© 2013 Dell Inc.
Trademarks used in this text: Dell™, the Dell logo, Dell Boomi™, Dell Precision™ , OptiPlex™, Latitude™, PowerEdge™, PowerVault™, PowerConnect™, OpenManage™, EqualLogic™, Compellent™, KACE™, FlexAddress™, Force10™ and Vostro™ are trademarks of Dell Inc. Intel®, Pentium®, Xeon®, Core® and Celeron® are registered trademarks of Intel Corporation in the U.S. and other countries. AMD® is a registered trademark and AMD Opteron™, AMD Phenom™ and AMD Sempron™ are trademarks of Advanced Micro Devices, Inc. Microsoft®, Windows®, Windows Server®, Internet Explorer®, MS-DOS®, Windows Vista® and Active Directory® are either trademarks or registered trademarks of Microsoft Corporation in the United States and/or other countries. Red Hat® and Red Hat® Enterprise Linux® are registered trademarks of Red Hat, Inc. in the United States and/or other countries. Novell® and SUSE® are registered trademarks of Novell Inc. in the United States and other countries. Oracle® is a registered trademark of Oracle Corporation and/or its affiliates. Citrix®, Xen®, XenServer® and XenMotion® are either registered trademarks or trademarks of Citrix Systems, Inc. in the United States and/or other countries. VMware®, vMotion®, vCenter®, vCenter SRM™ and vSphere® are registered trademarks or trademarks of VMware, Inc. in the United States or other countries. IBM® is a registered trademark of International Business Machines Corporation.
Rev. A00
2013 - 06




Dell OpenManage Server Administrator (OMSA) provides a comprehensive, one-to-one systems management solution in two ways: from an integrated, web browser-based graphical user interface (GUI) and from a command line interface (CLI) through the operating system. Server Administrator enables system administrators to manage systems locally and remotely on a network. It enables system administrators to focus on managing their entire network by providing comprehensive one-to-one systems management. In the context of Server Administrator, a system refers to a stand- alone system, a system with attached network storage units in a separate chassis, or a modular system consisting of one or more server modules in a modular enclosure. Server Administrator provides information about:
Server Administrator provides easy-to-use management and administration of local and remote systems through a comprehensive set of integrated management services. Server Administrator is the sole installation on the system being managed and is accessible both locally and remotely from the Server Administrator home page. Remotely monitored systems may be accessed through dial-in, LAN, or wireless connections. Server Administrator ensures the security of its management connections through role-based access control (RBAC), authentication, and secure socket layer (SSL) encryption.
You can install Server Administrator using the Dell Systems Management Tools and Documentation DVD. The DVD provides a setup program to install, upgrade, and uninstall Server Administrator, managed system and management station software components. Additionally, you can install Server Administrator on multiple systems through an unattended installation across a network. The Dell OpenManage installer provides installation scripts and RPM packages to install and uninstall Dell OpenManage Server Administrator and other managed system software components on your managed system. For more information, see the Dell OpenManage Server Administrator Installation Guide and the Dell OpenManage Management Station Software Installation Guide at dell.com/support/manuals
To update individual system components, use component-specific Dell Update Packages. Use the Dell Server Update Utility DVD to view the complete version report and to update an entire system. The Server Update Utility (SUU) identifies and applies the required updates to your system. SUU can also be downloaded from support.dell.com.

The Storage Management Service provides storage management information in an integrated graphical view.
The Instrumentation Service provides rapid access to detailed fault and performance information gathered by industry- standard systems management agents and allows remote administration of monitored systems, including shutdown, startup, and security.
The Remote Access Controller provides a complete remote system management solution for systems equipped with the Dell Remote Access Controller (DRAC) or Baseboard Management Controller (BMC)/Integrated Dell Remote Access Controller (iDRAC) solution. The Remote Access Controller provides remote access to an inoperable system, allowing you to get the system up and running as quickly as possible. The Remote Access Controller also provides an alert notification when a system is down and allows you to remotely restart the system. Additionally, the Remote Access Controller logs the probable cause of system crashes and saves the most recent crash screen.
Server Administrator displays logs of commands issued to or by the system, monitored hardware events, and system alerts. You can view logs on the home page, print or save them as reports, and send them by e-mail to a designated service contact.
– Red Hat Enterprise Linux 5.9 (32–bit and 64–bit)
– Red Hat Enterprise Linux 6.4 (64–bit)
– Microsoft Windows Server 2012 Essentials
– VMware vSphere 5.1 U1
– VMware vSphere 5.0 U2
– Citrix XenServer 6.2
– Fixed CVE-2012-6272, CSRF, XSS, and generic path manipulation
– Upgraded to JRE version 1.7 Update 21
– Upgraded to Apache Tomcat version 7.0.39

– Broadcom 57840S Quad Port 10G SFP+ Rack NDC
– Broadcom 57840S-k Quad Port 10GbE Blade KR NDC
– PCIe SSD support for ESXi 5.1 U1.
– Remaining Rated Write Endurance status for SAS and SATA SSD attached to a PERC 8.
– Fluid Cache for direct attached storage (DAS) support on Red Hat Enterprise Linux 6.4 and Novell SUSE Linux Enterprise Server 11 SP2 for PERC H810, H710 Adapter, H710P, and H710 Mini on Dell PowerEdge R720, R820, R620, and T620.
– Red Hat Enterprise Linux 6.3
– Red Hat Enterprise Linux 5.8
Dell OpenManage Server Administrator supports the following systems management protocols:
If your system supports SNMP, you must install and enable the service on your operating system. If SNMP services are available on your operating system, the Server Administrator installation program installs the supporting agents for SNMP.
HTTPS is supported on all operating systems. Support for CIM and SNMP is operating system dependent and, in some cases, operating system-version dependent.
On supported Microsoft Windows operating systems, Server Administrator supports two systems management standards: CIM/Windows Management Instrumentation (WMI) and SNMP, while on supported Red Hat Enterprise Linux and SUSE Linux Enterprise Server operating systems, Server Administrator supports the SNMP systems management standard.

Server Administrator adds considerable security to these systems management standards. All attributes set operations (for example, changing the value of an asset tag) must be performed with Dell OpenManage IT Assistant while logged in with the required privileges.
The following table shows the systems management standards that are available for each supported operating system. Table 1. Systems Management Standards Availability
The Server Administrator home page provides easy-to-set up and easy-to-use Web browser-based system management tasks from the managed system or from a remote host through a LAN, dial-up service, or wireless network. When the Dell Systems Management Server Administrator Connection Service (DSM SA Connection Service) is installed and configured on the managed system, you can perform remote management functions from any system that has a supported Web browser and connection. Additionally, the Server Administrator home page provides an extensive, context-sensitive online help.
In addition to this guide, you can access the following guides available at dell.com/support/manuals

To access the documents from Dell Support site:

If at any time you do not understand a procedure described in this guide or if your product does not perform as expected, help tools are available to assist you. For more information about these help tools, see Getting Help in your system's Hardware Owner’s Manual.
Additionally, Dell Enterprise Training and Certification is available; see dell.com/training for more information. This service may not be offered in all locations.
To contact Dell for sales, technical support, or customer-service issues:
When you select a region, the countries for the selected regions are displayed.
The main support page for the selected business segment is displayed.

Dell OpenManage Server Administrator provides security through role- based access control (RBAC), authentication, and encryption for both the Web-based and command line interfaces.
RBAC manages security by determining the operations that can be executed by persons in particular roles. Each user is assigned one or more roles, and each role is assigned one or more privileges that are permitted to users in that role. With RBAC, security administration corresponds closely to an organization's structure.
Server Administrator grants different access rights based on the user's assigned group privileges. The four user privilege levels are: User, Power User, Administrator, and Elevated Administrator. Table 2. User Privileges
Privilege Levels to Access Server Administrator Services
The following table summarizes the users who have privileges to access and manage Server Administrator services.
Server Administrator grants read-only access to users logged in with User privileges, read and write access to users logged in with Power User privileges, and read, write, and administrator access to users logged in with Administrator and Elevated Administrator privileges. Table 3. Privileges Required To Manage Server Administrator Services
Service User Privilege Level Required
View Manage

Instrumentation User, Power User, Administrator, Elevated Administrator
Power User, Administrator, Elevated Administrator
Remote Access User, Power User, Administrator, Elevated Administrator
Storage Management User, Power User, Administrator, Elevated Administrator
The Server Administrator authentication scheme ensures that the correct access types are assigned to the correct user privileges. Additionally, when the command line interface (CLI) is invoked, the Server Administrator authentication scheme validates the context within which the current process is running. This authentication scheme ensures that all Server Administrator functions, whether accessed through the Server Administrator home page or CLI, are properly authenticated.
On supported Microsoft Windows operating systems, Server Administrator uses Integrated Windows Authentication (formerly called NTLM) to authenticate. This authentication system allows Server Administrator security to be incorporated in an overall security scheme for your network.
On supported Red Hat Enterprise Linux and SUSE Linux Enterprise Server operating systems, Server Administrator uses various authentication methods based on the Pluggable Authentication Modules (PAM) library. Users can log in to Server Administrator either locally or remotely using different account management protocols, such as LDAP, NIS, Kerberos, and Winbind.
VMware ESX Server uses the Pluggable Authentication Modules (PAM) structure for authentication when users access the ESX Server host. The PAM configuration for VMware services stores paths to the authentication modules and is located at /etc/pam.d/vmware-authd.
The default installation of ESX Server uses /etc/passwd authentication, similar to Linux, but you can configure ESX Server to use another distributed authentication mechanism.
ESXi Server authenticates users accessing ESXi hosts using the vSphere/VI Client or Software Development Kit (SDK). The default installation of ESXi uses a local password database for authentication. ESXi authentication transactions with Server Administrator are also direct interactions with the vmware-hostd process. To make sure that authentication works efficiently for your site, perform basic tasks such as setting up users, groups, permissions, and roles, configuring user attributes, adding your own certificates, and determining whether you want to use SSL.
Administrator, Elevated Administrator · Administrator, Elevated Administrator

Server Administrator is accessed over a secure HTTPS connection using secure socket layer (SSL) technology to ensure and protect the identity of the system being managed. Java Secure Socket Extension (JSSE) is used by supported Microsoft Windows, Red Hat Enterprise Linux, and SUSE Linux Enterprise Server operating systems to protect the user credentials and other sensitive data that is transmitted over the socket connection when a user accesses the Server Administrator home page.
To ensure critical system component security, assign user privileges to all Dell OpenManage software users before installing Dell OpenManage software. New users can log in to Dell OpenManage software using their operating system user privileges.
New users can log in to Dell OpenManage software with the user privileges for their assigned group and domain.
Creating Server Administrator Users For Supported Red Hat Enterprise Linux and SUSE Linux Enterprise Server Operating Systems
Administrator access privileges are assigned to the user logged in as root. To create users with User and Power User privileges, perform the following steps.

