The M910 is ideal for the demanding applications at the core of most data centers, such as large databases, virtualization and messaging infrastructure.

Dell, PowerEdge, EqualLogic, PowerVault, OpenManage, and ReadyRails are trademarks of Dell, Inc. Citrix® and XenServer™ are trademarks of Citrix Systems, Inc. and/or one or more of its subsidiaries, and may be registered in the United States Patent and Trademark Office and in other countries. Intel, Xeon, and Speedstep are registered trademarks and MMX and Core are trademarks of Intel Corporation in the U.S. and other countries. HP and COMPAQ are trademarks of Hewlett-Packard Company. Broadcom is a registered trademark and NetXtreme is a trademark of Broadcom Corporation and/or its affiliates in the United States, certain other countries and/or the EU. CommVault Galaxy and Simpana are registered trademarks of CommVault Systems, Inc. InfiniBand is a registered trademark and service mark of the InfiniBand Trade Association. Matrox is a registered trademark of Matrox Electronic Systems Ltd. Microsoft, Windows, Windows Server, SQL Server, and BitLocker, and Hyper-V are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries. Mellanox is a registered trademark of Mellanox Technologies, Inc. and ConnectX, InfiniBlast, InfiniBridge, InfiniHost, InfiniRISC, InfiniScale, and InfiniPCI are trademarks of Mellanox Technologies, Inc. Novell is a registered trademarks of Novell, Inc., in the United States and other countries. PCI Express is a registered trademark of PCI-SIG. Red Hat is a registered trademark of Red Hat, Inc. in the United States and other countries. Linux is a registered trademark of Linus Torvalds. Symantec and Backup Exec are trademarks owned by Symantec Corporation or its affiliates in the U.S. and other countries. QLogic and PathScale are registered trademarks of Qlogic Corporation. VMware is a registered trademark and vSphere is a trademark of VMware, Inc. in the United States and/or other jurisdictions. vRanger, vFoglight, vConverter, Vizioncore vOptimizer, and Vizioncore vEssentials are trademarks of Vizioncore Inc. Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products. Dell disclaims proprietary interest in the marks and names of others.
©Copyright 2010 Dell Inc. All rights reserved. Reproduction or translation of any part of this work beyond that permitted by U.S. copyright laws without the written permission of Dell Inc. is unlawful and strictly forbidden.
Revision 1 September 2010



8 Chipset 25 8.1 Intel 7500 I/O Hub (IOH) 25 8.2 IOH QuickPath Interconnect (QPI) 25 8.3 PCI EXPRESS GENERATION 2 25 8.4 Direct Media Interface (DMI) 25 8.5 Intel I/O Controller Hub 10 (ICH10) 25 8.6 PCI Express Mezzanine Connectors 26 9 BIOS 27 9.1 Overview 27 9.2 Supported ACPI States 27 10 Embedded Gigabit Ethernet Controllers on Motherboard (LOM) 28 11 I/O Mezzanine Card Options 29 11.1 Overview 29 11.2 Options 29 12 Storage 30 12.1 Drives 30 12.2 Hard Disk Drive Carriers 30 12.3 Empty Drive Bays 30 12.4 Diskless Configuration Support 30 12.5 RAID Configurations 31 12.6 Storage Controllers 31 12.6.1 SATA Repeater 31 12.6.2 PERC6/i 32 12.6.3 PERC H200 32 12.6.4 PERC H700 32 12.7 LED Indicators 32 12.8 Optical Drives 32 13 Video (PCI Video) 33 14 Rack Information 34 15 Operating Systems 35 16 Virtualization 36 16.1 Overview 36 16.2 Advanced Infrastructure Manager by Scalent 36 16.3 Vizioncore 37 17 Systems Management 38 17.1 Overview 38 17.2 Server Management 38 17.3 Embedded Server Management 39 17.4 Lifecycle Controller and Unified Server Configurator 39 17.5 The iDRAC6 Enterprise 40 17.6 Chassis Management Controller (CMC) 41 18 Peripherals 42 18.1 USB peripherals 42 18.2 External Storage 42
Table 1. Product Comparisons 6 Table 2. Product Features 10 Table 3. Operating and Storage Conditions 15 Table 4. Typical Configuration Used in Testing 16

Table 5. Processor Cache Sizes (Package LGA1567) 18 Table 6. Supported Processors 19 Table 7. PowerEdge M910 Sparing and Mirroring 22 Table 8. Supported Memory Configurations 24 Table 9. RAID Configurations 31 Table 10. Storage Controllers Supported on the M910 31 Table 11. Supported Video Modes 33 Table 12. Virtualization Software 36 Table 13. Unified Server Configurator Features and Description 39 Table 14. Features List for BMC, iDrac, and vFlash 40 Table 15. Industry Standards and URLs 43
Figure 1. M1000e 12 Figure 2. Internal Module View 13 Figure 3. Diagram of FlexMem Bridge Routing 20 Figure 4. Memory Diagram 21 Figure 5. PowerEdge M910 2P Mirroring 23 Figure 6. M910 4P Mirroring 23 Figure 7. 2.5‖ HDD Carrier 30

