EN
Hilti logo
Official user manual

Hilti Laser Range Meter (PD-E)

76 pages·420 KB·Power Tools·PDF·ENDEITNLJA
Hilti Laser Range Meter (PD-E)
Table of Contents 68 sections English · 1 Information about the operating instructions · 1.1 About these operating instructions · 1.2 Explanation of symbols · … ShowHide
Englishp.51 Information about the operating instructionsp.51.1 About these operating instructionsp.51.2 Explanation of symbolsp.51.2.1 Warningsp.51.2.2 Symbols in the operating instructionsp.51.2.3 Symbols in illustrationsp.61.3 Product-dependent symbolsp.61.3.1 General symbolsp.61.4 Product informationp.61.5 Laser information on the productp.72 Safetyp.72.1 Safety instructionsp.72.1.1 Basic information concerning safetyp.72.1.2 General safety rulesp.82.1.3 Proper preparation of the working areap.82.1.4 Working safely with laser toolsp.82.1.5 Electromagnetic compatibilityp.93 Descriptionp.93.1 Overview of the productp.93.2 Intended usep.93.3 Explanation of the displayp.103.4 Items suppliedp.124 Technical datap.125 Operationp.135.1 Basic functionsp.135.2 Inserting the batteriesp.135.3 Switching the laser range meter on and offp.135.4 Measuring using the spikep.135.5 Measuring using a target platep.145.6 Measurement modep.145.6.1 Single measurementsp.145.6.2 Continuous measurementp.145.7 Selecting the angle unitp.145.8 Measuring areas and volumesp.155.8.1 Measuring rectangular areasp.155.8.2 Measuring triangular areasp.155.8.3 Measuring volumesp.155.8.4 Measuring cylindrical volumep.155.9 Special functionsp.155.9.1 Automatic brightness sensorp.155.9.2 Painter’s areap.155.9.3 Layout functionp.165.9.4 Min/max delta functionp.165.9.5 Data storagep.175.10 Trapezoidp.175.10.1 Trapezoid function (3 distances)p.175.10.2 Trapezoid with inclination (2 distances, 1 angle)p.175.11 Pythagorasp.175.11.1 Single Pythagorasp.175.11.2 Double Pythagorasp.175.11.3 Combined Pythagorasp.175.12 Settingsp.185.12.1 Editing the favorites listp.185.12.2 Activating the scalep.185.12.3 Calibrate inclination sensorp.185.13 Indirect measurementsp.185.13.1 Indirect horizontal distance measurementp.185.13.2 Indirect vertical distance (2 angles, 2 distances)p.185.13.3 Taking measurements on ceilingsp.185.13.4 Indirect vertical distance II (2 angles, 1 distance)p.196 Care, transport and storagep.196.1 Cleaningp.196.2 Transportp.196.3 Storage and dryingp.197 Disposalp.198 FCC statement / IC statementp.209 Manufacturer’s warrantyp.20
Page 1 of the Hilti Laser Range Meter (PD-E) user manual — PD-E
Page 1 · click to enlarge
Page 1
Hilti Laser Range Meter (PD-E) diagram (page 1)
Fig. 1

English 1 Français 17 Español 34 Português 51

PD-E

Page 2 of the Hilti Laser Range Meter (PD-E) user manual
Page 2 · click to enlarge
Page 2
Hilti Laser Range Meter (PD-E) diagram (page 2)
Fig. 2
Page 3 of the Hilti Laser Range Meter (PD-E) user manual
Page 3 · click to enlarge
Page 3
Hilti Laser Range Meter (PD-E) diagram (page 3)
Fig. 3
Hilti Laser Range Meter (PD-E) diagram (page 3)
Fig. 4
Hilti Laser Range Meter (PD-E) diagram (page 3)
Fig. 5
Page 4 of the Hilti Laser Range Meter (PD-E) user manual — PD-E
Page 4 · click to enlarge
Page 4

PD-E

en English 1 fr Français 17 es Español 34 pt Português 51

Page 5 of the Hilti Laser Range Meter (PD-E) user manual — 1 Information about the operating instructions
Page 5 · click to enlarge
Page 5

1 Information about the operating instructions

1.1 About these operating instructions

  • Read these operating instructions before the product is used or operated for the first time. This is a prerequisite for safe, trouble-free handling and use of the product.
  • Observe the safety instructions and warnings in these operating instructions and on the product.
  • Always keep the operating instructions with the product and make sure that the product is accompanied by these operating instructions only, when the product is given to other persons.