Creating Users With User Privileges
The new user can now log in to Server Administrator with User group privileges.
Creating Users With Power User Privileges
The new user can now log in to Server Administrator with Power User group privileges.
Editing Server Administrator User Privileges On Linux Operating Systems
The following table lists the legend for adding the role definition to the omarolemap file
Table 4. Legend for adding the role definition in OpenManage Server Administrator
User Name Host Name Administrator
(+) Group Name Domain User
Wildcard (*) Wildcard (*) User
[Tab] = \t (tab character)
The following table lists the examples for adding the role definition to the omarolemap file.
Creating Users ·

Table 5. Examples for adding the role definition in OpenManage Server Administrator
+ root Bhost Administrator
+ root Chost Administrator
Bob *.aus.amer.com Poweruser
Mike 192.168.2.3 Poweruser
Best Practices While Using The Omarolemap File
The following are the best practices to be considered while working with the omarolemap file :
– a user is degraded in the omarolemap file
– there are duplicate entries of user names or user groups along with same
Creating Server Administrator Users For VMware ESX 4.X, ESXi 4.X, And ESXi 5.X To add a user to the Users table:

A red circle with an X appears over the user name to indicate that the account is disabled.
Server Administrator supports the Simple Network Management Protocol (SNMP—a systems management standard— on all supported operating systems. The SNMP support may or may not be installed depending on your operating system and how the operating system was installed. In most cases, SNMP is installed as part of your operating system installation. An installed supported systems management protocol standard, such as SNMP, is required before installing Server Administrator.
You can configure the SNMP agent to change the community name, enable Set operations, and send traps to a management station. To configure your SNMP agent for proper interaction with management applications such as the Dell OpenManage IT Assistant, perform the procedures described in the following sections.
NOTE: For IT Assistant to retrieve management information from a system running Server Administrator, the community name used by IT Assistant must match a community name on the system running Server Administrator. For IT Assistant to modify information or perform actions on a system running Server Administrator, the community name used by IT Assistant must match a community name that allows Set operations on the system running Server Administrator. For IT Assistant to receive traps (asynchronous event notifications) from a system running Server Administrator, the system running Server Administrator must be configured to send traps to the system running IT Assistant.
The following procedures provide step-by-step instructions for configuring the SNMP agent for each supported operating system:
Configuring The SNMP Agent On Systems Running Supported Windows Operating Systems
Server Administrator uses the SNMP services provided by the Windows SNMP agent. You can configure the SNMP agent to change the community name, enable Set operations, and send traps to a management station. To configure

your SNMP agent for proper interaction with management applications such as IT Assistant, perform the procedures described in the following sections.
Enabling SNMP Access On Remote Hosts (Windows Server 2003 Only) Windows Server 2003, by default, does not accept SNMP packets from remote hosts. For systems running Windows Server 2003, you must configure the SNMP service to accept SNMP packets from remote hosts if you plan to manage the system by using SNMP management applications from remote hosts.
To enable a system running the Windows Server 2003 operating system to receive SNMP packets from a remote host:
The SNMP Service Properties window appears.
Changing The SNMP Community Name Configuring the SNMP community names determines which systems are able to manage your system through SNMP. The SNMP community name used by management applications must match an SNMP community name configured on the system running Server Administrator so that the management applications can retrieve management information from Server Administrator.
The SNMP Service Properties window appears.
To add a community name:
a. Click Add under the Accepted Community Names list.
The SNMP Service Configuration window appears. b. Type the community name of a system that is able to manage your system (the default is public) in the Community Name box and click Add.
The SNMP Service Properties window appears.
To edit a community name:
a. Select a community name in the Accepted Community Names list and click Edit.
The SNMP Service Configuration window appears. b. Edit the community name in the Community Name box, and then click OK .
The SNMP Service Properties window appears.

Enabling SNMP Set Operations SNMP Set operations must be enabled on the Server Administrator system to change Server Administrator attributes using IT Assistant.
The SNMP Service Properties window appears.
The SNMP Service Configuration window appears.
The SNMP Service Properties window appears.
Configuring Your System To Send SNMP Traps To A Management Station Server Administrator generates SNMP traps in response to changes in the status of sensors and other monitored parameters. You must configure one or more trap destinations on the system running Server Administrator for SNMP traps to be sent to a management station.
The SNMP Service Properties window appears.
a. To add a community for traps, type the community name in the Community Name box and click Add to list, which is located next to the Community Name box. b. To add a trap destination for a trap community, select the community name from the Community Name drop- down box and click Add under the Trap Destinations box.
The SNMP Service Configuration window appears. c. In the Host name, IP or IPX address box, type the trap destination, Add.
The SNMP Service Properties window appears.
Configuring The SNMP Agent On Systems Running Supported Red Hat Enterprise Linux
Server Administrator uses the SNMP services provided by the net-snmp SNMP agent. You can configure the SNMP agent to change the community name, enable Set operations, and send traps to a management station. To configure your SNMP agent for proper interaction with management applications such as IT Assistant, perform the procedures described in the following sections.
SNMP Agent Access Control Configuration
The management information base (MIB) branch implemented by Server Administrator is identified by the Object Identifier (OID) 1.3.6.1.4.1.674. Management applications must have access to this branch of the MIB tree to manage systems running Server Administrator.

For Red Hat Enterprise Linux and VMware ESXi 4.0 operating systems, the default SNMP agent configuration gives read- only access for the public community only to the MIB-II system branch (identified by the 1.3.6.1.2.1.1 OID) of the MIB tree. This configuration does not allow management applications to retrieve or change Server Administrator or other systems management information outside of the MIB-II system branch.
Server Administrator SNMP Agent Install Actions If Server Administrator detects the default SNMP configuration during installation, it attempts to modify the SNMP agent configuration to give read-only access to the entire MIB tree for the public community. Server Administrator modifies the SNMP agent configuration file /etc/snm, p/snmpd.conf by:
Server Administrator SNMP communicates with the SNMP agent using the SNMP Multiplexing (SMUX) protocol. When Server Administrator SNMP connects to the SNMP agent, it sends an object identifier to the SNMP agent to identify itself as a SMUX peer. Because that object identifier must be configured with the SNMP agent, Server Administrator adds the following line to the SNMP agent configuration file, /etc/snmp/snmpd.conf, during installation if it does not exist: smuxpeer .1.3.6.1.4.1.674.10892.1
Changing The SNMP Community Name Configuring the SNMP community name determines which systems are able to manage your system through SNMP. The SNMP community name used by management applications must match an SNMP community name configured on the system running Server Administrator, so that the management applications can retrieve management information from Server Administrator. To change the SNMP community name used for retrieving management information from a system running Server Administrator:
Enabling SNMP Set Operations SNMP Set operations must be enabled on the system running Server Administrator in order to change Server Administrator attributes using IT Assistant.

To enable SNMP Set operations on the system running Server Administrator, edit the SNMP agent configuration file, /etc/snmp/snmpd.conf, and perform the following steps:
Configuring Your System To Send Traps To A Management Station Server Administrator generates SNMP traps in response to changes in the status of sensors and other monitored parameters. One or more trap destinations must be configured on the system running Server Administrator for SNMP traps to be sent to a management station.
To configure your system running Server Administrator to send traps to a management station, edit the SNMP agent configuration file, /etc/snmp/snmpd.conf, and perform the following steps:
Configuring The SNMP Agent On Systems Running Supported SUSE Linux Enterprise Server
Server Administrator uses the SNMP services provided by the net-snmp agent. You can configure the SNMP agent to enable SNMP access from remote hosts, change the community name, enable Set operations, and send traps to a management station. To configure your SNMP agent for proper interaction with management applications such as IT Assistant, perform the procedures described in the following sections.
Sever Administrator SNMP Install Actions
Server Administrator SNMP communicates with the SNMP agent using the SMUX protocol. When Server Administrator SNMP connects to the SNMP agent, it sends an object identifier to the SNMP agent to identify itself as a SMUX peer. This object identifier must be configured with the SNMP agent, therefore, Server Administrator adds the following line to the SNMP agent configuration file, /etc/snmp/snmpd.conf, during installation if it does not exist: smuxpeer .1.3.6.1.4.1.674.10892.1
Enabling SNMP Access From Remote Hosts The default SNMP agent configuration on SUSE Linux Enterprise Server operating systems gives read-only access to the entire MIB tree for the public community from the local host only. This configuration does not allow SNMP management applications such as IT Assistant running on other hosts to discover and manage Server Administrator systems properly. If Server Administrator detects this configuration during installation, it logs a message to the operating system log file, /var/log/messages, to indicate that SNMP access is restricted to the local host. You must configure the SNMP agent to enable SNMP access from remote hosts if you plan to manage the system by using SNMP management applications from remote hosts.
To enable SNMP access from a specific remote host to a system running Server Administrator, edit the SNMP agent configuration file, /etc/snmp/snmpd.conf, and perform the following steps:

To enable SNMP access from all remote hosts to a system running Server Administrator, edit the SNMP agent configuration file, /etc/snmp/snmpd.conf, and perform the following steps:
Changing The SNMP Community Name Configuring the SNMP community name determines which management stations are able to manage your system through SNMP. The SNMP community name used by management applications must match the SNMP community name configured on the system running Server Administrator,, so the management applications can retrieve the management information from Server Administrator.
To change the default SNMP community name used for retrieving management information from a system running Server Administrator:
Enabling SNMP Set Operations SNMP Set operations must be enabled on the system running Server Administrator in order to change Server Administrator attributes using IT Assistant. To enable remote shutdown of a system from IT Assistant, SNMP Set operations must be enabled.
To enable SNMP Set operations on a system running Server Administrator:
Configuring The SNMP Agent On Systems Running Supported VMware ESX 4.X Operating Systems To Proxy VMware MIBs The ESX 4.X server can be managed through a single default port 162 using the SNMP protocol. To do this, snmpd is configured to use the default port 162 and vmwarehostd is configured to use a different (unused) port, for example, 167. Any SNMP request on the VMware MIB branch is rerouted to the vmware-hostd using the proxy feature of the snmpd daemon.
The VMWware SNMP configuration file can be modified manually on the ESX server or by running the VMware Remote Command-Line Interface (RCLI) command, vicfg-snmp, from a remote system (Windows or Linux). The RCLI tools can be downloaded from the VMware website at vmware.com/download/vi/drivers_tools.html
To configure the SNMP agent:

a. vicfg-snmp.pl --server --username root --password -c -p X –t @162/
Where represents an unused port. To find an unused port, check the /etc/services file for the port assignment for defined system services. Also, to make sure that the port selected is not currently being used by any application or service, run the following command on the ESX server: netstat –a command
To enable VMWare SNMP service, run the following command: b. vicfg-snmp.pl --server --username root --password - E
To view the configuration settings, run the following command: c. vicfg-snmp.pl --server --username root --password -s
The following is an example of the configuration file, after modification: true public 143.166.152.248@162/public 167
Where X represents the unused port specified above, while configuring SNMP.
The trapsink specification is required to send traps defined in the proprietary MIBs.
Configuring The SNMP Agent On Systems Running Supported VMware ESXi 4.X And ESXi 5.X Operating Systems
Server Administrator supports SNMP traps on VMware ESXi 4.X and ESXi 5.X. If a stand-alone license is only present, SNMP configuration fails on VMware ESXi operating systems. Server Administrator does not support SNMP Get and Set operations on VMWare ESXi 4.X and ESXi 5.X as the required SNMP support is unavailable. The VMware vSphere Command- Line Interface (CLI) is used to configure systems running VMware ESXi 4.X and ESXi 5.X to send SNMP traps to a management station.

Configuring Your System To Send Traps To A Management Station Server Administrator generates SNMP traps in response to changes in the status of sensors and other monitored parameters. One or more trap destinations must be configured on the system running Server Administrator for SNMP traps to be sent to a management station.
To configure your ESXi system running Server Administrator to send traps to a management station:
where is the hostname or IP address of the ESXi system, is a user on the ESXi system, is the SNMP community name and is the hostname or IP address of the management station.
The SNMP trap configuration takes effect immediately without restarting any services.
Firewall Configuration On Systems Running Supported Red Hat Enterprise Linux Operating Systems And SUSE Linux Enterprise Server
If you enable firewall security while installing Red Hat Enterprise Linux/SUSE Linux, the SNMP port on all external network interfaces is closed by default. To enable SNMP management applications such as IT Assistant to discover and retrieve information from Server Administrator, the SNMP port on at least one external network interface must be open. If Server Administrator detects that the SNMP port is not open in the firewall for any external network interface, Server Administrator displays a warning message and logs a message to the system log.
You can open the SNMP port by disabling the firewall, opening an entire external network interface in the firewall, or opening the SNMP port for at least one external network interface in the firewall. You can perform this action before or after Server Administrator is started.
To open the SNMP port on Red Hat Enterprise Linux using one of the previously described methods:
The Choose a Tool menu appears.
The Firewall Configuration screen appears.
a. To disable the firewall, select No firewall or Disabled and go to Step7.

b. To open an entire network interface or the SNMP port, select High, Medium, or Enabled and proceed to step 4.
The Firewall Configuration-Customize screen appears.
a. To open an entire network interface, press to go to one of the Trusted Devices and press the spacebar. An asterisk in the box to the left of the device name indicates that the entire interface is opened. b. To open the SNMP port on all network interfaces, press to go to Other ports and type snmp:udp.
The Firewall Configuration screen appears.
The Choose a Tool menu appears.
Firewall Configuration To open the SNMP port on SUSE Linux Enterprise Server:

To start a Server Administrator session, double-click the Dell OpenManage Server Administrator icon on your desktop.
The Server Administrator Log in screen is displayed. The default port for Dell OpenManage Server Administrator is 1311. You can change the port, if required. For instructions on setting up your system preferences, see Dell Systems Management Server Administration.
OpenManage Server Administrator provides the following types of logins:
This login is available only if the Server Instrumentation and Server Administrator Web Server components are installed on the local system.
This option is unavailable for servers running on XenServer 6.0.
To log in to Server Administrator on a local system:
If you are accessing Server Administrator from a defined domain, you must also specify the correct Domain name.
To end your Server Administrator session, click Log Out located in the upper-right corner of each Server Administrator home page.

This login is available only if the Server Administrator Web Server component is installed on the system. To log in to Server Administrator to manage a remote system:
NOTE: If you have entered the system name or FQDN, Dell OpenManage Server Administrator Web Server host converts the system name or FQDN to the IP address of the managed system. You can also enter the port number of the managed system. For example, Hostname:Port number, or IP address:Port number. If you are connecting to a Citrix XenServer 6.0 managed node, use port 5986 in the format Hostname:Port number, or IP address:Port number.
This login is available only if the Server Administrator Web Server component is installed on the system. Use this login to manage the OpenManage Server Administrator Central Web Server:
To end your Server Administrator session, click Log Out on the Global Navigation Bar.

NOTE: When you launch Server Administrator using either Mozilla Firefox version 3.0 and 3.5 or Microsoft Internet Explorer version 7.0 or 8.0, an intermediate warning page may appear displaying a problem with security certificate. To ensure system security, it is recommended that you generate a new X.509 certificate, reuse an existing X.509 certificate, or import a root certificate or certificate chain from a Certification Authority (CA). To avoid encountering such warning messages about the certificate, the certificate used must be from a trusted CA. For more information about X.509 Certificate Management, see X.509 Certificate Management.
NOTE: If the certificate authority on the managed system is valid and if the Server Administrator web server still reports an untrusted certificate error, you can still make the managed system’s CA as trusted by using the certutil.exe file. For information about accessing this .exe file, see your operating system documentation. On supported Windows operating systems, you can also use the certificates snap in option to import certificates.
You should select Active Directory Login to log in using the Dell Extended Schema Solution in Active Directory.
This solution enables you to provide access to Server Administrator; allowing you to add/control Server Administrator users and privileges to existing users in your Active Directory software. For more information, seev“Using Microsoft Active Directory” in the Dell OpenManage Installation and Security User's Guide at dell.com/support/manuals
The Single Sign-On option in Windows operating systems enables all logged in users to bypass the login page and access the Server Administrator Web application by clicking the Dell OpenManage Server Administrator icon on your desktop.
For local machine access, you must have an account on the machine with the appropriate privileges (User, Power User, or Administrator). Other users are authenticated against the Microsoft Active Directory. To launch Server Administrator using Single Sign-On authentication against Microsoft Active Directory, the following parameters must also be passed: authType=ntlm&application=[plugin name]
where plugin name = omsa, ita, and so on. For example, https://localhost:1311/?authType=ntlm&application=omsa
To launch Server Administrator using Single Sign-On authentication against the local machine user accounts, the following parameters must also be passed: authType=ntlm&application=[plugin name]&locallogin=true
Where plugin name = omsa, ita, and so on. For example, https://localhost:1311/?authType=ntlm&application=omsa&locallogin=true
Server Administrator has also been extended to allow other products (such as Dell OpenManage IT Assistant) to directly access Server Administrator Web pages without going through the login page (if you are currently logged in and have the appropriate privileges).