1.1 Overview
The Dell™ PowerEdge™ M-Series blade servers are designed to help cut operating expenses through energy efficiency, scalability, product flexibility, and efficient use of data center space.
The PowerEdge M910 provides significant performance and reliability in a scalable, full-height, four- socket blade server, allowing the deployment of large Enterprise-class applications as well as the ability to support heavy virtualization or workload consolidation in maximum density.
When combined with Dell’s world-class storage, management, and support offerings, the result is a total enterprise solution that can help you optimize your IT environment and expenses.
The PowerEdge M910 was designed to meet the needs of nearly any IT infrastructure or environment. Built with powerful Intel® Xeon® processor 7500 series and advanced systems management capabilities, the M910 is ideal for the demanding applications at the core of most data centers, such as large databases, virtualization, and messaging infrastructure.
Memory is a critical component for performance, especially for heavy virtualization and high-end database needs. With this in mind, the PowerEdge M910 was designed with 32 DIMM slots allowing up to 512GB of ECC DDR3 RAM to be supported, allowing these memory-intensive applications to have ample resources at their disposal.
Many servers may be able to take advantage of the large memory support that modern architectures provide, but only Dell offers FlexMem Bridge technology, which allows the M910 to seamlessly scale from 4GB to 512GB of DDR3 RAM in either two-socket or four-socket configurations. This patent- pending technology allows Dell to deliver a unique platform that can seamlessly scale as customer and application needs dictate, without having to ―rip and replace‖ existing server infrastructure.
In addition to allowing significant memory and processor scaling capabilities, the compact form- factor of Dell blades allows the ability to scale down the amount of space that your core application servers require. By utilizing the PowerEdge M910, you can deploy up to eight next generation 4- socket servers in only 10U of rack space, which is less than 1/3 of the space required using traditional 4U four-socket rack servers.
With the PowerEdge M910, Dell continues its unrelenting focus on reliability. The PowerEdge M910 utilizes the redundant power, cooling, and networking infrastructure provided by the Dell M1000e Blade enclosure. The PowerEdge M910 itself incorporates improvements and features for maximum protection against potential downtime, such as the ability to support three fully redundant fabrics per blade and the inclusion of a dual-media redundant embedded hypervisor.
The PowerEdge M910 also utilizes Intel Xeon 7500 series processors which are designed to automatically monitor, report, and recover from hardware errors in order to maintain data integrity and keep mission-critical services online.
As with all Dell PowerEdge servers, the M910 is manufactured with our ―one-touch‖ factory build process. This process is designed to ensure just one person is responsible for the entire server build, resulting in greater quality control. In addition, every fully configured Dell server is tested (and re- tested) before it leaves the factory to ensure maximum reliability.
Powerful · Scalable · Reliable

Product documentation is available at support.dell.com. Information for the chassis can be found in the PowerEdge M1000e Technical Guide.
Table 1. Product Comparisons
Feature /Spec M910 M710 R810 R910
Processor 4 Socket Intel® Xeon® processor 6500 and 7500 series
2 Socket Intel® Xeon® processor 5500 series
4 Socket Intel® Xeon® processor 6500 and 7500 series
2 or4 Socket Intel® Xeon® 7500 Series
Front Side Bus Four Intel® QuickPath Interconnect (QPI) links
Two Intel® QuickPath Interconnect (QPI) links
Four Intel® QuickPath Interconnect (QPI) links
Up to 6.4 GT/s Intel® QuickPath Interconnect (QPI) links
# Proc Sockets 2/4 2 2/4 2/4/6
Max # Cores per Socket
2S w/ up to16 cores
Up to 4 2S w/ up to16 cores
2S w/ up to16 cores
4S w/ up to 32 cores
4S w/ up to 32 cores
4S w/ up to 32 cores
L2/L3 Cache L2 cache:1.5MB or 2MB L3 cache: 12MB, 18MB or 24MB (shared)
4MB and 8MB L2 cache:1.5MB or 2MB L3 cache: 12MB, 18MB or 24MB (shared)
Chipset Intel® 7500 Intel® 5520 Intel® 7500 Intel® 7500
DIMMs 32 x DDR3 18 DDR3 32 x DDR3 64 x DDR3
Min/Max RAM 4GB–512GB 1GB–192GB 4GB–512GB 4GB – 1TB
Form Factor Full Height Blade, Dual Slot
Full Height Blade, Dual Slot
HD Bays (2.5” only)
2 4 6 16
HD Types SAS/SSD
Integrated Standard HD Controller
H200/H700 (factory installed) and PERC6 as custom kit
H200/H700
H200/H700 Integrated controller (Battery backup for the H700 and PERC6 options only)
SAS6/iR PERC6i with RAID battery
PERC H800 or 6Gbps SAS
PERC H800 or 6Gbps SAS
Availability Hot-swap hard drives Hot-swap redundant power and cooling ECC memory Single Device Data Correction (SDDC) Supports memory demand and patrol scrubbing High-availability failover cluster support
Hot-swap hard drives Hot-swap redundant power and cooling ECC memory Single Device Data Correction (SDDC) Supports memory demand and patrol scrubbing High-availability failover cluster support
Hot-swap hard drives Hot-swap redundant power and cooling ECC memory Single Device Data Correction (SDDC) Supports memory demand and patrol scrubbing High-availability failover cluster support
Hot-swap hard drives Hot-swap redundant power and cooling ECC memory Single Device Data Correction (SDDC) supports memory demand and patrol scrubbing High availability
2U Chassis, Rack · 4U chassis, Rack · Optional HD Controller