1.2 Explanation of symbols

1.2.1 Warnings Warnings alert persons to hazards that occur when handling or using the product. The following signal words are used:

1.2.2 Symbols in the operating instructions The following symbols are used in these operating instructions:

Comply with the operating instructions

Instructions for use and other useful information

Dealing with recyclable materials

Do not dispose of electric equipment and batteries as household waste

Page 6 of the Hilti Laser Range Meter (PD-E) user manual — KCCREM-HLTPD-E
Page 6 · click to enlarge
Page 6

1.2.3 Symbols in illustrations The following symbols are used in illustrations:

These numbers refer to the illustrations at the beginning of these operating instructions.

The numbers in illustrations refer to important work steps or to com- ponents important for the work steps. In the text, the corresponding numbers draw attention to these work steps or components, e.g. (3).

Item reference numbers are used in the overview illustration and refer to the numbers used in the key in the product overview sec- tion.

This symbol is intended to draw your special attention to certain points for handling the product.

1.3 Product-dependent symbols

1.3.1 General symbols Symbols used in relation to the product.

If applied on the product, the product has been certified by this cer- tification body for the US and Canadian markets according to the applicable standards.

KCCREM-HLTPD-E

1.4 Product information

products are designed for professional users and only trained, authorized personnel are permitted to operate, service and maintain the products. This personnel must be specifically informed about the possible hazards. The product and its ancillary equipment can present hazards if used incorrectly by untrained personnel or if used not in accordance with the intended use. The type designation and serial number are printed on the rating plate.

Show 6 more labels / short text on this page
On/off button · Measure button · Menu button · Delete (clear) button · Right arrow button · Left arrow button
Page 7 of the Hilti Laser Range Meter (PD-E) user manual — 2 Safety
Page 7 · click to enlarge
Page 7

▶ Write down the serial number in the table below. You will be required to state the product details when contacting Hilti Service or your local Hilti organization to inquire about the product. Product information

Laser range meterPD-E Generation01 Serial no.

1.5 Laser information on the product

Laser information →page 3 Laser information

Laser Class 2 based on the IEC60825-1 / EN60825- 1:2007 standard in compliance with CFR 21 § 1040 (Laser Notice 50).

Laser Class 2: Do not stare into the beam. Do not di- rect the beam toward other persons or toward areas in which other persons, who are not involved in the work with lasers, may be present.

Recycle waste material.

2 Safety

2.1 Safety instructions

2.1.1 Basic information concerning safety In addition to the safety rules listed in the individual sections of these operating instructions, the following rules must be strictly observed at all times. The product and its ancillary equipment may present hazards when used incorrectly by untrained personnel or when used not as directed. ▶ Keep all safety instructions and information for future reference. ▶ Stay alert, watch what you are doing and use common sense when working with the product. Do not use the product while you are tired or under the influence of drugs, alcohol or medication. A moment of inattention while operating the product may result in serious personal injury. ▶ Do not render safety devices ineffective and do not remove information and warning notices. ▶ If the product is opened improperly, laser radiation in excess of Class 2 may be emitted. Have the product repaired only by Hilti Service. ▶ Tampering with or modification of the product is not permitted. ▶ Check that the product functions correctly each time before use.

Page 8 of the Hilti Laser Range Meter (PD-E) user manual — 2.1.2 General safety rules
Page 8 · click to enlarge
Page 8

▶ Measurements taken through panes of glass or other objects may be inaccurate. ▶ The measurement may be incorrect if the conditions under which the measurement is taken change rapidly, e.g. due to people walking through the path of the laser beam. ▶ Do not point the product toward the sun or other powerful light sources. ▶ Take the influences of the surrounding area into account. Do not use the tool where there is a risk of fire or explosion. ▶ Observe the information printed in the operating instructions concerning operation, care and maintenance.

