Security Manager 2000p.1User's Manualp.1Security Systemp.1PROPER INTRUSION PROTECTIONp.2About This Manualp.2IMPORTANT!p.2DISARMING AND SILENCING ALARMS ..................... 17p.3ARMING ALL PROTECTION (AWAY) ......................... 16p.3ARMING PERIMETER ONLY (INSTANT) .................... 15p.3ARMING PERIMETER ONLY (STAY) ......................... 14p.3CHECKING FOR OPEN ZONES ................................. 13p.3TABLE OF CONTENTSp.3LIMITATIONS OF THE ALARM SYSTEM .................... 40p.3QUICK GUIDE TO SYSTEM FUNCTIONS ................... 34p.3MAINTAINING YOUR SYSTEM .................................. 32p.3TROUBLE CONDITIONS ........................................... 29p.3PAGING FEATURE .................................................... 24p.3USING DEVICE COMMANDS ..................................... 23p.3SYSTEM OVERVIEWp.4SYSTEM OVERVIEW (Continued)p.6ENTRY/EXIT DELAYSp.7ENTRY/EXIT DELAYS (Continued)p.8ABOUT THE TOUCHPADSp.9ABOUT THE TOUCHPADS (Continued) English Display Touchpadp.10Ê ÊÊENGLISH DISPLAY TOUCHPADp.10ALARM FIREp.10AWAY BYPASS STAY CHECK INSTANTp.10NO AC TEST NOT READY CHIME BATp.10FUNCTIONS OF THE TOUCHPADSp.11DISARMED - P RESS , TO S HOW FAULTSp.13TYPICAL DISPLAYS WHEN NOT READY TO ARMp.13CHECKING FOR OPEN ZONESp.13TYPICAL DISPLAYS INDICATING "READY TO ARM"p.13ACp.13ARMING PERIMETER ONLY (With Entry Delay ON)p.14ENGLISH DISPLAY TOUCHPAD CUSTOM DISPLAY TOUCHPADp.14STAYp.14AC ARMED *** STAY *** YOU MAY EXIT NOWp.14TYPICAL DISPLAYS Ð ÒARMED STAYÓp.14Using the Ê 7 Ê INSTANT Keyp.15ARMING PERIMETER ONLY (With Entry Delay OFF)p.15ENGLISH DISPLAY TOUCHPAD C USTOM DISPLAY TOUCHPADp.15STAY INSTANTp.15TYPICAL DISPLAYS Ð ÊÒARMED INSTANTÓp.15AC ARMED * INSTANT * YOU MAY EXIT NOWp.15ARMING ALL PROTECTION (With Entry Delay ON)p.16ENGLISH DISPLAY TOUCHPADp.16Ê ÊÊÊENGLISH DISPLAY TOUCHPADp.16AWAY ACp.16DISARMING AND SILENCING ALARMSp.17CUSTOM DISPLAY TOUCHPAD ENGLISH DISPLAY TOUCHPADp.17ALARM 06 BEDROOM WINDOW 06 ALARMp.17TYPICAL BURGLARY ALARM DISPLAYp.17BYPASSING PROTECTION ZONESp.1806 BYPASSp.18BYPASS 06 BEDROOM WINDOWp.18TYPICAL MOMENTARY DISPLAYS OF BYPASSED ZONE(S)p.18ENGLISH DISPLAY TOUCHPAD ENGLISH DISPLAY TOUCHPADp.18CUSTOM DISPLAY TOUCHPADp.18DISARMED BYPASS READY TO ARMp.18BYPASSp.18BYPASSING PROTECTION ZONES (Continued)p.19Quick Bypassp.19ÊÊÊENGLISH DISPLAY TOUCHPAD ENGLISH ÊDISPLAY TOUCHPADp.19BYPASS 02 REAR DOOR CUSTOM DISPLAY TOUCHPADp.19AWAY BYPASSp.19AC BYPASSp.19ÊÊÊÊÊCUSTOM DISPLAY TOUCHPADp.19ÊÊÊÊÊÊCUSTOM DISPLAY TOUCHPADp.19ARMED *** AWAY *** ZONE BYPASSEDp.19CHIME MODEp.20FAULT 02 REAR DOOR 02p.20DISARMED CHIME READY TO ARMp.20NOT READY CHIMEp.20CHIMEp.20PANIC KEYS (FOR MANUALLY ACTIVATING SILENT AND/OR AUDIBLE ALARMS)p.21ÊCUSTOM DISPLAY TOUCHPAD ENGLISH DISPLAY TOUCHPADp.21ALARM 99 99 ALARMp.21NOT READYp.21SINGLE-BUTTON PAGING FEATUREp.22
Page 1 of the ADT Security Services Security Manager 2000 user manual — Ê
Page 1 · click to enlarge
Page 1

N7527–6V2 4/99 Ref. 20ADTEG/20ADTED UL File No. S1632

Security Manager 2000

User's Manual

Security System

ADT Security Services Security Manager 2000 — Security Manager 2000 diagram (page 1)
Fig. 1 · Security Manager 2000

Ê

Page 2 of the ADT Security Services Security Manager 2000 user manual — PROPER INTRUSION PROTECTION
Page 2 · click to enlarge
Page 2

This manual is a step-by-step guide that will acquaint you with the system's features and benefits. It defines the components and their functions, describes their operation, and provides clear step-by-step instructions for normal and emergency procedures. Keep this manual in a convenient place so that you can refer to it as necessary.

For proper intrusion coverage, sensors should be located at every possible point of entry to a home or commercial premises. This would include any skylights that may be present, and the upper windows in a multi-level building. In addition, we recommend that radio backup be used in a security system so that alarm signals can still be sent to an alarm monitoring station in the event that the telephone lines are out of order (alarm signals are normally sent over the phone lines).

PROPER INTRUSION PROTECTION

About This Manual

IMPORTANT!

Page 3 of the ADT Security Services Security Manager 2000 user manual — Table of Contents
Page 3 · Contents
Contents

Contents

Security Manager 2000p.1User's Manualp.1Security Systemp.1PROPER INTRUSION PROTECTIONp.2About This Manualp.2IMPORTANT!p.2DISARMING AND SILENCING ALARMS ..................... 17p.3ARMING ALL PROTECTION (AWAY) ......................... 16p.3ARMING PERIMETER ONLY (INSTANT) .................... 15p.3ARMING PERIMETER ONLY (STAY) ......................... 14p.3CHECKING FOR OPEN ZONES ................................. 13p.3TABLE OF CONTENTSp.3LIMITATIONS OF THE ALARM SYSTEM .................... 40p.3QUICK GUIDE TO SYSTEM FUNCTIONS ................... 34p.3MAINTAINING YOUR SYSTEM .................................. 32p.3TROUBLE CONDITIONS ........................................... 29p.3PAGING FEATURE .................................................... 24p.3USING DEVICE COMMANDS ..................................... 23p.3SYSTEM OVERVIEWp.4SYSTEM OVERVIEW (Continued)p.6ENTRY/EXIT DELAYSp.7ENTRY/EXIT DELAYS (Continued)p.8ABOUT THE TOUCHPADSp.9ABOUT THE TOUCHPADS (Continued) English Display Touchpadp.10Ê ÊÊENGLISH DISPLAY TOUCHPADp.10ALARM FIREp.10AWAY BYPASS STAY CHECK INSTANTp.10NO AC TEST NOT READY CHIME BATp.10FUNCTIONS OF THE TOUCHPADSp.11DISARMED - P RESS , TO S HOW FAULTSp.13TYPICAL DISPLAYS WHEN NOT READY TO ARMp.13CHECKING FOR OPEN ZONESp.13TYPICAL DISPLAYS INDICATING "READY TO ARM"p.13ACp.13ARMING PERIMETER ONLY (With Entry Delay ON)p.14ENGLISH DISPLAY TOUCHPAD CUSTOM DISPLAY TOUCHPADp.14STAYp.14AC ARMED *** STAY *** YOU MAY EXIT NOWp.14TYPICAL DISPLAYS Ð ÒARMED STAYÓp.14Using the Ê 7 Ê INSTANT Keyp.15ARMING PERIMETER ONLY (With Entry Delay OFF)p.15ENGLISH DISPLAY TOUCHPAD C USTOM DISPLAY TOUCHPADp.15STAY INSTANTp.15TYPICAL DISPLAYS Ð ÊÒARMED INSTANTÓp.15AC ARMED * INSTANT * YOU MAY EXIT NOWp.15ARMING ALL PROTECTION (With Entry Delay ON)p.16ENGLISH DISPLAY TOUCHPADp.16Ê ÊÊÊENGLISH DISPLAY TOUCHPADp.16AWAY ACp.16DISARMING AND SILENCING ALARMSp.17CUSTOM DISPLAY TOUCHPAD ENGLISH DISPLAY TOUCHPADp.17ALARM 06 BEDROOM WINDOW 06 ALARMp.17TYPICAL BURGLARY ALARM DISPLAYp.17BYPASSING PROTECTION ZONESp.1806 BYPASSp.18BYPASS 06 BEDROOM WINDOWp.18TYPICAL MOMENTARY DISPLAYS OF BYPASSED ZONE(S)p.18ENGLISH DISPLAY TOUCHPAD ENGLISH DISPLAY TOUCHPADp.18CUSTOM DISPLAY TOUCHPADp.18DISARMED BYPASS READY TO ARMp.18BYPASSp.18BYPASSING PROTECTION ZONES (Continued)p.19Quick Bypassp.19ÊÊÊENGLISH DISPLAY TOUCHPAD ENGLISH ÊDISPLAY TOUCHPADp.19BYPASS 02 REAR DOOR CUSTOM DISPLAY TOUCHPADp.19AWAY BYPASSp.19AC BYPASSp.19ÊÊÊÊÊCUSTOM DISPLAY TOUCHPADp.19ÊÊÊÊÊÊCUSTOM DISPLAY TOUCHPADp.19ARMED *** AWAY *** ZONE BYPASSEDp.19CHIME MODEp.20FAULT 02 REAR DOOR 02p.20DISARMED CHIME READY TO ARMp.20NOT READY CHIMEp.20CHIMEp.20PANIC KEYS (FOR MANUALLY ACTIVATING SILENT AND/OR AUDIBLE ALARMS)p.21ÊCUSTOM DISPLAY TOUCHPAD ENGLISH DISPLAY TOUCHPADp.21ALARM 99 99 ALARMp.21NOT READYp.21SINGLE-BUTTON PAGING FEATUREp.22
Page 4 of the ADT Security Services Security Manager 2000 user manual — SYSTEM OVERVIEW
Page 4 · click to enlarge
Page 4

General Congratulations on your ownership of an ADT Partitioned Security System. You've made a wise decision in choosing it, for it represents the latest in security protection technology today, and millions of premises are protected by ADT systems. This system offers you two forms of protection: burglary and emergency. Your system consists of at least one touchpad which provides control of system operation, and includes various sensors which provide perimeter and interior burglary protection. The system uses microcomputer technology to monitor all protection zones and system status, display appropriate information on the touchpad(s) used with the system, and initiate appropriate alarms. Your system may also have been programmed to automatically send alarm or status messages over the phone lines to a Customer Care Center.

