Dell XC730xd Web-scale Converged Appliance Owner's Manualp.3About your systemp.8Supported configurationp.8Front panel features and indicatorsp.8Diagnostic indicatorsp.10Hard drive indicator codesp.12iDRAC Direct LED indicator codesp.13Back-panel features and indicatorsp.14NIC indicator codesp.16Power indicator codesp.16Documentation matrixp.19Dell documentationp.20Nutanix documentationp.20Quick Resource Locatorp.21Performing initial system configurationp.23Setting up your systemp.23Methods of setting up and configuring the iDRAC IP addressp.23Logging in to iDRACp.23Installing the operating systemp.24Remote managementp.24Downloading and installing drivers and firmwarep.24Pre-operating system management applicationsp.25Navigation keysp.25About System Setupp.26Entering System Setupp.26System Setup Main Menup.27Editing system BIOS screen settingsp.27Editing system informationp.28Editing memory settingsp.28Editing processor settingsp.29Editing SATA Settingsp.31Editing boot settings screenp.34Editing network settingsp.34Editing integrated devices detailsp.35Editing serial communication settingsp.36Editing system profilep.37Editing system securityp.39Editing miscellaneous settingsp.41About Boot Managerp.42Entering Boot Managerp.42Boot Manager main menup.42Changing the boot orderp.43Choosing the system boot modep.43Assigning a system and setup passwordp.43Deleting or changing an existing system password and setup passwordp.44Installing and removing system componentsp.45Safety instructionsp.45Before working inside your systemp.45After working inside your systemp.45Recommended toolsp.46Front bezelp.46Removing the front bezelp.46Installing the front bezelp.47Removing the system coverp.47Installing the system coverp.48Inside the systemp.49Cooling shroudp.50Removing the cooling shroudp.51Installing the cooling shroudp.51Cooling fansp.52Removing a cooling fanp.52Installing a cooling fanp.53Cooling-fan assemblyp.54Removing the cooling-fan assemblyp.54Installing the cooling-fan assemblyp.55System memoryp.56General memory module installation guidelinesp.59Sample memory configurationsp.59Removing memory modulesp.60Installing memory modulesp.62SATADOMp.63Removing the SATADOMp.64Installing the SATADOMp.65Heat sinks and processorsp.66Removing a processorp.66Installing a processorp.71PCIe card holderp.73Removing the PCIe card holderp.73Installing the PCIe card holderp.74Opening and closing the PCIe card holder latchp.75Cable retention bracketp.76Removing the cable retention bracketp.76Installing the cable retention bracketp.77Integrated storage controller cardp.77Removing the integrated storage controller cardp.77Installing the integrated storage controller cardp.79Expansion cards and expansion-card risersp.80Expansion card installation guidelinesp.80Removing an expansion card from expansion-card riser 2 or 3p.81Installing an expansion card into the expansion-card riser 2 or 3p.82Removing an expansion card from the expansion-card riser 1p.83Installing an expansion card into the expansion-card riser 1p.84Removing expansion-card risersp.85Installing expansion-card risersp.92Internal dual SD modulep.92Removing an internal SD cardp.92Installing an internal SD cardp.93Removing the internal dual SD modulep.93Installing the internal dual SD modulep.95Network daughter cardp.95Removing the network daughter cardp.95Installing the network daughter cardp.97System batteryp.97Replacing the system batteryp.97Power supply unitsp.99Hot Spare featurep.100Removing the power supply unit blankp.100Installing the power supply unit blankp.101Removing an AC power supply unitp.101Installing an AC power supply unitp.102Wiring instructions for a DC power supply unitp.103Removing a DC power supply unitp.104Installing a DC power supply unitp.105System boardp.105Removing the system boardp.105Installing the system boardp.107Trusted Platform Modulep.110Installing the Trusted Platform Modulep.110Re-enabling the TPM for BitLocker usersp.111Re-enabling the TPM for TXT usersp.111Hard drivesp.112Removing a 2.5 inch hard-drive blankp.112Installing a 2.5 inch hard-drive blankp.113Removing a 2.5 inch hard-drive blank (back)p.113Installing a 2.5 inch hard-drive blank (back)p.114Removing a 3.5 inch hard-drive blankp.114Installing a 3.5 inch hard-drive blankp.115Removing a hot-swap hard drivep.115Installing a hot-swap hard drivep.117Removing a hard drive from a hard-drive carrierp.117Installing a hard drive into a hard-drive carrierp.118Hard-drive backplanep.118Removing the hard-drive backplanep.118Installing the hard-drive backplanep.122Removing the optional hard-drive backplane (back)p.123Removing the control panelp.125Installing the control panelp.126Removing the I/O panelp.127Installing the I/O panelp.128Removing the hard-drive backplane from the hard-drive trayp.129Installing the hard-drive backplane in the hard-drive trayp.130Troubleshooting your systemp.132Safety first—for you and your systemp.132Troubleshooting system startup failurep.132Troubleshooting external connectionsp.132Troubleshooting the video subsystemp.132Troubleshooting a USB devicep.132Troubleshooting iDRAC Direct (USB XML configuration)p.133Troubleshooting iDRAC Direct (laptop connection)p.134Troubleshooting a serial I/O devicep.134Troubleshooting a NICp.134Troubleshooting a wet systemp.135Troubleshooting a damaged systemp.136Troubleshooting the system batteryp.136Troubleshooting power supply unitsp.137Power source problemsp.137Power supply unit problemsp.137Troubleshooting cooling problemsp.138Troubleshooting cooling fansp.138Troubleshooting system memoryp.139Troubleshooting an SD cardp.140Troubleshooting a hard drivep.140Troubleshooting a storage controllerp.141Troubleshooting expansion cardsp.142Troubleshooting processorsp.142System messagesp.143Warning messagesp.143Diagnostic messagesp.143Alert messagesp.143Using system diagnosticsp.144Dell Embedded System Diagnosticsp.144When to use the Embedded System Diagnosticsp.144Running the Embedded System Diagnostics from Boot Managerp.144Running the Embedded System Diagnostics from the Dell Lifecycle Controllerp.144System diagnostic controlsp.145Jumpers and connectorsp.146System board jumper settingsp.146System board connectorsp.147Disabling a forgotten passwordp.149Technical specificationsp.150Getting helpp.156Contacting Dellp.156Locating your system Service Tagp.156Documentation feedbackp.156Quick Resource Locatorp.156
Page 1 of the Dell XC730xd user manual — Dell XC730xd Web-scale Converged Appliance Owner's Manual
Page 1 · click to enlarge
Page 1

Dell XC730xd Web-scale Converged Appliance Owner's Manual

Page 2 of the Dell XC730xd user manual — Notes, Cautions, and Warnings
Page 2 · click to enlarge
Page 2

Notes, Cautions, and Warnings

Copyright © 2015 Dell Inc. All rights reserved. This product is protected by U.S. and international copyright and intellectual property laws. Dell™ and the Dell logo are trademarks of Dell Inc. in the United States and/or other jurisdictions. All other marks and names mentioned herein may be trademarks of their respective companies.

Rev. A00

Page 3 of the Dell XC730xd user manual — Table of contents
Page 3 · click to enlarge
Page 3

Table of contents

Dell XC730xd Web-scale Converged Appliance Owner's Manualp.3About your systemp.8Supported configurationp.8Front panel features and indicatorsp.8Diagnostic indicatorsp.10Hard drive indicator codesp.12iDRAC Direct LED indicator codesp.13Back-panel features and indicatorsp.14NIC indicator codesp.16Power indicator codesp.16Documentation matrixp.19Dell documentationp.20Nutanix documentationp.20Quick Resource Locatorp.21Performing initial system configurationp.23Setting up your systemp.23Methods of setting up and configuring the iDRAC IP addressp.23Logging in to iDRACp.23Installing the operating systemp.24Remote managementp.24Downloading and installing drivers and firmwarep.24Pre-operating system management applicationsp.25Navigation keysp.25About System Setupp.26Entering System Setupp.26System Setup Main Menup.27Editing system BIOS screen settingsp.27Editing system informationp.28Editing memory settingsp.28Editing processor settingsp.29Editing SATA Settingsp.31Editing boot settings screenp.34Editing network settingsp.34Editing integrated devices detailsp.35Editing serial communication settingsp.36Editing system profilep.37Editing system securityp.39Editing miscellaneous settingsp.41About Boot Managerp.42Entering Boot Managerp.42Boot Manager main menup.42Changing the boot orderp.43Choosing the system boot modep.43Assigning a system and setup passwordp.43Deleting or changing an existing system password and setup passwordp.44Installing and removing system componentsp.45Safety instructionsp.45Before working inside your systemp.45After working inside your systemp.45Recommended toolsp.46Front bezelp.46Removing the front bezelp.46Installing the front bezelp.47Removing the system coverp.47Installing the system coverp.48Inside the systemp.49Cooling shroudp.50Removing the cooling shroudp.51Installing the cooling shroudp.51Cooling fansp.52Removing a cooling fanp.52Installing a cooling fanp.53Cooling-fan assemblyp.54Removing the cooling-fan assemblyp.54Installing the cooling-fan assemblyp.55System memoryp.56General memory module installation guidelinesp.59Sample memory configurationsp.59Removing memory modulesp.60Installing memory modulesp.62SATADOMp.63Removing the SATADOMp.64Installing the SATADOMp.65Heat sinks and processorsp.66Removing a processorp.66Installing a processorp.71PCIe card holderp.73Removing the PCIe card holderp.73Installing the PCIe card holderp.74Opening and closing the PCIe card holder latchp.75Cable retention bracketp.76Removing the cable retention bracketp.76Installing the cable retention bracketp.77Integrated storage controller cardp.77Removing the integrated storage controller cardp.77Installing the integrated storage controller cardp.79Expansion cards and expansion-card risersp.80Expansion card installation guidelinesp.80Removing an expansion card from expansion-card riser 2 or 3p.81Installing an expansion card into the expansion-card riser 2 or 3p.82Removing an expansion card from the expansion-card riser 1p.83Installing an expansion card into the expansion-card riser 1p.84Removing expansion-card risersp.85Installing expansion-card risersp.92Internal dual SD modulep.92Removing an internal SD cardp.92Installing an internal SD cardp.93Removing the internal dual SD modulep.93Installing the internal dual SD modulep.95Network daughter cardp.95Removing the network daughter cardp.95Installing the network daughter cardp.97System batteryp.97Replacing the system batteryp.97Power supply unitsp.99Hot Spare featurep.100Removing the power supply unit blankp.100Installing the power supply unit blankp.101Removing an AC power supply unitp.101Installing an AC power supply unitp.102Wiring instructions for a DC power supply unitp.103Removing a DC power supply unitp.104Installing a DC power supply unitp.105System boardp.105Removing the system boardp.105Installing the system boardp.107Trusted Platform Modulep.110Installing the Trusted Platform Modulep.110Re-enabling the TPM for BitLocker usersp.111Re-enabling the TPM for TXT usersp.111Hard drivesp.112Removing a 2.5 inch hard-drive blankp.112Installing a 2.5 inch hard-drive blankp.113Removing a 2.5 inch hard-drive blank (back)p.113Installing a 2.5 inch hard-drive blank (back)p.114Removing a 3.5 inch hard-drive blankp.114Installing a 3.5 inch hard-drive blankp.115Removing a hot-swap hard drivep.115Installing a hot-swap hard drivep.117Removing a hard drive from a hard-drive carrierp.117Installing a hard drive into a hard-drive carrierp.118Hard-drive backplanep.118Removing the hard-drive backplanep.118Installing the hard-drive backplanep.122Removing the optional hard-drive backplane (back)p.123Removing the control panelp.125Installing the control panelp.126Removing the I/O panelp.127Installing the I/O panelp.128Removing the hard-drive backplane from the hard-drive trayp.129Installing the hard-drive backplane in the hard-drive trayp.130Troubleshooting your systemp.132Safety first—for you and your systemp.132Troubleshooting system startup failurep.132Troubleshooting external connectionsp.132Troubleshooting the video subsystemp.132Troubleshooting a USB devicep.132Troubleshooting iDRAC Direct (USB XML configuration)p.133Troubleshooting iDRAC Direct (laptop connection)p.134Troubleshooting a serial I/O devicep.134Troubleshooting a NICp.134Troubleshooting a wet systemp.135Troubleshooting a damaged systemp.136Troubleshooting the system batteryp.136Troubleshooting power supply unitsp.137Power source problemsp.137Power supply unit problemsp.137Troubleshooting cooling problemsp.138Troubleshooting cooling fansp.138Troubleshooting system memoryp.139Troubleshooting an SD cardp.140Troubleshooting a hard drivep.140Troubleshooting a storage controllerp.141Troubleshooting expansion cardsp.142Troubleshooting processorsp.142System messagesp.143Warning messagesp.143Diagnostic messagesp.143Alert messagesp.143Using system diagnosticsp.144Dell Embedded System Diagnosticsp.144When to use the Embedded System Diagnosticsp.144Running the Embedded System Diagnostics from Boot Managerp.144Running the Embedded System Diagnostics from the Dell Lifecycle Controllerp.144System diagnostic controlsp.145Jumpers and connectorsp.146System board jumper settingsp.146System board connectorsp.147Disabling a forgotten passwordp.149Technical specificationsp.150Getting helpp.156Contacting Dellp.156Locating your system Service Tagp.156Documentation feedbackp.156Quick Resource Locatorp.156
Page 4 of the Dell XC730xd user manual — Table of contents
Page 4 · click to enlarge
Page 4

Table of contents

Dell XC730xd Web-scale Converged Appliance Owner's Manualp.3About your systemp.8Supported configurationp.8Front panel features and indicatorsp.8Diagnostic indicatorsp.10Hard drive indicator codesp.12iDRAC Direct LED indicator codesp.13Back-panel features and indicatorsp.14NIC indicator codesp.16Power indicator codesp.16Documentation matrixp.19Dell documentationp.20Nutanix documentationp.20Quick Resource Locatorp.21Performing initial system configurationp.23Setting up your systemp.23Methods of setting up and configuring the iDRAC IP addressp.23Logging in to iDRACp.23Installing the operating systemp.24Remote managementp.24Downloading and installing drivers and firmwarep.24Pre-operating system management applicationsp.25Navigation keysp.25About System Setupp.26Entering System Setupp.26System Setup Main Menup.27Editing system BIOS screen settingsp.27Editing system informationp.28Editing memory settingsp.28Editing processor settingsp.29Editing SATA Settingsp.31Editing boot settings screenp.34Editing network settingsp.34Editing integrated devices detailsp.35Editing serial communication settingsp.36Editing system profilep.37Editing system securityp.39Editing miscellaneous settingsp.41About Boot Managerp.42Entering Boot Managerp.42Boot Manager main menup.42Changing the boot orderp.43Choosing the system boot modep.43Assigning a system and setup passwordp.43Deleting or changing an existing system password and setup passwordp.44Installing and removing system componentsp.45Safety instructionsp.45Before working inside your systemp.45After working inside your systemp.45Recommended toolsp.46Front bezelp.46Removing the front bezelp.46Installing the front bezelp.47Removing the system coverp.47Installing the system coverp.48Inside the systemp.49Cooling shroudp.50Removing the cooling shroudp.51Installing the cooling shroudp.51Cooling fansp.52Removing a cooling fanp.52Installing a cooling fanp.53Cooling-fan assemblyp.54Removing the cooling-fan assemblyp.54Installing the cooling-fan assemblyp.55System memoryp.56General memory module installation guidelinesp.59Sample memory configurationsp.59Removing memory modulesp.60Installing memory modulesp.62SATADOMp.63Removing the SATADOMp.64Installing the SATADOMp.65Heat sinks and processorsp.66Removing a processorp.66Installing a processorp.71PCIe card holderp.73Removing the PCIe card holderp.73Installing the PCIe card holderp.74Opening and closing the PCIe card holder latchp.75Cable retention bracketp.76Removing the cable retention bracketp.76Installing the cable retention bracketp.77Integrated storage controller cardp.77Removing the integrated storage controller cardp.77Installing the integrated storage controller cardp.79Expansion cards and expansion-card risersp.80Expansion card installation guidelinesp.80Removing an expansion card from expansion-card riser 2 or 3p.81Installing an expansion card into the expansion-card riser 2 or 3p.82Removing an expansion card from the expansion-card riser 1p.83Installing an expansion card into the expansion-card riser 1p.84Removing expansion-card risersp.85Installing expansion-card risersp.92Internal dual SD modulep.92Removing an internal SD cardp.92Installing an internal SD cardp.93Removing the internal dual SD modulep.93Installing the internal dual SD modulep.95Network daughter cardp.95Removing the network daughter cardp.95Installing the network daughter cardp.97System batteryp.97Replacing the system batteryp.97Power supply unitsp.99Hot Spare featurep.100Removing the power supply unit blankp.100Installing the power supply unit blankp.101Removing an AC power supply unitp.101Installing an AC power supply unitp.102Wiring instructions for a DC power supply unitp.103Removing a DC power supply unitp.104Installing a DC power supply unitp.105System boardp.105Removing the system boardp.105Installing the system boardp.107Trusted Platform Modulep.110Installing the Trusted Platform Modulep.110Re-enabling the TPM for BitLocker usersp.111Re-enabling the TPM for TXT usersp.111Hard drivesp.112Removing a 2.5 inch hard-drive blankp.112Installing a 2.5 inch hard-drive blankp.113Removing a 2.5 inch hard-drive blank (back)p.113Installing a 2.5 inch hard-drive blank (back)p.114Removing a 3.5 inch hard-drive blankp.114Installing a 3.5 inch hard-drive blankp.115Removing a hot-swap hard drivep.115Installing a hot-swap hard drivep.117Removing a hard drive from a hard-drive carrierp.117Installing a hard drive into a hard-drive carrierp.118Hard-drive backplanep.118Removing the hard-drive backplanep.118Installing the hard-drive backplanep.122Removing the optional hard-drive backplane (back)p.123Removing the control panelp.125Installing the control panelp.126Removing the I/O panelp.127Installing the I/O panelp.128Removing the hard-drive backplane from the hard-drive trayp.129Installing the hard-drive backplane in the hard-drive trayp.130Troubleshooting your systemp.132Safety first—for you and your systemp.132Troubleshooting system startup failurep.132Troubleshooting external connectionsp.132Troubleshooting the video subsystemp.132Troubleshooting a USB devicep.132Troubleshooting iDRAC Direct (USB XML configuration)p.133Troubleshooting iDRAC Direct (laptop connection)p.134Troubleshooting a serial I/O devicep.134Troubleshooting a NICp.134Troubleshooting a wet systemp.135Troubleshooting a damaged systemp.136Troubleshooting the system batteryp.136Troubleshooting power supply unitsp.137Power source problemsp.137Power supply unit problemsp.137Troubleshooting cooling problemsp.138Troubleshooting cooling fansp.138Troubleshooting system memoryp.139Troubleshooting an SD cardp.140Troubleshooting a hard drivep.140Troubleshooting a storage controllerp.141Troubleshooting expansion cardsp.142Troubleshooting processorsp.142System messagesp.143Warning messagesp.143Diagnostic messagesp.143Alert messagesp.143Using system diagnosticsp.144Dell Embedded System Diagnosticsp.144When to use the Embedded System Diagnosticsp.144Running the Embedded System Diagnostics from Boot Managerp.144Running the Embedded System Diagnostics from the Dell Lifecycle Controllerp.144System diagnostic controlsp.145Jumpers and connectorsp.146System board jumper settingsp.146System board connectorsp.147Disabling a forgotten passwordp.149Technical specificationsp.150Getting helpp.156Contacting Dellp.156Locating your system Service Tagp.156Documentation feedbackp.156Quick Resource Locatorp.156
Page 5 of the Dell XC730xd user manual — Table of contents
Page 5 · click to enlarge
Page 5

Table of contents

Dell XC730xd Web-scale Converged Appliance Owner's Manualp.3About your systemp.8Supported configurationp.8Front panel features and indicatorsp.8Diagnostic indicatorsp.10Hard drive indicator codesp.12iDRAC Direct LED indicator codesp.13Back-panel features and indicatorsp.14NIC indicator codesp.16Power indicator codesp.16Documentation matrixp.19Dell documentationp.20Nutanix documentationp.20Quick Resource Locatorp.21Performing initial system configurationp.23Setting up your systemp.23Methods of setting up and configuring the iDRAC IP addressp.23Logging in to iDRACp.23Installing the operating systemp.24Remote managementp.24Downloading and installing drivers and firmwarep.24Pre-operating system management applicationsp.25Navigation keysp.25About System Setupp.26Entering System Setupp.26System Setup Main Menup.27Editing system BIOS screen settingsp.27Editing system informationp.28Editing memory settingsp.28Editing processor settingsp.29Editing SATA Settingsp.31Editing boot settings screenp.34Editing network settingsp.34Editing integrated devices detailsp.35Editing serial communication settingsp.36Editing system profilep.37Editing system securityp.39Editing miscellaneous settingsp.41About Boot Managerp.42Entering Boot Managerp.42Boot Manager main menup.42Changing the boot orderp.43Choosing the system boot modep.43Assigning a system and setup passwordp.43Deleting or changing an existing system password and setup passwordp.44Installing and removing system componentsp.45Safety instructionsp.45Before working inside your systemp.45After working inside your systemp.45Recommended toolsp.46Front bezelp.46Removing the front bezelp.46Installing the front bezelp.47Removing the system coverp.47Installing the system coverp.48Inside the systemp.49Cooling shroudp.50Removing the cooling shroudp.51Installing the cooling shroudp.51Cooling fansp.52Removing a cooling fanp.52Installing a cooling fanp.53Cooling-fan assemblyp.54Removing the cooling-fan assemblyp.54Installing the cooling-fan assemblyp.55System memoryp.56General memory module installation guidelinesp.59Sample memory configurationsp.59Removing memory modulesp.60Installing memory modulesp.62SATADOMp.63Removing the SATADOMp.64Installing the SATADOMp.65Heat sinks and processorsp.66Removing a processorp.66Installing a processorp.71PCIe card holderp.73Removing the PCIe card holderp.73Installing the PCIe card holderp.74Opening and closing the PCIe card holder latchp.75Cable retention bracketp.76Removing the cable retention bracketp.76Installing the cable retention bracketp.77Integrated storage controller cardp.77Removing the integrated storage controller cardp.77Installing the integrated storage controller cardp.79Expansion cards and expansion-card risersp.80Expansion card installation guidelinesp.80Removing an expansion card from expansion-card riser 2 or 3p.81Installing an expansion card into the expansion-card riser 2 or 3p.82Removing an expansion card from the expansion-card riser 1p.83Installing an expansion card into the expansion-card riser 1p.84Removing expansion-card risersp.85Installing expansion-card risersp.92Internal dual SD modulep.92Removing an internal SD cardp.92Installing an internal SD cardp.93Removing the internal dual SD modulep.93Installing the internal dual SD modulep.95Network daughter cardp.95Removing the network daughter cardp.95Installing the network daughter cardp.97System batteryp.97Replacing the system batteryp.97Power supply unitsp.99Hot Spare featurep.100Removing the power supply unit blankp.100Installing the power supply unit blankp.101Removing an AC power supply unitp.101Installing an AC power supply unitp.102Wiring instructions for a DC power supply unitp.103Removing a DC power supply unitp.104Installing a DC power supply unitp.105System boardp.105Removing the system boardp.105Installing the system boardp.107Trusted Platform Modulep.110Installing the Trusted Platform Modulep.110Re-enabling the TPM for BitLocker usersp.111Re-enabling the TPM for TXT usersp.111Hard drivesp.112Removing a 2.5 inch hard-drive blankp.112Installing a 2.5 inch hard-drive blankp.113Removing a 2.5 inch hard-drive blank (back)p.113Installing a 2.5 inch hard-drive blank (back)p.114Removing a 3.5 inch hard-drive blankp.114Installing a 3.5 inch hard-drive blankp.115Removing a hot-swap hard drivep.115Installing a hot-swap hard drivep.117Removing a hard drive from a hard-drive carrierp.117Installing a hard drive into a hard-drive carrierp.118Hard-drive backplanep.118Removing the hard-drive backplanep.118Installing the hard-drive backplanep.122Removing the optional hard-drive backplane (back)p.123Removing the control panelp.125Installing the control panelp.126Removing the I/O panelp.127Installing the I/O panelp.128Removing the hard-drive backplane from the hard-drive trayp.129Installing the hard-drive backplane in the hard-drive trayp.130Troubleshooting your systemp.132Safety first—for you and your systemp.132Troubleshooting system startup failurep.132Troubleshooting external connectionsp.132Troubleshooting the video subsystemp.132Troubleshooting a USB devicep.132Troubleshooting iDRAC Direct (USB XML configuration)p.133Troubleshooting iDRAC Direct (laptop connection)p.134Troubleshooting a serial I/O devicep.134Troubleshooting a NICp.134Troubleshooting a wet systemp.135Troubleshooting a damaged systemp.136Troubleshooting the system batteryp.136Troubleshooting power supply unitsp.137Power source problemsp.137Power supply unit problemsp.137Troubleshooting cooling problemsp.138Troubleshooting cooling fansp.138Troubleshooting system memoryp.139Troubleshooting an SD cardp.140Troubleshooting a hard drivep.140Troubleshooting a storage controllerp.141Troubleshooting expansion cardsp.142Troubleshooting processorsp.142System messagesp.143Warning messagesp.143Diagnostic messagesp.143Alert messagesp.143Using system diagnosticsp.144Dell Embedded System Diagnosticsp.144When to use the Embedded System Diagnosticsp.144Running the Embedded System Diagnostics from Boot Managerp.144Running the Embedded System Diagnostics from the Dell Lifecycle Controllerp.144System diagnostic controlsp.145Jumpers and connectorsp.146System board jumper settingsp.146System board connectorsp.147Disabling a forgotten passwordp.149Technical specificationsp.150Getting helpp.156Contacting Dellp.156Locating your system Service Tagp.156Documentation feedbackp.156Quick Resource Locatorp.156
Page 6 of the Dell XC730xd user manual — Table of contents
Page 6 · click to enlarge
Page 6