2.1.2 General safety rules ▶ Check the product for damage before use. Have the damage repaired by Hilti Service. ▶ Check the accuracy of the product after it has been dropped or subjected to other mechanical stresses. ▶ Although the product is designed for the tough conditions of jobsite use, as with other measuring instruments it should be treated with care. ▶ Products which are not in use must be stored in a dry, high place or locked away out of reach of children. ▶ The product is not intended for use by children. ▶ Observe the national health and safety requirements.

2.1.3 Proper preparation of the working area ▶ Avoid unfavorable body positions when working from ladders. Make sure you have a safe stance and that you stay in balance at all times. ▶ Secure the site at which you are taking measurements and take care to avoid directing the laser beam toward other persons or toward yourself. ▶ When the product is brought into a warm environment from very cold conditions, or vice-versa, allow it to become acclimatized before use. ▶ Use the product only within its specified limits. ▶ Keep the laser exit window clean in order to avoid measurement errors. ▶ Observe the accident prevention regulations applicable in your country.

2.1.4 Working safely with laser tools ▶ Laser Class 2/Class II tools may be operated only by appropriately trained persons. ▶ Laser beams should not be projected at eye height. ▶ Precautions must be taken to ensure that the laser beam does not unintentionally strike highly reflective surfaces. ▶ Precautions must be taken to ensure that persons do not stare directly into the beam. ▶ The laser beam must not be allowed to project beyond the controlled area. ▶ Switch the laser tool off when it is not in use.

Page 9 of the Hilti Laser Range Meter (PD-E) user manual — 3 Description
Page 9 · click to enlarge
Page 9

▶ Store laser tools, when not in use, in places to which unauthorized persons have no access.

2.1.5 Electromagnetic compatibility Although the device complies with the strict requirements of the applicable directives, Hilti cannot entirely rule out the possibility of interference to the device caused by powerful electromagnetic radiation, possibly leading to incorrect operation. Check the accuracy of the device by taking measure- ments by other means when working under such conditions or if you are unsure. Likewise, Hilti cannot rule out the possibility of interference with other devices (e.g. aircraft navigation equipment). The tool complies with the requirements of class A; The possibility of interference occurring in a domestic environment cannot be excluded. Only for Korea: This laser range meter is suitable for commercial and industrial use and for the electromagnetic radiation encountered in this field (Class A). Users must pay attention to this point and make sure that this laser range meter is not used in occupied living areas.

3 Description

3.1 Overview of the product 1 @ Rear contact surface ; Reference indicator LED for rear contact = Left arrow button % Menu button & “Measure” button ( Graphic display ) Reference indicator LED for front contact + Side “Measure” button

§ On/off button / Right arrow button : Hand strap attachment point ∙ Delete (clear) button $ ¹/₄ inch thread £ Folding spike | Laser emitting and receiving lens ¡ Optical sight Q ¹/₄ inch thread

3.2 Intended use

The product described is a laser range meter. It is designed for taking indi- vidual measurements as well as the continuous measurement of distances. Distances can be measured from all stationary targets without a highly reflective surface, i.e. concrete, stone, wood, plastic, paper, etc. The use of prisms or other highly reflective targets is not permissible and, if attempted, may falsify the results. The product is approved for use with batteries of the type AAA.