Zones Your system's sensing devices have been assigned to various "zones." For example, the sensing device on your Entry/Exit door may have been assigned to zone 01, devices on windows in the master bedroom to zone 02, and so on. If an alarm or trouble condition occurs, these numbers will appear on the display, along with a description for that zone (if programmed).

Simply stated, a partitioned system is a single physical alarm system that provides independent areas of protection intended for use by independent users. For the most part, you need not know about other users and their structure in the system, but from time to time, you may see display messages which indicate the system is in use by another user; this is normal. A partitioned system may also have a "common zone" area, which is an area shared by users of both partitions. Refer to the COMMON ZONE OPERATION section for details on using this feature.

SYSTEM OVERVIEW

A Partitioned System

Page 5 of the ADT Security Services Security Manager 2000 user manual — SYSTEM OVERVIEW
Page 5 · click to enlarge
Page 5

Memory of Alarm When an alarm condition occurs, the touchpad displays the number(s) of the zone(s) that caused the problem, and displays the type of alarm. It remains displayed until it is cleared by disarming the system (see DISARMING THE SYSTEM section).

Alarms When an alarm occurs, both the touchpad and external sounders will sound, and the touchpad will display the zone(s) causing the alarm. If your system is connected to a Customer Care Center, an alarm message will also be sent. To stop the alarm sounding, simply disarm the system.

ÊArming ÊModeFeatures For Each Arming Mode Exit Delay Entry Delay Perimeter Armed Interior Armed AWAYYesYesYesYes STAYYesYesYesNo INSTANTYesNoYesNo
Page 6 of the ADT Security Services Security Manager 2000 user manual — SYSTEM OVERVIEW (Continued)
Page 6 · click to enlarge
Page 6

Single-Button Arming Feature Check with your installer if single-button arming is present in your system.

Phone Access & Voice Response Capability

Paging Feature If the paging feature has been programmed for your system, a pager will respond to certain conditions as they occur in your system. The pager will display code numbers indicating the type of condition that has occurred. Refer to the PAGING FEATURE section later in this manual for detailed information. Single-Button Paging The touchpads have a special key (identified as the ÒDÓ key) which may be used to signal a Pager. The message displayed on the Pager when this key is pressed is 999–9999. This code could mean Òcall homeÓ, Òcall your officeÓ, or whatever you decide this code will mean. See SINGLE-BUTTON PAGING FEATURE section.

SYSTEM OVERVIEW (Continued)

If programmed for your system, keys A and B on the touchpads may have been programmed for single-button arming without the use of a security code, as follows: Key A, when pressed for 2 seconds, will arm all protection (AWAY mode). Key B, when pressed for 2 seconds, will arm the perimeter (STAY mode).

Complete information regarding the use of this feature is provided in a separate manual entitled PHONE ACCESS USER'S GUIDE, which accompanies the voice module.

Your system may include a voice module that will permit you to access the system via a Touch- tone phone, either on-premises or by call-in when away. The phone access feature will enable you to do the following: ¥ Receive synthesized voice messages over the telephone regarding the status of the security system. ¥ Arm and disarm the system and perform most function commands via the telephone, with voice confirmation provided after each command entry.

Page 7 of the ADT Security Services Security Manager 2000 user manual — ENTRY/EXIT DELAYS
Page 7 · click to enlarge
Page 7

Partition 2 Exit Delay: Ê seconds Entry Delay 1: Ê seconds

Partition 1 Exit Delay: Ê seconds Entry Delay 1: Ê seconds

See your installer for your delay times.

You can also arm the system with no entry delay at all by using the INSTANT arming mode. This mode provides greater security while on the premises or while away for extended periods of time.

Entry Delays give you time to disarm the system when you re-enter through the designated entrance door. But you must disarm the system before the entry delay period ends, or an alarm will occur. The touchpad beeps during the entry delay period, reminding you to disarm the system. There are two entry delays (if programmed). The first is for your primary entrance and the second can be used for a secondary entrance, where a longer delay is required to walk to the touchpad to disarm the system.

Your system has preset time delays, known as exit delay and entry delay. Whenever you arm your system, exit delay gives you time to leave through the designated exit door without setting off an alarm. Exit delay begins immediately after entering any arming command, and applies to all modes of arming protection. If programmed, a slow beeping will sound throughout the exit delay period.

ENTRY/EXIT DELAYS

Entry Delay 2Ê Ê Ê Ê Ê seconds
Entry Delay 2Ê Ê Ê Ê Ê seconds

General Information

Page 8 of the ADT Security Services Security Manager 2000 user manual — ENTRY/EXIT DELAYS (Continued)
Page 8 · click to enlarge
Page 8

installer if a common zone was assigned.

To minimize false alarms sent to the Customer Care Center, your system may have been programmed for this fea- ture. Ask your installer if "Exit Alarm" is active for your system.

Ê Ê Ê Ask your

Ê Ê Ê Exit Alarm Active

ENTRY/EXIT DELAYS (Continued)

Your system may have been set up to use a common zone, which is an area shared by users of both partitions, such as a foyer or lobby. If so, please note the following: ¥ The common zone will sound and report alarms only when both partitions are armed. If only one partition is armed, the system ignores faults on the common zone. ¥ Either partition may arm its system if the common zone is faulted, but once armed, the other partition will not be able to arm unless the common zone is first bypassed or the fault corrected. ¥ If either partition is armed and the other is in chime mode, the common zone will not chime. The common zone will chime if both partitions are disarmed and either is in chime mode. ¥ Faults on the common zone are displayed on touchpads in both partitions. ¥ Either partition can clear and restore the common zone after an alarm.

Whenever you arm the system, the exit delay begins. If an entry/exit door or interior zone is faulted when the exit delay ends (e.g., exit door left open), the system sounds an alarm and starts the entry delay timer. If you disarm the system before the entry delay ends, the alarm sound stops and the message "CANCELED ALARM" or "CA" is displayed on the touchpad, along with a zone number indicating the faulted zone. No message is sent to the Customer Care Center. To clear the exit alarm condition, the open zone must be made intact; to clear the display, enter your code plus OFF. If you do not disarm the system before the entry delay ends, and an entry/exit door or interior zone is still open, the alarm sound continues and an "exit alarm" message is sent to the Customer Care Center. The message ""EXIT ALARM" or "EA" is displayed on the touchpad, along with a zone number indicating the faulted zone. To stop the alarm, the system must be disarmed (your code plus OFF); to clear the display, enter your code plus OFF a second time. An Òexit alarmÓ also results if an entry/exit door or interior zone is faulted within two minutes after the end of the exit delay. COMMON ZONE OPERATION

Exit Alarms

Page 9 of the ADT Security Services Security Manager 2000 user manual — ABOUT THE TOUCHPADS
Page 9 · click to enlarge
Page 9

2-Line Custom English Display Touchpads

General Your touchpads allow you to control all system functions. The touchpads feature a telephone style (digital) touchpad and a Liquid Crystal Display (LCD) which shows the nature and location of all occurrences.

English Display touchpads are functionally identical to Custom English Display touchpads, but the LCD display uses pre-designated words to identify the nature and location of occurrences. To access the keys on the touchpad, simply open the swing-down door.

2-line Custom English Display touchpads feature a 2-line, 32-character alphanumeric LCD which can display system messages in friendly English. These touchpads can also be programmed with custom zone descriptors. To access the keys on the touchpad, simply open the swing-down door.

There are two basic types of touchpads Ð an English display touchpad and an Custom English display touchpad (both described below). English display and Custom English display touchpads are functionally the same, even though they have different types of displays. Both types of touchpads are shown on page 12.

The touchpads also feature a built-in sounder which will sound during alarms and troubles. The touchpads also "beep" during certain system functions, such as during entry/exit delay times, in CHIME mode, and when depressing any of the keys (to acknowledge the key press).

ABOUT THE TOUCHPADS

English Display Touchpads

Page 10 of the ADT Security Services Security Manager 2000 user manual — Ê ÊÊENGLISH DISPLAY TOUCHPAD
Page 10 · click to enlarge
Page 10

NOT READY: Appears when burglary portion of the system is not ready for arming (due to open protection zones). The system is ready to arm when this message disappears and the READY light comes on.

INSTANT: Perimeter burglary zones armed and entry delay is turned off.

BYPASS: This appears when one or more burglary protection zones have been bypassed.

CHECK: Appears when a malfunction is discovered in the system at any time or if an open is detected in a FIRE zone at any time or a fault in a DAY/NIGHT burglary zone during a disarmed period. Accompanied by a display of zone number in trouble.

ALARM: Appears when an intrusion has been detected and the system is armed (also appears during a fire alarm or audible emergency alarm). Accompanied by the protection zone in alarm.

CHIME: Appears when the CHIME feature is activated.

NO AC: Appears when AC power has been cut off. System is operating on backup battery power.

STAY: Perimeter burglary zones, such as protected windows and doors, are armed.

AWAY: All burglary zones, interior and perimeter, are armed.

FIRE: Appears when a fire alarm is manually initiated via a panic key(see PANIC KEYS section. Accompanied by a display of zone 95.

BAT: Low battery condition in a wireless sensor (if zone number displayed) or low system battery (if no zone number displayed).

AC: Appears when AC power is present.