You must configure the security settings for your browser to log in to Server Administrator from a remote management system that is running a supported Microsoft Windows operating system.
The security settings for your browser may prevent the execution of client-side scripts that are used by Server Administrator. To enable the use of client-side scripting, perform the following steps on the remote management system.
Enabling The Use Of Client-Side Scripts On Internet Explorer
The Internet Options window is displayed.
For Windows Server 2003:
a. Under Miscellaneous, select Allow Meta Refresh. b. Under Active Scripting, select Enable. c. Under Active Scripting, select Allow scripting of Internet Explorer web browser controls.
Enabling Single Sign-On For Server Administrator On Internet Explorer To allow Single Sign-On for Server Administrator without prompts for user credentials:
Enabling The Use Of Client-Side Scripts On Mozilla Firefox

With only a few exceptions, the Server Administrator home page has three main areas:
– The action tabs display the primary actions or categories of actions that are available for the selected object based on the user's access privileges.
– The action tabs are divided into subcategories of all available secondary options for the action tabs based on the user's access privileges.
– The data area displays information for the selected system tree object, action tab, and subcategory based on the user's access privileges.
Additionally, when logged in to the Server Administrator home page, the system model, the assigned name of the system, and the current user's user name and user privileges are displayed in the top-right corner of the window.
The following table lists the GUI field names and the applicable system, when Server Administrator is installed on the system. Table 6. GUI Field Names And The Applicable Systems
GUI Field Name Applicable System
Modular Enclosure Modular system
Server Module Modular system
Main System Modular system
Main System Chassis Non-modular system
The following figure shows a sample Server Administrator home page layout for a user logged in with administrator privileges on a non-modular system.
System Non-modular system


Figure 1. Sample Server Administrator Home Page — Non-Modular System
The following figure shows a sample Server Administrator home page layout for a user logged in with administrator privileges on a modular system.

Figure 2. Sample Server Administrator Home Page — Modular System
Clicking an object in the system tree opens a corresponding action window for that object. You can navigate in the action window by clicking the action tabs to select major categories and clicking the action tab subcategories to access more detailed information or more focused actions. The information displayed in the data area of the action window can range from system logs to status indicators to system probe gauges. Underlined items in the data area of the action window indicate a further level of functionality. Clicking an underlined item creates a new data area in the action window that contains a greater level of detail. For example, clicking Main System Chassis/Main System under the Health subcategory of the Properties action tab lists the health status of all the components contained in the Main System Chassis/Main System object that are monitored for health status.

The following table lists the availability of Server Administrator features across modular and non-modular systems. Table 7. Server Administrator User Interface Differences Across Modular and Non- Modular Systems
Features Modular System Non-Modular System
Modular Enclosure (Chassis Information and CMC Information)

The global navigation bar and its links are available to all user levels in the program.
The system tree appears on the left side of the Server Administrator home page and lists the components of your system that are viewable. The system components are categorized by component type. When you expand the main object known as Modular Enclosure → System/Server Module, the major categories of system/server module components that may appear are Main System Chassis/Main System, Software, and Storage.
To expand a branch of the tree, click the plus sign (
) to the left of an object, or double-click the object. A minus sign
) indicates an expanded entry that cannot be expanded further.
When you click an item on the system tree, details about the component or object appear in the data area of the action window. Clicking an action tab displays all available user options as a list of subcategories.
Clicking an object on the system/server module tree opens that component's action window, displaying the available action tabs. The data area defaults to a preselected subcategory of the first action tab for the selected object.
The preselected subcategory is usually the first option. For example, clicking the Main System Chassis/Main System object opens an action window in which the Properties action tab and Health subcategory are displayed in the window's data area.
The data area is located below the action tabs on the right side of the home page. The data area is where you perform tasks or view details about system components. The content of the window depends on the system tree object and action tab that is currently selected. For example, when you select BIOS from the system tree, the Properties tab is selected by default and the version information for the system BIOS appears in the data area. The data area of the action window contains many common features, including status indicators, task buttons, underlined items, and gauge indicators.
The Server Administrator user interface displays the date in the format.
System/Server Module Component Status Indicators
The icons that appear next to component names show the status of that component (as of the latest page refresh). Table 8. System/Server Module Component Status Indicators
The component is healthy (normal).
The component has a warning (non-critical) condition. A warning condition occurs when a probe or other monitoring tool detects a reading for a component that falls within certain minimum and maximum values. A warning condition requires prompt attention.
( · Description Icon

The component has a failed or critical condition. A critical condition occurs when a probe or other monitoring tool detects a reading for a component that falls within certain minimum and maximum values. A critical condition requires immediate attention.
The component's health status is unknown.
Most windows opened from the Server Administrator home page contain at least five task buttons: Print, Export, Email, Help and Refresh. Other task buttons are included on specific Server Administrator windows. The Log window, for example, also contain Save As and Clear Log task buttons.
) prints a copy of the open window to your default printer.
) generates a text file that lists the values for each data field on the open window. The export file is saved to a location you specify. For information about customizing the delimiter separating the data field values see, "Setting User"and "System Preferences."
) creates an e-mail message addressed to your designated e-mail recipient. For instructions on setting up your e-mail server and default e-mail recipient, see "Setting User"and "System Preferences."
) reloads the system component status information in the action window data area.
) provides detailed information about the specific window or task button you are viewing.
Clicking an underlined item in the action window data area displays additional details about that item.
Temperature probes, fan probes, and voltage probes are each represented by a gauge indicator. For example, the following figure shows readings from a system's CPU fan probe.


Figure 3. Gauge Indicator
Context-sensitive online help is available for every window of the Server Administrator home page. Clicking Help opens an independent help window that contains detailed information about the specific window you are viewing. The online help is designed to guide you through the specific actions required to perform all aspects of the Server Administrator services. Online help is available for all windows you can view, based on the software and hardware groups that Server Administrator discovers on your system and your user privilege level.
The left-hand pane of the Preferences home page (where the system tree is displayed on the Server Administrator home page) displays all available configuration options in the system tree window.
The available Preferences home page configuration options are:
You can view the Preferences tab after you log in to manage a remote system. This tab is also available when you log in to manage the Server Administrator Web server or manage the local system.
Like the Server Administrator home page, the Preferences home page has three main areas:
– Click Home to return to the Server Administrator home page.
The following figure shows a sample Preferences home page layout.


Figure 4. Sample Preferences Home Page - Managed System
When you log in to a remote system, the Preferences home page defaults to the Node Configuration window under the Preferences tab.
Click the Server Administrator object to enable or disable access to users with User or Power User privileges. Depending on the user’s group privileges, the Server Administrator object action window may have the Preferences tab.
Under the Preferences tab, you can:
When you log in to manage the Server Administrator Web server, the Preferences home page defaults to the User Preferences window under the Preferences tab.
Due to the separation of the Server Administrator Web server from the managed system, the following options are displayed when you log in to the Server Administrator Web server, using the Manage Web Server link:
For more information about accessing these features, see Server Administrator Services Overview.
Setting User And System Preferences You can set user and secure port system preferences from the Preferences home page.

Set up your user preferences:
The Preferences home page appears.
) in any window to send an e-mail message with an attached HTML file of the window to the designated e-mail address.
Secure Port System Perform the following steps to set up your secure port system preferences:
The Preferences home page appears.

– Auto Negotiate — Allows connection from browser with any encryption strength. The browser auto negotiates with the Server Administrator Web Server and uses the highest available encryption level for the session. Legacy browsers with weaker encryption can also connect to the Server Administrator.
– 128-bit or Higher — Allows connections from browsers with 128-bit or higher encryption strength. One of the following cipher suites is applicable based on the browser for any established sessions:
Web certificates are necessary to ensure the identity of a remote system and ensure that information exchanged with the remote system are not viewed or changed by others. To ensure system security, it is recommended that:
To manage X.509 certificates through the Preferences home page, click General Settings, click the Web Server tab, and click X.509 Certificate.
The following are the available options:

The following are the action tabs that are displayed when you log in to manage the Server Administrator web server:
The Server Administrator command line interface (CLI) allows users to perform essential systems management tasks from the operating system command prompt of a monitored system.
The CLI allows a user with a very well-defined task in mind to rapidly retrieve information about the system. Using CLI commands, for example, administrators can write batch programs or scripts to execute at specific times. When these programs execute, they can capture reports on components of interest, such as fan RPMs. With additional scripting, the CLI can be used to capture data during periods of high system usage to compare with the same measurements at times of low system usage. Command results can be routed to a file for later analysis. The reports can help administrators to gain information that can be used to adjust usage patterns, to justify purchasing new system resources, or to focus on the health of a problem component.
For complete instructions on the functionality and use of the CLI, see the Dell OpenManage Server Administrator Command Line Interface Guide at dell.com/support/manuals

The Dell OpenManage Server Administrator Instrumentation Service monitors the health of a system and provides rapid access to detailed fault and performance information gathered by industry-standard systems management agents. The reporting and viewing features allow retrieval of the overall health status for each chassis that comprises your system. At the subsystem level, you can view information about the voltages, temperatures, fan rpm, and memory function at key points in the system. A detailed account of every relevant cost of ownership (COO) detail about your system can be seen in the summary view. Version information for BIOS, firmware, operating system, and all installed systems management software can also be retrieved.
Additionally, system administrators can use the Instrumentation Service to perform the following essential tasks:
The Server Administrator home page defaults to the System object of the system tree view. By default, for the System object opens the Health components under the Properties tab.
By default, the Preferences home page, opens the Node Configuration.
From the Preferences home page, you can restrict access to users with User and Power User privileges, set the SNMP password, and configure user settings and SM SA Connection Service settings.
) to open an independent help window that contains detailed information about the specific window you are viewing. The online help is designed to guide you through the specific actions required to perform all aspects of the Server Administrator services. Online help is available for all windows you can view, based on the software and hardware groups that Server Administrator discovers on your system and your user privilege level.
Help (

The Server Administrator system/server module tree displays all visible system objects based on the software and hardware groups that Server Administrator discovers on the managed system and on the user's access privileges. The system components are categorized by component type. When you expand the main object — Modular Enclosure — System/Server Module — the major categories of system components that may appear are, Main System Chassis/Main System, Software, and Storage.
If Storage Management Service is installed, depending on the controller and storage attached to the system, the Storage tree object expands to display various objects.
For detailed information on the Storage Management Service component, see the Dell OpenManage Server Administrator Storage Management User's Guide at dell.com/support/manuals
This section provides information about the objects in the System tree on the Server Administrator's home page. Due to the limitations of the VMware ESX and ESXi version 4.X and 5.X operating systems, some features available in earlier versions of OpenManage Server Administrator are not available in this release. These include:
NOTE: For the purposes of Server Administrator, modular enclosure refers to a system that may contain one or more modular systems that appear as a separate Server Module in the system tree. Like a stand-alone Server Module, a modular enclosure contains all of the essential components of a system. The only difference is that there are slots for at least two Server Modules within a larger container, and each of them is as complete a system as a Server Module.

