Instruction/ maintenance manual of the product CH-461C Citizen
Go to page of 27
INSTRUCTION MANUAL FOR DIGIT AL BLOOD PRESSURE MONITOR REF CH-461C Design and Specification are subject to change without notice. CITIZEN is a register ed trademark of Citizen Holdings Co., Japan. CITIZEN es una marca r egistrada de Citizen Holdings Co.
- Eng 2 - Ensure that you have all the following components Contents 3 - GENERAL REMARKS 5 - PRECAUTIONS FOR USE AND MAINTENANCE 8 - UNIVERSAL DESIGN 9 - IDENTIFICA TIONS OF P ARTS 11 - LOADING THE BA.
- Eng 3 - English General remarks on blood pr essure and blood pr essure measurement 1. T o defl ate the cuf f quickly , press the “ST AR T/STOP” switch. 2. The attached cuff is suitable for arm cir cumferences of 20-32 cm. 3. When attaching the cuff, the air hose should be placed on the inside of your arm on top of the artery .
- Eng 4 - English GENERAL REMARKS 9. DO NOT measure blood pr essure when the cuff has been on your arm for a few minutes or more. During this time, your arm will have built up a higher blood pressur e and you will not get valid reading. 10. The fi gure below shows the blood pressur e classifi cations under the WHO standards.
- Eng 5 - English Precautions for use 1. If you suffer fr om heart disease, high blood pressure or other cir culatory disease, consult your physician before using the monitor .
- Eng 6 - English PRECAUTIONS FOR USE AND MAINTENANCE 15. Be sure to use this unit only for measuring blood pressure. DO NOT use it for any other purpose.
- Eng 7 - English Nature and fr equency of maintenance: This product is designed for use over an extended period of time; however , it is generally recommended that it be inspected every two years to ensure pr oper function and performance.
- Eng 8 - English This product has been developed with the concept of Universal Design to ensur e safe and easy use for a broader range of users. The pr oduct’ s shape and color was designed to port.
- Eng 9 - English <Main Unit> Component names IDENTIFICA TION OF P AR TS Air hose socket ST ART/STOP Switch a Stand-by Battery icon Systolic blood pressure display Diastolic blood pressure displ.
- Eng 10 - English IDENTIFICA TION OF P ARTS Air hose connector Air hose Cuff <Cuff>.
- Eng 11 - English (Batteries supplied with the unit should be loaded in compartment before putting the Blood pressur e monitor in use.) LOADING THE BA TTERIES 1 Open the cover of battery compartment. Pressing the hook down, pull the cover towar d you to open.
- Eng 12 - English LOADING THE BA TTERIES REMOVING THE BA TTERIES • When the icon is displayed, or where the clock is no longer shown or nothing appears in the display , replace the old batteries with four new ones. All four batteries should be changed at once.
- Eng 13 - English USING AC ADAPTER (OPTION) • If you plan to use the AC adapter for an extended period of time, remove the batteries. If the batteries are left in the compartment, electr olyte may leak from the batteries and cause a fault in the blood pressur e monitor .
- Eng 14 - English 3 Adjust the position of the arm cuff so that the blue marker is located in the center of your arm and the hem of the cuff is 1 to 2 cm above your elbow . MEASURING YOUR BLOOD PRESSURE * The cuff should be put on the bare arm or over a light-weight underwear .
- Eng 15 - English MEASURING YOUR BLOOD PRESSURE 4 Pull the end of the arm cuff outwards so that the cuf f is snug around your arm and then secure the end to the V elcro. 5 Place your arm on a table or the like so that the center of the cuff comes to the height of your heart.
- Eng 16 - English TIPS FOR OBT AINING ACCURA TE MEASUREMENTS Y our blood pressure varies accor ding to your posture, the time of day and a range of other factors. Ideally , you should measure your blood pressur e in the same posture at the same time every day .
- Eng 17 - English MEASURING YOUR BLOOD PRESSURE • Plug the air hose connector fi rmly into the air hose socket on the main unit as illustrated. • Press the "ST ART/STOP" switch. • All of the segment will be displayed • The mark comes on.
- Eng 18 - English MEASURING YOUR BLOOD PRESSURE • Wait a while after the completion of pr essurization. Then, the mark comes on and the unit automatically starts measuring your blood pressures. • When the unit detects your pulse, the mark fl ashes on and off, then the unit gives your blood pressur e value on the lower section of the display .
- Eng 19 - English [Manual pressurization] • Keep “ST ART/STOP” switch held pressed until the pressure value you want to stop pr essurization is reached (approximately 40mmHg higher than the Systolic blood pressure). Y ou can stop pressurization by the unit by releasing the switch at the aforementioned value is reached.
- Eng 20 - English HOW TO CALL UP THE V ALUES STORED IN MEMOR Y TO THE DISPLA Y • Except for the case where the unit is engaged in measurement, pr ess “MEMORY” switch to call up the values (measurement r esults) stored in memory to the display .
- Eng 21 - English HOW TO CALL UP THE DA T A STORED IN MEMOR Y • Press the “MEMORY” switch again. This r ecalls and displays fi rst the memory number and then the last set of data stored. • Press the “MEMORY” switch again. This r ecalls and displays the second last set of data stored.
- Eng 22 - English Icon displayed Condition/Cause Corrective action Insuffi cient pr essure. Repeat measurement again. Appears when the blood- pressur e could not be measured accurately . Reapply cuff pr operly and measure again. The pressur e is 281 mmHg or higher .
- Eng 23 - English ABOUT “BLOOD PRESSURE” What is blood pressur e? The heart is a pump that circulates blood thr oughout your body . Blood is pumped from the heart at a constant pr essure into arteries. This pressur e is called the arterial blood pressur e and represents, in general terms, your blood pr essure.
- Eng 24 - English Q Why is the blood pressure measur ed at home differ ent from that measured by the physician or at a hospital? A Y our blood pressure may vary due to exercise, the ambient temperatur e or your mental state.
- Eng 25 - English Make sure to check the following befor e sending your blood pressure monitor away to be tested or repair ed. Problem Checks Response Display stays blank when you press the “ST ART/ STOP” switch. Check whether the batteries are dead.
- Eng 26 - English SPECIFICA TIONS Model Number: CH-461C Measurement system: Oscillometric method Measurement Localization Upper Arm Cuff: Soft cuff Arm circumference range: 20.
INSTRUCTION MANUAL FOR DIGIT AL BLOOD PRESSURE MONITOR REF CH-461C Design and Specification are subject to change without notice. CITIZEN is a register ed trademark of Citizen Holdings Co., Japan. CITIZEN es una marca r egistrada de Citizen Holdings Co.
An important point after buying a device Citizen CH-461C (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Citizen CH-461C yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Citizen CH-461C - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Citizen CH-461C you will learn all the available features of the product, as well as information on its operation. The information that you get Citizen CH-461C will certainly help you make a decision on the purchase.
If you already are a holder of Citizen CH-461C, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Citizen CH-461C.
However, one of the most important roles played by the user manual is to help in solving problems with Citizen CH-461C. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Citizen CH-461C along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center