ABOUT THE TOUCHPADS (Continued) English Display Touchpad

Ê ÊÊENGLISH DISPLAY TOUCHPAD

ALARM FIRE

AWAY BYPASS STAY CHECK INSTANT

NO AC TEST NOT READY CHIME BAT

Page 11 of the ADT Security Services Security Manager 2000 user manual — FUNCTIONS OF THE TOUCHPADS
Page 11 · click to enlarge
Page 11
9. Ê ÊÊ 8 ÊÊÊ Ê CODE KEY: Used to assign additional user codes Ê for other users of the system.
8. ÊÊÊ7ÊÊÊÊ INSTANT KEY: Arms in manner similar to STAY Ê mode, but without the entry delay feature. Entering via Ê the entry/exit door will cause an instant alarm.
7. ÊÊÊ6ÊÊÊÊ BYPASS KEY: Removes individual protection zones Ê from being monitored by the system.
6. ÊÊÊ5ÊÊÊÊ TEST KEY: Tests the system and alarm sounder if
4. ÊÊÊ3ÊÊÊÊ STAY KEY: Arms perimeter portion of burglary Ê system only. Interior protection is not armed, allowing Ê movement within premises without causing alarm. 5. ÊÊÊ4ÊÊÊÊ This is not a Function key. Used only as a numeric key.

ÊÊclears visual display after problem's correction. 3. ÊÊÊÊ2ÊÊÊ AWAY KEY: Arms the entire burglary system, perimeter and interior.

2. ÊÊÊ1ÊÊÊÊ OFF KEY: Disarms burglary portion of the system,
1. DISPLAY WINDOW. Custom English Display Touchpads: These 2-line, 32character Liquid Crystal Display (LCD) touchpads display protection point identification, system status, and messages. English Display Touchpads: Display protection zone ID and system status messages using pre-designated words.

ÊÊtest procedures.

ÊÊdisarmed. Refer to TESTING THE SYSTEM section for

ÊÊsilences alarms and audible trouble indicators, and

FUNCTIONS OF THE TOUCHPADS

Ê Ê 1 2 . Ê ÊÊÊ#ÊÊÊÊ KEY: This key can be used for "Quick Arming" of the

Ê 1 1 . Ê ÊÊ, Ê READY KEY: Used to display all open protection

Ê 1 0 . Ê ÊÊÊ9ÊÊÊÊ CHIME KEY: Turns CHIME mode on and off. When

14. READY INDICATOR: (GREEN) Lit when the system is ready to be armed (no faults present). While the system is disarmed, this indicator will go on and off as protection zones are closed and opened. 15. ARMED INDICATOR: (RED) Lit when the system has been armed. 16. INTERNAL SOUNDER: The built-in sounder mimics the alarm sounder during alarms, and will also "beep" during certain system functions. 17. EMERGENCY (PANIC) KEYS: Keys A, B, and C may all have been programmed for emergency functions; however, keys A and B may have been programmed for single button arming instead. For details, see PANIC KEYS section. 18. KEY D: This key may have been programmed for single- button paging (for details, see the SINGLE-BUTTON PAGING FEATURE section).

13. KEYS 0Ð9 : Used to enter your security code(s).

Êzones.

ÊÊis disarmed will sound 3 beeps at the touchpad(s).

ÊÊon, the opening of windows or doors while the system

Êsystem without use of a security code (if programmed).

Page 12 of the ADT Security Services Security Manager 2000 user manual — FUNCTIONS OF THE TOUCHPADS
Page 12 · click to enlarge
Page 12

ÊIMPORTANT! ¥ When entering codes and commands, sequential key depressions must be made within 10 seconds of one another. If 10 seconds elapse without a key depression, the entry will be aborted and must be repeated from its beginning. Be sure to observe this precaution when performing any of the procedures in this manual. ¥ If you make a mistake while entering a security code, stop, press the [,] key, and then start over. If you stop in the middle while entering a code, and then immediately start the entry over, an erroneous code might be entered.

ADT Security Services Security Manager 2000 — FUNCTIONS OF THE TOUCHPADS diagram (page 12)
Fig. 2

(Touchpads shown without swing-down front door)

Custom English Display Touchpad

ADT Security Services Security Manager 2000 — FUNCTIONS OF THE TOUCHPADS diagram (page 12)
Fig. 3

English Display Touchpad

Page 13 of the ADT Security Services Security Manager 2000 user manual — TYPICAL DISPLAYS INDICATING "READY TO ARM"
Page 13 · click to enlarge
Page 13
ADT Security Services Security Manager 2000 — DISARMED - P RESS , TO S HOW FAULTS diagram (page 13)
Fig. 4
ADT Security Services Security Manager 2000 — DISARMED - P RESS , TO S HOW FAULTS diagram (page 13)
Fig. 5

ÊÊÊENGLISH DISPLAY TOUCHPAD ENGLISH DISPLAY TOUCHPAD ENGLISH DISPLAY TOUCHPAD ÒNOT READYÓ DISAPPEARS AND THE ÒREADYÓ INDICATOR LIGHT COMES ON

DISARMED - P RESS , TO S HOW FAULTS

TYPICAL DISPLAYS WHEN NOT READY TO ARM

CHECKING FOR OPEN ZONES

Before arming your system, all protected doors, windows and other protection zones must be closed or bypassed (see BYPASSING PROTECTION ZONES section), otherwise the touchpad will display a "Not Ready" message, and the READY indicator light on your touchpad will not be lit. The READY key can be used to display all faulted zones, making it easier for you to secure any open zone. To display faulted zones, simply press and release the READY [,] key (do not enter code first). Secure or bypass the zones displayed before arming the system. The the touchpadÕs READY indicator light will come on when all protection zones have been either closed or bypassed. The system can then be armed if desired. READY TO DISPLAY OPEN ZONES, PRESS THE Ê Ê, Ê KEY.

TYPICAL DISPLAYS INDICATING OPEN PROTECTION ZONE (AFTER PRESSING READY KEY)

TYPICAL DISPLAYS INDICATING "READY TO ARM"

AC

Page 14 of the ADT Security Services Security Manager 2000 user manual — STAY
Page 14 · click to enlarge
Page 14

Ask your installer if this feature is programmed in your system. If so, place a check in this box. ÊÊÊÊ

ÊTHE STAY MODE ARMS ÊTHE PERIMETER, BUT ÊALLOWS USE OF THE ÊENTRY/EXIT DOOR. ÊPERSONS WITHIN THE ÊPREMISES CAN MOVE ÊABOUT FREELY.

BEFORE ARMING, close all doors and windows (see CHECKING FOR OPEN ZONES on page 13).

ARMING PERIMETER ONLY (With Entry Delay ON)

Using the Ê Ê3 Ê STAY Key

ENGLISH DISPLAY TOUCHPAD CUSTOM DISPLAY TOUCHPAD

Use this key when staying inside, but expect someone to use an entry/exit door later. It is also useful if you are leaving but someone is staying inside (or if you have pets which are moving throughout the premises. 1. Enter your security code and press the STAY [3] key. In some systems, pressing the ÒBÓ key on on the touchpad for 2 seconds will arm the system STAY (no code is required). The ÒBÓ key may or may not have been programmed for this. Check with your installer. 2. The touchpad beeps three times and displays the armed STAY message (see displays below). The red ARMED indicator also lights. Note that there is an exit delay in effect before arming actually takes place. See the note below. 3. After arming, an alarm sounds immediately if a protected perimeter window or non- entry/exit door is opened, but you may otherwise move freely within the premises. Anyone entering later can enter through an entry/exit door without causing an alarm, but they must disarm the system within the entry delay period to avoid sounding an alarm. Exit Delay Restart. If you wish to open the entry/exit door to let someone in after arming STAY, you can re-start the exit delay at any time Ð simply press the [,] key, then let that person in. This avoids having to disarm the system and then re-arm it again. Note: When you first arm in the STAY mode, ÒYou may exit now” will be displayed on a Custom Display Touchpad during the programmed exit delay. This delay is in effect even when arming STAY. When ÒYou may exit nowÓ disappears, the system is fully armed.

STAY

AC ARMED *** STAY *** YOU MAY EXIT NOW

TYPICAL DISPLAYS Ð ÒARMED STAYÓ

Page 15 of the ADT Security Services Security Manager 2000 user manual — STAY INSTANT
Page 15 · click to enlarge
Page 15

Ask your installer if this feature is programmed in your system. If so, place a check in this box. ÊÊÊÊ

THE INSTANT MODE ARMS THE PERIMETER (INCLUDING ENTRY/EXIT DOOR), WITH NO ENTRY DELAY. PERSONS WITHIN THE PREMISES CAN MOVE ABOUT FREELY

BEFORE ARMING, close all doors and windows (see CHECKING FOR OPEN ZONES on page 13)

Using the Ê 7 Ê INSTANT Key

ARMING PERIMETER ONLY (With Entry Delay OFF)

ENGLISH DISPLAY TOUCHPAD C USTOM DISPLAY TOUCHPAD

Use this key when staying inside and do not expect anyone to use an entry/exit door. CAUTION: Arming the system in this mode will greatly increase the chance of false alarms. Use extreme care in selecting this mode of arming. 1. Enter your security code and press the INSTANT [7] key. 2. The touchpad beeps three times and displays the armed message. The red ARMED indicator lights. Note that there is an exit delay in effect before arming actually takes place. See the note below. 3. After arming, an alarm sounds immediately if any protected perimeter door or window is opened, but you may otherwise move freely throughout the premises. An alarm sounds immediately if anyone opens an entry/exit door. Exit Delay Restart. If you wish to open the entry/exit door to let someone in after Êarming INSTANT, you can re-start the exit delay at any time Ð simply press the [,] Êkey, then let that person in. This avoids having to disarm the system and then re-arm it Êagain. Note: When you first arm the system in the INSTANT mode, ÒYou may exit nowÓ will be displayed on the second line of a Custom Display touchpad during the programmed exit delay. This delay is in effect in the system even when arming INSTANT. When the exit delay period ends, ÒYou may exit nowÓ disappears and the system is fully armed in the INSTANT mode.

STAY INSTANT

TYPICAL DISPLAYS Ð ÊÒARMED INSTANTÓ

AC ARMED * INSTANT * YOU MAY EXIT NOW

Page 16 of the ADT Security Services Security Manager 2000 user manual — Ê ÊÊÊENGLISH DISPLAY TOUCHPAD
Page 16 · click to enlarge
Page 16
ADT Security Services Security Manager 2000 — ARMING ALL PROTECTION (With Entry Delay ON) diagram (page 16)
Fig. 6 · ARMING ALL PROTECTION (With Entry Delay ON)

THE AWAY KEY ARMS THE ENTIRE SYSTEM (INTERIOR AND PERIMETER), BUT ALLOWS USE OF THE ENTRY/EXIT DOOR.