Table of contents

Dell XC730xd Web-scale Converged Appliance Owner's Manualp.3About your systemp.8Supported configurationp.8Front panel features and indicatorsp.8Diagnostic indicatorsp.10Hard drive indicator codesp.12iDRAC Direct LED indicator codesp.13Back-panel features and indicatorsp.14NIC indicator codesp.16Power indicator codesp.16Documentation matrixp.19Dell documentationp.20Nutanix documentationp.20Quick Resource Locatorp.21Performing initial system configurationp.23Setting up your systemp.23Methods of setting up and configuring the iDRAC IP addressp.23Logging in to iDRACp.23Installing the operating systemp.24Remote managementp.24Downloading and installing drivers and firmwarep.24Pre-operating system management applicationsp.25Navigation keysp.25About System Setupp.26Entering System Setupp.26System Setup Main Menup.27Editing system BIOS screen settingsp.27Editing system informationp.28Editing memory settingsp.28Editing processor settingsp.29Editing SATA Settingsp.31Editing boot settings screenp.34Editing network settingsp.34Editing integrated devices detailsp.35Editing serial communication settingsp.36Editing system profilep.37Editing system securityp.39Editing miscellaneous settingsp.41About Boot Managerp.42Entering Boot Managerp.42Boot Manager main menup.42Changing the boot orderp.43Choosing the system boot modep.43Assigning a system and setup passwordp.43Deleting or changing an existing system password and setup passwordp.44Installing and removing system componentsp.45Safety instructionsp.45Before working inside your systemp.45After working inside your systemp.45Recommended toolsp.46Front bezelp.46Removing the front bezelp.46Installing the front bezelp.47Removing the system coverp.47Installing the system coverp.48Inside the systemp.49Cooling shroudp.50Removing the cooling shroudp.51Installing the cooling shroudp.51Cooling fansp.52Removing a cooling fanp.52Installing a cooling fanp.53Cooling-fan assemblyp.54Removing the cooling-fan assemblyp.54Installing the cooling-fan assemblyp.55System memoryp.56General memory module installation guidelinesp.59Sample memory configurationsp.59Removing memory modulesp.60Installing memory modulesp.62SATADOMp.63Removing the SATADOMp.64Installing the SATADOMp.65Heat sinks and processorsp.66Removing a processorp.66Installing a processorp.71PCIe card holderp.73Removing the PCIe card holderp.73Installing the PCIe card holderp.74Opening and closing the PCIe card holder latchp.75Cable retention bracketp.76Removing the cable retention bracketp.76Installing the cable retention bracketp.77Integrated storage controller cardp.77Removing the integrated storage controller cardp.77Installing the integrated storage controller cardp.79Expansion cards and expansion-card risersp.80Expansion card installation guidelinesp.80Removing an expansion card from expansion-card riser 2 or 3p.81Installing an expansion card into the expansion-card riser 2 or 3p.82Removing an expansion card from the expansion-card riser 1p.83Installing an expansion card into the expansion-card riser 1p.84Removing expansion-card risersp.85Installing expansion-card risersp.92Internal dual SD modulep.92Removing an internal SD cardp.92Installing an internal SD cardp.93Removing the internal dual SD modulep.93Installing the internal dual SD modulep.95Network daughter cardp.95Removing the network daughter cardp.95Installing the network daughter cardp.97System batteryp.97Replacing the system batteryp.97Power supply unitsp.99Hot Spare featurep.100Removing the power supply unit blankp.100Installing the power supply unit blankp.101Removing an AC power supply unitp.101Installing an AC power supply unitp.102Wiring instructions for a DC power supply unitp.103Removing a DC power supply unitp.104Installing a DC power supply unitp.105System boardp.105Removing the system boardp.105Installing the system boardp.107Trusted Platform Modulep.110Installing the Trusted Platform Modulep.110Re-enabling the TPM for BitLocker usersp.111Re-enabling the TPM for TXT usersp.111Hard drivesp.112Removing a 2.5 inch hard-drive blankp.112Installing a 2.5 inch hard-drive blankp.113Removing a 2.5 inch hard-drive blank (back)p.113Installing a 2.5 inch hard-drive blank (back)p.114Removing a 3.5 inch hard-drive blankp.114Installing a 3.5 inch hard-drive blankp.115Removing a hot-swap hard drivep.115Installing a hot-swap hard drivep.117Removing a hard drive from a hard-drive carrierp.117Installing a hard drive into a hard-drive carrierp.118Hard-drive backplanep.118Removing the hard-drive backplanep.118Installing the hard-drive backplanep.122Removing the optional hard-drive backplane (back)p.123Removing the control panelp.125Installing the control panelp.126Removing the I/O panelp.127Installing the I/O panelp.128Removing the hard-drive backplane from the hard-drive trayp.129Installing the hard-drive backplane in the hard-drive trayp.130Troubleshooting your systemp.132Safety first—for you and your systemp.132Troubleshooting system startup failurep.132Troubleshooting external connectionsp.132Troubleshooting the video subsystemp.132Troubleshooting a USB devicep.132Troubleshooting iDRAC Direct (USB XML configuration)p.133Troubleshooting iDRAC Direct (laptop connection)p.134Troubleshooting a serial I/O devicep.134Troubleshooting a NICp.134Troubleshooting a wet systemp.135Troubleshooting a damaged systemp.136Troubleshooting the system batteryp.136Troubleshooting power supply unitsp.137Power source problemsp.137Power supply unit problemsp.137Troubleshooting cooling problemsp.138Troubleshooting cooling fansp.138Troubleshooting system memoryp.139Troubleshooting an SD cardp.140Troubleshooting a hard drivep.140Troubleshooting a storage controllerp.141Troubleshooting expansion cardsp.142Troubleshooting processorsp.142System messagesp.143Warning messagesp.143Diagnostic messagesp.143Alert messagesp.143Using system diagnosticsp.144Dell Embedded System Diagnosticsp.144When to use the Embedded System Diagnosticsp.144Running the Embedded System Diagnostics from Boot Managerp.144Running the Embedded System Diagnostics from the Dell Lifecycle Controllerp.144System diagnostic controlsp.145Jumpers and connectorsp.146System board jumper settingsp.146System board connectorsp.147Disabling a forgotten passwordp.149Technical specificationsp.150Getting helpp.156Contacting Dellp.156Locating your system Service Tagp.156Documentation feedbackp.156Quick Resource Locatorp.156
Page 7 of the Dell XC730xd user manual — Table of contents
Page 7 · click to enlarge
Page 7

Table of contents

Dell XC730xd Web-scale Converged Appliance Owner's Manualp.3About your systemp.8Supported configurationp.8Front panel features and indicatorsp.8Diagnostic indicatorsp.10Hard drive indicator codesp.12iDRAC Direct LED indicator codesp.13Back-panel features and indicatorsp.14NIC indicator codesp.16Power indicator codesp.16Documentation matrixp.19Dell documentationp.20Nutanix documentationp.20Quick Resource Locatorp.21Performing initial system configurationp.23Setting up your systemp.23Methods of setting up and configuring the iDRAC IP addressp.23Logging in to iDRACp.23Installing the operating systemp.24Remote managementp.24Downloading and installing drivers and firmwarep.24Pre-operating system management applicationsp.25Navigation keysp.25About System Setupp.26Entering System Setupp.26System Setup Main Menup.27Editing system BIOS screen settingsp.27Editing system informationp.28Editing memory settingsp.28Editing processor settingsp.29Editing SATA Settingsp.31Editing boot settings screenp.34Editing network settingsp.34Editing integrated devices detailsp.35Editing serial communication settingsp.36Editing system profilep.37Editing system securityp.39Editing miscellaneous settingsp.41About Boot Managerp.42Entering Boot Managerp.42Boot Manager main menup.42Changing the boot orderp.43Choosing the system boot modep.43Assigning a system and setup passwordp.43Deleting or changing an existing system password and setup passwordp.44Installing and removing system componentsp.45Safety instructionsp.45Before working inside your systemp.45After working inside your systemp.45Recommended toolsp.46Front bezelp.46Removing the front bezelp.46Installing the front bezelp.47Removing the system coverp.47Installing the system coverp.48Inside the systemp.49Cooling shroudp.50Removing the cooling shroudp.51Installing the cooling shroudp.51Cooling fansp.52Removing a cooling fanp.52Installing a cooling fanp.53Cooling-fan assemblyp.54Removing the cooling-fan assemblyp.54Installing the cooling-fan assemblyp.55System memoryp.56General memory module installation guidelinesp.59Sample memory configurationsp.59Removing memory modulesp.60Installing memory modulesp.62SATADOMp.63Removing the SATADOMp.64Installing the SATADOMp.65Heat sinks and processorsp.66Removing a processorp.66Installing a processorp.71PCIe card holderp.73Removing the PCIe card holderp.73Installing the PCIe card holderp.74Opening and closing the PCIe card holder latchp.75Cable retention bracketp.76Removing the cable retention bracketp.76Installing the cable retention bracketp.77Integrated storage controller cardp.77Removing the integrated storage controller cardp.77Installing the integrated storage controller cardp.79Expansion cards and expansion-card risersp.80Expansion card installation guidelinesp.80Removing an expansion card from expansion-card riser 2 or 3p.81Installing an expansion card into the expansion-card riser 2 or 3p.82Removing an expansion card from the expansion-card riser 1p.83Installing an expansion card into the expansion-card riser 1p.84Removing expansion-card risersp.85Installing expansion-card risersp.92Internal dual SD modulep.92Removing an internal SD cardp.92Installing an internal SD cardp.93Removing the internal dual SD modulep.93Installing the internal dual SD modulep.95Network daughter cardp.95Removing the network daughter cardp.95Installing the network daughter cardp.97System batteryp.97Replacing the system batteryp.97Power supply unitsp.99Hot Spare featurep.100Removing the power supply unit blankp.100Installing the power supply unit blankp.101Removing an AC power supply unitp.101Installing an AC power supply unitp.102Wiring instructions for a DC power supply unitp.103Removing a DC power supply unitp.104Installing a DC power supply unitp.105System boardp.105Removing the system boardp.105Installing the system boardp.107Trusted Platform Modulep.110Installing the Trusted Platform Modulep.110Re-enabling the TPM for BitLocker usersp.111Re-enabling the TPM for TXT usersp.111Hard drivesp.112Removing a 2.5 inch hard-drive blankp.112Installing a 2.5 inch hard-drive blankp.113Removing a 2.5 inch hard-drive blank (back)p.113Installing a 2.5 inch hard-drive blank (back)p.114Removing a 3.5 inch hard-drive blankp.114Installing a 3.5 inch hard-drive blankp.115Removing a hot-swap hard drivep.115Installing a hot-swap hard drivep.117Removing a hard drive from a hard-drive carrierp.117Installing a hard drive into a hard-drive carrierp.118Hard-drive backplanep.118Removing the hard-drive backplanep.118Installing the hard-drive backplanep.122Removing the optional hard-drive backplane (back)p.123Removing the control panelp.125Installing the control panelp.126Removing the I/O panelp.127Installing the I/O panelp.128Removing the hard-drive backplane from the hard-drive trayp.129Installing the hard-drive backplane in the hard-drive trayp.130Troubleshooting your systemp.132Safety first—for you and your systemp.132Troubleshooting system startup failurep.132Troubleshooting external connectionsp.132Troubleshooting the video subsystemp.132Troubleshooting a USB devicep.132Troubleshooting iDRAC Direct (USB XML configuration)p.133Troubleshooting iDRAC Direct (laptop connection)p.134Troubleshooting a serial I/O devicep.134Troubleshooting a NICp.134Troubleshooting a wet systemp.135Troubleshooting a damaged systemp.136Troubleshooting the system batteryp.136Troubleshooting power supply unitsp.137Power source problemsp.137Power supply unit problemsp.137Troubleshooting cooling problemsp.138Troubleshooting cooling fansp.138Troubleshooting system memoryp.139Troubleshooting an SD cardp.140Troubleshooting a hard drivep.140Troubleshooting a storage controllerp.141Troubleshooting expansion cardsp.142Troubleshooting processorsp.142System messagesp.143Warning messagesp.143Diagnostic messagesp.143Alert messagesp.143Using system diagnosticsp.144Dell Embedded System Diagnosticsp.144When to use the Embedded System Diagnosticsp.144Running the Embedded System Diagnostics from Boot Managerp.144Running the Embedded System Diagnostics from the Dell Lifecycle Controllerp.144System diagnostic controlsp.145Jumpers and connectorsp.146System board jumper settingsp.146System board connectorsp.147Disabling a forgotten passwordp.149Technical specificationsp.150Getting helpp.156Contacting Dellp.156Locating your system Service Tagp.156Documentation feedbackp.156Quick Resource Locatorp.156
Page 8 of the Dell XC730xd user manual — Front panel features and indicators
Page 8 · click to enlarge
Page 8

1 About your system

The Dell XC730xd system is web-scale converged appliance based on the Dell PowerEdge R730xd that supports two Intel Xeon E5-2600 v3 processors, up to 24 DIMMs, and 24 hard drives/SSDs.

Supported configuration

Up to twelve 3.5 inch hard drives.

Twenty four hard-drive systems

Up to twenty-four 2.5 inch hard drives.

Front panel features and indicators

Dell XC730xd — Front panel features and indicators diagram (page 8)
Fig. 1 · Front panel features and indicators

Figure 1. Front panel features and indicators (2.5 inch hard drive/SSD chassis)

Systems Configurations · Twelve hard-drive systems

Page 9 of the Dell XC730xd user manual — About your system
Page 9 · click to enlarge
Page 9
Dell XC730xd — About your system diagram (page 9)
Fig. 2 · About your system

Figure 2. Front panel features and indicators (3.5 inch hard drive chassis)

ItemIndicator, Button, or ConnectorIconDescription 1 Diagnostic indicators The diagnostic indicators light up to display error status. For more information, see Diagnostic indicators. 2 System identification You can use the identification buttons on the front button — and back panels to locate a particular system within a rack. When one of these buttons is pressed, the system status indicator on the back flashes until one of the buttons is pressed again. Press to toggle the system ID on and off. If the system stops functioning during POST, press and hold the system ID button for more than five seconds to enter the BIOS progress mode. To reset iDRAC (if not disabled by entering iDRAC Setup mode by pressing ) press and hold the button for more than 15 seconds. 3 Power-on indicator, The power-on indicator lights when the system Power button power is on. The Power button controls the power supply output to the system. NOTE: On the Advanced Configuration and Power Interface (ACPI)-compliant operating systems (OSs), turning off the system by using the power button causes the system to perform a graceful shutdown before power to the system is disconnected. 4 NMI button Use the Non-Maskable Interrupt (NMI) button to troubleshoot software and device driver errors while running certain OSs. Press the NMI button using the end of a paper clip
Page 10 of the Dell XC730xd user manual — Diagnostic indicators
Page 10 · click to enlarge
Page 10
ItemIndicator, Button, or ConnectorIconDescription Use the NMI button only if directed by qualified support personnel or by the OS's documentation . 5 Information tag A slide-out label panel, which allows you to record system information such as Service Tag, NIC, MAC address. 6 Hard drives 2.5 inch hard Up to twenty four 2.5 inch drive/SSD hot-swappable hard drives. systems 3.5 inch hard Up to twelve 3.5 inch hotdrive systems swappable hard drives. 7 USB management port/ Allows you to connect USBdevices to the system iDRAC Direct or provides access to the iDRAC Direct features.For more information, see the Integrated Dell Remote Access ControllerUser’s Guide at dell.com/ esmmanuals. The USB management portis USB 2.0-compliant. 8 iDRAC Direct LED The indicator lights up to display error status. indicator 9 Video connector Enables you to connect a display to the system.

Diagnostic indicators

The diagnostic indicators on the system front panel display error status during system startup.

Table 1. Diagnostic indicators

IconDescriptionConditionCorrective action Health If the system is on, and in None required. indicator good health, the indicator lights solid blue. The indicator blinks amber if See the System Event Log or system the system is on or in messages for the specific issue. For more standby, and if any error information on error messages, see the Dell exists (for example, a failed Event and Error Messages Reference Guide fan or hard drive). at dell.com/esmmanuals.
Page 11 of the Dell XC730xd user manual — Diagnostic indicators
Page 11 · click to enlarge
Page 11
IconDescriptionConditionCorrective action Invalid memory configurations can cause the system to halt at startup without any video output. See Getting help. Hard drive The indicator blinks amber if See the System Event Log to determine the indicator a Hard drive experiences an Hard drive that has an error. Run the error. appropriate Online Diagnostics test. Restart system and run embedded diagnostics (ePSA). Electrical The indicator blinks amber if See the System Event Log or system indicator the system experiences an messages for the specific issue. If it is due electrical error (for example, to a problem with the power supply, check voltage out of range, or a the LED on the power supply. Re-seat the failed power supply or power supply by removing and reinstalling voltage regulator). it. If the problem persists, see Getting help. Temperatur The indicator blinks amber if Ensure that none of the following e indicator the system experiences a conditions exist: thermal error (for example, a • A cooling fan is removed or has failed. temperature out of range or • System cover, cooling shroud, EMI filler fan failure). panel, memory-module blank, or backfiller bracket is removed. • Ambient temperature is too high. • External airflow is obstructed. See Getting help. Memory The indicator blinks amber if See the system event log or system indicator a memory error occurs. messages for the location of the failed memory. Reinstall the memory device. If the problem persists, see Getting help. PCIe The indicator blinks amber if Restart the system. Update any required indicator a PCIe card experiences an drivers for the PCIe card. Re-install the error. card. If the problem persists, see Getting help. NOTE: For more information on supported PCIe cards, see Expansion card installation guidelines.
Page 12 of the Dell XC730xd user manual — Hard drive indicator codes
Page 12 · click to enlarge
Page 12

Hard drive indicator codes

Dell XC730xd — Hard drive indicator codes diagram (page 12)
Fig. 3 · Hard drive indicator codes

Figure 3. Hard drive indicators

1. Hard drive activity indicator 2. Hard drive status indicator
3. Hard drive
Dell XC730xd — Hard drive indicator codes diagram (page 12)
Fig. 4 · Hard drive indicator codes

Figure 4. HDD indicators on the hard-drive tray backplane

1. Hard drive activity indicator 2. Hard drive status indicator
3. Hard drive backplane on hard-drive tray
Page 13 of the Dell XC730xd user manual — iDRAC Direct LED indicator codes
Page 13 · click to enlarge
Page 13

Table 2.

Drive-status indicator pattern Condition

Blinks green two times per second Identifying drive or preparing for removal. HDD or SSD location is enabled or one of more HDDs or SSDs is in the failed state on the Nutanix Web GUI.

Off Drive ready for insertion or removal.

Blinks green, amber, and turns off Predicted drive failure

Blinks amber four times per second Drive failed

Blinks green slowly Drive rebuilding

Steady green Drive online

Blinks green three seconds, amber three seconds, and turns off six seconds

iDRAC Direct LED indicator codes

Dell XC730xd — iDRAC Direct LED indicator codes diagram (page 13)
Fig. 5 · iDRAC Direct LED indicator codes

Figure 5. iDRAC Direct LED indicator

1. iDRAC Direct status indicator

The table below displays iDRAC Direct activity when configuring iDRAC Direct by using the management port (USB XML Import).

Rebuild aborted

Page 14 of the Dell XC730xd user manual — Back-panel features and indicators
Page 14 · click to enlarge
Page 14

Table 3. iDRAC Direct by using the management port (USB XML Import).

Convention iDRAC Direct LED indicator pattern

A Green Lights green for a minimum of 2 seconds at the beginning and end of a file transfer.

B Flashing green Indicates file transfer or any operation tasks.

C Green and turns off

Indicates that the file transfer is complete.

D Not lit Indicates that the USB is ready to be removed or that a task is complete.

The table below displays iDRAC Direct activity when configuring iDRAC Direct using your laptop and cable (Laptop Connect).

Table 4. iDRAC Direct using your laptop and cable (Laptop Connect).

iDRAC Direct LED indicator pattern

Solid green for two seconds

Indicates that the laptop is connected.

Flashing green (on for two seconds and off for two seconds)

Indicates that the laptop connected is recognized.

Turns off Indicates that the laptop is unplugged.

Back-panel features and indicators

Item Indicator, button, or connector

1 System identification button

You can use the identification buttons on the front to locate a particular system within a rack. When one of these buttons is pressed, the system status indicator on the back flashes until one of the buttons is pressed again.

Press to toggle the system ID on and off. If the system stops responding during POST, press and hold the system ID button for more than five seconds to enter the BIOS progress mode.

Condition · Condition · Icon Description

Page 15 of the Dell XC730xd user manual — Back-panel features and indicators
Page 15 · click to enlarge
Page 15

Item Indicator, button, or connector

To reset iDRAC (if not disabled in F2 iDRAC setup) press and hold the button for more than 15 seconds.

2 System identification connector

Connects the optional system status indicator assembly through the optional cable management arm.

3 iDRAC8 Enterprise port

Dedicated management port for iDRAC8.

4 Half-height PCIe expansion-card slot (3)

Allows you to connect up to three half- height PCI Express expansion cards.

Allows you to connect a serial device to the system.

Allows you to connect a VGA display to the system.

7 USB connector (2)

Allows you to connect USB devices to the system. The ports are USB 3.0- compliant.

8 Full-height PCIe expansion-card slot (3)

Allows you to connect up to three full- height PCI Express expansion cards. These are reserved for Dell PERC H310 and LSI 9207-8i.

9 Ethernet connector (4)

Four integrated 10/100/1000 Mbps NIC connectors

Four integrated connectors that include:

  • Two 10/100/1000 Mbps NIC connectors
  • Two 100 Mbps/1 Gbps/10 Gbps SFP +/10 GbE T connectors

10 Power supply unit (PSU1) AC 495 W, 750 W, or 1100 W

11 Power supply unit (PSU2)

DC 495 W, 750 W, or 1100 W

12 vFlash media card slot

Allows you to insert a vFlash media card.

13 Two HDD blanks

Show 4 more labels / short text on this page
Icon Description · 5 Serial connector · 6 Video connector · or
Page 16 of the Dell XC730xd user manual — Power indicator codes
Page 16 · click to enlarge
Page 16

NIC indicator codes

Dell XC730xd — NIC indicator codes diagram (page 16)
Fig. 6 · NIC indicator codes

Figure 6. NIC indicators

1. link indicator 2. activity indicator

A Link and activity indicators are off The NIC is not connected to the network.

B Link indicator is green The NIC is connected to a valid network at its maximum port speed (1 Gbps or 10 Gbps).

C Link indicator is amber The NIC is connected to a valid network at less than its maximum port speed.

D Activity indicator is blinking green Network data is being sent or

received.

Power indicator codes

Each AC power supply unit (PSU) has an illuminated translucent handle and each DC power supply unit (when available) has an LED that serves as an indicator to show whether power is present or a power fault has occurred.

Indicator Indicator code

Page 17 of the Dell XC730xd user manual — NIC indicator codes
Page 17 · click to enlarge
Page 17
Dell XC730xd — NIC indicator codes diagram (page 17)
Fig. 7 · NIC indicator codes

Figure 7. AC power supply unit status indicator

1. AC power supply unit status indicator/handle

Table 5. AC Power indicator

Convention Power indicator pattern

A Green The handle indicator lights green indicating that a valid power source is connected to the power supply unit and that the power supply unit is operational.

B Flashing green When updating the firmware of the power supply unit, the power supply unit handle flashes green.

C Flashing green and turns off

When hot-adding a power supply unit (PSU), the power supply unit handle flashes green five times at 4 Hz rate and turns off. This indicates that the power supply unit is mismatched with the other power supply unit (in terms of efficiency, feature set, health status, and supported voltage). Replace the power supply unit that has the flashing indicator with a power supply unit that matches the capacity of the other installed power supply unit.

D Flashing amber Indicates a problem with the power supply unit.

Condition

Page 18 of the Dell XC730xd user manual — NIC indicator codes
Page 18 · click to enlarge
Page 18

Convention Power indicator pattern

E Not lit Power is not connected.

Dell XC730xd — NIC indicator codes diagram (page 18)
Fig. 8 · NIC indicator codes

Figure 8. DC power supply unit status indicator

1. DC power supply unit status indicator

Condition

Page 19 of the Dell XC730xd user manual — Documentation matrix
Page 19 · click to enlarge
Page 19

Table 6. DC Power indicator

Convention Power indicator pattern

A Green The handle/LED indicator lights green indicating that a valid power source is connected to the power supply unit and that the power supply unit is operational.