To view the modular system’s chassis information and Chassis Management Controller (CMC) information, click the Modular Enclosure object.
Under the Properties tab, you can:
To launch the Chassis Management Controller Log in window from the Server Administrator home page:
You can monitor and manage your modular enclosure after connecting to the CMC.
The System/Server Module object contains three main system component groups: Main System Chassis/Main System , Software , and Storage . The Server Administrator home page defaults to the System object of the system tree view. Most administrative functions can be managed from the System/Server Module object action window. The System/ Server Module object action window has the following tabs, depending on the user's group privileges: Licensing, Properties, Shutdown, Logs, Alert Management, and Session Management
Under the Licensing sub tab, you can:
Under the Properties tab, you can:
Licensing · Properties

NOTE: Automatic System Recovery actions may not execute exactly per the time-out period (n seconds) when the watchdog identifies a system that has stopped responding. The action execution time ranges from n-h+1 to n+1 seconds, where n is the time-out period and h is the heart beat interval. The value of the heart beat interval is 7 seconds when n 30.
NOTE: The functionality of the watchdog timer feature cannot be guaranteed when an uncorrectable memory event occurs in the system DRAM Bank_1. If an uncorrectable memory event occurs in this location, the BIOS code resident in this space may become corrupted. Because the watchdog feature uses a call to BIOS to effect the shutdown or reboot behavior, the feature may not work properly. If this occurs, you must manually reboot the system. The watchdog timer can be set to a maximum of 720 seconds.
Under the Shutdown tab, you can:
Under the Logs tab, you can:
) to noncritical status (
) when the log file reaches 80 percent capacity. On Dell PowerEdge 9G and 11G
systems, the status indicator icon next to the log name changes to critical status (
) when the log file reaches 100 percent capacity.
Under the Alert Management tab, you can:

Under the Session Management tab, you can:
Click the Main System Chassis/Main System object to manage your system's essential hardware and software components.
The available components are:
Session Management

NOTE: Hardware performance is supported only on Dell PowerEdge 10G and later systems. The Power Supplies option is not available on Dell PowerEdge 1900. Power management is supported on limited Dell PowerEdge 10G and later systems. Power Supply Monitoring and Power Monitoring features are available only for systems that have two or more redundant, hot-swappable power supplies installed. These features are unavailable for permanently installed, non-redundant power supplies that lack power management circuitry.
Main System Chassis/Main System Properties
The system/server module may contain one main system chassis or several chassis. The main system chassis/main system contains the essential components of a system. The Main System Chassis/Main System object action window includes the following:
Under the Properties tab, you can:
Module Component Status Indicators icon next to its name.
indicates that a component is healthy (normal).
indicates that a component has a warning (noncritical) condition and requires prompt attention.
component has a failure (critical) condition and requires immediate attention.
indicates that a component's health status is unknown. The available monitored components include:
NOTE: Batteries are supported only on Dell PowerEdge 9G and Dell PowerEdge 10G systems. The Power supplies is not available on Dell PowerEdge 1900. Power management is supported on limited Dell PowerEdge 10G systems. Power Supply Monitoring and Power Monitoring features are available only for systems that have two or more redundant, hot-swappable power supplies installed. These features are unavailable for permanently installed, non-redundant power supplies that lack power management circuitry.
Properties · indicates that a

system’s LCD information can be selected from the drop-down menu. You can also enable Indication of Remote KVM session from the Front Panel sub tab.
Click the Batteries object to view information about your system’s installed batteries. Batteries maintain the time and date when your system is turned off. The battery saves the system’s BIOS setup configuration, which allows the system to reboot efficiently. The Batteries object action window can have the following tabs, depending on the user’s group privileges: Properties and Alert Management.
Under the Properties tab, you can view the current readings and status of your system’s batteries.
Under the Alert Management tab, you can configure the alerts that you want to take effect in case of a battery warning or critical/failure event. BIOS
Click the BIOS object to manage key features of your system's BIOS. Your system’s BIOS contains programs stored on a flash memory chipset that control communications between the microprocessor and peripheral devices, such as the keyboard and the video adapter, and other miscellaneous functions, such as system messages. The BIOS object action window can have the following tabs, depending on the user's group privileges:
Under the Properties tab, you can view BIOS information.
Under the Setup tab, you can set the state for each BIOS setup object.
You can modify the state of many BIOS setup features including but not limited to the Serial Port, Hard Disk Drive Sequence, User Accessible USB Ports, CPU Virtualization Technology, CPU HyperThreading, AC Power Recovery Mode, Embedded SATA Controller, System Profile, Console Redirection, and Console Redirection Failsafe Baud Rate. You can also configure internal USB device, optical drive controller settings, automatic system recovery (ASR) Watchdog Timer, embedded hypervisor, and additional LAN network ports on motherboard information. You can also view the Trusted Platform Module (TPM) and Trusted Cryptographic Module (TCM) settings.
Depending on your specific system configuration, additional setup items may be displayed. However, some BIOS setup options may be shown on the BIOS Setup screen that are not accessible in Server Administrator.
For 12G systems, the configurable BIOS features are grouped as specific categories. The categories include System Information, Memory Settings, System Profile Settings, Unified Extensible Firmware Interface (UEFI) Boot Settings, Network Interface Controller cards, One-Time Boot, and Slot Disablement. For example, on the System BIOS Settings page, when you click the Memory Settings link , the features pertaining to the system memory appear. You can view or modify the settings by navigating to the respective categories.
You can set a BIOS Setup password, on theBIOS Setup - System Security page. You must enter the password to enable and modify the BIOS settings. Else, the BIOS settings appear in a read-only mode. You must restart the system after setting the password.
When pending values from the previous session exist or the inband configuration is disabled from an out-of-band interface, Server Administrator does not allow BIOS Setup configuration.

Click the Fans object to manage your system fans. Server Administrator monitors the status of each system fan by measuring fan RPMs. Fan probes report RPMs to the Server Administrator Instrumentation Service. When you select Fans from the device tree, details appear in the data area in the right-side pane of the Server Administrator home page. The Fans object action window can have the following tabs, depending on the user's group privileges: Properties and Alert Management.
Under the Properties tab, you can:
Under the Alert Management tab, you can:
Click the Firmware object to manage your system firmware. Firmware consists of programs or data that have been written to ROM. Firmware can boot and operate a device. Each controller contains firmware that helps provide the controller's functionality. The Firmware object action window can have the following tab, depending on the user's group privileges: Properties.
Under the Properties tab, you can view your system's firmware information. Hardware Performance
Click the Hardware Performance object to view the status and cause for the system’s performance degradation. The Hardware Performance object action window can have the following tab, depending on the user's group privileges: Properties.
The following table lists the possible values for status and cause of a probe: Table 9. Possible Values For Status And Cause Of A Probe
Status Values Cause Values
Degraded User Configuration Insufficient Power Capacity

Under the Properties tab, you can view the details of system’s performance degradation. Intrusion
Click the Intrusion object to manage your system's chassis intrusion status. Server Administrator monitors chassis intrusion status as a security measure to prevent unauthorized access to your system's critical components. Chassis intrusion indicates that someone is opening or has opened the cover of the system's chassis. The Intrusion object action window can have the following tabs, depending on the user's group privileges: Properties and Alert Management
Under the Properties tab, you can view the chassis intrusion status.
Under the Alert Management tab, you can:
Click the Memory object to manage your system's memory devices. Server Administrator monitors the memory device status for each memory module present in the monitored system. Memory device prefailure sensors monitor memory modules by counting the number of ECC memory corrections. Server Administrator also monitors memory redundancy information if your system supports this feature. The Memory object action window can have the following tabs, depending on the user's group privileges: Properties and Alert Management.
Under the Properties tab, you can view the memory redundancy status, memory array attributes, total capacity of the memory arrays, details of memory arrays, memory device details, and memory device status. The memory device details provides the details of a memory device on a connector such as the status, device name, size, type, speed, rank, and failures. A rank is a row of dynamic random access memory (DRAM) devices comprising 64 bits of data per Dual Inline Memory Module (DIMM). The possible values of rank are single, dual, quad, octal, and hexa. The rank displays the rank of the DIMM and helps in the easy service of DIMMs on the server.
Under the Alert Management tab, you can:

Click the Network object to manage your system's NICs. Server Administrator monitors the status of each NIC present in your system to ensure continuous remote connection. Dell OpenManage Server Administrator reports FCoE and iSoE capabilities of the NICs. Also, NIC teaming details are reported if they are already configured on the system. Two or more physical NICs can be teamed into a single logical NIC, to which an administrator can assign an IP address. Teaming can be configured using NIC vendor tools. For example, Broadcom - BACS. If one of the physical NICs fails, the IP address remains accessible because it is bound to the logical NIC rather than to a single physical NIC. If Team Interface is configured, the detailed team properties are displayed. The relation between physical NICs and Team Interface and vice-versa is also reported, if these physical NICs are members of the Team Interface.
On Windows 2008 Hypervisor operating system, Server Administrator does not report the IP addresses of the physical NIC ports that are used to assign an IP to a virtual machine.
In case of ESX and ESXi operating systems, the network device is considered a group. For example, the virtual ethernet interface that is used by the Service Console (vswif) and virtual network interface that is used by VMKernel (vmknic) devices on ESX and vmknic device on ESXi.
The Network object action window can have the following tab, depending on the user's group privileges: Properties.
Under the Properties tab, you can view information about the physical NIC interfaces and also the team interfaces installed on your system.
Click the Ports object to manage your system's external ports. Server Administrator monitors the status of each external port present in your system.
The Ports object action window can have the following tab, depending on the user's group privileges: Properties.
Under the Properties tab, you can view information about your system's internal and external ports. Power Management
Under the Consumption tab you can view and manage your system’s Power Consumption information in Watts and BTU/hr.
BTU/hr = Watt X 3.413 (value rounded off to the nearest whole number)
Server Administrator monitors power consumption status, amperage, and tracks power statistic details.