BEFORE ARMING, close all doors and windows (see CHECKING FOR OPEN ZONES on page 13)

ARMING ALL PROTECTION (With Entry Delay ON)

Using the Ê Ê2 Ê ÊAWAY Key

Use this key when no one will be staying inside. 1. Enter your security code and press the AWAY [2] key. In some systems, pressing the ÒAÓ key on the touchpad for 2 seconds will arm the system AWAY (no code is required). The ÒAÓ key may or may not have been programmed for this. Check with your installer. 2. The touchpad begins beeping and displays the armed AWAY message. The red ARMED indicator also lights. 3. You must leave through an entry/exit door during the exit delay period to avoid causing an alarm. The touchpad will beep rapidly during the last 5 seconds of the exit delay to warn you that the delay is ending. After the exit delay expires, the system arms and will sound an alarm if a protected window or non-entry/exit door is opened, or if any movement is detected inside your premises. You may re-enter through an entry/exit door, but must disarm the system within the entry delay period to avoid an alarm.

ENGLISH DISPLAY TOUCHPAD

TYPICAL DISPLAYS DURING EXIT DELAY m ARMED *** AWAY *** YOU MAY EXIT NOW

TYPICAL DISPLAYS AFTER EXIT DELAY (SYSTEM FULLY ARMED IN AWAY MODE) m ARMED *** AWAY *** **ALL SECURE ** CUSTOM DISPLAY TOUCHPAD

Ê ÊÊÊENGLISH DISPLAY TOUCHPAD

AWAY AC

Page 17 of the ADT Security Services Security Manager 2000 user manual — CUSTOM DISPLAY TOUCHPAD ENGLISH DISPLAY TOUCHPAD
Page 17 · click to enlarge
Page 17

IMPORTANT: If you return and the main burglary sounder is on, DO NOT ENTER, but CONTACT THE POLICE from a nearby safe location. If you return after an alarm has occurred and the main sounder has shut itself off, the touchpad will beep rapidly upon your entering, indicating that an alarm has occurred during your absence. LEAVE IMMEDIATELY, and CONTACT THE POLICE from a nearby safe location.

Using the Ê Ê1 Ê ÊOFF Key

DISARMING AND SILENCING ALARMS

To Silence a Manually Initiated Fire Alarm* Simply press the OFF key to silence the alarm. Then enter the security code plus OFF sequence to clear the touchpad's Memory of Alarm display.

To Silence a Burglary Alarm SEE IMPORTANT NOTE AT LEFT! A BURGLARY alarm is a continuous/steady sound. Enter your security code and press the OFF key to silence the alarm (or warning tones of a Memory of Alarm). Note the zone in alarm on the touchpad display, and make that zone intact (close door, window, etc.). Now enter the security code plus OFF sequence again to clear the touchpad's Memory of Alarm display.

To Disarm the System Enter your security code and press the OFF key. The "Ready" indicator light will be lit if all zones are secure, and the touchpad will emit a single tone to confirm that the system is disarmed.

The OFF key is used to disarm the system, silence alarm and trouble sounds, and clear alarm memories. A BURGLARY alarm is a continuous/steady sound from the touchpads and any external sounders.

CUSTOM DISPLAY TOUCHPAD ENGLISH DISPLAY TOUCHPAD

ALARM 06 BEDROOM WINDOW 06 ALARM

TYPICAL BURGLARY ALARM DISPLAY

AC

Page 18 of the ADT Security Services Security Manager 2000 user manual — CUSTOM DISPLAY TOUCHPAD
Page 18 · click to enlarge
Page 18

To display bypassed zones prior to arming (see displays above, right), enter your security code and press the BYPASS [6] key. This will also bypass any open zones at that time (if ÒQuick BypassÓ is enabled Ð see following page).

TO BYPASS ZONES: ¥ Enter code. ¥ Press BYPASS key. ¥ Enter zone Nos. ¥ Wait for bypassed zones ÊÊto be displayed. ¥ Arm system as usual.

All bypasses are removed when an OFF sequence (security code plus OFF) is performed.

Using the Ê Ê6 Ê BYPASS Key

BYPASSING PROTECTION ZONES

This key is used when you want to arm your system with one or more zones intentionally unprotected. The system must be disarmed first. 1. Enter your security code and press the BYPASS [6] key. 2. Enter the zone number(s) for the zone(s) to be bypassed (e.g., 06, 10, 13, etc.). Single digit zone numbers must be preceded by a zero (e.g. 05, 06). 3. When finished, the touchpad will momentarily display a "Bypass" message for each bypassed zone number. Wait for these zones to be displayed, to confirm their bypass. 4. Arm the system as usual. Bypassed zones are unprotected and will not cause an alarm if violated while your system is armed.

06 BYPASS

BYPASS 06 BEDROOM WINDOW

TYPICAL MOMENTARY DISPLAYS OF BYPASSED ZONE(S)

ENGLISH DISPLAY TOUCHPAD ENGLISH DISPLAY TOUCHPAD

CUSTOM DISPLAY TOUCHPAD

AC THE ÒREADYÓ INDICATOR WILL LIGHT TO SIGNIFY THAT THE SYSTEM IS READY TO ARM

TYPICAL DISPLAYS AFTER ALL BYPASSED ZONES HAVE BEEN DISPLAYED (PRIOR TO ARMING)

DISARMED BYPASS READY TO ARM

CUSTOM DISPLAY TOUCHPAD

BYPASS

AC

Page 19 of the ADT Security Services Security Manager 2000 user manual — AWAY BYPASS
Page 19 · click to enlarge
Page 19

Ask your installer if "Quick Bypass" is active for your system, and if so, check here: ÊÊÊ

BYPASSING PROTECTION ZONES (Continued)

Quick Bypass

TYPICAL DISPLAYSAFTER THE SYSTEM IS ARMED WITH BYPASSED ZONES

ÊÊÊENGLISH DISPLAY TOUCHPAD ENGLISH ÊDISPLAY TOUCHPAD

If your system supports "Quick Bypass", it allows you to easily bypass all open (faulted) zones without having to enter zone numbers individually. This feature is useful if, for example, you routinely leave certain windows open when arming at night. To use this feature, enter your security code and, within 10 seconds, press the BYPASS [6] key, then stop. In a few moments, all open zones will be displayed along with a "Bypass" message. Wait for all bypassed zones to be displayed, then arm the system.* *Make sure that only those zones that you wish to leave unprotected are bypassed, and that there ÊÊare no other zones unintentionally left open. This feature will automatically bypass all open zones.

ENGLISH DISPLAY TOUCHPAD

BYPASS 02 REAR DOOR CUSTOM DISPLAY TOUCHPAD

TYPICAL MOMENTARY DISPLAYS TYPICAL DISPLAYS AFTER ALL BYPASSED ZONES OF BYPASSED ZONE(S) HAVE BEEN DISPLAYED (PRIOR TO ARMING) 02 BYPASS

AWAY BYPASS

AC

AC BYPASS

ÊÊÊÊÊCUSTOM DISPLAY TOUCHPAD

ÊÊÊÊÊÊCUSTOM DISPLAY TOUCHPAD

ARMED *** AWAY *** ZONE BYPASSED

DISARMED BYPASS READY TO ARM

AC

Page 20 of the ADT Security Services Security Manager 2000 user manual — CUSTOM DISPLAY TOUCHPAD ENGLISH DISPLAY TOUCHPAD
Page 20 · click to enlarge
Page 20
ADT Security Services Security Manager 2000 — CHIME MODE diagram (page 20)
Fig. 7

This feature can be used only while the burglary system is disarmed.

Using the Ê Ê9 Ê ÊCHIME Key

To turn Chime Mode off: Enter the security code and press the CHIME [9] key again. The CHIME message will disappear. TYPICAL DISPLAY WHEN CHIME IS ON

Your system can be set to alert you to the opening of a perimeter door or window while it is disarmed by using CHIME mode. When activated, three tones will sound at the Touchpad whenever a perimeter door or window is opened. Interior zones will not produce a tone when they are activated. Pressing the READY key will display the open protection points. To turn Chime Mode on: Enter the security code and press the CHIME [9] key. The CHIME message will appear.

IN CHIME MODE, ANY OPEN PROTECTION POINTS WILL BE DISPLAYED WHEN THE ÒREADYÓ KEY IS PRESSED

CHIME MODE

CUSTOM DISPLAY TOUCHPAD ENGLISH DISPLAY TOUCHPAD

CUSTOM DISPLAY TOUCHPAD ENGLISH DISPLAY TOUCHPAD

FAULT 02 REAR DOOR 02

DISARMED CHIME READY TO ARM

NOT READY CHIME

CHIME

AC

AC

Page 21 of the ADT Security Services Security Manager 2000 user manual — NOT READY
Page 21 · click to enlarge
Page 21

To Initiate a Panic Function at Any Time

*If the sytem is connected to the Customer Care Center.

PANIC KEYS (FOR MANUALLY ACTIVATING SILENT AND/OR AUDIBLE ALARMS)

ÊCUSTOM DISPLAY TOUCHPAD ENGLISH DISPLAY TOUCHPAD

Press any individual lettered key (A, B, or C) that has been programmed for the desired emergency function for at least 2 seconds. See the chart on the next page for functions that have been programmed for the various keys in your system.

ALARM 99 99 ALARM

TYPICAL DISPLAYS WHEN A PANIC KEY OR KEY PAIR THAT HAS BEEN PROGRAMMED FOR ÒAUDIBLE EMERGENCYÓ IS PRESSED.

Your system may have been programmed to use special keys to manually activate emergency (panic) functions. The emergency functions that can be programmed are: Silent Emergency, Audible Emergency, Personal Emergency, and Fire. Activating a silent emergency sends a silent alarm signal to the Customer Care Center,* but there will be no audible alarm or any visual display indicating that a silent alarm has been initiated. Activating an audible emergency sends a signal to the Customer Care Center* and sounds a loud, steady alarm at your touchpad(s) and at any external sounders that may be connected (ALARM plus a zone number is also displayed). Activating a personal emergency alarm sends an emergency message to the Customer Care Center* and sounds at touchpad(s), but not at external bells or sirens. Activating a Fire Alarm will send a fire alarm message to the Customer Care Center* and will uniquely sound external bells and sirens.

NOT READY

AC

Using Panic Keys

Page 22 of the ADT Security Services Security Manager 2000 user manual — KEY ASSIGNED FOR FIRE
Page 22 · click to enlarge
Page 22

Manually Initiating a Fire Alarm Should you become aware of a fire emergency, go to your nearest Touchpad and manually initiate a fire alarm by pressing the ÒAÓ key. Check below, and in the chart above. The ÒAÓ key is normally assigned for manually initiating a FIRE alarm. Verify this with your installer.