Page 10 of the Hilti Laser Range Meter (PD-E) user manual — 3.3 Explanation of the display
Page 10 · click to enlarge
Page 10
Hilti Laser Range Meter (PD-E) — 3.3 Explanation of the display diagram (page 10)
Fig. 6 · 3.3 Explanation of the display
Select angle unit Determine painter’s area Single Pythagoras Measure areas and volumes Select special functions Select trapezoid function Select Pythagoras function At least one right angle is required for horizontal and diagonal distances. Select settings Measure indirectly No specific angle is required for measurements on non-moving objects such as walls.
Battery charge state Measuring spike not folded out Measuring spike folded out Measure Add distances Subtract distances Select Do not select Select measuring time Select calculator
Inclination in percent Metric units Imperial units Inclination in angular degrees
Page 11 of the Hilti Laser Range Meter (PD-E) user manual — 3.3 Explanation of the display
Page 11 · click to enlarge
Page 11
Hilti Laser Range Meter (PD-E) — 3.3 Explanation of the display diagram (page 11)
Fig. 7 · 3.3 Explanation of the display
Measure rectangular areas Measure triangular areas Measure volumes Measure cylinder volume
Select outdoor mode Select automatic brightness sensor Determine area to be painted Select layout function Select min/max delta function Select timer Select offset function Select data storage media
Unit of measurement. Select unit of measurement: meter centimeter millimeter Measuring references. Select measuring reference: front edge rear of thread underside of thread Angle unit. Select angle unit: inclination in percent metric units imperial units inclination in angular degrees Select expert mode Edit favorites list
Page 12 of the Hilti Laser Range Meter (PD-E) user manual — 3.4 Items supplied
Page 12 · click to enlarge
Page 12
Hilti Laser Range Meter (PD-E) — 3.4 Items supplied diagram (page 12)
Fig. 8 · 3.4 Items supplied
Activate scale Switch signal tone on / off Select laser on constantly Select automatic brightness sensor Calibrate inclination sensor Display information about the tool Reset to default settings
Indirect horizontal distance measurement Indirect vertical distance measurement Take measurements on ceilings Indirect vertical distance measurement II

Laser range meter, two batteries, operating instructions, manufacturer’s certificate.

Other system products approved for use with this product can be found at your local Hilti Store or at: www.hilti.group

Rated voltage3 V Rated current400 mA Maximum site elevation above datum2,000 m (6,561 ft - 10 in) Maximum relative humidity80 % Operating temperature−10 ℃… 50 ℃ (14 ℉… 122 ℉) Distance measurement accuracy (2σ, standard deviation)±1.0 mm Inclination measurement accuracy (2σ, standard deviation)±0.2° Output power, laser< 1 mW Wavelength, laser639 nm (0.0000252 in)
Page 13 of the Hilti Laser Range Meter (PD-E) user manual — 5 Operation
Page 13 · click to enlarge
Page 13

Pulse duration < 3.6 ns Pulse period 8.3 ns … 243 ns Weight (including batteries) 165 g (5.8 oz) Storage temperature −30 ℃… 70 ℃ (−22 ℉… 158 ℉) Laser class in accordance with EN 60825- 1:2007 Laser class 2

Protection class in accordance with IEC 60529 IP 65

5 Operation

5.1 Basic functions

Navigate to the desired function with the aid of the left or right arrow buttons. ▶ Always press the “Measure” button to select a function.

5.2 Inserting the batteries 2

Take care to ensure correct battery polarity. Change the batteries only in pairs. Do not use damaged batteries.

▶ Open the battery compartment and insert the batteries.

5.3 Switching the laser range meter on and off

1. If the tool is switched off, press the on/off button or the “Measure” button to switch it on. 2. If the tool is switched on, press the on/off button to switch it off.

5.4 Measuring using the spike 3

1. Fold out the spike through 90°. The spike can then be used as the contact point.

Here, the spike helps to align the device while a stable position is established. This is the case primarily for indirect, trapezoid and Pythagoras measurements since these results are based on estimated values. Use the measuring extension PDA 72 for inaccessible places. The device automatically detects the measuring extension. A confirmation window may appear in the display.

2. Fold out the spike through 180°. The measuring reference point is then set automatically.
Page 14 of the Hilti Laser Range Meter (PD-E) user manual — 5.5 Measuring using a target plate
Page 14 · click to enlarge
Page 14

5.5 Measuring using a target plate 4

1. Use the target plate to measure distance under the following unfavorable conditions: ▶ The wall is not sufficiently reflective due to the type of surface. ▶ The target point is not on a surface. ▶ The distance to be measured is very long. ▶ The light conditions are unfavorable (bright sunshine). 2. A distance of 1.2 mm should be added to the measured distance when using a target plate.