You can also view the System Instantaneous Headroom and System Peak Headroom. The values are displayed in both Watts and BTU/hr (British Thermal Unit). Power thresholds can be set in Watts and BTU/hr.
The Statistics tab allows you to view and reset your system’s Power tracking statistics like energy consumption, system peak power, and system peak amperage.
The Budget tab allows you to view the Power Inventory attributes like System Idle Power and System Maximum Potential Power in Watts and BTU/hr. You can also use the Power Budget option to Enable Power Cap and set the Power Cap for your system.
The Profiles tab allows you to choose a power profile to maximize your system’s performance and conserve energy.
Use the Alert Actions tab to set system alert actions for various system events like System Power Probe Warning and System Peak Power.
Use the SNMP Traps tab to configure SNMP traps for your system.
Certain Power Management features may be available only on systems enabled with the Power Management Bus (PMBus). Power Supplies
Click the Power Supplies object to manage your system’s power supplies. Server Administrator monitors power supply status, including redundancy, to ensure that each power supply present in your system is functioning properly. The Power Supplies object action window can have the following tabs, depending on the user's group privileges: Properties and Alert Management.
Under the Properties tab, you can:
Under the Alert Management tab, you can:

Click the Processors object to manage your system's microprocessor(s). A processor is the primary computational chip inside a system that controls the interpretation and execution of arithmetic and logic functions. The Processors object action window can have the following tabs, depending on the user's group privileges: Properties and Alert Management.
Under the Properties tab, you can view information about your system's microprocessor(s) and access detailed capabilities and cache information.
Under the Alert Management tab, you can view current alert actions settings and set the alert actions that you want to be performed in the event that a processor returns a warning or failure value. Remote Access
Click the Remote Access object to manage the Baseboard Management Controller (BMC) or Integrated Dell Remote Access Controller (iDRAC) features and Remote Access Controller features.
Selecting Remote Access tab allows you to manage the BMC/iDRAC features such as, general information on the BMC/ iDRAC. You can also manage the configuration of the BMC/iDRAC on a local area network (LAN), serial port for the BMC/iDRAC, terminal mode settings for the serial port, BMC/iDRAC on a serial over LAN connection, and BMC/iDRAC users.
DRAC allows you to access your system's remote system management capabilities. The Server Administrator DRAC provides remote access to inoperable systems, alert notification when a system is down, and the ability to restart a system.
The Remote Access object action window can have the following tabs, depending on the user's group privileges:Properties, Configuration, and Users.
Under the Properties tab, you can view general information on the remote access device. You can also view the attributes of the IPv4 and IPv6 addresses.
Click Reset to Defaults to reset all the attributes to their system default values.
Under the Configuration tab when BMC/iDRAC is configured, you can configure the BMC/iDRAC on a LAN, serial port for BMC/iDRAC, and BMC/iDRAC on a serial over LAN connection.
Under the Configuration tab, when DRAC is configured, you can configure network properties.
Under the Additional Configuration tab you can either enable or disable IPv4/IPv6 properties.

Under the Users tab, you can modify the remote access user configuration. You can add, configure, and view information about Remote Access Controller users.
- Ten user IDs are displayed. If a DRAC card is installed, sixteen user IDs are displayed.
- Serial Over LAN Payload column is displayed.
Click the Removable Flash Media object to view the health and redundancy status of the Internal SD Modules and vFlash media. The Removable Flash Media action window has the Properties tab.
Under the Properties tab, you can view information about the Removable Flash Media and Internal SD Modules. This includes details about the Connector Name, its state, and storage size.
Under the Alert Management tab, you can:
Alert management is common for Internal SD modules and vFlash. Configuring alert actions/SNMP/PEF for either the SD modules or vFlash automatically configures it for the other. Slots
Click the Slots object to manage the connectors or sockets on your system board that accept printed circuit boards, such as expansion cards. The Slots object action window has a Properties tab.
Under the Properties tab, you can view information about each slot and installed adapter. Temperatures
Click the Temperatures object to manage your system temperature in order to prevent thermal damage to your system’s internal components. Server Administrator monitors the temperature in a variety of locations in your system's chassis to ensure that temperatures inside the chassis do not become too high. The Temperatures object action window displays the following tabs, depending on the user's group privileges: Properties and Alert Management.
Under the Properties tab, you can view the current readings and status of your system's temperature probes and configure minimum and maximum values for temperature probe warning threshold.

Under the Alert Management tab, you can:
Click the Voltages object to manage voltage levels in your system. Server Administrator monitors voltages across critical components in various chassis locations in the monitored system. The Voltages object action window can have the following tabs, depending on the user's group privileges: Properties and Alert Management.
Under the Properties tab, you can view the current readings and status of your system's voltage probes and configure minimum and maximum values for voltage probe warning threshold.
Under the Alert Management tab, you can:
Click the Software object to view detailed version information about the managed system's essential software components, such as the operating system and the systems management software. The Software object action window has the following tab, depending on the user's group privileges: Properties.
Under the Properties tab, you can view a summary of the monitored system's operating system and system management software.
Click the Operating System object to view basic information about your operating system. The Operating System object action window has the following tab, depending on the user's group privileges: Properties.

Under the Properties tab, you can view basic information about your operating system.
Server Administrator provides the Storage Management Service:
The Storage Management Service provides features for configuring storage devices. In most cases, the Storage Management Service is installed using Typical Setup. The Storage Management Service is available on Microsoft Windows, Red Hat Enterprise Linux, and SUSE Linux Enterprise Server operating systems.
When the Storage Management Service is installed, click the Storage object to view the status and settings for various attached array storage devices, system disks, and so on.
In the case of Storage Management Service, the Storage object action window has the following tab, depending on the user's group privileges: Properties.
Under the Properties tab, you can view the health or status of attached storage components and sensors such as array subsystems and operating system disks.
The left pane of the Preferences home page (where the system tree is displayed on the Server Administrator home page) displays all available configuration options in the system tree window. The options displayed are based on the systems management software installed on the managed system.
The available Preferences home page configuration options are:
Click the General Settings object to set user and DSM SA Connection Service (Web server) preferences for selected Server Administrator functions. The General Settings object action window has the following tabs, depending on the user's group privileges: User and Web Server.
Under the User tab, you can set user preferences, such as the home page appearance and the default e-mail address for the E-mail button.
Under the Web Server tab, you can:
Storage · Properties · User

Click the Server Administrator object to enable or disable access to users with User or Power User privileges and to configure the SNMP root password. The Server Administrator object action window can have the following tab, depending on the user's group privileges: Preferences.
Under the Preferences tab, you can:
Preferences

This chapter provides information about accessing and using the remote access features of BMC/iDRAC and DRAC.
The Dell systems baseboard management controller (BMC)/Integrated Dell Remote Access Controller (iDRAC) monitors the system for critical events by communicating with various sensors on the system board and sends alerts and log events when certain parameters exceed their preset thresholds. The BMC/iDRAC supports the industry-standard Intelligent Platform Management Interface (IPMI) specification, enabling you to configure, monitor, and recover systems remotely.
The DRAC is a systems management hardware and software solution designed to provide remote management capabilities, crashed system recovery, and power control functions for Dell systems.
By communicating with the system’s baseboard management controller (BMC)/Integrated Dell Remote Access Controller (iDRAC), the DRAC can be configured to send you e-mail alerts for warnings or errors related to voltages, temperatures, and fan speeds. The DRAC also logs event data and the most recent crash screen (available only on systems running Microsoft Windows operating system) to help you diagnose the probable cause of a system crash.
The Remote Access Controller provides remote access to an inoperable system, allowing you to get the system up and running as quickly as possible. The Remote Access Controller also provides alert notification when a system is down and allows you to remotely restart a system. Additionally, the Remote Access Controller logs the probable cause of system crashes and saves the most recent crash screen.
You can log in to the Remote Access Controller through the Server Administrator home page or by directly accessing the controller's IP address using a supported browser.
When using the Remote Access Controller, you can click Help for more detailed information about the specific window you are viewing. Remote Access Controller help is available for all windows accessible to the user based on the user privilege level and the specific hardware and software groups that Server Administrator discovers on the managed system.
The following table lists the graphical user interface (GUI) field names and the applicable system, when Server Administrator is installed on the system. Table 10. GUI Field Names And The Applicable System
GUI Field Name Applicable System
Modular Enclosure Modular system
Server Modules Modular system
Main System Modular system