The ÒDÓ key on the touchpads can be used to send a signal to a Pager (check if this feature has been programmed in your system). The message displayed on the Pager when the ÒDÓ key is pressed is 999–9999. This code could mean Òcall homeÓ, Òcall your officeÓ, or other message. A pre-arranged meaning for this signal should be agreed upon. See the illustration on page 12 for the location of the ÒDÓ key. To send a signal to the Pager, simply press the ÒDÓ key for at least 2 seconds. The recipient, on seeing the 999–9999 display, will understand the pre-arranged meaning of this signal.

See your installer and note here any functions programmed for your system.

CHECK IF PANIC ZONE ACTIVE KEY(S) PLACE A CHECK NEXT TO PROGRAMMED FUNCTION DISPLAY

ÊÊÊÊ ÊÊÊÊ [C] ___SILENT,ÊÊ Ê___AUDIBLE,Ê ___PERSONAL Ê ___FIRE. 96

ÊÊÊÊ ÊÊÊÊ[B] ___SILENT,ÊÊÊ___AUDIBLE,ÊÊ___PERSONAL,Ê ___FIRE,ÊÊ ___ARM STAY* 9 9 †

ÊÊÊÊ ÊÊÊÊ[A] ___SILENT,Ê Ê___AUDIBLE,Ê Ê___PERSONAL, ___FIRE,ÊÊÊ___ARM AWAY* 9 5 †

SINGLE-BUTTON PAGING FEATURE

PANIC KEYS (Continued)

Press A for 2 seconds.

KEY ASSIGNED FOR FIRE

Page 23 of the ADT Security Services Security Manager 2000 user manual — USING DEVICE COMMANDS
Page 23 · click to enlarge
Page 23

Device Description Device Description

Example: Ê7Ê Ê2Ê Ê9Ê Ê6Ê then press #, then 8, then enter the number representing the device you wish to deactivate. See your installer for device numbers assigned for your system.

Ê + Ê Ê # Ê Ê + 8 + Ê Ê ÊÊ(Security Code) (Device Number)

ENTER SECURITY CODE THEN PRESS # + 8 + DEVICE NUMBER

Example: Ê7Ê Ê2Ê Ê9Ê Ê6Ê then press #, then press 7, then enter the number representing the device you wish to activate. See your installer for device numbers assigned for your system.

Ê + Ê Ê # Ê Ê + 7 + Ê Ê ÊÊ(Security Code) (Device Number)

ENTER SECURITY CODE THEN PRESS # + 7 + DEVICE NUMBER

Your system may be set up so that certain lights or other devices can be turned on or off by using the device command from the touchpad. Ask your installer if this has been done in your system. If programmed for your system, some devices may activate automatically upon certain system conditions. In this case, the following commands can be used to override the device activation. See your installer for a full explanation of this feature.

USING DEVICE COMMANDS

To deactivate devices · General Information · To activate devices

Page 24 of the ADT Security Services Security Manager 2000 user manual — PAGING FEATURE
Page 24 · click to enlarge
Page 24

Single-button paging, using the ÒDÓ key on an Custom Display touchpad, is also possible (see SINGLE-BUTTON PAGING FEATURE on a previous page).

Example 2. Ê Pager displays: Ê1 02Ð0005 = System is reporting a closingÐsystem arming (102) by user 5 (0005).

Example 1.ÊÊPager displays:Ê Ê9 11Ð0004 =System is reporting an alarm (911) caused by a fault on zone 4 (0004).

Examples of typical pager displays follow. Not included in the examples below are the optional 16 digits (preceding the 7-digit status code) that may have been programmed by the installer for additional data.

A = Optional 16-digits for Account numbers, PIN numbers, or any other data. This information must be programmed by the installer. B = A 3-digit code that describes the event that has occurred in your system (see explanation for event codes on the right). C = A 4-digit User or Zone number, depending on the type of event that has occurred. For alarms and troubles, these digits represent the zone number. For openings (disarming) and closings (arming), these digits represent the user number. In this system, the first 2 digits will always be Ò00Ó (e.g., 0004 will be displayed for zone number 4). Note that single-digit user or zone numbers are always preceded by a zero.

If the paging feature has been programmed, a pager will respond to certain conditions as they occur in your system by displaying a 7-digit system status code that will indicate the type of condition that has occurred. In some cases, the 7- digit code may be preceded by 16 digits, which can consist of a PIN number, Subscriber account number, or any additional data that you may wish to have sent to the pager in addition to the 7-digit system status code. The entire pager display format is as follows: 3-digit Event Code m Optional 16 digits kÊAAAAAAAAAAAAAAAA Ð BBB Ð CCCC oÊ4-digit User or Zone No.

PAGING FEATURE

911 = Alarms. The 4-digit number (CCCC) following this code will be the zone number that has caused the alarm. 811 = Troubles. The 4-digit number (CCCC) following this code will be the zone number that has caused the trouble. 101 = Open (system disarmed). The 4-digit number (CCCC) that follows this code will be the user number. 102 = Close (system armed). The 4-digit number (CCCC) that follows this code will be the user number.

The 3-digit Event Codes (BBB) that can be displayed are:

Page 25 of the ADT Security Services Security Manager 2000 user manual — SECURITY CODES
Page 25 · click to enlarge
Page 25

Quick Arming and Single-Button Arming

Babysitter Code This code can be used to arm the system in assigned partitions, but cannot disarm the system unless the system was armed with this code. This code is typically assigned to someone (such as a babysitter) who has a need to arm/disarm the system only at certain times. The babysitter code is assigned to user 15. The user of this code should not use the ÒQuick ArmingÓ feature described below.

Duress Code This feature is intended for use when you are forced to disarm or arm the system under threat. When used, the system will act normally, but can silently notify the Customer Care Center of your situation, if that service has been provided. Duress code is assigned to user 16. Important: This code is useful only when the system is connected to the Customer Care Center.

Note that if "Quick Arming" was programmed by the installer, the ÊÊ # Ê Ê key can be pressed in place of the security code when arming the system. If so programmed, the ÒAÓ and ÒBÓ keys on a touchpad can be used for single-button arming AWAY or STAY, respectively. See ARMING ALL PROTECTION and ARMING PERIMETER ONLY sections. The security code must always be used to disarm the system, however.

As an additional safety feature, other users who do not have a need to know your code can be assigned different security codes. These secondary users are identified by "user numbers," which are selected when assigning a user's security code. You can assign up 14 additional user codes (user numbers 03-16), including the babysitter and duress codes. Note that the master (primary) user of the system is the only one who can assign codes to secondary (or temporary) users, and is user number 02; user number 01 is reserved for the installer of the system. All codes can be used interchangeably when performing system functions (a system armed with one user's code can be disarmed by another user's code), with the exception of the babysitter code described below.

SECURITY CODES

General Information

Page 26 of the ADT Security Services Security Manager 2000 user manual — SECURITY CODES (Continued)
Page 26 · click to enlarge
Page 26

Changing your Master Code Follow this procedure: Enter your existing Master code + [8] + [0][2] + new Master code + new Master code again.

Ê CODE To Delete a User 1. ÊÊÊ + ÊÊÊ8ÊÊ Enter master code, then press CODE key.

To Add a User or Change a User's Code

SECURITY CODES (Continued)

(User Number) Enter the 2-digit User Number (03-16) for the user whose code you are deleting. 3. Stop. Wait (about 3 seconds) until the touchpad beeps once before pressing any other key. The code is automatically deleted.

2. ÊÊÊ ÊÊÊ Enter user number.
3. ÊÊÊ Enter user's code.
2. ÊÊÊ ÊÊÊ Enter user number. Enter the 2-digit User Number

CODE 1. ÊÊÊ + ÊÊÊ8ÊÊ Enter master code, then press CODE key.

Sequential key depressions for all steps in a procedure must be made within 2 seconds of one another, or else the entire entry is aborted and must be repeated from its beginning (e.g., perform steps 1, 2, and 3 below with no delay between steps).

(Master Code) Example: Ê7 Ê Ê2 Ê Ê9 Ê Ê6 Ê then press the CODE key.

(User's Code) Enter the new 4-digit security code for that user.

(User Number) (03-16) for the user you are adding or changing.

(Master Code) Example: Ê7 Ê Ê2 Ê Ê9 Ê Ê6 Ê then press the CODE key.

Page 27 of the ADT Security Services Security Manager 2000 user manual — AC
Page 27 · click to enlarge
Page 27

Using the Ê Ê5 ÊÊ TEST Key

4. Fault zones. Open each protected door and window in turn and listen for three beeps from the touchpad. Identification of each faulted protection point should appear on the display. The display will clear when the door or window is closed. (Continued)
3. Listen. The external sounder should sound for 1 second and then turn off. If the sounder does not sound, CALL FOR SERVICE IMMEDIATELY.

TEST 2. ÊÊÊ + ÊÊÊ5ÊÊÊ ÊEnter the security code, then press TEST key.

1. DISARM THE SYSTEM. Disarm the system and close all protected windows, doors, etc. The READY indicator light should come on if all zones are intact (i.e., all protected windows, doors, etc. are closed.

The TEST key puts your system into the Test mode, which allows each protection point to be checked for proper operation. The touchpad sounds a single beep every 40 seconds as a reminder that the system is in the Test mode. Note: An alarm message will not be sent to your Customer Care Center during the following tests.

ENGLISH DISPLAY TOUCHPAD

(Security Code) Example: Ê7 Ê Ê2 Ê Ê9 Ê Ê6 Ê then press the TEST key.

TESTING THE SYSTEM (TO BE CONDUCTED WEEKLY)

AC

CUSTOM DISPLAY TOUCHPAD

*** DISARMED *** READY TO ARM

Page 28 of the ADT Security Services Security Manager 2000 user manual — TESTING THE SYSTEM (CONTINUED)
Page 28 · click to enlarge
Page 28

OFF 5. ÊÊÊ + ÊÊÊ1ÊÊ EXIT TEST MODE ÊÊÊ(Security Code) Enter your security code and press the OFF key. If the test mode is inadvertently left active, it automatically turns off after 4 hours.

When testing is completed, exit the TEST mode by continuing with step 5.