B Flashing green When hot-adding a power supply unit, power supply unit LED flashes green. This indicates that the power supply unit is mismatched with the other power supply unit (in terms of efficiency, feature set, health status, and supported voltage). Replace the power supply unit that has the flashing indicator with a power supply unit that matches the capacity of the other installed power supply unit.

C Flashing amber Indicates a problem with the power supply unit.

D Not lit Power is not connected.

Documentation matrix

The documentation matrix provides information about the documents you use to configure and deploy the Dell web-scale converged appliance solution.

Make sure that you read through any media that ships with your system that provides documentation and tools for configuring and managing your system, including those pertaining to the OS, system management software, system updates, and system components that you purchased with your system.

Condition

Page 20 of the Dell XC730xd user manual — Nutanix documentation
Page 20 · click to enlarge
Page 20

For the full name of an abbreviation or acronym used in this document, see the Glossary at dell.com/ support/home.

The following tables list the documents provided by Dell and Nutanix.

Dell documentation

Dell documentation is either included with your shipment or available at the Dell website at dell.com/ xcseriesmanuals.

Dell documentation for:

  • Dell iDRAC is available at <a href="http://dell.com/esmmanuals" rel="nofollow noopener" target="_blank">dell.com/esmmanuals</a> .
  • Dell OpenManage Essentials is available at <a href="http://dell.com/openmanagemanuals" rel="nofollow noopener" target="_blank">dell.com/openmanagemanuals</a> .

To access Dell documentation:

1. On the Dell Support page, scroll down to General Support , and then click Servers, Storage & Networking .
2. Click Engineered Solutions and select the documentation you require.

Table 7. Dell reference documentation for the Dell XC730xd Web-scale Converged Appliance

To learn about… Refer to…

Setup instructions of your Dell XC730xd, including the technical specifications

Hardware details of your Dell XC730xd Owner’s Manual

How to install your Dell XC730xd in a rack Dell Rack Install Guide

How to deploy and set up this solution Solutions Guide

Setting up and using Dell iDRAC 8 Dell iDRAC 8 Quick Start Guide

Using OpenManage Essentials to monitor, perform updates, view hardware, and view inventory on your system

Dell OpenManage Essentials User’s Guide

Nutanix documentation

Most Nutanix documentation is available at https://portal.nutanix.com/#/page/docs on the Nutanix Documents page. However, two documents are available behind the Nutanix document portal. Nutanix documentation is listed by version, category, and type. Make sure that you select the appropriate version of documentation for this release, which is 4.0 or later. Or refer to the Nutanix OS to find corresponding documentation support.

To access most Nutanix documentation:

Getting Started Guide

Page 21 of the Dell XC730xd user manual — Quick Resource Locator
Page 21 · click to enlarge
Page 21
2. Select the documentation you require from the list specified in Table 10.

To access the NOS Advanced Administration Guide and Advanced Setup Guide:

2. Log in to your portal and select Documentation .
3. On the Nutanix Documents page, select the documentation you require.

Table 8. Nutanix reference documentation

To learn about… Refer to…

Setup instructions for your solution. Setup Guide

Setup instructions for environments with special requirements and restrictions

Instructions and reference for administering the Nutanix Operation System (NOS) outside the Nutanix Prism UI (such as cluster start/stop, manual upgrade, changing passwords, reconfiguring IP addresses, and troubleshooting tools).

NOS Advanced Administration Guide

Comprehensive instructions and references for the Nutanix UI, including overview information.

Managing VMware ESXi hosts that run NOS, including VMware vCenter requirements.

Managing Hyper-V hosts that run NOS. Hyper-V Administration Guide

Comprehensive references for the Nutanix REST API.

Comprehensive references for Controller Virtual Machine (CVM) utilities, nCLI commands, and Nutanix PowerShell cmdlets.

Software instructions for hardware components that are not functioning.

Quick Resource Locator

Use the Quick Resource Locator (QRL) to get immediate access to system information and how-to videos. This can be done by visiting dell.com/QRL or by using your smartphone or tablet and a model specific Quick Resource (QR) code located on your Dell system. To try out the QR code, scan the following image.

Show 6 more labels / short text on this page
Advanced Setup Guide · Web Console Guide · vSphere Administration Guide · API Reference · Command Reference · Hardware Replacement Documentation
Page 22 of the Dell XC730xd user manual — Quick Resource Locator
Page 22 · click to enlarge
Page 22
Dell XC730xd — Quick Resource Locator diagram (page 22)
Fig. 9 · Quick Resource Locator

Figure 9. Quick Resource Locator

Page 23 of the Dell XC730xd user manual — Logging in to iDRAC
Page 23 · click to enlarge
Page 23

2 Performing initial system configuration

After you receive your system, you must set up your system, install the operating system if it is not pre- installed, and set up and configure the system iDRAC IP address.

Setting up your system

1. Unpack the server.
2. Install the server into the rack. For more information on installing the server into the rack, see your system Rack Installation Placemat at dell.com/xcseriesmanuals.
3. Connect the peripherals to the system.
4. Connect the system to its electrical outlet.
5. Turn the system on by pressing the Power button or using iDRAC.
6. Turn on the attached peripherals.

Methods of setting up and configuring the iDRAC IP address

You can set up the Integrated Dell Remote Access Controller (iDRAC) IP address by using one of the following interfaces:

  • iDRAC Settings utility.
  • Lifecycle Controller.
  • Dell Deployment Toolkit.
  • Server LCD panel.

You can configure iDRAC IP using:

1. iDRAC Web Interface.

For more information on setting up and configuring iDRAC, see the Integrated Dell Remote Access Controller User's Guide at dell.com/esmmanuals

2. Remote Access Controller ADMin (RACADM).

For more information, see the RACADM Command Line Interface Reference Guide and the Integrated Dell Remote Access Controller User's Guide.

3. Remote Services that includes Web Services Management (WS-Man). For more information, see the Lifecycle Controller Remote Services Quick Start Guide .

Logging in to iDRAC

You can log in to iDRAC as an iDRAC local user, a Microsoft Active Directory user, or a Lightweight Directory Access Protocol (LDAP) user. You can also log in by using Single Sign-On or a Smart Card. The

Page 24 of the Dell XC730xd user manual — Downloading and installing drivers and firmware
Page 24 · click to enlarge
Page 24

default user name is root and password is calvin. For more information on logging in to iDRAC and iDRAC licenses, see the Integrated Dell Remote Access Controller User's Guide at dell.com/esmmanuals

You can also access iDRAC using RACADM. For more information, see the RACADM Command Line Interface Reference Guide and the Integrated Dell Remote Access Controller User's Guide available at dell.com/esmmanuals

Installing the operating system

If the server is shipped without an operating system, install the supported operating system on the server by using one of the following methods:

  • Dell Systems Management Tools and Documentation media. See the operating system documentation at <a href="http://dell.com/operatingsystemmanuals" rel="nofollow noopener" target="_blank">dell.com/operatingsystemmanuals</a> .
  • Dell Lifecycle Controller. See the Lifecycle Controller documentation at <a href="http://dell.com/esmmanuals" rel="nofollow noopener" target="_blank">dell.com/esmmanuals</a> .
  • Dell OpenManage Deployment Toolkit. See the OpenManage documentation at <a href="http://dell.com/" rel="nofollow noopener" target="_blank">dell.com/</a> openmanagemanuals .

For information on the list of operating systems supported on your system, see the operating systems support matrix at dell.com/ossupport

Remote management

To perform out-of-band systems management using iDRAC, you must configure iDRAC for remote accessibility, set up the management station and managed system, and configure the supported Web browsers. For more information, see the Integrated Dell Remote Access Controller User’s Guide at dell.com/esmmanuals

You can also remotely monitor and manage the server by using the Dell OpenManage Server Administrator software and OpenManage Essentials systems management console. For more information, see dell.com/openmanagemanuals

Downloading and installing drivers and firmware

Dell recommends that you download and install the latest BIOS, drivers, and systems management firmware on your system.

Ensure that you clear the web browser cache.

Steps 1. Go to Support.Dell.com.

2. Under Support in the Customized support section type your Service Tag into the Enter your Service Tag or Express Service code box.
3. Click Drivers & downloads .

The drivers that are applicable to your selection are displayed.

4. Download the drivers you require to a diskette drive, USB drive, CD, or DVD.
Page 25 of the Dell XC730xd user manual — Navigation keys
Page 25 · click to enlarge
Page 25

3 Pre-operating system management applications

The pre-operating system management applications for your system helps you manage different settings and features of your system without booting to the operating system.

Your system has the following pre-operating system management applications:

  • System Setup
  • Boot Manager
  • Dell Lifecycle Controller

Dell Lifecycle Controller allows you to perform useful tasks such as configuring BIOS and hardware settings, deploying operating system, updating drivers, and saving hardware profiles. For more information about Dell Lifecycle Controller, see the documentation at dell.com/esmmanuals

Navigation keys

The navigation keys can help you access the pre-operating system management applications.

Table 9. Navigation keys

Page Up Moves to the previous screen.

Page Down Moves to the next screen.

Up arrow Moves to the previous field.

Moves to the next field.

Enter Enables you to type a value in the selected field (if applicable) or follow the link in the field.

Spacebar Expands or collapses a drop-down list, if applicable.

Tab Moves to the next focus area.

Esc Moves to the previous page until you view the main screen. Pressing Esc in the main screen exits System BIOS/iDRAC Settings/Device Settings/Service Tag Settings and proceeds with system boot.

F1 Displays the System Setup help.

F2 Enables you to enter System Setup

Key Description · Down arrow

Page 26 of the Dell XC730xd user manual — Entering System Setup
Page 26 · click to enlarge
Page 26

F10 Enables you to enter Lifecycle Controller

F11 Enables you to enter Boot Manager

F12 Enables you to enter PXE boot

About System Setup

Using System Setup, you can configure the BIOS settings, iDRAC settings, and device settings of your system.

You can access System Setup in two ways:

  • Standard Graphical Browser — This is enabled by default.
  • Text Browser — This is enabled using Console Redirection.

To enable Console Redirection:

  • On the System Setup page, click System BIOS .
  • On the Serial Communications page, click Serial Communication , and then select On with Console Redirection .

From System Setup, you can:

  • Change the NVRAM settings after you add or remove hardware
  • View the system hardware configuration
  • Enable or disable integrated devices
  • Set performance and power management thresholds
  • Manage system security

Entering System Setup

1. Turn on or restart your system.
2. Press F2 immediately after you see the following message: = System Setup

If your operating system begins to load before you press F2, allow the system to finish booting, and then restart your system and try again.

Key Description

Page 27 of the Dell XC730xd user manual — Editing system BIOS screen settings
Page 27 · click to enlarge
Page 27

System Setup Main Menu

Table 10. System setup main menu

System BIOS Enables you to configure BIOS settings.

iDRAC Settings Enables you to configure iDRAC settings.

The iDRAC Settings utility is an interface to set up and configure the iDRAC parameters by using UEFI. You can enable or disable various iDRAC parameters by using the iDRAC Settings utility. For more information about this utility, see the Integrated Dell Remote Access Controller User’s Guide at dell.com/esmmanuals

Device Settings Enables you to configure device settings.

Editing system BIOS screen settings

You can use the System BIOS screen to view the BIOS settings. You can also edit some of the settings such as Boot Order, System Password, Setup Password, and enable or disable USB ports.

Go to System Setup Main Menu, and then click System BIOS.

The System BIOS screen is displayed.

System BIOS screen settings

The System BIOS screen details are explained below.

Table 11. System BIOS

System Information Displays information about the system such as the system model name, BIOS version and Service Tag.

Memory Settings Displays information and options related to the installed memory.

Processor Settings Displays information and options related to the processor such as speed, cache size, and so on.

SATA Settings Displays options to enable or disable the integrated SATA controller and ports.

Boot Settings Displays options to specify the boot mode (BIOS or UEFI). Enables you to modify UEFI and BIOS boot settings.

Network Settings Displays options to change the network settings.

Integrated Devices Displays options to enable or disable integrated device controllers and ports, and to specify related features and options.

Serial Communication Displays options to enable or disable the serial ports and specify related features and options.

System Profile Settings Displays options to change the processor power management settings, memory frequency, and so on.

System Security Displays options to configure the system security settings like, system password, setup password, Trusted Platform Module (TPM) security, and

Option Description · Menu Item Description

Page 28 of the Dell XC730xd user manual — Editing memory settings
Page 28 · click to enlarge
Page 28

so on. It also enables or disables support for the power and NMI buttons on the system.

Miscellaneous Settings Displays options to change the system date, time, and so on.

Editing system information

You can use the System Information screen to view system properties such as Service Tag, system model, and the BIOS version.

1. Go to System Setup Main Menu , and then click System BIOS .
2. On System BIOS , click System Information .

The System Information screen is displayed.

System information screen settings

The System Information screen details are explained as follows:

Table 12. System information

System Model Name Displays the system model name.

System BIOS Version Displays the BIOS version installed on the system.

System Management Engine Version

Displays the current revision of the Management Engine firmware.

System Service Tag Displays the system Service Tag.

System Manufacturer Displays the name of the system manufacturer.

System Manufacturer Contact Information

Displays the contact information of the system manufacturer.

System CPLD Version Displays the current revision of the system CPLD firmware.

UEFI Compliance Version Displays the system firmware UEFI compliance level.

Editing memory settings

You can use the Memory Settings screen to view all the memory settings. You can also enable or disable some memory configurations such as system memory testing and node interleaving.

1. Go to System Setup Main Menu , and then click System BIOS .
2. On System BIOS , click Memory Settings .

The Memory Settings screen displays..

The Memory Settings screen details are explained as follows:

Menu Item Description · Menu Item Description · Memory screen settings

Page 29 of the Dell XC730xd user manual — Editing processor settings
Page 29 · click to enlarge
Page 29

Table 13. Memory settings

System Memory Size Displays the amount of memory installed in the system.

System Memory Type Displays the type of memory installed in the system.

System Memory Speed Displays the system memory speed.

System Memory Voltage Displays the system memory voltage.

Video Memory Displays the amount of video memory.

System Memory Testing Specifies whether system memory tests are run during system boot. Options are Enabled and Disabled. By default, the System Memory Testing option is set to Disabled.

Memory Operating Mode Specifies the memory operating mode. The options available are Optimizer Mode, Advanced ECC Mode, Mirror Mode, Spare Mode, Spare with Advanced ECC Mode, and Dell Fault Resilient Mode. By default, the Memory Operating Mode option is set to Optimizer Mode.

Node Interleaving Specifies if Non-Uniform Memory architecture (NUMA) is supported. If this field is Enabled, memory interleaving is supported if a symmetric memory configuration is installed. If Disabled, the system supports NUMA (asymmetric) memory configurations. By default, Node Interleaving option is set to Disabled.

Snoop Mode Specifies the Snoop Mode options. Snoop Mode options available are Home Snoop, Early Snoop, Cluster on Die. By default, the Snoop Mode option is set to Early Snoop. The field is only available when Node Interleaving is Disabled.

Editing processor settings

You can use the Processor Settings screen to view the processor settings. You can also enable virtualization technology, hardware prefetcher, and logical processor idling.

1. Go to System Setup Main Menu , and then click System BIOS .
2. On System BIOS , click Processor Settings .

The Processor Settings screen displays.

The Processor Settings screen details are explained as follows:

Menu Item Description · Processor settings screen

Page 30 of the Dell XC730xd user manual — Editing processor settings
Page 30 · click to enlarge
Page 30

Table 14. Processor settings

Logical Processor Enables or disables the logical processors and displays the number of logical processors. If the Logical Processor option is set to Enabled, the BIOS displays all the logical processors. If this option is set to Disabled, the BIOS only displays one logical processor per core. By default, the Logical Processor option is set to Enabled.

Alternate RTID (Requestor Transaction ID) Setting

Enables you to allocate more RTIDs to the remote socket, thereby increasing cache performance between the sockets or easing work in normal mode for NUMA. By default, the Alternate RTID (Requestor Transaction ID) Setting is set to Disabled.

Virtualization Technology Enables or disables the additional hardware capabilities provided for virtualization. By default, the Virtualization Technology option is set to Enabled.

Address Translation Service (ATS)

Defines the Address Translation Cache (ATC) for devices to cache the DMA transactions. This field provides an interface to a chipset's Address Translation and Protection Table to translate DMA addresses to host addresses. By default, the option is set to Enabled.

Adjacent Cache Line Prefetch

Optimizes the system for applications that require high usage of sequential memory access. By default, the Adjacent Cache Line Prefetch option is set to Enabled. You can disable this option for applications that require high usage of random memory access.

Hardware Prefetcher Enables or disables the hardware prefetcher. By default, the Hardware Prefetcher option is set to Enabled.

DCU Streamer Prefetcher Allows you to enable or disable the Data Cache Unit (DCU) streamer prefetcher. By default, the DCU Streamer Prefetcher option is set to Enabled.

DCU IP Prefetcher Enables or disables the Data Cache Unit (DCU) IP prefetcher. By default, the DCU IP Prefetcher option is set to Enabled.

Execute Disable Enables or disables the execute disable memory protection technology. By default, the Execute Disable option is set to Enabled.

Logical Processor Idling Enables or disables the operating system capability to put logical processors in the idling state in order to reduce power consumption. By default, the option is set to Disabled.

Configurable TDP Allows reconfiguration of Thermal Design Power (TDP) to lower levels. TDP refers to the maximum amount of power the cooling system is required to dissipate.

X2Apic Mode Enables or disables the X2Apic mode.

Controls the turbo engagement. Enable this option only when System Profile is set to Performance.

Number of Cores per Processor

Controls the number of enabled cores in each processor. By default, the Number of Cores per Processor option is set to All.

Processor 64-bit Support Specifies if the processor(s) support 64-bit extensions.

Menu Item Description · Dell Controlled Turbo

Page 31 of the Dell XC730xd user manual — Editing SATA Settings
Page 31 · click to enlarge
Page 31

Processor Core Speed Displays the maximum core frequency of the processor.

  • Family-Model-Stepping : Displays the family, model and stepping of the processor as defined by Intel.
  • Brand : Displays the brand name reported by the processor.
  • Level 2 Cache : Displays the total L2 cache.
  • Level 3 Cache : Displays the total L3 cache.
  • Number of Cores : Displays the number of cores per processor.

Editing SATA Settings

You can use the SATA Settings screen to view the SATA settings of SATA devices and enable RAID on your system.

1. Go to System Setup Main Menu , and then click System BIOS .
2. On System BIOS , click SATA Settings .

The SATA Settings screen displays.

The SATA Settings screen details are explained below.

Table 15. SATA settings

Embedded SATA Enables the embedded SATA to be set to Off, ATA, AHCI, or RAID modes. By default, the Embedded SATA option is set to AHCI.

Security Freeze Lock Sends Security Freeze Lock command to the Embedded SATA drives during POST. This option is applicable only to ATA and AHCI mode.

Write Cache Enables or disables the command for Embedded SATA drives during POST.

Port A Sets the drive type of the selected device. For Embedded SATA settings in ATA mode, set this field to Auto to enable BIOS support. Set it to OFF to turn off BIOS support. For AHCI mode or RAID mode, BIOS always enables support.

Model: Displays the drive model of the selected device.

Drive Type: Displays the type of drive attached to the SATA port.

Capacity: Displays the total capacity of the hard drive. The field is undefined for removable media devices such as optical drives.

Port B Sets the drive type of the selected device. For Embedded SATA settings in ATA mode, set this field to Auto to enable BIOS support. Set it to OFF to turn off BIOS support.

Show 4 more labels / short text on this page
Menu Item Description · Processor 1 · SATA settings screen · Menu Item Description
Page 32 of the Dell XC730xd user manual — Editing SATA Settings
Page 32 · click to enlarge
Page 32

For AHCI mode or RAID mode, BIOS always enables support.

Model: Displays the drive model of the selected device.

Drive Type: Displays the type of drive attached to the SATA port.

Capacity: Displays the total capacity of the hard drive. The field is undefined for removable media devices such as optical drives.

Port C Sets the drive type of the selected device. For Embedded SATA settings in ATA mode, set this field to Auto to enable BIOS support. Set it to OFF to turn off BIOS support. For AHCI mode or RAID mode, BIOS always enables support.

Model: Displays the drive model of the selected device.

Drive Type: Displays the type of drive attached to the SATA port.

Capacity: Displays the total capacity of the hard drive. The field is undefined for removable media devices such as optical drives.

Port D Sets the drive type of the selected device. For Embedded SATA settings in ATA mode, set this field to Auto to enable BIOS support. Set it to OFF to turn off BIOS support. For AHCI mode or RAID mode, BIOS always enables support.

Model: Displays the drive model of the selected device.

Drive Type: Displays the type of drive attached to the SATA port.

Capacity: Displays the total capacity of the hard drive. The field is undefined for removable media devices such as optical drives.

Port E Sets the drive type of the selected device. For Embedded SATA settings in ATA mode, set this field to Auto to enable BIOS support. Set it to OFF to turn off BIOS support. For AHCI mode or RAID mode, BIOS always enables support.

Model: Displays the drive model of the selected device.

Drive Type: Displays the type of drive attached to the SATA port.

Capacity: Displays the total capacity of the hard drive. The field is undefined for removable media devices such as optical drives.

Port F Sets the drive type of the selected device. For Embedded SATA settings in ATA mode, set this field to Auto to enable BIOS support. Set it to OFF to turn off BIOS support. For AHCI mode or RAID mode, BIOS always enables support.

Model: Displays the drive model of the selected device.

Drive Type: Displays the type of drive attached to the SATA port.

Menu Item Description

Page 33 of the Dell XC730xd user manual — Editing SATA Settings
Page 33 · click to enlarge
Page 33

Capacity: Displays the total capacity of the hard drive. The field is undefined for removable media devices such as optical drives.

Port G Sets the drive type of the selected device. For Embedded SATA settings in ATA mode, set this field to Auto to enable BIOS support. Set it to OFF to turn off BIOS support. For AHCI mode or RAID mode, BIOS always enables support.

Model: Displays the drive model of the selected device.

Drive Type: Displays the type of drive attached to the SATA port.

Capacity: Displays the total capacity of the hard drive. The field is undefined for removable media devices such as optical drives.

Port H Sets the drive type of the selected device. For Embedded SATA settings in ATA mode, set this field to Auto to enable BIOS support. Set it to OFF to turn off BIOS support. For AHCI mode or RAID mode, BIOS always enables support.

Model: Displays the drive model of the selected device.

Drive Type: Displays the type of drive attached to the SATA port.

Capacity: Displays the total capacity of the hard drive. The field is undefined for removable media devices such as optical drives.

Port I Sets the drive type of the selected device. For Embedded SATA settings in ATA mode, set this field to Auto to enable BIOS support. Set it to OFF to turn off BIOS support. For AHCI mode or RAID mode, BIOS always enables support.

Model: Displays the drive model of the selected device.

Drive Type: Displays the type of drive attached to the SATA port.

Capacity: Displays the total capacity of the hard drive. The field is undefined for removable media devices such as optical drives.

Port J Sets the drive type of the selected device. For Embedded SATA settings in ATA mode, set this field to Auto to enable BIOS support. Set it to OFF to turn off BIOS support. For AHCI mode or RAID mode, BIOS always enables support.

Model: Displays the drive model of the selected device.

Drive Type: Displays the type of drive attached to the SATA port.

Capacity: Displays the total capacity of the hard drive. The field is undefined for removable media devices such as optical drives.

Menu Item Description

Page 34 of the Dell XC730xd user manual — Editing network settings
Page 34 · click to enlarge
Page 34

Editing boot settings screen

You can use the Boot Settings screen to set the Boot mode to either BIOS or UEFI. It also allows you to specify the boot order.

1. Go to System Setup Main Menu , and then click System BIOS .
2. On System BIOS , click Boot Settings .

The Boot Settings screen displays.

The Boot Settings screen details are explained as follows:

Table 16. Boot settings

Boot Mode Enables you to set the boot mode of the system.

If the operating system supports UEFI, you can set this option to UEFI. Setting this field to BIOS allows compatibility with non-UEFI operating systems. By default, the Boot Mode option is set to BIOS.

Boot Sequence Retry Enables or disables the Boot Sequence Retry feature. If this field is enabled and the system fails to boot, the system reattempts the boot sequence after 30 seconds. By default, the Boot Sequence Retry option is set to Enabled.

Hard-Disk Failover Specifies which devices in the Hard-Disk Drive Sequence are attempted in the boot sequence. When the option is Disabled, only the first hard disk device in the list is attempted to boot. When set to Enabled, all hard disk devices are attempted in order, as listed in the Hard-Disk Drive Sequence. This option is not enabled for UEFI Boot Mode.

Boot Option Settings Configures the boot sequence and the boot devices.

Editing network settings

You can use the Network Settings screen to modify Preboot eXecution Environment (PXE) device settings. Network Settings are only available in UEFI boot mode. BIOS does not control network settings in the BIOS boot mode. For BIOS boot mode, the network settings are handled by the network controllers option ROM.

