hz(all operation orientations).
Storage 1.88 Grms at 10 Hz to 500Hz for 15 min (all six sides tested).
Operating Six consecutively run shock pulses in the positive and negative x, y, and z axes of 40 G for up to 2.3 ms.
Storage Six consecutively run shock pulses in the positive and negative x, y, and z axes (one pulse on each side of the system) of 71 G for up to 2 ms.
Operating 3048 m (10,000 ft).
Storage 12,000 m (39,370 ft).
Up to 35 °C (95 °F) Maximum temperature is reduced by 1°C/300m (1°F/547 ft) above 950 m (3,117 ft).
35 °C to 40 °C (95 °F to 104 °F) Maximum temperature is reduced by 1°C/175m (1°F/319 ft) above 950 m (3,117 ft).
40 °C to 45 °C (104 °F to 113 °F) Maximum temperature is reduced by 1°C/125m (1°F/228 ft) above 950 m (3,117 ft).
NOTE: This section defines the limits to help avoid IT equipment damage and/or failure from particulates and gaseous contamination. If it is determined that levels of particulates or gaseous pollution are beyond the limits specified below and are the reason for the damage and/or failures to your equipment, it may be necessary for you tore-mediate the environmental conditions that are causing the damage and/or failures. Re-mediation of environmental conditions is the responsibility of the customer.
Air filtration Data center air filtration as defined by ISO Class 8 per ISO 14644-1 with a 95% upper confidence limit.

Air must be free of conductive dust, zinc whiskers, or other conductive particles.
Copper coupon corrosion rate
Silver coupon corrosion rate
Continuous operation 5°C to 40°C at 5% to 85% RH with 29°C dew point.
For temperatures between 35°C and 40°C, de- rate maximum allowable temperature by 1°C per 175 m above 950 m (1°F per 319 ft).
< 1% of annual operating hours –5°C to 45°C at 5% to 90% RH with 29°C dew point.

For temperatures between 40°C and 45°C, de- rate maximum allowable temperature by 1°C per 125 m above 950 m (1°F per 228 ft).
Physical

Contacting Dell
Dell provides several online and telephone-based support and service options. If you do not have an active Internet connection, you can find contact information on your purchase invoice, packing slip, bill, or Dell product catalog. Availability varies by country and product, and some services may not be available in your area. To contact Dell for sales, technical support, or customer-service issues:
a. Enter your system Service Tag in the Enter your Service Tag field. b. Click Submit.
The support page that lists the various support categories is displayed.
a. Select your product category. b. Select your product segment. c. Select your product.
The support page that lists the various support categories is displayed.
Your system is identified by a unique Express Service Code and Service Tag number. The Express Service Code and Service Tag are found on the front of the system by pulling out the information tag. Alternatively, the information may be on a sticker on the chassis of the system. This information is used by Dell to route support calls to the appropriate personnel.
If you have feedback for this document, write to documentation_feedback@dell.com. Alternatively, you can click on the Feedback link in any of the Dell documentation pages, fill out the form, and click Submit to send your feedback.
Use the Quick Resource Locator (QRL) to get immediate access to system information and how-to videos. This can be done by visiting dell.com/QRL or by using your smartphone or tablet and a model specific Quick Resource (QR) code located on your Dell system. To try out the QR code, scan the following image.