Walk in front of any interior motion detectors (if used) and listen for three beeps. The identification of the detector should appear on the display when it is activated. The display will clear when no motion is detected. Note that if wireless motion detectors are used, there is a 3-minute delay between activations. This is to conserve battery life. To test all smoke detectors, follow the manufacturer's instructions. The identification of each detector should appear on the display when each is activated. If a problem is experienced with any protection point (no confirming sounds, no display), CALL FOR SERVICE IMMEDIATELY. When all protection points have been checked and are intact (closed), there should be no zone identification numbers displayed on the touchpad.

TESTING THE SYSTEM (CONTINUED)

Page 29 of the ADT Security Services Security Manager 2000 user manual — AC
Page 29 · click to enlarge
Page 29

* Not all systems use wireless sensors.

"Check" and "Battery" Displays

IF YOU CANNOT CORRECT A "CHECK" DISPLAY, CALL FOR SERVICE AT ONCE.

Ê ENGLISH DISPLAY TOUCHPAD

TYPICAL "CHECK" DISPLAYS 06

CHECK

The word CHECK on the touchpad's display, accompanied by a "beeping" at the touchpad, indicates a trouble condition in the system. To silence the beeping for these conditions, press any key. 1. A display of "CHECK" and one or more zone numbers indicates that a problem exists with the displayed zone(s) and requires your attention. Determine if the zone(s) displayed are intact and make them so if they are not. If the problem has been corrected, the display can be cleared if you enter the OFF sequence (security code plus OFF key) twice. If the display persists, CALL FOR SERVICE. Note: A display of CHECK 70 on English Display touchpads indicates that the wiring connection to the external sounder is at fault (opened or shorted), and you should CALL FOR SERVICE. See ÒBELL FAILUREÓ on the next page. A display of CHECK 90 indicates that RF interference may be impeding the operation of wireless sensors* in the system. See ÒRcvr JamÓ on the next page. 2. If there are wireless sensors* in your system, the CHECK condition may also be caused by some change in the environment that prevents the wireless receiver from hearing a particular sensor. CALL FOR SERVICE if this occurs.

TROUBLE CONDITIONS

AC

ÊÊÊÊCUSTOM ENGLISH DISPLAY

CHECK 06 BEDROOM WINDOW

Page 30 of the ADT Security Services Security Manager 2000 user manual — TROUBLE CONDITIONS (Continued)
Page 30 · click to enlarge
Page 30

** ÊNot all systems use wireless sensors.

* Any ÒbeepingÓ that accompanies a trouble display can be stopped by depress- ing any key on the touchpad or by entering an OFF sequence (code + OFF)

Words or letters in parentheses ( ) are those that are displayed on English Display Touchpads. m Other Trouble Displays

TROUBLE CONDITIONS (Continued)

6. BELL FAILURE Indicates that the wiring connection to the external sounder (or CHECK 70 ) is at fault (open or shorted). Accompanied by ÒbeepingÓ at the touchpad. CALL FOR SERVICE IMMEDIATELY.
5. MODEM COMM (or CC )
4. Rcvr Jam Wireless part of the system is experiencing RF interference (or CHECK 90 ) which may impede reception from wireless sensors.**
3. LO BAT + zone descriptor Indicates that there is a low battery condition in the wireless (or BAT with zone No.) transmitter** number displayed. Accompanied by a single "beep"* (once every 40 seconds) at the Touchpad. Either replace the battery yourself, or CALL FOR SERVICE. If the battery is not replaced within 30 days, a CHECK display may occur.
2. SYSTEM LO BAT Indicates that a low system battery condition exists. Display (or BAT with no zone No.) is accompanied by "beeping"* at the Touchpad. If this condition persists for more than one day (with AC present), CALL FOR SERVICE.
1. COMM. FAILURE Indicates that a failure has occurred in the telephone com- (or FC ) munication portion of your system. CALL FOR SERVICE IMMEDIATELY.

Indicates that the control is on-line with the Customer Care Center's remote computer. The control will not operate while on-line. Wait a few minutes. Display should disappear.

Page 31 of the ADT Security Services Security Manager 2000 user manual — TROUBLE CONDITIONS (Continued)
Page 31 · click to enlarge
Page 31

Total Power Failure If there is no touchpad display at all, and the READY indicator is not lit, operating power (from AC and back-up battery) for the system has stopped and the system is inoperative. CALL FOR SERVICE IMMEDIATELY.

In The Event Of Telephone Operational Problems In the event of telephone operational problems, disconnect the control from the phone line by removing the plug from the phone wall jack. We recommend that your installer demonstrate this disconnection on installation of the system. Do not attempt to disconnect the phone connection inside the control. Doing so will result in the loss of your phone lines. If the regular phones work correctly after the control has been disconnected from the phone wall jack, the control has a problem and you should immediately call for service. If upon disconnection of the control, there is still a problem on the phone line, notify the telephone company that they have a problem and request prompt phone repair service. The user may not under any circumstances attempt any service or repairs to the security system. Repairs must be made only by ADT authorized service (see the LIMITED WARRANTY statement for information on how to obtain service).

Other Trouble Displays (Continued)

TROUBLE CONDITIONS (Continued)

10. Long Rng Trbl If part of your system, back-up Long Range Radio com- (or bF ) munication has failed. CALL FOR SERVICE.
9. OPEN CIRCUIT The touchpad is not receiving signals from the control. (or OC ) CALL FOR SERVICE.
8. Busy-Standby (or dI )
7. AC LOSS is displayed The system is operating on battery power only due to an (or NO AC ) AC power failure. If only some lights are out on the premises, check circuit breakers and fuses and reset or replace as necessary. If AC power cannot be restored and a Òlow system batteryÓ message appears (see item 2 on the previous page), CALL FOR SERVICE .

If this remains displayed for more than 1 minute, system is disabled. CALL FOR SERVICE IMMEDIATELY.

Page 32 of the ADT Security Services Security Manager 2000 user manual — MAINTAINING YOUR SYSTEM
Page 32 · click to enlarge
Page 32

Wireless sensors may not have been used in your security system

Replacing Batteries in Wireless Sensors

Silencing Low Battery Warning Tones at the Touchpad

Taking Care of Your System

MAINTAINING YOUR SYSTEM

If you have a low battery in a wireless sensor, a low battery message i s displayed on the touchpad.

Each wireless sensor in your system has a 9-volt or 3-volt battery. The system detects a low battery in any wireless sensors, optional personal emergency transmitters, and optional portable wireless touchpads. (A low battery in a portable wireless touchpad is detected as soon as one of its keys is pressed, causing the wired touchpad to display Ò00Ó.) Alkaline batteries provide a minimum of 1 year of operation, and in most units and applications, provide 2Ð4 years of service. 3-volt lithium batteries provide up to 4 or more years of operation. Actual battery life will depend on the environment in which the sensor is used, the number of signals that the transmitter in the sensor has had to send, and the specific type of sensor. Factors such as humidity, high or low temperatures or large swings in temperature, may all lead to the reduction of actual battery life in an installation.

You can silence the touchpadÕs warning tones by pressing the OFF key, but the touchpad's low battery message display will remain on as a reminder that you have a low battery condition in one or more of your sensors. When you replace the weak battery with a fresh one, the sensor will send a "good battery" signal to the control as soon as the sensor is activated (opening/closing of door, window, etc.), causing the low battery display to turn off. If the sensor is not activated, the display will automatically clear within approximately 1 hour.

The components of your security system are designed to be as maintenance-free as possible. However, to make sure that your system is in reliable working condition. 1. Test your system weekly. 2. Test your system after any alarm occurs (see TESTING THE SYSTEM).

Page 33 of the ADT Security Services Security Manager 2000 user manual — MAINTAINING YOUR SYSTEM (Continued)
Page 33 · click to enlarge
Page 33

Routine Care ¥ Treat the components of your security system as you would any other electrical equipment. Do not slam sensor-protected doors or windows. ¥ Keep dust from accumulating on the touchpad and all protective sensors, particularly on motion sensors and smoke detectors. ¥ The touchpad and sensors should be cleaned carefully with a dry soft cloth. Do not spray water or any other fluid on the units.

MAINTAINING YOUR SYSTEM (Continued)

Page 34 of the ADT Security Services Security Manager 2000 user manual — QUICK GUIDE TO SYSTEM FUNCTIONS
Page 34 · click to enlarge
Page 34

Phone Access (Smartphone Module) if applicable

Press key [A], [B], or [C] for at least 2 seconds See the PANIC KEYS section for functions programmed for your system. Keys ÒAÓ and ÒBÓ may have been programmed for single-button arming (see ARMING PERIMETER ONLY and ARMING ALL PROTECTION sections). Chime Mode To turn ON or OFF: Enter code. Press CHIME key. Touchpad will sound if doors or windows are violated while system is disarmed and chime mode is ON. Test Mode To turn ON: Enter code. Press TEST key. To turn OFF: Enter code. Press OFF key.

Panic Alarms (as programmed)

Duress (if active and connected to Customer Care Center)

Also disarms system. Memory of alarm remains until cleared. Memory of Alarm remains until cleared. Determine cause. Disarm System Enter code. Press OFF key. Also silences sounders. Memory of alarm remains until cleared. Clear Alarm Memory After disarming, enter code again. Press OFF key again.

Silence Sounders BurglaryFire: "Check":

Quick Bypass (if programmed)

Bypass Zone(s) Enter code. Press BYPASS key. Enter zone number(s) to be bypassed (use 2-digit entries).

Quick Arm (if programmed)

FUNCTION PROCEDURE COMMENTS Check Zones Press READY key. To view faulted zones when system not ready. Arm System Enter code. Press arming key desired: (AWAY, STAY, INSTANT)

QUICK GUIDE TO SYSTEM FUNCTIONS

Consult Phone Access User's Guide that accompanies the Phone Module.

Arm or disarm "normally", but use your 4-digit Duress code to do so.

Enter code. Press OFF key. Press OFF key. Press any key.

Enter code. Press BYPASS key. Bypasses all faulted zones automatically.

Press #. Press arming key desired: (AWAY, STAY, INSTANT)

Permits system access remotely, via Touch-tone phone (see pages 6).

Tests alarm sounder and allows sensors to be tested.

Performs desired action and sends silent alarm to Customer Care Center.

Touchpad will beep rapidly upon entry if alarm has occurred. Alarm display will remain upon disarming until cleared.

Bypassed zones are unprotected and will not cause an alarm if violated.

Arms system in mode selected, quickly and without use of code.

Arms system in mode selected.

