www.moxa.com/product

© 2021 Moxa Inc. All rights reserved.

The software described in this manual is furnished under a license agreement and may be used only in accordance
with the terms of that agreement.
© 2021 Moxa Inc. All rights reserved.
The MOXA logo is a registered trademark of Moxa Inc.
All other trademarks or registered marks in this manual belong to their respective manufacturers.
Information in this document is subject to change without notice and does not represent a commitment on the part of
Moxa.
Moxa provides this document as is, without warranty of any kind, either expressed or implied, including, but not
limited to, its particular purpose. Moxa reserves the right to make improvements and/or changes to this manual, or to
the products and/or the programs described in this manual, at any time.
Information provided in this manual is intended to be accurate and reliable. However, Moxa assumes no responsibility
for its use, or for any infringements on the rights of third parties that may result from its use.
This product might include unintentional technical or typographical errors. Changes are periodically made to the
information herein to correct such errors, and these changes are incorporated into new editions of the publication.
Moxa China (Shanghai office)

1. Introduction ...................................................................................................................................... 1-1
Overview 1-2 Package Checklist 1-2 Product Features 1-2 Hardware Specifications 1-3
Appearance ........................................................................................................................................ 2-2
DA-662A-8 Models 2-2 DA-662A-16 Models 2-2 Dimensions 2-3 Hardware Block Diagram 2-3
DA-662A-8 Models 2-3 DA-662A-16 Models 2-4 LED Indicators 2-4 Reset Button 2-4 LCD Screen 2-5 Push Buttons 2-5 Real-time Clock 2-5
Placement Options .............................................................................................................................. 3-2
Rack Mounting ............................................................................................................................ 3-2 Connecting the Hardware .................................................................................................................... 3-2
Wiring Requirements 3-2 Connecting the Power 3-2 Connecting to the Network 3-3 Connecting to a Serial Device 3-3 Configurable Pull High/Low Resistors for the RS-485 Port 3-4 Connecting to the Console Port 3-5 USB Host 3-5 CompactFlash 3-5


The DA-660A Series embedded computers come with 8 to 16 software selectable RS-232/422/485 serial
ports, making them suitable for a variety of industrial applications. Models with 4 10/100 Mbps Ethernet
ports are also available. The DA-660A also comes with CF and USB ports to make it easy to add additional
storage space. The computers are designed with a standard 19-inch, rugged 1U rackmount case, and are
embedded with a 100-240 VAC power input. This combination of features gives users a robust and reliable
ready-to-run solution for applications such as data acquisition and power substations.
The following topics are covered in this chapter:

Overview
The DA-660A Series computers are RISC-based, ready-to-run embedded computers designed for industrial
data acquisition applications. The models have either 8 or 16 RS-232/422/485 serial ports, and 2 USB hosts
based on the Moxa Macro 500 MHz communication processor. The DA-660A has 4 Ethernet ports. The
casing is a standard 1U, 19-inch-wide rack-mounted rugged enclosure. The robust, rack-mountable design
provides the hardened protection needed for industrial environment applications and makes it easy for users
to install the DA-660A on a standard 19-inch rack. The DA-660A Series computers are ideal for applications
that require a distributed embedded technology, such as SCADA systems, plant floor automation, and power
electricity monitoring applications.
The DA-660A Series computers are suitable for IT control room applications, the critical assets used in the
control and automation system of industrial plant floors, and in electric power utility substations. The
computers can accept a wide range of power inputs (from 100 to 240V), which means that they can be
connected to AC power lines. Because of the no-hard-disk, fanless, and energy-efficient design, the
computers minimize heat generation, can operate around the clock, year in and year out, in heavy duty,
harsh industrial environments, delivering the kind of reliable computing power expected of a multifunctional
controller.
You can choose DA-660A Series models that come preinstalled with the open-standard Linux OS. The built-
in SDK makes program development easy by allowing you to follow the common programming procedures
used on a standard PC. The software you develop for your own applications can be stored in the onboard
Flash memory. The DA-660A Series embedded computers are ideal for creating control systems with
distributed architecture that are based on embedded technologies. Typical applications include SCADA
systems, plant floor automation, and power electricity monitoring.
Before installing the DA-660A Series, verify that the package contains the following items:

Hardware Specifications

The DA-660A Series hardware is compact, well-designed, and built for rugged industrial applications. LED
indicators help you monitor the performance and identify trouble spots. Multiple ports allow the connection
of different devices for wireless operation. With the reliable and stable hardware platform that is provided,
you can devote your attention to the development of your application. In this chapter, learn the basics
about the embedded computer hardware and its different parts.
The following topics are covered in this chapter:







The following block diagrams show the layout of the internal components of the DA-660A Series.

Unit = mm


LED indicators are located on the front panel of the DA-660A Series.

Press the Reset button on the front panel continuously for at least 5 seconds to load the factory default
configuration. After the factory default configuration has been loaded, the system will reboot
automatically. The Ready LED will blink on and off for the first 5 seconds, and then maintain a steady glow
once the system has rebooted.
We recommend that you only use this function if the software is not working properly, and you want to load
factory default settings. To reset an embedded Linux system, always use the software reboot command
/>reboot to protect the integrity of data being transmitted or processed. The Reset button is not designed
to hard reboot the DA-660A Series.