Main System Chassis Non-modular system
For more information on the systems support for remote access devices, see the Dell Systems Software Support Matrix available at dell.com/support/manuals
Server Administrator allows remote, in-band access to event logs, power control, and sensor status information and provides the ability to configure the BMC/iDRAC. To manage BMC/iDRAC and DRAC through the Server Administrator graphical user interface (GUI), click the Remote Access object, which is a subcomponent of the Main System Chassis/ Main System group.
You can perform the following tasks:
You can view BMC/iDRAC or DRAC information based on which hardware is providing the remote access capabilities for the system.
The reporting and configuration of BMC/iDRAC and DRAC can also be managed using the omreport/omconfig chassis remoteaccess command-line interface (CLI) command.
In addition, the Server Administrator Instrumentation Service allows you to manage the Platform Event Filters (PEF) parameters and alert destinations.
You can view basic information about the BMC/iDRAC, IPv4 Address, and DRAC. You can also reset the Remote access controller settings to their default values. To do this:
Click the Modular Enclosure → System/Server Module → Main System Chassis/Main System → Remote Access
The Remote Access page displays the following base information of the system’s BMC:
System Non-modular system · Remote Access Device

To configure the remote access device for communication over a LAN connection:
The LAN Configuration window appears.
NOTE: If your DRAC is configured to the same IP address as another NIC on the same network, an IP address conflict occurs. The DRAC stops responding to network commands until the IP address is changed on the DRAC. The DRAC must be reset even if the IP address conflict is resolved by changing the IP address of the other NIC.
IPv4 Address · IPv6 Address

For 12G systems, the Primary Network options for Remote Management (iDRAC7) NIC are: LOM1, LOM2, LOM3, LOM4, and Dedicated. The Failover Network options are: LOM1, LOM2, LOM3, LOM4, All LOMs, and None.
The dedicated option is available when the iDRAC7 Enterprise License is present and valid.

To configure the BMC for communication over a serial port connection:
The Serial Port Configuration window appears.
In the Terminal Mode Settings window, you can configure terminal mode settings for the serial port.
Terminal mode is used for Intelligent Platform Interface Management (IPMI) messaging over the serial port using printable ASCII characters. Terminal mode also supports a limited number of text commands to support legacy, text-based environments. This environment is designed so that a simple terminal or terminal emulator can be used.
To configure the BMC/iDRAC for communication over a serial over LAN (SOL) connection:
The Serial Over LAN Configuration window appears.

To configure the IPv4 and IPv6 properties using the Additional Configuration tab:
To configure Remote Access Device users using the Remote Access page:
The Remote Access Users window displays information about users that can be configured as BMC/iDRAC users.
The Remote Access User Configuration window allows you to configure a specific BMC/iDRAC user.

To configure the most relevant BMC features, such as Platform Event Filter (PEF) parameters and alert destinations using Server Administrator Instrumentation Service:
The Platform Events window allows you to take individual action on specific platform events. You can select those events for which you want to take shutdown actions and generate alerts for selected actions. You can also send alerts to specific IP address destinations of your choice.
The Set Platform Events window allows you to specify the actions to be taken if the system is to be shut down in response to a platform event.
Shuts down the operating system and initiates system startup, performing BIOS checks and reloading the operating system.
Turns off the electrical power to the system.
Turns the electrical power to the system off, pauses, turns the power on, and reboots the system. Power cycling is useful when you want to reinitialize system components such as hard drives.
Throttles the CPU.

You can also use the Platform Event Filters window to select a destination where an alert for a platform event is to be sent. Depending on the number of destinations that are displayed, you can configure a separate IP address for each destination address. A platform event alert is sent to each destination IP address that you configure.

Server Administrator allows you to view and manage hardware, alert, and command logs. All users can access logs and print reports from either the Server Administrator home page or from its command line interface. Users must be logged in with Administrator privileges to clear logs or must be logged in with Administrator or Power User privileges to e-mail logs to their designated service contact.
For information about viewing logs and creating reports from the command line, see the Dell OpenManage Server Administrator Command Line Interface User's Guide at dell.com/support/manuals
When viewing Server Administrator logs, you can click Help (
) for more detailed information about the specific window you are viewing. Server Administrator log help is available for all windows accessible to the user based on user privilege level and the specific hardware and software groups that Server Administrator discovers on the managed system.
Click a column heading to sort by the column or change the sort direction of the column. Additionally, each log window contains several task buttons that can be used for managing and supporting your system.
The following table lists the Log window task buttons. Table 11. Log Window Task Buttons
Print To print a copy of the log to your default printer.
Export To save a text file containing the log data (with the values of each data field separated by a customizable delimiter) to a destination you specify.
Email To create an e-mail message that includes the log content as an attachment.
Clear Log To erase all events from the log.
Save As To save the log content in a .zip file.
Refresh To reload the log content in the action window data area.
Server Administrator provides the following logs:
Name Description

On Dell PowerEdge 9G and 11G systems, use the hardware log to look for potential problems with your system's
hardware components. the hardware log status indicator changes to critical status (
) when the log file reaches 100 percent capacity. There are two available hardware logs, depending on your system: the Embedded System Management (ESM) log and the System Event Log (SEL). The ESM log and SEL are each a set of embedded instructions that can send hardware status messages to systems management software. Each component listed in the logs has a status indicator icon next to its name. The following table lists the status indicators. Table 12. Hardware Log Status Indicators
Indicates that a component is healthy (normal).
A green check mark (
A yellow triangle containing an exclamation point
Indicates that a component has a warning (noncritical) condition and requires prompt attention.
Indicates that a component has a failure (critical) condition and requires immediate attention.
A red X (
Indicates that a component's health status is unknown.
A question mark (
To access the hardware log, click System, click the Logs tab, and click Hardware.
Information displayed in the ESM and SEL logs includes:
Maintaining The Hardware Log
The status indicator icon next to the log name on the Server Administrator homepage changes from normal status (
to noncritical status (
) when the log file reaches 80 percent capacity. Make sure you clear the hardware log when it reaches 80 percent capacity. If the log is allowed to reach 100 percent capacity, the latest events are discarded from the log.
To clear a hardware log, on the Hardware Log page, click the Clear Log link.
Use the Alert log to monitor various system events. The Server Administrator generates events in response to changes in the status of sensors and other monitored parameters. Each status change event recorded in the Alert log consists of a unique identifier called the event ID for a specific event source category and an event message that describes the event. The event ID and message uniquely describe the severity and cause of the event and provide other relevant information such as the location of the event and the monitored component's previous state.
To access the Alert log, click System, click the Logs tab, and click Alert.

Information displayed in the Alert log includes:
For detailed information about alert messages, see the Server Administrator Messages Reference Guide at dell.com/ support/manuals.
Use the Command log to monitor all of the commands issued by Server Administrator users. The Command log tracks logins, logouts, systems management software initialization, shutdowns initiated by systems management software, and records the last time the log was cleared. The size of the command log file can be specified as per your requirement.
To access the Command log, click System, click the Logs tab, and click Command.
Information displayed in the Command log includes:

Setting Alert Actions For Systems Running Supported Red Hat Enterprise Linux And SUSE Linux Enterprise Server Operating Systems
When you set alert actions for an event, you can specify the action to display an alert on the server. To perform this action, Server Administrator sends a message to /dev/console. If the Server Administrator system is running an X Window System, the messsage is not displayed. To see the alert message on a Red Hat Enterprise Linux system when the X Window System is running, you must start xconsole or xterm -C before the event occurs. To see the alert message on a SUSE Linux Enterprise Server system when the X Window System is running, you must start a terminal such as xterm -C before the event occurs.
When you set Alert Actions for an event, you can specify the action to Broadcast a message. To perform this action, Server Administrator executes the wall command, which sends the message to everybody logged in with their message permission set to Yes. If the Server Administrator system is running an X Window System, the message is not displayed by default. To see the broadcast message when the X Window System is running, you must start a terminal such as xterm or gnome-terminal before the event occurs.
When you set Alert Actions for an event, you can specify the action to Execute application. There are limitations on the applications that Server Administrator can execute. To ensure proper execution:
The command in Example 1 executes the application ps, redirects stdout to the file /tmp/psout.txt, and redirects stderr to the same file as stdout. Example 2: mail -s "Server Alert" admin /tmp/mailout.txt 2>&1
The command in Example 2 executes the mail application to send the message contained in the file /tmp/alertmsg.txtto the Red Hat Enterprise Linux user or SUSE Linux Enterprise Server user, and Administrator, with the subject Server Alert. The file /tmp/alertmsg.txt must be created by the user before the event occurs. In addition, stdout and stderr are redirected to the file /tmp/mailout.txt in case an error occurs.
When specifying alert actions, Visual Basic scripts are not automatically interpreted by the Execute Application feature, although you can run a .cmd, .com, .bat, or .exe file by only specifying the file as the alert action.

To resolve this issue, first call the command processor cmd.exe to start your script. For example, the alert action value to execute an application can be set as follows: c:\winnt\system32\cmd.exe /c d:\example\example1.vbs
where d:\example\example1.vbs is the full path to the script file.
Do not set a path to an interactive application (an application that has a graphical user interface or which requires user input) in the absolute path to the application field. The interactive application may not work as expected on some operating systems.
For security reasons, Windows Server 2008 is configured to not allow interactive services. When a service is installed as an interactive service on Windows Server 2008, the operating system logs an error message to the Windows System log about the service being marked as an interactive service.
When you use Server Administrator to configure Alert Actions for an event, you can specify the action to execute an application. In order for interactive applications to execute properly for an Alert Action, the Dell Systems Management Server Administrator (DSM SA) Data Manager service must be configured as an interactive service. Examples of interactive applications are applications with a graphical user interface (GUI) or that prompt the user for input in some way such as the pause command in a batch file.
When Server Administrator is installed on Microsoft Windows Server 2008, the DSM SA Data Manager service is installed as a non-interactive service which means that it is configured to not be allowed to interact with the desktop by default. This means that interactive applications are not executed properly when executed for an Alert Action. If an interactive application is executed for an Alert Action in this situation, the application is suspended and waits for an input. The application interface/prompt is not visible to you and remains invisible even after the Interactive Services Detection service is started. The Processes tab in the Task Manager displays an application process entry for each execution of the interactive application.
If you need to execute an interactive application for an Alert Action on Microsoft Windows Server 2008, you must configure the DSM SA Data Manager service to be allowed to interact with the desktop and enable interactive services.
To allow interaction with the desktop:
When the DSM SA Data Manager service is restarted with this change, the Service Control Manager logs the following message to the System log: The DSM SA Data Manager service is marked as an interactive service. Enabling the Interactive Services Detection service allows the DSM SA Data Manager service to execute interactive applications properly for an Alert Action.
Once these changes are made, the Interactive services dialog detection dialog box is displayed by the operating system to provide access to the interactive application interface/prompt.
The following table lists all possible Platform Event Filter (PEF) messages along with a description of each event.