Page 35 of the ADT Security Services Security Manager 2000 user manual — (ENGLISH DISPLAY TOUCHPADS)
Page 35 · click to enlarge
Page 35
ADT Security Services Security Manager 2000 — SINGLE-BUTTON PAGING FEATURE diagram (page 35)
Fig. 8

b. Exceeding the entry delay time without disarming causes alarm. * If a bell is used as external sounder, burglary/audible emergency is steady ring.

ONE SHORT BEEP (once every 40 seconds) Touchpad only

SUMMARY OF AUDIBLE/VISUAL NOTIFICATIONS

a. EXIT DELAY WARNING (if ÊÊÊÊprogrammed) b. ENTRY DELAY WARNING

a. TROUBLE b. MEMORY OF ALARM c. SYSTEM LOW BATTERY d. EXT. SOUNDER WIRING FAIL.

b. ZONE OPENED WHILE SYSTEM ÊÊÊÊÊIS IN CHIME MODE.

ARM AWAY AWAY or INSTANT is displayed. Red ARMED indicator is lit.

a. SYSTEM IS IN TEST MODE b. LOW BATTERY AT A ÊÊÊÊTRANSMITTER

a. SYSTEM DISARM b. SYSTEM ARMING ATTEMPT ÊÊÊÊWITH AN OPEN ZONE.

(ENGLISH DISPLAY TOUCHPADS)

a. AWAY or AWAY & INSTANT is displayed.

a. CHECK displayed. Zone number of troubled protection zone is displayed. b. ALARM is displayed; zone number of zone in alarm is displayed c. BAT displayed with no zone ID number. d. CHECK 70 is displayed.

b. CHIME displayed; zone number of open protection zone will be displayed if ÊÊÊÊthe [,] key is pressed.

a. STAY or INSTANT is displayed. Red ARMED indicator is lit.

a. Opened zone numbers will appear. b. BAT displayed with zone number of transmitter.

c. Zone numbers of the bypassed protection zones are displayed (one beep is ÊÊÊÊheard for each zone displayed). Subsequently, the following is displayed: ÊÊÊÊBYPASS and READY

a. READY indicator light comes on when system is disarmed. b. The number of the open protection zone is displayed.

ALARM is displayed; zone number of zone in alarm is also displayed.

FIRE is displayed; zone number 95 is displayed.

Page 36 of the ADT Security Services Security Manager 2000 user manual — (CUSTOM ENGLISH DISPLAY TOUCHPADS)
Page 36 · click to enlarge
Page 36
ADT Security Services Security Manager 2000 — SINGLE-BUTTON PAGING FEATURE diagram (page 36)
Fig. 9

* If a bell is used as external sounder, fire alarm is pulsed ring; burglary/audible emergency is steady ring.

a. CHECK displayed. Descriptor of troubled protection zone is displayed. b.ALARM is displayed; descriptor of zone in alarm is displayed. c. SYSTEM LO BAT displayed. d. BELL FAILURE is displayed. SLOW BEEPING Touchpad only

c. Numbers and descriptors of the bypassed protection zones are displayed (One ÊÊÊÊbeep is heard for each zone displayed). Subsequently, the following is displayed: ÊÊÊÊDISARMED BYPASS Ready to Arm. ONE SHORT BEEP (once every 40 seconds) Touchpad only

SUMMARY OF AUDIBLE/VISIBLE NOTIFICATIONS

a. EXIT DELAY WARNING (if ÊÊÊÊprogrammed). b. ENTRY DELAY WARNING.

a. TROUBLE. b. MEMORY OF ALARM. c. SYSTEM LOW BATTERY. d. EXT. SOUNDER WIRING FAIL.

a. ARM STAY OR INSTANT. b. ZONE OPENED WHILE SYSTEM ÊIS IN CHIME MODE.

ARM AWAY. ARMED AWAY displayed. Red ARMED indicator lit.

a. SYSTEM IS IN TEST MODE. b, LOW BATTERY AT A ÊÊ TRANSMITTER.

a. SYSTEM DISARM. b. SYSTEM ARMING ATTEMPT ÊÊÊÊWITH AN OPEN ZONE.. c. BYPASS VERIFY.

(CUSTOM ENGLISH DISPLAY TOUCHPADS)

b. DISARM SYSTEM OR ALARM WILL OCCUR is displayed. Exceeding the ÊÊÊÊÊdelay time without disarming causes alarm.

a. ARMED AWAY is displayed along with You May Exit Now.

a. ARMED STAY or ARMED INSTANT displayed. Red ARMED indicator lit. b. CHIME displayed, descriptor of open protection zone will be displayed if the [,] ÊÊÊÊkey is pressed.

a. Opened Zone identifications will appear. b. LO BAT displayed with description of transmitter.

a. DISARMED/READY TO ARM is displayed. b. The number and descriptor of the open protection zone is displayed.

ALARM is displayed. If programmed, descriptor of zone in alarm is also displayed.

FIRE is displayed;; zone number 95 is displayed

Page 37 of the ADT Security Services Security Manager 2000 user manual — FEDERAL COMMUNICATIONS COMMISSION (FCC) Part 15 STATEMENT
Page 37 · click to enlarge
Page 37

The user shall not make any changes or modifications to the equipment unless authorized by the Installation Instructions or User's Manual. Unauthorized changes or modifications could void the user's authority to operate the equipment.

If necessary, the user should consult the dealer or an experienced radio/television technician for additional suggestions. The user or installer may find the following booklet prepared by the Federal Communications Commission helpful: "Interference Handbook". This booklet is available from the U.S. Government Printing Office, Washington, DC 20402.

This equipment generates and uses radio frequency energy and if not installed and used properly, that is, in strict accordance with the manufacturer's instructions, may cause interference to radio and television reception. It has been type tested and found to comply with the limits for a Class B computing device in accordance with the specifications in Part 15 of FCC Rules, which are designed to provide reasonable protection against such interference in a residential installation. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: ¥ If using an indoor antenna, have a quality outdoor antenna installed. ¥ Reorient the receiving antenna until interference is reduced or eliminated. ¥ Increase the separation between the radio or television receiver and the alarm control. ¥ Move the antenna leads away from any wire runs to the alarm control. ¥ Plug the radio or television receiver into a different outlet so that they are on different branch circuit than the alarm control.

This equipment has been tested to FCC requirements and has been found acceptable for use. The FCC requires the following statement for your information:

FEDERAL COMMUNICATIONS COMMISSION (FCC) Part 15 STATEMENT

UL NOTICE: This is a "Grade A" Residential System.

Page 38 of the ADT Security Services Security Manager 2000 user manual — FEDERAL COMMUNICATIONS COMMISSION (FCC) Part 68 STATEMENT
Page 38 · click to enlarge
Page 38

This equipment complies with Part 68 of the FCC rules. On the front cover of this equipment is a label that contains, among other information, the FCC registration number and ringer equivalence number (REN) for this equipment. If requested, this information must be provided to the telephone company. This equipment uses the following jacks:ÊÊAn RJ31X is used to connect this equipment to the telephone network. The REN is used to determine the quantity of devices which may be connected to the telephone line. Excessive RENs on the telephone line may result in the devices not ringing in response to an incoming call. In most, but not all areas, the sum of the RENs should not exceed five (5.0). To be certain of the number of devices that may be connected to the line, as determined by the total RENs, contact the telephone company to determine the maximum REN for the calling area. If this equipment causes harm to the telephone network, the telephone company will notify you in advance that temporary discontinuance of service may be required. If advance notice is not practical, the telephone company will notify the customer as soon as possible. Also, you will be advised of your right to file a complaint with the FCC if you believe necessary. The telephone company may make changes in its facilities, equipment, operations, or procedures that could affect the operation of the equipment. If this happens, the telephone company will provide advance notice in order for you to make the necessary modifications in order to maintain uninterrupted service. If trouble is experienced with this equipment, please contact the manufacturer for repair and warranty information. If the trouble is causing harm to the telephone network, the telephone company may request you remove the equipment from the network until the problem is resolved. There are no user serviceable components in this product, and all necessary repairs must be made by the manufacturer. Other repair methods may invalidate the FCC registration on this product. This equipment cannot be used on telephone company-provided coin service. Connection to Party Line Service is subject to state tariffs. This equipment is hearing-aid compatible. When programming or making test calls to an emergency number, briefly explain to the dispatcher the reason for the call. Perform such activities in the off-peak hours; such as early morning or late evening.

FEDERAL COMMUNICATIONS COMMISSION (FCC) Part 68 STATEMENT

Page 39 of the ADT Security Services Security Manager 2000 user manual — CANADIAN DEPARTMENT OF COMMUNICATIONS (DOC) STATEMENT
Page 39 · click to enlarge
Page 39

The Load Number (LN) assigned to each terminal device denotes the percentage of the total load to be connected to a telephone loop which is used by the device, to prevent overloading. The termination on a loop may consist of any combination of devices subject only to the requirement that the total of the Load Numbers of all the devices does not exceed 100.

Users should ensure for their own protection that the electrical ground connections of the power utility, telephone lines and internal metallic water pipe system, if present, are connected together. This precaution may be particularly important in rural areas.

NOTICE The Canadian Department of Communications label identifies certified equipment. This certification means that the equipment meets certain telecommunications network protective, operational and safety requirements. The Department does not guarantee the equipment will operate to the user's satisfaction. Before installing this equipment, users should ensure that it is permissible to be connected to the facilities of the local telecommunications company. The equipment must also be installed using an acceptable method of connection. In some cases, the company's inside wiring associated with a single line individual service may be extended by means of certified connector assembly (telephone extension cord). The customer should be aware that compliance with the above conditions may not prevent degradation of service in some situations. Repairs to certified equipment should be made by an authorized Canadian maintenance facility designated by the supplier. Any repairs or alterations made by the user to this equipment, or equipment malfunctions, may give the telecommunications company cause to request the user to disconnect the equipment.