Feature /Spec M910 M710 R810 R910
iDRAC6 Enterprise CMC (on M1000e)
iDRAC6 Enterprise (Both) standard CMC (on M1000e)
iDRAC6 Express iDRAC6 Enterprise Optional
iDRAC6 Express iDRAC6 Enterprise Optional
Mezz Slots 4 x8 PCIe Mezzanine Cards
1 x 4 and 3 x 8 PCIe Mezzanine Cards
6 x PCIe 5 x 8 1 x 4
7 PCIe Gen2 slots (2x4, 4 x8 + 1x16) Optional: 10 PCI e Gen2 (6x4, 4x8) Slot 5 is Gen1
NIC/LOM 4 x TOE – iSCSI offload 4 x TOE with optional iSCSI offload
4 x LOM (5709)
1GbE or 10Gp SFP+ embedded NIC options 4-port (4x1GbE) embedded NIC Broadcom 5709c Or 4-port (2x10gb SPF+ & 2x1GbE) Embedded NIC Broadcom 57711 + Broadcom 5709c
USB 3 x External USB 2.0 ports at front bezel 1 x Internal USB port
3 x External USB 2.0 ports at front bezel 1 x Internal USB port
2 ports in the front 4 ports in the rear 2 in the rear 2 in the front 1
SD Card 2 x Internal SD slot 1 for Persistent Storage 1 for Lifecycle controller on iDRAC (can also be configured as redundant SD cards - RIPS)
1 x Internal SD slot 1 for Persistent Storage 1 for Lifecycle controller on iDRAC
2 x Internal SD slot 1 for Persistent Storage 1 for Lifecycle controller on iDRAC
2 x Internal SD slot 1 for Persistent Storage 1 for Lifecycle controller on iDRAC
Power Supplies See PowerEdge M1000e Technical Guide
See PowerEdge M1000e Technical Guide
2 x 1100W 4 x 750w (Energy Smart) Or 4 x 1100W (High output)
Fans See PowerEdge M1000e Technical Guide
See PowerEdge M1000e Technical Guide
Redundant cooling Redundant cooling
Chassis See PowerEdge M1000e Technical Guide
See PowerEdge M1000e Technical Guide
Server Management · Rack Rack

2.1 Overview
The PowerEdge M910 server includes the following new features:
Intel Xeon Processor 7500 Series (4s) and Intel Xeon Processor 6500 Series (2s) 4-, 6-, and 8- core processors Intel 7500 Chipset FlexMem Bridge IO Hub (IOH) with Intel® QuickPath Architecture DDR3 memory PCI Express® Generation 2 Optional Redundant SD media for embedded hypervisor iDRAC6 Express
The processor features up to eight-core processing to with maximize performance (expected up to 3.8x performance improvements) and performance/watt and significant energy efficiency improvements for datacenter infrastructures and highly dense deployments. Additionally, the Intel Xeon processor 6500 and 7500 series features the Intel® 64 Architecture for flexibility in 64-bit and 32-bit applications and operating systems.
See Section 8 for detailed information in the Intel 7500 chipset.
The PowerEdge M910 also introduces a new, Dell patent-pending, technology which will allow flexibility in processor and memory scalability—FlexMem Bridge. The FlexMem Bridge allows the full amount of addressable DIMMs on 4-Socket systems with Intel Xeon processor 7500 and 6500 series to be accessed, even when only 2 of the processors are in place, in a completely passive solution (no active components).
The Intel QuickPath Architecture consists of serial point-to-point interconnects for the processors and the system IOH. The M910 has a total of eight QuickPath Interconnects (QPI) lines: six links connecting the processors and two links connection processors 1 and 2 with the IOH.
The M910 uses DDR3 memory which provides a high-performance, high-speed memory interface capable of low latency response and high throughput. The M910 supports Registered ECC DDR3 DIMMs (RDIMMs).
The DDR3 memory interface consists of 8 Intel Scalable Memory Buffers (SMBs), each or which has two DDR3 memory channels. Each channel supports up to two RDIMMs for single/dual/quad rack. By limiting to two DIMMs per DDR channel, the system can support quad-rank DIMMs at 1067MHz.

PCI Express is a serial point‐to‐point interconnect for I/O devices. PCIe Gen2 doubles the signaling bit rate of each lane from 2.5 Gb/s to 5 Gb/s. Each of the PCIe Gen2 ports is backwards‐compatible with Gen1 transfer rates.
The Internal SD Module is dedicated for an SD Flash Card with embedded Hypervisor for virtualization. The SD Flash Card contains a bootable OS image for virtualized platforms. The persistent storage solution on the M910 allows for redundant SD cards.
The iDRAC6 Express feature set is a managed persistent storage space for server provisioning data. It consists of 1 GB flash and vFlash (an optional externally accessible SD card). vFlash offers the hot- swap portability and increased storage capacity benefits of SD while still being managed by the system.

3.1 Overview
The PowerEdge M910 is an innovative blade design that allows scaling from 2 to 4 sockets (no single or 3 socket support) based on a new generation of Intel four-socket enhanced processors, RAM, and management while still taking advantage of the M1000e chassis architecture. Along with the M1000e chassis, the PowerEdge M910 server leads the industry in high speed, redundant IO throughput and power efficiency with more RAM slots in the 2-socket space.
Table 2. Product Features
1 GB means 1 billion bytes and TB equals 1 trillion bytes; actual capacity varies with preloaded material and operating environment and will be less.


4.1 Overview
The M910 is a full height blade server that requires an M1000e chassis (shown in Figure 1) to operate.

Figure 1. M1000e
It occupies 2 slots in the M1000e rack chassis for a maximum of 8 blades in one M1000e chassis. It can be mixed with other existing Dell blades and is designed to mix with possible future half-height- double-wide and full-height-double-wide blades. Some highlights are:
Refer to the PowerEdge M1000e Technical Guide for information on fans, power and power supply, racks, security, and other chassis information.
A view of the internal module is shown in Figure 2. See Opening and Closing the Blade in the Dell PowerEdge Modular Systems Hardware Owner’s Manual for more information.


Figure 2. Internal Module View
Configurable client IP address range for clients connecting to iDRAC6.
The blade module includes a latch for the cover. See Opening and Closing the Blade in the Dell PowerEdge Modular Systems Hardware Owner’s Manual for more information.
The TPM is used to generate/store keys, protect/authenticate passwords, and create/store digital certificates. TPM can also be used to enable the BitLocker™ hard drive encryption feature in Windows Server 2008. TPM is enabled through a BIOS option and uses HMAC-SHA1-160 for binding. TCM is available in China.

