FF1DNE
FAN COIL UNITS
Sizes 018, 024, 030
The FF1DNA and FF1DNE Fan Coil units are designed as upflow indoor air handlers for split-system heat pumps and air conditioners. They are available with factory- or field-installed electric heaters both of which include the disconnect. A field- installed cooling control with disconnect is also available. A TDR (Time Delay Relay) is included with either the electric heat or the cooling control packages. The FF1DNE models are avail- able with a factory installed TXV. This fan coil may be installed free standing, wall hung or flush mounted in the wall. The 22-in. wide cabinet size in all models allows units to fit between standard stud spacings. No return air ductwork is required if the application provides for return air in the front of the cabinet through either a louvered closet door or an optional accessory decorative grille panel. The cabinet exterior is made of pre-painted galvanized sheet metal. The cabinet is fully insulated to meet applications in con- ditioned space. Additional insulation is required if the unit is installed in an unconditioned space. Unit is supplied with replaceable filter. Multispeed direct-drive PSC blower motors have been selected to provide the proper air handling for both heating and cooling. Motors are suspended at 3 points on rubber grommets for qui- eter operation. All refrigerant lines, electrical power, and thermostat wiring enter from the top of the cabinet. Sweat-type refrigerant con- nections on both liquid and suction lines make for swift, low-cost installation. All service access to the unit is conveniently located in the front. The CHECK-FLO-RATER
piston ensures efficient and dependable refrigerant metering, and eliminates potential ser- vice requirements of other metering devices. The CHECK-FLO- RATER
is located inside the unit, easily accessible for piston maintenance or changeout. In addition, units can be factory ordered with a hard shut-off thermostatic expansion valve (TXV) metering device for perfor- mance improvement. The drain pan is constructed of high-impact, sound-deadening, corrosion-proof polyester resin. Primary and secondary drain connections exit from the bottom or either side of the cabinet.
® · ®

Electric Heater (kw) 000 005 075 011
Nominal Capacity (Btu) 018—18,000 024—24,000 030—30,000

E
D
T
O
A
R
F
E
D
T
O
A
R
E
R
T
A
S
E
R
T
A
S
U
R
E
R
Y
A
R
O
O
M
P
U
R
E
R
Y
H
E
O
M
P
T
T
A
R
N
D
T
Y
T
T
A
R
A
T
P
U
Y
U
F
A
U
N
O
N
N
G
U
F
A
U
N
M
P
N
G
N
M
A
G
N
W
T
N
M
A
W
T
H
A
E
Q
U
P
M
E
N
T
A
E
Q
U
P
M
E
N
T
S
T
A
N
D
A
R
D
R
S
T
A
N
D
A
R
D
CERTIFICATION APPLIES ONLY WHEN THE
COMPLETE SYSTEM IS LISTED WITH ARI.
Rough-in dimensions are 38-1/4 x 22-1/4 inches.
A minimum clearance of 21 in. is required in front of the access panels for servicing. Please note that this clearance is recommended for servicing only. Installation clearances from combustible materials are: 0 in. from cabinet and supply-air duct (plenum included). Leave adequate room for the condensate pan and refrigerant line connection.
22-3/4 to 24-in. on-center between-studs and 38-1/8 to 36-3/4-in. top-to-bottom inside-studs spacing.


LOW VOLTAGE ENTRY ( 7⁄8″ DIA. HOLE)
POWER ENTRY 1 3⁄8″ DIA. KNOCKOUT 7⁄8″ DIA. HOLE
2 13⁄16″ 2 7⁄16″ 2 3⁄8″
1 5⁄8″ 5 3⁄16″ 1 9⁄16″
8 1⁄4″ 4 3⁄16″
SUCTION, 018, 024, 030 - 3⁄4″ I.D. SWEAT LIQUID, 3⁄8″ I.D. SWEAT CONDENSATE, 3⁄4″ NPT
11 1⁄16″ 9 7⁄16″

See notes on page 5.

* Rated in accordance with U.S. Government DOE test procedures and/or ARI Standard 210/240-94.
† Use copper wire only. Use 75°C in this application. When using non-metallic (NM) sheathed cable, wire size required should be based on that of 60°C con-
ductors, instead of wire sizes shown in table above per NEC 1996 Article 336-30. Length shown is as measured 1 way along wire path between unit and service panel for voltage drop not to exceed 2%. ‡ Check outdoor unit for required piston size. †† 018 Size with 11-kw heater not approved for use with heat pumps.

* Saturated suction leaving evaporator coil.
Sensible Heat Capacity (1000 Btuh)
Gross Cooling Capacity (1000 Btuh)
NOTES:

Leaving db = entering db —
sensible heat cap.
1.09 x CFM
Leaving wb = wb corresponding to enthalpy of air leaving coil (h
4.5 x CFM
Interpolation is permissible. Correction Factor = 1.09 x (1 – BF) x (db – 80)
= enthalpy of air entering coil.

* Heater capacities shown here are for the largest size fan coil unit, and they do include blower motor heat.

STATIC PRESSURE AND VOLTAGE
0.1 0.2 0.3 0.4 0.5 208V 230V 208V 230V 208V 230V 208V 230V 208V 230V
BLOWER MOTOR
SPEED
018 High 610 720 580 665 540 610 475 540 380 415 Low 480 580 450 545 415 500 375 430 320 340
024 High 895 985 860 955 825 915 785 865 730 805 Low 650 740 620 710 585 680 550 640 510 600
030 High 1160 1190 1105 1135 1050 1080 990 1020 935 960 Low 885 1025 870 985 835 940 810 890 770 840
Data reflects a dry coil, filter, and 11-kw electric heater installed.
AIR DELIVERY (CFM) 400 500 600 700 800 900 1000 1100
1-Element 5 kw 0.007 0.010 0.015 0.025 0.035 0.055 0.070 0.080
2-Element 7.5 & 11 kw 0.010 0.012 0.018 0.028 0.050 0.075 0.100 0.130
018 — 0.019 0.029 0.036 0.043 — — — 024 — — 0.030 0.039 0.051 0.062 0.076 — 030 — 0.058 0.070 0.082 0.091
Subtract the above pressure drop corrections from unit airflow data when that component or condition is used. The remaining external static pressure will be available for the duct system.
UNIT SIZE
CFM
Pressure 63 125 250 500 1000 2000 4000
FF1-018 600 0.25 64.7 60.7 56.7 53.7 51.7 49.7 45.7 FF1-024 800 0.25 66.0 62.0 58.0 55.0 53.0 51.0 47.0 FF1-030 1000 0.25 67.0 63.0 59.0 56.0 54.0 52.0 48.0
* Estimated sound power levels have been derived using the method described in the
1987 ASHRAE HVAC Systems & Applications Handbook,
Chapter 52, p. 52.7.
KFDCC0101DCC Cooling Control Package All
KFBLG0106LGL* Louvered Wall Panel with Frame All

Packaged Service Training programs are an excellent way to increase your knowledge of the equipment discussed in this manual, including:
Classroom Service Training plus "hands-on" the products in our labs can mean increased confidence that really pays dividends in faster troubleshooting, fewer callbacks. Course descriptions and schedules are in our catalog.
[ ] Packaged Service Training [ ] Classroom Service Training
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE
UNIT MUST BE INSTALLED IN ACCORDANCE
WITH INSTALLATION INSTRUCTIONS
Form PDS FF1D.18.2