Table 13. PEF Alert Events
Fan Probe Failure The fan is running too slow or not at all.
Voltage Probe Failure The voltage is too low for proper operation.
Battery Probe Warning The battery is operating below the recommended charge level.
Battery Probe Failure The battery has failed.
Discrete Voltage Probe Failure The voltage is too low for proper operation.
Temperature Probe Warning The temperature is approaching excessively high or low limits.
Temperature Probe Failure The temperature is either too high or too low for proper operation.
Chassis Intrusion Detected The system chassis has been opened.
Redundancy (PS or Fan) Degraded Redundancy for the fans and/or power supplies has been reduced.
Redundancy (PS or Fan) Lost No redundancy remains for the system's fans and/or power supplies.
Processor Warning A processor is running at less than peak performance or speed.
Processor Failure A processor has failed.
Processor Absent A processor has been removed.
PS/VRM/D2D Warning The power supply, voltage regulator module, or DC to DC converter is pending a failure condition.
PS/VRM/D2D Failure The power supply, voltage regulator module, or DC to DC converter has failed.
Hardware log is full or emptied Either an empty or a full hardware log requires administrator attention.
Automatic System Recovery The system is hung or is not responding and is taking an action configured by Automatic System Recovery.
System Power Probe Warning The power consumption is approaching the failure threshold.
System Power Probe Failure The power consumption has crossed the highest acceptable limit and has resulted in a failure.
Removable Flash Media Absent The removable flash media is removed.
Removable Flash Media Failure The removable flash media is pending a failure condition.
Removable Flash Media Warning The removable flash media pending a failure condition.
Internal Dual SD Module Card Critical The internal dual SD module card has failed.
Internal Dual SD Module Card Warning
The internal dual SD module card is pending a failure condition.
Internal Dual SD Module Card Redundancy Lost
The internal dual SD module card has no redundancy.
Internal Dual SD Module Card Absent The internal dual SD module card is removed.
Event Description

Connection Service Failure
On Red Hat Enterprise Linux, whenSELinux is set to enforced mode , the Dell Systems Management Server Administrator (SM SA) Connection service fails to start. Perform one of the following steps and start this service:
a. setsebool allow_execstack on
You may not be able to login to the managed system if:
a. Thelockdown mode is enabled either while you are logging to the server or while you are logged in to the Server Administrator. For more information on lockdown mode, see the VMware documentation.
b. The password is changed while you are logged in to Server Administrator.
chcon -t unconfined_execmem_t · /opt/dell/srvadmin/sbin/dsm_om_connsvcd

c. You log in to Server Administrator as a normal user without administrator privileges. For more information, see the VMware documentation on assigning the role.
You can fix a faulty installation by forcing a reinstall and then performing an uninstall of Server Administrator.
To force a reinstall:
The following table lists the services used by Server Administrator to provide systems management information and the impact of these services failing. Table 14. OpenManage Server Administrator Services
Service Name Description Impact of Failure Recovery Mechanism Severity
Windows: SM SA Connection Service Linux: dsm_om_connsvc (This service is installed with the Server Administrator Web server.)
Provides remote/local access to Server Administrator from any system with a supported Web browser and network connection.
Users are not able to login to Server Administrator and perform any operation through the Web user interface. However, CLI can still be used.
Restart the service Critical
Runs inventory collector at startup to perform a software inventory of the system to be consumed by Server Administrator’s SNMP and CIM providers to perform a remote software update using Dell System Management Console and Dell IT Assistant (ITA).
Software updates are not possible using ITA. However, the updates can still be done locally and outside of Server Administrator using individual Dell Update packages. Updates can still be performed using 3rd party tools (for example, MSSMS, Altiris and Novell ZENworks).
Restart the service Warning

Service Name Description Impact of Failure Recovery Mechanism Severity
NOTE: If the 32-bit compatibility libraries are not installed on a 64-bit Linux system, the shared services fail to start the inventory collector and display the error message libstdc++.so.5 is required to run the Inventory Collector. The srvadmin-cm.rpm provides the binaries for the inventory collector. For the list of RPMs that srvadmin-cm depends on, see the OpenManage Server Administrator Installation Guide available at dell.com/support/manuals
Windows: SM SA Data Manager Linux: dsm_sa_datamgr d (hosted under dataeng service) (This service runs on the managed system.)
Monitors the system, provides rapid access to detailed fault and performance information and allows remote administration of monitored systems, including shutdown, startup, and security.
Users are not able to configure/view the hardware level details on GUI/CLI without these services running.
Restart the service Critical
SM SA Event Manager (Windows) Linux: dsm_sa_eventmg rd (hosted under dataeng service) (This service runs on the managed system.
Provides operating system and file event logging service for systems management and is also used by event log analyzers.
If this service is stopped, event logging features do not function properly
Restart the service Warning
Data Engine Linux SNMP Interface
SNMP get/set /trap request is not functional from a management station.
Restart the service Critical
The Storage Management Service provides storage management information and advanced features for configuring a local or remote storage attached to a system.
Users are unable to perform storage functions for all supported RAID and non-RAID controllers.
Restart the service Critical

This section lists the frequently asked questions about OpenManage Server Administrator.
This issue is due to VMware stand-alone license (SAL) key. For more information, see the knowledge base article at kb.vmware.com/kb/kb1026060
After adding a VMware ESX 4.0 U3 and ESX 4.1 U2 operating system to the Active Directory domain, an Active Directory user must:
a. Log in to Server Administrator on the system running the VMware ESX 4.0 U3 and ESX 4.1 U2 operating system and restart the DSM SA Connection Service.
b. Log in to the Remote Node while using the VMware ESX 4.0 U3 and ESX 4.1 U2 operating system as a Remote Enablement Agent. Wait for approximately 5 minutes for the sfcbd process to add the permission to the new user.
To install Server Administrator, you must have Administrator level privileges. Power Users and Users do not have permission to install Server Administrator.
For systems that are running Server Administrator version 4.3, you must upgrade to a 6.x version and then to version 7.x. For systems running a version prior to 4.3, you must upgrade to version 4.3, then to a 6.x version, and then to version 7.x (x indicates the version of Server Administrator you want to upgrade to).
Log on to: support.dell.com → Enterprise IT → Manuals → Software → Systems Management → OpenManage Server Administrator.
The latest documentation version reflects the version of OpenManage Server Administrator available.
After logging in to Server Administrator, navigate to Properties → Summary. You can find the version of Server Administrator installed on your system in the Systems Management column.
Yes, you can set your preferred https port. Navigate to Preferences → General Settings → Web Server →HTTPS Port
Instead of Use default, select the Use radio button to set your preferred port.
No, Server Administrator does not support any of these operating systems.

No, Server Administrator is not designed to send e-mails when there is a problem.
ITA communicating with Linux systems:
SNMP is required on the Linux system for discovery, status polling, and inventory.
Software updates are done through an SSH session and secure FTP and root level permissions/credentials are required for this discrete action and asked for when the action is setup or requested. Credentials from the discovery range are not assumed.
ITA communicating with Windows systems:
For servers (systems running Windows Server operating systems), the system may be configured with either or both of SNMP and CIM for discovery by ITA. Inventory requires CIM.
Software updates, as in Linux, are not related to discovery and polling and the protocols used.
Using Administrator level credentials asked for at the time the update is scheduled or performed, an administrative (drive) share is established to a drive on the target system, and file(s) copying from somewhere (possibly another network share) is done to the target system. WMI functions are then invoked to execute the software update.
As Server Administrator is not installed on Clients/Workstations, so CIM discovery is used when the target is running the OpenManage Client Instrumentation.
For many other devices such as network printers, SNMP is the standard to communicate with (primarily discover) the device.
Devices such as EMC storage have proprietary protocols. Some information about this environment can be gathered from looking at the ports used tables in the OpenManage documentation.
No, there are no plans for SNMP v3 support.
Yes, an underscore character in the domain name is invalid. All other special characters (except the hyphen) are invalid too. Use case-sensitive alphabets and numerals only.
If you do not select the Active Directory check box, you will only have access that is configured in the Microsoft Active Directory. You cannot log in using the Extended Schema Solution in Microsoft Active Directory.
This solution enables you to provide access to Server Administrator; allowing you to add/control Server Administrator users and privileges to existing users in your Active Directory software. For more information, see "Using Microsoft Active Directory" in the Dell OpenManage Server Administrator Installation Guide available at dell.com/support/manuals
For authentication, the contents of the files /etc/pam.d/openwsman and /etc/pam.d/sfcb, on the managed node, must be replaced with:
For 32-bit: auth required pam_stack.so service=system-auth auth required /lib/security/ pam_nologin.so account required pam_stack.so service=system-auth