Through the CMC, the front USB’s and power button can be disabled so as to not allow any control of the system from the front of the blade.
The M910 supports the following USB devices:
A replaceable coin cell CR2032 3V battery is mounted on the planar to provide backup power for the Real-Time Clock and CMOS RAM on the ICH9 chip.
The planar contains a serial EEPROM to contain FRU information including Dell part number, part revision level, and serial number.

5.1 Overview of Operating and Storage Conditions
Table 3. Operating and Storage Conditions
10o to 35o C (50o to 95o F) with a maximum temperature gradation of 10o C per hour NOTE: For altitudes above 2950 feet, the maximum operating temperature is derated 1oF/500ft
Storage –40o to 65oC (–40o to 149oF) with a maximum temperature gradation of 20oC per hour
Operating 20% to 80% (noncondensing) with a maximum humidity gradation of 10% per hour
Storage 5% to 95% (noncondensing) with a maximum humidity gradation of 10% per hour
Operating 0.26 Grms at 5–350 Hz in operational orientations
Storage 1.54 Grms at 10–250 Hz in all orientations
Operating Half sine shock in all operational orientations of 31 G +/- 5% with a pulse duration of 2.6 ms +/- 10%
Storage Half sine shock on all six sides of 71 G +/– 5% with a pulse duration of 2 ms +/– 10%
-15.2m to 3048 m (-50 to 10,000 ft) Note: For altitudes above 2950 ft, the maximum temperature is derated 1o F/550 ft
Storage -16 to 10,600 m (-50 to 35,000 ft)

Adherence to Dell’s high sound quality standards. Sound quality is different from sound power level and sound pressure level in that it describes how humans respond to annoyances in sound, like whistles, hums, etc. One of the sound quality metrics in the Dell specification is prominence ratio of a tone, and this is listed in the table below.
Acoustical Performance of Typical Configuration: When installed in the M1000e blade chassis, typical configuration2 (shown in Table 4of M910 blade results in the following idle acoustical performance in 23±2° C ambient:
LwA-UL3 = 8.1 bels and no prominent tones4
Table 4. Typical Configuration Used in Testing

2 Typical configuration means projected average quantity, type, capacity, speed, etc., of components. Configuration for which data reported is listed in Table 4. 3 LwA – UL is the upper limit sound power level (LwA) calculated per section 4.4.2 of ISO 9296 (1988) and measured in accordance to ISO 7779 (1999). 4 Prominent tone: Criteria of D.5 and D.8 of ECMA-74 9th ed. (2005) are followed to determine if discrete tones are prominent. The system is placed in a rack with its bottom at 75 cm from the floor. The acoustical transducer is at front bystander position, ref ISO7779 (1999) Section 8.6.2.

The M910 thermal solution includes:
Optimized airflow impedance for individual blade and chassis level airflow balancing Custom air baffling directs airflow through the components to maintain proper cooling Custom-designed heat sinks maintain CPU, IOH, and Intel 7500 chip temperatures within thermal design targets Highly Optimized Fan Control Algorithm such as the following:
o Base fan speeds are a function of hardware configuration and ambient temperature
to minimize airflow for a given environment o PID control algorithms are used for both CPU and DIMMs to maintain appropriate
thermal margin o Double refresh switching allows for DIMM temperature excursions up to 95°C while
maintaining performance and thermal design targets as follows:
The M910 thermal algorithm monitors the thermal sensor on each DIMM to maintain DIMM temperatures below the typical 85°C specification in normal operating conditions. Under extreme operating conditions, the thermal algorithm can switch the DIMMs into Double Refresh mode allowing an additional 10°C of thermal headroom. In Double Refresh mode, DIMMs are allowed to operate as high as 95°C.
One of the main features of blade servers is enhanced power efficiency. The PowerEdge M910 achieves higher power efficiency by implementing the following features:

6.1 Overview
The Intel Xeon processor 6500 and 7500 series 4S (Expandable Processor) is the microprocessor designed specifically for servers and workstation applications. The processor features quad-core processing to maximize performance and performance/watt for data center infrastructures and highly dense deployments. The Intel Xeon processor 6500 and 7500 series also features Intel® Core™ micro-architecture and Intel® 64 architecture for flexibility in 64-bit and 32-bit applications and operating systems. The Intel Xeon processor 6500 and 7500 series supports all Streaming SIMD Extensions (including SSE2, SSE3, and SSE4) and Intel 64 instruction.
The Intel Xeon processor 6500 and 7500 series 4S (Expandable Processor) uses a 1567-pins Land Grid Array (LGA1567) package that plugs into a surface-mount socket. The M910 provides support for two or four processors.
Table 5. Processor Cache Sizes (Package LGA1567)
L1 cache size 32 KB instruction (32 KB data)
L2 cache size 1.5MB or 2MB
L3 cache size 12MB, 18MB or 24MB (shared)
Key features of the Intel Xeon processor 6500 and 7500 series include:
Cache Size