5.6 Measurement mode

5.6.1 Single measurements 1. Press the “Measure” button briefly to activate the laser beam. 2. Keep the laser beam on the target point. 3. Press the “Measure” button briefly to take the measurement. ▶ The measured distance is shown in the lower line of the display. ▶ The distance measured in the previous measurement is shown in the upper line of the display. 4. To take another measurement, keep the laser beam on the target point and press the “Measure” button again.

5.6.2 Continuous measurement

During continuous measurement, 6-10 measurements are taken and displayed every second. The laser range meter can be moved relative to the target until the desired distance is reached.

1. Press the “Measure” button for 2 seconds. ▶ If the signal tone is active, a signal tone will be emitted. 2. Move the laser range meter toward or away from the target until the desired distance is reached. 3. Press the “Measure” button briefly. ▶ The measured distance is shown in the lower line of the display. ▶ The distance measured in the previous measurement is shown in the upper line of the display.

5.7 Selecting the angle unit

1. Select the angle unit symbol from the menu. 2. Navigate to the desired angle unit with the aid of the left or right arrow buttons. 3. Select the desired angle unit by pressing the “Measure” button.
Page 15 of the Hilti Laser Range Meter (PD-E) user manual — 5.8 Measuring areas and volumes
Page 15 · click to enlarge
Page 15

5.8 Measuring areas and volumes

5.8.1 Measuring rectangular areas 1. Aim the tool at the target point for the room width and press the “Measure” button. 2. Aim the tool at the target point for the room length and press the “Measure” button.

5.8.2 Measuring triangular areas 1. Aim the tool at the target point and press the “Measure” button. 2. Aim the tool at the target point and press the “Measure” button. 3. Aim the tool at the third target point and press the “Measure” button.

5.8.3 Measuring volumes 1. Aim the tool at the target point and press the “Measure” button. 2. Aim the tool at the next target point and press the “Measure” button. 3. Aim the tool at the next target point and press the “Measure” button.

5.8.4 Measuring cylindrical volume 1. Aim the tool at the corresponding target to measure the height of the cylinder and press the “Measure” button. 2. Aim the tool at the next target point to measure the diameter of the cylinder and press the “Measure” button.

5.9 Special functions

5.9.1 Automatic brightness sensor ▶ Select the symbol for the automatic brightness sensor from the special functions menu.

The automatic brightness sensor automatically dims the lighting on the display in dark surroundings. This saves battery power.

5.9.2 Painter’s area 1. Aim the tool at the target point for the first room length and press the “Measure” button. ▶ The result is saved as an intermediate result. 2. Aim the tool at the target for the next room length and press the “Measure” button to take the measurement. ▶ The second result is shown in the intermediate results table. The intermediate result shown in bold is the sum of the measured room lengths. 3. Repeat this procedure until all room lengths have been measured. 4. Press the right arrow button to switch to room height and confirm by pressing the “Measure” button.

Page 16 of the Hilti Laser Range Meter (PD-E) user manual — 5.9.3 Layout function
Page 16 · click to enlarge
Page 16
5. Position and aim the tool for room height measurement and then take the measurement. ▶ The room height is measured and displayed in the intermediate result line. The painter’s area is calculated immediately and shown in the result line.

5.9.3 Layout function 1. Enter the distance manually. Do this by using the left or right arrow buttons to select the keyboard symbol and confirm by pressing the “Measure” button. 2. Select the applicable numbers and confirm by pressing the “Measure” button. 3. To confirm the value, select the check mark symbol (tick) at the bottom right corner. 4. Select the flag symbol. ▶ The distance you have entered will then be shown between the two flags. 5. Press the “Measure” button to begin measuring. ▶ The arrows on the screen indicate in which direction you must move the tool. When the target distance is reached, black arrows appear above and below the distance shown in the display. 6. To repeat this distance measurement several times, move the tool further. The number of times you have measured out this distance is shown on the right of the screen. 7. Press the “Measure” button to stop measuring.