Pressing the Reset button will only load the configuration file. All files in the /etc directory will revert to
their factory defaults, and all user data in the Flash ROM will be deleted.

The DA-660A Series has an LCD screen on the front panel. The LCD screen can display 16 columns and 2
rows of text. After the computer boots up, the LCD screen will display the model name and firmware version
as indicated in the table below:
D A - 6 6 2 A - 1 6
Push Buttons
There are four push buttons located on the front panel. The buttons are used to enter text onto the LCD
screen. The buttons are MENU, (up cursor), (down cursor), and SEL:
The real time clock is powered by a lithium battery. We strongly recommend that you do not replace the
lithium battery without help from a qualified Moxa support engineer. If you need to change the battery,
contact the Moxa RMA service team.
There is a risk of explosion if the battery is replaced by an incorrect type.

The following topics are covered in this chapter:
Connecting to the Network
Connecting to a Serial Device
Configurable Pull High/Low Resistors for the RS-485 Port
Connecting to the Console Port

Rack Mounting
The DA-660A Series is designed to be mounted on a standard 19-inch rack. Two L-shaped metal plates are
included as standard accessories with the computer. Use the enclosed pair of L-shaped metal plates and
screws to fasten your computer to the rack cabinet. Two placement options are available. You can either
lock the front or the rear panel of the computer to the front of the rack. Each L-shaped plate has 6 holes,
leaving two outer or inner holes open for your convenience.
This section describes how to connect the DA-660A Series to serial devices. The topics covered in this
to a Serial Device, and Connecting to the Console Port.
Be sure to disconnect the power cord before installing and/or wiring your DA-660A Series.
Calculate the maximum possible current in each power wire and common wire. Observe all electrical codes
dictating the maximum current allowable for each wire size.
If the current goes above the maximum ratings, the wiring could overheat, causing serious damage to your
equipment.
Be careful when handling the DA-660A Series. When plugged in, the DA-660A series’ internal components
generate heat, and consequently the outer casing may feel hot to the touch.
You should observe the following common wiring rules:
cross, make sure the wires are perpendicular at the intersection point.
interference, wires with different signal characteristics should be routed separately.
separate. The rule of thumb is that wiring that shares similar electrical characteristics can be bundled
together.
To power on the DA-660A Series, use a power cord to connect the power line to the AC power connector on
the computer. The power connector is located on the right side of the rear panel. Next, turn on the power
switch. The DA-660A takes about 30 seconds to boot up. Once the device is ready, the Ready LED on the
front panel will light up, and model name and firmware version will appear on the LCD screen.
Safety First! · Wiring Caution! · Temperature Caution!

Connect one end of the Ethernet cable to one of the 10/100M Ethernet ports (8-pin RJ45) on the computer
and the other end of the cable to the Ethernet network. If the cable is properly connected, the computer will
indicate a valid connection to the Ethernet in the following ways:
Use properly wired serial cables to connect the DA-660A to serial devices. The serial ports (P1 to P16) on
the DA-660A use 8-pin RJ45 connectors. The ports can be configured by software for RS-232, RS-422, or 2-
wire RS-485. The pin assignments are shown in the following table:



In some critical environments, you may need to add termination resistors to prevent the reflection of serial
signals. When using termination resistors, it is important to set the pull high/low resistors correctly so that
the electrical signal is not corrupted. The DA-660A uses jumper settings to set the termination resistors and
pull high/low resistor values for each serial port.
To configure the termination and pull high/low resistors for the serial connections, you first need to open the
chassis if the computer. You will see 3 rows of jumper caps (as shown in the accompanying figure). The first
row is for setting pull high resistors, the second row is for setting termination resistors, and the third row is
for setting pull low resistors.
Each serial port has 6 jumper caps for configuring the resistors. The pin assignments are shown in the
following table:
RS485 Data + RS485 Data -
To set the termination resistors to 120 Ω, make sure that PIN 2 and PIN 3 assigned to the serial port are
shorted by jumper caps.
To set the pull high/low resistors to 150 kΩ, make sure that PIN 1 and PIN 2 assigned to the serial port are
shorted by jumper caps. This is the default setting.
To set the pull high/low resistors to 1 kΩ, make sure that PIN 2 and PIN 3 assigned to the serial port are
shorted by jumper caps.

Do not use the 1 KΩ setting on the DA-660A when using the RS-232 interface. Doing so will degrade the
RS-232 signals, shorten the maximum allowed communication distance, and the Rx LED may light up.
The console port on the DA-660A is an 8-pin RJ45 RS-232 port. The pin definition is the same as for the
serial ports (P1 to P16).
The DA-660A offers 2 USB 2.0 hosts, allowing you to connect with a USB storage device. The first USB mass
storage device to be connected will be mounted automatically to /mnt/sdc and the second device will be
mounted to /mnt/sdd using the mount command. The storage device will be un-mounted automatically
with the umount command when it is disconnected.
The DA-660A Series computers have a built-in CompactFlash socket. The CompactFlash socket allows users
to add additional memory by inserting a CompactFlash memory card, without any risk to the computer.
Follow the instructions below to insert a CompactFlash card:
The DA-660A Series computers do not support CompactFlash hot swap and PnP (Plug and Play) function.
You MUST turn off the DA-660A before inserting or removing the CompactFlash card.
Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.