Table 6. Supported Processors

The PowerEdge M910 is designed to support either a dual CPU configuration with FlexMem Bridge or a 4 CPU configuration. In either configuration, all IO and memory is available in the system. While not formally supported, single CPU configurations with a processor installed in CPU1 will allow the system to boot for diagnostic purposes.
The Intel Xeon processor 6500 series is for 2-socket configurations only and cannot be upgraded to a 4-socket configuration.
In a 4-CPU configuration, the PowerEdge M910 uses only one memory controller per CPU. This single controller connects to two memory buffers via Intel SMI links. Each memory buffer in turn connects to four DDR3 DIMMs. In a typical Intel Xeon processor 6500/7500 series configuration, only the

memory buffers associated with the two populated sockets would be connected, and therefore only 16 DIMMs would be accessible.
To overcome this limitation with 2 CPUs, the M910 uses the FlexMem Bridge which allows CPU1 and CPU2 to connect to the memory of their respective adjacent sockets (CPU3 and CPU4). The FlexMem Bridge provides the following:
Two pass-through links for SMI One pass-through link for QPI
The pass-through SMI links connect the two installed CPU’s to additional SMIs, therefore the CPU’s will have the following memory attached:
CPU1 will have access to DIMMs [A1:A8], plus DIMMs [C1:C8] (those normally associated with CPU3) CPU2 will have access to DIMMs [B1:B8], plus DIMMs [D1:D8] (those normally associated with CPU4)
The pass-through QPI link on the FlexMem Bridge provides increased performance for a 2P configuration because it allows 2 full-bandwidth QPI links between CPU1 and CPU2 as opposed to a single link. Figure 3 depicts the interconnection between the CPU sockets as well as connections internal to the FlexMem Bridges. The FlexMem Bridges are only supported in sockets 3 and 4.
IOH
PROC2
Figure 3. Diagram of FlexMem Bridge Routing
Modern processors are capable of tremendous workloads, and many types of utilization patterns such as virtualization often run into memory capacity issues well before the processors reach a saturation point. FlexMem Bridge technology was designed to assist those customers that have workloads that are memory intensive.
Customers who scale their workloads in the future to a point where they would need additional processing power can simply replace the FlexMem Bridge with additional processors to meet those needs.
Due to power limitations, the PowerEdge M910 will only support two X7560 (130W) processors. In an upgrade for a server with two 130W CPUs, the CPUs and the heatsink must be changed to the 95W or 105W CPUs. If the server has only the 95W or 105W CPUs, CPUs can simply be swapped out.

7.1 Overview
The PowerEdge M910 uses DDR3 memory providing a high-performance, high-speed memory interface capable of low latency response and high throughput. The PowerEdge M910 supports Registered ECC DDR3 DIMMs (RDIMM) only. Each DDR3 DIMM is driven by the Intel® 7500 Scalable Memory Buffer (Intel® 7500 SMB). A memory buffer has two DDR3 channels off it. Each of these channels can support up to 2 DIMMs running at 1067MHz (or slower) speeds. Intel® 7500 SMB will support single-, dual-, and quad-rank DIMMs. Up to four 2 GB, 4 GB, 8 GB, and 16 GB RDIMMs are supported per channel, for a total of up to 512 GB. Single-rank, dual rank, and quad-rank RDIMMs are supported. Across CPUs, DIMM populations can be different on the memory for each CPU as long as the population rules for each CPU socket are followed. Additionally, all CPU sockets operate in the same RAS mode and are set up with the same memory timing parameters.
4-socket platform capability (64 DIMMs):
Up to 16 DDR3 DIMMs per socket through use of up to four Scalable Memory Buffers Support for up to 16GB DDR3 DIMMs 1TB with 16GB DIMMS
Memory types supported:
1066MHz DDR3 (800 & 1333MHz availability depends on OEM validation) Registered (RDIMM) Single-rank (SR), dual-rank (DR), quad-rank (QR)
Actual system memory speed depends on specific processor capabilities:
6.4GT/s SMI link speed capable of running memory speeds up to 1066Mhz 5.86GT/s SMI link speed capable of running memory speeds up to 978Mhz 4.8GT/s SMI link speed capable of running memory speeds up to 800Mhz

Figure 4. Memory Diagram

If DIMMs of different speeds are mixed, all channels operate at the fastest common frequency. UDIMMs are not supported. The first DIMM slot in each channel is color‐coded with white ejection tabs for ease of identification. The M910’s DIMM sockets are placed 0.40‖ apart, center‐to‐center, to provide enough space for sufficient airflow to cool stacked DIMMs. DIMMs must be installed in each channel starting with the DIMM farthest from the processor (DIMM 1). Population order is identified by silkscreen and a label. The order is dependent on the memory configuration used. See Table 8 for DIMM naming and population ordering.
For information, see System Memory in the Dell PowerEdge Modular Systems Hardware Owner’s Manual.
The Intel 7500 SMB supports one Intel Scalable Memory Interconnect (Intel SMI), 2 DDR3 channels, and 1 SMBus slave interface at 100KHz. It does not support the repeater functionality. Target package size is 19.5mm x 24.5mm with 0.8 mm pitch. Intel SMI supports link speeds of 4.8, 5.86, and 6.4 GT/s with 11 Southbound lanes (9 data + 1 CRC + 1 spare) and 14 Northbound lanes (12 data + 1 CRC + 1 spare).
The DDR3 interface supports x4 and x8 single-rank, dual-rank, and quad-rank RDIMMs, and up to 2 RDIMMS per channel. Each DDR3 channel supports a maximum of 8 ranks. DDR3 speeds are 800, 978, and 1066 MHz. DRAM technology comes in 1 and 2Gb sizes. DIMM capacity is 1, 2, 4, 8, or 16GB (16GB with QR DIMMS only).
The Intel Xeon processor 6500 and 7500 series supports high-availability memory modes including rank and DIMM sparing as well as memory mirroring. The M910 supports rank sparing only and mirroring as shown in Table 7.
Table 7. PowerEdge M910 Sparing and Mirroring
Type Rules enforced 1P 2P 4P Rules Enforced
Rank The capacity of the spare rank must be greater than that of any other rank on the channel
No support Inter-socket (hemisphere mode enabled)
32 DIMM only, Mirrored must match
For information, see System Memory in the Dell PowerEdge Modular Systems Hardware Owner’s Manual.
Sparing Mirroring · Inter- socket

For mirroring, the M910 will support 2P/4P configurations with 32 DIMMs only. When mirroring is enabled, only half of the physical memory will be visible to the system software. A full copy of the memory is maintained, and in the event of an uncorrectable error, the system will switch over to the mirrored copy. In 2P mode, the mirroring will be inter-node with hemisphere mode enabled. In this case, the memory controller (MBox) of CPU1 is mapped to the corresponding MBox of CPU2. The figure below depicts the mirroring logic for 2P configurations. A, B, C and D represent the DIMM socket groups.