When the distance to be set out is reached, the currently used measuring reference is shown in the display.

As an alternative to entering the distance manually, the distance to be set out may also be measured with the tool. To do this, select the symbol for single measurement and confirm your choice by pressing the “Measure” button.

5.9.4 Min/max delta function 1. Select the symbol for the min/max delta function from the special functions menu. 2. Aim the tool at the target point and press the “Measure” button. 3. Press the “Measure” button to stop measuring. ▶ The last distances measured are shown in the results line.

Page 17 of the Hilti Laser Range Meter (PD-E) user manual — 5.9.5 Data storage
Page 17 · click to enlarge
Page 17

5.9.5 Data storage 1. Select the data storage symbol from the special functions menu.

The tool can save up to 30 screens, including the graphical symbols. If 30 screens have already been saved, the oldest one will be deleted automatically when a new screen is saved.

2. To delete data storage memory, press and hold the C-button for 2 seconds while the data storage screen is displayed.

5.10 Trapezoid

5.10.1 Trapezoid function (3 distances) 1. Select the symbol for the trapezoid function for 3 distances from the trapezoid functions menu. 2. Aim the tool at the target point and press the “Measure” button. ▶ After measuring the first distance, the graphical display automatically prompts you to take the next measurement. 3. Aim the tool at the next target point and press the “Measure” button. 4. Aim the tool at the third target point and press the “Measure” button.

5.10.2 Trapezoid with inclination (2 distances, 1 angle) 1. Select the symbol for the trapezoid function with inclination from the trapezoid functions menu. 2. Aim the tool at the target point and press the “Measure” button. 3. Aim the tool at the next target point and press the “Measure” button.

5.11 Pythagoras

5.11.1 Single Pythagoras 1. Aim the tool at the target point and press the “Measure” button. 2. Aim the tool at the next target point and press the “Measure” button.

In order to achieve accurate results, the second distance must be measured at right angles to the target distance.

5.11.2 Double Pythagoras 1. Aim the tool at the target point and press the “Measure” button. 2. Aim the tool at the next target point and press the “Measure” button.

In order to achieve accurate results, the second distance must be measured at right angles to the target distance.

3. Aim the tool at the third target point and press the “Measure” button.

5.11.3 Combined Pythagoras 1. Aim the tool at the target point and press the “Measure” button. 2. Aim the tool at the next target point and press the “Measure” button. 3. Aim the tool at the next target point and press the “Measure” button.

Page 18 of the Hilti Laser Range Meter (PD-E) user manual — 5.12 Settings
Page 18 · click to enlarge
Page 18

5.12 Settings

5.12.1 Editing the favorites list 1. Navigate to the function that you wish to edit and confirm by pressing the “Measure” button. 2. Navigate to the desired function and confirm by pressing the “Measure” button.

5.12.2 Activating the scale 1. Set the applicable number and confirm the value by pressing the “Measure” button. 2. Select the check mark symbol (tick) to confirm the value.

5.12.3 Calibrate inclination sensor 1. Place the tool on a horizontal surface and press the “Measure” button. 2. Rotate the tool through 180° and press the “Measure” button. ▶ The inclination sensor is now calibrated.

5.13 Indirect measurements

5.13.1 Indirect horizontal distance measurement ▶ Aim the tool at the target point and press the “Measure” button. ▶ The distance and angle of inclination are measured and shown in the intermediate result line. ▶ The target distance is calculated immediately and shown in the result line.

5.13.2 Indirect vertical distance (2 angles, 2 distances) 1. Aim the tool at the target point and press the “Measure” button. ▶ The first distance and angle are measured and shown in the interme- diate result line. ▶ The graphical display automatically prompts you to measure the second distance. 2. Aim the tool at the next target point and press the “Measure” button. ▶ The target distance is calculated immediately and shown in the result line.