1. Go to System Setup Main Menu , and then click System BIOS .
2. On System BIOS , click Network Settings .

Boot Settings · Menu Item Description

Page 35 of the Dell XC730xd user manual — Editing integrated devices details
Page 35 · click to enlarge
Page 35

The Network Settings screen displays.

The Network Settings screen details are explained as follows:

Table 17. Network settings

PXE Device n (n = 1 to 4) Enables or disables the device. When enabled, a UEFI boot option is created for the device.

PXE Device n Settings (n = 1 to 4)

Allows you to control the configuration of the PXE device.

Editing integrated devices details

You can use the Integrated Devices screen to view and configure the settings of all integrated devices including the video controller, integrated RAID controller, and the USB ports.

1. Go to System Setup Main Menu , and then click System BIOS .
2. On System BIOS , click Integrated Devices .

The Integrated Devices screen displays.

Integrated devices screen details

The Integrated Devices screen details are explained below.

Table 18. Integrated devices

USB 3.0 Setting Enables or disables the USB 3.0 support. Enable this option only if your operating system supports USB 3.0. If you disable this option, devices operate at USB 2.0 speed. USB 3.0 is disabled by default.

User Accessible USB Ports

Enables or disables the USB ports. Selecting Only Back Ports On disables the front USB ports, selecting All Ports Off disables all USB ports. The USB keyboard and mouse operates during boot process in certain operating systems. After the boot process is complete, the USB keyboard and mouse do not work if the ports are disabled.

Internal USB Port Enables or disables the internal USB port. By default, the option is set to Enabled.

Enables or disables the integrated RAID controller. By default, the option is set to Enabled.

Integrated Network Card 1

Enables or disables the integrated network card.

Embedded NIC1 and NIC2

Enables or disables the Embedded NIC1 and NIC2 . If set to Disabled, the NIC may still be available for shared network access by the embedded

Show 4 more labels / short text on this page
Network settings screen · Menu Item Description · Menu Item Description · Integrated RAID Controller
Page 36 of the Dell XC730xd user manual — Editing serial communication settings
Page 36 · click to enlarge
Page 36

management controller. The embedded NIC1 and NIC2 option is only available on systems that do not have NDCs. This option is mutually exclusive with the Integrated Network Card 1 option. Configure this function using the NIC management utilities of the system.

I/OAT DMA Engine Enables or disables the I/OAT option. Enable only if the hardware and software support the feature.

Enables or disables the Embedded Video Controller. By default, the embedded video controller is Enabled. Current state of Embedded Video Controller is Enabled. Current State of Embedded Video Controller is a read only field, indicating the current state for the Embedded Video Controller. If the Embedded Video Controller is the only display capability in the system (that is, no add-in graphics card is installed), then the Embedded Video Controller is automatically used as the primary display even if the Embedded Video Controller setting is Disabled.

Current State of Embedded Video Controller

Displays the current state of the Embedded Video Controller. Current State of Embedded Video Controller is a read only field, indicating the current state for the Embedded Video Controller.

SR-IOV Global Enable Enables or disables the BIOS configuration of Single Root I/O Virtualization (SR-IOV) devices. By default, the SR-IOV Global Enable option is set to Disabled.

OS Watchdog Timer If your system stops responding, this OS Watchdog Timer aids in the recovery of your operating system. When this field is set to Enabled, the operating system is allowed to initialize the timer. When the option is set to Disabled (the default), the timer has no effect on the system.

Memory Mapped I/O above 4GB

Enables or disables the support for PCIe devices that require large amounts of memory. By default, the option is set to Enabled.

Slot Disablement Enables or disables the available PCIe slots on your system. The Slot Disablement feature controls the configuration of PCIe cards installed in the specified slot. Slot disablement must be used only when the installed peripheral card is preventing booting into the operating system or causing delays in system startup. If the slot is disabled, both the Option ROM and UEFI driver are disabled.

Editing serial communication settings

You can use the Serial Communication screen to view the properties of the serial communication port.

1. Go to System Setup Main Menu , and then click System BIOS .
2. On System BIOS , click Serial Communication .

The Serial Communication screen is displayed

Serial Communication screen settings

The Serial Communication screen details are explained below.

Menu Item Description · Embedded Video Controller

Page 37 of the Dell XC730xd user manual — Editing system profile
Page 37 · click to enlarge
Page 37

Table 19. Serial communication

Serial Communication Selects serial communication devices (Serial Device 1 and Serial Device 2) in the BIOS. This is where you can select BIOS console redirection and specify the port address. By default, Serial Communication option is set to Auto.

Serial Port Address With Serial Communication, you can set the port address for serial devices. By default, the Serial Port Address option is set to Serial Device 1=COM2, Serial Device 2=COM1

External Serial Connector With the External Serial Connector, you can associate the External Serial Connector to Serial Device 1, Serial Device 2, or the Remote Access Device using this field.

Failsafe Baud Rate Displays the Failsafe baud rate for console redirection. The BIOS attempts to determine the baud rate automatically. This Failsafe baud rate is used only if the attempt fails, and the value must not be changed. By default, the Failsafe Baud Rate option is set to 115200.

Remote Terminal Type Sets the remote console terminal type. By default, the Remote Terminal Type option is set to VT 100/VT 220.

Redirection After Boot Enables or disables the BIOS console redirection when the operating system is loaded. By default, the Redirection After Boot option is set to Enabled.

Editing system profile

You can use the System Profile Settings screen to enable system performance settings such as power management.

1. Go to System Setup Main Menu , and then click System BIOS .
2. On System BIOS , click System Profile Settings .

The System Profile Settings screen is displayed.

Menu Item Description

Page 38 of the Dell XC730xd user manual — Editing system profile
Page 38 · click to enlarge
Page 38

System profile screen settings

The System Profile Settings screen details are explained as follows:

Table 20. System profile settings

System Profile Sets the system profile. If you set the System Profile option to a mode other than Custom, the BIOS automatically sets the rest of the options. You can only change the rest of the options if the mode is set to Custom. By default, the System Profile option is set to Performance Per Watt Optimized (DAPC). DAPC is Dell Active Power Controller.

  • CPU Power Management : Sets the CPU power management. By default, the CPU Power Management option is set to System DBPM (DAPC) . DBPM is Demand-Based Power Management.
  • Memory Frequency : Sets the speed of the system memory. You can select Maximum Performance , Maximum Reliability , or a specific speed.
  • Turbo Boost : Enables or disables the processor to operate in turbo boost mode. By default, the Turbo Boost option is set to Enabled .
  • Energy Efficient Turbo : Enables or disables the Energy Efficient Turbo . Energy Efficient Turbo (EET) is a mode of operation where a processor’s core frequency is adjusted within the turbo range based on workload.
  • C1E : Enables or disables the processor to switch to a minimum performance state when it is idle. By default, the C1E option is set to Enabled .
  • C States : Enables or disables the processor to operate in all available power states. By default, the C States option is set to Enabled .
  • Collaborative CPU Performance Control : Enables or disables the CPU power management. When set to Enabled , the CPU power management is controlled by the OS DBPM and the System DBPM (DAPC). By default, the option is set to Disabled .
  • Memory Patrol Scrub : Sets the memory patrol scrub frequency. By default, the Memory Patrol Scrub option is set to Standard .
  • Memory Refresh Rate : Sets the memory refresh rate to either 1x or 2x. By default, the Memory Refresh Rate option is set to 1x .
  • Uncore Frequency : Selects the Processor Uncore Frequency . Dynamic mode allows the processor to optimize power resources across the cores and uncore during runtime. The optimization of the uncore frequency to either save power or optimize performance is influenced by the setting of the Energy Efficiency Policy .
  • Energy Efficient Policy : Enables you to selects the Energy Efficient Policy . The CPU uses the setting to manipulate the internal behavior of the processor and determines whether to target higher performance or better power savings.
  • Number of Turbo Boot Enabled Cores for Processor 1 :

Controls the number of turbo boost enabled cores for processor 1. By default, the maximum number of cores is enabled. • Monitor/Mwait: Enables the Monitor/Mwait instructions in the processor. By default, the Monitor/Mwait option is set to Enabled for all system profiles, except Custom.

Menu Item Description

Page 39 of the Dell XC730xd user manual — Editing system security
Page 39 · click to enlarge
Page 39

Editing system security

You can use the System Security screen to edit some settings such as setting the system password, setup password and disabling the power button.

1. Go to System Setup Main Menu , and then click System BIOS .
2. On System BIOS , click System Security .

The System Security screen is displayed.

System security screen settings

The System Security Settings screen details are explained as follows:

Table 21. System security settings

Intel AES-NI Improves the speed of applications by performing encryption and decryption using the Advanced Encryption Standard Instruction Set and is set to Enabled by default.

System Password Sets the system password. This option is set to Enabled by default and is read-only if the password jumper is not installed in the system.

Setup Password Sets the setup password. This option is read-only if the password jumper is not installed in the system.

Password Status Locks the system password. By default, the Password Status option is set to Unlocked.

Allows you to control the reporting mode of the Trusted Platform Module (TPM). By default, the TPM Security option is set to Off. You can only modify the TPM Status, TPM Activation , and Intel TXT fields if the TPM Status field is set to either On with Pre-boot Measurements or On without Pre-boot Measurements.

TPM Information Changes the operational state of the TPM. By default, the TPM Activation option is set to No Change.

TPM Status Displays the TPM status.

Clears all the contents of the TPM. By default, the TPM Clear option is set to No.

Show 4 more labels / short text on this page
Menu Item Description · Menu Item Description · TPM Security · TPM Command
Page 40 of the Dell XC730xd user manual — Editing system security
Page 40 · click to enlarge
Page 40

Intel TXT Enables or disables the Intel Trusted Execution Technology (TXT). To enable Intel TXT, Virtualization Technology must be enabled and TPM Security must be Enabled with Pre-boot measurements. By default, the Intel TXT option is set to Off

Power Button Enables or disables the Power button on the front of the system. By default, the Power Button option is set to Enabled.

NMI Button Enables or disables the NMI button on the front of the system. By default, the NMI Button option is set to Disabled.

AC Power Recovery Sets how the system reacts after AC power is restored to the system. By default, the AC Power Recovery option is set to Last.

AC Power Recovery Delay Sets how the system supports staggering of power up after AC power is restored to the system. By default, the AC Power Recovery Delay option is set to Immediate.

User Defined Delay (60s to 240s) Sets the User Defined Delay when the User Defined option for AC Power Recovery Delay is selected.

UEFI Variable Access Provides varying degrees of securing UEFI variables. When set to Standard (the default) UEFI variables are accessible in the Operating System per the UEFI specification. When set to Controlled, selected UEFI variables are protected in the environment and new UEFI boot entries are forced to be at the end of the current boot order.

Secure Boot Enables Secure Boot, where the BIOS authenticates each pre-boot image using the certificates in the Secure Boot Policy. Secure Boot is disabled by default.

Secure Boot Policy When Secure Boot policy is Standard, the BIOS uses the system manufacturer’s key and certificates to authenticate pre-boot images. When Secure Boot policy is Custom, the BIOS uses the user-defined key and certificates. Secure Boot policy is Standard by default.

Secure Boot Policy Summary

Displays the list of certificates and hashes that secure boot uses to authenticate images.

Secure Boot Custom Policy Settings screen

Secure Boot Custom Policy Settings is displayed only when Secure Boot Policy is set to Custom. In the System Setup Main Menu, click System BIOS → System Security → Secure Boot Custom Policy Settings.

The Secure Boot Custom Policy Settings screen details are explained as follows:

Table 22. Secure boot custom policy settings

Platform Key Imports, exports, deletes, or restores the platform key (PK).

Key Exchange Key Database Allows you to import, export, delete, or restore entries in the Key Exchange Key (KEK) Database.

Authorized Signature Database Imports, exports, deletes, or restores entries in the Authorized Signature Database (db).

Menu Item Description · Menu Item Description

Page 41 of the Dell XC730xd user manual — Editing miscellaneous settings
Page 41 · click to enlarge
Page 41

Forbidden Signature Database Imports, exports, deletes, or restores entries in the Forbidden Signature Database (dbx).

Editing miscellaneous settings

You can use the Miscellaneous Settings screen to perform some configurations such as updating the asset tag, and changing the system date and time.

1. Go to System Setup Main Menu , and then click System BIOS .
2. On System BIOS , click Miscellaneous Settings .

The Miscellaneous Settings screen displays.

The Miscellaneous Settings screen details are explained as follows:

Table 23. Miscellaneous settings

System Time System Time lets you set the time on the system.

System Date System Date lets you set the date on the system.

Asset Tag Displays the asset tag and lets you to modify it for security and tracking purposes.

Keyboard NumLock Keyboard NumLock lets you set whether the system boots with the NumLock enabled or disabled. By default the Keyboard NumLock is set to On.

F1/F2 Prompt on Error Enables or disables the F1/F2 prompt on error. By default, F1/F2 Prompt on Error is set to Enabled. The F1/F2 prompt also includes keyboard errors.

Load Legacy Video Option ROM You can determine whether the system BIOS loads the legacy video (INT 10H) option ROM from the video controller. Selecting Enabled in the operating system does not support UEFI video output standards. This field is only for UEFI boot mode. You cannot set this to Enabled if UEFI Secure Boot mode is enabled.

In-System Characterization This option enables or disables In-System Characterization. By default, In-System Characterization is set to Disabled. The two other options are Enabled and Enabled - No Reboot.

Menu Item Description · Miscellaneous settings screen · Menu Item Description

Page 42 of the Dell XC730xd user manual — Boot Manager main menu
Page 42 · click to enlarge
Page 42

When enabled, In-System Characterization (ISC) runs during POST upon detecting relevant change(s) in system configuration to optimize system power and performance. ISC takes about 20 seconds to run, and system reset is required for ISC results to be applied. The Enabled - No Reboot option runs ISC and continues without applying ISC results until the next time system reset occurs. The Enabled option runs ISC and forces an immediate system reset so that ISC results can be applied. It takes the system longer to be ready due to the forced system reset. When disabled, ISC does not run.

About Boot Manager

With Boot Manager you can add, delete, and arrange boot options. You can also access System Setup and boot options without restarting the system.

Entering Boot Manager

The Boot Manager screen allows you to select boot options and diagnostic utilities.

1. Turn on or restart your system.
2. Press F11 when you see the message = Boot Manager .

If your operating system begins to load before you press F11, allow the system to finish booting, and then restart your system and try again.

Boot Manager main menu

Table 24. Boot manager main menu

Continue Normal Boot The system attempts to boot to devices starting with the first item in the boot order. If the boot attempt fails, the system continues with the next item in the boot order until the boot is successful or no more boot options are found.

One Shot Boot Menu Takes you to the boot menu where you can select a one time boot device to boot from.

Launch System Setup Allows you to access the System Setup.

Launch Lifecycle Controller Exits the Boot Manager and invokes the Lifecycle Controller program.

System Utilities Launches system utilities menu such as system diagnostics and UEFI shell.

Menu Item Description · Menu Item Description

Page 43 of the Dell XC730xd user manual — Assigning a system and setup password
Page 43 · click to enlarge
Page 43

Changing the boot order

You may have to change the boot order if you want to boot from a USB key or an optical drive. The instructions given below may vary if you have selected BIOS for Boot Mode.

1. In the System Setup Main Menu , click System BIOS → Boot Settings .
2. Click Boot Option Settings → Boot Sequence .
3. Use the arrow keys to select a boot device, and use the + and - keys to move the device down or up in the order.
4. Click Exit , click Yes to save the settings on exit.

Choosing the system boot mode

With System Setup, you can to specify the boot mode for installing your operating system:

  • BIOS boot mode (the default) is the standard BIOS-level boot interface.
  • UEFI boot mode is an enhanced 64-bit boot interface based on Unified Extensible Firmware Interface (UEFI) specifications that overlays the system BIOS.

You must select the boot mode in the Boot Mode field of the Boot Settings screen of System Setup. Once you specify the boot mode, the system boots in the specified boot mode and you then proceed to install your operating system from that mode. Thereafter, you must boot the system in the same boot mode (BIOS or UEFI) to access the installed operating system. Trying to boot the operating system from the other boot mode causes the system to halt at startup.

Assigning a system and setup password

You can assign a new System Password and Setup Password or change an existing System Password and Setup Password only when the password jumper setting is enabled and Password Status is Unlocked.

If the password jumper setting is disabled, the existing System Password and Setup Password are deleted and you need not provide the system password to boot the system.

About this task To assign a System Password and Setup Password, follow the steps below:

Steps 1. To enter System Setup, press F2 immediately after a power-on or reboot.

2. From the System Setup Main Menu , select System BIOS and press Enter.
Page 44 of the Dell XC730xd user manual — Deleting or changing an existing system password and setup password
Page 44 · click to enlarge
Page 44
3. On the System BIOS screen, select System Security and press Enter.
4. On the System Security screen, verify that Password Status is Unlocked .
5. Select System Password , enter your system password, and press Enter or Tab.

Use the following guidelines to assign the system password:

  • A password can have up to 32 characters.
  • The password can contain the numbers 0 through 9.
  • Only the following special characters are allowed: space, (”), (+), (,), (-), (.), (/), (;), ([), (\), (]), (`).

A message prompts you to re-enter the system password.

6. Re-enter the system password, and click OK .
7. Select Setup Password , enter your system password and press Enter or Tab.

A message prompts you to re-enter the setup password.

8. Re-enter the setup password, and click OK .
9. Press Esc to return to the System BIOS screen. Press Esc again.

A message prompts you to save the changes.

Deleting or changing an existing system password and setup password

Prerequisites Ensure that the Password jumper is set to enabled and the Password Status is Unlocked before attempting to delete or change the existing System and/or Setup password. You cannot delete or change an existing System or Setup password if the Password Status is Locked.

Steps 1. To enter System Setup, press F2 immediately after a power on or restart.

2. From the System Setup Main Menu , select System BIOS and press Enter.

The System BIOS screen is displayed.

3. On the System BIOS Screen , select System Security and press Enter.

The System Security screen is displayed.

4. On the System Security screen, verify that Password Status is Unlocked .
5. Select System Password , alter or delete the existing system password and press Enter or Tab.
6. Select Setup Password , alter or delete the existing setup password and press Enter or Tab.

If you change the System and Setup password a message prompts you to re-enter the new password. If you delete the System and Setup password, a message prompts you to confirm the deletion.

7. Press Esc to return to the System BIOS screen. Press Esc again, and a message prompts you to save the changes.
Page 45 of the Dell XC730xd user manual — After working inside your system
Page 45 · click to enlarge
Page 45

4 Installing and removing system components

Safety instructions

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

Before working inside your system

1. Turn off the system, including any attached peripherals.
2. Disconnect the system from the electrical outlet and disconnect the peripherals.
3. If installed, remove the front bezel.

For more information, see Removing the front bezel.

4. Remove the system cover.

For more information, see Removing the system cover.

After working inside your system

1. Install the system cover.

For more information, see Installing the system cover.

2. Install the optional bezel.
Page 46 of the Dell XC730xd user manual — Removing the front bezel
Page 46 · click to enlarge
Page 46

For more information, see Installing the front bezel.

3. Reconnect the system to its electrical outlet and peripherals.
4. Turn the system on, including any attached peripherals.

Recommended tools

You need the following tools to perform the removal and installation procedures:

  • Key to the bezel lock. This is only required when you have a bezel.
  • #2 Phillips screwdriver
  • #1 Phillips screwdriver
  • T6, T8, T10, and T15 Torx screwdrivers

The following tools are required for assembling cables for a DC power supply unit (PSU):

  • AMP 90871-1 hand-crimping tool or equivalent
  • Tyco Electronics 58433-3 or equivalent
  • Wire-stripper pliers capable of removing insulation from size 10 AWG solid or stranded, insulated copper wire

Front bezel

Removing the front bezel

1. Unlock the bezel lock at the left end of the bezel.
2. Lift the release latch next to the bezel lock.
3. Pull the left end of the bezel, unhook the right end and remove the bezel.
Page 47 of the Dell XC730xd user manual — Removing the system cover
Page 47 · click to enlarge
Page 47
Dell XC730xd — Installing the front bezel diagram (page 47)
Fig. 10 · Installing the front bezel

Figure 10. Removing and installing the front bezel

Installing the front bezel

1. Hook the right end of the bezel onto the chassis.
2. Fit the free end of the bezel onto the system.
3. Secure the bezel with the keylock.
Dell XC730xd — Installing the front bezel diagram (page 47)
Fig. 11 · Installing the front bezel

http://www.Dell.com/XCSeries/XC730xd/Bezel

Removing the system cover

1. Ensure that you read the Safety instructions .
2. Turn off the system, including any attached peripherals.
3. Disconnect the system from the electrical outlet and peripherals.
4. Remove the optional bezel. For more information see Removing the front bezel .
1. Rotate the latch release lock counter clockwise to the unlocked position.
2. Lift the latch and rotate the latch toward the back of the system.

Related video · Steps

Page 48 of the Dell XC730xd user manual — Installing the system cover
Page 48 · click to enlarge
Page 48

The system cover slides back and the tabs on the system cover disengages from the slots on the chassis.

3. Hold the cover on both sides, and lift the cover away from the system.
Dell XC730xd — Installing the system cover diagram (page 48)
Fig. 12 · Installing the system cover

Figure 11. Removing and installing the system cover

1. system cover 2. latch
3. latch release lock
Dell XC730xd — Installing the system cover diagram (page 48)
Fig. 13 · Installing the system cover

http://www.Dell.com/XCSeries/XC730xd/Cover

Installing the system cover

Prerequisites Ensure that you read the Safety instructions.

Related videos

Page 49 of the Dell XC730xd user manual — Inside the system
Page 49 · click to enlarge
Page 49

Steps 1. Align the slots of the system cover with the tabs on the chassis.

2. Press the cover release latch, and push the cover toward the front of the chassis until the latch locks into place.
3. Turn the latch release lock clockwise to the locked position.
4. Install the optional bezel.
5. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.

Inside the system

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

Page 50 of the Dell XC730xd user manual — Cooling shroud
Page 50 · click to enlarge
Page 50
Dell XC730xd — Cooling shroud diagram (page 50)
Fig. 14 · Cooling shroud

Figure 12. Inside the system—Dell XC730xd

1. cooling-fan in the cooling-fan assembly (6) 2. processor (2)
3. DIMMs (24) 4. internal USB port
5. hard-drive backplane (back) 6. vFlash media slot
7. hard drive (2) (back) 8. power supply unit (2)
9. expansion-card riser 3 10. network daughter card
11. expansion-card riser 2 12. expansion-card riser 1
13. hard-drive backplane

Cooling shroud

Page 51 of the Dell XC730xd user manual — Installing the cooling shroud
Page 51 · click to enlarge
Page 51

Removing the cooling shroud

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

1. Ensure that you read the Safety instructions .
2. Follow the procedure listed in Before working inside your system .

Hold the shroud and lift it away from the system.

Dell XC730xd — Removing the cooling shroud diagram (page 51)
Fig. 15 · Removing the cooling shroud

Figure 13. Removing and installing the cooling shroud

1. cooling shroud 2. touch point (2)
1. Replace the cooling shroud. See Installing the cooling shroud .
2. Follow the procedure listed in After working inside your system .

Installing the cooling shroud

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

Steps · Next steps

Page 52 of the Dell XC730xd user manual — Removing a cooling fan
Page 52 · click to enlarge
Page 52
1. Ensure that you read the Safety instructions .
2. Route the cables inside the system along the chassis wall and secure the cables using the cablesecuring bracket.

Steps 1. Align the tabs on the cooling shroud with the securing slots on the chassis.

2. Lower the cooling shroud into the chassis until it is firmly seated.
1. Follow the procedure listed in After working inside your system .

Cooling fans

Your system supports six hot-swappable cooling fans.

Removing a cooling fan

1. Ensure that you read the Safety instructions .
2. Follow the procedure listed in Before working inside your system .

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

Press the fan release tab and lift the cooling fan out of the cooling-fan assembly.

Next steps · Steps

Page 53 of the Dell XC730xd user manual — Installing a cooling fan
Page 53 · click to enlarge
Page 53
Dell XC730xd — Installing a cooling fan diagram (page 53)
Fig. 16 · Installing a cooling fan

Figure 14. Removing and installing a cooling fan

1. cooling-fan assembly 2. cooling-fan connector (6)
3. fan release tab (6) 4. cooling fan (6)
5. cooling-fan connector on system board (6)
1. Replace the cooling fan. See Installing a cooling fan
2. Follow the procedure listed in After working inside your system .
Dell XC730xd — Installing a cooling fan diagram (page 53)
Fig. 17 · Installing a cooling fan

http://www.Dell.com/XCSeries/XC730xd/Fans

Installing a cooling fan

1. Ensure that you read the Safety instructions .
2. Follow the procedure listed in Before working inside your system .

Next steps · Related videos

Page 54 of the Dell XC730xd user manual — Removing the cooling-fan assembly
Page 54 · click to enlarge
Page 54

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

Steps 1. Align the plug at the base of the cooling fan with the connector on the system board.

2. Slide the cooling fan into the securing slots until the tabs lock into place.

Follow the procedure listed in After working inside your system.