DIMM1
DIMM2
DIMM3
DIMM4
DIMM5
DIMM6
DIMM7
DIMM8
D
MBOX0
MBOX0
CPU1
CPU2
MBOX1
MBOX1
DIMM1 DIMM2 DIMM3 DIMM4 DIMM5 DIMM6 DIMM7 DIMM8
DIMM1
DIMM2
DIMM3
DIMM4
DIMM5
DIMM6
DIMM7
DIMM8
B
Figure 5. PowerEdge M910 2P Mirroring
For 4-processor configurations, the PowerEdge M910 will also support mirroring in the inter-socket mode (note that intra-socket is not possible in 4P because each CPU has only one MBox connected to memory buffers). In this 4P case, the memory on CPU1 will be mirrored with memory on CPU3, while memory on CPU2 is mirrored with memory on CPU4. Figure 6 depicts the mirroring logic for 2P configurations. A,B,C and D represent the DIMM socket groups.

MBOX0
MBOX0
CPU1
CPU2
MBOX1
MBOX1
DIMM1
DIMM2
DIMM3
DIMM4
DIMM5
DIMM6
DIMM7
DIMM8
B
DIMM1
DIMM2
DIMM3
DIMM4
DIMM5
DIMM6
DIMM7
DIMM8
D
MBOX0
MBOX0
CPU3
CPU4
MBOX1
MBOX1
DIMM1 DIMM2 DIMM3 DIMM4 DIMM5 DIMM6 DIMM7 DIMM8
Figure 6. M910 4P Mirroring

config # Technology DIMM Capacity Qty of DIMMs
1 RDIMM 1 GB 4 4 GB 2 N N 1
2 RDIMM 1 GB 8 8 GB 4 N N 1
3 RDIMM 2 GB 8 16 GB 2 & 4 N N 2
4 RDIMM 4 GB 8 32 GB 2 & 4 N N 4
5 RDIMM 4 GB 24 96 GB 2 & 4 Y N 4
6 RDIMM 4 GB 24 96 GB 2 & 4 Y N 4
7 RDIMM 4 GB 32 128 GB 2 & 4 Y Y 4
8 RDIMM 4 GB 32 128 GB 2 & 4 Y Y 4
9 RDIMM 8 GB 16 128 GB 2 & 4 Y N 4
10 RDIMM 8 GB 24 192 GB 2 & 4 Y N 4
11 RDIMM 16x4GB + 16x8GB 32 192 GB 2 & 4 Y Y 4
12 RDIMM 8 GB 32 256 GB 2 & 4 Y Y 4
13 RDIMM 24x4GB + 8x8GB 32 160GB 2 & 4 Y Y 4
14 RDIMM 16GB 8 128GB 2 & 4 Y N 4
15 RDIMM 16GB 16 256GB 2 & 4 Y N 4
16 RDIMM 16GB 32 512GB 2 & 4 Y Y 4
17 RDIMM 4GB 16 64GB 2 & 4 Y N 4
16x8GB + 16x16GB 32 384GB 2 & 4 Y Y 4
19 RDIMM 1GB 2 2GB 2 & 4 Y Y 1
Table 8. Supported Memory Configurations

The PowerEdge M910 system board incorporates the Intel® 7500 chipset for I/O and processor interfacing. The 7500 chipset is designed to support Intel® Xeon® processor 6500 and 7500 series 4S family, Intel® QPI Interconnect, DDR3 memory technology, and PCI Express Generation 2 (PCIe 2). The 7500 chipset consists of the IOH QuickPath Interconnect (QPI), Intel® 7500 Scalable Memory Buffer, and the ICH10 South Bridge.
The PowerEdge M910 system board incorporates an Intel 7500 series IOH to provide a link between the 4S processors and the I/O components. The main components of the IOH consist of two full‐width QPI links (one to each processor), 36 lanes of PCIe Gen2, and a x4 DMI link to connect directly to the ICH10 (Intel I/O Controller Hub 10) South Bridge.
The QPI architecture consists of serial point‐to‐point interconnects for the processors and the IOH. The PowerEdge M910 has a total of four QPI links including one link connecting the processors and links connecting both processors with the IOH. Each link consists of 20 lanes (full‐width) in each direction with a link speed of 6.4 GT/s. An additional lane is reserved for a forwarded clock. Data is sent over the QPI links as packets.
The QPI architecture features the following four layers:
The Physical layer consists of the actual connection between components. It supports Polarity Inversion and Lane Reversal for optimizing component placement and routing. The Link layer is responsible for flow control and the reliable transmission of data. The Routing layer is responsible for the routing of QPI data packets. Finally, the Protocol layer is responsible for high‐level protocol communications, including the implementation of a MESIF (Modify, Exclusive, Shared, Invalid, Forward) cache coherence protocol.
PCI Express (PCIe) is a serial point‐to‐point interconnect for I/O devices. PCIe Gen2 doubles the signaling bit rate of each lane from 2.5 Gb/s to 5 Gb/s. Each of the PCIe Gen2 ports is backward‐ compatible with Gen1 transfer rates.
The DMI (previously called the Enterprise Southbridge Interface) connects the Intel 7500 Legacy IOH with the Intel I/O Controller Hub (ICH). The DMI is equivalent to a x4 PCIe Gen1 link with a transfer rate of 1 GB/s in each direction.
ICH10 is a highly integrated I/O controller, supporting the following functions:

o M910 BIOS flash device is connected to the ICH10 using SPI
The M910 supports four PCI Express Gen 2 x8 mezzanine connectors. There are no restrictions on mezzanine cards in the M910 (i.e., size or location).