5.13.3 Taking measurements on ceilings 1. Aim the tool at the target point and press the “Measure” button. ▶ The first distance and angle are measured and shown in the interme- diate result line. ▶ The graphical display automatically prompts you to measure the second distance. 2. Aim the tool at the next target point and press the “Measure” button. ▶ The target distance is calculated immediately and shown in the result line.

Page 19 of the Hilti Laser Range Meter (PD-E) user manual — 7 Disposal
Page 19 · click to enlarge
Page 19

5.13.4 Indirect vertical distance II (2 angles, 1 distance) 1. Aim the tool at the target point and press the “Measure” button. ▶ The first distance and angle are measured and shown in the interme- diate result line. ▶ The graphical display automatically prompts you to measure the second distance. 2. Aim the tool at the next target point and press the “Measure” button. ▶ The target distance is calculated immediately and shown in the result line.

6 Care, transport and storage

6.1 Cleaning

▶ Do not touch the lens with the fingers. ▶ Clean the lens by blowing the dust off or by wiping with a clean, dry cloth. ▶ Do not use liquids other than pure alcohol or water.

6.2 Transport

The batteries must be insulated or removed from the product before it is shipped or sent by mail.

▶ Use the Hilti packaging or packaging of equivalent quality for transporting or shipping your equipment.

6.3 Storage and drying

▶ Do not put the product into storage when wet. Allow it to dry before putting it away. ▶ Observe the temperature limits given in the Technical Data section which are applicable to storage or transport of the equipment. ▶ Check the accuracy of the equipment before it is used after a long period of storage or transportation.

7 Disposal

WARNING Risk of injury. Hazards presented by improper disposal. ▶ Improper disposal of the equipment may have the following conse- quences: The burning of plastic components generates toxic fumes which may present a health hazard. Batteries may explode if damaged or exposed to very high temperatures, causing poisoning, burns, acid burns or environmental pollution. Careless disposal may permit unau- thorized and improper use of the equipment. This may result in serious personal injury, injury to third parties and pollution of the environment.

Page 20 of the Hilti Laser Range Meter (PD-E) user manual — 9 Manufacturer’s warranty
Page 20 · click to enlarge
Page 20

Most of the materials from which Hilti products are manufactured can be recycled. The materials must be correctly separated before they can be recycled. In many countries, your old tools, machines or appliances can be returned to Hilti for recycling. Ask Hilti Service or your Hilti representative for further information. In accordance with the European Directive on waste electrical and electronic equipment and its implementation in conformance with national law, electric tools or appliances that have reached the end of their life must be collected separately and returned to an environmentally compatible recycling facility.

▶ Disposal of electric tools or appliances together with household waste is not permissible.

8 FCC statement / IC statement

CAUTION This product has been tested and found to comply with the limits for a class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. These products generate, use and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause interference to radio communications. There is no guarantee that interference will not occur in a particular instal- lation. If this product does cause harmful interference to radio or television reception, which can be determined by turning the product off and on, the user is encouraged to try to correct the interference by taking the following measures: ▶ Re-orient or move the receiving antenna. ▶ Increase the distance between the product and receiver. ▶ Connect the product to a power outlet on a circuit different from that to which the receiver is connected. ▶ Consult your dealer or an experienced TV/radio technician for assistance. Changes or modifications not expressly approved by Hilti may restrict the user’s right to operate the product. This product complies with the requirements in Paragraph 15 of the FCC Rules and RSS 210 of IC. Operation of the product is subject to the following conditions: ▶ This product should cause no harmful interference. ▶ This product must accept any interference received, including interfer- ence that may cause undesired operation.

9 Manufacturer’s warranty

▶ Please contact your local Hilti representative if you have questions about the warranty conditions.

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Hilti Laser Range Meter (PD-E)

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Hilti Laser Range Meter (PD-E)

Be the first to ask — other owners or our team will answer.

Original document

Hilti Laser Range Meter (PD-E) manual PDF

76 pages·420 KB·Power Tools·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…