Cooling-fan assembly

Removing the cooling-fan assembly

1. Ensure that you read the Safety instructions .
2. Follow the procedure listed in Before working inside your system .

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

Steps 1. Unlock the cooling-fan assembly from the chassis by lifting the release levers upward.

2. Lift the cooling-fan assembly out of the chassis.

Next steps

Page 55 of the Dell XC730xd user manual — Installing the cooling-fan assembly
Page 55 · click to enlarge
Page 55
Dell XC730xd — Installing the cooling-fan assembly diagram (page 55)
Fig. 18 · Installing the cooling-fan assembly

Figure 15. Removing and installing the cooling-fan assembly

1. cooling-fan assembly 2. cooling fan (6)
3. release lever (2) 4. guide pin on the system board (2)
5. cooling-fan connector (6) 6. guide pin on the chassis (6)
1. Replace the cooling-fan assembly. See Installing the cooling-fan assembly
2. Follow the procedure listed in After working inside your system .

Installing the cooling-fan assembly

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

1. Ensure that you read the Safety instructions .
2. Follow the procedure listed in Before working inside your system .

Next steps

Page 56 of the Dell XC730xd user manual — System memory
Page 56 · click to enlarge
Page 56

Steps 1. Align the cooling-fan assembly slots with the guide pins on the chassis.

2. Slide the cooling-fan assembly into the chassis.
3. Lock the cooling-fan assembly into the chassis by lowering the release levers until firmly seated.

Follow the procedure listed in After working inside your system.

System memory

Your system supports DDR4 registered DIMMs (RDIMMs), and load reduced DIMMs (LRDIMMs).

Memory bus operating frequency can be 1333 MT/s, 1600 MT/s, 1866 MT/s, or 2133 MT/s depending on the following factors:

  • DIMM type (RDIMM or LRDIMM)
  • Number of DIMMs populated per channel
  • System profile selected (for example, Performance Optimized, Custom, or Dense Configuration Optimized)
  • Maximum supported DIMM frequency of the processors

The system contains 24 memory sockets split into two sets of 12 sockets, one set per processor. Each 12- socket set is organized into four channels. In each channel, the release levers of the first socket are marked white, the second socket black, and the third socket green.

Next steps

Page 57 of the Dell XC730xd user manual — System memory
Page 57 · click to enlarge
Page 57
Dell XC730xd — System memory diagram (page 57)
Fig. 19 · System memory

Figure 16. Memory socket locations

Page 58 of the Dell XC730xd user manual — System memory
Page 58 · click to enlarge
Page 58
Dell XC730xd — System memory diagram (page 58)
Fig. 20 · System memory

Figure 17. Memory socket locations

Memory channels are organized as follows:

Processor 1 channel 0slots A1, A5, and A9
channel 1slots A2, A6, and A10
channel 2slots A3, A7, and A11
channel 3slots A4, A8, and A12
Processor 2 channel 0slots B1, B5, and B9
channel 1slots B2, B6, and B10
channel 2slots B3, B7, and B11
Page 59 of the Dell XC730xd user manual — Sample memory configurations
Page 59 · click to enlarge
Page 59
channel 3slots B4, B8, and B12

The following table shows the memory populations and operating frequencies for the supported configurations.

Table 25. The memory populations and operating frequencies for the supported configurations.

DIMM Type DIMMs Populated/ Channel

RDIMM 1 2133, 1866, 1600, 1333 Dual rank or single rank

2 2133, 1866, 1600, 1333 Dual rank or single rank

3 1866, 1600, 1333 Dual rank or single rank

LRDIMM 1 2133, 1866, 1600, 1333 Quad rank

2 2133, 1866, 1600, 1333 Quad rank

3 1866, 1600, 1333 Quad rank

General memory module installation guidelines

This system supports Flexible Memory Configuration, you can configure and run the system in any valid chipset architectural configuration. The following are the recommended guidelines for installing memory modules:

  • RDIMMs and LRDIMMs must not be mixed.
  • x4 and x8 DRAM based DIMMs can be mixed..
  • Up to three dualor single-rank RDIMMs can be populated per channel.
  • Up to three LRDIMMs can be populated per channel regardless of rank count.
  • Populate DIMM sockets only if a processor is installed. For single-processor systems, sockets A1 to A12 are available. For dual-processor systems, sockets A1 to A12 and sockets B1 to B12 are available.
  • Populate all sockets with white release tabs first, then black, and then green.
  • Populate the sockets by highest rank count in the following order — first in sockets with white release levers, then black, and then green. For example, if you want to mix single-rank and dual-rank DIMMs, populate dual-rank DIMMs in the sockets with white release tabs and single-rank DIMMs in the sockets with black release tabs.
  • When mixing memory modules with different capacities, populate the sockets with memory modules with highest capacity first. For example, if you want to mix 4 GB and 8 GB DIMMs, populate 8 GB DIMMs in the sockets with white release tabs and 4 GB DIMMs in the sockets with black release tabs.
  • In a dual-processor configuration, the memory configuration for each processor should be identical. For example, if you populate socket A1 for processor 1, then populate socket B1 for processor 2, and so on.
  • Memory modules of different capacities can be mixed provided other memory population rules are followed (for example, 4 GB and 8 GB memory modules can be mixed).
  • Mixing of more than two DIMM capacities in a system is not supported.
  • Populate four DIMMs per processor (one DIMM per channel) at a time to maximize performance.

Sample memory configurations

The following tables show sample memory configurations for one and two processor configurations that follow the appropriate memory guidelines.

Operating Frequency (in · Maximum DIMM Rank/Channel · MT/s)

Page 60 of the Dell XC730xd user manual — Removing memory modules
Page 60 · click to enlarge
Page 60

Table 26. Memory configurations—two processors

System capacity (in GB)

DIMM size (in GB)

DIMM rank, organization, and frequency

64 16 4 2R, x4, 2133 MT/s,

A1, A2, B1, B2

2R, x4, 1866 MT/s,

128 16 8 2R, x4, 2133 MT/s,

A1, A2, A3, A4, B1, B2, B3, B4

2R, x4, 1866 MT/s,

256 16 16 2R, x4, 2133 MT/s,

A1, A2, A3, A4, A5, A6, A7, A8, B1, B2, B3, B4, B5, B6, B7, B8

2R, x4, 1866 MT/s,

384 16 24 2R, x4, 2133 MT/s,

A1, A2, A3, A4, A5, A6, A7, A8, A9, A10, A11, A12, B1, B2, B3, B4, B5, B6, B7, B8, B9, B10, B11, B12

2R, x4, 1866 MT/s,

512 32 16 LRDIMM, 4R, x4, 2133 MT/s

A1, A2, A3, A4, A5, A6, A7, A8, B1, B2, B3, B4, B5, B6, B7, B8

768 32 24 LRDIMM, 4R, x4, 1866 MT/s

A1, A2, A3, A4, A5, A6, A7, A8, A9, A10, A11, A12, B1, B2, B3, B4, B5, B6, B7, B8, B9, B10, B11, B12

LRDIMM, 4R, x4, 1600 MT/s

Removing memory modules

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

1. Ensure that you read the Safety instructions .
2. Follow the procedure listed in Before working inside your system .
3. Remove the cooling shroud.
4. If installed, remove the cooling-fan assembly. For more information, see Removing the cooling-fan assembly

Number of DIMMs · DIMM slot population

Page 61 of the Dell XC730xd user manual — Removing memory modules
Page 61 · click to enlarge
Page 61

Steps 1. Locate the appropriate memory module socket.

2. To release the memory module from the socket, simultaneously press the ejectors on both ends of the memory-module socket.
Dell XC730xd — Removing memory modules diagram (page 61)
Fig. 21 · Removing memory modules

Figure 18. Removing and installing a memory module

1. memory-module 2. memory-module socket
3. memory module socket ejector (2)
Dell XC730xd — Removing memory modules diagram (page 61)
Fig. 22 · Removing memory modules

http://www.Dell.com/XCSeries/XC730xd/DIMMS

Related videos

Page 62 of the Dell XC730xd user manual — Installing memory modules
Page 62 · click to enlarge
Page 62

Installing memory modules

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

1. Ensure that you read the Safety instructions .
2. Follow the procedure listed in Before working inside your system .
3. Remove the cooling shroud.
4. Removing the cooling-fan assembly.

Steps 1. Locate the appropriate memory-module socket.

2. If a memory module or a memory-module blank is installed in the socket, remove it.
3. Align the edge connector of the memory module with the alignment key of the memory module socket, and insert the memory module in the socket.
4. Press the memory module with your thumbs until the socket levers firmly click into place.
Page 63 of the Dell XC730xd user manual — SATADOM
Page 63 · click to enlarge
Page 63
Dell XC730xd — SATADOM diagram (page 63)
Fig. 23

Figure 19. Installing the memory module

1. memory module 2. alignment key
3. memory-module socket ejector (2)

When the memory module is properly seated in the socket, the levers on the memory module socket align with the levers on the other sockets that have memory modules installed.

5. Repeat steps 1 to 4 of this procedure to install the remaining memory modules.
1. Install the cooling shroud.
2. Follow the procedure listed in After working inside your system .
3. Press F2 to enter System Setup, and check the System Memory setting.

The system should have already changed the value to reflect the installed memory.

4. If the value is incorrect, one or more of the memory modules may not be installed properly. Repeat step 4 through step 5 of this procedure, checking to ensure that the memory modules are firmly seated in their sockets.
5. Run the system memory test in the system diagnostics.

SATADOM

A SATADOM is a disk-on-module (DOM) form factor with an incorporated standard SATA data connection. By default, the SATADOM comes with a power cable installed and is set in a Read/Write position.

The SATADOM uses an onboard SATA controller and does not require an additional controller.

With Nutanix, you can locate the boot device on a separate controller from the data drives, which improves system disk performance.

Next steps

Page 64 of the Dell XC730xd user manual — Removing the SATADOM
Page 64 · click to enlarge
Page 64

Removing the SATADOM

1. Ensure that you read the Safety instructions .
2. Follow the procedure listed in Before working inside your system .
3. Remove the cooling shroud prior to removing SATADOM. For information about removing the cooling shroud, see Removing the cooling shroud

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

Steps 1. Unplug the power cable from the SATADOM Tape Backup Unit (TBU) power connector.

2. Press the lock release on the SATADOM and pull it up and away from the system.
Page 65 of the Dell XC730xd user manual — Installing the SATADOM
Page 65 · click to enlarge
Page 65
Dell XC730xd — Installing the SATADOM diagram (page 65)
Fig. 24 · Installing the SATADOM

Figure 20. Removing and installing SATADOM

1. SATADOM 2. SATA connector
3. power cable 4. SATADOM TBU power connector

Next steps Follow the procedure listed in After working inside your system.

Installing the SATADOM

1. Ensure that you read the Safety instructions .
2. Follow the procedure listed in Before working inside your system .
3. Remove the cooling shroud prior to installing SATADOM. For information about removing the cooling shroud, see Removing the cooling shroud

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

Page 66 of the Dell XC730xd user manual — Removing a processor
Page 66 · click to enlarge
Page 66

Steps 1. Press the lock release on the SATADOM and plug the SATADOM into the preferred SATADOM connector on the system board.

2. Plug the power cable into the SATADOM TBU power connector on the system board.

Next steps Follow the procedure listed in After working inside your system.

Heat sinks and processors

Use the following procedure when:

  • Installing an additional processor
  • Replacing a processor

Removing a processor

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

1. Ensure that you read the Safety instructions .
2. Keep the #2 Phillips screwdriver handy.
3. If you are upgrading your system, download the latest system BIOS version from dell.com/support and follow the instructions included in the compressed download file to install the update on your system.
4. Follow the procedure listed in Before working inside your system .
5. If installed, remove the cooling fan assembly.
6. If installed, remove the full-length PCIe cards.
7. Remove the cooling shroud.

Steps 1. To remove the heat sink:

Page 67 of the Dell XC730xd user manual — Heat sinks and processors
Page 67 · click to enlarge
Page 67

a. Loosen one of the screws that secure the heat sink to the system board.

Wait 30 seconds for the heat sink to loosen from the processor. b. Remove the screw diagonally opposite the screw you first removed. c. Repeat the procedure for the remaining two screws. d. Remove the heat sink.

Dell XC730xd — Heat sinks and processors diagram (page 67)
Fig. 25 · Heat sinks and processors

Figure 21. Removing and installing a processor

1. heat sink 2. captive screws (4)
3. processor socket 4. slots (4)
Page 68 of the Dell XC730xd user manual — Heat sinks and processors
Page 68 · click to enlarge
Page 68
Dell XC730xd — Heat sinks and processors diagram (page 68)
Fig. 26 · Heat sinks and processors

Figure 22. Removing and installing a processor heat sink

1. captive screw (4) 2. heat sink
3. processor socket 4. slot (4)
Dell XC730xd — Heat sinks and processors diagram (page 68)
Fig. 27 · Heat sinks and processors

Figure 23. Removing and installing a processor heat sink

1. captive screw (4) 2. heat sink
3. processor socket 4. slot (4)
Page 69 of the Dell XC730xd user manual — Heat sinks and processors
Page 69 · click to enlarge
Page 69
Dell XC730xd — Heat sinks and processors diagram (page 69)
Fig. 28 · Heat sinks and processors

Figure 24. Processor shield

1. close first socket release lever 2. lock icon
3. processor 4. open first socket release lever
5. unlock icon
2. To remove the processor:

a. Release the open first socket-lever near the unlock icon

by pushing the lever down and out from under the tab.

b. Similarly, release the close first socket-release lever near the lock icon

by pushing the lever down and out from under the tab. Lift the lever 90 degrees upward. c. Lower the open first socket-release lever to lift the processor shield.

Page 70 of the Dell XC730xd user manual — Heat sinks and processors
Page 70 · click to enlarge
Page 70
Dell XC730xd — Heat sinks and processors diagram (page 70)
Fig. 29 · Heat sinks and processors

Figure 25. Removing and installing a processor

1. close first socket-release lever 2. pin-1 indicator of processor
3. processor 4. slot (4)
5. processor shield 6. open first socket-release lever
7. socket 8. socket keys (4)

d. Hold the tab on the processor shield and lift the processor shield until the open first socket-

release lever lifts up.

1. Replace the heat sinks and processors. See Installing a processor .
2. Follow the procedure listed in After working inside your system .

Next steps

Page 71 of the Dell XC730xd user manual — Installing a processor
Page 71 · click to enlarge
Page 71

Installing a processor

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

1. Ensure that you read the Safety instructions .
2. Keep the #2 Phillips screwdriver handy.
3. If you are upgrading your system, download the latest system BIOS version from dell.com/support and follow the instructions included in the compressed download file to install the update on your system.
4. Follow the procedure listed in Before working inside your system .
5. If installed, remove the cooling fan assembly.
6. If installed, remove the full-length PCIe card.
7. Remove the cooling shroud.

Steps 1. Remove the heat sink.

2. Remove the heat sink.
3. Unpack the new processor.

If the processor has previously been used in a system, remove any remaining thermal grease from the processor using a lint-free cloth.

4. Locate the processor socket.
5. If applicable, remove the socket protective cap.
6. Release the open first socket-release lever near the unlock icon

by pushing the lever down and out from under the tab.

7. Similarly, release the close first socket-release lever near the lock icon

by pushing the lever down and out from under the tab. Lift the lever 90 degrees upward.

8. Hold the tab near the lock symbol on the processor shield and lift it up and out of the way.
9. To install the processor in the socket:
Page 72 of the Dell XC730xd user manual — Installing a processor
Page 72 · click to enlarge
Page 72

a. Align the processor with the socket keys.

e. Lower the close first socket-release lever near the lock icon

and push it under the tab to lock it..

f. Similarly, lower the open first socket-release lever near the unlock icon

and push it under the tab to lock it.

10. To install the heat sink:

a. If applicable, remove the existing thermal grease from the heat sink using a clean lint-free cloth. b. Apply thermal grease on the top of the processor. Use the thermal-grease syringe included with

your processor kit to apply the grease in a thin spiral on the top of the processor as shown in the figure.

Dell XC730xd — Installing a processor diagram (page 72)
Fig. 30 · Installing a processor

Figure 26. Applying thermal grease on the top of the processor

1. processor 2. thermal grease
Page 73 of the Dell XC730xd user manual — Removing the PCIe card holder
Page 73 · click to enlarge
Page 73
3. thermal-grease syringe
1. Install the cooling shroud.
2. If applicable, install the PCIe card.
3. If applicable, install the cooling fan assembly.
4. Follow the procedure listed in After working inside your system .
5. While booting, press F2 to enter the System Setup and check that the processor information matches the new system configuration.
6. Run the system diagnostics to verify that the new processor operates correctly.

PCIe card holder

Removing the PCIe card holder

1. Ensure that you read the Safety instructions .
2. Follow the procedure listed in Before working inside your system .
3. If installed, remove the full-length PCIe card.

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

Steps 1. Press the release tab and slide the card holder toward the back of the chassis to release the PCIe card holder from the chassis.

2. Lift the PCIe card holder out of the chassis.

Next steps

Page 74 of the Dell XC730xd user manual — Installing the PCIe card holder
Page 74 · click to enlarge
Page 74
Dell XC730xd — Installing the PCIe card holder diagram (page 74)
Fig. 31 · Installing the PCIe card holder

Figure 27. Removing and installing the PCIe card holder

1. PCIe card holder 2. release tab
1. Replace the PCIe card holder. See Installing the PCIe card holder .
2. Follow the procedure listed in After working inside your system .

Installing the PCIe card holder

1. Ensure that you read the Safety instructions .
2. Follow the procedure listed in Before working inside your system .

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

Steps 1. Align the PCIe card holder with the notches and tabs on the power supply unit cage.

2. Press the release tab and slide PCIe card holder toward the front of the chassis until firmly seated.
1. If applicable, replace the full-length PCIe card.
2. Follow the procedure listed in After working inside your system .

Next steps · Next steps

Page 75 of the Dell XC730xd user manual — Opening and closing the PCIe card holder latch
Page 75 · click to enlarge
Page 75

Opening and closing the PCIe card holder latch

1. Ensure that you read the Safety instructions .
2. Follow the procedure listed in Before working inside your system .

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

Steps 1. To open the PCIe card holder latch, press the release tab.

2. To close the PCIe card holder latch, rotate the latch clockwise until it locks.
Dell XC730xd — Opening and closing the PCIe card holder latch diagram (page 75)
Fig. 32 · Opening and closing the PCIe card holder latch

Figure 28. Opening and closing the PCIe card holder latch

1. PCIe card holder 2. release tab
3. PCIe card holder

Follow the procedure listed in After working inside your system.

Next steps

Page 76 of the Dell XC730xd user manual — Removing the cable retention bracket
Page 76 · click to enlarge
Page 76

Cable retention bracket

Removing the cable retention bracket

1. Ensure that you read the Safety instructions .
2. Follow the procedure listed in Before working inside your system .
3. Remove the cooling shroud.
4. Remove the PCIe card holder.
5. Remove all cables routed through the cable retention bracket.

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

Steps 1. Pull the tab to release it from the notch and slide the cable retention bracket toward the front of the chassis to release it from the chassis.

2. Lift the cable retention bracket out of the chassis.
Dell XC730xd — Removing the cable retention bracket diagram (page 76)
Fig. 33 · Removing the cable retention bracket

Figure 29. Removing and installing the cable retention bracket

1. alignment pin (2) 2. tab
3. cable retention bracket
Page 77 of the Dell XC730xd user manual — Removing the integrated storage controller card
Page 77 · click to enlarge
Page 77
1. Replace the cable retention bracket. See Installing the cable retention bracket
2. Follow the procedure listed in After working inside your system .
Dell XC730xd — Installing the cable retention bracket diagram (page 77)
Fig. 34 · Installing the cable retention bracket

http://www.Dell.com/XCSeries/XC730xd/cabling

Installing the cable retention bracket

1. Ensure that you read the Safety instructions .
2. Follow the procedure listed in Before working inside your system .
3. Remove the cooling shroud.
4. Remove the PCIe card holder.

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

1. Align the cable retention bracket with the alignment pins on the chassis.
2. Slide the cable retention bracket along the chassis wall until the tab clicks and locks the slots.
3. Place all cables to be routed in the cable retention bracket.
1. Install the PCIe card holder.
2. Install the cooling shroud.
3. Follow the procedure listed in After working inside your system .

Integrated storage controller card

Your system includes a dedicated expansion-card slot on the system board for an integrated controller card. The integrated storage controller card provides the integrated storage subsystem for your system’s internal hard drives. The controller supports SAS and SATA hard drives as supported by the version of the storage controller included with your system.

Removing the integrated storage controller card

1. Ensure that you read the Safety instructions .
2. Follow the procedure listed in Before working inside your system .
Show 4 more labels / short text on this page
Next steps · Related video · Steps · Next steps
Page 78 of the Dell XC730xd user manual — Installing the cable retention bracket
Page 78 · click to enlarge
Page 78
3. Remove the cooling shroud.
4. Remove the expansion-card riser 1.
5. Keep the #2 Phillips screwdriver handy.

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

Steps 1. Loosen the screws that secure the integrated storage controller cable to the integrated storage- controller card connector on the system board.

2. Lift the integrated storage controller cable out.
3. Lift one end of the card and angle it to disengage the card from the integrated storage-controller card holder on system board.
4. Lift the card out of the chassis.
Dell XC730xd — Installing the cable retention bracket diagram (page 78)
Fig. 35 · Installing the cable retention bracket

Figure 30. Removing and installing the integrated storage controller card

1. integrated storage controller cable 2. integrated storage controller card
Page 79 of the Dell XC730xd user manual — Installing the integrated storage controller card
Page 79 · click to enlarge
Page 79
3. integrated storage-controller card connector on the system board
4. integrated storage controller card holder
1. Replace the expansion-card riser 1.
2. Replace the cooling shroud.
3. Follow the procedure listed in After working inside your system .

Installing the integrated storage controller card

1. Ensure that you read the Safety instructions .
2. Follow the procedure listed in Before working inside your system .
3. Remove the cooling shroud.
4. Remove the expansion-card riser 1.
5. Keep the #2 Phillips screwdriver handy.

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

1. Align the end of the integrated storage-controller card opposite the connector with the integrated storage-controller card holder.
2. Lower the connector side of the integrated storage-controller card into the integrated storagecontroller card connector on the system board.

Ensure that the tabs on the system board align with the screw holes on the integrated storage- controller card.

3. Align the screws on the integrated storage-controller card cable with the screw holes on the connector.
4. Tighten the screws to secure the integrated storage-controller card cable with the integrated storage-controller card connector on the system board.
1. Replace the expansion-card riser 1.
2. Replace the cooling shroud.
3. Follow the procedure listed in After working inside your system .
Dell XC730xd — Installing the integrated storage controller card diagram (page 79)
Fig. 36 · Installing the integrated storage controller card

Figure 31.

http://www.Dell.com/XCSeries/XC730xd/SC

Show 4 more labels / short text on this page
Next steps · Steps · Next steps · Related video
Page 80 of the Dell XC730xd user manual — Expansion card installation guidelines
Page 80 · click to enlarge
Page 80

Expansion cards and expansion-card risers

Expansion card installation guidelines

Depending on your system configuration:

The following PCI Express generation 3 expansion cards are supported:

Table 27. Supported expansion cards

Riser PCIe slot Processor connection

Height Length Link width Slot width

1 1 Processor 2 Low Profile Half Length x8 x16

1 2 Processor 2 Low Profile Half Length x8 x16

1 3 Processor 2 Low Profile Half Length x8 x16

2 4 Processor 2 Full Height Full Length x16 x16

2 5 Processor 1 Full Height Full Length x8 x16

3 (default) 6 Processor 1 Full Height Full Length x8 x16

3 (alternate) 6 Processor 1 Full Height Full Length x16 x16

3 (default) 7 Processor 1 Full Height Full Length x8 x16

The following table provides guidelines for installing expansion cards to ensure proper cooling and mechanical fit. The expansion cards with the highest priority should be installed first using the slot priority indicated. Install all other expansion cards in card priority and slot priority order.

Table 28. Expansion card installation order

Card priority Card type Slot priority Max allowed

1 PCIe Bridge 4 1

2 10 Gb NICs (full height) 4,6,5 3

10 Gb NICs (low profile) 2,3,1 3

3 1 Gb NICs (full height) 4,6,5 3

1 Gb NICs (low profile) 2,3,1 1

4 Integrated RAID integrated slot 1

5 NDC integrated slot 3

Page 81 of the Dell XC730xd user manual — Removing an expansion card from expansion-card riser 2 or 3
Page 81 · click to enlarge
Page 81

Removing an expansion card from expansion-card riser 2 or 3

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

1. Ensure that you read the Safety instructions .
2. Follow the procedure listed in Before working inside your system .
3. When removing a card from Riser 3, ensure that the PCIe holder latch is closed.

Steps 1. Disconnect any cables connected to the expansion card.