9.1 Overview
The PowerEdge M910 BIOS is based on the Dell BIOS core, and supports the following features:
The PowerEdge M910 supports the standard ACPI states. See http://www.acpi.info/for more information.

Two embedded Broadcom® 5709S dual-port LAN controllers are on the PowerEdge M910 system board as independent Gigabit Ethernet interface devices. The following information details the features of the LAN devices:

11.1 Overview
The M910 contains four PCIe Gen2 mezzanine slots. Installation of mezzanine cards requires an M1000e I/O Module (IOM) of the same fabric technology to be installed in the corresponding fabric slot of the mezzanine to support data flow through that fabric/slot.
For more information, refer to the PowerEdge M1000e Technical Guide.
Available options for all 4 slots include:

12.1 Drives
The PowerEdge M910 supports up to two 2.5‖ SAS hard disk drives.
The PowerEdge M910 supports the 11G 2.5‖ hard drive carrier. Legacy carriers are not supported on M910.

Figure 7. 2.5” HDD Carrier
For the slots that are not occupied by drives, a carrier blank is provided to maintain proper cooling, maintain a uniform appearance to the unit, and provide EMI shielding.
The system supports diskless configuration with no storage controller (H200/PERC 7i) installed in the system. A 2.5‖ HDD backplane is installed in this configuration.

Table 9. RAID Configurations

0 N 0 0 ZERO Diskless Configuration, No daughtercard
1 N 1 2 ASSN SAS drives using SAS6/IR or H200 daughtercard with no RAID
2 N 2 2 ASSR0 SAS drives using the SAS6/IR or H200 daughtercard with drives in a RAID 0 mirror
3 Y 2 2 ASSR1 SAS drives using the SAS6/IR or H200 daughtercard with drives in a RAID 1 Stripe
4 N 2 2 ASSCBR0 SAS or Solid State drives using the PERC6 or H700 daughtercard (w/ battery) with drives in a RAID 0 Stripe
5 Y 2 2 ASSCBR1 SAS or Solid State drives using the PERC6 or H700 daughtercard (w/ battery) with drives in a RAID 1 mirror
Table 10. Storage Controllers Supported on the M910

Yes – Max 1 Storage slot X4 No x4 integrated mini SAS wide 0, 1, 10 No
The M910 does not support the SATA repeater. The only SATA drives supported by M910 are the SSD drives which are only supported off the PERC solution.

For customers who want a hardware RAID solution, the PERC6i is available as an optional customer kit. The PERC6i uses the LSI 1078 ROC (RAID on Chip) processor with a PCI Express host interface and DDR2 memory. A battery is available with this card.
The M910 supports the PERC H200, which offers a battery-backed cache. Details of the PERC H200 can be found in the PERC H200 Technical Guidebook.
The M910 also supports the PERC H700. Details of the PERC H700 can be found in the PERC H700 Technical Guidebook. It offers a battery-backed cache.
Each disk drive carrier has two LED indicators visible from the front of the system. One is a green LED for disk activity and the other is a bicolor (Green/Amber) LED for status. Both LEDs are used to indicate certain conditions under direction of a storage controller.
Optical drives are optional in all M910 systems and connect to the blade via the front USB interface. The following internal slim-line drives are available on the M910:
PATA (IDE) optical drives are not supported.

The PowerEdge M910 Integrated Dell Remote Access Controller 6 (iDRAC6) incorporates an integrated video subsystem connected to the 32-bit PCI interface of the ICH10. This logic is based on the Matrox® G200. The device only supports 2D graphics.
The integrated video core shares its video memory with the iDRAC6’s 128 MB DDR2 application space memory. This memory is also used for the KVM buffer.
The M910 system supports the following 2D graphics video modes:
Table 11. Supported Video Modes
Resolution Refresh Rate (Hz) Color Depth (bit)
640 x 480 60, 72, 75, 85 8, 16, 32
800 x 600 56, 60, 72, 75, 85 8, 16, 32
1024 x 768 60, 72, 75, 85 8, 16, 32
1152 x 864 75 8, 16, 32
1280 x 1024 60, 75, 85 8, 16
1280 x 1024 60 32

For information on rack and cable accessories for the M910, see the PowerEdge M1000e Technical Guide and the M1000e Rack and Cable Advisor Tool.

The PowerEdge M910 is designed to meet the MSFT WinLogo 3.0 design specifications. For the most up-to-date information, see the Operating System Support Matrix for Dell PowerEdge Systems on Dell.com.