CANADIAN DEPARTMENT OF COMMUNICATIONS (DOC) STATEMENT

  • AVIS L'Žtiquette du minist
  • re des Communications du Canada identifie le matŽriel homologuŽ. Cette Žtiquette certifie que le matŽriel est conforme ˆ certaines normes de protection, d'exploitation et de sŽcuritŽ des rŽseaux de tŽlŽcommunications. Le minist
  • re n'assure toutefois pas que le matŽriel fonctionnera ˆ la satisfaction de l'utilisateur. Avant d'installer ce matŽriel, l'utilisateur doit s'assurer qu'il est permis de le raccorder aux installations de l'entreprise locale de tŽlŽcommunications. Le matŽriel doit Žgalement
  • tre installŽ en suivant une mŽthode acceptŽe de raccordement. Dans certains cas, les fils intŽrieurs de l'entreprise utilisŽs pour un service individuel ˆ la ligne unique peuvent
  • tre prolongŽs au moyen d'un dispositif homologuŽ de raccordement (cordon prolongateur tŽlŽphonique interne). L'abonne ne doit pas oublier qu'il est possible que la conformitŽ aux conditions ŽnoncŽes ci-dessus n'emp
  • che pas la dŽgradation du service dans certaines situations. Actuellement, les entreprises de tŽlŽcommunications ne permettent pas que l'on raccorde leur matŽriel aux prises d'abonnŽs, sauf dans les cas precis prŽvus par les tarifs particuliers de ces entreprises. Les rŽparations du matŽriel homologuŽ doivent
  • tre effectuŽes pas un centre d'entretien canadien autorisŽ dŽsignŽ par le fournisseur. La compagnie de tŽlŽcommunications peut demander ˆ l'utilisateur de dŽbrancher un appareil ˆ la suite de rŽparations ou de modifications effectuŽes par l'utilisateur ou ˆ cause de mauvais fonctionnement. Pour sa propre protection, l'utilisateur doit s'assurer que tous les fils de mise en terre de la source d'Žnergie Žlectrique, des lignes tŽlŽphoniques de rŽseau de conduites d'eau, s'il y en a, soient raccordŽs ensemble. Cette prŽcaution est particuli
  • rement importante dans les rŽgions rurales. Avertissement: L'utilisateur ne doit pas tenter de faire ces raccordements luim
  • me; il doit avoir recours ˆ un service d'inspection des installations Žlectriques, ou ˆ un Žlectricien, selon le cas. L'indice de charge (IC) assignŽ ˆ chaque dispositif terminal pour Žviter toute surcharge indique le pourcentage de la charge totale qui peut
  • tre raccordŽ ˆ un circuit tŽlŽphonique fermŽ utilisŽ par ce dispositif. La terminaison du circuit fermŽ peut
  • tre constituŽe de n'importe quelle combinaison de dispositifs, pourvu que la somme des indices de charge de l'ensemble des dispositifs ne dŽpasse pas 100.
Page 40 of the ADT Security Services Security Manager 2000 user manual — WARNING! THE LIMITATIONS OF THIS ALARM SYSTEM
Page 40 · click to enlarge
Page 40

While this system is an advanced design security system, it does not offer guaranteed protection against burglary or other emergency. Any alarm system, whether commercial or residential, is subject to compromise or failure to warn for a variety of reasons. For example: ¥ Intruders may gain access through unprotected openings or have the technical sophistication to bypass an alarm sensor or disconnect an alarm warning device. ¥ Intrusion detectors (e.g. passive infrared detectors), smoke detectors, and many other sensing devices will not work without power. Battery operated devices will not work without batteries, with dead batteries, or if the batteries are not put in properly. Devices powered solely by AC will not work if their AC power supply is cut off for any reason, however briefly. ¥ Signals sent by wireless transmitters may be blocked or reflected by metal before they reach the alarm receiver. Even if the signal path has been recently checked during a weekly test, blockage can occur if a metal object is moved into the path. ¥ A user may not be able to reach a panic or emergency button quickly enough. ¥ Passive Infrared Motion Detectors can only detect intrusion within the designed ranges as diagrammed in their installation manual. Passive Infrared Detectors do not provide volumetric area protection. They do create multiple beams of protection, and intrusion can only be detected in unobstructed areas covered by those beams. They cannot detect motion or intrusion that takes place behind walls, ceilings, floors, closed doors, glass partitions, glass doors, or windows. Mechanical tampering, masking, painting or spraying of any material on the mirrors, windows or any part of the optical system can reduce their detection ability. Passive Infrared Detectors sense changes in temperature; however, as the ambient temperature of protected area approaches the temperature range of 32° to 40°C (90° to 105°F), the detection performance can decrease.

WARNING! THE LIMITATIONS OF THIS ALARM SYSTEM

(Continued)

Page 41 of the ADT Security Services Security Manager 2000 user manual — SINGLE-BUTTON PAGING FEATURE
Page 41 · click to enlarge
Page 41

¥ Alarm warning devices such as sirens, bells or horns may not alert people or wake up sleepers if they are located on the other side of closed or partly open doors. If warning devices sound on a different level of the residence from the bedrooms, then they are less likely to waken or alert people inside the bedrooms. Even persons who are awake may not hear the warning if the alarm is muffled from a stereo, radio, air conditioner or other appliance, or by passing traffic. Finally, alarm warning devices, however loud, may not warn hearing-impaired people or waken deep sleepers. ¥ Telephone lines needed to transmit alarm signals from a premises to a central monitoring station may be out of service or temporarily out of service. Telephone lines are also subject to compromise by sophisticated intruders. ¥ Even if the system responds to the emergency as intended, however, occupants may have insufficient time to protect themselves from the emergency situation. In the case of a monitored alarm system, authorities may not respond appropriately. ¥ This equipment, like other electrical devices, is subject to component failure. Even though this equipment is designed to last as long as 10 years, the electronic components could fail at any time. The most common cause of an alarm system not functioning when an intrusion or fire occurs is inadequate maintenance. This alarm system should be tested weekly to make sure all sensors and transmitters are working properly. Installing an alarm system may make one eligible for lower insurance rates, but an alarm system is not a substitute for insurance. Homeowners, property owners and renters should continue to act prudently in protecting themselves and continue to insure their lives and property. We continue to develop new and improved protection devices. Users of alarm systems owe it to themselves and their loved ones to learn about these developments.

Page 42 of the ADT Security Services Security Manager 2000 user manual — Terms and Conditions Applying to Sale of Equipment
Page 42 · click to enlarge
Page 42

1. Limited Warranty. Any part of the system, including the wiring, installed under this Agreement which proves to be defective in material or workmanship within 90 days of the date of completion of installation will be repaired or replaced at ADT's option with a new functionally operative part. Labor and material required to repair or replace such defective components or to make mechanical adjustments to the system will be free of charge for a period of 90 days following the completion of the original installation. This warranty is extended only to the original consumer purchaser of the system and may be enforced only by such person. To obtain service under this warranty, call or write our local ADT Service Department at the telephone number or address found in your local yellow pages. Service pursuant to the warranty will be furnished only during ADT's normal working hours 8:00A.M. to 4:30P.M., Monday through Friday, except holidays. Services rendered outside the normal working hours of ADT are not within the scope of this warranty and any services requested to be performed at such times shall be charged for at ADT's then applicable rates for labor and material. This warranty does not apply to the conditions listed below, and in the event customer calls ADT for service under the warranty and upon inspection it is found that one of these conditions has led to the inoperability or apparent inoperability of the system, a charge will be made for the service call of the ADT representative, whether or not he actually works on the system. Should it actually be necessary to make repairs to the system due to one of the "conditions Not Covered By Warranty", a charge will be made for such work at ADT's then applicable rates for labor and material. Conditions Not Covered By Warranty. A. Damage from accidents, acts of God, alterations, misuse, tampering or abuse. B. Failure of the customer to properly close or secure a door, window, or other point protected by a burglar alarm device. C. Failure of customer to properly follow operating instructions provided by ADT at time of installation or at a later date. D. Trouble in leased telephone. E. Trouble due to interruption of commercial power. F. Battery replacements.

LIMITED WARRANTY

Terms and Conditions Applying to Sale of Equipment

Page 43 of the ADT Security Services Security Manager 2000 user manual — –––––––––––––––––––––––––––––– Ê ALL RIGHTS RESERVED Ê ––––––––––––––––––––––––––––––
Page 43 · click to enlarge
Page 43

No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form, or by any means Ð electronic, mechanical, photocopying, recording, or otherwise without the written permission of ADT Security Systems, Inc. The material in this publication is for information purposes and subject to change without notice. ADT Security Systems, Inc. assumes no responsibility for any errors which may appear in this publication.

Ê ALL RIGHTS RESERVED Ê

2. Installation. ADT agrees to install the equipment in a workmanlike manner in accordance with the following conditions: A. Customer will make premises available without interruption during ADT normal working hours 8:00A.M. to 4:30P.M., Monday through Friday, except Holidays. B. Customer understands that the installation will necessitate drilling into various parts of the premises: ADT intends, generally, to conceal wiring in the finished areas of the premises; however, there may be areas which, due to construction, decoration, or furnishing of the premises, ADT determines, in its sole discretion, that it would be impractical to conceal wiring and, in such cases, wiring will be exposed. C. Customer agrees to provide 110 VAC electrical outlets at designated locations for equipment requiring AC power. D. Customer to provide for lifting and replacing carpeting, if required, for installation of floor mats or wiring.

This warranty is in lieu of all other express warranties. Any implied warranties of merchantability and fitness for a particular purpose are limited in duration to a period of 90 days from the date of completion of installation. The exclusive remedy of the customer hereunder shall be repair or replacement as stated above. Under no circumstances shall ADT be liable to the customer or any other person for incidental or consequential damages of any nature, including without limitation, damages for personal injury or damages to property, and, however occasioned, whether alleged as resulting from breach of warranty by ADT, the negligence of ADT, or otherwise, ADT's liability will in no event exceed the purchase price of the system. Some states may not allow limitations on how long an implied warranty lasts, or the exclusion or limitations of incidental or consequential damages, so the above limitations and exclusions may not apply to you, unless a longer period is required by applicable law. Any action against ADT in connection with a system must be commenced within one year after the cause of action has occurred. No agent, employee or representative of ADT nor any other person is authorized to modify this warranty in any respect. This warranty gives you specific legal rights and you may also have other rights which vary from state to state.

Page 44 of the ADT Security Services Security Manager 2000 user manual — N7527-6V2 4/99
Page 44 · click to enlarge
Page 44

N7527-6V2 4/99

àN7527-6V2Dä

ADT Security Services, Inc. · One Town Center Rd. · Boca Raton, FL 33486

ADT Security Services Security Manager 2000 — N7527-6V2 4/99 diagram (page 44)
Fig. 10

Copyright © 1999

Ask about the ADT Security Services Security Manager 2000

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the ADT Security Services Security Manager 2000

Be the first to ask — other owners or our team will answer.

Original document

ADT Security Services Security Manager 2000 manual PDF

44 pages·215 KB·Home Security System·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…