2. Lift the expansion-card latch out of the slot.
3. Hold the expansion card by its edges, and remove it from the expansion-card connector.
4. If you are removing the card permanently, install a metal filler bracket over the empty expansion slot opening and close the expansion-card latch.
5. Replace the expansion-card latch into the slot.
6. Close the expansion-card locking tabs.
Page 82 of the Dell XC730xd user manual — Installing an expansion card into the expansion-card riser 2 or 3
Page 82 · click to enlarge
Page 82
Dell XC730xd — Installing an expansion card into the expansion-card riser 2 or 3 diagram (page 82)
Fig. 37 · Installing an expansion card into the expansion-card…

Figure 32. Removing and installing an expansion card from expansion-card riser 2 or 3

1. expansion card 2. expansion-card latch
3. expansion-card riser 4. power connector
5. expansion-card connector

Follow the procedure listed in After working inside your system.

Dell XC730xd — Installing an expansion card into the expansion-card riser 2 or 3 diagram (page 82)
Fig. 38 · Installing an expansion card into the expansion-card…

http://www.Dell.com/XCSeries/XC730xd/PCI

Installing an expansion card into the expansion-card riser 2 or 3

1. Ensure that you read the Safety instructions .

Next steps · Related video

Page 83 of the Dell XC730xd user manual — Removing an expansion card from the expansion-card riser 1
Page 83 · click to enlarge
Page 83
2. Follow the procedure listed in Before working inside your system .

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

Steps 1. Unpack the expansion card and prepare it for installation.

For instructions, see the documentation accompanying the card.

2. Lift the expansion-card latch and remove the filler bracket.
3. Holding the card by its edges, position the card so that the connector on the expansion card aligns with the expansion-card connector on the riser.
4. Insert the card-edge connector firmly into the expansion-card connector until the card is fully seated.
5. Press the touch points to open the expansion-card locking tabs.
6. Replace the expansion-card latch.
7. If applicable, connect the cables to the expansion card.
1. Follow the procedure listed in After working inside your system .
2. Install any device drivers required for the card as described in the documentation for the card.

Removing an expansion card from the expansion-card riser 1

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

1. Ensure that you read the Safety instructions .
2. Follow the procedure listed in Before working inside your system .
3. Disconnect any cables connected to the expansion card.
4. Remove the expansion-card riser.

Steps 1. Press tab A and rotate the latch clockwise.

2. Press tab B and rotate the latch downward.
3. Remove the expansion card from the expansion-card riser.
4. If you are removing the card permanently, install a metal filler bracket over the empty expansion slot opening and close the expansion-card latch.
5. Close the latches of tab A and tab B.

Next steps

Page 84 of the Dell XC730xd user manual — Installing an expansion card into the expansion-card riser 1
Page 84 · click to enlarge
Page 84
Dell XC730xd — Installing an expansion card into the expansion-card riser 1 diagram (page 84)
Fig. 39 · Installing an expansion card into the expansion-card…

Figure 33. Removing and installing an expansion-card from expansion-card riser 1

1. tab A 2. expansion-card riser 1 cage
3. expansion-card connector 4. tab B
5. latch 6. expansion card
1. Install the expansion-card riser. For more information, see Installing expansion-card risers .
2. Follow the procedure listed in After working inside your system .

Installing an expansion card into the expansion-card riser 1

1. Ensure that you read the Safety instructions .
2. Follow the procedure listed in Before working inside your system .
3. Remove the expansion-card riser.

Next steps

Page 85 of the Dell XC730xd user manual — Removing expansion-card risers
Page 85 · click to enlarge
Page 85

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

Steps 1. Unpack the expansion card and prepare it for installation.

For instructions, see the documentation accompanying the card.

2. Press tab A and rotate the latch clockwise.
3. Press tab B and rotate the latch down.
4. Holding the card by its edges, position the card so that the card-edge connector aligns with the expansion-card connector.
5. Insert the card-edge connector firmly into the expansion-card connector until the card is fully seated.
6. Close the latches of tab A and tab B.
1. Install the expansion-card riser. For more information, see Installing expansion-card risers .
2. If applicable, connect any cables to the expansion card.
3. Follow the procedure listed in After working inside your system .
4. Install any device drivers required for the card as described in the documentation for the card.

Removing expansion-card risers

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

1. Ensure that you read the Safety instructions .
2. Follow the procedure listed in Before working inside your system .
3. If installed, remove any expansion card installed on riser 2 and 3.

Holding the slots on the expansion-card riser, lift the riser from the riser connector on the system board.

Next steps · Steps

Page 86 of the Dell XC730xd user manual — Removing expansion-card risers
Page 86 · click to enlarge
Page 86
Dell XC730xd — Removing expansion-card risers diagram (page 86)
Fig. 40 · Removing expansion-card risers

Figure 34. Removing and installing the expansion card riser 1

1. expansion-card riser 1 cage 2. expansion-card riser 1
3. riser guide-back (right) 4. riser guide-back (left)
5. expansion-card riser 1 connector 6. riser guide-front
Page 87 of the Dell XC730xd user manual — Removing expansion-card risers
Page 87 · click to enlarge
Page 87
Dell XC730xd — Removing expansion-card risers diagram (page 87)
Fig. 41 · Removing expansion-card risers

Figure 35. Identifying connectors on the expansion card riser 1

1. expansion-card slot 1 2. expansion-card slot 2
3. expansion-card slot 3
Page 88 of the Dell XC730xd user manual — Removing expansion-card risers
Page 88 · click to enlarge
Page 88
Dell XC730xd — Removing expansion-card risers diagram (page 88)
Fig. 42 · Removing expansion-card risers

Figure 36. Removing and installing the expansion card riser 2

1. power connector 2. expansion-card riser 2
3. riser guide-back 4. expansion-card riser 2 connector
5. riser guide-front
Page 89 of the Dell XC730xd user manual — Removing expansion-card risers
Page 89 · click to enlarge
Page 89
Dell XC730xd — Removing expansion-card risers diagram (page 89)
Fig. 43 · Removing expansion-card risers

Figure 37. Identifying connectors on the expansion card riser 2

1. expansion-card slot 4 2. expansion-card slot 5
3. power connector
Page 90 of the Dell XC730xd user manual — Removing expansion-card risers
Page 90 · click to enlarge
Page 90
Dell XC730xd — Removing expansion-card risers diagram (page 90)
Fig. 44 · Removing expansion-card risers

Figure 38. Removing and installing the expansion card riser 3

1. riser guide-front 2. power connector
3. expansion-card riser 3 4. riser guide-back
5. expansion-card riser 3 connector
Page 91 of the Dell XC730xd user manual — Removing expansion-card risers
Page 91 · click to enlarge
Page 91
Dell XC730xd — Removing expansion-card risers diagram (page 91)
Fig. 45 · Removing expansion-card risers

Figure 39. Identifying connectors on the expansion card riser 3 (default)

1. expansion-card slot 6 2. expansion-card slot 7
3. power connector
Dell XC730xd — Removing expansion-card risers diagram (page 91)
Fig. 46 · Removing expansion-card risers

Figure 40. Identifying connectors on the expansion card riser 3 (alternate)

1. expansion-card slot 6 2. power connector
1. If applicable, remove or install an expansion card on the riser.
2. If applicable, replace the expansion-card riser.
3. Follow the procedure listed in After working inside your system .

Next steps

Page 92 of the Dell XC730xd user manual — Removing an internal SD card
Page 92 · click to enlarge
Page 92

Installing expansion-card risers

1. Ensure that you read the Safety instructions .
2. Follow the procedure listed in Before working inside your system .
3. If applicable, reinstall the expansion cards into the expansion-card riser 1.

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

Steps 1. Align the expansion-card riser with the connectors and the riser guides on the system board.

2. Lower the expansion-card riser into place until the expansion-card riser is fully seated in the connector.
1. Install the expansion cards into the expansion-card risers 2 or 3.
2. Follow the procedure listed in After working inside your system .
3. Install any device drivers required for the card as described in the documentation for the card.

Internal dual SD module

Removing an internal SD card

1. Ensure that you read the Safety instructions .
2. Follow the procedure listed in Before working inside your system .

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

Locate the SD card slot on the internal dual SD module and press the card to release it from the slot.

Steps 1. Remove the PCIe Card.

2. Remove riser 3.
3. Locate the SD card slot on the internal dual SD module and press the card to release it from the slot.

Follow the procedure listed in After working inside your system.

Next steps · Next steps · Related videos

Page 93 of the Dell XC730xd user manual — Removing the internal dual SD module
Page 93 · click to enlarge
Page 93
Dell XC730xd — Installing an internal SD card diagram (page 93)
Fig. 47 · Installing an internal SD card

http://www.Dell.com/XCSeries/XC730xd/IDSDM

Installing an internal SD card

1. Ensure that you read the Safety instructions .
2. Follow the procedure listed in Before working inside your system .
3. If installed, remove the cooling shroud.

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

Steps 1. Locate the SD card connector on the internal dual SD module. Orient the SD card appropriately and insert the contact-pin end of the card into the slot.

2. Press the card into the card slot to lock it into place.

Follow the procedure listed in After working inside your system.

1. If removed, replace the cooling shroud.
2. Follow the procedure listed in After working inside your system .

Removing the internal dual SD module

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

1. Ensure that you read the Safety instructions .
2. Follow the procedure listed in Before working inside your system .

Steps 1. Locate the internal dual SD module on the system board.

2. If installed, remove the SD cards.
3. Hold the plastic pull tab and pull the dual SD module out of the system board.

Next steps

Page 94 of the Dell XC730xd user manual — Installing an internal SD card
Page 94 · click to enlarge
Page 94
Dell XC730xd — Installing an internal SD card diagram (page 94)
Fig. 48 · Installing an internal SD card

Figure 41. Removing and installing the Internal Dual SD Module (IDSDM)

1. Internal Dual SD module 2. LED status indicator (2)
3. SD card 4. SD card slot 2
5. SD card slot 1 6. IDSDM connector

Table 29. The following table describes the IDSDM indicator codes.

Convention IDSDM indicator code Description

A Green Indicates that the card is online

B Flashing green Indicates rebuild or activity

C Flashing amber Indicates card mismatch or that the card has failed

D Amber Indicates that the card is offline, has failed, or is write protected

Page 95 of the Dell XC730xd user manual — Removing the network daughter card
Page 95 · click to enlarge
Page 95

Convention IDSDM indicator code Description

E Not lit Indicates that the card is missing or is

Follow the procedure listed in After working inside your system

Installing the internal dual SD module

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

1. Ensure that you read the Safety instructions .
2. Follow the procedure listed in Before working inside your system

Steps 1. Locate the IDSDM connector on the system board. To locate the IDSDM connector, see System board connectors

2. Align the connectors on the system board and the dual SD module.
3. Push the dual SD module until it is firmly seated on the system board.
1. Install the SD vFlash media card(s).
2. Follow the procedure listed in After working inside your system

Network daughter card

Removing the network daughter card

1. Ensure that you read the Safety instructions .
2. Follow the procedure listed in Before working inside your system .
3. If installed, remove expansion card(s) from the expansion-card riser 2.
4. Keep the #1 Phillips screwdriver handy.

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

Next steps · Next steps

Page 96 of the Dell XC730xd user manual — Installing the internal dual SD module
Page 96 · click to enlarge
Page 96

Steps 1. Using a #1 Phillips screwdriver, loosen the captive screws that secure the network daughter card to the system board.

2. Hold the network daughter card by the edges on either side of the touch point and lift the card to remove it from the connector on the system board.
3. Slide the network daughter card away from the back of the system until the Ethernet connectors are clear of the slot in the back panel.
4. Lift the network daughter card out of the chassis.
Dell XC730xd — Installing the internal dual SD module diagram (page 96)
Fig. 49 · Installing the internal dual SD module

Figure 42. Removing and installing the Network Daughter Card (NDC)

1. captive screw socket (2) 2. connector on the system board
3. captive screw (2) 4. touch point (2)
5. network daughter card 6. back panel slot for Ethernet connectors
1. Replace the network daughter card. See Installing the network daughter card .
2. Follow the procedure listed in After working inside your system .

Next steps · Related videos

Page 97 of the Dell XC730xd user manual — Replacing the system battery
Page 97 · click to enlarge
Page 97
Dell XC730xd — Installing the network daughter card diagram (page 97)
Fig. 50 · Installing the network daughter card

http://www.Dell.com/XCSeries/XC730xd/NDC

Installing the network daughter card

1. Ensure that you read the Safety instructions .
2. Follow the procedure listed in Before working inside your system .
3. If applicable, remove the expansion card(s) in the expansion-card riser 2.
4. Keep the #1 Phillips screwdriver handy.

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

Steps 1. Angle the card so that the Ethernet connectors fit through the slot in the back panel.

2. Align the captive screws on the card with the captive screw sockets on the system board.
3. Press the touch points on the card until the card connector is firmly seated on the system board connector.
4. Using a #1 Phillips screwdriver, tighten the captive screws to secure the network daughter card to the system board.
1. If applicable, install the expansion card(s) in the expansion-card riser 2.
2. Follow the procedure listed in After working inside your system .

System battery

Replacing the system battery

1. Ensure that you read the Safety instructions .
2. Follow the procedure listed in Before working inside your system .
3. Remove the cooling shroud.

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

Next steps

Page 98 of the Dell XC730xd user manual — Installing the network daughter card
Page 98 · click to enlarge
Page 98

Steps 1. Locate the battery socket. For more information, see System board connectors.

2. Place your finger between the securing tabs at the negative side of the battery connector and lift the battery out of the socket.
Dell XC730xd — Installing the network daughter card diagram (page 98)
Fig. 51 · Installing the network daughter card

Figure 43. Removing the system battery

1. positive side of the battery connector 2. system battery 3. negative side of the battery connector
3. To install a new system battery, hold the battery with the "+" facing up and slide it under the securing tabs.
4. Press the battery into the connector until it snaps into place.
Page 99 of the Dell XC730xd user manual — Power supply units
Page 99 · click to enlarge
Page 99
Dell XC730xd — Power supply units diagram (page 99)
Fig. 52 · Power supply units

Figure 44. Installing the system battery

1. system battery 2. positive side of the battery
1. Install the cooling shroud.
2. Follow the procedure listed in After working inside your system .
3. While booting, press to enter System Setup and ensure the battery is operating properly.
4. Enter the correct time and date in System Setup Time and Date fields.
5. Exit System Setup.
Dell XC730xd — Power supply units diagram (page 99)
Fig. 53 · Power supply units

http://www.Dell.com/XCSeries/XC730xd/Battery

Power supply units

Your system supports one of the following:

  • Two 495 W, 750 W, or 1100 W AC power supply modules or
  • Two 1100 W DC power supply modules or
  • Two 750 W mixed mode power supply modules

Next steps · Related videos

Page 100 of the Dell XC730xd user manual — Removing the power supply unit blank
Page 100 · click to enlarge
Page 100

NOTE: When two identical PSUs are installed, power supply redundancy (1+1 – withredundancy or 2+0 – without redundancy) is configured in system BIOS. In redundant mode, power is supplied to the system equally from both PSUs when Hot Spare is disabled. When Hot Spare is enabled, one of the PSUs are put into standby when system usage is low to maximize efficiency.

Hot Spare feature

Your system supports the Hot Spare feature that significantly reduces the power overhead associated with power supply redundancy.

When the Hot Spare feature is enabled, one of the redundant power supplies is switched to a sleep state. The active power supply supports 100 percent of the load, thus operating at higher efficiency. The power supply in the sleep state monitors output voltage of the active power supply. If the output voltage of the active power supply drops, the power supply in the sleep state returns to an active output state.

If having both power supplies active is more efficient than having one power supply in a sleep state, the active power supply can also activate a sleeping power supply.

The default power supply settings are as follows:

  • If the load on the active power supply is more than 50 percent, then the redundant power supply is switched to the active state.
  • If the load on the active power supply falls below 20 percent, then the redundant power supply is switched to the sleep state

You can configure the Hot Spare feature using the iDRAC settings. For more information on iDRAC settings, see the Integrated Dell Remote Access Controller User’s Guide at dell.com/support/home

Removing the power supply unit blank

If you are installing a second power supply unit, remove the power supply unit blank in the bay by pulling the blank outward.

Page 101 of the Dell XC730xd user manual — Removing an AC power supply unit
Page 101 · click to enlarge
Page 101
Dell XC730xd — Installing the power supply unit blank diagram (page 101)
Fig. 54 · Installing the power supply unit blank

Figure 45. Removing and installing the power supply blank

1. power supply blank 2. power supply bay

Installing the power supply unit blank

Install the power supply unit blank only in the second power supply unit bay.

To install the power supply unit blank, align the blank with the power supply unit bay and push it into the chassis until it clicks into place.

Removing an AC power supply unit

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

Steps 1. Disconnect the power cable from the power source and from the power supply unit you intend to remove and remove the cables from the strap.

2. Press the release latch and slide the power supply unit out of the chassis.
Page 102 of the Dell XC730xd user manual — Installing an AC power supply unit
Page 102 · click to enlarge
Page 102
Dell XC730xd — Installing an AC power supply unit diagram (page 102)
Fig. 55 · Installing an AC power supply unit

Figure 46. Removing and installing an AC power supply unit

1. release latch 2. power supply unit cable connector
3. power supply unit 4. connector
5. power supply unit handle

Installing an AC power supply unit

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

Steps 1. Verify that both the power supply units are the same type and have the same maximum output power.

2. If applicable, remove the power supply unit blank.
3. Slide the new power supply unit into the chassis until the power supply unit is fully seated and the release latch snaps into place.
4. Connect the power cable to the power supply unit and plug the cable into a power outlet.
Page 103 of the Dell XC730xd user manual — Wiring instructions for a DC power supply unit
Page 103 · click to enlarge
Page 103

NOTE: When installing, hot-swapping, or hot-adding a new power supply unit, wait for 15 seconds for the system to recognize the power supply unit and determine its status. The power supply redundancy may not occur until discovery is complete. Wait until the new power supply unit is discovered and enabled before you remove the other power supply unit. The power- supply unit status indicator turns green to signify that the power supply unit is functioning properly.

Dell XC730xd — Wiring instructions for a DC power supply unit diagram (page 103)
Fig. 56 · Wiring instructions for a DC power supply unit

http://www.Dell.com/XCSeries/XC730xd/PSU

Wiring instructions for a DC power supply unit

Your system supports up to two –(48–60) V DC power supplies (when available).

WARNING: For equipment using –(48–60) V DC power supplies, a qualified electrician must perform all connections to DC power and to safety grounds. Do not attempt connecting to DC power or installing grounds yourself. All electrical wiring must comply with applicable local or national codes and practices. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow all safety instructions that came with the product.

  • Supply voltage: –(48–60) V DC
  • Current consumption: 32 A (maximum)
  • Dell part number 6RYJ9 terminal block or equivalent (1)
  • #6-32 nut equipped with lock washer (1)

Wire-stripper pliers capable of removing insulation from size 10 AWG solid or stranded, insulated copper wire

Show 4 more labels / short text on this page
Related videos · Input requirements · Kit contents · Required tools
Page 104 of the Dell XC730xd user manual — Removing a DC power supply unit
Page 104 · click to enlarge
Page 104
  • One UL 10 AWG, 2 m maximum (stranded) black wire [–(48–60) V DC]
  • One UL 10 AWG, 2 m maximum (stranded) red wire (V DC return)
  • One UL 10 AWG, 2 m maximum green/yellow, green with a yellow stripe, stranded wire (safety ground)

Removing a DC power supply unit

WARNING: For equipment using –(48–60) V DC power supplies, a qualified electrician must perform all connections to DC power and to safety grounds. Do not attempt connecting to DC power or installing grounds yourself. All electrical wiring must comply with applicable local or national codes and practices. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow all safety instructions that came with the product.

Steps 1. Disconnect the power wires from the power source and the connector from the power supply you intend to remove.

2. Disconnect the safety ground wire.
3. Press the release latch and slide the power supply out of the chassis.
Dell XC730xd — Removing a DC power supply unit diagram (page 104)
Fig. 57 · Removing a DC power supply unit

Figure 47. Removing and installing a DC power supply

1. release latch 2. power supply status indicator

Required wires

Page 105 of the Dell XC730xd user manual — Removing the system board
Page 105 · click to enlarge
Page 105
3. power supply 4. connector
5. power supply handle

Installing a DC power supply unit

WARNING: For equipment using –(48–60) V DC power supplies, a qualified electrician must perform all connections to DC power and to safety grounds. Do not attempt connecting to DC power or installing grounds yourself. All electrical wiring must comply with applicable local or national codes and practices. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow all safety instructions that came with the product.

Steps 1. Verify that both the power supplies are of the same type and have the same maximum output power.

2. Slide the new power supply unit into the chassis until the power supply unit is fully seated and the release latch snaps into place.
3. Connect the safety ground wire.
4. Install the DC power connector in the power supply unit.
5. Connect the wires to a DC power source.

System board

Removing the system board

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

CAUTION: If you are using the Trusted Platform Module (TPM) with an encryption key, you may be prompted to create a recovery key during program or System Setup. Be sure to create and safely store this recovery key. If you replace this system board, you must supply the recovery key when you restart your system or program before you can access the encrypted data on your hard drives.

Page 106 of the Dell XC730xd user manual — Installing a DC power supply unit
Page 106 · click to enlarge
Page 106
1. Ensure that you read the Safety instructions .
2. Follow the procedure listed in Before working inside your system .
3. Remove the following:

a. cooling shroud

b. cooling-fan assembly

c. hard-drive tray (if installed)

d. power supply unit(s)

e. all expansion-card risers

f. integrated storage controller card

g. internal dual SD module

h. internal USB key (if installed)

i. PCIe card holder

j. cable retention bracket

k. heat sink(s)/heat-sink blank(s)

l. processors(s)/processor blank(s)

m. memory modules and memory module blanks

n. network daughter card

Steps 1. Disconnect the mini SAS cable from the system board.

2. Disconnect all cables from the system board.
3. Hold the system-board holder, lift the blue release pin, lift the system board and slide it toward the front of the chassis.

Sliding the system board toward the front of the chassis disengages the connectors from the back of the chassis slots.

4. Lift the system board out of the chassis.
Page 107 of the Dell XC730xd user manual — Installing the system board
Page 107 · click to enlarge
Page 107
Dell XC730xd — Installing the system board diagram (page 107)
Fig. 58 · Installing the system board

Figure 48. Removing and installing the system board

1. release pin 2. system board
3. system-board holder
1. Replace the system board. See Installing the system board .
2. Follow the procedure listed in After working inside your system .

Installing the system board

1. Ensure that you read the Safety instructions .

Next steps

Page 108 of the Dell XC730xd user manual — Installing the system board
Page 108 · click to enlarge
Page 108
2. Follow the procedure listed in Before working inside your system .

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

Steps 1. Unpack the new system board assembly.

2. Hold the touch points and lower the system board into the chassis.
3. Push the system board toward the back of the chassis until the board clicks into place.
1. Install the Trusted Platform Module (TPM). For information on how to install TPM, see Installing the Trusted Platform Module . For more information on TPM, see Trusted Platform Module .
2. Replace the following:

a. Cable retention bracket

b. PCIe card holder

c. Hard-drive tray (if applicable)

d. Integrated storage controller card

e. Internal USB key (if applicable)

f. Internal dual SD module

g. All expansion-card risers

h. Heat sink(s)/heat-sink blank(s) and processors(s)/processor blank(s)

i. Memory modules and memory module blanks

j. Network daughter card

k. Cooling-fan assembly

l. Cooling shroud

m. Power supply unit(s)

3. Reconnect all cables to the system board.
4. Follow the procedure listed in After working inside your system .
5. Import your new or existing iDRAC Enterprise license. For more information, see Integrated Dell Remote Access Controller User's Guide , at dell.com/esmmanuals.
6. Ensure that you:

a. Use the Easy Restore feature to restore the Service Tag. For more information, see Restoring the Service Tag using Easy Restore.

Next steps

Page 109 of the Dell XC730xd user manual — Installing the system board
Page 109 · click to enlarge
Page 109

b. If the Service Tag is not backed up in the backup flash device, enter the system Service Tag manually. For more information, see Entering the system Service Tag using System Setup.

c. Update the BIOS and iDRAC versions.

d. Re-enable the Trusted Platform Module (TPM). For more information, see Re-enabling the TPM for TXT users.

Dell XC730xd — Installing the system board diagram (page 109)
Fig. 59 · Installing the system board

http://www.Dell.com/XCSeries/XC730xd/MOBO

Entering the system Service Tag using System Setup

If you know the system Service Tag, use the System Setup menu to enter the Service Tag.

1. Turn on the system.
2. Press F2 to enter the System Setup.
3. Click Service Tag Settings .
4. Enter the Service Tag.
5. Click Ok .
6. Import your new or existing iDRAC Enterprise license.

For more information, see Integrated Dell Remote Access Controller User's Guide, at dell.com/ esmmanuals.

Restoring the Service Tag using Easy Restore

Use the Easy Restore feature if you do not know the Service Tag of your system. The Easy Restore feature allows you to restore your system’s Service Tag, license, UEFI configuration, and the system configuration data after replacing the system board. All data is backed up in a backup flash device automatically. If BIOS detects a new system board and the Service Tag in the backup flash device, BIOS prompts the user to restore the backup information.

1. Turn on the system.

If BIOS detects a new system board, and if the Service Tag is present in the backup flash device, BIOS displays the Service Tag, the status of the license, and the UEFI Diagnostics version.