16.1 Overview
Table 12. Virtualization Software
Hypervisor Factory Install Certification
VMware® ESX/ESXi™ 3.5U5 DIB/FI/NFI Yes
VMware® ESX/ESXi™ 4.0U1 DIB/FI/NFI Yes
Windows Server® 2008 R2 with Hyper-V™ FI Yes, included in Windows Server 2008 R2 WHQL process
Citrix® XenServer™ 5.6 FI Yes
Support.dell.com has extensive information designed to help customers configure virtualization software with PowerEdge servers.
To configure a complete virtualization solution, another resource is the Dell Virtualization Solution Advisor on dell.com. Support.dell.com also has many blade-related virtualization documents, as well as a detailed list of the virtualization platforms that are supported by OpenManage.
For information about what versions of VMware software have been certified on this server, see the compatibility list maintained by VMware.
It is possible to order the server with an SD card that does not contain ESXi.
Dell Advanced Infrastructure Manager (AIM) allows IT organizations to manage networking, storage, and servers (as well as server workloads) that can be dynamically reconfigured and deployed to meet the changing needs of today’s data center environment. Specifically, AIM provides IT professionals the ability to:

The following platforms have been certified by Scalent:
Nov 2009: 2970, R610, R710, M1000E, 1955, M605, M610, M710, and M905.
April 2010: R810, R815, R910, and M910.
More information can be found at www.dell.com/aim.
Vizioncore's easy-to-use virtualization software products support business continuity and disaster recovery, high availability, monitoring, automation, P2V and optimization. The software is agent-less and can co-exist with other leading backup software vendors, or be used as a standalone solution.
vRanger™ Pro is a backup and restore solution for virtualized environments.
vFoglight™ Standard and Professional editions help organizations monitor, understand and analyze their virtual infrastructure by managing the relationships and interaction between all the components in the virtual environment.
vConverter™ helps convert servers to the VMware, Microsoft, XenServer or Virtual Iron platforms.
vReplicator is a host-level software-based replication solution for VMware infrastructure which enables companies to leverage virtualization to support High Availability (HA) and Disaster Recovery (DR) strategies.
Vizioncore™ vOptimizer Pro helps administrators understand storage utilization so they can make real-time adjustments in allocations. It presents the financial impact of reclaimed storage per virtual machine (VM), per host, and cumulative cost savings across the enterprise through historical detailed reports.
vControl is a VM management solution that provides self-service provisioning, multi-VM control and task-based automation. vControl lets VM consumers build and deploy VMs for themselves, while providing administrators a single interface for task-based administration of VMs.
Vizioncore vEssentials™ is a software bundle of vFoglight Pro, vRanger Pro and vReplicator.
More information can be found at http://vizioncore.com/asg/

17.1 Overview
Dell aims on delivering open, flexible, and integrated solutions that help you reduce the complexity of managing disparate IT assets by building comprehensive IT management solutions. Combining Dell PowerEdge Servers with a wide selection of Dell-developed management solutions gives you choice and flexibility, so you can simplify and save in environments of any size. To help you meet your server performance demands, Dell offers Dell™ OpenManage™ systems management solutions for:
A Dell Systems Management and Documentation DVD and a Dell Management Console DVD are included with the product. ISO images are also available. A brief description of available content:

The PowerEdge M910 implements circuitry for the next generation of Embedded Server Management. It is Intelligent Platform Management Interface (IPMI) v2.0 compliant. The optional iDRAC (Integrated Dell Remote Access Controller) is responsible for acting as an interface between the host system and its management software and the periphery devices.
The optional upgrade to iDRAC6 provides features for managing the server remotely or in data center lights-out environments.
Advanced iDRAC features require the installation of the optional iDRAC6 Enterprise card.
Embedded management is comprised of several interdependent pieces:
Dell Unified Server Configurator (USC) is a local 1:1 graphical user interface embedded on Lifecycle Controller that aids in local server provisioning in a pre-OS environment. For servers with iDRAC Express, the Lifecycle Controller offers OS install, platform updates, platform configuration, and diagnostics capabilities. For servers without iDRAC Express, this utility has limited functionality and offers OS install and diagnostics capabilities only.
To access the Unified Server Configurator, press the key within 10 seconds of the Dell logo’s appearance during the system boot process. Current functionality enabled by the Unified Server Configurator includes:
Table 13. Unified Server Configurator Features and Description
Faster O/S Installation Drivers and the installation utility are embedded on system, so no need to scour DELL.COM.
Faster System Updates Integration with Dell support automatically directed to latest versions of the Unified Server Configurator, iDRAC, RAID, BIOS, NIC, and Power Supply.
Update Rollback Ability to recover to previous ―known good state‖ for all updatable components.
More Comprehensive Diagnostics Diagnostic utilities are embedded on system.
Simplified Hardware Configuration Detects RAID controller and allows user to configure virtual disk and choose virtual disk as boot device, eliminating the need to launch a separate utility. Also provides configuration for iDRAC, BIOS, and NIC/LOM.
Feature Description

In addition to upgrading the system with a Lifecycle Controller, the iDRAC6 offers the following key features:
A more detailed feature list for iDRAC6 and vFlash is included in the table below.
Table 14. Features List for BMC, iDrac, and vFlash



See the PowerEdge M1000e Technical Guide.

18.1 USB peripherals
The PowerEdge M910 provides an internal USB connector for a USB flash memory key. The USB memory key can be used as a boot device, security key, or mass storage device.
By use of the appropriate IOMs in the M1000e chassis and mezzanine card(s) in the M910 blade, the following external storage options are available: Disk Storage Options:

Regulatory Certifications and Standards Compliance Appendix A.
Please see the external Product Safety, EMC, and Environmental Datasheets on dell.com at: http://www.dell.com/regulatory_compliance_datasheets
The M910 systems conform to the industry standards shown in Table 15.
Table 15. Industry Standards and URLs

SATA Serial ATA Rev. 2.6; SATA II, Extensions to SATA 1.0a, Rev. 1.2

Standard URL for information and specifications
USB Universal Serial Bus Specification, Rev. 2.0
http://www.usb.org/developers/docs/
Windows Logo Windows Logo Program System and Device Requirements, v3.10