2. Do one of the following:
  • To restore the Service Tag, license, and diagnostics information, press Y .
  • To navigate to the Lifecycle Controller based restore options, press N
  • To restore data from a previously created Hardware Server Profile, press F10.

After the restore process is complete, BIOS prompts to restore the system configuration data.

3. Do one of the following:
  • Press Y to restore the system configuration data.
  • Press N to use the default configuration settings.

Related videos

Page 110 of the Dell XC730xd user manual — Installing the Trusted Platform Module
Page 110 · click to enlarge
Page 110

After the restore process is complete, the system restarts.

Trusted Platform Module

The Trusted Platform Module (TPM) is used to generate/store keys, protect/authenticate passwords, and create/store digital certificates. TPM can also be used to enable the BitLocker hard drive encryption feature in Windows Server.

Installing the Trusted Platform Module

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

Ensure that you read the Safety instructions.

Steps 1. Locate the TPM connector on the system board.

2. Align the edge connectors on the TPM with the slot on the TPM connector.
3. Insert the TPM into the TPM connector such that the plastic bolt aligns with the slot on the system board.
4. Press the plastic bolt until the bolt snaps into place.
Page 111 of the Dell XC730xd user manual — Re-enabling the TPM for TXT users
Page 111 · click to enlarge
Page 111
Dell XC730xd — Re-enabling the TPM for BitLocker users diagram (page 111)
Fig. 60 · Re-enabling the TPM for BitLocker users

Figure 49. Installing the TPM

1. TPM 2. TPM connector
3. slot on the TPM connector 4. plastic bolt
5. slot on the system board

Re-enabling the TPM for BitLocker users

Initialize the TPM.

For more information on initializing the TPM, see http://technet.microsoft.com/en-us/library/ cc753140.aspx.

The TPM Status changes to Enabled, Activated.

Re-enabling the TPM for TXT users

1. While booting your system, press F2 to enter System Setup.
2. In the System Setup Main Menu , click System BIOS → System Security Settings .
3. In the TPM Security option, select On with Pre-boot Measurements .
4. In the TPM Command option, select Activate .
5. Save the settings.
6. Restart your system.
7. Enter System Setup again.
8. In the System Setup Main Menu , click System BIOS → System Security Settings .
9. In the Intel TXT option, select On .
Page 112 of the Dell XC730xd user manual — Removing a 2.5 inch hard-drive blank
Page 112 · click to enlarge
Page 112

Hard drives

Your system supports Enterprise-class hard drives, which are designed for 24x7 operating environment. Selecting the correct drive class optimizes quality, functionality, performance, and reliability of the hard drives.

The Nutanix Web GUI provides a feature to help locate a specific HDD. When the front LEDs are turned on using the Nutanix Web GUI, the HDD or SSD you are trying to locate continues to blink as long as there is I/O activity. The other HDDs or SSDs blink twice every second (in addition to blinking because of I/O activity). The HDD or SSD you are trying to locate does not blink twice every second.

Due to industry advances, in some cases, the larger capacity drives have been changed to a larger sector size. The larger sector size can have impacts on operating systems and applications. For more information about these hard drives, see the 512e and 4Kn Disk Formats whitepaper and 4K Sector HDD FAQ document at dell.com/xcseriesmanuals

All hard drives are connected to the system board through the hard-drive backplane. Hard drives are supplied in hot-swappable hard-drive carriers that fit in the hard-drive slots.

Use only hard drives that have been tested and approved for use with the hard-drive backplane.

When you format a hard drive, allow enough time for the formatting to be completed. Be aware that high-capacity hard drives can take a number of hours to format.

Removing a 2.5 inch hard-drive blank

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

1. Ensure that you read the Safety instructions .
2. If installed, remove the bezel.

Press the release button and slide the hard-drive blank out of the hard-drive slot.

Steps

Page 113 of the Dell XC730xd user manual — Removing a 2.5 inch hard-drive blank (back)
Page 113 · click to enlarge
Page 113
Dell XC730xd — Installing a 2.5 inch hard-drive blank diagram (page 113)
Fig. 61 · Installing a 2.5 inch hard-drive blank

Figure 50. Removing and installing a 2.5 inch hard-drive blank

1. hard-drive blank 2. release button
Dell XC730xd — Installing a 2.5 inch hard-drive blank diagram (page 113)
Fig. 62 · Installing a 2.5 inch hard-drive blank

http://www.Dell.com/XCSeries/XC730xd/MidHDDs

Installing a 2.5 inch hard-drive blank

1. Ensure that you read the Safety instructions .
2. If installed, remove the front bezel.

Insert the hard-drive blank into the hard-drive slot until the release button clicks into place.

Next steps If applicable, install the front bezel.

Removing a 2.5 inch hard-drive blank (back)

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

Related video · Steps

Page 114 of the Dell XC730xd user manual — Removing a 3.5 inch hard-drive blank
Page 114 · click to enlarge
Page 114

Ensure that you read the Safety instructions.

Pull the hard-drive blank out until it is free of the hard-drive slot.

Dell XC730xd — Installing a 2.5 inch hard-drive blank (back) diagram (page 114)
Fig. 63 · Installing a 2.5 inch hard-drive blank (back)

Figure 51. Removing and installing a 2.5 inch hard-drive blank (back)

1. hard-drive blank (back)

Installing a 2.5 inch hard-drive blank (back)

1. Ensure that you read the Safety instructions .
2. If installed, remove the front bezel.

Insert the hard-drive blank into the hard-drive slot until it clicks into place.

Next steps Follow the procedure listed in After working inside your system.

Removing a 3.5 inch hard-drive blank

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

Steps · Steps

Page 115 of the Dell XC730xd user manual — Removing a hot-swap hard drive
Page 115 · click to enlarge
Page 115
1. Ensure that you read the Safety instructions .
2. If installed, remove the front bezel.

Press the release button and slide the blank out of the hard-drive slot.

Dell XC730xd — Installing a 3.5 inch hard-drive blank diagram (page 115)
Fig. 64 · Installing a 3.5 inch hard-drive blank

Figure 52. Removing and installing a 3.5 inch hard-drive blank

1. hard-drive blank 2. release button

Next steps If applicable, install the front bezel.

Installing a 3.5 inch hard-drive blank

1. Ensure that you read the Safety instructions .
2. If installed, remove the front bezel.

Insert the hard-drive blank into the hard-drive slot until the release button clicks into place.

Next steps If applicable, install the front bezel.

Removing a hot-swap hard drive

The Nutanix Web GUI provides a feature to help locate a specific HDD. When the front LEDs are turned on using the Nutanix Web GUI, the HDD or SSD you are trying to locate continues to blink as long as there is I/O activity. The other HDDs or SSDs blink twice every second (in addition to blinking because of I/O activity). The HDD or SSD you are trying to locate does not blink twice every second.

Steps · Steps

Page 116 of the Dell XC730xd user manual — Installing a 3.5 inch hard-drive blank
Page 116 · click to enlarge
Page 116

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

1. Ensure that you read the Safety instructions .
2. If applicable, remove the bezel.
3. If applicable, remove the system cover to remove hot-swap drives inside your system. Follow the procedure listed in Before working inside your system
4. Using the management software, prepare the hard drive for removal. Wait until the indicators on the hard-drive carrier signal that the hard drive can be removed safely. For more information, see the documentation for the storage controller.

If the hard drive is online, the green activity/fault indicator flashes as the drive is turned off. When the hard-drive indicators are off, the hard drive is ready for removal.

Steps 1. Press the release button to open the hard-drive carrier release handle.

2. Slide the hard-drive carrier out of the hard-drive slot.
3. If you are not replacing the hard drive immediately, insert a hard-drive blank in the empty hard-drive slot.
Dell XC730xd — Installing a 3.5 inch hard-drive blank diagram (page 116)
Fig. 65 · Installing a 3.5 inch hard-drive blank

Figure 53. Removing and installing a hot-swap hard drive

1. release button 2. hard-drive carrier
Page 117 of the Dell XC730xd user manual — Removing a hard drive from a hard-drive carrier
Page 117 · click to enlarge
Page 117
3. hard-drive carrier handle

Installing a hot-swap hard drive

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

Steps 1. If a HDD blank is installed in the HDD slot, remove it.

2. Install a HDD in the HDD carrier.
3. Press the release button on the front of the HDD carrier and open the HDD carrier handle.
4. Insert the HDD carrier into the HDD slot until the carrier connects with the backplane.
5. Close the HDD carrier handle to lock the HDD in place.

Removing a hard drive from a hard-drive carrier

1. Keep the #1 Phillips screwdriver handy.
2. Remove the hard-drive carrier from the system.

Steps 1. Remove the screws from the slide rails on the hard-drive carrier.

2. Lift the hard drive out of the hard-drive carrier.
Page 118 of the Dell XC730xd user manual — Removing the hard-drive backplane
Page 118 · click to enlarge
Page 118
Dell XC730xd — Installing a hard drive into a hard-drive carrier diagram (page 118)
Fig. 66 · Installing a hard drive into a hard-drive carrier

Figure 54. Removing and installing a hard drive into a hard-drive carrier

1. screw (4) 2. hard drive
3. hard-drive carrier

Installing a hard drive into a hard-drive carrier

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

Steps 1. Insert the hard drive into the hard-drive carrier with the connector end of the hard drive toward the back.

2. Align the screw holes on the hard drive with the set of screw holes on the hard-drive carrier.

When aligned correctly, the back of the hard drive is flush with the back of the hard-drive carrier.

3. Attach the screws to secure the hard drive to the hard-drive carrier.

Hard-drive backplane

Depending on your system configuration:

2.5 inch (x24) SAS/SATA backplane

3.5 inch (x12) SAS/SATA backplane

Removing the hard-drive backplane

1. Ensure that you read the Safety instructions .
2. Follow the procedure listed in Before working inside your system .
Page 119 of the Dell XC730xd user manual — Installing a hard drive into a hard-drive carrier
Page 119 · click to enlarge
Page 119
3. Remove the cooling shroud.
4. Remove the cooling-fan assembly.
5. Remove all hard drives.

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

Steps 1. Disconnect the SAS/SATA data, signal, and power cable(s) from the backplane.

2. Press the release tabs and lift the backplane upward and slide it toward the back of the chassis.
Page 120 of the Dell XC730xd user manual — Installing a hard drive into a hard-drive carrier
Page 120 · click to enlarge
Page 120
Dell XC730xd — Installing a hard drive into a hard-drive carrier diagram (page 120)
Fig. 67 · Installing a hard drive into a hard-drive carrier

Figure 55. Removing and installing the 2.5 inch (x24) SAS/SATA backplane

1. release tab (2) 2. left ear control panel cable
3. backplane power cable 4. hard-drive backplane expander
5. backplane signal cable 6. hard-drive backplane assembly
7. backplane power cable 8. mini SAS cable connector (2)
9. SAS cable (3) 10. control panel cable
11. USB cable 12. right ear control panel flex cable
13. hard-drive backplane connectors (24)
Page 121 of the Dell XC730xd user manual — Installing a hard drive into a hard-drive carrier
Page 121 · click to enlarge
Page 121
Dell XC730xd — Installing a hard drive into a hard-drive carrier diagram (page 121)
Fig. 68 · Installing a hard drive into a hard-drive carrier

Figure 56. Cabling diagram—2.5 Inch (x24) SAS/SATA backplane— (option 2)

1. hard-drive backplane expander 2. hard-drive backplane
3. backplane signal connector 1 4. system board
5. integrated storage controller card 6. SAS A1 connector
7. SAS B1 connector
Page 122 of the Dell XC730xd user manual — Installing the hard-drive backplane
Page 122 · click to enlarge
Page 122
Dell XC730xd — Installing the hard-drive backplane diagram (page 122)
Fig. 69 · Installing the hard-drive backplane

Figure 57. Removing and installing the 3.5 inch (x12) SAS/SATA backplane

1. release tab (2) 2. SAS cable A2
3. SAS cable A1 4. left ear control panel cable
5. backplane signal cable 6. backplane power cable (2)
7. SAS cable A0/B0 8. USB cable
9. control panel cable 10. right ear control panel flex cable
11. hard-drive backplane 12. hard-drive backplane connector (12)
1. Replace the hard-drive backplane. See Installing the hard-drive backplane .
2. Follow the procedure listed in After working inside your system .

Installing the hard-drive backplane

1. Ensure that you read the Safety instructions .

Next steps

Page 123 of the Dell XC730xd user manual — Removing the optional hard-drive backplane (back)
Page 123 · click to enlarge
Page 123
2. Follow the procedure listed in Before working inside your system .

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

Steps 1. Use the hooks on the chassis as guides to align the hard-drive backplane.

2. Lower the hard-drive backplane until the release tabs snap into place.
3. Connect the SAS/SATA/SSD data, signal, and power cable(s) to the backplane.
1. Replace the cooling-fan assembly.
2. Replace the cooling shroud.
3. Install the hard drives in their original locations.
4. Follow the procedure listed in After working inside your system .

Removing the optional hard-drive backplane (back)

1. Ensure that you read the Safety instructions .
2. Follow the procedure listed in Before working inside your system.
3. Remove both hard drives.

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

Steps 1. Disconnect all the cables from the backplane.

2. Lift the release pin and slide the backplane toward the front of the chassis.
3. Lift the backplane to remove it from the chassis.

Next steps

Page 124 of the Dell XC730xd user manual — Removing the optional hard-drive backplane (back)
Page 124 · click to enlarge
Page 124
Dell XC730xd — Removing the optional hard-drive backplane (back) diagram (page 124)
Fig. 70 · Removing the optional hard-drive backplane (back)

Figure 58. Removing and installing the optional 2.5 inch (x2) hard-drive backplane

1. SAS cable 2. release pin
3. hard-drive connector (2) 4. power cable
5. backplane signal cable
Dell XC730xd — Removing the optional hard-drive backplane (back) diagram (page 124)
Fig. 71 · Removing the optional hard-drive backplane (back)

http://www.Dell.com/XCSeries/XC730xd/MidBP

Related video

Page 125 of the Dell XC730xd user manual — Removing the control panel
Page 125 · click to enlarge
Page 125

Removing the control panel

1. Ensure that you read the Safety instructions .
2. Follow the procedure listed in Before working inside your system .
3. Keep the T15 Torx screwdriver handy.

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

Steps 1. Disconnect the control panel cable from the hard-drive backplane by pulling on the plastic pull tab.

2. Remove the screws that secure the control panel to the chassis.
3. Fold the plastic pull tab close to the connector.
4. Pull out the control panel cable as you guide the connector and the plastic pull tab through the channel on the chassis.
Page 126 of the Dell XC730xd user manual — Installing the control panel
Page 126 · click to enlarge
Page 126
Dell XC730xd — Installing the control panel diagram (page 126)
Fig. 72 · Installing the control panel

Figure 59. Removing and installing the control panel

1. screw (3) 2. control panel
3. hard-drive backplane 4. connector
5. plastic pull tab
1. Replace the control panel. See Installing the control panel .
2. Follow the procedure listed in After working inside your system .
Dell XC730xd — Installing the control panel diagram (page 126)
Fig. 73 · Installing the control panel

http://www.Dell.com/XCSeries/XC730xd/CP

Installing the control panel

1. Ensure that you read the Safety instructions .
2. Keep the #2 Phillips screwdriver handy.

Next steps · Related video

Page 127 of the Dell XC730xd user manual — Removing the I/O panel
Page 127 · click to enlarge
Page 127

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

Steps 1. Replace the blank information tag in the new control panel with the information tag retained from the old control panel.

2. To install the information tag, push the information tag into the control-panel slot.
3. Connect all the applicable cables to the control panel.
4. Slide the control panel into the slot in the chassis and secure the module with the screw.

Follow the procedure listed in After working inside your system.

Removing the I/O panel

1. Ensure that you read the Safety instructions .
2. Follow the procedure listed in Before working inside your system .
3. Keep the T15 Torx screwdriver handy.

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

Steps 1. Rotate the locking tab on the I/O cable connector clockwise 90 degrees to release the lock.

For more information on the locking tab, see Removing the hard-drive backplane.

2. Disconnect the I/O cable from the backplane.
3. Remove the screws securing the I/O panel to the chassis.
4. Pull out the I/O panel cable through the channel on the chassis.

Next steps

Page 128 of the Dell XC730xd user manual — Installing the I/O panel
Page 128 · click to enlarge
Page 128
Dell XC730xd — Installing the I/O panel diagram (page 128)
Fig. 74 · Installing the I/O panel

Figure 60. Removing and installing the I/O panel

1. I/O panel cable 2. hard-drive backplane
3. screw (3) 4. I/O panel
5. chassis
1. Replace the I/O panel. See Installing the I/O panel .
2. Follow the procedure listed in After working inside your system .

Installing the I/O panel

1. Ensure that you read the Safety instructions .
2. Follow the procedure listed in Before working inside your system .
3. Keep the T15 Torx screwdriver handy.

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

Next steps

Page 129 of the Dell XC730xd user manual — Removing the hard-drive backplane from the hard-drive tray
Page 129 · click to enlarge
Page 129

Steps 1. Fold the PPID label around the cable.

2. Push the cable until the cable passes completely through the channel.
3. If locked, rotate the locking tab on the I/O cable connector clockwise 90 degrees to release the lock.
4. Connect the I/O panel cable to the connector on the hard-drive backplane.
5. Rotate the locking tab on the I/O cable connector counter clockwise 90 degrees to secure the lock.
6. Tighten the screws to secure the control panel to the chassis.

Follow the procedure listed in After working inside your system.

Removing the hard-drive backplane from the hard-drive tray

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

1. Ensure that you read the Safety instructions .
2. Follow the procedure listed in Before working inside your system .
3. Disconnect all the cables from the backplane.
4. Remove the hard-drive carriers.
5. Remove the hard-drive tray from the system.

Press the release tabs and lift the backplane out of the hard-drive tray.

Next steps · Steps

Page 130 of the Dell XC730xd user manual — Installing the hard-drive backplane in the hard-drive tray
Page 130 · click to enlarge
Page 130
Dell XC730xd — Installing the hard-drive backplane in the hard-drive tray diagram (page 130)
Fig. 75 · Installing the hard-drive backplane in the hard-driv…

Figure 61. Removing and installing the 3.5 inch (x4) hard-drive backplane

1. release tab (2) 2. hard-drive indicators
3. hard-drive connector (4) 4. guide pin
5. hard-drive backplane

Installing the hard-drive backplane in the hard-drive tray

1. Ensure that you read the Safety instructions .
2. Follow the procedure listed in Before working inside your system .

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

Steps 1. Align the hard-drive backplane with the guide pin on the chassis and lower the hard-drive backplane on the chassis until it is firmly seated.

2. Install the hard-drives carriers in to the hard-drive tray.
3. Install the hard-drive tray in to the chassis.
4. Follow the procedure listed in After working inside your system .

About this task · Related video

Page 131 of the Dell XC730xd user manual — Installing the hard-drive backplane in the hard-drive tray
Page 131 · click to enlarge
Page 131
Dell XC730xd — Installing the hard-drive backplane in the hard-drive tray diagram (page 131)
Fig. 76 · Installing the hard-drive backplane in the hard-driv…

http://www.Dell.com/XCSeries/XC730xd/MidTray

Page 132 of the Dell XC730xd user manual — Troubleshooting a USB device
Page 132 · click to enlarge
Page 132

5 Troubleshooting your system

Safety first—for you and your system

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

Troubleshooting system startup failure

You must boot to the same boot mode in which you installed the operating system.

For all other startup issues, note the system messages that appear on the screen.

Troubleshooting external connections

Ensure that all external cables are securely attached to the external connectors on your system before troubleshooting any external devices.

Troubleshooting the video subsystem

1. Check the system and power connections to the monitor.
2. Check the video interface cabling from the system to the monitor.
3. Run the appropriate diagnostic test.

If the tests run successfully, the problem is not related to video hardware.

If the tests fail, see Getting Help.

Troubleshooting a USB device

About this task Use the following steps to troubleshoot a USB keyboard/mouse. For other USB devices, go to step 7. Steps 1. Disconnect the keyboard and mouse cables from the system and reconnect them.

2. If the problem persists, connect the keyboard/mouse to the USB ports on the opposite side of the system.
3. If the problem is resolved, restart the system, enter the System Setup, and check if the nonfunctioning USB ports are enabled.
Page 133 of the Dell XC730xd user manual — Troubleshooting iDRAC Direct (USB XML configuration)
Page 133 · click to enlarge
Page 133

Check if USB 3.0 is enabled in System Setup. If enabled, disable it and see if the issue is resolved (older operating systems may not support USB 3.0).

4. In the IDRAC Settings Utility , ensure the USB Management Port Mode is configured as Automatic or Standard OS Use .
5. Replace the keyboard/mouse with a working keyboard/mouse.

If the problem is not resolved, proceed to the next step to begin troubleshooting other USB devices attached to the system.

6. Power down all attached USB devices and disconnect them from the system.
7. Restart the system and, if your keyboard is functioning, enter the System Setup.
8. Verify that all USB ports are enabled on the Integrated Devices screen, in the System Setup options.
9. Check if USB 3.0 is enabled in System Setup. If it is enabled, disable it and restart your system.

If your keyboard is not functioning, you can also use remote access.

10. If the system is not accessible, reset the NVRAM_CLR jumper inside your system and restore the BIOS to the default settings.
11. In the IDRAC Settings Utility , ensure the USB Management Port Mode is configured as Automatic or Standard OS Use .
12. Reconnect and power on each USB device one at a time.
13. If a USB device causes the same problem, power down the device, replace the USB cable with a known good cable, and power up the device.

If all troubleshooting fails, see Getting Help.

Troubleshooting iDRAC Direct (USB XML configuration)

For information on USB storage device and server configuration, see the Integrated Dell Remote Access Controller User's Guide at dell.com/esmanuals

1. Ensure your USB storage device is connect to the front USB Management Port, identified by

icon.

2. Ensure your USB storage device is configured with an NTFS or a FAT32 file system with only one partition.
3. Verify that the USB storage device is configured correctly. For more information on configuring the USB storage device, see the Integrated Dell Remote Access Controller User's Guide at dell.com/ esmanuals .
4. In the IDRAC Settings Utility , ensure the USB Management Port Mode is configured as Automatic or iDRAC Direct Only .
5. Ensure the iDRAC Managed: USB XML Configuration option is either Enabled or Enabled only when the server has default credential settings .
6. Remove and re-insert the USB storage device.
7. If import operation does not work, try with a different USB storage device.

Next steps If all troubleshooting fails, see Getting help.

Next steps · Steps

Page 134 of the Dell XC730xd user manual — Troubleshooting a NIC
Page 134 · click to enlarge
Page 134

Troubleshooting iDRAC Direct (laptop connection)

For information on USB laptop connection and server configuration, see the Integrated Dell Remote Access Controller User's Guide at dell.com/esmanuals

1. Ensure your laptop is connected to the front USB Management Port, identified by

icon with a USB Type A/A cable.

2. In the IDRAC Settings Utility , ensure the USB Management Port Mode is configured as Automatic or iDRAC Direct Only .
3. If the laptop is running the Windows operating system, ensure the iDRAC Virtual USB NIC device driver is installed.
4. If the driver is installed, ensure you are not connected to any network through WiFi or cabled ethernet as iDRAC Direct uses a non-routable address.

Next steps If all troubleshooting fails, see Getting help.

Troubleshooting a serial I/O device

Steps 1. Turn off the system and any peripheral devices connected to the serial port.

2. Swap the serial interface cable with a working cable, and turn on the system and the serial device.

If the problem is resolved, replace the interface cable with a known good cable.

3. Turn off the system and the serial device, and swap the serial device with a comparable device.
4. Turn on the system and the serial device.

If the problem persists, see Getting Help.

Troubleshooting a NIC

Steps 1. Run the appropriate diagnostic test. See Using system diagnostics for available diagnostic tests.

2. Restart the system and check for any system messages pertaining to the NIC controller.
  • 3. Check the appropriate indicator on the NIC connector:
  • If the link indicator does not light, check all cable connections.
  • If the activity indicator does not light, the network driver files might be damaged or missing.

Remove and reinstall the drivers if applicable. See the NIC documentation.

  • If applicable, change the autonegotiation setting.
  • Use another connector on the switch or hub.
4. Ensure that the appropriate drivers are installed and the protocols are bound. See the NIC documentation.
5. Enter the System Setup and confirm that the NIC ports are enabled on the Integrated Devices screen.
6. Ensure that the NICs, hubs, and switches on the network are all set to the same data transmission speed and duplex. See the documentation for each network device.

Steps · Next steps

Page 135 of the Dell XC730xd user manual — Troubleshooting a wet system
Page 135 · click to enlarge
Page 135
7. Ensure that all network cables are of the proper type and do not exceed the maximum length.

If all troubleshooting fails, see Getting Help.

Troubleshooting a wet system

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

Steps 1. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.

2. Remove the system cover.
3. Remove the following components from the system:
  • hard drives
  • hard-drive backplane
  • USB memory key
  • hard-drive tray
  • cooling shroud
  • expansion-card risers (if present)
  • expansion cards
  • power supply unit(s)
  • cooling-fan assembly (if present)
  • cooling fans
  • processor(s) and heat sink(s)
  • memory modules 4. Let the system dry thoroughly for at least 24 hours.
5. Reinstall the components you removed in step 3.
6. Install the system cover.
7. Turn on the system and attached peripherals.

If the system does not start properly, see Getting Help.

8. If the system starts properly, shut down the system, and reinstall all the expansion cards that you removed.
9. Run the appropriate diagnostic test. For more information, see Using system diagnostics .

If the tests fail, see Getting Help.

Next steps · Next steps

Page 136 of the Dell XC730xd user manual — Troubleshooting the system battery
Page 136 · click to enlarge
Page 136

Troubleshooting a damaged system

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

Steps 1. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.

2. Remove the system cover.
3. Ensure that the following components are properly installed:
  • Cooling shroud
  • Expansion-card risers (if present)
  • Expansion cards
  • Power supply(s)
  • Cooling-fan assembly (if present)
  • Cooling fans
  • Processor(s) and heat sink(s)
  • Memory modules
  • Hard-drive carriers
  • Hard-drive backplane 4. Ensure that all cables are properly connected.
5. Install the system cover.
6. Run the appropriate diagnostic test. For more information, see Using system diagnostics .

If the tests fail, see Getting Help.

Troubleshooting the system battery

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

Next steps

Page 137 of the Dell XC730xd user manual — Power supply unit problems
Page 137 · click to enlarge
Page 137

Steps 1. Re-enter the time and date in the System Setup.

2. Turn off the system and disconnect it from the electrical outlet for at least one hour.
3. Reconnect the system to the electrical outlet and turn on the system.
4. Enter the System Setup.

If the date and time are not correct in the System Setup, check the SEL for system battery messages.

Next steps If the problem persists, see Getting Help.

Troubleshooting power supply units

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

Power source problems

1. Press the power button to ensure that your system is turned on. If the power indicator does not light up when the power button is pressed, press the power-on button firmly.
2. Plug in another working device to ensure that the system board is not faulty.
3. Ensure that no loose connections exist.

For example, loose power cables.

4. Ensure that the power source meets applicable standards.
5. Ensure that there are no short circuits.
6. Have a qualified electrician check the line voltage to ensure that it meets the required specifications.

Power supply unit problems

1. Ensure that no loose connections exist.

For example, loose power cables.

2. Ensure that the power supply handle/LED indicates that the power supply is working properly.
3. If you have recently upgraded your system, ensure that the power supply unit has enough power to support the new system.
4. If you have a redundant power supply configuration, ensure that both the power supply units are of the same type and wattage.

If the LED You may have to upgrade to a higher wattage power supply unit.

5. Ensure that you use only power supply units with the Extended Power Performance (EPP) label on the back.
6. Reseat the power supply unit.

If the problem persists, see Getting Help.

Page 138 of the Dell XC730xd user manual — Troubleshooting cooling fans
Page 138 · click to enlarge
Page 138

Troubleshooting cooling problems

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

Ensure that the following conditions exist:

  • System cover, cooling shroud, EMI filler panel, or back-filler bracket is not removed.
  • Ambient temperature is not too high.
  • External airflow is not obstructed.
  • A cooling fan is not removed or has not failed.
  • The expansion card installation guidelines have been followed.

Additional cooling can be added by one of the following methods:

From the iDRAC Web GUI:

1. Click Hardware → Fans → Setup .
2. From the Fan Speed Offset drop-down list, select the cooling level needed or set the minimum fan speed to a custom value.

From F2 System Setup

1. Select iDRAC Settings → Thermal , and set a higher fan speed from the fan speed offset or minimum fan speed.
1. Run the command racadm help system.thermalsettings

For more information, see the Integrated Dell Remote Access Controller User's Guide at dell.com/ esmmanuals.

Troubleshooting cooling fans

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

Steps 1. Remove the system cover.

2. Reseat the fan or the fan's power cable.

From RACADM commands

Page 139 of the Dell XC730xd user manual — Troubleshooting system memory
Page 139 · click to enlarge
Page 139
3. Install the system cover.
4. Restart your system.,

If the problem persists, see Getting Help.

Troubleshooting system memory

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

Steps 1. If the system is operational, run the appropriate diagnostic test. See Using system diagnostics for available diagnostic tests.

If diagnostics indicate a fault, follow the corrective actions provided by the diagnostic program.

2. If the system is not operational, turn off the system and attached peripherals, and unplug the system from the power source. Wait at least 10 seconds and then reconnect the system to the power source.
3. Turn on the system and attached peripherals and note the messages on the screen.

If an error message is displayed indicating a fault with a specific memory module, go to step 12.

4. Enter the System Setup and check the system memory setting. Make any changes to the memory settings, if needed.

If the memory settings match the installed memory but the problem still persists, go to step 12.

5. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
6. Remove the system cover.
7. Check the memory channels and ensure that they are populated correctly.
8. Reseat the memory modules in their sockets.
9. Install the system.
10. Enter the System Setup and check the system memory setting.

If the problem is not resolved, proceed with the next step.

11. Remove the system cover.
12. If a diagnostic test or error message indicates a specific memory module as faulty, swap or replace the module with a known good memory module.
13. To troubleshoot an unspecified faulty memory module, replace the memory module in the first DIMM socket with a module of the same type and capacity.

If an error message is displayed on the screen, this may indicate a problem with the installed DIMM type(s), incorrect DIMM installation, or defective DIMM(s). Follow the on-screen instructions to resolve the problem.

14. Install the system cover.
15. As the system boots, observe any error message that is displayed and the diagnostic indicators on the front of the system.

Next steps

Page 140 of the Dell XC730xd user manual — Troubleshooting a hard drive
Page 140 · click to enlarge
Page 140
16. If the memory problem persists, repeat step 12 through step 15 for each memory module installed.

If the problem persists after all memory modules have been checked, see Getting Help.

Troubleshooting an SD card

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

Steps 1. Enter the System Setup and ensure that the Internal SD Card Port is enabled.

2. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.
3. Remove the system cover.
4. Replace the failed SD card with a new SD card.
5. Install the system cover.
6. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.
7. Enter the System Setup and ensure that the Internal SD Card Port and Internal SD Card Redundancy mode is set to the required mode.

Verify that correct SD slot is set as Primary SD Card.

8. Check if the SD card is functioning properly.
9. If the Internal SD Card Redundancy option is set to Enabled at the time of the SD card failure, the system prompts you to perform a rebuild.

Troubleshooting a hard drive

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

Next steps

Page 141 of the Dell XC730xd user manual — Troubleshooting a storage controller
Page 141 · click to enlarge
Page 141

Steps 1. Run the appropriate diagnostic test. For more information, see Using system diagnostics.

Depending on the results of the diagnostics test, proceed as needed through the following steps.

2. Ensure that the required device drivers for your controller card are installed and are configured correctly. See the operating system documentation for more information.
3. Reboot the system and enter the System Setup.
4. Verify that the controller is enabled and the drives are displayed in the System Setup.

Next steps If the problem persists, try troubleshooting the expansion cards or see Getting Help.

Troubleshooting a storage controller

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

1. Run the appropriate diagnostic test. For more information, see Using system diagnostics .
2. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
3. Remove the system cover.
4. Verify that the installed expansion cards are compliant with the expansion card installation guidelines.
5. Ensure that each expansion card is firmly seated in its connector.
6. Install the system cover.
7. Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.
8. If the problem is not resolved, turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
9. Remove the system cover.
10. Remove all expansion cards installed in the system.
11. Install the system cover.
12. Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.
13. Run the appropriate diagnostic test. For more information, see . If the tests fail, see Getting Help .
14. For each expansion card you removed in step 10, perform the following steps:

a. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.

b. Remove the system cover.

c. Reinstall one of the expansion cards.

d. Install the system cover.

e. Run the appropriate diagnostic test. For more information, see Using system diagnostics.

If the tests fail, see Getting Help.

Page 142 of the Dell XC730xd user manual — Troubleshooting processors
Page 142 · click to enlarge
Page 142

Troubleshooting expansion cards

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

Steps 1. Run the appropriate diagnostic test. For more information, see Using system diagnostics.

2. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
3. Remove the system cover.
4. Ensure that each expansion card is firmly seated in its connector.
5. Install the system cover.
6. If the problem is not resolved, turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
7. Remove the system cover.
8. Remove all expansion cards installed in the system.
9. Install the system cover.

If the tests fail, see Getting Help.

10. For each expansion card you removed in step 8, perform the following steps:

a. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet. b. Remove the system cover. c. Reinstall one of the expansion cards. d. Install the system cover. e. Run the appropriate diagnostic test. For more information, see Using system diagnostics.

If the problem persists, see Getting Help.

Troubleshooting processors

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

Steps 1. Run the appropriate diagnostics test. See Using system diagnostics for available diagnostic tests.

2. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
3. Remove the system cover.

Next steps

Page 143 of the Dell XC730xd user manual — Alert messages
Page 143 · click to enlarge
Page 143
4. Ensure that the processor and heat sink are properly installed.
5. Install the system cover.
6. Run the appropriate diagnostic test. For more information, see Using system diagnostics .

If the problem persists, see Getting Help.

System messages

For a list of event and error messages generated by the system firmware and agents that monitor system components, see the Dell Event and Error Messages Reference Guide at dell.com/esmmanuals

Warning messages

A warning message alerts you to a possible problem and prompts you to respond before the system continues a task. For example, before you format a hard drive, a message warns you that you may lose all data on the hard drive. Warning messages usually interrupt the task and require you to respond by typing y (yes) or n (no).

Diagnostic messages

The system diagnostic utilities may issue messages if you run diagnostic tests on your system. See Using system diagnostics for more information about system diagnostics.

Alert messages

The systems management software generates alert messages for your system. Alert messages include information, status, warning, and failure messages for drive, temperature, fan, and power conditions. For more information, see the systems management software documentation.

Next steps

Page 144 of the Dell XC730xd user manual — Running the Embedded System Diagnostics from the Dell Lifecycle Controller
Page 144 · click to enlarge
Page 144

6 Using system diagnostics

If you experience a problem with your system, run the system diagnostics before contacting Dell for technical assistance. The purpose of running system diagnostics is to test your system hardware without requiring additional equipment or risking data loss. If you are unable to fix the problem yourself, service and support personnel can use the diagnostics results to help you solve the problem.

Dell Embedded System Diagnostics

The embedded system diagnostics provides a set of options for particular device groups or devices allowing you to:

  • Run tests automatically or in an interactive mode
  • Repeat tests
  • Display or save test results
  • Run thorough tests to introduce additional test options to provide extra information about the failed device(s)
  • View status messages that inform you if tests are completed successfully
  • View error messages that inform you of problems encountered during testing

When to use the Embedded System Diagnostics

If a major component or device in the system does not operate properly, running the embedded system diagnostics may indicate component failure.

Running the Embedded System Diagnostics from Boot Manager

1. As the system boots, press F11.
2. Use the up and down arrow keys to select System Utilities → Launch Diagnostics .

The ePSA Pre-boot System Assessment window is displayed, listing all devices detected in the system. The diagnostics starts running the tests on all the detected devices.

Running the Embedded System Diagnostics from the Dell Lifecycle Controller

1. As the system boots, press F11.
2. Select Hardware Diagnostics → Run Hardware Diagnostics .

The ePSA Pre-boot System Assessment window is displayed, listing all devices detected in the system. The diagnostics starts running the tests on all the detected devices.

Page 145 of the Dell XC730xd user manual — System diagnostic controls
Page 145 · click to enlarge
Page 145

System diagnostic controls

Configuration Displays the configuration and status information of all detected devices.

Results Displays the results of all tests that are run.

System health Provides the current overview of the system performance.

Event log Displays a time-stamped log of the results of all tests run on the system. This is displayed if at least one event description is recorded.

For information about embedded system diagnostics, see the ePSA Diagnostics Guide (Notebooks, Desktops and Servers) at dell.com/support/home

Menu Description

Page 146 of the Dell XC730xd user manual — NVRAM_CLR
Page 146 · click to enlarge
Page 146

7 Jumpers and connectors

System board jumper settings

Table 30. System board jumper settings

PWRD_EN

The password reset feature is enabled (pins 2–4). BIOS local access is unlocked at the next AC power cycle.

The password reset feature is disabled (pins 4–6).

NVRAM_CLR

The configuration settings are retained at the next system boot (pins 3–5).

The configuration settings are cleared at system boot (pins 1–3).

Jumper Setting Description

Page 147 of the Dell XC730xd user manual — System board connectors
Page 147 · click to enlarge
Page 147

System board connectors

Dell XC730xd — System board connectors diagram (page 147)
Fig. 77 · System board connectors

Figure 62. System board jumpers and connectors

1 J_BP_SIG1 Backplane signal connector 1

2 J_PS_2 PSU 2 connector

3 J_BP_SIG0 Backplane signal connector 0

4 J_BP0 Backplane power connector 0

5 J_SATA_CD Optical drive SATA connector, SATADOM connector

6 J_SATA_TBU Tape backup unit SATA connector

7 J_TBU SATADOM power connector

8 J_PS_1 PSU 1 connector

9 J_IDSDM Internal dual SD module connector

Item Connector Description

Page 148 of the Dell XC730xd user manual — System board connectors
Page 148 · click to enlarge
Page 148

10 J_NDC Network daughter card connector

11 J_USB USB connector

12 J_VIDEO_REAR Video connector

13 J_COM1 Serial connector

14 J_IDRAC_RJ45 iDRAC 8 connector

15 J_CYC System identification connector

16 CYC_ID System identification button

17 J_TPM_MODULE Trusted Platform Module connector

18 J_RISER_2AX Riser 3 connector

19 J_RISER_1AX Riser 1 connector

20 J_RISER_2BX Riser 2 connector

21 J_RISER_1BX Riser 1 connector

22 J_RISER_3AX Riser 3 connector

23 J_QS Quick Sync bezel connector

24 J_RISER_3BX Riser 3 connector

25 J_SATA_B Internal SAS connector

26 J_STORAGE Mini PERC connector

27 J_USB_INT Internal USB connector

28 J_SATA_A Internal SAS connector

29 BAT Battery connector

30 CPU 2 Processor socket 2

31 J_BP3 Backplane power connector 3

32 B10, B6, B2, B9, B5, B1 Memory module sockets

33 J_BP_SIG2 Backplane signal connector 2

34 J_FAN2U_6 Cooling fan connector

35 J_FAN2U_5 Cooling fan connector

36 J_BP2 Backplane power connector 2

37 B3, B7, B11, B4, B8, B12 Memory module sockets

38 J_FAN2U_4 Cooling fan connector

39 A10, A6, A2, A9, A5, A1 Memory module sockets

40 J_FAN2U_3 Cooling fan connector

41 J_BP1 Backplane power connector

42 J_FAN2U_2 Cooling fan connector

Item Connector Description

Page 149 of the Dell XC730xd user manual — Disabling a forgotten password
Page 149 · click to enlarge
Page 149

43 A3, A7, A11, A4, A8, A12 Memory module sockets

44 J_FAN2U_1 Cooling fan connector

45 J_CTRL_PNL Control panel signal connector

46 CPU 1 Processor 1

47 J_FP_USB Front-panel USB connector

Disabling a forgotten password

The system's software security features include a system password and a setup password. The password jumper enables these password features or disables them and clears any password(s) currently in use.

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

Steps 1. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.

2. Open the system.
3. Move the jumper on the system-board jumper from pins 4 and 6 to pins 2 and 4.
4. Close the system.

The existing passwords are not disabled (erased) until the system boots with the jumper on pins 2 and 4. However, before you assign a new system and/or setup password, you must move the jumper back to pins 4 and 6.

5. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.
6. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.
7. Open the system.
8. Move the jumper on the system-board jumper from pins 2 and 4 to pins 4 and 6.
9. Close the system.
10. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.
11. Assign a new system and/or setup password.

Item Connector Description

Page 150 of the Dell XC730xd user manual — 8 Technical specifications
Page 150 · click to enlarge
Page 150

8 Technical specifications

Processor type Two Intel Xeon processor E5-2600 v3 product family

AC power supply (per power supply)

Wattage 495 W, 750 W, or 1100 W

1908 BTU/hr maximum (495 W power supply)

2891 BTU/hr maximum (750 W power supply)

2843 BTU/hr maximum (750 W Titanium power supply)

4100 BTU/hr maximum (1100 W power supply)

4416 BTU/hr maximum (DC1100W power supply)

2891 BTU/hr maximum (750 W mixed mode power supply)

100–240 V AC, autoranging, 50/60 Hz

200–240 V AC, autoranging, 50/60 Hz, for 750 W Titanium power supply

Bus type PCI Express Generation 3

Expansion cards For a list of supported expansion cards, see Expansion cards and expansion-card risers

Expansion slots using riser card:

Riser 1 (Slot 1) One half-height, low-profile x8 link

(Slot 2) One half-height, low-profile x8 link

(Slot 3) One half-height, low-profile x8 link

Riser 2 (Slot 4) One full-height, full-length x16 link

Show 5 more labels / short text on this page
Processor · Power · Heat dissipation · Voltage · Expansion Bus
Page 151 of the Dell XC730xd user manual — Technical specifications
Page 151 · click to enlarge
Page 151

(Slot 5) One full-height, full-length x8 link

Riser 3 (default) (Slot 6) One full-height, full-length x8 link

Architecture 1333 MT/s, 1600 MT/s, 1866 MT/s or 2133 MT/s DDR4 registered, load-reduced Error Correcting Code (ECC) DIMMs

Support for advanced ECC or memory optimized operation

Memory module sockets Twenty-four 288-pin

LRDIMMs 32 GB quad-ranked

RDIMMs 8 GB or 16 GB dual-ranked

Minimum RAM 64 GB with a dual processor

Maximum RAM Up to 768 GB with a dual processor

Up to 384 GB with a single processor

Twelve hard-drive systems Up to twelve 3.5 inch drives

Twenty-four hard-drive systems Up to twenty-four drives

NIC Four 1 Gbps, two 1 Gbps plus two 10 Gbps, or four 10 Gbps

Serial 9-pin, DTE, 16550-compatible

USB Two 4-pin, USB 3.0-compliant

External vFlash card One flash memory card slot with iDRAC8 Enterprise card

Show 8 more labels / short text on this page
Expansion Bus · Memory · Memory module capacities · Drives · Hard drives · Connectors · Back · Video 15-pin VGA
Page 152 of the Dell XC730xd user manual — Technical specifications
Page 152 · click to enlarge
Page 152

USB One 4-pin, USB 2.0-compliant

One USB management port/iDRAC Direct

USB One 4-pin, USB 3.0-compliant

Internal Dual SD Module Two flash memory card slots with the internal SD module

Video type Matrox G200eR2

Video memory 16 MB

Height 8.73 cm (3.44 inch)

Width 48.2 cm (18.98 inch)

Depth 75.58 cm (29.75 inch)

  • Maximum configuration weight
  • 30.4 kg (67.02 lb) (2.5 inch hard drive systems)
  • 36.5 kg (80.47 lb) (3.5 inch hard drive systems)
  • Empty weight
  • 19 kg (41.89 lb) (2.5 inch hard drive systems)
  • 23.2 kg (51.15 lb) (3.5 inch hard drive systems)

Storage –40°C to 65°C (–40°F to 149°F)

Continuous operation (for altitude less than 950 m or 3117 ft)

10°C to 35°C (50°F to 95°F) with no direct sunlight on the equipment.

Fresh air For information on fresh air, see Expanded Operating Temperature section.

Maximum temperature gradient (operating and storage)

Show 10 more labels / short text on this page
Connectors · Front · Video 15-pin VGA · Internal · Video · Physical · Environmental specifications · Temperature · 20°C/h (36°F/h) · Relative humidity
Page 153 of the Dell XC730xd user manual — Technical specifications
Page 153 · click to enlarge
Page 153

Storage 5% to 95% RH with 33°C (91°F) maximumdew point. Atmosphere must be non-condensing at all times.

Operating 10% to 80% Relative Humidity with 29°C (84.2°F)maximum dew point.

Operating 0.26 Grms at 5 Hz to 350 Hz(all operation orientations).

Storage 1.88 Grms at 10 Hz to 500Hz for 15 min (all six sides tested).

Operating Six consecutively run shock pulses in the positive and negative x, y, and z axes of 40 G for up to 2.3 ms.

Storage Six consecutively run shock pulses in the positive and negative x, y, and z axes (one pulse on each side of the system) of 71 G for up to 2 ms.

Operating 3048 m (10,000 ft).

Storage 12,000 m (39,370 ft).

Up to 35 °C (95 °F) Maximum temperature is reduced by 1°C/300m (1°F/547 ft) above 950 m (3,117 ft).

35 °C to 40 °C (95 °F to 104 °F) Maximum temperature is reduced by 1°C/175m (1°F/319 ft) above 950 m (3,117 ft).

40 °C to 45 °C (104 °F to 113 °F) Maximum temperature is reduced by 1°C/125m (1°F/228 ft) above 950 m (3,117 ft).

NOTE: This section defines the limits to help avoid IT equipment damage and/or failure from particulates and gaseous contamination. If it is determined that levels of particulates or gaseous pollution are beyond the limits specified below and are the reason for the damage and/or failures to your equipment, it may be necessary for you tore-mediate the environmental conditions that are causing the damage and/or failures. Re-mediation of environmental conditions is the responsibility of the customer.

Air filtration Data center air filtration as defined by ISO Class 8 per ISO 14644-1 with a 95% upper confidence limit.

Show 6 more labels / short text on this page
Physical · Maximum vibration · Maximum shock · Maximum altitude · Operating temperature de-rating · Particulate contamination
Page 154 of the Dell XC730xd user manual — Technical specifications
Page 154 · click to enlarge
Page 154

Air must be free of conductive dust, zinc whiskers, or other conductive particles.

  • Air must be free of corrosive dust.
  • Residual dust present in the air must have a deliquescent pointless than 60% relative humidity

Copper coupon corrosion rate

Silver coupon corrosion rate

Continuous operation 5°C to 40°C at 5% to 85% RH with 29°C dew point.

For temperatures between 35°C and 40°C, de- rate maximum allowable temperature by 1°C per 175 m above 950 m (1°F per 319 ft).

< 1% of annual operating hours –5°C to 45°C at 5% to 90% RH with 29°C dew point.

Show 5 more labels / short text on this page
Physical · Conductive dust · Corrosive dust · Gaseous contamination · Expanded operating temperature
Page 155 of the Dell XC730xd user manual — Technical specifications
Page 155 · click to enlarge
Page 155

For temperatures between 40°C and 45°C, de- rate maximum allowable temperature by 1°C per 125 m above 950 m (1°F per 228 ft).

  • Expanded Operating Temperature Restrictions
  • Do not perform a cold startup below 5°C.
  • The operating temperature specified is for a maximum altitude of 3050 m (10,000 ft).
  • 160 W (10 core) processor is not supported.
  • Tape Backup Unit (TBU) is not supported.
  • Redundant power supplies are required.
  • Non Dell qualified peripheral cards and/or peripheral cards greater than 25 W are not supported.
  • PCIe SSD and GPU is not supported.
  • Maximum 120 W processor supported on 3.5 inch hard drive chassis.
  • Maximum 145 W processor supported on 2.5 inch hard drive chassis.
  • Only SSDs are allowed in the hard drive slots at the back of the 3.5 inch hard drive chassis.

Physical

Page 156 of the Dell XC730xd user manual — Quick Resource Locator
Page 156 · click to enlarge
Page 156

9 Getting help

Contacting Dell

Dell provides several online and telephone-based support and service options. If you do not have an active Internet connection, you can find contact information on your purchase invoice, packing slip, bill, or Dell product catalog. Availability varies by country and product, and some services may not be available in your area. To contact Dell for sales, technical support, or customer-service issues:

2. Select your country from the drop-down menu on the bottom right corner of the page.
3. For customized support:

a. Enter your system Service Tag in the Enter your Service Tag field. b. Click Submit.

The support page that lists the various support categories is displayed.

4. For general support:

a. Select your product category. b. Select your product segment. c. Select your product.

The support page that lists the various support categories is displayed.

Locating your system Service Tag

Your system is identified by a unique Express Service Code and Service Tag number. The Express Service Code and Service Tag are found on the front of the system by pulling out the information tag. Alternatively, the information may be on a sticker on the chassis of the system. This information is used by Dell to route support calls to the appropriate personnel.

Documentation feedback

If you have feedback for this document, write to documentation_feedback@dell.com. Alternatively, you can click on the Feedback link in any of the Dell documentation pages, fill out the form, and click Submit to send your feedback.

Quick Resource Locator

Use the Quick Resource Locator (QRL) to get immediate access to system information and how-to videos. This can be done by visiting dell.com/QRL or by using your smartphone or tablet and a model specific Quick Resource (QR) code located on your Dell system. To try out the QR code, scan the following image.

Page 157 of the Dell XC730xd user manual — Getting help
Page 157 · click to enlarge
Page 157

Figure 63. Quick Resource Locator

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Dell XC730xd

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Dell XC730xd

Be the first to ask — other owners or our team will answer.

Original document

Dell XC730xd manual PDF

157 pages·10.3 MB·Life Jacket·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…